36 -244 7D19956SC_B1_3_FFDKeyBeam® 4.600d kmBeamEngine 4.6026 Materials Database 1418 7D19956SC - B1-3 FFD KATZ RESIDENCE - LOT 9 SOVEREIGN WAY, NORTHAMPTON, MA 9-11-13 4:33pm 1 of 2 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Stephen Carr Seven D Wholesale 145 Dividend Road Rocky Hill, CT 06067 (860) 278-7750 Member Data Description: B6 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: (See Below) Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 12.5 PLF Filename: B6_05 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 1' 10.69" 737 277 Live Replacement Uniform (PLF) Top 1' 10.69" 11' 5.75" 737 277 Live Replacement Uniform (PLF) Top 11' 5.75" 14' 0.00" 737 277 Live Replacement Uniform (PLF) Top 14' 0.00" 17' 11.75" 815 305 Live Replacement Uniform (PLF) Top 17' 11.75" 19' 7.75" 815 305 Live Replacement Uniform (PLF) Top 19' 7.75" 23' 2.75" 1046 392 Live Replacement Uniform (PLF) Top 23' 3.75" 26' 11.50" 27 10 Live Replacement Uniform (PLF) Top 23' 3.75" 26' 11.50" 307 115 Live Point (LBS) Top 0' 4.63" 4187 2229 Live Point (LBS) Top 19' 7.75" 3794 2352 Live Point (LBS) Top 23' 3.75" 2823 1662 Live Point (LBS) Top 26' 6.88" 0 81 Live Point (LBS) Top 26' 6.88" 425 213 Live 1 2 3 4 5 7 8 0 7 10 0 7 9 12 3 7 12 26 11 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall Steel 5.500" 2.486" 9788# -- 2 7' 8.000" Wall Steel 5.500" 2.235" 8801# -- 3 15' 6.000" Wall Steel 5.500" 3.236" 12743# -- 4 23' 3.750" Wall Steel 5.500" 4.498" 17709# -- 5 26' 11.500" Wall Steel 5.500" 1.500" 661# -2449# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 6687# 3101# 2 6641# 2159# 3 9003# 3740# 4 12008# 5701# 5 -1914# -534# Design spans 7' 3.375" 7' 10.000" 7' 9.750" 3' 3.125" Product: 2.0 RigidLam LVL 1-3/4 x 9-1/2 3 ply PASSES DESIGN CHECKS Connect members with 2 rows of 16d common nails at 12.0" oc NOTE: Nails must be applied from both sides Design assumes continuous lateral bracing along the top chord. No lateral bracing required along the bottom chord. Review gravity uplift reaction force of 2450lbs at bearing 5 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 12604.'# 20436.'# 61% 19.65' Odd Spans D+L Negative Moment 11207.'# 20436.'# 54% 23.31' Adjacent 3 D+L Negative Unbrcd 11207.'# 20436.'# 54% 23.31' Adjacent 3 D+L KeyBeam® 4.600d kmBeamEngine 4.6026 Materials Database 1418 7D19956SC - B1-3 FFD KATZ RESIDENCE - LOT 9 SOVEREIGN WAY, NORTHAMPTON, MA 9-11-13 4:33pm 2 of 2 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Stephen Carr Seven D Wholesale 145 Dividend Road Rocky Hill, CT 06067 (860) 278-7750 Actual Allowable Capacity Location Loading Shear 7991.# 9476.# 84% 22.53' Adjacent 3 D+L Max. Reaction 17709.# 23133.# 76% 23.31' Adjacent 3 D+L TL Deflection 0.1248" 0.3906" L/751 19.41' Odd Spans D+L LL Deflection 0.0875" 0.2604" L/999+ 19.41' Odd Spans L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 %