Loading...
233 Emerson Card-HERS233 EMERSON WAY GIS #: Map:Block: 36 -380 BP-2018-0930 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS "--'Pe=nn=it"---: ---=B-=ui=ld=in~g DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: New Single Family House BUILDING PERMIT Penn it # BP-2018-0930 Project# JS-2018-001699 Est. Cost: $460000.00 Fee: $1808.60 Const. Class: Use Group: Lot Size(sq. ft.): 12022.56 Applicant Address: 135 SOUTHAMPTON RD Compensation PERMISSION IS HEREBY GRANTED TO: Contractor: License: SOVEREIGN BUILDERS INC060176 Owner: BELDENGREEN CLAUDIA Ap:--lh:nt1~: SOVEREIGN BUILDERS I_NC AT: 233 EMERSON WAY Phone: Insurance: (413) 527-8001 WESTHAMPTONMA01027 ISSUED ON:4125/2018 0:00:00 TO PERFORM THE FOLLOWING WORK:NEW SINGLE FAMILY HOUSE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Underground: Rough:/~~~~ Final: ~ Gas: Inspector of Wiring Service: Rough: Final:/./ 1-/q ~~ Fire Department D.P.W. Meter: Ho:.1se# Drive\\-ay Final: Building Inspector Footings: Foundation: Rough Frame: a/ I.... Lt,b Fireplace/Chimney: Workers Rough: Final, 06}9 Smoke, A I I q ?ft_ ~ l 1fl I t Insulation, 0 I< 1 /1..s ( I ~ L to Fin:11: (),(, )-11-lt? fJ2 THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND RE U TIONS. Certificate of Occu FeeType: Building Si nature: Date Paid: Amount: 4/25/2018 0:00:00 $1808.68 212 Main Street, Phone (413) 5S7-1240, Fax: (413) 587-1272 Louis Hasbrouck-Building Commissioner 2015 IECC Building UA Compliance Property Todd G. Cellura 233 Emerson Way Northampton, MA 01062 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Weather:Chicopee, MA Builder Todd Cellura Custom Home Sovereign Builders Inc. 0073-0382-C 1 _Sovereign_Builders _lnc_233_Emerson_ Way _CODE_HE HERS Confirmed 2019-01-15 Rating No:0073_0382 Rater 10:8776762 Elements Insulation Levels Shell UA Check Ceilings: Above-Grade Walls: Windows and Doors: Floors Over Ambient: Basement Walls: Overall UA (Design must be equal or lower): Mandatory Requirements Shell UA Check Duct Insulation R-Value Check (per Section 403.3.1) Window U-Value and SHGC Check (per Section 402.5) Home Infiltration (Section 402.4.1.2) Duct Testing (Section 403.3.3) Mechanical Ventilation (Section 403.6) Mechanical Ventilation Fan Efficacy (Section 403.6.1) Mandatory Requirements Check Box (2015 IECC) 2015 IECC 50.5 130.5 151 .0 0.3 104.2 436 .6 As Designed 39.3 103.7 135.8 0.4 122.1 401.3 PASSES PASSES PASSES PASSES PASSES PASSES PASSES PASSES This home MEETS the overall thermal performance requirements and verifications of the International Energy Conservation Code based on a climate zone of 5A. (Section 402, International Energy Conservation Code, 2015 edition.) In fact, this home surpasses the requirements by 8.1%. Name I Paul J. Della Torre Organization Noonan Energy Corp Signature I -f a1JJDA ~ Date 16 January 2019 REM/Rate -Residential Energy Analysis and Rating Software v15.7.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. 2015 IECC Energy Cost .compliance Property Todd G. Cellura 233 Emerson Way Northampton, MA 01062 Weather:Chicopee, MA Todd Cellura Custom Home 0073-0382-C1_Sovereign_Builders Annual Energy Cost Heating Cooling Water Heating Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Sovereign Builders Inc. SubTotal -Used to Determine Compliance Mechanical Ventilation Fan Lights & Appliances (minus MechVent) Photovoltaics Service Charge Total Mandatory Requirements Annual Energy Cost Check Duct Insulation R-Value Check (per Section 405.2) Window U-Value and SHGC Check (per Section 402.5) Home Infiltration (Section 402.4.1) Duct Testing (Section 403.3.3) Mechanical Ventilation (Section 403.6) Mechanical Ventilation Fan Efficacy (Section 403.6.1) Mandatory Requirements Check Box (2015 IECC) HERS Confirmed 2019-01-15 Rating No:0073_0382 Rater ID:8776762 2015 IECC 1070 150 278 1498 40 1138 -0 177 2853 $/yr As Designed 900 111 278 1289 62 986 -0 177 2514 PASSES PASSES PASSES PASSES PASSES PASSES PASSES PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2015 International Energy Conservation Code based on a climate zone of SA. In fact, this home surpasses the requirements by 14.0%. Name I Paul J. Della Torre Organization Noonan Energy Corp Signature 1-Fa..f_[J.DJP.. ~ Date 16 January 2019 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2015 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate -Residential Energy Analysis and Rating Software v15. 7.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2015 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 233 Emerson Way, Northampton, MA by Sovereign Builders Inc. exceeds the minimum requirements for the 2015 International Energy Conservation Code Ceiling Flat R-49.0 Sealed Attic: NA Vaulted Ceiling NA Above Grade Walls R-25.0 Foundation Walls R-13.0 Exposed Floor R-30.0 Slab R-0.0 Edge, R-0.0 Under Building Features Duct NA Duct Leakage to Outside: 0.00 CFM@ 25 Pascals Total Duct Leakage: 218.00 CFM@ 25 Pascals Infiltration: Htg: 756 Clg: 756 CFM50 Window U-Value: 0.300, SHGC: 0.270 Heating Fuel-fired air distribution, Natural gas, 97.0 AFUE. Cooling Air conditioner, Electric, 16.5 SEER. Water Heating Instant water heater, Natural gas, 0. 96 EF, 0.0 Gal. The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in compliance with Chapter 4 based on Climate Zone 5A and with all mandatory requirements. Name I Paul J. Della Torre Organization Noonan Energy Corp Signature 1-f a-{9.DJi ~ Date 16 January 2019 The 2015 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC"). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate -Residential Energy Analysis and Rating Software v15. 7.1 2015 IECC Certificate 233 Emerson Way, Northampton, MA 01062 Building Envelope Insulation Ceiling R-49.0 Above Grade Walls R-25 .0 Foundation Walls R-13.0 Exposed Floor R-30.0 Slab R-0.0 Edge, R-0.0 Under Infiltration Htg: 756 Clg: 756 CFM50 Duct NA Total Duct Leakage 218.00 CFM @ 25 Pascals Window Data U-Factor SHGC Window 0.300 0.270 Mechanicaf"Equipment HEAT: Fuel-fired air distribution, Natural gas, 97.0 AFUE. COOL: Air conditioner, Electric, 16.5 SEER. DHW: Instant water heater, Natural gas, 0. 96 EF, 0.0 Gal. Builder or Design Professional Signature --~_!)_Jg~---_______ _ REM/Rate -Residential Energy Analysis and Rating Software v15.7.1 Property Todd G. Cellura 233 Emerson Way Northampton, MA 01062 Home Energy Rating Certificate HERS Rating Type: Confirmed Certified Energy Rater: Paul J. DellaTorre Rating Date: 2019-01-15 Rating Number: 0073_0382 Registry ID: 072625370 Estimated Annual Energy Cost Use MMBtu Cost HERSlndex:46 Heating 55.6 $739 [ General Information Conditioned Area 3866 sq. ft. House Type Single-family detached Cooling 1. 1 $47 Hot Water 11.3 $157 Conditioned Volume 32861 cubic ft. Foundation Conditioned basement Lights/ Appliances 26.8 $1064 Bedrooms 3 Photovoltaics -0.0 $-0 Service Charges $177 [ Mechanical Systems Features Total 94.8 $2184 Heating: Fuel-fired air distribution, Natural gas, 97.0 AFUE. Cooling: Air conditioner, Electric, 16.5 SEER. Criteria Percent 34% 2% 7% 49% -0% 8% 100% Water Heating: Instant water heater, Natural gas, 0. 96 EF, 0.0 Gal. Duct Leakage to Outside 0.00 CFM25. This home meets or exceeds the minimum criteria for the following: 2015 International Energy Conservation Code Ventilation System Balanced: ERV, 100 cfm, 48.0 watts. Programmable Thermostat Heat=Yes; Cool=Yes [ Building Shell Features Ceiling Flat R-49.0 Sealed Attic NA Vaulted Ceiling NA Above Grade Walls R-25.0 Foundation Walls R-13.0 [ Lights and Appliance Features Interior Fluor Lighting (%) 0.0 Interior LED Lighting (%) 100.0 Refrigerator (kWh/yr) 691 Dishwasher Energy Factor 0.46 Slab Exposed Floor Window Type Infiltration Rate Method R-0.0 Edge, R-0.0 Under R-30.0 U-Value: 0.300, SHGC: 0.270 Htg: 756 Clg: 756 CFM50 Blower door Range/Oven Fuel Natural gas Clothes Dryer Fuel Electric Clothes Dryer CEF 2. 62 Ceiling Fan (cfm/Watt) 0.00 TITLE Company Address City, State, Zip Phone# Fax# REM/Rate -Residential Energy Analysis and Rating Software v15. 7 .1 This information does not constitute any warranty of energy costs or savings.© 1985-2018 NORESCO, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. RESNET HERS Index Certificate HERS®lndex ~ 140 Existing iFif 130 Homes 120 110 Standard H 100 New Home 90 Zero Energy Home __ · 80 70 60 50 40 · 30 20 10 0 ~ More Energy Less Energy 233 Emerson Way Northampton, MA 01062 Rater: Paul J. DellaTorre Registry ID: 072625370 Annual Estimales*: Elec(kWh): 7523 Gas(Therms): 692 CO2 emissions(Tons): 8 Energy Savings ($) .. : 2957 *Based on standard operating conditions **Based on U.S. DOE designation of a HERS Index of 130 as the Typical Existing Home' TITLE Company Address City, State, Zip Phone# This home has been inspected and performance tested in 01:.t'l IEJ® accordance with Chapter 3 of ,-..,,;,rv · the RESNET standards. www.resnet.us