Loading...
43-097 fwdpdfsforlamsonpermitapplication Lamson A-1.pdfLamson porch deck.vwx 7-5-17FOR REVIEW ml CONSTRUCT ASSOCIATES, INC. 36 SERVICE CENTER NORTHAMPTON, MA 01060 tel: 584-1224 fax: 584-7504 EXISTING AND PROPOSED PLANS A-1 1/4" = 1'-0" 1'-8 1/2" 4'-3" 2'-9" 4'-2 1/2" B E EXISTING PORCH AND DECK FLOOR PLAN 1/4" = 1'-0" 1 WOOD DECK Window Schedule Frame SizeRough OpeningsWindow Data Mark Unit Width Unit Height Sash Operation Jamb Depth R.O. Width R.O. Height Head Height Mfr Quantity Model No.Comments A3'9"5'8"DOUBLE HUNGVIF3'10"5'8 1/2"EXISTINGPARADIGM9DH4568(4) WITH TEMPERED GLASS B4'8 1/2"3'4 3/4"GLIDERVIF4'9 1/2"3'5 1/4"EXISTINGPARADIGM1G5640REPLACE EXISTING WINDOW C3'8 3/4"3'10 1/4"VENTING SKYLIGHTN/A3'8 1/4"3'9 3/4"MATCHVELUX1VS S06LOW SLOPE INSTALLATION D2'6"5'8"DOUBLE HUNGVIF2'7"5'8 1/2"PARADIGM2DH3068TEMPE RED GLASS E5'5"4'0"DOUBLE HUNGVIF5'6"4'0 1/2"EXISTINGPARADIGM1DH2848-2MULLED UNIT COVERED PORCH +6" +0" SKYLIGHT ABOVE SKYLIGHT ABOVE DN 1R DN KITCHEN DEN GARAGE PROPOSED PORCH AND DECK FLOOR PLAN WITH ELECTRICAL NOTES 1/4" = 1'-0" 2 IPÉ DECK A A A A A A A COVERED PORCH +6" +0" SKYLIGHT ABOVE SKYLIGHT ABOVE DN KITCHEN DEN GARAGE D D AA NEW SKYLIGHT ABOVE 26'-6" OIL FILLER AND BREATHER NEW, WIDER WINDOW REPLACE WINDOW WITH SIM. SIZED SLIDER WINDOW SEAT, WITH DRAWERS BELOW. DETAILS TBD. ALL NEW WINDOWS AT PORCH IN EXISTING OPENINGS ± 12'-3 1/2" , EXISTING 13'-7 1/2"17'-9 1/2" 12'-3 1/2" WALL HEIGHT: 10'-0" WALL HEIGHT: 7'- 9 1/2" TEMPERED GLASS AT THESE FOUR WINDOWS 3'-9" 4'-0" VERIFY VERIFY C A-3 1 EXTEND FLOOR FRAMING AND DECKING TO MATCH EXISTING PORCH FLOOR HEIGHT EXTEND EXISTING OIL FILLER AND BREATHER NEW POURED CONCRETE PIER WITH FLARED BOTTOM NEW STONE PATIO TO BE DETERMINED NEW STAIRS WITH IPÉ TREADS, TO GRADE DN 4'-11" SPLIT SYSTEM CONDENSER: POSITION TBD SPLIT SYSTEM CONDENSER: POSITION TBD EX'G FAN NEW FAN DN 1R FEED FOR CONDENSER FEED FOR CONDENSER ADDITIONAL PROJECT NOTES: HVAC - NEW SPLIT SYSTEM AC UNITS TO BE ADDED TO SECOND FLOOR BEDROOMS AND KITCHEN AT FIRST FLOOR. KITCHEN WINDOW TO BE REPLACED WITH SIMILAR SIZED SLIDER UNIT. NEW REPLACEMENT WINDOW AT DEN - SIZE TO BE DETERMINED. REPLACE EXISTING LATTICE BELOW PORCH WITH VINYL TYPE LATTICE . INCLUDE REMOVEABLE PANEL FOR ACCESS. NEW HARDSCAPE BEHIND GARAGE TO BE DETEMINED. ROOFING TO BE DETERMINED. NEW PORCH SIDING TO MATCH EXISTING HORIZ'L CLAPBOARDS. EXTEND WHITE ALUMINUM GUTTER TO FULL PORCH LENGTH. 1'-6" NEW IPÉ DECKING. VERIFY SUITABILITY OF EXISTING FRAMINGt t t t t = TEMPERED GLASS VERIFY 8'-8 1/2" LINE OF EX'G PORCH 1'-6 1/2"2'-0 1/4" 4'-4 1/2" 4'-4 1/2" B A B A 123 CC Drawn By DateIssue 123 RENOVATIONS FOR: LAMSON / JOHNSON RESIDENCE 31 WHITTIER ST. FLORENCE, MA 01062 7-28-17FOR REVIEW 8-7-17FOR REVIEW 8-14-17FOR REVIEW 9-11-17REVISED Lamson A-2.pdfLamson porch deck.vwx EXISTING PORCH AND GARAGE ROOF PLAN 1/4" = 1'-0" 1 DECK BELOW SKYLIGHT FIRST FLOOR ROOF BELOW PORCH ROOF BELOW EXISTING CHIMNEY SKYLIGHT SECOND FLOOR BEDROOM SECOND FLOOR BEDROOM SECOND FLOOR BATHROOM PROPOSED PORCH ROOF PLAN 1/4" = 1'-0" 2 DECK BELOW EXISTING SKYLIGHT FIRST FLOOR ROOF BELOW PORCH ROOF BELOW EXISTING CHIMNEY EXISTING SKYLIGHT BEDROOMBEDROOM BATHROOM NEW SKYLIGHT EXTEND NEW PORCH ROOF OVER EXISTING ROOF AS REQUIRED CONTINUE EXISTING SHED ROOF OVER EXTENDED PORCH WHITE ALUMINUM GUTTER AND DOWNSPOUT WHITE ALUMINUM GUTTER AND DOWNSPOUT A-3 1 EXISTING RIDGE EXISTING RIDGE ALTER EXISTING GUTTER TO SUIT 7-5-17FOR REVIEW ml CONSTRUCT ASSOCIATES, INC. 36 SERVICE CENTER NORTHAMPTON, MA 01060 tel: 584-1224 fax: 584-7504 EXISTING AND PROPOSED ROOF PLANS A-2 1/4" = 1'-0" B A B A 123 CC Drawn By DateIssue 123 8-1-17FOR REVIEW RENOVATIONS FOR: LAMSON / JOHNSON RESIDENCE 31 WHITTIER ST. FLORENCE, MA 01062 Lamson A-3.pdfLamson porch deck.vwx B A B A 123 CC Drawn By DateIssue 123 ml CONSTRUCT ASSOCIATES, INC. 36 SERVICE CENTER NORTHAMPTON, MA 01060 tel: 584-1224 fax: 584-7504 SECTION A-3 1/2" = 1'-0" 1 12 12 ± 2.5 4 7'-10" WALL HEIGHT SECTION AT NEW PORCH 1/2" = 1'-0" EXISTING HOUSE MATCH EXISTING PORCH ROOF PITCH EXTEND NEW ROOF ONTO EXISTING GARAGE ROOF AS REQUIRED. VERIFY SECOND FLOOR WINDOW CLEARANCE. NEW SKYLIGHT TO MATCH LOCATION AND DIMENSION OF EXISTING (2) SKYLIGHTS NEW FLOOR SYSTEM TO MATCH EXISTING PORCH EXISTING FLASHING AND COUNTERFLASHING AT EXISTING CHIMNEY BEYOND REMOVE EXISTING SOFFIT AT NEW PORCH EXISTING DOUBLE TOP PLATE NEW CRIPPLE WALL ABOVE EXISTING REAR WALL MEMBRANE ROOFING ON 5/8" PLYWOOD DECKING 1/2" GWB CEILING ON VAPOR BARRIER ON 2 X 8 RAFTERS, 16" O.C. LINE OF EXISTING GARAGE ROOF BEYOND NEW PORCH 7'-1" ROUGH HEAD 1'-4 1/2" 12" POURED CONCRETE FOOTING PIER WITH FLARED BOTTOM 1/2" X 12 ANCHOR BOLT SIMPSON POST CONNECTOR 2 X 10 FLOOR JOIST, 16" O.C. EXISTING FOUNDATION MATCH EXISTING ROOF TRIM ALUMINUM DRIP EDGE ALUMINUM GUTTER MATCH ANGLES AT EXISTING SKYLIGHT SHAFT EXISTING WALL LATTICE AND FRAME TO GRADE 6 X 6 PRESSURE-TREATED POST, TYPICAL (2) 2 X 10 BAND JOIST VERIFY PITCH VERIFY PITCH 'BEND' ROOF AT WALL TO ALLOW HIGH END TO FINISH AT EXISTING RIDGE , IF REQUIRED 7'-10" 7'-9 1/2" SPRAY FOAM INSULATION SPRAY FOAM INSULATION MATCH EXISTING 10'-0" MATCH EXISTING MATCH EXISTING WALL FRAMING: 2 X 4 16" O.C. JOIST HANGER, TYPICAL 2 X 10 PT LEGDER W/ (2) LEDGERLOK SCREWS AT 16" CENTERS 5'-8 1/2" R.O. (2) 2 x 8 HEADER, TYPICAL, WITH SINGLE TOP PLATE 1'-9"TO GLASS ROUGH 9" 4'-0" MIN. RENOVATIONS FOR: LAMSON / JOHNSON RESIDENCE 31 WHITTIER ST. FLORENCE, MA 01062 7-5-17FOR REVIEW 8-1-17FOR REVIEW 9-11-17REVISED Lamson A-4.pdfLamson porch deck.vwx 7-7-17FOR REVIEW ml CONSTRUCT ASSOCIATES, INC. 36 SERVICE CENTER NORTHAMPTON, MA 01060 tel: 584-1224 fax: 584-7504 EXISTING AND PROPOSED ELEVATIONS A-4 1/4" = 1'-0" 1EXISTING REAR ELEVATION 1/4" = 1'-0" 2PROPOSED REAR ELEVATION, PARTIAL 1/4" = 1'-0" EXISTING CHIMNEY EXISTING GARAGE ROOF EXISTING HOUSE EXISTING GARAGE EXISTING DOOR TO REMAIN NEW ROOF, EXTENDED NEW SKYLIGHT, VERIFY SIZE NEW PVC LATTICE TO GRADE NEW HORIZONTAL SIDING CONCRETE FOOTING PIER NEW DOUBLE-HUNG WINDOWS 1'-9" PORCH FINISH FLOOR 7'-10" EX'G WALL HT. 3NEW SIDE ELEVATION 1/4" = 1'-0" FINISH FLOOR HANDRAIL AT GARAGE WALL HANDRAIL AT NEW STAIR NEW STAIR TO GRADE NEW HVAC CONDENSER NEW HVAC CONDENSER: LOCATION TBD 3'-8" 5'-8" AAAAAA DD TO GLASS VERIFY ADD TRIM TO MAKE DOOR MATCH WINDOWS, AS REQUIRED RENOVATIONS FOR: LAMSON / JOHNSON RESIDENCE 31 WHITTIER ST. FLORENCE, MA 01062 7-31-17FOR REVIEW B A B A 123 CC Drawn By DateIssue 123 8-1-17FOR REVIEW 8-7-17FOR REVIEW 9-11-17REVISED