Loading...
36 -244 7D19956SC_G1_3_FFDKeyBeam® 4.600d kmBeamEngine 4.6026 Materials Database 1418 7D19956SC - G1-3 FFD KATZ RESIDENCE - LOT 9 SOVEREIGN WAY, NORTHAMPTON, MA 9-11-13 4:31pm 1 of 2 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Stephen Carr Seven D Wholesale 145 Dividend Road Rocky Hill, CT 06067 (860) 278-7750 Member Data Description: G4 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 12.5 PLF Filename: G4_05 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 0' 10.63" 27 10 Live Replacement Uniform (PLF) Top 0' 0.00" 1' 5.13" 73 27 Live Replacement Uniform (PLF) Top 0' 10.63" 1' 10.63" 27 10 Live Replacement Uniform (PLF) Top 1' 5.13" 1' 10.63" 139 44 Live Replacement Uniform (PLF) Top 1' 10.63" 13' 4.63" 9 3 Live Replacement Uniform (PLF) Top 1' 10.63" 13' 4.63" 139 44 Live Replacement Uniform (PLF) Top 13' 4.63" 14' 10.63" 27 10 Live Replacement Uniform (PLF) Top 13' 4.63" 17' 4.63" 139 44 Live Replacement Uniform (PLF) Top 14' 10.63" 17' 4.63" 27 10 Live Point (LBS) Top 1' 10.63" 1851 1290 Live Point (LBS) Top 13' 4.63" 140 78 Live Point (LBS) Top 17' 0.00" 0 56 Live Point (LBS) Top 17' 0.00" 468 289 Snow Point (LBS) Top 17' 0.00" 1747 937 Live 1 2 17 4 10 17 4 10 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall Steel 5.250" 1.500" 4592# -- 2 17' 4.625" Wall Steel 5.500" 1.500" 5295# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 2910# 0# 1683# 2 3315# 468# 1980# Design spans 16' 7.625" Product: 2.0 RigidLam LVL 1-3/4 x 9-1/2 3 ply PASSES DESIGN CHECKS Connect members with 2 rows of 16d common nails at 12.0" oc NOTE: Nails must be applied from both sides NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 10170.'# 20436.'# 49% 7.85' Total Load D+L Shear 4474.# 9476.# 47% 0.37' Total Load D+L Max. Reaction 4592.# 20672.# 22% 0' Total Load D+L TL Deflection 0.7010" 0.8318" L/284 8.68' Total Load D+L LL Deflection 0.4740" 0.5545" L/421 8.68' Total Load L KeyBeam® 4.600d kmBeamEngine 4.6026 Materials Database 1418 7D19956SC - G1-3 FFD KATZ RESIDENCE - LOT 9 SOVEREIGN WAY, NORTHAMPTON, MA 9-11-13 4:31pm 2 of 2 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Stephen Carr Seven D Wholesale 145 Dividend Road Rocky Hill, CT 06067 (860) 278-7750 Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table