41-056 CS Beam Calc-RidgeviewDev-F23Beam1-Lot13-NorthamptonCS Beam 2016.7.0.11 kmBeamEngine 2016.7.0.2 Materials Database 1555 RIDGEVIEW DEVELOPMENT LLC LOT 13 RIDGEVIEW ESTATES NORTHAMPTON, MA 9-23-16 12:50pm 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Bill Lucas Kelly Fradet Lumber 587 North Main St East Longmeadow, Mass 413-785-1558 Member Data Description: F23 BEAM 1 Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: (See Below) Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total 1.000" max. LL Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 20.8 PLF Filename: Beam1 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 18' 11.00" 470 118 Live Additional Uniform (PLF) Top 0' 0.00" 7' 6.00" 0 80 Live Additional Uniform (PLF) Top 0' 0.00" 7' 6.00" 250 63 Live Point (LBS) Top 7' 6.00" 4066 1089 Snow 1 2 3 3 7 8 15 3 8 18 11 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall Concrete/Masonry 3.500" 1.500" -- -5718# 2 3' 7.500" Wall Steel 8.000" 3.220" 16907# -- 3 18' 11.000" Wall SPF #1/#2 2x or 4x End-Grain (1150psi) 5.500" 1.500" 3820# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 -3458# -2423# -1306# 2 9892# 5987# 4998# 3 2838# 503# 981# Design spans 3' 4.875" 14' 10.875" Product: 2.0 RigidLam LVL 1-3/4 x 11-7/8 4 ply PASSES DESIGN CHECKS Connect members with 2 rows of 1/2" diameter bolts at 24.0" oc Design assumes continuous lateral bracing along the top chord. No lateral bracing required along the bottom chord. Review gravity uplift reaction force of 5719lbs at bearing 1 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 11953.'# 44258.'# 27% 12.57' Even Spans D+L Negative Moment 21262.'# 50897.'# 41% 3.62' Total Load D+0.75(L+S) Negative Unbrcd 21262.'# 50897.'# 41% 3.62' Total Load D+0.75(L+S) Shear 8452.# 18481.# 45% 3.63' Total Load D+0.75(L+S) Max. Reaction 16907.# 42000.# 40% 3.62' Total Load D+0.75(L+S) TL Deflection 0.2283" 0.7453" L/783 11.08' Even Spans D+0.75(L+S) LL Deflection 0.1644" 0.4969" L/999+ 11.08' Even Spans 0.75(L+S) Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 %