24A-143 CS porch Beam CalcsCS Structure™ 2016.4 [Build 5] kmBeamEngine 4.13.19.1 Materials Database 1548 DadmunTomOreilly - Level 8 5-23-16 11:50am 1 of 3 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG3 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 7.3 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 7' 6.50" 1 62 Live Replacement Uniform (PLF) Top 0' 0.00" 7' 6.50" 204 0 Snow 1 2 0 5 12 7 0 12 7 6 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 5.750" Wall SPF Plate (425psi) N/A 1.500" 1010# -- 2 7' 6.500" Girder SPF Plate (425psi) N/A N/A 924# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 2# 754# 256# 2 2# 690# 234# Design spans 0' 3.625" (left cant) 6' 9.250" Product: 1-3/4x7-1/4 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1561.'# 9634.'# 16% 3.86' Total Load D+S Negative Moment 12.'# 9634.'# 0% 0.48' Total Load D+S Shear 762.# 5544.# 13% 0.49' Total Load D+S TL Deflection 0.0579" 0.3385" L/999+ 3.86' Total Load D+S LL Deflection 0.0432" 0.2257" L/999+ 3.86' Total Load S TL Defl., Lt. -0.0082" 0.2000" 2L/880 0' Total Load D+S LL Defl., Lt. -0.0061" 0.2000" 2L/999+ 0' Total Load S Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2016.4 [Build 5] kmBeamEngine 4.13.19.1 Materials Database 1548 DadmunTomOreilly - Level 8 5-23-16 11:50am 2 of 3 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG5 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 7.3 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 0' 5.50" 76 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 0' 5.50" 33 112 Live Replacement Uniform (PLF) Top 0' 0.00" 9' 2.00" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 9' 2.00" 6 1 Live Replacement Uniform (PLF) Top 0' 0.00" 9' 2.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 9' 2.00" 40 13 Live Replacement Uniform (PLF) Top 0' 5.50" 1' 2.00" 18 5 Snow Replacement Uniform (PLF) Top 0' 5.50" 9' 2.00" 58 0 Snow Replacement Uniform (PLF) Top 0' 5.50" 9' 2.00" 33 107 Live Replacement Uniform (PLF) Top 1' 2.00" 9' 2.00" 108 53 Snow Point (LBS) Top 0' 3.13" 244 202 Live Point (LBS) Top 1' 0.25" 0 53 Live Point (LBS) Top 1' 0.25" 174 0 Snow Point (LBS) Top 1' 0.25" 2 257 Live Point (LBS) Top 1' 0.25" 691 0 Snow 1 2 0 5 8 8 8 8 9 2 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 5.500" Wall SPF Plate (425psi) N/A 1.693" 2887# -- 2 9' 2.000" Wall SPF Plate (425psi) N/A 1.500" 1689# -245# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 705# 1450# 1270# 2 437# 745# 802# Design spans 0' 2.375" (left cant) 8' 3.875" Product: 1-3/4x7-1/4 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 3641.'# 9634.'# 37% 4.62' Even Spans D+0.75(L+S) Negative Moment 512.'# 8377.'# 6% 4.62' Even Spans D+L Shear 2270.# 5544.# 40% 0.47' Total Load D+S TL Deflection 0.2070" 0.4161" L/482 4.62' Even Spans D+0.75(L+S) LL Deflection 0.1102" 0.2774" L/905 4.62' Even Spans 0.75(L+S) TL Defl., Lt. -0.0164" 0.2000" 2L/289 0' Even Spans D+0.75(L+S) LL Defl., Lt. -0.0088" 0.2000" 2L/537 0' Even Spans 0.75(L+S) CS Structure™ 2016.4 [Build 5] kmBeamEngine 4.13.19.1 Materials Database 1548 DadmunTomOreilly - Level 8 5-23-16 11:50am 3 of 3 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table