Loading...
24C-197 HVAC 2Load Short Form Job: 14B WrightSoft Date: Jan 12, 2015 Entire House By: RON G PIOTTE'S PLUMBING Project Inf• • For: "CUSTOM RESIDENCE" - ADARE PL - Z2 ADARE PL, NORTHAMPTON, MA HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE 0 MBtuh Design Information Btuh Htg Clg Infiltration Outside db (°F) 0 88 Method Simplified Inside db (°F) 70 75 Construction quality Tight Design TD (°F) 70 13 Fireplaces 0 Daily range - M Inside humidity (%) 50 50 Moisture difference (gr/Ib) 51 22 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE 0 MBtuh 0 Btuh 0 OF 1055 cfm 0 cfm/Btuh 0.10 in H2O COOLING EQUIPMENT Make NORDYNE Area (ft2) Trade FRIGIDAIRE FS4BE SERIES Clg load (Btuh) Cond FS4BE-030KA Clg AVF (cfm) Coil ADP BCRMB6636S3N3 312 AHRI ref 5534930 5113 Efficiency 12.2 EER, 14 SEER 246 Sensible cooling 21140 Btuh Latent cooling 9060 Btuh Total cooling 30200 Btuh Actual air flow 1055 cfm Air flow factor 0.048 cfm/Btuh Static pressure 0.10 in H2O Load sensible heat ratio 0.91 121 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MASTER BED/CLOS 312 0 5113 0 246 MASTER BATH 95 0 1785 0 86 BATH 2 48 0 994 0 48 BED ROOM 2 121 0 2070 0 100 BED ROOM 3 120 0 2693 0 130 LAUNDRY/HALL 132 0 15 0 1 BED ROOM 4 154 0 3361 0 162 STUDY 121 0 2850 0 137 i nn n rl 4AA. vrr�i� 11/'lLL Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015 -Jan -15 14:38:05 r� WrightSOft' Right -Suite® Universal 2012 12.1.01 RSU13148 Page 1 ACCA, ... Settings\Ron Gagne\My Documents\Wrightsoft HVAC\PIOPLU14B.rup Calc = MA Front Door faces: Page 1