Loading...
22 Arlington Plans 2018-09-181A-5101PROPOSED FLOOR PLAN1/4" = 1'-0"1FAMILY ROOMKITCHENA102BCCDWOOD DECK104BENCHC10'-6"25'-0"22'-0"14'-0"12'-0"5'-0" BOOKCASEPRESSURE-TREATEDSTAIR TO GRADEMASTER BATHROOMWDLOW WALLTALLDRESSERLOW DRESSERKING SIZED BEDTREADMILL5'-4 1/2"FIXED SIDELITEWINDOW4'-10"10"LAUNDRYRELOCATED SLIDER15'-6"5'-0"17'-0"6'-6 1/2"105ART'SCLOSET107SHERRY'SCLOSETMASTER BEDROOM103STORAGECLOSET5'-6"2'-0"5'-1"6'-2 1/2"6 1/2"4 1/2"6 1/2"12'-5"3'-0"3'-0"11'-0"11'-0"11'-0"6 1/2"4 1/2"6 1/2"6 1/2"8'-9"2'-0"4 1/2"4 1/2"6 1/2"6 1/2"4 1/2"6 1/2"12'-1"3'-1 1/4"3'-1 1/4"3'-10"4'-11 1/2"7'-10"3'-10 1/2"2'-4"6'-8"4'-0"4'-0"3'-5 1/2"1064'-4 1/2"4'-4 1/2"5'-3"5'-3"3'-8 1/2"EXISTINGJAMB LOCATION3 1/2"LINE OF OLDDECK4'-0"12'-9"CARPETCARPETHARDWOODFLOORINGHARDWOODFLOORINGCERAMICTILE22" X 30" ACCESS PANEL001BELOWEXISTING HOUSE6- 5- 18FOR REVIEWmlCONSTRUCTASSOCIATES, INC.36 SERVICE CENTERNORTHAMPTON, MA 01060tel: 584-1224 fax: 584-7504PROPOSED PLANSA-11/4" = 1'-0"RENOVATIONS FOR:ART AND SHERRYHYMAN RESIDENCE 22 ARLINGTON STREETNORTHAMPTON, MA 01060BABA123CCDrawn ByDate Issue 1236- 6- 18FOR REVIEW6- 7- 18FOR REVIEW6-14-18FOR REVIEWWindow ScheduleFrame SizeRough OpeningsWindow DataMarkUnit WidthUnit HeightSash OperationJamb DepthR.O. WidthR.O. HeightHead HeightMfrQuantityModel No.CommentsA2'1 5/8"3'8 7/8"DOUBLE HUNG6 9/162'2 1/8"3'8 7/8"6'10"ANDERSEN1TW2036B2'3"2'0"AWNING6 9/162'3"2'0"6'10"PARADIGM12724ALL VINYLC2'9 5/8"3'8 7/8"DOUBLE HUNG6 9/162'10 1/8"3'8 7/8"6'10"ANDERSEN3TW2836D5'7 1/4"3'8 7/8"DOUBLE HUNG6 9/165'7 3/4"3'8 7/8"6'10"ANDERSEN1TW2836-2MULLED UNITE2'1 5/8"5'4 7/8"DOUBLE HUNGVIF2'2 1/8"5'4 7/8"EX'GANDERSEN1TW2052AT FRONT HALLDoor ScheduleFrame SizeRough OpeningsDoor DataMarkUnit WidthUnit HeightJamb DepthR.O. WidthR.O. HeightTypeComments1015'0"6'8"6 9/165'2"6'10"EXISTINGRELOCATEEXISTING DOOR1022'8"6'8"4 9/162'10"6'10"6-PANEL SOLID MOLDED1034'0"6'8"4 9/164'2"6'10"6-PANEL SOLID MOLDEDDOUBLE DOORS1042'8"6'8"4 9/162'10"6'10"6-PANEL SOLID MOLDED1054'0"6'8"4 9/164'2"6'10"6-PANEL SOLID MOLDEDDOUBLE DOORS1062'8"6'8"4 9/162'10"6'10"6-PANEL SOLID MOLDED1072'6"6'8"4 9/165'1 1/4"7'0 1/4"6-PANEL SOLID MOLDEDPOCKET DOOR1083'0"6'8"4 9/163'2"6'10"6-PANEL SOLID MOLDEDBYPASS DOORS AT 1/2 BATH (SEE A-6)0013'0"TBDTBD3'2"TBDEXT. METAL FLUSHHEIGHT TO BE DETERMINED6-19-18FOR REVIEWLOCUS PLAN: NOT TO SCALEARLINGTON AVENUE.± 26'± 8'± 39'NEW ONE-STORYADDITIONNEW WOODDECKNORTHALL ANDERSEN WINDOWS WHITE CLAD EXTERIOR WITH WHITE PREFINISHED INTERIOR, FULL SCREENS, WHITE HARDWARE, NO GRILLES EXISTING TWOSTORY HOUSE82.5'82.5'132'132'7-3-18FOR REVIEW7-12-18FOR REVIEW7-16-18FOR REVIEW7-18-18FOR REVIEWLOT: 10,890 SQ. FT.EXISTING ASPHALTDRIVEWAYLOT: 10,890 SQ. FT.EXISTING COVERAGEHOUSE: 1428DRIVEWAY: 850DECK: 280TOTAL: 2558 SQ. FT.77% OPEN SPACEPROPOSED COVERAGEHOUSE: 1428DRIVEWAY: 850LESS OLDDECK: - 280NEW DECK: 183ADDITION: 683TOTAL: 2864 SQ. FT.74% OPEN SPACE24C-159± 12'8-8-18REVISED 2EAST ELEVATION1/4" = 1'-0"1WEST ELEVATION1/4" = 1'-0"3SOUTH ELEVATION1/4" = 1'-0"IST FLOORFIN.: 100'-0"FIRST FLRCLG: 108'-0"IST FLRFIN.: 100'-0"IST FLRCLG: 108'-0"ASPHALT SHINGLES TO MATCHEXISTING HOUSERIDGE VENTROOF EXTENDS ONTOEXISTING HOUSE ROOFACCDCACCESS DOORS: LOCATE AND SIZETO FIT8'-0"6'-8"ASPHALT SHINGLES TO MATCHEXISTING HOUSERIDGE VENTSIDING TO MATCHEXISTING HOUSE1291294NORTH ELEVATION1/4" = 1'-0"DECKFIN.: 99'-7"IST FLRFIN.: 100'-0"IST FLRCLG: 108'-0"DECKFIN.: 99'-7"IST FLOORFIN.: 100'-0"FIRST FLRCLG: 108'-0"6'-8"BFIBER-CEMENTPANELS AND BATTENSON INFILL WALLFIBER-CEMENTPANELS AND BATTENSON INFILL WALLFIBER-CEMENTPANELS AND BATTENS ONINFILL WALLS127127129129RELOCATED SLIDINGDOOR3'-0"IST FLRFIN.: 100'-0"IST FLRCLG: 108'-0"IST FLRFIN.: 100'-0"IST FLRCLG: 108'-0"SIDING TO MATCHEXISTING HOUSEFIBER-CEMENTPANELS AND BATTENSON INFILL WALLSHELICAL PIER4'-0" MIN.1'-1 1/2"FIBER-CEMENTPANELS AND BATTENSON INFILL WALLSEXISTING HOUSE BEYONDSIDING TO MATCHEXISTING HOUSESIDEWALL EXISTING HOUSEPOURED CONC.FOOTINGASPHALT SHINGLES TO MATCHEXISTING HOUSE0016-20-18FOR REVIEWmlCONSTRUCTASSOCIATES, INC.36 SERVICE CENTERNORTHAMPTON, MA 01060tel: 584-1224 fax: 584-7504ELEVATIONSA-21/4" = 1'-0"RENOVATIONS FOR:ART AND SHERRYHYMAN RESIDENCE 22 ARLINGTON STREETNORTHAMPTON, MA 01060BABA123CCDrawn ByDate Issue 1236-27-18FOR REVIEW7-6-18FOR REVIEW7-16-18FOR REVIEW7-18-18FOR REVIEW8-8-18REVISED FLOOR FRAMING PLAN1/4" = 1'-0"1FAMILY ROOMKITCHEN10'-6 1/2"24'-11"(3) 2 X 12 PTSTRINGERSTO GRADE5'-6"10'-11 1/2"10'-11 1/2"21'-11"8'-2 1/2"14'-0"21'-5 1/2"12'-6 1/2"12'-1"7'-0 1/2"2 X 10 FLOOR JOISTS, 16" ON CENTERS2 X 10 FLOOR JOISTS, 16" ON CENTERS2 X 10 FLOOR JOISTS, 16" ON CENTERS2 X 8 PT FLOOR JOISTS, 16" ON CENTERS3'-7 1/2"(3) 2 X 10 BEAM UNDER(3) 2 X 10 PTBEAM UNDER12'-6 1/2"2 X 10 LEDGER, W/ (2) LEDGERLOK SDS32" ON CENTERS6 X 6 PT POST BELOW, ON HELICAL PIER. SIMPSON CONNECTOR AT TOP, METAL HOLD-DOWN STRAP, TYPICALAT EACH LOCATION(2) 2 X 10 BAND JOISTS, TYPICALFOOTING PLAN1/4" = 1'-0"2FAMILY ROOMKITCHEN8'-1"8'-3"8'-1"5'-3"21'-5"7'-0 1/2"3'-7 1/2"12'-6 1/2"10'-8 1/2"10'-8 1/2"10'-9 1/4"SOLID BRIDGINGSOLID BRIDGINGSOLID BRIDGING1A-51A-X(2) 2 X 8 BAND JOISTS, TYPICAL AT DECK2 X 8 LEDGER, W/ (2) LEDGERLOK SDS 32" ON CENTERS35'-2 1/2"35'-5 1/2"30'-1 1/2"6'-11 3/4"28'-4 3/4"3'-10 1/2"4"1'-7 1/2"DECK FRAMING 5" BELOW ADDITIONFLOOR FRAMING24'-5"(2) 2 X 10 BAND JOIST,TYPICAL12'-3"VERIFY6 X 6 PT POST ON HELICAL PIER. BOTTOM SHOE CONNECTORPROVIDED BY PIER INSTALLER,TOP CONNECTOR SIMPSON OR EQUAL.TYPICAL AT EACH LOCATION. STRAPHOLD DOWN AT PERIMETER POSTS.(3) 2 X 10BEAM UNDER(3) 2 X 10 BEAM UNDERNOT SHOWN:2 X 4 FRAMED SHEAR WALLS BETWEEN POSTS, TYPICAL AT ALL PERIMETER POST LOCATIONS1A-56-27-18FOR REVIEWmlCONSTRUCTASSOCIATES, INC.36 SERVICE CENTERNORTHAMPTON, MA 01060tel: 584-1224 fax: 584-7504FRAMING PLANSA-31/4" = 1'-0"RENOVATIONS FOR:ART AND SHERRYHYMAN RESIDENCE 22 ARLINGTON STREETNORTHAMPTON, MA 01060BABA123CCDrawn ByDate Issue 1237-5-18FOR REVIEW7-7-18FOR REVIEW7-18-18FOR REVIEW ROOF PLAN1/4" = 1'-0"1WOOD DECK BELOWROOF FRAMING PLAN1/4" = 1'-0"2WOOD DECK BELOWWOOD DECK BELOWWOOD TRUSSES, 24" ON CENTERWOOD TRUSSES, 24" ON CENTER20'-11"1'-0"6 1/2"6 1/2"6 1/2"ROOF EXTENDS ONTOEXISTING ROOFSTICK FRAME ONTOEXISTING ROOF:2 X 6, 16" O.C.ASPHALT SHINGLES TOMATCH EXISTING HOUSEASPHALT SHINGLES TOMATCH EXISTING HOUSERIDGE VENTRIDGE VENTALUMINUM GUTTER AND DOWNSPOUT1'-0"1'-0"1'-0"1'-0"1'-0"ALUMINUM GUTTER AND DOWNSPOUTALUMINUM GUTTER AND DOWNSPOUTALUMINUM GUTTER AND DOWNSPOUTHEADER: (2) 2 X 8HEADER: (2) 2 X 8HEADER: (2) 2 X 8HEADER: (2) 2 X 8HEADER: (2) 2 X 81'-0"FIELD-ADDED OVERHANG'LADDER'HEADER: (2) 2 X 82 X 6 BEARINGWALL BELOW2 X 6 BEARINGWALL BELOW2 X 6 BEARINGWALL BELOW1A-51A-5SECOND FLOOR WINDOWMAY REQUIRE NEW, SHORTERUNIT: TO BE DETERMINEDAFTER NEW ROOF IS IN PLACE11'-8"6 1/2"1'-0"6-26-18FOR REVIEWmlCONSTRUCTASSOCIATES, INC.36 SERVICE CENTERNORTHAMPTON, MA 01060tel: 584-1224 fax: 584-7504ROOF PLANSA-41/4" = 1'-0"RENOVATIONS FOR:ART AND SHERRYHYMAN RESIDENCE 22 ARLINGTON STREETNORTHAMPTON, MA 01060BABA123CCDrawn ByDate Issue 1237-18-18FOR REVIEW8-7-18FOR REVIEW BABA123CCDrawn ByDate Issue 123mlCONSTRUCTASSOCIATES, INC.36 SERVICE CENTERNORTHAMPTON, MA 01060tel: 584-1224 fax: 584-7504A-51'-2"1291298'-0" FINISH6'-8" FINISHTRUSS DETAILSBY MANUFACTURER6'-8" FINISHHELICAL FOOTING PIER: LENGTHAND SIZE TO BE ENGINEERED BYPROVIDER/INSTALLER6 x 6 PT POSTPOST CONNECTOR PROVIDEDBY PIER INSTALLERCARPET ON 3/4" T & G PLYWOOD UNDERLAYMENTON 2 X 10 @ 16" CENTERSFLOOR JOISTS1'-0"1/2" GWBSIDING TO MATCH EXISTING HOUSE ON HOUSE- WRAP, ON 1/2" PLY-WOOD SHEATHINGON 2 X 6 WOOD STUDS WITH VAPOR BARRIERAND 1/2" GWBASPHALT SHINGLES TO MATCH EXISTING HOUSE ON 60# FELT AND 5/8" PLYWOOD SHEATHINGON TRUSS ROOF SYSTEM21'-5"10'-8 1/2"10'-8 1/2"SOLID BRIDGING(3) 2 X 10BEAMSOLID BRIDGING(2) 2 X 8 HEADER1 X 8 WATERTABLEMETAL STRAP TIEDOWNSPRAY FOAM INSULATION:R-30 MINIMUMINSULATION: R-21 MINIMUM,TYPE TO BE DETERMINEDINSULATION: R-50 MINIMUM,TYPE TO BE DETERMINED8'-0 3/4" WALL HEIGHT1CROSS SECTION1/2" = 1'-0"(3) 2 X 10BEAM(3) 2 X 10BEAMUNINSULATED SHEAR WALLINFILL AT ALL PERIMETER POSTS: 2 X 4 WOOD STUDS WITH HARDIPANEL SHEATHING AND PVC BATTENS. (NOT SHOWN)SIMPSON POST CONNECTOR,TYPICALSECTION1/2" = 1'-0"RENOVATIONS FOR:ART AND SHERRYHYMAN RESIDENCE 22 ARLINGTON STREETNORTHAMPTON, MA 010607-6-18FOR REVIEW7-18-18FOR REVIEW ELECTRICAL PLAN1/4" = 1'-0"1FAMILY ROOMKITCHENMASTER BATHROOMLAUNDRYCLOSETCLOSETMASTER BEDROOMCLOSETEXISTING SWITCH - FORMERLY USED FOR EXT. SCONCE ELECTRIC KEYSR 3DUPLEX RECEPTACLESURFACE FIXTURERECESSED FIXTURESWITCHTHREE-WAY SWITCHCABLE TELEVISION OUTLETSCONCE FIXTURE 3SMOKE/CO DETECTORCATVFEXHAUST FAN /LIGHT FIXTUREEXTERIOR ADJUSTABLELIGHT- DUAL HEADLINEAR LED W/ MOTION SENSOR CLOSET FIXTUREHALF SWITCHED RECEPTACLENOTE:SPECIAL OUTLETS ONLY SHOWN: OTHERSMAY BE REQUIRED TO CONFORM TO CODE.HALF SWITCHED RECEPTACLECEILING FAN / LIGHTLGFCI220 V RECEPTACLE RSSFLCATV RR RR R SWITCH BELOW TO KEYLESSLAMPHOLDER UNDER STRUCTURE 3 3 3 3BASEBOARD ELECHEATMINI-SPLITAIR HANDLERMINI-SPLIT CONDENSERBELOWSHUT-OFF/JUNCTIONAS REQUIRED6-19-18FOR REVIEWmlCONSTRUCTASSOCIATES, INC.36 SERVICE CENTERNORTHAMPTON, MA 01060tel: 584-1224 fax: 584-7504ELECTRIC PLANE-11/4" = 1'-0"RENOVATIONS FOR:ART AND SHERRYHYMAN RESIDENCE 22 ARLINGTON STREETNORTHAMPTON, MA 01060BABA123CCDrawn ByDate Issue 1237-5-18FOR REVIEW