Loading...
32C-120 Existing Conditions Report _11Conz Existing Conditions Evaluation Report Massachusetts Building Code 780 CMR 8th Edition & International Existing Building Code 2009 Exterior Stair Replacement and Porch Modification 11 Conz Street Northampton, Massachusetts 01060 October 31, 2013 As prepared by Richard E. Katsanos, AIA, Principal H|AI Architecture Massachusetts Building Code 780 CMR 8th Edition International Existing Building Code 2009 Exterior Stair Replacement and Porch Modifications 11 Conz Street Northampton, Massachusetts 01060 Purpose This Report is in conformance with Massachusetts Building Code 780 CMR 8th Edition and the International Existing Building Code 2009 regarding alterations to an existing building located at 11 Conz Street, Northampton, Massachusetts. Visual Observation Only The extent of this review is limited to visual inspection of existing facilities and/or as-built documentation only. No destructive testing was performed as part of this analysis. Project Description The project consists of the removal of portions of a deteriorated porch, patching and repairing of the existing building where the removal of the porch exposes unfinished surfaces, repair and stabilization of portions of the porch to remain, and replacement of an exterior stair leading from the second floor to grade (existing stair is a previous non-compliant repair) The repaired portion of the porch shall use materials in keeping with the existing construction. The replacement stair will be constructed of code compliant pressure treated lumber in a configuration meeting applicable commercial building code &80 CMR 8th Edition. GENERAL EXISTING PROPERTY INFORMATION A. PROPERTY NAME: -- B. ADDRESS: 11 Conz Street, Northampton, MA 01060 C. BUILDING USE: The building was originally constructed as a single family home but has been converted to a multi-tenant occupancy, and is currently categorized as R2 (Residential) occupancy. D. BUILDING USE GROUP: R2- Residential) as defined by the Massachusetts Building Code, 780 CMR 8th Edition. E. CONSTRUCTION CLASSIFICATION: Type 5B Foundation: concrete slab; brick foundation walls Exterior Walls: wood frame/ wood sheathing/ vinyl siding Int. Load Bearing: wood framed partitions Roof: wood framed with asphalt shingles F. HAZARD INDEX: Existing and proposed Hazard Index is 3 as defined by the Massachusetts Building Code, 780 CMR, 8th Edition (IEBC Table 912.4) CLASSIFICATION OF WORK The proposed project work area is classified as Alteration - Level 1 per IEBC Section 404 and therefore complies with the provisions of Chapter 6 and Chapter 7 for the following reasons: - While the porch demolition and repair portion of the project is a repair, the overall project is not a repair, therefore IEBC Section 402 does not apply - The project meets the limitations defined under Level 1 Alterations as specified in IEBC Section 403: Level 1 alterations include the removal and replacement or the covering of existing materials, elements, equipment, or fixtures using new materials, elements, equipment, or fixtures that serve the same purpose. - The project is below the limitations defined under Level 2 Alterations as specified in IEBC Section 404: Level 2 alterations include the reconfiguration of space, the addition or elimination of any door or window, the reconfiguration or extension of any system, or the installation of any additional equipment. - The project is below the threshold triggering Level 3 Alterations as specified in IEBC Section 404: Level 3 alterations apply where the work area exceeds 50 percent of the aggregate area of the building. - The project does not involve a change of occupancy, therefore IEBC Section 406 does not apply. - The project does not involve an addition, therefore IEBC Section 407 does not apply. - The project does not involve a historic building, therefore IEBC Section 408 does not apply. - The project does not involve a relocated building, therefore IEBC Section 409 does not apply. ALTERATIONS LEVEL 1 Section 601 General This project work area will comply with all requirements for Alteration Level 1 as specified in Chapter 6. No portion of the proposed project work area alters the existing conditions such that the building will become less safe than its existing condition. Requirements regarding flood hazard areas are not applicable to this project Section 602 Building Elements and Materials 602.1 Interior finishes n/a 602.2 Interior floor finish n/a 602.3 Interior trim n/a 602.4 Materials and methods All new work shall comply with materials and methods requirements in the International Building Code regarding material standards, detail of installation and connection, joints, penetrations, and continuity of any element, component, or system in the building. Section 603 Fire Protection n/a Section 604 Means of Egress The existing and new egress requirements within the project work area are compliant with Massachusetts Building Code 780 CMR 8th Edition. Handrails The new exit stair shall have compliant handrails. Guards The new exit stair shall have compliant guards. Section 605 Accessibility The dimensions of the new exit stair shall comply to requirements of 780 CMR 8th Edition and current Architectural Access Barriers Code regarding tread depth and riser height, as well as handrail requirements. Section 606 Structural n/a. This section refers to alteration work which includes replacement of equipment that is supported by the building or where a reroofing permit is required. Section 607 Energy Conservation n/a END OF EXISTING CONDITIONS REVIEW REPORT