18WD-3-23 - FULL DIMENSION 2X4 POST 4 - 2X4 POST 2 - 12" LVL X 12' ± BEAM TO DISTRIBUTE LOAD ALONG WALL 5775 lbs6132 lbsMATCH EXISTING SLOPE2 - 1/2" X 11 3/4" STEEL GUSSET PLATES SANDWITCHED BETWEEN 12" LVL, INSTALL 1/2" PLYWOOD THE REMAINING LENGTH OF THE BEAM. 3 - 12" LVL BENT BEAM 1/2" STEEL GUSSET PLATE, NEED 2 HOLES FOR 1/2" BOLTS, SAME LAYOUT 2"3 7/8"3 7/8"2"3 1/2"4 3/4"3 1/2"11 3/4"4'-0"4'-0"1 1/4"6"6"6"6"6"6" FINISH DECK BOARDS ANGLED 2X_ SLEEPER EPDM ROOFING 3/4" T&G ROOF SHEATHING ANGLED 2X_ SLEEPER 3/4" T&G ROOF SHEATHING CEILING JOIST R-49 INSULATION, MIN GWB CEILING DTT2Z SIMPSON POST CONNECTOR, TYP. EXISTING AND NEW SHEATHING NAILED TO BEAMS NEW LVL, SEE STRU. EXISTING T&G FINISH FLOOR EXISTING BOARD SHEATHING EXISTING 2"X7.5" JOISTS EXISTING PLASTER PAN FLASHING OVER EPDM ROOF FLAP POST IS ATTACHED TO BLOCKING IN WALL 4 - DTT2Z SIMPSON, 1/2" THREADED ROD THROUGH LVL TO DTT2Z AT 2X8 BLOCKING IN EXISTING CEILING. JOIST HANGERS EACH JOIST, TYP. Maple Street Architects Northampton, MA (413) 570-3213 Date: 01 May 2018 A3.2DETAILS N Scale: 1" = 1' - 0" 36 Ward Ave Northampton, MA DETAILS AT THIRD FLOOR DECK Scale: 1/4" = 1' - 0" BENT BEAM AT THIRD FLOOR Scale: 1" = 1' - 0" STEEL GUSSET THIRD FLOOR BENT BEAM