Loading...
11A-093 1st floor header calcsCS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 JazabEd40ChestnutAveLeeds11251 12- 5-14 1:09pm 1 of 3 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB1 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 8.4 PLF Filename: Q:\JazabEd40 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 6' 9.00" 513 251 Snow 1 2 6 9 0 6 9 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 2566# -- 2 6' 9.000" Wall N/A N/A 1.500" 2566# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Snow Dead 1 1706# 861# 2 1706# 861# Design spans 6' 7.750" Product: Spruce-Pine-Fir #2 2 x 10 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 4264.'# 6807.'# 62% 3.37' Total Load D+S Shear 1971.# 4308.# 45% 0.06' Total Load D+S LL Deflection 0.0542" 0.2215" L/999+ 3.37' Total Load S TL Deflection 0.0816" 0.3323" L/977 3.37' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 15 % This member has been designed in accordance with NDS 2005 CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 JazabEd40ChestnutAveLeeds11251 12- 5-14 1:09pm 2 of 3 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB2 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 8.4 PLF Filename: Q:\JazabEd40 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 0' 6.50" 392 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 0' 6.50" 271 339 Live Replacement Uniform (PLF) Top 0' 6.50" 6' 3.00" 392 0 Snow Replacement Uniform (PLF) Top 0' 6.50" 6' 3.00" 271 339 Live 1 2 6 3 0 6 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 2595# -- 2 6' 3.000" Wall N/A N/A 1.500" 2595# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 834# 1204# 1066# 2 834# 1204# 1066# Design spans 6' 1.750" Product: Spruce-Pine-Fir #2 2 x 10 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 3986.'# 6807.'# 58% 3.12' Total Load D+0.75(L+S) Shear 1944.# 4308.# 45% 0.06' Total Load D+0.75(L+S) LL Deflection 0.0384" 0.2049" L/999+ 3.12' Total Load 0.75(L+S) TL Deflection 0.0652" 0.3073" L/999+ 3.12' Total Load D+0.75(L+S) Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 15 % This member has been designed in accordance with NDS 2005 CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 JazabEd40ChestnutAveLeeds11251 12- 5-14 1:09pm 3 of 3 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB3 Member Type: Beam Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.7 PLF Filename: Q:\JazabEd40 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 16' 3.00" 0 53 Live Replacement Uniform (PLF) Top 0' 0.00" 16' 3.00" 149 0 Snow 1 2 16 3 0 16 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 1720# -- 2 16' 3.000" Wall N/A N/A 1.500" 1720# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 3# 1200# 521# 2 3# 1200# 521# Design spans 16' 1.750" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 6944.'# 24466.'# 28% 8.12' Total Load D+S Shear 1509.# 9081.# 16% 15.39' Total Load D+S TL Deflection 0.3336" 0.8073" L/580 8.12' Total Load D+S LL Deflection 0.2326" 0.5382" L/832 8.12' Total Load S Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives