18-073_permitNORTHAMPTON, MASSACHUSETTS 01060 Renovation for: GI001 TITLE SHEET GI002 INFORMATION SHEET AD101 DEMOLITION PLAN A101 FLOOR PLAN A151 REFLECTED CEILING PLAN A201 INTERIOR ELEVATIONS, WALL TYPES, DOOR, WINDOW, AND ROOM FINISH SCHEDULE BUILDING CODES AND STANDARDS GENERAL NOTES INDEX TO DRAWINGS CONSTRUCTION CLASSIFICATION OCCUPANCY CLASSIFICATION APPLICABLE CODES & STANDARDS 1.MASSACHUSETTS STATE BUILDING CODE (780 CMR); 9TH EDITION 2.INTERNATIONAL EXISTING BUILDING CODE (IEBC); 2015 EDITION 3.INTERNATIONAL MECHANICAL CODE (IMC); 2015 EDITION 4.MASSACHUSETTS PLUMBING & FUEL GAS CODE (248 CMR) 5.PORTIONS OF THE INTERNATIONAL FIRE CODE (IFC); 2015 EDITION 6.NFPA 101 LIFE SAFETY CODE; 2015 EDITION 7.INTERNATIONAL ENERGY CONSERVATION CODE (IECC); 2015 EDITION 8.MASSACHUSETTS ARCHITECTURAL ACCESS BOARD REGULATIONS (521 CMR) 9.MASSACHUSETTS ELECTRIC CODE (527 CMR) B - BUSINESS TYPE 5B 1.THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR ALL WORK THAT IS SHOWN ON THE CONTRACT DRAWINGS THAT IS NOT SPECIFICALLY IDENTIFIED TO BE THAT OF A SUB-CONTRACTOR, INCLUDING ALL WORK THAT IS DESCRIBED BY THE CONTRACT DOCUMENTS THAT IS NOT IDENTIFIED AS BEING ANY SPECIFIC CONTRACTOR'S RESPONSIBILITY. THE SCOPES OF WORK OF THE INDIVIDUAL FIELD SUB-CONTRACTORS ARE IDENTIFIED IN THEIR RESPECTIVE SPECIFICATION SECTIONS. 2.THE GENERAL CONTRACTOR WILL PROVIDE BARRICADES, TEMPORARY LIGHTS, TEMPORARY TELEPHONE SERVICE, AND CLEAN-UP SERVICE TO THE WORK AREA. 3.THE GENERAL CONTRACTOR WILL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE PRIOR TO PROCEEDING WITH THE WORK. THE GENERAL CONTRACTOR WILL COORDINATE WORK ACCORDINGLY WITH ALL SUBCONTRACTORS AND THE OWNER. 4.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE AND THOROUGH CLEAN-UP AT THE END OF THE JOB, AND FOR DAILY REMOVAL OF CONSTRUCTION DEBRIS AND CLEAN-UP. 5.THE GENERAL CONTRACTOR WILL PERFORM MINOR SPACKLING AND REPAIRS TO EXISTING WALLS THROUGHOUT THE WORK AREA, AS IS REQUIRED IN PREPARATION FOR NEW FINISHES. 6.IT WILL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY AND EXECUTE ALL WORK IN ACCORDANCE WITH THE APPLICABLE STATE BUILDING CODE, CURRENT EDITION, WITH ALL OF ITS REFERENCED PUBLICATIONS AND ALL OTHER APPLICABLE STATE, FEDERAL, AND LOCAL CODES AND REGULATIONS. 7.IT WILL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO SEE THAT ALL WORK PERFORMED IS IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION'S LIFE SAFETY CODE (NFPA 101), CURRENT EDITION. 8.THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS APPLICABLE TO THE SCOPE OF WORK, AS REQUIRED BY THE OWNER, AND AS REQUIRED FOR REGULATORY COMPLIANCE. 9.THE GENERAL CONTRACTOR WILL PROVIDE THE OWNER WITH INSURANCE CERTIFICATES FOR THE REQUIRED INSURANCES PRIOR TO STARTING THE WORK. 10.THE GENERAL CONTRACTOR WILL FILE FOR AND SECURE ALL APPROVALS, PERMITS, AND CERTIFICATES OF COMPLIANCE AS REQUIRED. 11.THE GENERAL CONTRACTOR SHALL FULLY COMPLY WITH THE OWNER'S "INTERIM LIFE SAFETY POLICY" DURING THE ENTIRE CONSTRUCTION PERIOD. 1st FLOOR TENANT SPACE UNIT 1NW / 1NE COOLEDGE CENTER LLC 47 PLEASANT STREET 10/29/2018 11:36 AMTITLE SHEET GI001 GS SEAL: MARK DATE ISSUE -10/29/2018 PERMIT SET PROJECT NO: PROJECT ARCHITECT: PROJECT MANAGER: DRAWN BY: DATE: COPYRIGHT: 18-073 REK REK 10/29/2018 SHEET TITLE: CONSULTANT: 64 GOTHIC STREET, SUITE 1 NORTHAMPTON, MA 01060 T 413.585.1512 F 413.586.7945 www.haiarchitecture.com H AI Architecture, Inc. 1st Floor Tenant Space Unit 1NW/1NE Cooledge Center LLC 47 Pleasant Street Northampton, MA 01060 Renovation for: PROJECT: ZONING DISTRICT: PRINCIPAL USE: ZONING RESTRICTIONS RELATIVE TO USE: NOT APPLICABLE PARKING REQUIREMENTS: NOT APPLICABLE ADDITIONAL REQUIREMENTS: NOT APPLICABLE INTERIOR ELEVATION DESIGNATION DETAIL IDENTIFICATION SECTION DESIGNATION ROOM AND NAME NUMBER DOOR NUMBER KEY NOTE WALL TYPE HEIGHT MARK DETAIL DESIGNATION 15"-48"MIN. MAX.17"-25"36" MAX.TO SPOUT OUTLET27" MIN.KNEE CLEARANCE48"MAX48"MAX.Per NFPA 72 the lens of the strobe shall be no less than 80" and no greater than 96" AFF. When clg heights don't allow for a min. height of 80", strobes shall be mounted within 6" of clg 17" MIN.34" MAX.TO RIMINSULATE ALL PLUMBING W/ TRUEBRO LAVATORY GUARD OR EQUAL FINISH FLOOR 15"-48"MIN MAX48"48" LINE FINISH FLOOR LINE The highest operable part of telephone, including dial, handset and coin deposit slots shall be within the reach ranges specified in ABA Section 30815"MINAccessible storage spaces shall be within at least one of the reach ranges specified in ABA Sections 308 29"MIN.27"MIN.40" MAX. TO BTMEDGE OF REFLECTINGSURFACEHIGHEST OPERABLE PART HIGHEST OPERABLE PART HIGHEST OPERABLE PART 15" - 42" DEPENDENTON FORWARD OR SIDE REACH36"x48" CLR. FLR. SPACE FIRE HORN AND LIGHT FIRE EXTINGUISHER CABINET PUBLIC TELEPHONE (ELEVATION) 30"x48" CLR. FLOOR SPACE FOR FORWARD APPROACH PUBLIC TELEPHONE (PLAN) CLOTHES HOOK/ROD DUPLEX RECEPTACLE LAVATORY (ELEV.)LAVATORY FORWARD APPROACH (PLAN) MIRROR DRINKING FOUNTAIN (PARALLEL APPROACH) FREE STANDING OR BUILT-IN UNITS DRINKING FOUNTAIN (FORWARD APPROACH) WALL & POST MOUNTED CANTILEVERED UNITS ACCESSIBLE DRINKING FOUNTAIN (ELEV.) MIN. SHOWER CONFIGURATION PLAN SOAP DISPENSER NAPKIN/TAMPON VENDOR PAPER TOWEL DISPENSER20"MAX2'-0"MAX.80"-96" AFFFIRE ALARM PULL STATION42"-48"OPTIONAL POST OR BASE 4'-0"MAX.8" MIN.30"x48" CLR. FLOOR SPACE 30"x48" CLR. FLOOR SPACE6" MAX. TOE CLEARANCE 6" MAX. TOE CLEARANCE 15" - 42" DEPENDENTON FORWARD OR SIDE REACH15" - 42" DEPENDENTON FORWARD OR SIDE REACHNOTE: CONTROLS OF OPERATING MECHANISMS MUST BE PLACED WITHIN AT LEAST ONE OF THE REACH RANGES SPECIFIED IN UFAS SECTION 4.2.5 & 4.2.6 HIGHEST OPERABLE PART FOR FORWARDOR SIDE REACHFOR FORWARDAPPROACHFOR FORWARDAPPROACHSEE PLAN FORUNOBSTRUCTEDSIDE ORFORWARD REACH9" MIN.TOECLEARANCE17"MIN.SINK 5" MAX. 5" MAX. SPOUT LOCATION SPOUT LOCATION 15" MIN. 15" MIN.9" MIN.TOE CLEARANCE8" MIN. KNEE CLEARANCE MIRROR -REQUIRED CLEAR FLOOR SPACES, CLEARANCE AT FIXTURES AND TURNING SPACES SHALL BE PERMITTED TO OVERLAP. -DOOR SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE. 1 A101 A B C D 2 A102 1 A101 CONFERENCE ROOM 1005 201 2 CEILING HEIGHT EL. = 100'-0" 36 A101 EXIT REQUIREMENTS: OCCUPANCY LOAD: 2,800 SF @ 100 SF / OCCUPANT = 28 OCCUPANTS (SEE INTERNATIONAL BUILDING CODE TABLE 1004.1.1) MINIMUM EGRESS WIDTH CALCULATIONS (DOORS, RAMPS & CORRIDORS): MINIMUM EGRESS WIDTH CALCULATIONS (STAIRS): 2 EXITS REQUIRED; 3 EXITS PROVIDED (SEE INTERNATIONAL BUILDING CODE TABLE 1021.1) CORRIDORS: 44" MIN. REQUIRED, 60" PROVIDED (SEE INTERNATIONAL BUILDING CODE 1018.2) DOORS: 36" MIN. REQUIRED, 36" PROVIDED (SEE INTERNATIONAL BUILDING CODE 1005.1) NOT APPLICABLE EYE/FACE WASH (SIDE ELEV.)27" MIN.KNEE CLEARANCE36" MAX.SPRAY HEADCLEARANCE48" MAX. HEIGHTFOR FORWARD REACH30"x48" CLR. FLOOR SPACE EYE/FACE WASH (PLAN) PAPER TOWEL DISPENSER AND WASTE RECEPTACLE4'-0"MAX.HIGHEST OPERABLEPARTFOLD DOWN SEAT AS REQUIRED FRONT ELEV. BABY CHANGING STATION SIDE ELEV.PLAN48"MAXTO OPERABLEPORTION34"MAX.TO HIGHEST PART OF WORKSURFACE IN DOWN POSITION27"MIN.TO BOTTOM OF WORKSURFACE30"x48" MIN. 17" - 25" TOE CLEARANCE 30" OR WIDTH OF TABLE 48"25"OR LESS44" MAXLATCH33"-36"MIN. MAX.7"-9" MIN. MAX.15"-48"MIN. MAX.12" MAX.42" MIN.12" MIN.33"-36"MIN. MAX.FINISH FLOOR LINE 13-1/2" MIN. Mount on side wall closest to water closet; shall not be located behind grab bar Grab bars shall be between 1-1/4" and LQ™DQGORFDWHGFOHDU from wall 17"-19"MIN. MAX.18" TOILET TISSUE DISPENSER/HOLDER TOILET CLOSEST SIDE WALL GRAB BARS (ELEV.) TOILET REAR WALL GRAB BARS (ELEVATION) TOILET (SIDE ELEVATION) Flush controls shall be located on the open side of water closet or directly behind the toilet. TOILET (FRONT ELEVATION) URINAL (ELEVATION) URINAL (PLAN) 36" MIN. 24" MIN. OPEN SIDE 54" MIN. TRANSFER SIDE SIDE WALL 17" MAX.TO RIM44" TYP.FLUSH CONTROLSW/IN REACH RANGEABA SECTION 308CLEARANCE AT TOILET (PLAN) 5'-6" MIN.6'-0"MIN.18" 30"x48" CLR. FLOOR SPACE 6'-0" X 5'-6" MIN. CLEAR FLOOR SPACEPREFERRED LOCATION IS BELOW GRAB BAR @ 2'-0" A.F.F. TO CENTER OF DISPENSER 6" MIN.33"-36"MIN. MAX.TOILET REAR WALL GRAB BARS (ELEV.) 3'-6" MIN. 3'-0" MIN.OPEN SIDE ȭ TRANSFER SIDE SWING-UP GRAB BAR W/ INTEGRAL TOILET PAPER DISPENSER (ELEV.) CIRCULAR SPACE T-SHAPED SPACE This space shall be permitted to include knee and toe clearance complying with ABAAS Section 306 60" DIA. (MIN.)36"24"12"36"12" 60"60"This space shall be permitted to include knee and toe clearance complying with ABAAS Section 306 only at the end of the base or one arm NURSE CALL LIGHT6"EQ.EQ. CL CL NURSE CALL LIGHT; SEE ELEC. DWGS. 2'-5"3'-0"ANCHOR BOLT ACOUSTICAL AIR CONDITIONER ADJACENT ABOVE FINISH FLOOR ALTERNATE ALUMINUM ANCHOR ANODIZED ARCHITECT B.L. BD. BLDG. BLK. BLKG. B.O. A.B. ACOUST. A.C. ADJ. A.F.F. ALT. ALUM. ANCH. ANOD. ARCH. BTM. BRG. BRK. BUILDING LINE BOARD BUILDING BLOCK BLOCKING BOTTOM OF BOTTOM BEARING BRICK CONTRACTOR FURNISHED, CONTRACTOR INSTALLED CABINET CORNER GUARD CONTROL JOINT CLOSET CENTER CEILING CLEAR (DIMENSION) CONCRETE MASONRY UNIT COLUMN COMPACTED (COMPOSITION) CONCRETE CONSTRUCTION CONTINUOUS CONTRACTOR CERAMIC TILE DRINKING FOUNTAIN DIAMETER DIMENSION DOWN DOOR DETAIL DRAWINGS EAST EXTERIOR INSULATION & FINISH SYSTEM EXPANSION JOINT ELEVATION ELECTRICAL ELEVATOR EQUAL EQUIPMENT EMERGENCY ROOM EXISTING TO REMAIN ELECTRIC WATER COOLER EXHAUST EXISTING EXPANSION EXTERIOR FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FIRE HOSE CABINET FLOOR FINISH FACE OF FINISH FACE OF FOUNDATION WALL FACE OF MASONRY FACE OF STUD FIELD VERIFY GAUGE GALVANIZED GENERAL CONTRACTOR GLASS GENERAL GLAZE GRADE GYPSUM WALL BOARD HANDICAPPED HEIGHT HOLLOW METAL HOT WATER HEATER HEATING, VENTILATING AND AIR CONDITIONING INSIDE DIAMETER INSULATED HOLLOW METAL INSULATED STEEL INSULATION INTERIOR JANITOR JOIST JOINT KICKPLATE (HEIGHT") LAMINATE LAVATORY MASONRY MAXIMUM MECHANICAL MECHANICAL, ELECTRICAL, PLUMBING MANUFACTURER MOUNTED METAL MINERAL CORE MINIMUM MISCELLANEOUS MASONRY OPENING MULLION NORTH NATURAL NAPKIN DISPENSER NECESSARY NOT IN CONTRACT NOT TO SCALE ON CENTER OWNER FURNISHED, CONTRACTOR INSTALLED OWNER FINISHED, OWNER INSTALLED OPENING OPPOSITE PROPERTY LINE PARTICLE BOARD PLASTIC LAMINATE PLASTER PAINT PAINTED PARTITION POLYVINYL CHLORIDE PLYWOOD ROOF DRAIN REFERENCE REFRIGERATOR REINFORCE REQUIRED ROUGH ROOM ROUGH OPENING SOUTH SOLID CORE WOOD SECTION SQUARE FOOT SIMILAR SURFACE MOUNTED SPECIFICATIONS STAINLESS STEEL STANDARD STEEL STORAGE STRUCTURAL SUSPEND(ED) SYSTEM TEMPERED TOP OF TELEPHONE THICK TEMPERED INSULATED TOILET TYPICAL TOP OF FOUNDATION TOP OF WALL ELEVATION TOP OF STEEL ELEVATION TOP OF SLAB UNDER COUNTER REFRIGERATOR UNIT HEATER UNDERSIDE OF DECK UNLESS NOTED OTHERWISE URINAL VINYL BASE VINYL COMPOSITION TILE VERTICAL VESTIBULE VERIFY IN FIELD WEST WITH WITHOUT WITHIN WATER CLOSET WOOD 1/4" WIRE GLASS 1/4" TEMPERED GLASS CAB. C.F.C.I. C.G. C.J. CL. CTR. CLG. CLR. CMU COL. COMP. CONC. CONST. CONT. CONTR. C.T. D.F. DIA. DIM. DN DR. DTL. DWGS. E E.I.F.S. E.J. EL. ELEC. ELEV. EQ. EQUIP. E.R. E.T.R. E.W.C. EXH. EX. EXP. EXT. F.D. FDN. F.E. F.E.C. F.H.C. FIN. FLR. F.O.F. F.F. F.O.M. F.O.S. F.V. GA. GALV. G.C. GEN. GL. GLZ. GRD. G.W.B. H.C. HGT. H.M. H.W.H. HVAC I.D. I.H.M. I.S. INSUL. INT. JAN. JST. JT. K(12) LAM. LAV. MAS. MAX. MECH. M.E.P. MFR. MTD. MTL. MIN MIN. MISC. M.O. MULL. N NAT. N.D. NEC. N.I.C. N.T.S. O.C. O.F.C.I. O.F.O.I. OPG. OPP. P.L. PBD. PLAM. PLAS. PT. PTD. PTN. PVC PLYWD. R.D. REF. REFR. REINF. REQ'D RGH. RM. R.O. S S.C.W. SECT. SF SIM. S.M. SPEC. S.S. STD. STL. STOR. STRUCT. SUSP. SYS. T. T.O. TEL. THK. T.I. TLT. TYP. T.O.F. T.O.W. T.O.S. T.SLB. U.C.REFR. U.H. U.O.D. U.N.O. UR. V.B. V.C.T. VERT. VEST. V.I.F. W W/ W/O W/IN W.C. WD. 1/4 W.G. 1/4 T. REFLECTED CEILING PLANRCP GOVERNMENT FURNISHED PROPERTY GFP ABBREVIATIONS FIXTURE AND MISC. ACCESSORIES HEIGHTS CODE ANALYSIS ZONING ANALYSIS GRAPHIC SYMBOLS ON SHEET WHERE DETAIL IS TAKEN; SHEET NUMBER WHERE DRAWN DETAIL DESIGNATION ON SHEET WHERE DETAIL IS TAKEN; SHEET NUMBER WHERE DRAWN DETAIL DESIGNATION ON SHEET WHERE SECTION IS TAKEN; SHEET NUMBER WHERE DRAWN SECTION DESIGNATION ELEVATION LETTER ON SHEET WHERE SECTION IS TAKEN; SHEET NUMBER WHERE DRAWN SECTION DESIGNATION 74" MIN. TO TOPEDGE OFREFLECTINGSURFACE30"x48" CLEAR FLOOR SPACE 10/29/2018 11:37 AMINFORMATION SHEET GI002 GS SEAL: MARK DATE ISSUE -10/29/2018 PERMIT SET PROJECT NO: PROJECT ARCHITECT: PROJECT MANAGER: DRAWN BY: DATE: COPYRIGHT: 18-073 REK REK 10/29/2018 SHEET TITLE: CONSULTANT: 64 GOTHIC STREET, SUITE 1 NORTHAMPTON, MA 01060 T 413.585.1512 F 413.586.7945 www.haiarchitecture.com H AI Architecture, Inc. 1st Floor Tenant Space Unit 1NW/1NE Cooledge Center LLC 47 Pleasant Street Northampton, MA 01060 Renovation for: PROJECT: COMMON MEN'STOILETCOMMONHALLWAYREAR COMMONENTRYFRONT COMMONENTRYELEVATORCOMMON WOMEN'STOILETOPENSPACEE.P.DNDNRAMP DNDN DNUPE.P.IT PANEL PLEASANT STREET E.P.OFFICEOFFICERECEPTIONAREAOFFICEOFFICEOFFICEOFFICEOFFICEOFFICEITROOMOPENSPACEOFFICEOWNER'SITUPDNCOMMONHALLWAYOPENSPACEE.P.E.P.F.E.F.E.RADIATOR FDEMOLITION PLANSCALE: 1/4" = 1'-0"3232323283283232832RELOCATEEXISTING DOOR10REMOVE EXISTING MEDICAL GAS LINES, VALVES, ACCESSORIES, ETC. FROM ALL WALLS OR CEILINGSTHAT ARE SCHEDULED TO BE DEMOLISHED. REMOVE THE ASSOCIATED PLUMBING BACK TO THENEAREST APPROPRIATE CONCEALED AREA. PROVIDE VALVE AND CAP THE LINES. SEE PLUMBINGPLANS FOR FURTHER INFORMATION. COORDINATE WORK WITH THE OWNER.REMOVE EXISTING PLUMBING FIXTURES (SINK, WATER CLOSETS, SHOWERS, ETC.) AND ALLACCESSORIES. REMOVE ALL PLUMBING LINES (HOT AND COLD WATER, WASTE AND VENT) TONEAREST CONCEALED AREA (WALL, FLOOR, CEILING OR CHASE). PROVIDE VALVE AND CAP ATAPPROPRIATE SOURCE. COORDINATE WITH OWNER'S REPRESENTATIVE FOR ACCEPTABLE CAP ANDVALVE LOCATIONS. PATCH DISTURBED AREAS TO MATCH EXISTING AND NEW WORK. EXISTINGPLUMBING FIXTURES TO BE REMOVED SHALL BE REMOVED TO THE OWNER'S STORAGE.NOT USEDREMOVE ANY ELECTRICAL DEVICES, (OUTLETS, SWITCHES, LIGHT FIXTURES, CLOCKS, ETC.) WHEREREQUIRED TO ACCOMMODATE NEW CONSTRUCTION. ALSO REMOVE ALL RELATED WIRING ANDCONDUIT, EXCEPT WHERE THE CONDUIT IS SCHEDULED TO REMAIN FOR REUSE. REMOVE THECONDUIT AND WIRING BACK TO THE NEAREST CONCEALED AREA (WALL, FLOOR, CEILING OR CHASE)AND DISCONNECT THAT CIRCUIT FROM THE BUILDING'S POWER SYSTEM. SEE ELECTRICAL PLANSFOR EXACT LOCATIONS OF ELECTRICAL DEVICES TO BE REMOVED. PATCH AND REPAIR SURFACESAS REQUIRED TO MATCH EXISTING AND NEW WORK. EXISTING ELECTRICAL DEVICES AT EXISTINGWALLS TO REMAIN (TYPICAL)NOT USEDREMOVE EXISTING DOORS AND DOOR FRAMES AS SCHEDULED. PATCH AND REPAIR WALLS,FLOORS AND CEILINGS TO MATCH EXISTING AND NEW WORK AS SCHEDULED. RELOCATE ANDREFINISH/RECONDITION DOORS THAT ARE SCHEDULED TO BE RELOCATED IN THE DOORSCHEDULE.REMOVE EXISTING SUSPENDED ACOUSTICAL CEILING SYSTEM, INCLUDING ALL TILES, GRIDS,HANGERS, AND TRACKS. PATCH & REPAIR WALLS AS REQUIRED TO MATCH NEW & EXISTINGWORK TO REMAIN - REFER TO MEP DRAWINGS FOR ADDITIONAL ASSOCIATED ITEMS.NOT USEDNOT USEDNOT USEDWHERE EXISTING PARTITIONS, OR PORTIONS OF SAME, ARE REMOVED, TO ACCOMMODATENEW DOORS OR WINDOWS, COUNTERS, OR CABINETS BECAUSE OF DEMOLITION, PATCH ANDREPAIR WALLS, FLOORS, AND CEILINGS TO MATCH EXISTING AND NEW WORK AS SCHEDULED.WHERE EXISTING CMU WALLS ARE REMOVED TO ACCOMMODATE NEW DOORS OR WINDOWS,PROVIDE NEW LINTELS OVER THE OPENING AS REQUIRED. SEE LINTEL SCHEDULE. LEAVEJAMBS CLEAN AND SQUARE FOR APPLICATION OF NEW DOOR OR WINDOW FRAME.PROVIDE TEMPORARY DUSTPROOFING PARTITIONS AT ALL EXISTING AREAS THAT ABUT THEWORK AREA AND WHERE INDICATED ON THE DRAWINGS. TEMPORARY PARTITIONING SHALL BELOCKABLE, AND SHALL EXTEND FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE. SEEDRAWINGS FOR LOCATIONS. CONTRACTOR TO USE RIGID TEMPORARY PARTITION (MODULARSYSTEM) AS APPROVED BY OWNER.THE FOLLOWING DEMOLITION NOTES REFER ONLY TO THE GENERAL SCOPE OF DEMOLITION REQUIRED TOCOMPLETE THIS PROJECT, AND MAY NOT SPECIFICALLY IDENTIFY EACH AND EVERY COMPONENT OF ANARCHITECTURAL, MECHANICAL, OR ELECTRICAL SYSTEM OR ASSEMBLY (WHETHER DESIGNATED ON THEDEMOLITION PLAN (S) OR NOT). THE GENERAL CONTRACTOR AND HIS/HER SUBCONTRACTORS SHALL BEREQUIRED TO REMOVE/DEMOLISH INCIDENTAL ITEMS THAT MAY BE CONSTRUED TO BE RELEVANT TO THESCOPE OF DEMOLITION SHOWN ON THE DEMOLITION PLAN(S), OR REQUIRED TO COMPLETE THE NEW WORK.THE GENERAL CONTRACTOR SHALL BE REQUIRED TO DEMOLISH SPECIFIC ITEMS, WHETHER OR NOT THEY ARESPECIFICALLY INDICATED.THE GENERAL CONTRACTOR SHALL BE REQUIRED TO CUT ALL HOLES IN FLOORS, WALLS, CEILINGS, ETC. ASREQUIRED FOR MECHANICAL OR ELECTRICAL WORK IDENTIFIED IN THE CONTRACT DOCUMENTS (INCLUDING,BUT NOT LIMITED TO DUCTWORK, HYDRONIC PIPING, FIRE SUPPRESSION PIPING, PLUMBING PIPING, AND/ORELECTRICAL CONDUIT FOR POWER / DATA / LOW VOLTAGE / SPECIALTY SYSTEMS). GENERALLY, THESEPENETRATIONS ARE NOT SHOWN ON THE CONTRACT DRAWINGS; HOWEVER, THE GENERAL CONTRACTOR (ORAPPROPRIATE SUBCONTRACTOR) SHALL BE RESPONSIBLE FOR CORING OPERATIONS, AND SLEEVINGPENETRATIONS WHERE REQUIRED, WITH A MATERIAL THAT IS SUITED TO THE TYPE OF PENETRATION ANDRATING OF THE ASSEMBLY BEING PENETRATED. THE GENERAL CONTRACTOR SHALL BE REQUIRED TO PATCHAND REPAIR ALL DAMAGED SURFACES TO MATCH EXISTING AND/OR AS REQUIRED BY THE NEW WORK.1NOT USEDIF HAZARDOUS MATERIALS ARE ENCOUNTERED DURING DEMOLITION OPERATIONS, IMMEDIATELYNOTIFY OWNER AND COMPLY WITH ALL APPLICABLE REGULATIONS, LAWS, AND ORDINANCESCONCERNING REMOVAL, HANDLING AND PROTECTION AGAINST EXPOSURE OR ENVIRONMENTALPOLLUTION.REMOVE EXISTING STUD PARTITIONS, CMU OR BRICK OR PORTIONS OF SAME (INCLUDING ALLELECTRICAL DEVICES AND WIRING, PLUMBING FIXTURES AND PIPING AND ANY OTHER ITEMSMADE OBSOLETE BY THE REMOVAL OF THE PARTITION), CHASES, DOORS, FRAMES ANDMISCELLANEOUS CONSTRUCTION ITEMS. PATCH AND REPAIR WALLS, FLOORS, CEILINGS TOMATCH EXISTING AND NEW WORK AS SCHEDULED.REMOVE EXISTING FIRE PROTECTION PIPING AND HEADS AS REQUIRED TO SUIT NEW WORK.EXTEND AND/OR RECONFIGURE PIPING AS REQUIRED - SEE FIRE PROTECTION DRAWINGS FORFURTHER INFORMATION. COORDINATE ANY REQUIRED SHUT DOWNS WITH THE OWNER.234567891011121314151617REMOVE EXISTING HVAC DUCTWORK VALVES, CONTROLS, WIRING, THERMOSTATS, DUCTHANGERS, RADIATORS, RADIATOR ENCLOSURE COVERS AND ALL EQUIPMENT ACCESSORIES,ANY MISCELLANEOUS HVAC ACCESSORIES THAT REQUIRE REMOVAL WITH THE DEMOLITIONOF WALLS AND/OR CEILINGS. REMOVE THE DUCTWORK AND PIPING BACK TO THE NEARESTAPPROPRIATE CONCEALED AREA AND CAP THE DUCTS AND LINES IN QUESTION. PATCH ANDREPAIR SURFACES AS REQUIRED TO MATCH EXISTING AND NEW WORK AND MAINTAINREQUIRED FIRE RATINGS. SEE HVAC DRAWINGS FOR FURTHER INFORMATION. COORDINATEWITH OWNER'S REPRESENTATIVE FOR INFECTION CONTROL POLICIES.REMOVE EXISTING TEL/DATA LINES, RECEPTACLES, AND/OR DEVICES WHERE REQUIRED TOACCOMMODATE NEW CONSTRUCTION. ALSO REMOVE ALL RELATED WIRING AND CONDUIT, EXCEPTWHERE THE CONDUIT IS SCHEDULED TO REMAIN FOR REUSE. REMOVE THE CONDUIT AND WIRINGBACK TO THE NEAREST CONCEALED AREA (WALL, FLOOR, CEILING OR CHASE) SEE ELECTRICALPLANS FOR EXACT LOCATIONS OF TELE/DATA DEVICES TO BE REMOVED. PATCH AND REPAIRSURFACES AS REQUIRED TO MATCH EXISTING AND NEW WORK.DEMOLITION KEYNOTESTEMPORARY DUSTPROOFING PARTITIONEXISTING CONSTRUCTIONDEMOLITIONLEGENDTPTPTPXKEYED DEMOLITION NOTES10/29/2018 11:40 AM DEMOLITION PLAND101GSSEAL:MARKDATEISSUE-10/29/2018PERMIT SETPROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:18-073REKREK10/29/2018SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.1st Floor Tenant SpaceUnit 1NW/1NECooledge Center LLC47 Pleasant StreetNorthampton, MA 01060Renovation for:PROJECT: OFFICE #102, 103, 104 INTERIOR ELEVATION SCALE: 1/4" = 1'-0" 1 A101 BASE - SEE ROOM FINISH SCHEDULE C 010203 W1 W1 W1 BASE - SEE ROOM FINISH SCHEDULE D OPEN W1 W1 CONFERENCE ROOM #105 INTERIOR ELEVATION SCALE: 1/4" = 1'-0" 3 A101 BASE - SEE ROOM FINISH SCHEDULE A 04 W1 BASE - SEE ROOM FINISH SCHEDULE OPENW1W1W1 B4'-4"2'-10"4'-4"2'-10"4'-4"2'-10"4'-4"2'-10"4'-4"2'-10"4'-4"2'-10"4'-4"2'-10"ROOM #106 INTERIOR ELEVATION SCALE: 1/4" = 1'-0" 5 A101 BASE - SEE ROOM FINISH SCHEDULE D 05 W2 4'-4"2'-10"SEE SCHED. A 2" TYP.SEE SCHED.2" TYP.2"TYP.DOOR ELEVATIONS TEMPERED VISION PANEL SEE SCHED. 6" TYP.10"2"TYP.SEE SCHED.2" TYP. 2" TYP.10"B W1 WINDOW ELEVATIONS W1 4'-4"2'-10"4'-4"2'-10"W2 2"4'-0"2"2"4'-0"2"3'-0"1'-4" 2"1'-0"2"2"2"2'-8" 1/4" TEMPERED GLASS 1 WALL TYPE SCALE: 1" = 1'-0" FLOOR LINE 5/8" TYPE "X" GYPSUM BOARD (EACH SIDE) 3-5/8" METAL STUDS @ 16" O.C. BATT SOUND INSULATION NON-RATED WALL BASE - SEE ROOM FINISH SCHEDULE CEILING SEE R.C.P. LINE OF STRUCTURAL DECK OR SLAB ABOVE USE MOISTURE RESISTANT GYPSUM BOARD FOR ALL WET AREAS 2 WALL TYPE SCALE: 1" = 1'-0" FLOOR LINE 5/8" TYPE "X" GYPSUM BOARD (EACH SIDE) 3-5/8" METAL STUDS @ 16" O.C. BATT SOUND INSULATION CAULK & SEAL (BOTH SIDES) CAULK & SEAL (BOTH SIDES) 1 HOUR RATED WALL / UL DES U465 BASE - SEE ROOM FINISH SCHEDULE CEILING SEE R.C.P. LINE OF STRUCTURAL DECK OR SLAB ABOVE USE MOISTURE RESISTANT GYPSUM BOARD FOR ALL WET AREAS 3 WALL TYPE SCALE: 1" = 1'-0" FLOOR LINE 5/8" TYPE "X" GYP. BD. (EACH SIDE) EXISTING WALL CONSTRUCTION 3-5/8" METAL STUDS @ 16" O.C. WITH BATT SOUND INSULATION CAULK & SEAL (BOTH SIDES) BASE - SEE ROOM FINISH SCHEDULE ALIGN ALIGN CEILING SEE R.C.P. LINE OF STRUCTURAL DECK OR SLAB ABOVE NON-RATED WALL USE MOISTURE RESISTANT GYPSUM BOARD FOR ALL WET AREAS - DOOR SCHEDULE DOOR DOOR FRAME REMARKS (SEE DOOR NOTES)HDWRLBLMATLSILLJAMB DETAIL HEADLFSGLAZLBLMATLSIZEELEV.MARK 02 A 3'-0"x 7'-0"x 1-3/4"SCW HM---1 NOTE: 1. ALL DOOR HANDLES SHALL BE OF LEVER TYPE MEETING CURRENT ADA STANDARDS, (AS NOTED IN THE HARDWARE SCHEDULE). DOOR HANDLES TO ROOMS CONSTITUTING A HAZARD (ELECTRICAL ROOMS, MECHANICAL ROOMS, SOILED UTILITY ROOMS, ETC.) SHALL BE LEVER TYPE WITH A KNURLED FINISH ON THE GRIP SURFACE. 2. ALL LOCKSETS & LATCHSETS SHALL BE OF MORTISE DESIGN. 3. ALL HARDWARE FINISH SHALL BE BRUSHED STAINLESS STEEL (US32D). 4. ALL PRODUCTS SPECIFIED ON AN 'OR EQUAL' BASIS UNLESS OTHERWISE NOTED. 5. PROVIDE REQUIRED POWER SUPPLY SYSTEMS FOR OPERATING ALL ELECTROMAGNETIC LOCKS, ELECTROMECHANICAL LOCKS, ELECTRIC STRIKES, & MARLOK ELECTRONIC CYLINDER SYSTEMS. COORDINATE REQUIREMENTS WITH E.C. 6. ALL ELECTROMAGNETIC LOCKS, ELECTROMECHANICAL LOCKS, & ELECTRIC STRIKES SHALL BE OF THE 'FAIL SAFE' DESIGN, UNLOCKING WHEN THE FIRE ALARM IS ACTIVATED OR ELECTRICAL POWER IS INTERRUPTED. 7. ALL STAINLESS STEEL KICKPLATES SHALL BE 2" LESS THAN DOOR WIDTH x 12" HIGH (TYPICAL - U.O.N.) AND SHALL BE MOUNTED 1" FROM THE BOTTOM OF THE DOOR; SEE SPECIFICATION. 8. ALL HOLLOW METAL FRAMES SHALL BE SHOP WELDED UNLESS NOTED OTHERWISE. 9. SPECIES OF ALL DOORS SHALL MATCH EXISTING. 10. ALL METAL DOORS SHALL BE PAINTED - SEE ROOM FINISH SCHEDULE. DOOR NOTES ABBREVIATIONS AA ANODIZED ALUMINUM AL ALUMINUM DR DOOR EI VINYL CLAD DOOR HM HOLLOW METAL IHM INSULATED HOLLOW METAL K(12)KICKPLATE (HEIGHT") MTL.METAL MATL MATERIAL MIN MINERAL CORE PTD.PAINTED SCW SOLID CORE WOOD S.S.STAINLESS STEEL STL.STEEL T TEMPERED TI TEMPERED INSULATED U.N.O.UNLESS NOTED OTHERWISE V.I.F.VERIFY IN FIELD WD.WOOD 14" WG 14" WIREGLASS 1 4" T 1 4" TEMPERED 1" IG 1" INSULATED GLASS 01 A 3'-0"x 7'-0"x 1-3/4"SCW HM1--19/A201 19/A201 - 03 A 3'-0"x 7'-0"x 1-3/4"SCW 1-- HARDWARE SCHEDULE 1.112 - PAIR BUTT HINGES, BALL BEARING 1 - OFFICE LOCKSET WITH LEVER HANDLES 1 - DOOR STOP, WALL OR FLOOR MOUNT 1 - SET DOOR MUTES -1 -HM -1 04 B 3'-0"x 7'-0"x 1-3/4"SCW 1T--HM -1 05 A 3'-0"x 7'-0"x 1-3/4"SCW 1---HM -1 06 A 3'-0"x 7'-0"x 1-3/4"SCW 1-C-45 -HM C-45 1 1 FIXED H. M. W1 W2 3'-0"W x 4'-4"H 1/4" TEMPERED GLASS 1/4" TEMPERED GLASS W1 W2 WINDOW SCHEDULE R.O. SIZE ELEV.MARKREMARKS DETAIL SILLJAMBHEADTYPE 18/A201FIXED H. M. 1'-4"W x 4'-4"H 18/A201 18/A201 18/A201 18/A201 18/A201 WALLCOVERINGPAINTWALLCOVERINGPAINTPAINTSTAIN & VARNISHCARPETRESILIENT FLOORINGACCENTVINYL BASEPAINTSTAIN & VARNISHROOM FINISH SCHEDULE ROOM #ROOM NAME FLOOR BASE WALLS DOOR TRIM REMARKS WESTSOUTH WALLCOVERINGPAINTEAST WALLCOVERINGNORTH C1 PAINTALL FINSHES SHALL MATCH EXISTING GENERAL FINISH NOTES B A TRANSITION STRIPS SHALL BE JOHNSONITE COLOR TO BE DETERMINED. TRANSITION STRIPS SHALL BE INSTALLED DIRECTLY UNDER CLOSED DOOR, WHERE DOOR OCCURS. FINISH SCHEDULE NOTES 1 DOORS SHALL MATCH BUILDING STANDARD. FINISH SHALL BE 2 COATS OF STAIN TO MATCH EXISTING. B1 P1 S P2 -101 OPEN SPACE 103 OFFICE 104 OFFICE 105 OFFICE CONFERENCE ROOM 102 - - - - C1 C1 C1 B1 B1 B1 B1 S S S S P2 P2 P2 P2 P1 P1 P1 P1 P3 P4 P4 P4 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1C1 19/A201 19/A201 19/A201 19/A201 19/A201 19/A201 19/A201 19/A201 19/A201 19/A201 HOLLOW METAL FRAME - PAINT; SEE SPEC. (TYP.) CAULK CONT. (BOTH SIDES) 2x WOOD BLOCKING (FIRE -RETARDANT) SEE FLOOR PLAN FOR WALL TYPE 12" TYP.2"12"WALL ANCHORS & BASE CLIPS DOOR - SEE DOOR SCHEDULE DOOR HEAD / JAMB DETAIL SCALE: 3" = 1'-0" 19 A201 WINDOW HEAD / JAMB DETAIL SCALE: 3" = 1'-0" 18 A201 2"12" TYP. HOLLOW METAL FRAME - SEE SPEC. PAINT (TYP.) 2x WOOD BLOCKING (FIRE TREATED) SEE FLOOR PLAN FOR WALL TYPE CAULK CONT. (BOTH SIDES) 1/4" SAFETY GLASS RUBBER GASKET (TYP.) GLASS STOP 10/29/2018 11:41 AMINTERIOR ELEVATIONS, WALL TYPES, DOOR, WINDOW AND ROOM FINISH SCHEDULE A201 GS SEAL: MARK DATE ISSUE -10/29/2018 PERMIT SET PROJECT NO: PROJECT ARCHITECT: PROJECT MANAGER: DRAWN BY: DATE: COPYRIGHT: 18-073 REK REK 10/29/2018 SHEET TITLE: CONSULTANT: 64 GOTHIC STREET, SUITE 1 NORTHAMPTON, MA 01060 T 413.585.1512 F 413.586.7945 www.haiarchitecture.com H AI Architecture, Inc. 1st Floor Tenant Space Unit 1NW/1NE Cooledge Center LLC 47 Pleasant Street Northampton, MA 01060 Renovation for: PROJECT: