25A-029 11 Marshall St Northampton unit 2 final air leakage reportAir Leakage Property Sheila Moos 11 Marshall St, Unit 2 Northampton, MA 01060 Weather:Chicopee, MA 11 Marshall St, Unit 2 P15980 11 Marshall St Northampton Unit 2-final.blg Organization Center for EcoTechnology 413-586-7350 John Saveson Builder Sheila Moos Whole House Infiltration ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole-building' requirement under that version of the standard. The 62.2-2013 rate incorporates any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Confirmed 2018-07-13 Rating No:P15980 Rater ID:1911963 Duct Leakage Ventilation Blower Door Test Heating Cooling Natural ACH 0.14 0.11 ACH @ 50 Pascals 3.00 3.00 CFM @ 25 Pascals 200 200 CFM @ 50 Pascals 314 314 Eff. Leakage Area (sq.in) 17.2 17.2 Specific Leakage Area 0.00014 0.00014 ELA/100 sf shell (sq.in) 0.67 0.67 CFM50/sf shell 0.12 0.12 Leakage to Outside Units minisplit CFM @ 25 Pascals 0 CFM25 / CFMfan 0.0000 CFM25 / CFA 0.0000 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 0 Eff. Leakage Area (sq.in) 0.00 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.0000 Mechanical Exhaust Only ASHRAE ASHRAE Sensible Recovery Eff. (%) 0.0 62.2-2010 62.2-2013 Total Recovery Eff. (%) 0.0 Rate (cfm)40 31 41 Hours/Day 24.0 24.0 24.0 Fan Watts 5.7 Cooling Ventilation Natural Ventilation