Loading...
41-057 CS Beam Calc-RidgeviewDevLLC-Girder1-Lot12-NorthamptonCS Beam 2016.1.1.1 kmBeamEngine 4.13.16.1 Materials Database 1547 RIDGEVIEW DEVELOPMENT LLC LOT 12 RIDGEVIEW ESTATES NORTHAMPTON, MA 4-23-16 2:24pm 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Bill Lucas Kelly Fradet Lumber 587 North Main St East Longmeadow, Mass 413-785-1558 Member Data Description: GIRDER 1 Member Type: Girder Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total 1.000" max. LL Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 16.2 PLF Filename: Beam1 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Front 0' 0.00" 15' 6.00" 53 18 Live Additional Uniform (PLF) Back 0' 0.00" 15' 6.00" 188 63 Live 1 2 15 6 0 15 6 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF #1/#2 2x or 4x End-Grain (1150psi) 3.500" 1.500" 2519# -- 2 15' 6.000" Wall SPF #1/#2 2x or 4x End-Grain (1150psi) 5.500" 1.500" 2519# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 1795# 724# 2 1795# 724# Design spans 14' 10.750" Product: 2.0 RigidLam LVL 1-3/4 x 9-1/4 4 ply PASSES DESIGN CHECKS Connect members with 2 rows of 1/2" diameter bolts at 24.0" oc Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 9380.'# 27706.'# 33% 7.67' Total Load D+L Shear 2258.# 12518.# 18% 0.23' Total Load D+L Max. Reaction 2519.# 18375.# 13% 0' Total Load D+L TL Deflection 0.4057" 0.7448" L/440 7.67' Total Load D+L LL Deflection 0.2891" 0.4965" L/618 7.67' Total Load L Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 %