Loading...
36 -244 7D19956SC_J4_16_FFDKeyBeam® 4.600d kmBeamEngine 4.6026 Materials Database 1418 7D19956SC - J4-16 FFD KATZ RESIDENCE - LOT 9 SOVEREIGN WAY, NORTHAMPTON, MA 9-11-13 4:29pm 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Stephen Carr Seven D Wholesale 145 Dividend Road Rocky Hill, CT 06067 (860) 278-7750 Member Data Description: A11 Member Type: Joist Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: L/480 live, L/240 total Dead Load: 15 PSF Deck Connection: Glued & Nailed Filename: A11_05 Other Loads Type (Description) Side Begin End Other Start End Dead Start End Category Point (PLF) Top 0' 4.63" 0 81 Live Point (PLF) Top 0' 4.63" 765 421 Snow Point (PLF) Top 0' 4.63" 27 10 Live Point (PLF) Top 0' 4.63" 10 4 Live 1 2 15 6 10 15 6 10 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall Steel 5.500" 1.750" 1934# -- 2 15' 6.625" Half-Wall Steel 5.250" 1.750" 543# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 444#(333plf) 1020#(765plf) 836#(627plf) 2 395#(296plf) 0#(0plf) 148#(111plf) Design spans 14' 9.625" Product: 9 1/2" RFPI-40S 16.0" O.C.PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2008.'# 2735.'# 73% 7.79' Total Load D+L Shear 543.# 1120.# 48% 0' Total Load D+L End Reaction 543.# 1120.# 48% 0' Total Load D+L TL Deflection 0.3691" 0.7401" L/481 7.79' Total Load D+L LL Deflection 0.2684" 0.3701" L/661 7.79' Total Load L Control: Pos. Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table