Loading...
41-056 35121-PEACHTREE [LOT 13 RIDGEVIEW ESTATES] - 092316 - DWGS557 North Main Street P.O. Box 277East Longmeadow, MA 01028 Kelly-Fradet Lumber - East Longmeadow (413) 785--1558 WORK ORDER # Attn: 35121 Job:PEACHTREE DESIGN GROUP Ordered On: 09/21/16 LOT 13 RIDGEVIEW ESTATES NORTHAMPTON, MA RIDGEVIEW DEVELOPMENT LLC BILL LUCAS MANUFACTURERS OF ROOF & FLOOR TRUSSES 181 GOODWIN ST PO BOX 51027 INDIAN ORCHARD, MA 01151 Phone (413) 543-1298 Fax (413) 543-1847 Toll Free (800) 456-0187 PO: John GoodrichOur Salesman: Cancellation Date: Sold To: Contractor Copy of Order Phone: Ordered By:BILL LUCAS 09/24/16 ** ** Truss Engineering's Shipping Department should be contacted 5 business days before your optimal delivery date. "Projected Delivery" dates are NOT scheduled ship dates. 10/15/16Projected Delivery By: PLAN HAS BEEN MODIFIED IN ATTEMPT TO MEET CURRENT CODES, ALL FRAMING MUST MATCH AS SHOWN ON TRUSS DRAWINGS. SPECIAL INSTRUCTIONS: QTY TYPE SPAN LUMBER TOP BOT OVRHG / CANT LEFT RIGHT PITCH TOP BOT TRUSS ID TOTALPRICEPRICEUNITPROFILE ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,10.0INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.) PLY O/ABASE SPAN SHIPPING WIDTH UNIT WEIGHT LAYOUT BY:JFG 09/16/16ON: G1 1 8.00 0.00 22-00-00 2 X 4 2 X 6 COMMON 2 Ply 22-00-00 08-05-13 119 G5 1 8.00 0.00 12-05-08 2 X 4 2 X 6 COMMON 2 Ply 12-05-08 05-03-11 63 M1 8.00 0.00 17-03-08 2 X 4 2 X 4 JACK-CLOSED 5 17-03-08 13-01-08 95 M2 8.00 0.00 06-04-00 01-04-002 X 4 2 X 4 MONOPITCH 6 06-04-00 04-09-03 26 M3GE 8.00 0.00 05-04-00 2 X 4 2 X 4 MONOPITCH 1 05-04-00 04-01-03 21 S1 8.00 6.11 43-08-00 01-04-00 01-04-002 X 4 2 X 4 PIGGYBACK 5 43-08-00 13-02-13 195 S1B 8.00 6.11 24-09-08 01-04-002 X 4 2 X 4 ROOF 5 24-09-08 15-01-03 114 S2 8.00 6.11 38-04-00 01-04-00 01-04-00 2 X 4 2 X 4 PIGGYBACK 1 38-04-00 13-02-13 214 S2GE 8.00 6.11 38-04-00 01-04-00 01-04-00 2 X 4 2 X 4 GABLE 1 38-04-00 13-02-13 291 S3 8.00 6.11 36-09-00 01-04-00 2 X 4 2 X 4 PIGGYBACK 5 36-09-00 13-02-13 208 S3GE 8.00 6.11 36-09-00 01-04-00 2 X 4 2 X 4 GABLE 1 36-09-00 13-02-13 321 S4 8.00 6.11 34-08-00 01-04-00 01-04-002 X 4 2 X 4 ROOF 7 34-08-00 12-01-03 142 S4GE 8.00 6.11 34-08-00 01-04-00 01-04-002 X 4 2 X 4 GABLE 1 34-08-00 12-01-03 174 S5 8.00 6.11 14-03-08 00-11-00 00-11-002 X 4 2 X 4 ROOF 3 14-03-08 05-03-11 57 S5B 8.00 6.11 12-05-08 2 X 4 2 X 4 SCISSOR 3 12-05-08 05-03-11 54 S5GE 8.00 6.11 14-03-08 00-11-00 00-11-002 X 4 2 X 4 GABLE 1 14-03-08 05-03-11 59 T1 8.00 0.00 23-10-00 00-11-00 00-11-002 X 4 2 X 4 COMMON 1 23-10-00 08-05-13 105 557 North Main Street P.O. Box 277East Longmeadow, MA 01028 Kelly-Fradet Lumber - East Longmeadow (413) 785--1558 WORK ORDER # Attn: 35121 Job:PEACHTREE DESIGN GROUP Ordered On: 09/21/16 LOT 13 RIDGEVIEW ESTATES NORTHAMPTON, MA RIDGEVIEW DEVELOPMENT LLC BILL LUCAS MANUFACTURERS OF ROOF & FLOOR TRUSSES 181 GOODWIN ST PO BOX 51027 INDIAN ORCHARD, MA 01151 Phone (413) 543-1298 Fax (413) 543-1847 Toll Free (800) 456-0187 PO: John GoodrichOur Salesman: Cancellation Date: Sold To: Contractor Copy of Order Phone: Ordered By:BILL LUCAS 09/24/16 ** ** Truss Engineering's Shipping Department should be contacted 5 business days before your optimal delivery date. "Projected Delivery" dates are NOT scheduled ship dates. 10/15/16Projected Delivery By: QTY TYPE SPAN LUMBER TOP BOT OVRHG / CANT LEFT RIGHT PITCH TOP BOT TRUSS ID TOTALPRICEPRICEUNITPROFILE ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,10.0INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.) PLY O/ABASE SPAN SHIPPING WIDTH UNIT WEIGHT LAYOUT BY:JFG 09/16/16ON: T1GE 8.00 0.00 23-10-00 2 X 4 2 X 4 GABLE 1 23-10-00 08-05-13 114 T2 8.00 0.00 19-01-00 01-04-002 X 4 2 X 4 COMMON 1 19-01-00 07-05-03 83 T2GE 8.00 0.00 19-01-00 2 X 4 2 X 4 GABLE 1 19-01-00 07-05-03 89 T4 8.00 0.00 07-07-00 2 X 4 2 X 4 COMMON 7 07-07-00 06-02-01 43 T5 8.00 0.00 14-03-08 00-11-00 00-11-002 X 4 2 X 4 COMMON 3 14-03-08 05-03-11 56 T5B 8.00 0.00 12-05-08 00-11-00 00-11-00 2 X 4 2 X 4 COMMON 1 12-05-08 05-03-11 55 T5C 8.00 0.00 12-05-08 2 X 4 2 X 4 COMMON 1 12-05-08 05-03-11 52 T5GE 8.00 0.00 14-03-08 2 X 4 2 X 4 GABLE 1 14-03-08 05-03-11 55 TP1 8.00 0.00 04-00-06 2 X 4 2 X 4 PIGGYBACK 13 04-00-06 01-10-05 13 ROOF SUB-TOTAL: QTY NOTES PRICEUNIT TOTALPRICE ITEMS CATEGORYITEM 1 HGUS26-2 Hanger 15 HUS26 Hanger 5 LUS26 Hanger ITEMS SUB-TOTAL: SUB-TOTAL GRAND TOTAL ***** IMPORTANT NOTE ***** It is the sole responsibility of the retailer to supply all attached drawings and information to their customer for review and approval. Any and all changes must be received by Truss Engineering prior to the cancellation date. Any changes received after cancellation date may result in added charges and delay of order. No response before cancellation date will be perceived as a full approval of order. Truss Engineering is responsible for supplying only the material as listed on the order. Deliveries are F.O.B. our truck to jobsite. Inability to access the jobsite or take delivery of order may result in additional charges. *** THESE DRAWINGS HAVE BEEN REVIEWED AND ARE APPROVED AS AN ORDER *** Approved By: Approval Date: PO #:Requested Delivery Date: WIDE LOAD / ESCORT FEE ALL DIMENSIONS SHOWN ARE FEET - INCHES - SIXTEENTHSALL DIMENSIONS SHOWN ARE FACE OF FRAME TO FACE OF TRUSSPLAN HAS BEEN ALTERED IN ATTEMPT TO MEET CURRENT CODEREQUIREMENTS AND TO ALIGN LOAD PATHSFB-1 AND FB-2 FLOOR BEAMS ABOVE BY OTHERSTRUSS DESIGNS BASED ON THE FOLLOWING:ALL EXTERIOR WALLS AND GARAGE WALLS 2x6 FRAMINGFIRST FLOOR WALL HEIGHT 8' 1 1/8" - EXCEPT WHERE NOTEDSECOND FLOOR FRAMING 2x10 WITH 3/4" SUB-FLOORSECOND FLOOR WALL HEIGHT 8' 1 1/8"ROOF PITCH 8/12 WITH INTERIOR CEILING 6.11/12CANTILEVER SOFFIT FRONT AND REAR 16" FROM FRAMECANTILEVER SOFFIT LEFT AND RIGHT 11" FROM FRAMEFB-1FB-2DROPPEDBEAMDROPPEDBEAMDROPPED BEAMTHIS WALL SECTION+1' 8" = 9' 9 1/8"HGUS26-21-04-0032-00-00 4-00-005-00-003-00-008-08-0013-10-00 7-02-00 12-00-00 22-00-0021-08-00 19-00-001-06-0023-06-0014-06-0015-06-0011-06-0012-05-0812-05-0812-06-0012-06-003-00-003-06-0011-06-007-06-0015-06-00This non-structural placement plan is provided for identifying the location of trusses as supplied by Truss Engineering Corporation (TEC). No responsibility is taken or implied by TEC for the structural integrity of thestructure below the trusses or the affects of TEC's product on the structure as a whole. The truss installer shall follow all BCSI recommendations, construction document specifications as well as any site specificrequirements to ensure safe and proper installation. No loading shall be applied to trusses until properly and fully installed, including all sheathing, hangers, wall anchors, lateral web bracing (as shown on individualshop drawings), and permanent bracing (as required by the construction documents). Installation contractor shall refer to the individual truss shop drawings for all structural requirements of trusses, including but notlimited to bearing locations and requirements,plytoplynailing,lateralwebbracing,andtruss spacing. Truss Engineering Corporation strictly adheres to the 'Standard Responsibilities in the Design of Metal PlateConnected Wood Trusses' as defined by TPI Chapter 2(available upon request) regardless of any job specific specifications unless clearly defined otherwise in writing by TEC.This placement plan is Truss Engineering Corporation'sINTERPRETATIONof plans and drawings as supplied to us. The building owner/owner's agent is solely responsible for verifying all dimensions, geometry, loadsand load requirements for accuracy and full compliance to construction documents and shall be responsible for notifying TEC immediately of any discrepancies. The building owner/owner's agent is responsible forcoordinating all construction details between trades. Truss Engineering Corporation isNOTresponsible for field verification of dimensions or special conditions. No trusses supplied by Truss Engineering Corporationmay be cut, drilled, or altered in any way without first contacting TEC and receiving engineering documents allowing such.Order Number: 35121Drawn By:MAQuote Number: Q1609176Job Name:Jobsite:9/23/2016LOT 13 RIDGEVIEW ESTATESJohn GoodrichRIDGEVIEW DEVELOPMENT LLCPEACHTREE DESIGN GROUPNORTHAMPTON ALL DIMENSIONS SHOWN ARE FEET - INCHES - SIXTEENTHSALL DIMENSIONS SHOWN ARE FACE OF FRAME TO FACE OF TRUSSPLAN HAS BEEN ALTERED IN ATTEMPT TO MEET CURRENT CODEREQUIREMENTS AND TO ALIGN LOAD PATHSFB-1 AND FB-2 FLOOR BEAMS ABOVE BY OTHERSTRUSS DESIGNS BASED ON THE FOLLOWING:ALL EXTERIOR WALLS AND GARAGE WALLS 2x6 FRAMINGFIRST FLOOR WALL HEIGHT 8' 1 1/8"SECOND FLOOR FRAMING 2x10 WITH 3/4" SUB-FLOORSECOND FLOOR WALL HEIGHT 8' 1 1/8"ROOF PITCH 8/12 WITH INTERIOR CEILING 6.11/12CANTILEVER SOFFIT FRONT AND REAR 16" FROM FRAMECANTILEVER SOFFIT LEFT AND RIGHT 11" FROM FRAME11-06-0012-05-0819-05-088-06-0812-06-0812-05-0813-00-00This non-structural placement plan is provided for identifying the location of trusses as supplied by Truss Engineering Corporation (TEC). No responsibility is taken or implied by TEC for the structural integrity of thestructure below the trusses or the affects of TEC's product on the structure as a whole. The truss installer shall follow all BCSI recommendations, construction document specifications as well as any site specificrequirements to ensure safe and proper installation. No loading shall be applied to trusses until properly and fully installed, including all sheathing, hangers, wall anchors, lateral web bracing (as shown on individualshop drawings), and permanent bracing (as required by the construction documents). Installation contractor shall refer to the individual truss shop drawings for all structural requirements of trusses, including but notlimited to bearing locations and requirements,plytoplynailing,lateralwebbracing,andtruss spacing. Truss Engineering Corporation strictly adheres to the 'Standard Responsibilities in the Design of Metal PlateConnected Wood Trusses' as defined by TPI Chapter 2(available upon request) regardless of any job specific specifications unless clearly defined otherwise in writing by TEC.This placement plan is Truss Engineering Corporation'sINTERPRETATIONof plans and drawings as supplied to us. The building owner/owner's agent is solely responsible for verifying all dimensions, geometry, loadsand load requirements for accuracy and full compliance to construction documents and shall be responsible for notifying TEC immediately of any discrepancies. The building owner/owner's agent is responsible forcoordinating all construction details between trades. Truss Engineering Corporation isNOTresponsible for field verification of dimensions or special conditions. No trusses supplied by Truss Engineering Corporationmay be cut, drilled, or altered in any way without first contacting TEC and receiving engineering documents allowing such.Order Number: 35121Drawn By:MAQuote Number: Q1609176Job Name:Jobsite:9/23/2016LOT 13 RIDGEVIEW ESTATESJohn GoodrichRIDGEVIEW DEVELOPMENT LLCPEACHTREE DESIGN GROUPNORTHAMPTON ALL DIMENSIONS SHOWN ARE FEET - INCHES - SIXTEENTHSALL DIMENSIONS SHOWN ARE FACE OF FRAME TO FACE OF TRUSSPLAN HAS BEEN ALTERED IN ATTEMPT TO MEET CURRENT CODEREQUIREMENTS AND TO ALIGN LOAD PATHSFB-1 AND FB-2 FLOOR BEAMS ABOVE BY OTHERSTRUSS DESIGNS BASED ON THE FOLLOWING:ALL EXTERIOR WALLS AND GARAGE WALLS 2x6 FRAMINGFIRST FLOOR WALL HEIGHT 8' 1 1/8"SECOND FLOOR FRAMING 2x10 WITH 3/4" SUB-FLOORSECOND FLOOR WALL HEIGHT 8' 1 1/8"ROOF PITCH 8/12 WITH INTERIOR CEILING 6.11/12CANTILEVER SOFFIT FRONT AND REAR 16" FROM FRAMECANTILEVER SOFFIT LEFT AND RIGHT 11" FROM FRAME2x4 LEDGERM3GES3GET2T2GES2S2GES4GET1GET1G1HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HGUS26-2S1B(5)S3(5)S4(7)M2(6)M1(5)TP1(6)TP1(7)S1(5)1-04-0032-00-00 4-00-005-00-003-00-008-08-0013-10-00 7-02-00 12-00-00 22-00-0021-08-00 19-00-001-06-0023-06-0014-06-0015-06-0012-06-001-04-082-00-002-00-002-00-002-00-002-00-001-10-082-00-001-04-001-04-001-04-001-04-001-04-001-04-002-00-002-00-001-11-0016-00-002-00-002-00-002-00-002-00-001-10-081-04-081-10-082-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-00S5GEG5T5GET5BT5CLUS26LUS26LUS26LUS26LUS26S5(3)S5B(3)T5(3)T4(7)2-00-002-00-002-00-002-00-002-00-002-00-001-07-082-00-002-00-002-00-002-00-001-10-084-00-002-00-002-00-002-00-002-00-002-00-002-00-00This non-structural placement plan is provided for identifying the location of trusses as supplied by Truss Engineering Corporation (TEC). No responsibility is taken or implied by TEC for the structural integrity of thestructure below the trusses or the affects of TEC's product on the structure as a whole. The truss installer shall follow all BCSI recommendations, construction document specifications as well as any site specificrequirements to ensure safe and proper installation. No loading shall be applied to trusses until properly and fully installed, including all sheathing, hangers, wall anchors, lateral web bracing (as shown on individualshop drawings), and permanent bracing (as required by the construction documents). Installation contractor shall refer to the individual truss shop drawings for all structural requirements of trusses, including but notlimited to bearing locations and requirements,plytoplynailing,lateralwebbracing,andtruss spacing. Truss Engineering Corporation strictly adheres to the 'Standard Responsibilities in the Design of Metal PlateConnected Wood Trusses' as defined by TPI Chapter 2(available upon request) regardless of any job specific specifications unless clearly defined otherwise in writing by TEC.This placement plan is Truss Engineering Corporation'sINTERPRETATIONof plans and drawings as supplied to us. The building owner/owner's agent is solely responsible for verifying all dimensions, geometry, loadsand load requirements for accuracy and full compliance to construction documents and shall be responsible for notifying TEC immediately of any discrepancies. The building owner/owner's agent is responsible forcoordinating all construction details between trades. Truss Engineering Corporation isNOTresponsible for field verification of dimensions or special conditions. No trusses supplied by Truss Engineering Corporationmay be cut, drilled, or altered in any way without first contacting TEC and receiving engineering documents allowing such.The following information is approximate and NOT guaranteed:Roof Sheathing Area: 3180.52 / Roof Shingles: 34 / Ridge Lines: 103.24 / HipLines: 0Valley Lines: 81.95 / Horizontal Overhang Lines: 130.23 / Raked Overhang Lines: 276.13Order Number: 35121Drawn By:MAQuote Number: Q1609176Job Name:Jobsite:9/23/2016LOT 13 RIDGEVIEW ESTATESJohn GoodrichRIDGEVIEW DEVELOPMENT LLCPEACHTREE DESIGN GROUPNORTHAMPTON Job 35121 Truss G1 Truss Type Common Girder Qty 1 Ply 2 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 13:28:21 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-epBu0J62X6LHAagpl6mHw08lJ?XXv8ja7Qsc6qyalJ8 Scale = 1:52.3 T1 T1 B1 W5 W4 W3W4W3 W1 W2 W1 W2 B2 0-5-8(0-3-15) 5020#/-1247# 0-5-8(0-4-10) 5890#/-724# 1 2 3 4 5 11 10 9 8 7 6 3x6 5x5 3x6 4x6 8x9 4x9 3x8 4x9 3x8 6x10 M18SHS 6x10 M18SHS HGUS26-2 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 5-3-5 5-3-5 11-0-0 5-8-11 16-8-11 5-8-11 22-0-0 5-3-5 5-3-5 5-3-5 11-0-0 5-8-11 16-8-11 5-8-11 22-0-0 5-3-5 1-1-138-5-131-1-138.00 12 Plate Offsets (X,Y)-- [2:0-3-14,0-1-12], [3:0-2-12,0-2-8], [4:0-3-14,0-1-12], [6:0-5-0,0-4-0], [7:0-4-12,0-1-8], [9:0-4-8,0-4-12], [10:0-4-12,0-1-8], [11:0-5-0,0-4-0] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15NOIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.700.660.95 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.13-0.230.06 (loc)7-97-96 l/defl>999>999n/a L/d240180n/a PLATESMT20M18SHS Weight: 238 lb FT = 10% GRIP197/144197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF 1650F 1.5EWEBS2x4 SPF Stud *Except* W1: 2x6 SPF No.2BRACING-TOP CHORDStructural wood sheathing directly applied or 4-10-14 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS 1 Row at midpt 4-6 REACTIONS.(lb/size) 11 =5020/0-5-8 6 =5820/0-5-8Max Horz11 =-186(LC 8)Max Uplift11 =-1247(LC 10)6 =-724(LC 11)Max Grav11 =5020(LC 1)6 =5890(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-2=-1500/466, 2-3=-4544/978, 3-4=-4544/978, 4-5=-1610/283, 1-11=-978/337, 5-6=-1053/234BOT CHORD10-11=-1164/4875, 9-10=-1164/4875, 7-9=-691/5166, 6-7=-691/5166WEBS3-9=-935/4432, 4-9=-2032/141, 4-7=0/2518, 2-9=-1554/664, 2-10=-612/1939, 2-11=-4876/1075, 4-6=-5175/723 NOTES-(19) 1) 2-ply truss to be connected together with 10d (0.120"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc, 2x6 - 3 rows staggered at0-2-0 oc.Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc.Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.2) All loads are considered equally applied to all plies, except if noted as front (F) orback (B) face in the LOAD CASE(S) section. Ply to ply connections have been providedto distribute only loads noted as (F) or (B), unless otherwise indicated.3) This truss has been checked for uniform roof live load only, except as noted.4) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B; partially; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 5) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15);Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.16) Unbalanced snow loads have been considered for this design. 7) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 8) All plates are MT20 plates unless otherwise indicated. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.10) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.11) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 11=1247, 6=724.12) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 14) Use Simpson Strong-Tie HGUS26-2 (20-10d Girder, 6-10d Truss) or equivalent at 1-6-12 from the left end to connect truss(es) S3GE (1 ply 2x4 SPF) to front face of bottom chord. 15) Use Simpson Strong-Tie HUS26 (14-10d Girder, 4-10d Truss, Single Ply Girder) orequivalent spaced at 2-0-0 oc max. starting at 3-5-4 from the left end to 11-5-4 toconnect truss(es) S3 (1 ply 2x4 SPF) to front face of bottom chord. Continued on page 2 Job 35121 Truss G1 Truss Type Common Girder Qty 1 Ply 2 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 13:28:21 2016 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-epBu0J62X6LHAagpl6mHw08lJ?XXv8ja7Qsc6qyalJ8 NOTES-(19) 16) Use Simpson Strong-Tie HUS26 (14-10d Girder, 4-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 13-5-4 from the left end to 21-5-4 to connecttruss(es) M1 (1 ply 2x4 SPF) to front face of bottom chord. 17) Fill all nail holes where hanger is in contact with lumber.18) WARNING: The following hangers are manually applied but fail due to geometricconsiderations: HGUS26-2 on front face at 1-6-12 from the left end.19) All Plates 20 Gauge Unless Noted Job 35121 Truss G5 Truss Type Common Girder Qty 1 Ply 2 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 13:29:00 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-?J2eCeaVL5GlLa9JXozQ?FFXyjubYwZJ5_pAz4yalIX Scale: 3/8"=1' T1 T1 B1 W4 W3W3 W1 W2 W1 W2 0-5-8(0-1-8) 1639#/-336# 0-5-8(0-1-8) 1586#/-325# 1 2 3 4 5 8 7 6 2x4 4x4 2x4 3x8 4x4 4x4 4x6 4x6 LUS26 LUS26 LUS26 LUS26 LUS26 6-2-12 6-2-12 12-5-8 6-2-12 2-8-2 2-8-2 6-2-12 3-6-10 9-9-6 3-6-10 12-5-8 2-8-2 1-1-135-3-111-1-138.00 12 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLLBCDL 35.0 30.8/40.0 10.0 0.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15NOIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.150.470.30 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.03-0.070.01 (loc)7-87-86 l/defl>999>999n/a L/d240180n/a PLATESMT20 Weight: 127 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF Stud *Except* W1: 2x6 SPF No.2BRACING-TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 8 =1510/0-5-8 6 =1461/0-5-8 Max Horz 8 =104(LC 18) Max Uplift8 =-336(LC 10)6 =-325(LC 11)Max Grav8 =1639(LC 2)6 =1586(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 2-3=-1623/368, 3-4=-1623/368 TOP CHORD 2-3=-1623/368, 3-4=-1623/368BOT CHORD7-8=-289/1171, 6-7=-247/1171WEBS3-7=-301/1401, 2-8=-1703/359, 4-6=-1703/360 NOTES-(15)1) 2-ply truss to be connected together with 10d (0.120"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been providedto distribute only loads noted as (F) or (B), unless otherwise indicated.3) This truss has been checked for uniform roof live load only, except as noted.4) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B;partially; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; LumberDOL=1.60 plate grip DOL=1.605) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15);Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 6) Unbalanced snow loads have been considered for this design. 7) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=336, 6=325. 11) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 13) Use Simpson Strong-Tie LUS26 (4-10d Girder, 3-10d Truss, Single Ply Girder) orequivalent spaced at 2-0-0 oc max. starting at 2-0-4 from the left end to 10-0-4 toconnect truss(es) T4 (1 ply 2x4 SPF) to front face of bottom chord. 14) Fill all nail holes where hanger is in contact with lumber.15) All Plates 20 Gauge Unless Noted Job 35121 Truss M1 Truss Type Jack-Closed Qty 5 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:25:28 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-cyiY8BSN4s_d0lkgDDaVVNNyt4omOjEDWvOTB0yamE5 Scale = 1:67.3 W1 T1 W6 B1 W2 W3 W4 W5 T2 935#/-16#1047#/-312# 1 2 3 4 5 8 7 6 3x6 3x6 3x4 3x4 5x5 4x4 3x4 3x4 8-3-6 8-3-6 17-3-8 9-0-2 5-7-13 5-7-13 11-3-8 5-7-10 17-3-8 6-0-0 1-7-313-1-88.00 12 Plate Offsets (X,Y)-- [4:0-1-12,0-1-8], [6:0-2-8,0-2-12] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.740.730.92 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.29-0.540.02 (loc)6-76-76 l/defl>701>381n/a L/d240180n/a PLATESMT20 Weight: 95 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2WEBS2x4 SPF Stud *Except* W6,W4,W5: 2x4 SPF No.2BRACING-TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 9-10-12 oc bracing.WEBS 1 Row at midpt 5-6, 4-6 REACTIONS.(lb/size) 8 =864/Mechanical 6 =864/MechanicalMax Horz8 =428(LC 11)Max Uplift8 =-16(LC 11)6 =-312(LC 11)Max Grav8 =935(LC 2)6 =1047(LC 15) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-8=-301/157, 1-2=-266/136, 2-4=-847/30, 5-6=-312/130BOT CHORD7-8=-343/734, 6-7=-183/447WEBS2-8=-835/0, 2-7=-299/267, 4-7=-141/560, 4-6=-791/328 NOTES-(12) 1) This truss has been checked for uniform roof live load only, except as noted. 2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B; partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 12-10-13, Exterior(2) 12-10-13 to 17-1-12 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.60 plate grip DOL=1.603) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15);Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 16 lb uplift at joint 8 and 312 lb uplift at joint 6. 10) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) All Plates 20 Gauge Unless Noted Job 35121 Truss M2 Truss Type Monopitch Qty 6 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 09:52:14 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-pAAqXSBIG?e8?qtgdJeTtYasrw2ZDmIxMVGyUwyaoTl Scale = 1:26.4 T1 W3 B1 W2W1 0-3-0(0-1-8) 445#/-48# 0-1-8(0-1-8) 247#/-146# 1 2 3 5 42.5x4 1.5x4 3x4 1x4 4x4 1-4-0 1-4-0 1-5-8 0-1-8 6-4-0 4-10-8 6-4-0 6-4-0 0-6-84-9-34-5-110-3-84-9-38.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.370.160.08 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.02-0.04-0.00 (loc)4-54-54 l/defl>999>999n/a L/d240180n/a PLATESMT20 Weight: 27 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2WEBS2x4 SPF StudBRACING-TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 5 =411/0-3-0 4 =217/0-1-8 Max Horz 5 =194(LC 11) Max Uplift5 =-48(LC 11)4 =-146(LC 12)Max Grav5 =445(LC 2)4 =247(LC 16) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.WEBS 2-5=-346/120 WEBS2-5=-346/120 NOTES-(13)1) This truss has been checked for uniform roof live load only, except as noted.2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B;partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left andright exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.8) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grainformula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 48 lb uplift at joint 5 and 146 lb uplift at joint 4.11) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 13) All Plates 20 Gauge Unless Noted Job 35121 Truss M3GE Truss Type Monopitch Supported Gable Qty 1 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 13:25:00 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-18YvqahzsM0oYhpBTOg8GdJYDz3lJSP_vegTY_yalMH Scale = 1:22.5 T1 W1 B1 ST2 ST11 2 3 4 7 6 5 2.5x4 1.5x4 1.5x4 1x4 1x4 1x4 1x4 4-0-0 5-4-0 5-4-0 5-4-0 5-4-0 0-6-84-1-38.00 12 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLLBCDL 35.0 30.8/40.0 10.0 0.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.110.130.03 DEFL.Vert(LL)Vert(TL)Horz(TL) inn/an/a-0.00 (loc)- - 5 l/defln/an/an/a L/d999999n/a PLATESMT20 Weight: 21 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2OTHERS2x4 SPF No.2BRACING-TOP CHORDStructural wood sheathing directly applied or 5-4-0 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size) 5 =82/4-0-0 6 =174/4-0-0 7 =271/4-0-0 Max Horz 7 =164(LC 11)Max Uplift5 =-25(LC 11)6 =-191(LC 12)Max Grav5 =95(LC 15)6 =190(LC 15)7 =293(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(14) 1) This truss has been checked for uniform roof live load only, except as noted.2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B;partially; MWFRS (low-rise) automatic zone and C-C Corner(3) zone; cantilever left andright exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15);Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.15) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.7) Gable studs spaced at 2-0-0 oc.8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) 5 except (jt=lb) 6=191.11) Non Standard bearing condition. Review required.12) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 14) All Plates 20 Gauge Unless Noted Job 35121 Truss S1 Truss Type Piggyback Base Qty 5 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 13:13:32 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-AnzpRKMPuzLQ0zDyAvKoOYpqSe6x66Ejic03PsyalX1 Scale = 1:75.0 T2 T3 T2 B1 B3 B4 B5 B6 W1 W2 W3 W4 W5 W6 W7 W8 W9 W10 W11 W12 W13 W14 T1 T1B2 0-5-8(0-2-5)1474#/-271#0-5-8(0-3-7)2182#/-179#0-3-0(0-1-8)240#/-173# 1 2 3 4 5 6 7 8 9 10 11 1213 22 21 2019 18 17 16 15 14 3x6 5x5 5x5 3x6 3x6 5x6 4x6 5x9 4x6 3x4 5x8 M18SHS 3x6 4x6 5x6 3x4 3x4 3x4 3x4 3x6 4x4 3x4 1.5x4 1-4-0 1-4-0 1-9-8 0-5-8 7-6-8 5-9-0 13-0-6 5-5-14 19-4-0 6-3-10 24-7-8 5-3-8 33-10-8 9-3-0 34-1-4 0-2-12 42-2-8 8-1-4 42-4-0 0-1-8 43-8-0 1-4-0 1-9-8 1-9-8 6-10-12 5-1-4 13-0-6 6-1-10 19-0-8 6-0-2 24-7-8 5-7-0 30-2-14 5-7-6 33-10-8 3-7-10 38-3-12 4-5-5 42-2-8 3-10-12 43-8-0 1-5-8 0-6-813-2-130-6-88-11-31-6-513-2-138.00 12 6.11 12 Plate Offsets (X,Y)-- [2:0-2-4,0-1-12], [3:0-1-12,0-1-8], [5:0-1-12,0-1-8], [7:0-3-0,0-2-0], [9:0-2-0,0-1-4], [16:0-3-8,0-2-4], [18:0-3-4,0-3-8], [21:0-3-0,0-2-4] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 1-4-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.650.760.72 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.38-0.640.52 (loc)1918-1915 l/defl>999>600n/a L/d240180n/a PLATESMT20M18SHS Weight: 196 lb FT = 10% GRIP197/144197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E *Except* B5,B6: 2x4 SPF No.2WEBS2x4 SPF No.2 *Except* W1,W14: 2x4 SPF StudBRACING-TOP CHORDStructural wood sheathing directly applied or 2-10-14 oc purlins, except 2-0-0 oc purlins (4-2-0 max.): 6-7.BOT CHORD Rigid ceiling directly applied or 2-11-12 oc bracing. WEBS 1 Row at midpt 8-16 REACTIONS.(lb/size)22 =1166/0-5-815 =1604/0-5-814 =188/0-3-0Max Horz22 =223(LC 10)Max Uplift22 =-271(LC 11)15 =-179(LC 11) 14 =-173(LC 12) Max Uplift22 =-271(LC 11)15 =-179(LC 11)14 =-173(LC 12)Max Grav22 =1474(LC 23)15 =2182(LC 23)14 =240(LC 27) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3387/557, 3-5=-4068/637, 5-6=-3085/492, 6-7=-2509/455, 7-8=-1552/306, 8-9=-23/557, 9-11=-30/490 BOT CHORD21-22=-232/268, 19-21=-694/3115, 18-19=-670/3676, 17-18=-144/1317, 16-17=-35/601, 15-16=-1976/218, 9-16=-321/103WEBS2-22=-1351/303, 2-21=-419/2946, 3-21=-691/148, 3-19=0/514, 5-18=-851/292, 6-18=-135/1307, 7-18=-324/1681, 7-17=-561/158,8-17=-105/720, 8-16=-2047/193, 11-15=-270/110, 11-14=-13/279 NOTES-(14) 1) This truss has been checked for uniform roof live load only, except as noted.2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B;partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-0-0 to 4-4-6, Interior(1) 4-4-6 to 12-10-6, Exterior(2) 12-10-6 to 30-9-10, Interior(1) 30-9-10 to 39-3-10 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-04) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.6) Provide adequate drainage to prevent water ponding.7) All plates are MT20 plates unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 22=271, 15=179, 14=173.11) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. Continued on page 2 Job 35121 Truss S1 Truss Type Piggyback Base Qty 5 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 13:13:32 2016 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-AnzpRKMPuzLQ0zDyAvKoOYpqSe6x66Ejic03PsyalX1 NOTES-(14) 12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 13) Graphical purlin representation does not depict the size or the orientation of the purlinalong the top and/or bottom chord.14) All Plates 20 Gauge Unless Noted Job 35121 Truss S1B Truss Type ROOF SPECIAL Qty 5 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 13:13:44 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-p5iLyRVx3fsjSp7GtQXct4JusTGtwXlUSTwipAyalWr Scale = 1:85.6 T2 T3 B1 B3 B4 W1 W2 W3 W4 W5 W6 W7 W8 W10W9 T1 0-5-8(0-2-5)1462#/-175#0-5-8(0-1-15)1249#/-356# 1 2 3 4 5 6 7 8 14 13 1211 10 9 3x6 5x6 2.5x4 3x4 5x5 4x6 5x8 3x8 4x6 3x4 3x4 3x4 1.5x4 3x4 1-4-0 1-4-0 1-9-8 0-5-8 6-10-13 5-1-5 13-0-7 6-1-10 19-3-14 6-3-7 24-9-8 5-5-10 1-9-8 1-9-8 6-10-13 5-1-5 13-0-7 6-1-10 19-3-14 6-3-7 21-10-0 2-6-2 24-9-8 2-11-8 0-6-815-1-34-2-68-11-28.00 12 6.11 12 Plate Offsets (X,Y)-- [1:0-0-0,0-0-10], [2:0-3-0,0-1-8], [3:0-1-12,0-1-8], [5:0-1-12,0-1-8], [7:0-3-12,0-2-4], [10:0-2-12,0-2-4], [13:0-2-12,0-1-12], [14:0-2-0,0-2-8] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.620.500.82 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.20-0.390.19 (loc)11-1311-139 l/defl>999>710n/a L/d240180n/a PLATESMT20 Weight: 114 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B3,B2: 2x4 SPF 1650F 1.5EWEBS2x4 SPF No.2 *Except* W1: 2x4 SPF StudBRACING-TOP CHORDStructural wood sheathing directly applied or 2-9-1 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size) 14 =1350/0-5-8 9 =1154/0-5-8 Max Horz14 =500(LC 10)Max Uplift14 =-175(LC 11)9 =-356(LC 12)Max Grav14 =1462(LC 2)9 =1249(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD2-3=-2897/696, 3-5=-2971/733, 5-6=-1732/443, 6-7=-1669/586BOT CHORD13-14=-539/0, 11-13=-1067/2616, 10-11=-942/2665, 9-10=-157/520WEBS2-14=-1335/424, 2-13=-541/2466, 3-13=-527/201, 5-11=0/254, 5-10=-1047/400, 6-10=-438/235, 7-10=-656/1915, 7-9=-1163/357 NOTES-(11) 1) This truss has been checked for uniform roof live load only, except as noted. 2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B; partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 18-10-0, Exterior(2) 18-10-0 to 21-10-0 zone; cantilever left and rightexposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.60 plate grip DOL=1.603) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15);Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 14=175, 9=356. 9) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 11) All Plates 20 Gauge Unless Noted Job 35121 Truss S2 Truss Type Piggyback Base Qty 1 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 13:19:02 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-VGvZhALPAMwbcgROVCFBm8UAnfhkRKxIayyX_kyalRt Scale = 1:76.1 T2 T3 T4 B1 B2 B3 B4 B5W1W2W3 W4 W5 W6 W7 W10 W9 W8 W11 W13 W12 T1 0-5-8(0-3-4)2084#/-357#0-3-0(0-1-8)509#/-165#0-5-8(0-4-4)2711#/-461# 1 2 3 4 5 6 7 8 9 10 1112 20 19 18 17 16 15 14 13 3x6 5x8 M18SHS 3x6 2.5x4 4x6 2x4 3x4 3x8 M18SHS 1.5x4 3x4 4x4 5x8 M18SHS 3x6 3x4 5x6 12x12 3x6 5x6 4x9 1-4-0 1-4-0 1-5-8 0-1-8 9-6-12 8-1-4 9-9-8 0-2-12 19-0-8 9-3-0 22-10-0 3-9-8 24-7-8 1-9-8 31-7-15 7-0-7 38-4-0 6-8-1 1-5-8 1-5-8 5-4-4 3-10-12 9-9-8 4-5-5 13-5-2 3-7-10 19-0-8 5-7-6 22-10-0 3-9-8 24-7-8 1-9-8 31-7-15 7-0-7 38-4-0 6-8-1 39-8-0 1-4-0 0-6-813-2-134-1-38-2-01-6-513-2-138.00 12 6.11 12 Plate Offsets (X,Y)-- [1:Edge,0-0-10], [7:0-3-12,0-2-0], [9:0-4-4,Edge], [11:0-3-0,0-1-12], [14:0-3-0,0-1-12], [16:0-3-15,0-6-0], [18:0-3-8,0-2-8], [19:Edge,0-2-12] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.860.910.85 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.29-0.600.27 (loc)14-1514-1513 l/defl>999>569n/a L/d240180n/a PLATESMT20M18SHS Weight: 214 lb FT = 10% GRIP197/144197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E *Except* T4: 2x4 SPF 2100F 1.8EBOT CHORD 2x4 SPF No.2 *Except* B2: 2x4 SPF StudWEBS2x4 SPF No.2 *Except* W1,W7,W9,W11,W12: 2x4 SPF StudWEDGELeft: 2x4 SPF StudBRACING-TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-0-4 max.): 7-9. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 18-19.WEBS1 Row at midpt 6-18, 10-14 REACTIONS.(lb/size)13 =1543/0-5-820 =470/0-3-019 =1988/0-5-8Max Horz 20 =357(LC 10) Max Horz20 =357(LC 10)Max Uplift13 =-357(LC 12)20 =-165(LC 9)19 =-461(LC 10)Max Grav13 =2084(LC 24)20 =509(LC 2) 19 =2711(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-5=-228/344, 5-6=-132/373, 6-7=-2196/443, 7-8=-2525/499, 8-9=-2520/497, 9-10=-3006/479, 10-11=-1716/342, 11-13=-2032/413BOT CHORD18-19=-2422/368, 5-18=-504/144, 17-18=-188/1085, 16-17=-196/1819, 8-16=-403/194WEBS3-20=-203/289, 3-19=-349/201, 6-18=-2549/379, 6-17=-9/796, 7-17=-533/96, 7-16=-128/1396, 14-16=-202/1730, 9-16=-139/907, 10-16=-140/970, 10-14=-1736/312, 11-14=-158/1418 WEBS3-20=-203/289, 3-19=-349/201, 6-18=-2549/379, 6-17=-9/796, 7-17=-533/96, 7-16=-128/1396, 14-16=-202/1730, 9-16=-139/907,10-16=-140/970, 10-14=-1736/312, 11-14=-158/1418 NOTES-(15)1) This truss has been checked for uniform roof live load only, except as noted.2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B;partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-0-0 to 3-10-0, Interior(1) 3-10-0 to 13-7-7, Exterior(2) 13-7-7 to 30-0-9, Interior(1) 30-0-9 to 35-10-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-04) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.6) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.7) Provide adequate drainage to prevent water ponding.8) All plates are MT20 plates unless otherwise indicated. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.Continued on page 2 Job 35121 Truss S2 Truss Type Piggyback Base Qty 1 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 13:19:03 2016 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-zTTxvWM1xg2SDq0a3wmQIL1LX31zAnBRpch4WAyalRs NOTES-(15) 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and anyother members, with BCDL = 10.0psf.11) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 13=357, 20=165, 19=461.12) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 15) All Plates 20 Gauge Unless Noted Job 35121 Truss S2GE Truss Type GABLE Qty 1 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 13:24:42 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-YhS52QTg5qlMOwRkQcLwYqZH_jkH566LmrJWw1yalMZ Scale = 1:76.1 T2 T3 T4 B1 B2 B3 B4 B5W1 W2 W3 W4 W5 W6 W7 W10 W9 W8 W11 W13 W12 T1 ST11 ST10 ST9 ST7 ST8ST6 ST5 ST4ST3 ST2ST1 ST12 ST13 ST14 ST15 ST16 ST17 ST18 ST19 0-5-8(0-3-4)2084#/-357#0-3-0(0-1-8)509#/-165#0-5-8(0-4-4)2711#/-461# 1 2 3 4 5 6 7 8 9 10 1112 20 19 18 17 16 15 14 13 3x6 5x8 M18SHS 3x6 2.5x4 4x6 2x4 3x4 3x8 M18SHS 3x4 4x4 5x8 M18SHS 3x6 3x4 5x6 12x12 3x6 5x6 4x9 1-4-0 1-4-0 1-5-8 0-1-8 9-6-12 8-1-4 9-9-8 0-2-12 19-0-8 9-3-0 22-10-0 3-9-8 24-7-8 1-9-8 31-7-15 7-0-7 38-4-0 6-8-1 1-5-8 1-5-8 5-4-4 3-10-12 9-9-8 4-5-5 13-5-2 3-7-10 19-0-8 5-7-6 22-10-0 3-9-8 24-7-8 1-9-8 31-7-15 7-0-7 38-4-0 6-8-1 39-8-0 1-4-0 0-6-813-2-134-1-38-2-01-6-513-2-138.00 12 6.11 12 Plate Offsets (X,Y)-- [1:Edge,0-0-10], [7:0-3-12,0-2-0], [9:0-4-4,Edge], [11:0-3-0,0-1-12], [14:0-3-0,0-1-12], [16:0-3-15,0-6-0], [18:0-3-8,0-2-8], [19:Edge,0-2-12], [22:0-2-0,0-0-5], [27:0-1-15,0-0-12], [46:0-1-8,0-0-12] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.860.910.85 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.29-0.600.27 (loc)14-1514-1513 l/defl>999>569n/a L/d240180n/a PLATESMT20M18SHS Weight: 291 lb FT = 10% GRIP197/144197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E *Except* T4: 2x4 SPF 2100F 1.8EBOT CHORD 2x4 SPF No.2 *Except* B2: 2x4 SPF StudWEBS2x4 SPF No.2 *Except* W1,W7,W9,W11,W12: 2x4 SPF StudOTHERS2x4 SPF StudBRACING-TOP CHORDStructural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-0-4 max.): 7-9. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 18-19. WEBS1 Row at midpt 6-18, 10-14 REACTIONS.(lb/size)13 =1543/0-5-820 =470/0-3-019 =1988/0-5-8Max Horz20 =357(LC 10) Max Uplift 13 =-357(LC 12) Max Uplift20 =-165(LC 9)19 =-461(LC 10)Max Grav13 =2084(LC 24)20 =509(LC 2)19 =2711(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-5=-228/344, 5-6=-132/373, 6-7=-2196/443, 7-8=-2525/499, 8-9=-2520/497, 9-10=-3006/479, 10-11=-1716/342, 11-13=-2032/413 BOT CHORD18-19=-2422/368, 5-18=-504/144, 17-18=-188/1085, 16-17=-196/1819, 8-16=-403/194WEBS3-20=-203/289, 3-19=-349/201, 6-18=-2549/379, 6-17=-9/796, 7-17=-533/96, 7-16=-128/1396, 14-16=-202/1730, 9-16=-139/907,10-16=-140/970, 10-14=-1736/312, 11-14=-158/1418 NOTES-(18) 1) This truss has been checked for uniform roof live load only, except as noted. 2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B;partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-0-0 to 3-10-0,Interior(1) 3-10-0 to 13-7-7, Exterior(2) 13-7-7 to 30-0-9, Interior(1) 30-0-9 to 35-10-0zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15);Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-05) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.7) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.8) Provide adequate drainage to prevent water ponding. 9) All plates are MT20 plates unless otherwise indicated. 10) All plates are 1.5x4 MT20 unless otherwise indicated. 11) Gable studs spaced at 2-0-0 oc. 12) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads.13) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.Continued on page 2 Job 35121 Truss S2GE Truss Type GABLE Qty 1 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 13:24:42 2016 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-YhS52QTg5qlMOwRkQcLwYqZH_jkH566LmrJWw1yalMZ NOTES-(18) 14) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 13=357, 20=165, 19=461.15) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.16) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 17) Graphical purlin representation does not depict the size or the orientation of the purlinalong the top and/or bottom chord.18) All Plates 20 Gauge Unless Noted Job 35121 Truss S3 Truss Type Piggyback Base Qty 5 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:26:23 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-VXXKh?7t7mwp6CRFxG3OEz8I3Fd5ndqJAzDtcKyamDE Scale = 1:77.1 T1 T3 T4 B1 B3 B4 B5 W3 W4 W5 W6 W8W7 W9 W10 W1 W2 W12 W11 B2 T2 0-5-8(0-1-13)1171#/-323#0-5-8(0-5-0)3194#/-317# 733#/-206# 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 3x6 3x6 7x8 5x8 M18SHS 3x6 5x8 5x6 3x4 3x4 4x4 3x4 3x6 5x8 3x6 3x6 6x6 1-8-08-3-5 8-3-5 17-3-8 9-0-3 23-9-8 6-6-0 30-0-8 6-3-0 36-9-0 6-8-8 5-7-13 5-7-13 11-3-7 5-7-10 17-5-8 6-2-1 23-0-8 5-7-0 30-1-8 7-1-0 36-9-0 6-7-8 38-1-0 1-4-0 1-7-313-2-132-5-31-8-03-2-31-5-313-2-138.00 12 6.11 12 Plate Offsets (X,Y)-- [4:0-1-12,0-1-8], [6:0-3-8,0-2-4], [11:0-3-0,0-3-0], [12:0-1-9,0-2-12], [13:0-1-12,0-2-0], [14:0-2-12,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.990.570.79 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.20-0.350.12 (loc)14-1614-1610 l/defl>999>587n/a L/d240180n/a PLATESMT20M18SHS Weight: 208 lb FT = 10% GRIP197/144197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* T3: 2x6 SPF No.2, T4: 2x4 SPF 1650F 1.5EBOT CHORD 2x4 SPF No.2 *Except* B3: 2x6 SPF No.2WEBS2x4 SPF No.2 *Except* W3,W10,W2,W11: 2x4 SPF Stud, W6: 2x4 SPF 1650F 1.5EBRACING-TOP CHORDStructural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins(6-0-0 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except: 1 Row at midpt 6-12 WEBS 1 Row at midpt 4-14, 7-122 Rows at 1/3 pts 5-14 REACTIONS.(lb/size)10 =842/0-5-814 =2410/0-5-817 =575/MechanicalMax Horz17 =308(LC 10) Max Uplift 10 =-323(LC 12) Max Uplift14 =-317(LC 10)17 =-206(LC 11)Max Grav10 =1171(LC 24)14 =3194(LC 24)17 =733(LC 26) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-262/140, 2-4=-588/331, 4-5=0/851, 5-6=-100/368, 6-7=-354/347, 7-8=-1685/408, 1-17=-298/159, 8-10=-1162/370 BOT CHORD 16-17=-297/539, 13-14=-507/99, 12-13=-1186/160, 6-12=-558/64,11-12=-228/1408WEBS2-16=-461/238, 4-16=-120/652, 4-14=-1150/303, 5-14=-2066/169,5-13=-149/1342, 7-12=-1709/351, 7-11=-59/962, 2-17=-591/187,8-11=-178/1111 NOTES-(17)1) This truss has been checked for uniform roof live load only, except as noted. 2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B;partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-1-12 to 3-9-14,Interior(1) 3-9-14 to 12-3-2, Exterior(2) 12-3-2 to 28-2-14, Interior(1) 28-2-14 to 34-4-14zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.6) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.7) Provide adequate drainage to prevent water ponding.8) All plates are MT20 plates unless otherwise indicated. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 11) Refer to girder(s) for truss to truss connections.12) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle tograin formula. Building designer should verify capacity of bearing surface.13) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 323 lb uplift at joint 10, 317 lb uplift at joint 14 and 206 lb uplift at joint 17.Continued on page 2 Job 35121 Truss S3 Truss Type Piggyback Base Qty 5 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:26:23 2016 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-VXXKh?7t7mwp6CRFxG3OEz8I3Fd5ndqJAzDtcKyamDE NOTES-(17) 14) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.15) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 16) Graphical purlin representation does not depict the size or the orientation of the purlinalong the top and/or bottom chord.17) All Plates 20 Gauge Unless Noted Job 35121 Truss S3GE Truss Type GABLE Qty 1 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:26:37 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-5ENddnHfq3gqoMWxmCKgowkhXuOM3zINO8cc6WyamD0 Scale = 1:77.1 T1 T3 T4 B1 B3 B4 B5 W3 W4 W5 W6 W8W7 W9 W10 W1 W2 W12W11 B2 T2 ST15 ST16 ST13 ST14 ST11 ST12 ST9 ST10 ST8ST6 ST7 ST4 ST5ST3ST2ST1 ST17 ST18 ST19 ST20 ST21 ST22 ST23 ST24 ST25 ST26 0-5-8(0-1-13)1171#/-323#0-5-8(0-5-0)3194#/-317# 733#/-206# 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 3x6 3x6 7x8 5x8 M18SHS 3x6 5x8 5x6 3x4 3x4 4x4 3x4 3x6 5x8 3x6 3x6 6x6 2x4 2x4 2x4 2x4 2x4 1-8-08-3-5 8-3-5 17-3-8 9-0-3 23-9-8 6-6-0 30-0-8 6-3-0 36-9-0 6-8-8 5-7-13 5-7-13 11-3-7 5-7-10 17-5-8 6-2-1 23-0-8 5-7-0 30-1-8 7-1-0 36-9-0 6-7-8 38-1-0 1-4-0 1-7-313-2-132-5-31-8-03-2-31-5-313-2-138.00 12 6.11 12 Plate Offsets (X,Y)-- [4:0-1-12,0-1-8], [6:0-3-8,0-2-4], [11:0-3-0,0-3-0], [12:0-1-9,0-2-12], [13:0-1-12,0-2-0], [14:0-2-12,0-1-8], [57:0-1-9,0-0-12] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.990.570.79 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.20-0.350.12 (loc)14-1614-1610 l/defl>999>587n/a L/d240180n/a PLATESMT20M18SHS Weight: 322 lb FT = 10% GRIP197/144197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* T3: 2x6 SPF No.2, T4: 2x4 SPF 1650F 1.5EBOT CHORD 2x4 SPF No.2 *Except* B3: 2x6 SPF No.2WEBS2x4 SPF No.2 *Except* W3,W10,W2,W11: 2x4 SPF Stud, W6: 2x4 SPF 1650F 1.5EOTHERS2x4 SPF Stud *Except* ST14,ST17: 2x4 SPF No.2BRACING-TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except: 1 Row at midpt 6-12WEBS1 Row at midpt 4-14, 7-122 Rows at 1/3 pts 5-14 REACTIONS.(lb/size)10 =842/0-5-814 =2410/0-5-817 =575/Mechanical Max Horz 17 =308(LC 10) Max Horz17 =308(LC 10)Max Uplift10 =-323(LC 12)14 =-317(LC 10)17 =-206(LC 11)Max Grav10 =1171(LC 24)14 =3194(LC 24) 17 =733(LC 26) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-262/140, 2-4=-588/331, 4-5=0/851, 5-6=-100/368, 6-7=-354/347, 7-8=-1685/408, 1-17=-298/159, 8-10=-1162/370BOT CHORD16-17=-297/539, 13-14=-507/99, 12-13=-1186/160, 6-12=-558/64,11-12=-228/1408WEBS2-16=-461/238, 4-16=-120/652, 4-14=-1150/303, 5-14=-2066/169,5-13=-149/1342, 7-12=-1709/351, 7-11=-59/962, 2-17=-591/187,8-11=-178/1111 NOTES-(20) 1) This truss has been checked for uniform roof live load only, except as noted.2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B;partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-1-12 to 3-9-14, Interior(1) 3-9-14 to 12-3-2, Exterior(2) 12-3-2 to 28-2-14, Interior(1) 28-2-14 to 34-4-14 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, orconsult qualified building designer as per ANSI/TPI 1.4) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15);Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-05) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.7) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 8) Provide adequate drainage to prevent water ponding. 9) All plates are MT20 plates unless otherwise indicated. 10) All plates are 1.5x4 MT20 unless otherwise indicated.11) Gable studs spaced at 2-0-0 oc.12) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. Continued on page 2 Job 35121 Truss S3GE Truss Type GABLE Qty 1 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:26:37 2016 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-5ENddnHfq3gqoMWxmCKgowkhXuOM3zINO8cc6WyamD0 NOTES-(20) 13) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and anyother members, with BCDL = 10.0psf.14) Refer to girder(s) for truss to truss connections.15) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grainformula. Building designer should verify capacity of bearing surface.16) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 323 lb uplift at joint 10, 317 lb uplift at joint 14 and 206 lb uplift at joint 17.17) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 18) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 19) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.20) All Plates 20 Gauge Unless Noted Job 35121 Truss S4 Truss Type Roof Special Qty 7 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:45:09 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-X9Z?00lAxjn2CFXfvlGRsQnpq9vNbtb259_S73yalxe Scale = 1:68.4 T1 T2 B1 B2 B2 B1 W6 W5 W4 W3 W2 W1 W5 W4 W3W2 W1 T2 0-5-8(0-3-0)1907#/-372#0-5-8(0-3-0)1907#/-372# 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 123x4 3x8 7x8 3x8 5x8 5x8 3x4 10x12 3x4 3x4 5x8 1.5x4 3x4 3x4 5x8 1.5x4 32-0-0 1-4-0 1-4-0 1-9-8 0-5-8 9-4-8 7-7-0 17-4-0 7-11-8 25-3-8 7-11-8 32-10-8 7-7-0 33-4-0 0-5-8 34-8-0 1-4-0 1-9-8 1-9-8 6-2-3 4-4-11 12-2-5 6-0-1 17-4-0 5-1-11 22-5-11 5-1-11 28-5-13 6-0-1 32-10-8 4-4-11 34-8-0 1-9-8 0-6-812-1-30-6-87-10-158.00 12 6.11 12 Plate Offsets (X,Y)-- [3:0-3-12,0-2-0], [5:0-1-12,0-1-8], [6:0-5-12,0-3-4], [7:0-1-12,0-1-8], [9:0-3-12,0-2-0], [14:0-6-0,0-3-15] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.610.580.85 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.49-0.981.14 (loc)1414-1512 l/defl>767>382n/a L/d240180n/a PLATESMT20 Weight: 143 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF 2100F 1.8E *Except* B1: 2x4 SPF No.2WEBS2x4 SPF No.2 *Except* W6: 2x4 SPF 1650F 1.5EBRACING-TOP CHORDStructural wood sheathing directly applied or 2-11-12 oc purlins.BOT CHORDRigid ceiling directly applied or 9-1-5 oc bracing. WEBS 1 Row at midpt 9-12, 3-16 REACTIONS.(lb/size) 16 =1761/0-5-812 =1761/0-5-8Max Horz16 =305(LC 10)Max Uplift16 =-372(LC 11)12 =-372(LC 12)Max Grav16 =1907(LC 2) 12 =1907(LC 2) Max Grav16 =1907(LC 2)12 =1907(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD3-5=-4540/641, 5-6=-4286/410, 6-7=-4286/410, 7-9=-4540/641BOT CHORD15-16=-741/3338, 14-15=-607/4412, 13-14=-354/4412, 12-13=-456/3338 WEBS 6-14=-295/4200, 7-14=-601/447, 7-13=-459/148, 9-13=0/716, 9-12=-4121/657, 10-12=-365/195, 5-14=-601/368, 5-15=-459/38, 3-15=0/716, 3-16=-4121/657, 2-16=-365/197 NOTES-(11)1) This truss has been checked for uniform roof live load only, except as noted.2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B;partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-0-0 to 3-5-10,Interior(1) 3-5-10 to 13-10-6, Exterior(2) 13-10-6 to 17-4-0, Interior(1) 20-9-10 to 31-2-6zone; cantilever left and right exposed ;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15);Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.8) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 16=372, 12=372.9) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 11) All Plates 20 Gauge Unless Noted Job 35121 Truss S4GE Truss Type GABLE Qty 1 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:45:22 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-ffswkTvKtjQCGF09Az?Uu9q1YOLQ8lpz4gde4pyalxR Scale = 1:70.7 T1 T2 B1 B2 B2 B1 W6 W5 W4 W3 W2 W1 W5 W4 W3W2 W1 T2 ST9ST10 ST7 ST8ST6 ST5ST3 ST4ST2ST1 ST9 ST10 ST7 ST8 ST6 ST5 ST3 ST4 ST2 ST1 0-5-8(0-3-0)1907#/-372#0-5-8(0-3-0)1907#/-372# 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 123x4 6x6 7x8 6x6 3x4 10x12 3x4 5x8 3x4 5x8 1x4 1x4 1x4 1x4 5x8 1x4 1x4 1x4 1x4 1x4 1x4 5x8 1x4 1x4 5x8 1x4 5x8 1x4 32-0-0 1-4-0 1-4-0 1-9-8 0-5-8 9-4-8 7-7-0 17-4-0 7-11-8 25-3-8 7-11-8 32-10-8 7-7-0 33-4-0 0-5-8 34-8-0 1-4-0 1-9-8 1-9-8 6-2-3 4-4-11 12-2-5 6-0-1 17-4-0 5-1-11 22-5-11 5-1-11 28-5-13 6-0-1 32-10-8 4-4-11 34-8-0 1-9-8 0-6-812-1-30-6-87-10-158.00 12 6.11 12 Plate Offsets (X,Y)-- [3:0-3-12,0-2-0], [4:0-3-0,Edge], [5:0-1-12,0-1-8], [6:0-5-12,0-3-4], [7:0-1-12,0-1-8], [8:0-3-0,Edge], [9:0-3-12,0-2-0], [13:0-4-0,0-1-8], [14:0-6-0,0-3-15], [15:0-4-0,0-1-8], [17:0-2-0,0-0-8], [20:0-2-0,0-0-8], [26:0-2-0,0-0-8], [34:0-2-0,0-0-8], [37:0-2-0,0-0-8],[43:0-2-0,0-0-8] LOADING (psf) TCLL (roof) Snow (Pf/Pg)TCDLBCLLBCDL 35.0 30.8/40.010.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress Incr Code 2-0-01.151.15YES IRC2009/TPI2007 CSI.TCBCWB (Matrix) 0.610.580.85 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.49-0.981.14 (loc)1414-1512 l/defl>767>382n/a L/d240180n/a PLATESMT20 Weight: 175 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8EBOT CHORD 2x4 SPF 2100F 1.8E *Except* B1: 2x4 SPF No.2WEBS2x4 SPF No.2 *Except* W6: 2x4 SPF 1650F 1.5EOTHERS2x4 SPF StudBRACING-TOP CHORDStructural wood sheathing directly applied or 2-11-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 9-1-5 oc bracing. WEBS 1 Row at midpt 9-12, 3-16 REACTIONS.(lb/size)16 =1761/0-5-812 =1761/0-5-8Max Horz16 =305(LC 10)Max Uplift16 =-372(LC 11)12 =-372(LC 12) Max Grav 16 =1907(LC 2) Max Grav12 =1907(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD3-5=-4540/641, 5-6=-4286/410, 6-7=-4286/410, 7-9=-4540/641BOT CHORD15-16=-741/3338, 14-15=-607/4412, 13-14=-354/4412, 12-13=-456/3338 WEBS 6-14=-295/4200, 7-14=-601/447, 7-13=-459/148, 9-13=0/716, 9-12=-4121/657, 10-12=-365/195, 5-14=-601/368, 5-15=-459/38, 3-15=0/716, 3-16=-4121/657, 2-16=-365/197 NOTES-(14)1) This truss has been checked for uniform roof live load only, except as noted.2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B;partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-0-0 to 3-5-10,Interior(1) 3-5-10 to 13-10-6, Exterior(2) 13-10-6 to 17-4-0, Interior(1) 20-9-10 to 31-2-6zone; cantilever left and right exposed ;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed towind (normal to the face), see Standard Industry Gable End Details as applicable, orconsult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.7) All plates are 1.5x4 MT20 unless otherwise indicated.8) Gable studs spaced at 2-0-0 oc.9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.10) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 16=372, 12=372. 12) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 14) All Plates 20 Gauge Unless Noted Job 35121 Truss S5 Truss Type Roof Special Qty 3 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:41:09 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-Z_3HeyrdT_Y6PMAXrLz98prvzP2OMQwkvprmi_yam?O Scale = 1:31.2 T1 T1 B1 B2 B2 B1 W4 W3 W2 W1 W3 W2 W1 0-5-8(0-1-8) 786#/-185# 0-5-8(0-1-8) 786#/-185# 1 2 3 4 5 6 7 10 9 8 3x4 4x4 3x4 5x5 5x5 5x8 4x4 1x4 4x4 1x4 12-5-8 0-11-0 0-11-0 1-4-8 0-5-8 7-1-12 5-9-4 12-11-0 5-9-4 13-4-8 0-5-8 14-3-8 0-11-0 1-4-8 1-4-8 4-3-2 2-10-10 7-1-12 2-10-10 10-0-6 2-10-10 12-11-0 2-10-10 14-3-8 1-4-8 0-6-85-3-110-6-82-11-48.00 12 6.11 12 Plate Offsets (X,Y)-- [3:0-1-8,0-2-0], [5:0-1-8,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.190.440.49 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.08-0.210.11 (loc)9-109-108 l/defl>999>657n/a L/d240180n/a PLATESMT20 Weight: 57 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2WEBS2x4 SPF StudBRACING-TOP CHORDStructural wood sheathing directly applied or 5-6-9 oc purlins.BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size) 10 =726/0-5-8 8 =726/0-5-8 Max Horz 10 =-129(LC 9) Max Uplift10 =-185(LC 11)8 =-185(LC 12)Max Grav10 =786(LC 2)8 =786(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 3-4=-1106/121, 4-5=-1106/124 TOP CHORD3-4=-1106/121, 4-5=-1106/124BOT CHORD9-10=-232/891, 8-9=-112/891WEBS4-9=-67/903, 5-8=-1181/202, 6-8=-252/133, 3-10=-1181/202, 2-10=-252/135 NOTES-(11) 1) This truss has been checked for uniform roof live load only, except as noted. 2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B; partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 4-1-12, Exterior(2) 4-1-12 to 7-1-12, Interior(1) 10-1-0 to 11-3-8 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.603) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15);Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=185, 8=185. 9) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 11) All Plates 20 Gauge Unless Noted Job 35121 Truss S5B Truss Type Scissor Qty 3 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:42:31 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-9m0Hr?q39AtTFzRIfZROT5EwcS0maU7omai5bDyam_6 Scale = 1:31.6 T1 T1 B1 B1 W4 W3W3 W1 W2 W1 W2 0-5-8(0-1-8) 660#/-131# 0-5-8(0-1-8) 660#/-131# 1 2 3 4 5 8 7 6 2x4 4x4 2x4 5x8 4x4 4x4 3x6 3x6 6-2-12 6-2-12 12-5-8 6-2-12 3-4-2 3-4-2 6-2-12 2-10-10 9-1-6 2-10-10 12-5-8 3-4-2 1-1-135-3-111-1-132-11-48.00 12 6.11 12 Plate Offsets (X,Y)-- [2:0-1-4,0-2-0], [4:0-1-4,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.170.490.56 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.09-0.250.14 (loc)7-87-86 l/defl>999>580n/a L/d240180n/a PLATESMT20 Weight: 54 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2WEBS2x4 SPF Stud *Except* W1: 2x6 SPF No.2BRACING-TOP CHORDStructural wood sheathing directly applied or 5-1-9 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 8 =610/0-5-8 6 =610/0-5-8 Max Horz 8 =104(LC 10)Max Uplift8 =-131(LC 11)6 =-131(LC 12)Max Grav8 =660(LC 2)6 =660(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1258/242, 3-4=-1258/242 TOP CHORD2-3=-1258/242, 3-4=-1258/242BOT CHORD7-8=-307/1082, 6-7=-268/1082WEBS3-7=-182/1081, 2-8=-1350/327, 4-6=-1350/327 NOTES-(12)1) This truss has been checked for uniform roof live load only, except as noted. 2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B; partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15);Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 8, 6 considers parallel to grain value using ANSI/TPI 1 angle tograin formula. Building designer should verify capacity of bearing surface.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 8=131, 6=131. 10) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted Job 35121 Truss S5GE Truss Type GABLE Qty 1 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:41:21 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-CIop93_9eg2PrC5rYsBzdLLyyE8BAruVghlO7Hyam?C Scale = 1:31.2 T1 T1 B1 B2 B2 B1 W4 W3 W2 W1 W3 W2 W1 ST1 ST1 0-5-8(0-1-8) 786#/-185# 0-5-8(0-1-8) 786#/-185# 1 2 3 4 5 6 7 10 9 8 3x4 4x4 3x4 5x5 5x5 5x8 4x4 1x4 4x4 1x4 1x4 1x4 1x4 1x4 12-5-8 0-11-0 0-11-0 1-4-8 0-5-8 7-1-12 5-9-4 12-11-0 5-9-4 13-4-8 0-5-8 14-3-8 0-11-0 1-4-8 1-4-8 4-3-2 2-10-10 7-1-12 2-10-10 10-0-6 2-10-10 12-11-0 2-10-10 14-3-8 1-4-8 0-6-85-3-110-6-82-11-48.00 12 6.11 12 Plate Offsets (X,Y)-- [3:0-1-8,0-2-0], [5:0-1-8,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.190.440.49 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.08-0.210.11 (loc)9-109-108 l/defl>999>657n/a L/d240180n/a PLATESMT20 Weight: 59 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2WEBS2x4 SPF StudOTHERS2x4 SPF StudBRACING-TOP CHORDStructural wood sheathing directly applied or 5-6-9 oc purlins.BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size) 10 =726/0-5-8 8 =726/0-5-8 Max Horz 10 =-129(LC 9)Max Uplift10 =-185(LC 11)8 =-185(LC 12)Max Grav10 =786(LC 2)8 =786(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-1106/121, 4-5=-1106/124 TOP CHORD3-4=-1106/121, 4-5=-1106/124BOT CHORD9-10=-232/891, 8-9=-112/891WEBS4-9=-67/903, 5-8=-1181/202, 6-8=-252/133, 3-10=-1181/202, 2-10=-252/135 NOTES-(13) 1) This truss has been checked for uniform roof live load only, except as noted. 2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B; partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 4-1-12, Exterior(2) 4-1-12 to 7-1-12, Interior(1) 10-1-0 to 11-3-8 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.603) Truss designed for wind loads in the plane of the truss only. For studs exposed towind (normal to the face), see Standard Industry Gable End Details as applicable, orconsult qualified building designer as per ANSI/TPI 1.4) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15);Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.15) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 7) Gable studs spaced at 2-0-0 oc.8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=185, 8=185. 11) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 13) All Plates 20 Gauge Unless Noted Job 35121 Truss T1 Truss Type Common Qty 1 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:27:49 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-_4krkP9psBldRQ0n_KcZj6i2Ewy?welzyL2QdLyamBu Scale = 1:49.5 T1 T1 B1 W4 W3 W4 W3 W2 W1 W2 W1B2 0-5-8(0-2-1) 1311#/-260# 0-5-8(0-2-1) 1311#/-260# 1 2 3 4 5 6 7 12 11 10 9 83x4 4x6 3x4 3x4 3x4 4x4 3x4 4x4 3x4 1.5x4 3x4 1.5x4 22-0-0 0-11-0 0-11-0 7-11-15 7-0-15 15-10-1 7-10-2 22-11-0 7-0-15 23-10-0 0-11-0 5-11-11 5-11-11 11-11-0 5-11-5 17-10-5 5-11-5 23-10-0 5-11-11 0-6-88-5-130-6-88.00 12 Plate Offsets (X,Y)-- [4:0-3-4,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.740.580.37 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.17-0.300.04 (loc)9-119-118 l/defl>999>864n/a L/d240180n/a PLATESMT20 Weight: 106 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2WEBS2x4 SPF Stud *Except* W4: 2x4 SPF No.2BRACING-TOP CHORDStructural wood sheathing directly applied or 3-5-6 oc purlins.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS 1 Row at midpt 3-12, 5-8 REACTIONS.(lb/size) 12 =1211/0-5-8 8 =1211/0-5-8Max Horz12 =-211(LC 9)Max Uplift12 =-260(LC 11)8 =-260(LC 12)Max Grav12 =1311(LC 2)8 =1311(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-3=-335/149, 3-4=-1351/377, 4-5=-1351/377, 5-6=-335/149BOT CHORD11-12=-206/1123, 9-11=-49/797, 8-9=-147/1123WEBS4-9=-133/479, 5-9=-320/220, 4-11=-133/479, 3-11=-320/220, 3-12=-1232/217, 2-12=-355/251, 5-8=-1232/217, 6-8=-355/250 NOTES-(11) 1) This truss has been checked for uniform roof live load only, except as noted. 2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B; partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 8-11-0, Exterior(2) 8-11-0 to 11-11-0, Interior(1) 14-11-0 to 20-10-0zone; cantilever left and right exposed ;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.603) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15);Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 260 lb uplift at joint 12 and 260 lb uplift at joint 8. 9) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 11) All Plates 20 Gauge Unless Noted Job 35121 Truss T1GE Truss Type GABLE Qty 1 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:28:15 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-D4IgBIT7kA1wYQ?nVn4fmbnfIPx?0Q0owOLoXryamBU Scale = 1:49.5 T1 T1 B1 B2 ST6 ST5 ST4 ST3 ST2 ST1 ST5 ST4 ST3 ST2 ST11 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 3x4 4x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 5x5 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 22-0-0 0-11-0 0-11-0 23-10-0 22-11-0 11-11-0 11-11-0 23-10-0 11-11-0 0-6-88-5-130-6-88.00 12 Plate Offsets (X,Y)-- [18:0-2-8,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.120.140.25 DEFL.Vert(LL)Vert(TL)Horz(TL) inn/an/a0.00 (loc)- - 14 l/defln/an/an/a L/d999999n/a PLATESMT20 Weight: 114 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2WEBS2x4 SPF StudOTHERS2x4 SPF StudBRACING-TOP CHORDStructural wood sheathing directly applied or 10-0-0 oc purlins.BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing.WEBS 1 Row at midpt 7-19 REACTIONS.All bearings 22-0-0. (lb) - Max Horz 24=-211(LC 9)Max UpliftAll uplift 100 lb or less at joint(s) 20, 21, 22, 18, 17, 16 except 23=-179(LC 10), 24=-118(LC 9), 15=-170(LC 9), 14=-104(LC 10)Max GravAll reactions 250 lb or less at joint(s) 21, 22, 23, 17, 16, 15 except 19=323(LC 3), 20=301(LC 5), 24=295(LC 15), 18=304(LC6), 14=292(LC 16) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD6-7=-1/309, 7-8=-2/309WEBS7-19=-268/0, 6-20=-255/95, 8-18=-258/95 NOTES-(15)1) This truss has been checked for uniform roof live load only, except as noted.2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B; partially; MWFRS (low-rise) gable end zone and C-C Corner(3) 0-0-0 to 3-0-0, Exterior(2) 3-0-0 to 8-11-0, Corner(3) 8-11-0 to 11-11-0, Exterior(2) 14-11-0 to 20-10-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed towind (normal to the face), see Standard Industry Gable End Details as applicable, orconsult qualified building designer as per ANSI/TPI 1.4) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15);Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.15) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads. 7) All plates are 1x4 MT20 unless otherwise indicated. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.10) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 21, 22, 18, 17, 16 except (jt=lb) 23=179, 24=118, 15=170, 14=104. 12) Non Standard bearing condition. Review required.13) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.14) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 15) All Plates 20 Gauge Unless Noted Job 35121 Truss T2 Truss Type Common Qty 1 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:31:17 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-u5IUOXgHt5y6OOwlA0LK8zKf9mznff7bniRRwIyam8e Scale = 1:43.5 T1 T2 B1 W3 W4 W3W2 W1 W5 W2 0-5-8(0-1-13) 1147#/-249# 937#/-179# 1 2 3 4 5 6 9 8 73x4 4x4 2.5x4 4x4 3x8 4x4 3x4 1.5x4 3x6 1-4-0 1-4-0 1-6-12 0-2-12 10-4-0 8-9-4 19-1-0 8-9-0 5-4-0 5-4-0 10-4-0 5-0-0 15-4-0 5-0-0 19-1-0 3-9-0 0-6-87-5-31-7-38.00 12 Plate Offsets (X,Y)-- [4:0-2-0,0-2-4] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.460.570.57 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.12-0.300.02 (loc)7-87-87 l/defl>999>685n/a L/d240180n/a PLATESMT20 Weight: 83 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2WEBS2x4 SPF Stud *Except* W5: 2x4 SPF No.2BRACING-TOP CHORDStructural wood sheathing directly applied or 5-10-8 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size) 9 =1059/0-5-8 7 =865/Mechanical Max Horz 9 =197(LC 10)Max Uplift9 =-249(LC 11)7 =-179(LC 12)Max Grav9 =1147(LC 2)7 =937(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-851/230, 4-5=-851/230 TOP CHORD3-4=-851/230, 4-5=-851/230BOT CHORD8-9=-179/705, 7-8=-147/727WEBS4-8=-88/368, 3-9=-1025/266, 5-7=-954/228 NOTES-(12)1) This truss has been checked for uniform roof live load only, except as noted. 2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B; partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 7-4-0, Exterior(2) 7-4-0 to 10-4-0, Interior(1) 13-4-0 to 15-11-4 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.603) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15);Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 9=249, 7=179. 10) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) All Plates 20 Gauge Unless Noted Job 35121 Truss T2GE Truss Type GABLE Qty 1 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:31:51 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-ueMKX95ctXEHTcWH99yJW8kYpTfUd51bb?gE7Kyam86 Scale = 1:43.2 T1 T2 B1 W1 ST5 ST4 ST3 ST2 ST1 ST4 ST3 ST2 ST1 1 2 3 4 5 6 7 8 9 10 11 21 20 19 18 17 16 15 14 13 12 3x4 4x4 2.5x4 2.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1-4-0 1-4-0 19-1-0 17-9-0 10-4-0 10-4-0 19-1-0 8-9-0 0-6-87-5-31-7-38.00 12 Plate Offsets (X,Y)-- [1:Edge,0-0-10] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.190.140.28 DEFL.Vert(LL)Vert(TL)Horz(TL) inn/an/a0.00 (loc)- - 12 l/defln/an/an/a L/d999999n/a PLATESMT20 Weight: 90 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2WEBS2x4 SPF Stud *Except* W1: 2x4 SPF No.2OTHERS2x4 SPF StudBRACING-TOP CHORDStructural wood sheathing directly applied or 10-0-0 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 17-9-0. (lb) - Max Horz 21= 197(LC 10) Max UpliftAll uplift 100 lb or less at joint(s) 18, 19, 16, 15, 14 except 12=-301(LC 10), 20=-133(LC 10), 21=-141(LC 11), 13=-336(LC 9)Max GravAll reactions 250 lb or less at joint(s) 19, 20, 15, 14 except12=355(LC 9), 17=317(LC 3), 18=281(LC 5), 21=387(LC 2), 16=297(LC 6), 13=384(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS6-17=-266/0, 2-21=-263/135 NOTES-(15)1) This truss has been checked for uniform roof live load only, except as noted.2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B;partially; MWFRS (low-rise) gable end zone and C-C Corner(3) 0-0-0 to 3-0-0,Exterior(2) 3-0-0 to 7-4-0, Corner(3) 7-4-0 to 10-4-0, Exterior(2) 13-4-0 to 15-11-4 zone;cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15);Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.15) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.7) All plates are 1x4 MT20 unless otherwise indicated.8) Gable studs spaced at 2-0-0 oc.9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 19, 16, 15, 14 except (jt=lb) 12=301, 20=133, 21=141, 13=336. 12) Non Standard bearing condition. Review required. 13) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.14) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 15) All Plates 20 Gauge Unless Noted Job 35121 Truss T4 Truss Type Common Qty 7 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:37:45 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-Xkk9qCNgVJr2x0aKuVJKtnOy_AUFZFAi?4QzYoyam2a Scale = 1:37.8 T1 T2 B1 W3 W1 W2 W5 W4 401#/-61# 0-5-8(0-1-8)401#/-116# 1 2 3 6 5 4 3x4 4x4 1.5x4 1.5x4 3x8 3x4 4-9-0 4-9-0 7-7-0 2-10-0 7-8-8 0-1-8 4-9-0 4-9-0 7-7-0 2-10-0 3-0-16-2-14-3-68.00 12 Plate Offsets (X,Y)-- [1:0-1-12,0-1-8], [3:0-1-12,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.540.150.12 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.02-0.04-0.00 (loc)5-65-64 l/defl>999>999n/a L/d240180n/a PLATESMT20 Weight: 44 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2WEBS2x4 SPF Stud *Except* W1,W5: 2x4 SPF No.2BRACING-TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 6 =370/Mechanical 4 =370/0-5-8 Max Horz 6 =91(LC 10)Max Uplift6 =-61(LC 11)4 =-116(LC 12)Max Grav6 =401(LC 2)4 =401(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-363/93, 3-4=-388/136 TOP CHORD1-6=-363/93, 3-4=-388/136 NOTES-(12)1) This truss has been checked for uniform roof live load only, except as noted.2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B;partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left andright exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6 except (jt=lb) 4=116. 10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) All Plates 20 Gauge Unless Noted Job 35121 Truss T5 Truss Type Common Qty 3 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:38:17 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-bugFY8mkz8tWmx1TmDtqAXjPk3ON3icPM2Afgyyam24 Scale = 1:31.4 T1 T1 B1 W3 W2W1 W2 W1 0-5-8(0-1-8)786#/-182#0-5-8(0-1-8)786#/-182# 1 2 3 4 5 8 7 6 3x4 4x4 3x4 4x9 3x4 1x4 3x4 1x4 12-5-8 0-11-0 0-11-0 7-1-12 6-2-12 13-4-8 6-2-12 14-3-8 0-11-0 7-1-12 7-1-12 14-3-8 7-1-12 0-6-85-3-110-6-88.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-1-8], [4:0-1-12,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.610.230.15 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.02-0.050.01 (loc)7-87-86 l/defl>999>999n/a L/d240180n/a PLATESMT20 Weight: 56 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2WEBS2x4 SPF StudBRACING-TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 8 =726/0-5-8 6 =726/0-5-8 Max Horz 8 =-129(LC 9) Max Uplift8 =-182(LC 11)6 =-182(LC 12)Max Grav8 =786(LC 2)6 =786(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 2-3=-636/137, 3-4=-636/137 TOP CHORD2-3=-636/137, 3-4=-636/137BOT CHORD1-8=-101/272, 7-8=-208/272, 6-7=-103/272, 5-6=-103/272WEBS2-8=-679/256, 4-6=-679/256 NOTES-(11)1) This truss has been checked for uniform roof live load only, except as noted. 2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B; partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 4-1-12, Exterior(2) 4-1-12 to 7-1-12, Interior(1) 10-1-12 to 11-3-8 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.603) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15);Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=182, 6=182. 9) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 11) All Plates 20 Gauge Unless Noted Job 35121 Truss T5B Truss Type Common Qty 1 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:40:06 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-vsmSQP46Idc2LhsQfcKO4WkxY?av6?BSQW4w?7yam0N Scale = 1:31.4 T1 T1 B1 W3 W1 W2 W1 W2 0-5-8(0-1-8)763#/-177#0-5-8(0-1-8)763#/-177# 1 2 3 4 5 8 7 6 4x4 2x4 2x4 4x9 3x6 3x6 6-2-12 6-2-12 12-5-8 6-2-12 -0-11-0 0-11-0 6-2-12 6-2-12 12-5-8 6-2-12 13-4-8 0-11-0 1-1-135-3-111-1-138.00 12 Plate Offsets (X,Y)-- [2:0-2-8,0-1-8], [4:0-2-8,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.980.290.18 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.03-0.090.00 (loc)6-76-76 l/defl>999>999n/a L/d240180n/a PLATESMT20 Weight: 55 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2WEBS2x4 SPF Stud *Except* W1: 2x6 SPF No.2BRACING-TOP CHORDStructural wood sheathing directly applied, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 8 =703/0-5-8 6 =703/0-5-8 Max Horz 8 =-107(LC 9)Max Uplift8 =-177(LC 11)6 =-177(LC 12)Max Grav8 =763(LC 2)6 =763(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-609/132, 3-4=-609/132, 2-8=-717/220, 4-6=-717/220 TOP CHORD2-3=-609/132, 3-4=-609/132, 2-8=-717/220, 4-6=-717/220WEBS2-7=-11/408, 4-7=-11/408 NOTES-(12)1) This truss has been checked for uniform roof live load only, except as noted.2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B;partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 3-2-12, Exterior(2) 3-2-12 to 6-2-12, Interior(1) 9-2-12 to 10-4-8 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.6) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=177, 6=177. 10) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted Job 35121 Truss T5C Truss Type Common Qty 1 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:40:23 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-v8Hu_DHmIrleuIfh9g8NH6xussNubhJyKfiK5eyam06 Scale = 1:31.4 T1 T1 B1 W3 W1 W2 W1 W2 0-5-8(0-1-8)660#/-131#0-5-8(0-1-8)660#/-131# 1 2 3 6 5 4 3x6 4x4 3x6 2x4 2x4 4x9 6-2-12 6-2-12 12-5-8 6-2-12 6-2-12 6-2-12 12-5-8 6-2-12 1-1-135-3-111-1-138.00 12 Plate Offsets (X,Y)-- [1:0-2-8,0-1-8], [3:0-2-8,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDLBCLLBCDL 35.0 30.8/40.0 10.00.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.810.290.18 DEFL.Vert(LL)Vert(TL)Horz(TL) in-0.03-0.09-0.00 (loc)5-64-54 l/defl>999>999n/a L/d240180n/a PLATESMT20 Weight: 53 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2WEBS2x4 SPF Stud *Except* W1: 2x6 SPF No.2BRACING-TOP CHORDStructural wood sheathing directly applied or 3-5-6 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 6 =610/0-5-8 4 =610/0-5-8 Max Horz 6 =104(LC 10)Max Uplift6 =-131(LC 11)4 =-131(LC 12)Max Grav6 =660(LC 2)4 =660(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-618/133, 2-3=-618/133, 1-6=-614/177, 3-4=-614/177 TOP CHORD1-2=-618/133, 2-3=-618/133, 1-6=-614/177, 3-4=-614/177WEBS1-5=-25/420, 3-5=-25/420 NOTES-(11)1) This truss has been checked for uniform roof live load only, except as noted.2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B;partially; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=131, 4=131. 9) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 11) All Plates 20 Gauge Unless Noted Job 35121 Truss T5GE Truss Type GABLE Qty 1 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 12:38:44 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-I5pTCN4gcRHhW4bfsOs9mEL8GydEux_OZlDa6uyam1f Scale = 1:29.0 T1 T1 B1 ST4 ST3 ST2 ST1 ST3 ST2 ST11 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 3x4 4x4 3x4 12-5-8 0-11-0 0-11-0 14-3-8 13-4-8 7-1-12 7-1-12 14-3-8 7-1-12 0-6-85-3-110-6-88.00 12 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLLBCDL 35.0 30.8/40.0 10.0 0.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.080.070.10 DEFL.Vert(LL)Vert(TL)Horz(TL) inn/an/a0.00 (loc)- - 10 l/defln/an/an/a L/d999999n/a PLATESMT20 Weight: 56 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF StudOTHERS2x4 SPF StudBRACING-TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 12-5-8. (lb) - Max Horz 16=-129(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 14, 16, 12, 10 except 15=-122(LC 10), 11=-116(LC 9)Max GravAll reactions 250 lb or less at joint(s) 14, 15, 16, 12, 11, 10 except 13=266(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(15)1) This truss has been checked for uniform roof live load only, except as noted. 2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B;partially; MWFRS (low-rise) gable end zone and C-C Corner(3) 0-0-0 to 3-1-12,Exterior(2) 3-1-12 to 4-1-12, Corner(3) 4-1-12 to 7-1-12, Exterior(2) 10-1-12 to 11-1-12zone; cantilever left and right exposed ;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 PlateDOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.15) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.7) All plates are 1x4 MT20 unless otherwise indicated.8) Gable studs spaced at 2-0-0 oc.9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 11) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) 14, 16, 12, 10 except (jt=lb) 15=122, 11=116.12) Non Standard bearing condition. Review required.13) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 14) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 15) All Plates 20 Gauge Unless Noted Job 35121 Truss TP1 Truss Type Piggyback Qty 13 Ply 1 PEACHTREE [LOT 12 RIDGEVIEW ESTATES] Job Reference (optional)7.640 s Oct 7 2015 MiTek Industries, Inc. Fri Sep 23 09:55:16 2016 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:zf9i1glgZ4SaedAIQqKHUVyd7mW-UBAdjgOSPwZKrooeHXv8Fw72tHBLs5MkDqLasNyaoQv Scale = 1:12.8 T1 T1 B1 W1 1 2 3 4 5 6 4x4 2x4 2x4 1x4 5-7-0 5-7-0 5-7-0 5-7-0 0-4-91-10-50-1-100-4-90-1-108.00 12 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLLBCDL 35.0 30.8/40.0 10.0 0.0 *10.0 SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode 1-4-01.151.15YESIRC2009/TPI2007 CSI.TCBCWB(Matrix) 0.050.020.01 DEFL.Vert(LL)Vert(TL)Horz(TL) in0.000.000.00 (loc)544 l/defln/rn/rn/a L/d12090n/a PLATESMT20 Weight: 13 lb FT = 10% GRIP197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2BRACING- TOP CHORDStructural wood sheathing directly applied or 5-7-0 oc purlins.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2 =106/4-0-6 4 =106/4-0-6 6 =117/4-0-6 Max Horz 2 =25(LC 10) Max Uplift2 =-45(LC 11)4 =-45(LC 12)6 =-10(LC 11)Max Grav2 =116(LC 2)4 =116(LC 2)6 =126(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(14) 1) This truss has been checked for uniform roof live load only, except as noted.2) Wind: ASCE 7-05; 95mph; TCDL=4.2psf; BCDL=5.0psf; h=19ft; Cat. II; Exp B;partially; MWFRS (low-rise) automatic zone and C-C Exterior(2) zone; cantilever left andright exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-05; Pr=35.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=40.0 psf (ground snow); Pf=30.8 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.6) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.7) Gable requires continuous bottom chord bearing. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 45 lb uplift at joint 2, 45 lb uplift at joint 4 and 10 lb uplift at joint 6.11) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 13) See Standard Industry Piggyback Truss Connection Detail for Connection to basetruss as applicable, or consult qualified building designer.14) All Plates 20 Gauge Unless Noted P 12 GENERAL SPECIFICATIONS 1. WITH BASE TRUSSES ERECTED (INSTALLED), APPLY SHEATHING TO TOP CHORD OF SUPPORTING (BASE) TRUSSES. 2. BRACE BOTTOM CHORD AND WEB MEMBERS PER TRUSS DESIGNS. 3. DEFINE VALLEY RIDGE BY RUNNING A LEVEL STRING FROM THE INTERSECTING RIDGE OF THE ( a.) GABLE END, (b.) GIRDER TRUSS OR (c.) COMMON TRUSS TO THE ROOF SHEATHING. 4. INSTALL 2 x 4 VALLEY PLATES. FASTEN TO EACH SUPPORTING TRUSS WITH ( 2 ) 16d (3.5" X .131") NAILS. 5. SET 2 x 6 #2 RIDGE BOARD. SUPPORT WITH 2 x 4 POSTS SPACED 48" O.C.. BEVEL BOTTOM OF POST TO SET EVENLY ON THE SHEATHING. FASTEN POST TO RIDGE WITH ( 4 ) 10d (3" X .131")NAILS. FASTEN POST TO ROOF SHEATHING WITH ( 3 ) 10d (3" X .131")TOE-NAILS. 6. FRAME VALLEY RAFTERS FROM VALLEY PLATE TO RIDGE BOARD. MAXIMUM RAFTER SPACING IS 24" O.C.. FASTEN VALLEY RAFTER TO RIDGE BEAM WITH ( 3 ) 16d (3.5" X .131") TOE-NAILS. FASTEN VALLEY RAFTER TO VALLEY PLATE WITH ( 3 ) 16d (3.5" X .131") TOE-NAILS. 7. SUPPORT THE VALLEY RAFTERS WITH 2 x 4 POSTS 48" O.C ( OR LESS ) ALONG EACH RAFTER. INSTALL POSTS IN A STAGGERED PATTERN AS SHOWN ON PLAN DRAWING. ALLIGN POSTS WITH TRUSSES BELOW. FASTEN VALLEY RAFTER TO POST WITH (4) 10d (3" X .131") NAILS. FASTEN POST THROUGH SHEATHING TO SUPPORTING TRUSS WITH ( 2 ) 16d (3.5" X .131") NAILS. 8. POSTS SHALL BE 2 x 4 #2 OR BETTER SPRUCE PINE FIR, DOUG FIR LARCH OR SOUTHERN YELLOW PINE. POSTS EXCEEDING 75" SHALL BE INCREASED TO 4 x 4 OR BE PRE-ASSEMBLED ( 2 ) PLY 2 x 4's FASTENED TOGETHER WITH 2 ROWS OF 10d NAILS 6" O.C.. RIDGE BOARD ( SEE NOTE #6 ) POST ( SEE NOTE #8 )VALLEY RAFTERS ( SEE NOTE #2) VALLEY PLATE ( SEE NOTE #4 ) TRUSS TYPICAL ( 24" O.C. ) TRUSS MUST BE SHEATHED GABLE END, COMMON TRUSS OR GIRDER TRUSS POST ( SEE NOTE #8 ) LIVE LOAD = 30 PSF (MAX) DEAD LOAD = 15 PSF (MAX) D.O.L. INC = 1.15 ASCE 7-98, ASCE 7-02, ASCE 7-05 90 MPH (MWFRS) GABLE END, COMMON TRUSS OR GIRDER TRUSS NOTE: 48" O.C. MAXIMUM POST SPACING JANUARY 1, 2009 ST-VALLEY1CONVENTIONAL VALLEY FRAMING DETAIL PLAN DRAWING PLAN SECTION MiTek Industries, Inc. R