Loading...
24B-083 2017.10.16_KLW_780 CMR NARRATIVE780 CMR NARRATIVE In Compliance with Chapter 34 Hampshire Dermatology & Skin Health Center 39 Carlon Drive Northampton, MA 01060 Owner Messer Investments, Inc. 306 King Street Northampton, MA 01060 (413) 585-8500 Architect Nelligan White Architects PLLC 20 West 20th Street New York, NY 10011 (212) 675-0500 October 16, 2017 BACKGROUND INFORMATION: 39 Carlon Drive in Northampton is an existing single story masonry and steel building approximately 16’ high. The building contains business offices and will continue that use. The proposed project comprises a new renovation of the existing tenant space to the southwestern corner of the building with the existing entry on Carlon Drive. The building contains no basement and is at grade. The building is serviced and surrounded by its parking lot for 30 cars to the north and east with appropriate existing signage and access points at grade. There is an adjoining parking (not yet paved) lot to the west. The proposed medical offices are expected to draw on the Northampton local area for the bulk of its patients. PROPOSED MEDICAL OFFICE RENOVATION: The medical office renovation for Dr. Katherine L. White, MD, PC is for her medical practice that specializes in dermatology. Routine examinations of patients and dermatological procedures will be performed, which will occur during normal working hours. In total, there will be three existing exam rooms plus three newly renovated exam rooms, and one existing procedure room and one newly renovated procedure room. The three new exam rooms and one new procedure room will replace existing offices on the first floor of this building. The new offices will maintain the existing tenancy area of approximately 3,370 square feet and will comply with all code requirements including fire alarm, egress, ADA compliance, etc, and will maintain the same entry and exit locations. EXECUTIVE SUMMARY: The new medical office exam & procedure rooms that constitutes this renovation, will replace the current offices in this tenancy of the building. Zoning approval for use of the subject office space for medical office was obtained by the Owner on 12-17-2008, Hearing No., PLN-2009- 0012. Approximately 200 square feet of existing medical offices will be demolished, and the new medical offices constructed as code compliant. In addition to the existing two means of egress, one additional means of egress will be provided, therefore upgrading life-safety. No exterior path of travel will be altered; no existing code compliant components that may remain will be degraded. The new medical offices will maintain or upgrade all existing fire and smoke separations, fire suppression system, exiting lights, exiting paths, contain only metal wall stud framing and Class II or B/C interior finish material, and install fire safing at all penetrations as part of this project. No new services will be required for this project, and there will be no decrease in the public safety, health, and general welfare as a result of this tenancy renovation. DETAILED CODE SUMMARY The following is a detailed summary of Code related items as regulated by 780 CMR including Chapter 34 for alterations to an existing building: Compliance: The renovation shall be in accordance with the prescriptive compliance method for alterations as per 2009 International Existing Building Code, Chapter Three, for Alterations. Alterations shall be such that the existing building or structure is no less conforming to the provision of the International Building Code that the existing building or structure was prior to the alteration. Zoning: The existing zoning classification for the site is B (Business) and this project will not request any change. Occupant Load: The occupant load allowed for these medical offices is 34 persons based on the 3,370 s.f. being partially modified as part of this project. The actual occupant load will more likely be 15 –34 maximum. Construction Classification: The existing construction is 2B and this project intends on matching or improving this classification. Section Item Required Proposed 304.1 Use Group B Existing to remain. 503.1 Table 503 Height and Area Limitations for Construction Classification 2B 4 stories and 23,000 s.f. max Renovation is 3,370 s.f., therefore less than 23,000 s.f. 602.1 Table 602 Protection of Exterior Walls ≥10ft 0 hour Existing to remain. 602.2 Table 601 Protection of Structural Members 0 hour Existing to remain. 602.2 Table 601 Roof/Clg, Flr/Clg Assemblies 0 hour Existing to remain. 704.8 Exterior Wall Allowable Area of Openings -Unprotected >5ft - 10ft = 10% >10ft – 15ft = 15% 6% (side) 1.3% no change (front) 803.5 Table 803.5 Non Sprink. Interior finish requirements Corridors to exits Rooms or spaces Class B Class C Class B Class C 804.5.1 Interior Floor Finish - Use Group B Class II or better Class II or better 903.2.2 Fire Suppression System Requirement Not required if area less than 12,000sf None existing. Existing Bldg. area approx 9,000sf 906.2 Portable Fire Extinguisher Required Will comply 1003.2 Use Group B Ceiling Heights in exit access and occupiable rooms >7’-0” Ceiling height 9’-0” provided 1004.1 Maximum Floor Area per Occupant in Use Group B 100 g.s.f. = 34 15 – 34 1005.1 Exit Capacity minimum width in Use Group B without sprinklers 0.2 required 36” allowed under 1011.3 6.8” and 150” actual 1016.1 Path of Egress Travel Distance 200 ft 60 ft max. 1014.0 Table 1014.1 Minimum Number of Exits Allowed Occupancy B, Max load 50 1 3 Max load 24 1203.1 Ventilation Requirement Mechanical or natural Mechanical CHAPTER 34: Alteration, Addition, and Change of Use of Existing Buildings 3400.3 Applicability Will continue Use Group B 3400.4 Non-conforming egress Existing Existing is conforming therefore not applicable 3400.5 Hazardous Means of Egress Existing Existing does not appear to be hazardous. New work and modifications will comply. 3400.6 Unsafe Lighting/Ventilation Existing Existing does not appear to be unsafe or inadequate. New work and modifications will comply. 3402.1.1 Existing Building Investigation and Evaluation for Building Permit Application Will comply 3402.1.2 Investigation and Evaluation Submittal This report will be submitted for consideration 3404.3 New Building Systems will conform to 780 CMR for new construction New work and modifications will comply with 780 CMR 3404.4 Alterations and Repairs New work and modifications will comply. 3404.5 Means of Egress in compliance with 1014.0 requires 1 3 exits will be maintained 3404.6 Exit Capacity to comply with 1005.1 New work and modifications will comply. 3404.7 Exit Sign and Lighting to comply with 1023 New work and modifications will comply. 3404.9 Height and Area Limitations to comply with 504, 505, 506 Existing complies and there is no change in height or area. 3404.12 Fire Protection Systems to comply with 9 No change in Use Group. New work and modifications will comply. 3404.18 Accessibility for Persons with Disability The existing complies and all new work and modifications will comply. 3404.19 Energy Conservation Measures New work will maintain or increase energy conservation End of Review