Loading...
11A-093 1st floor girder Calcs(1)CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 JazabEd40ChestnutAveLeeds11251 12- 5-14 1:14pm 1 of 7 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG1 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 9.4 PLF Filename: Q:\JazabEd40 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 2' 5.50" 97 24 Live Replacement Uniform (PLF) Top 2' 5.50" 2' 9.56" 97 24 Live Replacement Uniform (PLF) Top 2' 9.56" 4' 0.00" 97 24 Live 1 2 4 0 0 4 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 218# -- 2 4' 0.000" Girder N/A N/A N/A 218# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 162# 56# 2 162# 56# Design spans 3' 3.875" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 181.'# 13958.'# 1% 2.05' Total Load D+L Shear 114.# 6317.# 1% 0.4' Total Load D+L TL Deflection 0.0010" 0.1661" L/999+ 2.05' Total Load D+L LL Deflection 0.0010" 0.1108" L/999+ 2.05' Total Load L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 JazabEd40ChestnutAveLeeds11251 12- 5-14 1:14pm 2 of 7 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG2 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 9.4 PLF Filename: Q:\JazabEd40 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 1' 8.00" 367 259 Snow Replacement Uniform (PLF) Top 0' 0.00" 5' 11.75" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 5' 11.75" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 5' 11.75" 33 65 Live Point (LBS) Top 0' 4.63" 0 93 Live Point (LBS) Top 0' 4.63" 125 31 Live Point (LBS) Top 0' 4.63" 461 115 Live Point (LBS) Top 1' 5.75" 3733 1959 Snow Point (LBS) Top 5' 7.38" 1084 189 Live 1 2 5 11 12 5 11 12 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 2.070" 5673# -- 2 5' 11.750" Wall N/A N/A 1.500" 2478# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 810# 3365# 2308# 2 1308# 838# 869# Design spans 5' 2.750" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 5517.'# 16051.'# 34% 1.48' Total Load D+S Shear 4869.# 7265.# 67% 0.4' Total Load D+S TL Deflection 0.0411" 0.2615" L/999+ 2.74' Total Load D+S LL Deflection 0.0249" 0.1743" L/999+ 2.74' Total Load S Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 JazabEd40ChestnutAveLeeds11251 12- 5-14 1:14pm 3 of 7 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG3 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 14.0 PLF Filename: Q:\JazabEd40 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 11' 11.00" 36 9 Live Replacement Uniform (PLF) Top 0' 0.00" 12' 11.00" 0 57 Live Replacement Uniform (PLF) Top 0' 0.00" 16' 5.50" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 16' 5.50" 27 7 Live Point (LBS) Top 0' 4.63" 0 162 Live Point (LBS) Top 0' 4.63" 589 0 Snow Point (LBS) Top 0' 4.63" 438 214 Snow Point (LBS) Top 0' 4.63" 273 447 Live Point (LBS) Top 0' 4.63" 1111 731 Snow Point (LBS) Top 11' 9.25" 189 58 Live 1 2 16 5 8 16 5 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 4635# -- 2 16' 5.500" Wall N/A N/A 1.500" 1285# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1005# 2139# 2277# 2 707# 0# 578# Design spans 15' 8.500" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 5813.'# 21774.'# 26% 8.24' Total Load D+L Shear 1311.# 9476.# 13% 0.4' Total Load D+L TL Deflection 0.3436" 0.7854" L/548 8.24' Total Load D+L LL Deflection 0.1783" 0.5236" L/999+ 8.24' Total Load L Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 JazabEd40ChestnutAveLeeds11251 12- 5-14 1:14pm 4 of 7 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG4 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 2.5 PLF Filename: Q:\JazabEd40 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 1' 6.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 1' 6.00" 27 7 Live Replacement Uniform (PLF) Top 1' 6.00" 17' 11.50" 27 7 Live Replacement Uniform (PLF) Top 1' 6.00" 17' 11.50" 27 7 Live Point (LBS) Top 0' 2.63" 0 121 Live Point (LBS) Top 0' 2.63" 19 126 Live Point (LBS) Top 0' 2.75" 33 187 Live 1 2 1 6 0 16 5 8 17 11 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 1' 6.000" Wall N/A N/A 3.500" 1190# -- 2 17' 11.500" Wall N/A N/A 1.500" 521# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 569# 621# 2 429# 92# Design spans 1' 6.000" (left cant) 16' 1.125" Product: 9-1/2" AJS 20 1 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1960.'# 3395.'# 57% 10.35' Even Spans D+L Negative Moment 698.'# 3395.'# 20% 1.5' Total Load D+L Shear 600.# 1160.# 51% 1.5' Total Load D+L Cant. Shear, Lt 589.# 1160.# 50% 1.49' Total Load D+L End Reaction 521.# 1175.# 44% 17.96' Even Spans D+L Int. Reaction 1190.# 2350.# 50% 1.5' Total Load D+L TL Deflection 0.4161" 0.8047" L/464 9.55' Even Spans D+L LL Deflection 0.3789" 0.5365" L/509 9.55' Even Spans L TL Defl., Lt. -0.0970" 0.2000" 2L/370 0' Even Spans D+L LL Defl., Lt. -0.1035" 0.2000" 2L/347 0' Even Spans L Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Left cantilever allowable shear is for joist only CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 JazabEd40ChestnutAveLeeds11251 12- 5-14 1:14pm 5 of 7 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG5 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 2.5 PLF Filename: Q:\JazabEd40 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 16' 5.50" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 16' 5.50" 27 7 Live Replacement Uniform (PLF) Top 16' 5.50" 17' 11.50" 27 7 Live Replacement Uniform (PLF) Top 16' 5.50" 17' 11.50" 27 7 Live Point (LBS) Top 0' 4.38" 251 65 Live Point (LBS) Top 17' 8.75" 33 187 Live Point (LBS) Top 17' 8.88" 0 121 Live Point (LBS) Top 17' 8.88" 19 126 Live 1 2 16 5 8 1 6 0 17 11 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 837# -- 2 16' 5.500" Wall N/A N/A 3.500" 1190# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 680# 157# 2 569# 621# Design spans 16' 1.125" 1' 6.000" (right cant) Product: 9-1/2" AJS 20 1 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1960.'# 3395.'# 57% 7.61' Odd Spans D+L Negative Moment 698.'# 3395.'# 20% 16.46' Total Load D+L Shear 599.# 1160.# 51% 16.45' Total Load D+L Cant. Shear, Rt 590.# 1160.# 50% 16.46' Total Load D+L End Reaction 521.# 1175.# 44% 0' Odd Spans D+L Int. Reaction 1190.# 2350.# 50% 16.46' Total Load D+L TL Deflection 0.4161" 0.8047" L/464 8.41' Odd Spans D+L LL Deflection 0.3789" 0.5365" L/509 8.41' Odd Spans L TL Defl., Rt. -0.0970" 0.2000" 2L/370 17.96' Odd Spans D+L LL Defl., Rt. -0.1035" 0.2000" 2L/347 17.96' Odd Spans L Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Right cantilever allowable shear is for joist only Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 JazabEd40ChestnutAveLeeds11251 12- 5-14 1:14pm 6 of 7 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG6 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 9.4 PLF Filename: Q:\JazabEd40 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 5' 11.75" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 11' 3.75" 27 7 Live Replacement Uniform (PLF) Top 5' 11.75" 9' 5.25" 6 1 Live Replacement Uniform (PLF) Top 9' 5.25" 14' 3.75" 27 7 Live Replacement Uniform (PLF) Top 11' 3.75" 14' 3.75" 27 7 Live Point (LBS) Top 0' 4.38" 1381 577 Live Point (LBS) Top 9' 3.50" 181 71 Live Point (LBS) Top 13' 11.13" 0 3 Live Point (LBS) Top 13' 11.13" 0 20 Live Point (LBS) Top 13' 11.13" 43 0 Snow Point (LBS) Top 13' 11.13" 76 22 Snow Point (LBS) Top 13' 11.13" 0 162 Live 1 2 14 3 12 14 3 12 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 2519# -- 2 14' 3.750" Wall N/A N/A 1.500" 839# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1772# 0# 747# 2 442# 119# 398# Design spans 13' 6.750" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2127.'# 13958.'# 15% 8.5' Total Load D+L Shear 573.# 6317.# 9% 13.25' Total Load D+L TL Deflection 0.1394" 0.6781" L/999+ 7.15' Total Load D+L LL Deflection 0.0969" 0.4521" L/999+ 7.15' Total Load L Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table