Loading...
36-334 Jones_Tina_-_Florence_MA_--_FA_LAYOUTPV-A01 N.T.S. Cover Page Roof Mount Grid Tied Photovoltaic ("PV") System Tina Jones 8.00 kW DC at STC CLIENTPROJECTDRAWING SCALE(11x17")VersDateCommentDRAWN BY:SOLAR LIVING SINCE 1978CONFIDENTIALITY NOTICE: These Plans and any documents transmitted with them may contain PRIVILEGED or CONFIDENTIAL information and may be read or used only by the intended recipient. If you are not the intended recipient, please be advised that you have received this in error and that any unauthorized review, distribution, printing, or copying of these Plans or any attached files is strictly prohibited. PERSPECTIVE VIEW AERIAL VIEW Jones Residence Jennifer BacaTina Jones23 Cardinal Way Florence, MA 010628.00 kWRoof Mount Grid Tied Photovoltaic ("PV") System32 CS5P-250M ModulesInitial Draft103-29-2012Job #: 58138InitJLBInstall Office32 Taugwonk Spur, A12Stonington, CT 06378Tel: 860-535-3370FOR APPROVAL Table Of Contents •PV-A01 Cover Page •PV-A02 Site Plan •PV-A03 Roof Plan •PV-E01 Electrical Diagram System Specifications: •32 Canadian Solar CS5P-250M Modules •2 SMA SB4000US Inverters •Mounted On UniRac Solarmount •Roof Pitch 20 ° •Roof Azimuth 160 ° True Site Conditions: •Ground Snow Load = 55 PSF •Design Wind Speed = 100 MPH and Exposure C •Building Occupancy = II •Mean Roof Height = 15 ft. •Roofing Material is Asphalt Shingle •Framing is 2 X 10 Rafters every 16 in. O.C. Securement Method: •Quantity of Attachments = 116 @ 24 in. O.C. (Limited by Structural/Wind Characteristics) •Maximum UniRac Span = 48 in. O.C. (Maximum Allowable Cantilever is 1/3 the Maximum Rail Span) •UniRac L-Feet with Green-Fasten GF1-CP-SQ Flashing and a 5/16" X 3.5" SSTL Lag Screw •UniRac SolarMount Rails require 1 in. Spacing between Modules and an extra 3 in. beyond end Module edges. •Array Installed according to the UniRac SolarMount Code-Compliant Installation Manual ver. 227.3, Pub 110616-1cc, June 2011 PV-A02 1" = 20' Site Plan CLIENTPROJECTDRAWING SCALE(11x17")VersDateCommentDRAWN BY:SOLAR LIVING SINCE 1978CONFIDENTIALITY NOTICE: These Plans and any documents transmitted with them may contain PRIVILEGED or CONFIDENTIAL information and may be read or used only by the intended recipient. If you are not the intended recipient, please be advised that you have received this in error and that any unauthorized review, distribution, printing, or copying of these Plans or any attached files is strictly prohibited. 32 Canadian Solar CS5P-250M Modules Conduit Run to follow the gutter Main Panel (Interior/Basement) Utility Meter Inverters/Disconnect Location (Exterior) PV-A02 1/8" = 1' 0" Site Plan Jennifer BacaTina Jones23 Cardinal Way Florence, MA 010628.00 kWRoof Mount Grid Tied Photovoltaic ("PV") System32 CS5P-250M ModulesInitial Draft103-29-2012Job #: 58138InitJLBInstall Office32 Taugwonk Spur, A12Stonington, CT 06378Tel: 860-535-3370FOR APPROVAL PV-A03 3/16" = 1'-0" Normal to Roof View CLIENTPROJECTDRAWING SCALE(11x17")VersDateCommentDRAWN BY:SOLAR LIVING SINCE 1978CONFIDENTIALITY NOTICE: These Plans and any documents transmitted with them may contain PRIVILEGED or CONFIDENTIAL information and may be read or used only by the intended recipient. If you are not the intended recipient, please be advised that you have received this in error and that any unauthorized review, distribution, printing, or copying of these Plans or any attached files is strictly prohibited.Jennifer BacaTina Jones23 Cardinal Way Florence, MA 010628.00 kWRoof Mount Grid Tied Photovoltaic ("PV") System32 CS5P-250M ModulesInitial Draft103-29-2012Job #: 58138InitJLBInstall Office32 Taugwonk Spur, A12Stonington, CT 06378Tel: 860-535-3370FOR APPROVAL Module Height: 63.1 inches Module Width:41.8 inches Module Thickness:1.57 inches 60' 6" 18' 6" 10' 7" 57' 0" PV-E01 N.T.S. Electrical Diagram CLIENTPROJECTDRAWING SCALE(11x17")VersDateCommentDRAWN BY:SOLAR LIVING SINCE 1978CONFIDENTIALITY NOTICE: These Plans and any documents transmitted with them may contain PRIVILEGED or CONFIDENTIAL information and may be read or used only by the intended recipient. If you are not the intended recipient, please be advised that you have received this in error and that any unauthorized review, distribution, printing, or copying of these Plans or any attached files is strictly prohibited.Jennifer BacaTina Jones23 Cardinal Way Florence, MA 010628.00 kWRoof Mount Grid Tied Photovoltaic ("PV") System32 CS5P-250M ModulesInitial Draft103-29-2012Job #: 58138InitJLBInstall Office32 Taugwonk Spur, A12Stonington, CT 06378Tel: 860-535-3370FOR APPROVAL LEGEND DC Pos, AC Hot DC Neg, AC Neutral Ground Bonding To Building Grounding ElectrodeSystem 1.All Conductors to be copper unless noted otherwise. 2.Module type is negatively grounded and inverter(s) to be so set. 3.Installation to meet mimimum requirements of the 2008 NEC Except where required otherwise by local code specifications. 4.Interconnect breaker shall be within visual proximity of inverter. 5.Maximum voltage calculated with temperature coefficient of -0.35% /°K 6.All grounding electrode conductors shallbe installed in single continuous lengths except where spliced by irreversible connector or exothermic weld. NOTES LABELINGDC Maximum: 550.97 V, 27.15 A (@ -20° C) DC Operating: 387.20 V, 20.20 A AC Operating: 240 V, 16.67 A 10A Fuses Integrated DC Disconnect SMA Inverter SB 4000US 4.0kW, 16.67A,240VAC UL 1741 Listed IEEE 1547 CompliantDC Ground Fault Protection DC AC 10A Fuses Integrated DC Disconnect SMA Inverter SB 4000US 4.0kW, 16.67A,240VAC UL 1741 Listed IEEE 1547 CompliantDC Ground Fault Protection DC ACJ-Box8-#10 USE-2, #8G ¾" EMT, 8-#10 THWN-2, #10G Locus Lgate 100 Datalogger Internet Connection 120V Outlet 30A 2P AC Combiner Panel Sq. D QO612L100DS 100A Rating 30A 2P Lockable Utility Meter 240V, 200A Utility Service 240VAC,200A Main Load Center Line Tie Within Junction Box Fusible, NEMA-3R Sq. D D222RB 60A Rating Utility Disconnect 60A Fuses 32 Canadian Solar CS5P-250M Modules Voc=59.5 V Isc=5.43 A 4 Strings of 8 Modules Roof Mounted Revenue Grade PV Meter ¾" EMT, 6-#10 THWN-2, #10G ¾" EMT, 3-#6 THWN-2, #10G ¾" EMT, 3-#6 THWN-2