Loading...
32A-154 digitalplans68strongave_ 6 Strong Ave Overview.pdf6 Strong Ave Overview 6 Strong Avenue—Overview Zone 1— Dining Car • Walls: Tongue and Groove Oak Panels • Floors: 3/4” Dark Walnut • Ceiling: 1/2” Sheet Rock (coated with 1hr Fire Protective Paint) Zone 2 — Kitchen • Walls: 5/8” Drywall w/ FRP Panels • Floors: Poured Concrete w/ Epoxy Finish • Ceiling: 5/8” Sheet Rock Zones 3, 4, 5 — Service Counter/Back Room • Walls: Tongue and Groove Oak Panels • Floors: 3/4” Dark Walnut in Zone 4, 1/4” Vinyl in Zones 3+5 (made level with 1/2” plywood) • Ceiling: Oak Beams and 5/8” Sheet Rock Zones 6, 7 — Customer Bathrooms • Walls: Tongue and Groove Oak Panels, 5/8” Mold Resistant Sheet Rock • Floors: 1/4” Vinyl (made level with 1/2” plywood) with 1/8” Thermoplastic Rubber Wall Cove Base between floor and wall • Ceiling: 5/8” Sheet Rock Zone 8 — Prep Area • Walls: 1/2” Sheet Rock (coated with 1hr Fire Protective Paint) with FRP Panels* • Floors: Poured Concrete w/ Epoxy Finish • Ceiling: 5/8” Sheet Rock Zone 9 — Break Room/Employee Bathroom • Walls: 5/8” Mold Resistant Sheet Rock • Floors: Poured Concrete with Epoxy Finish • Ceiling: 5/8” Sheet Rock Zone 10 — Office • Walls: 1/2” Sheet Rock (coated with 1hr Fire Protective Paint) • Floors: Poured Concrete with Epoxy Finish • Ceiling: 5/8” Sheet Rock Proposed Deck and Access Ramp • Flooring of patio: 3’x3’ stone pavers • Ramp Floor: 2x6 Composite Lumber • Posts: 4x4 Pressure Treated Lumber with Simpson Strong-Tie base • Framing: 2x6 Pressure Treated Lumber • Rails: Steel (and compliant with 521 CMR 24.5) Familiars Final Drawing.pdfC:\Users\russels\Documents\familiars plans.pdf 57' - 7 1/8" 19' - 7" 14' - 7 1/2" 3' - 4" 5' - 9" 5' - 3" 21' - 1" 2' - 8 1/2"15' - 8"2' - 8 1/2" 3' - 0" 2' - 6" POS H20 61 SF Emp. Area 3 116 SF Emp. Area 5 5' - 11"21' - 8 5/16" 183 SF Seating Area 4 8' - 3 1/4" 7' - 4 1/2" 0' - 5 1/8" 3' - 9"11' - 6 3/16"3' - 6" EGG STEAMER 193/4" X 17 1/2" FOOD STORAGE 3317/32"X 641/8" TOASTER OVEN DD FRIDGE 29 1/2" X 54 1/8" HAND SINK 15" X 17" DW 3 BASIN SINK 224 SF Kitchen 2 13' - 1 3/4" 7' - 11 3/4" 7' - 2 1/4" 16' - 11 3/4" 12' - 10" BAR SEATING BAR SEATING CONDIMENT BAR BENCH SEATING 3' - 2" 4' - 2 1/2" 9' - 1 1/2" 4' - 2" BENCH SEATING 7' - 0"10' - 0"5' - 0" 5' - 0" 20' - 0" LEVEL LANDING PITCH DN 1:12 LEVEL LANDING PITCH DN 1:12 LANDING 1:50 STAIR MAX RISER 7" PROPOSED PATIO AND RAMP HANDRAILS @ 18" AND 36" BOTH SIDES 503 SF Dining Car 1 12' - 0 1/2"13' - 6" 7' - 10" 42 SF WC 1 6 42 SF WC 2 7 DN EXISTING DOORS TO BE SEALED NO ACCESS A102 1 22' - 0" 25' - 8" 0' - 8" PROPOSED PATIO AND RAMP -2'-7" TERRACE 4' - 5" 2' - 6" 2' - 6" 1' - 8" 4'x4' TYPE 2 HOOD ABOVE EXISTING SERVICE / DELIVERY RAMP (NO PUBLIC ACCESS) 1' - 6" EXISTING RETAINING WALL 0' - 5 1/4" 20' - 7" 12' - 7" 13' - 6" 13' - 6" 19' - 0" 8' - 6" 5' - 0" 5' - 0" 5' - 6" 238 SF Office 10 267 SF Break Room 9 241 SF Prep Area 8 18' - 6 1/2" UP ICE MACHINE HAND SINK UTILITY SINK THE ORIGINAL OF THIS DRAWING IS 24" X 36". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY. KEY PLAN OWNER PROJECT DRAWING TITLE SCALEDATE JOB NUMBER DRAWING NUMBER P R O G R E S S P R I N T SUBMISSION STEPHEN C M RUSSELL ARCHITECTURAL DESIGNER 1/4" = 1'-0" 11/15/2017 6:34:30 PM C:\Users\russels\De sktop\Familiars\familiars plans.rvt 1 1 / 1 5 / 2 0 1 7 6 : 3 4 : 3 0 P M 0001 A101 10/23/17 Floor Plans Familiars Coffee & Tea DANIEL McCOLGAN & ISSAC WEINER UNDER THE LEASE OF GARY PERMAN Familiars Coffee & Tea 6 Strong Ave Northampton, MA 01060 1/4" = 1'-0" 1 Level 1 - Floor Plan 1/4" = 1'-0" 2 Basement - Floor Plan NOTE: STEPHEN CM RUSSELL HAS DRAFTED THESE PLANS FOR THE USE OF JAMES FLANNERY CONSTRUCTION. STEPHEN CM RUSSELL IS NOT RESPONSIBLE FOR ANY ERRORS AND OMISSIONS ON THESE PLANS AND ASSUMES NO LIABILITY FOR THE USE OF THESE PLANS. NO.DATEDESCRIPTION 7' - 7" 4' - 8" 2' - 11" 5' - 4"5' - 6" 0' - 5" 1' - 5" 1' - 6" 1' - 6" 1' - 6" 3' - 0"3' - 0" ø 5 ' 0 " ø 5 ' 0 " 4' - 8" 0' - 0" 0' - 0" 1' - 6" 1' - 6" THE ORIGINAL OF THIS DRAWING IS 24" X 36". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED. TAKE APPROPRIATE PRECAUTIONS ACCORDINGLY. KEY PLAN OWNER PROJECT DRAWING TITLE SCALEDATE JOB NUMBER DRAWING NUMBER P R O G R E S S P R I N T SUBMISSION STEPHEN C M RUSSELL ARCHITECTURAL DESIGNER 1/2" = 1'-0" 11/15/2017 6:34:30 PM C:\Users\russels\Desktop\Familiars\familiars plans.rvt 1 1 / 1 5 / 2 0 1 7 6 : 3 4 : 3 0 P M 0001 A102 11/06/17 Enlarged Bathroom Plan Familiars Coffee & Tea DANIEL McCOLGAN & ISSAC WEINER UNDER THE LEASE OF GARY PERMAN Familiars Coffee & Tea 6 Strong Ave Northampton, MA 01060 NO.DATEDESCRIPTION NOTE: STEPHEN CM RUSSELL HAS DRAFTED THESE PLANS FOR THE USE OF JAMES FLANNERY CONSTRUCTION. STEPHEN CM RUSSELL IS NOT RESPONSIBLE FOR ANY ERRORS AND OMISSIONS ON THESE PLANS AND ASSUMES NO LIABILITY FOR THE USE OF THESE PLANS. 1/2" = 1'-0" 1 Enlarged Bathroom Plan Familiars Coffe n Tea.pdfZ:\Mike G Tranfer Recents may 16\US Imperial\Kathys Diner.pdf Scale Project number Date Drawn by Checked by 21 west st. - west hatfield, ma. - 01088 413.247.8300 12/29/2017 1:24:41 PM A1 Elevations Project Number 6 Strong Ave. N'Hampton Familiars Coffee & Tea Issue Date Author Checker No.DescriptionDate 1{3D} 23D View 3 33D View 4 43D View 2 ADA Access Overview.pdfADA Access Overview 6 Strong Ave—ADA Compliance Overview Public Bathrooms • Both public bathrooms include 5’ (60”) wheelchair turning space • in accordance with the United States Access Board DOJ’s 2010 ADA Standards, Chapter 3 (304.3.1), “Circular Space. The turning space shall be a space of 60” diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306”. • Bathroom layouts ensure minimum clear floor space (30”x48”) in front of all fixtures • in accordance with 521 CMR 6.4.1, “clear floor or ground space for wheelchairs may be part of the knee space required under objects”. • Toilets (water closets) will be installed according to requirements laid out in 521 CMR 30.7 “Water Closets” • Location: The centerline of the water closet shall be located 18” from the nearest side wall and at least 42” from the farthest side wall or the closest edge of an adjacent fixture. • Height: Water closets shall be 17” to 19” high, measured to the top of the water closet seat. • Toilet Paper Dispensers: Toilet paper dispensers shall be located on the side wall closest to the water closet. The centerline of the roll shall be set at a minimum height of 24” above the floor. • Grab bars will be installed as outlined in 521 CMR 30.8 • Sink shall be installed according to requirements laid out in 521 CMR 30.9. • No more than 12” of wheelchair turning space within bathroom will extend under the sink, allowing for knee and toe clearance underneath fixture while maintaining minimum of 48” clear floor space in front of fixtures. Clear floor space, wheelchair turning space, and knee clearance may overlap as outlined in 521 CMR 6.4.1 and United States Access Board DOJ’s 2010 ADA Standards, Chapter 3 (304.3.1) Access Ramp and Entrances/Doors • Both original front doors are to be sealed, thereby moving the main and only public entrance of the building to the side door on the proposed new deck. • The main entrance will be accessible via the proposed ramp included in the plan for the deck. The ramp length will total 30 feet to account for the 30 inch rise to the main entrance. • This ramp, in accordance with 521 CMR 24.2, will be pitched at a slope of 1:12. • The ramp will contain two ramp runs at 20 feet and 10 feet respectively, both 48 inches wide in compliance with 521 CMR 24.3. • The 5x5 foot landing required at the start of the ramp will partially include the public sidewalk. • The ramp will change direction after the first 20 feet at a 5x5 feet level landing in compliance with 521 CMR 24.4 • The 10 foot run will terminate at a 7x7 foot level landing and main entrance of the building in compliance with both 521 CMR 24.3 for ramp width and 521 CMR 26.6.3, fig. 26d for maneuvering clearance. • The ramp will include handrails installed in compliance with 521 CMR 24.00 • The proposed door will be made installed in compliance with 521 CMR 26.5 for minimum width, and swing out in the direction of egress while allowing for 48 inch accessible route from ramp should the door be open in full swing, and including the required 18 inches parallel to the latch side of the door for a forward, pull approach. Accessible Seating • No less than two accessible tables will be provided on accessible routes and in compliance with 521 CMR 17.2 • Tables will meet minimum requirements for table height as outlined in 521 CMR 17.2.5, include required minimum knee clearances, clear floor space, and access aisles as outlined in 521 CMR 17.2.2-17.2.4 • Total number of accessible tables determined in compliance with 521 CMR 17.2— at least 5% but not less than one of total tables provided. Total occupancy, and thereby number of tables, determined in compliance with Table 1004.1.1 in the 2009 International Building Code, Chapter 10, page 220. Accessible Routes • All public areas of the space will be laid out to incorporate accessible routes in compliance with 521 CMR 20. Counter Height and Reach Ranges • The cash register and food/beverage hand-off surfaces shall comply with 521 CMR 7.2.1 and 521 CMR 17.10 • Neither counter will exceed the maximum height of 36 inches, and both counters will be located on an accessible route of no less than 36 inches as shown in Fig. 17e • The food/beverage hand-off counter will also serve as an accessible tableware and condiment area as outlined in 521 CMR 17.7, with the maximum required reach never exceeding 10 horizontal inches onto the counter.