Loading...
38D-038 43 Harlow N'hamp Calc SheetKeyBeam® 4.600dkmBeamEngine 4.600y Materials Database 1415 Goodnow Harlow 46 8-15-13 10:10am 1 of 1 All product names are trademarks of their respective owners Copyright (C)1987-2012 by Keymark Enterprises, LLC. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Member Data Description:Member Type: Beam Application: FloorTop Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 20.7 PLF Filename: KYB2 Left End: 2.00/12 slope with 10.0000" heel height Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PSF) Top 0' 0.00" 18' 0.00" 12' 0.00" 40 10 SnowAdditional Uniform (PSF) Top 0' 0.00" 18' 0.00" 4' 0.00" 40 10 Live Additional Uniform (PSF) Top 0' 0.00" 18' 0.00" 6' 0.00" 30 10 Live 1 2 18 2 0 18 2 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) 5.500" 3.336" 7443# -- 2 18' 2.000" Wall SPF Plate (425psi) 5.500" 3.336" 7443# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 2957# 4175# 2094# 2 2957# 4175# 2094# Design spans17' 4.750" Product: 1-3/4x14 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Connect members with 3 rows of 16d common nails at 12.0" oc NOTE: Nails must be applied from both sides Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 32368.'# 52088.'# 62% 9.08' Total Load D+0.75(L+S)Shear 6444.# 16060.# 40% 16.91' Total Load D+0.75(L+S) Lt. Bevel/Notch 7380.# 12523.# 58% 0' Total Load D+0.75(L+S) Max. Reaction 7443.# 12272.# 60% 0' Total Load D+0.75(L+S)TL Deflection 0.7343" 0.8698" L/284 9.08' Total Load D+0.75(L+S) LL Deflection 0.5278" 0.5799" L/395 9.08' Total Load 0.75(L+S) Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 %