32A-162 33 HAWLEY IBC CODE REVIEWCode Review Thomas Douglas
Architects, Inc.
The Northampton Community Arts Trust, 33 Hawley St, Northampton, MA 196 Pleasant St.
Northampton,MA
413-585-0641
1 of 5
CODE
REVIEW
September
22,
2015
The
Arts
Trust
Building
33
Hawley
Street,
Northampton,
MA
01060
Applicable
Building
Code:
MA
780
CMR
Eighth
Addition
IBC,
IEBC
International
EXISTING
Building
Code,
2009
ZONING
DISTRICT:
PROPOSED
RENOVATIONS:
PROJECT
DESCRIPTION:
• Renovations
of
the
building
will
include
1. Remove
all
interior
partitions
shown
on
demo
plan
2. Remove
exterior
wall
and
roof
cladding
3. Reinstall
exterior
roof
and
wall
cladding
to
high
performance
standards
4. Renovate
the
interior
of
the
building
to
a
performing
arts
center
5. Construct
a
new
exterior
entry
vestibule.
Use
Groups,
Section
310
• Change
the
entire
building
from
B,
Business
use
group
to
A1,
Assembly,
theater
use
group.
Construction
Type
• 5B
Sprinkler
System
• The
entire
building
will
be
fully
sprinkled.
There
is
an
existing
sprinkler
system
in
the
building.
It
will
be
reconfigured
for
the
new
use.
Fire
and
Smoke
Alarm
&
Detection
• A
manual
fire
alarm
system
and
an
automatic
smoke
detection
system
will
be
installed
throughout
the
building.
•
Seismic
Zone
• See
structural
code
review
According
to
the
IEBC
this
renovation
is
being
reviewed
as:
Prescriptive
Compliance
Method,
Chapter
3
Code Review Thomas Douglas
Architects, Inc.
The Northampton Community Arts Trust, 33 Hawley St, Northampton, MA 196 Pleasant St.
Northampton,MA
413-585-0641
2 of 5
303
Alterations:
Alterations
to
any
building
or
structure
shall
comply
with
the
requirements
of
the
IBC
code
for
new
construction.
303.3
Existing
Structural
elements:
see
attached
structural
review.
307
Change
of
Occupancy:
This
section
requires
that
the
provisions
of
the
IBC
code
for
new
construction
be
applied
to
an
existing
structure
having
a
new
occupancy.
Fire
Resistive
Required
Types
of
Construction,
Table
601
&
602
Building
Element Type
5B
Primary
Structural
Frame
0
Bearing
walls,
Exterior 0
Bearing
walls,
Interior 0
Nonbearing
walls
and
partitions,
exterior
0
Nonbearing
walls
and
partitions,
interior
0
Floor
construction
and
secondary
members
0
Roof
construction
and
secondary
members
0
Maximum
Allowable
Height/Area
(section
503-‐506)
Table
503,
508.4.2:Allowable
building
area:
506.1
Building
area
modifications:
Building
areas
from
Table
503
shall
be
permitted
to
be
increased
due
to
frontage
and
sprinklers.
• Maximum
allowable
area
per
floor:
19,403
s.f.
•
• Proposed
maximum
floor
area
(1st
floor):
12,546
s.f.
505
Mezzanine:
There
is
a
mezzanine
above
the
1st
floor
and
it
is
open
to
the
lobby
below.
It
is
less
than
1/3
of
the
area
of
the
lobby
space
below.
The
mezzanine
occupancy
is
less
than
50
and
only
requires
one
means
of
egress.
(1015.1)
The
mezzanine
is
accessible
via
the
new
elevator.
The
travel
distance
from
the
most
remote
spot
on
the
mezzanine
to
the
bottom
of
the
stairs
at
the
lobby
level
is
72
feet.
The
maximum
allowable
travel
distance
is
75
feet.
(1028.8,
1014.3)
Ceiling
height
requirements
above
and
below
the
mezzanine
comply
with
the
code.
(7
feet)
The
stair
leading
from
the
mezzanine
to
the
lobby
is
not
considered
an
exit
stairway,
but
is
part
of
exit
access
and
is
not
required
to
be
a
vertical
exit
enclosure.
Code Review Thomas Douglas
Architects, Inc.
The Northampton Community Arts Trust, 33 Hawley St, Northampton, MA 196 Pleasant St.
Northampton,MA
413-585-0641
3 of 5
The
adjacent
mechanical
space
will
have
a
1-‐hour
fire
rated
wall
and
will
be
for
employee-‐only
access.
FIRE
SEPARATIONS:
707
712
508.4
707.3.8
Separated
Occupancies
Table
508.4
Required
Separation
of
Occupancies
Table
508.2.5
Incidental
Accessory
Occupancies
1022
Exit
Enclosures
• There
is
1
proposed
occupancy
in
this
building.
It
is
A1
• There
is
1
proposed
tenant
in
this
building.
• There
are
no
required
separations
for
any
spaces
in
this
building
other
than
mechanical
rooms,
elevator
machine
rooms,
and
exit
stairs.
• Interior
Stairway
enclosures
(1019):
There
are
no
enclosed
interior
stairs.
Each
floor
has
multiple
exits
leading
directly
to
the
exterior.
The
interior
stairs
are
supplemental,
only
connect
2
floors,
and
can
be
open
to
the
floor
below.
• Elevator
Machine
rooms:
1
hour
• Elevator
Hoistway,
shaft
enclosure,
fire
barrier:
1
hour
when
connecting
4
stories
or
less
(section
708.4
Fire
Resistance
rating)
• Mechanical
Room:
Furnace
room:
Where
any
piece
of
equipment
is
over
400,000
BTU
per
hour
input,
a
1
hour
fire
separation
or
sprinklers
are
required.
The
mechanical
rooms
on
the
mezzanine
and
basement
levels
will
have
1-‐hour
fire
barrier
walls
separating
them
from
the
adjacent
spaces.
•
410
Stages
and
Platforms
• There
are
no
raised/fixed
stages
or
platforms
proposed
in
this
building.
• There
are
no
proscenium
walls
or
fly
galleries
in
this
building.
• Dressing
rooms
do
not
need
to
be
separated
from
the
stage
because
there
are
no
fixed
stages.
• There
are
no
property
rooms,
scene
docks,
or
workshops
appurtenant
to
the
stage.
1018
Corridors
• No
fire
rated
corridors
are
proposed
in
this
building.
Means
of
Egress
1018.4
Dead
ends
With
an
automatic
sprinkler
system,
dead
end
corridors
are
limited
to
50
feet.
This
project
does
not
have
dead
end
corridors
exceeding
50
feet.
1012.2
Handrail
height
1012.9
Intermediate
handrails
Code Review Thomas Douglas
Architects, Inc.
The Northampton Community Arts Trust, 33 Hawley St, Northampton, MA 196 Pleasant St.
Northampton,MA
413-585-0641
4 of 5
The
new
entry
stair
at
the
front
sidewalk
entry
is
a
“monumental
stair.
It
exceeds
60
inches
in
width.
Intermediate
handrails
shall
be
constructed.
1010.9
Edge
protection
for
ramps
is
required
805.2
Means
of
Egress
Lighting
Means
of
egress
lighting
will
be
installed
throughout
the
entire
building
805.3
Exit
signs
Means
of
egress
throughout
the
entire
building
will
have
new
exit
signs
installed.
705.4.2
Door
swing.
All
means
of
egress
doors
will
swing
in
the
direction
of
travel.
705.4.4
Panic
hardware:
Panic
hardware
is
required
for
this
project.
Exits
Required
Exits
required
Exits
provided
Exit
Width
stair
.3”
per
occupant
Exit
Width
other
components
.2”
per
occupant
Basement
Floor 1 1 135”
min
90”
min
First
Floor 1 1 114”
min
76”
min
Second
Floor 2 2 44”
min 44”
Section
1009.1
prescribes
that
the
width
of
an
interior
stairway
cannot
be
less
than
44
inches
Travel
Distance
(1016.1)
With
NO
sprinkler
System
With
sprinkler
System
Proposed
max
travel
distance
A
use
Bsmt
&
1st
floors
250’
74
feet
Chapter
9
Fire
Protection
Systems:
• An
automatic
sprinkler
system
will
be
provided
throughout
the
entire
building.
• Fire
alarm
and
smoke
alarm
systems.
See
narrative
from
Mechanical
Engineer,
Lindgren
and
Sharples.
Code Review Thomas Douglas
Architects, Inc.
The Northampton Community Arts Trust, 33 Hawley St, Northampton, MA 196 Pleasant St.
Northampton,MA
413-585-0641
5 of 5
711
Energy
Conservation
Required
values
according
to
the
MA
stretch
code
that
this
project
will
exceed:
MA:
climate
zone
5A
Roofs:
R-‐38
Walls
above
grade:
R-‐13+R-‐7.5
ci=
R20.5
Walls
below
grade:
R-‐7.5
Slab
on
grade
Floors,
unheated:
R-‐10
806
Accessibility
CMR
521
3.3.1
b.
If
the
work
costs
$100,000
or
more,
then
the
work
being
performed
is
required
to
comply
with
521
CMR.
In
addition,
an
accessible
public
entrance
and
an
accessible
toilet
room
shall
be
provided.
3.3.2
If
the
work
performed,
including
the
exempted
work,
amounts
to
30%
or
more
of
the
full
and
fair
cash
value
of
the
building,
the
entire
building
is
required
to
comply
with
521
CMR.
This
project’s
construction
costs
will
exceed
30%
of
the
assessed
value
of
the
entire
building.
The
building
will
be
designed
to
be
fully
accessible.
A
new
elevator
and
front
entry
ramp
will
be
constructed.
All
toilet
rooms
will
be
accessible.