30 Ford Crossing - Manual J&DCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Mar-08 16:11:18 Comfort Builder by Wrightsoft 15.0.19 RSU02778 Page 1 ...uilders\Feinland New Home\Feinland Load Cal.rup Calc = MJ8 Front Door faces: N Job:Load Short Form Mar 08, 2016Date:Entire House Nathan LeMayBy: A Plus HVAC Inc. 26 Airport Drive, Westfield, MA 01085 Phone: (413) 562-0054 Fax: (413) 562-0064 Email: nathan@aplushvacinc.com Web: www.aplushvacinc.com License: 103 Project Information Mark Ledwell, Wright BuildersFor: 48 Bates Street, Northampton, MA 01060 Phone: (413) 586-8287 Design Information InfiltrationClgHtg SimplifiedMethod888Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1362Design TD (°F) M-Daily range 5050Inside humidity (%) 2748Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Trade Carrier WeatherMaker 8000VS Trade Model 58CTA070-16 Cond AHRI ref 2000848 Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input Btuh66000 Sensible cooling Btuh0 Heating output Btuh53000 Latent cooling Btuh0 Low output baseboard Btuh/ft500 Total cooling Btuh0 Total low baseboard ft80 Actual air flow cfm1122 High output baseboard Btuh/ft700 Air flow factor cfm/Btuh0.041 Total high baseboard ft57 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.88 ROOM NAME Area Htg load Clg load Baseboard (ft)Clg AVF (ft²)(Btuh)(Btuh)Low High (cfm) Zone 1 p 1066 14488 14398 29 21 588 (Rest of House)p 1066 9227 515 18 13 21 Zone 2 p 1066 16358 16675 33 23 681 Entire House d 3198 40072 27379 80 57 1122 Other equip loads 0 0 Equip. @ 0.93 RSM 25572 Latent cooling 3679 TOTALS 3198 40072 29252 80 57 1122 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Mar-08 16:11:18 Comfort Builder by Wrightsoft 15.0.19 RSU02778 Page 2 ...uilders\Feinland New Home\Feinland Load Cal.rup Calc = MJ8 Front Door faces: N Job:Load Short Form Mar 08, 2016Date:(Rest of House)Nathan LeMayBy: A Plus HVAC Inc. 26 Airport Drive, Westfield, MA 01085 Phone: (413) 562-0054 Fax: (413) 562-0064 Email: nathan@aplushvacinc.com Web: www.aplushvacinc.com License: 103 Project Information Mark Ledwell, Wright BuildersFor: 48 Bates Street, Northampton, MA 01060 Phone: (413) 586-8287 Design Information InfiltrationClgHtg SimplifiedMethod888Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1362Design TD (°F) M-Daily range 5050Inside humidity (%) 2748Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling Btuh0 Heating output Btuh0 Latent cooling Btuh0 Low output baseboard Btuh/ft500 Total cooling Btuh0 Total low baseboard ft0 Actual air flow cfm0 High output baseboard Btuh/ft700 Air flow factor cfm/Btuh0 Total high baseboard ft0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Baseboard (ft)Clg AVF (ft²)(Btuh)(Btuh)Low High (cfm) Room1 1066 9227 515 18 13 21 (Rest of House)p 1066 9227 515 18 13 21 Other equip loads 0 0 Equip. @ 0.93 RSM 481 Latent cooling 582 TOTALS 1066 9227 1063 18 13 21 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Mar-08 16:11:18 Comfort Builder by Wrightsoft 15.0.19 RSU02778 Page 3 ...uilders\Feinland New Home\Feinland Load Cal.rup Calc = MJ8 Front Door faces: N Job:Load Short Form Mar 08, 2016Date:Zone 1 Nathan LeMayBy: A Plus HVAC Inc. 26 Airport Drive, Westfield, MA 01085 Phone: (413) 562-0054 Fax: (413) 562-0064 Email: nathan@aplushvacinc.com Web: www.aplushvacinc.com License: 103 Project Information Mark Ledwell, Wright BuildersFor: 48 Bates Street, Northampton, MA 01060 Phone: (413) 586-8287 Design Information InfiltrationClgHtg SimplifiedMethod888Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1362Design TD (°F) M-Daily range 5050Inside humidity (%) 2748Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling Btuh0 Heating output Btuh0 Latent cooling Btuh0 Low output baseboard Btuh/ft500 Total cooling Btuh0 Total low baseboard ft0 Actual air flow cfm0 High output baseboard Btuh/ft700 Air flow factor cfm/Btuh0 Total high baseboard ft0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Baseboard (ft)Clg AVF (ft²)(Btuh)(Btuh)Low High (cfm) Living / Kitchen 544 7745 10209 15 11 417 Bedroom 5 206 3066 2714 6 4 111 Bath 1 77 0 0 0 0 0 Foyer 239 3677 1476 7 5 60 Zone 1 p 1066 14488 14398 29 21 588 Other equip loads 0 0 Equip. @ 0.93 RSM 13448 Latent cooling 1148 TOTALS 1066 14488 14596 29 21 588 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Mar-08 16:11:18 Comfort Builder by Wrightsoft 15.0.19 RSU02778 Page 4 ...uilders\Feinland New Home\Feinland Load Cal.rup Calc = MJ8 Front Door faces: N Job:Load Short Form Mar 08, 2016Date:Zone 2 Nathan LeMayBy: A Plus HVAC Inc. 26 Airport Drive, Westfield, MA 01085 Phone: (413) 562-0054 Fax: (413) 562-0064 Email: nathan@aplushvacinc.com Web: www.aplushvacinc.com License: 103 Project Information Mark Ledwell, Wright BuildersFor: 48 Bates Street, Northampton, MA 01060 Phone: (413) 586-8287 Design Information InfiltrationClgHtg SimplifiedMethod888Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1362Design TD (°F) M-Daily range 5050Inside humidity (%) 2748Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling Btuh0 Heating output Btuh0 Latent cooling Btuh0 Low output baseboard Btuh/ft500 Total cooling Btuh0 Total low baseboard ft0 Actual air flow cfm0 High output baseboard Btuh/ft700 Air flow factor cfm/Btuh0 Total high baseboard ft0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Baseboard (ft)Clg AVF (ft²)(Btuh)(Btuh)Low High (cfm) Master Bedroom 308 5164 4542 10 7 185 Hallway 186 0 0 0 0 0 Master Bath 76 1692 1017 3 2 42 Bath 2 52 578 390 1 1 16 Bedroom 2 150 3404 3916 7 5 160 Bedroom 3 150 2362 3201 5 3 131 Bedroom 4 144 3158 3608 6 5 147 Zone 2 p 1066 16358 16675 33 23 681 Other equip loads 0 0 Equip. @ 0.93 RSM 15574 Latent cooling 1948 TOTALS 1066 16358 17523 33 23 681 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Mar-08 16:11:18Comfort Builder by Wrightsoft 15.0.19 RSU02778 Page 1 ...uilders\Feinland New Home\Feinland Load Cal.rup Calc = MJ8 Front Door faces: N Job:Project Summary Mar 08, 2016Date:Entire House Nathan LeMayBy: A Plus HVAC Inc. 26 Airport Drive, Westfield, MA 01085 Phone: (413) 562-0054 Fax: (413) 562-0064 Email: nathan@aplushvacinc.com Web: www.aplushvacinc.com License: 103 Project Information Mark Ledwell, Wright BuildersFor:48 Bates Street, Northampton, MA 01060Phone: (413) 586-8287 Notes: Design Information Hartford Bradley Intl AP, CT, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F8 Outside db °F88Inside db °F70 Inside db °F75Design TD °F62 Design TD °F13Daily range MRelative humidity %50Moisture difference gr/lb27 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh28154 Structure Btuh17781DuctsBtuh11918DuctsBtuh9598Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0HumidificationBtuh0BlowerBtuh0PipingBtuh0Equipment load Btuh40072 Use manufacturer's data nRate/swing multiplier 0.93InfiltrationEquipment sensible load Btuh25572 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Average0Fireplaces Structure Btuh2298DuctsBtuh1381 CoolingHeating Central vent (0 cfm)Btuh031983198Area (ft²)Equipment latent load Btuh36791918819188Volume (ft³)Air changes/hour 0.190.37 Equipment total load Btuh29252Equiv. AVF (cfm)61118 Req. total capacity at 0.70 SHR ton3.0 Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Trade Carrier WeatherMaker 8000VS TradeModel58CTA070-16 CondAHRI ref 2000848 CoilAHRI refEfficiency80 AFUE Efficiency 0 SEERHeating input Btuh66000 Sensible cooling Btuh0Heating output Btuh53000 Latent cooling Btuh0Low output baseboard Btuh/ft500 Total cooling Btuh0Total low baseboard ft80 Actual air flow cfm1122High output baseboard Btuh/ft700 Air flow factor cfm/Btuh0.041Total high baseboard ft57 Static pressure in H2O0Space thermostat Load sensible heat ratio 0.88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Mar-08 16:11:18Comfort Builder by Wrightsoft 15.0.19 RSU02778 Page 2 ...uilders\Feinland New Home\Feinland Load Cal.rup Calc = MJ8 Front Door faces: N Job:Project Summary Mar 08, 2016Date:(Rest of House)Nathan LeMayBy: A Plus HVAC Inc. 26 Airport Drive, Westfield, MA 01085 Phone: (413) 562-0054 Fax: (413) 562-0064 Email: nathan@aplushvacinc.com Web: www.aplushvacinc.com License: 103 Project Information Mark Ledwell, Wright BuildersFor:48 Bates Street, Northampton, MA 01060Phone: (413) 586-8287 Notes: Design Information Hartford Bradley Intl AP, CT, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F8 Outside db °F88Inside db °F70 Inside db °F75Design TD °F62 Design TD °F13Daily range MRelative humidity %50Moisture difference gr/lb27 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh6483 Structure Btuh334DuctsBtuh2744DuctsBtuh181Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0HumidificationBtuh0BlowerBtuh0PipingBtuh0Equipment load Btuh9227 Use manufacturer's data nRate/swing multiplier 0.93InfiltrationEquipment sensible load Btuh481 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Average0Fireplaces Structure Btuh122DuctsBtuh460 CoolingHeating Central vent (0 cfm)Btuh010661066Area (ft²)Equipment latent load Btuh58221322132Volume (ft³)Air changes/hour 0.190.37 Equipment total load Btuh1063Equiv. AVF (cfm)713 Req. total capacity at 0.70 SHR ton0.1 Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/aModeln/a Cond n/aAHRI ref n/a Coil n/aAHRI ref n/aEfficiencyn/a Efficiency n/aHeating input Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0Low output baseboard Btuh/ft500 Total cooling Btuh0Total low baseboard ft0 Actual air flow cfm0High output baseboard Btuh/ft700 Air flow factor cfm/Btuh0Total high baseboard ft0 Static pressure in H2O0Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Mar-08 16:11:18Comfort Builder by Wrightsoft 15.0.19 RSU02778 Page 3 ...uilders\Feinland New Home\Feinland Load Cal.rup Calc = MJ8 Front Door faces: N Job:Project Summary Mar 08, 2016Date:Zone 1 Nathan LeMayBy: A Plus HVAC Inc. 26 Airport Drive, Westfield, MA 01085 Phone: (413) 562-0054 Fax: (413) 562-0064 Email: nathan@aplushvacinc.com Web: www.aplushvacinc.com License: 103 Project Information Mark Ledwell, Wright BuildersFor:48 Bates Street, Northampton, MA 01060Phone: (413) 586-8287 Notes: Design Information Hartford Bradley Intl AP, CT, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F8 Outside db °F88Inside db °F70 Inside db °F75Design TD °F62 Design TD °F13Daily range MRelative humidity %50Moisture difference gr/lb27 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh10179 Structure Btuh9350DuctsBtuh4309DuctsBtuh5048Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0HumidificationBtuh0BlowerBtuh0PipingBtuh0Equipment load Btuh14488 Use manufacturer's data nRate/swing multiplier 0.93InfiltrationEquipment sensible load Btuh13448 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Average0Fireplaces Structure Btuh688DuctsBtuh460 CoolingHeating Central vent (0 cfm)Btuh010661066Area (ft²)Equipment latent load Btuh114885288528Volume (ft³)Air changes/hour 0.190.37 Equipment total load Btuh14596Equiv. AVF (cfm)2753 Req. total capacity at 0.70 SHR ton1.6 Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/aModeln/a Cond n/aAHRI ref n/a Coil n/aAHRI ref n/aEfficiencyn/a Efficiency n/aHeating input Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0Low output baseboard Btuh/ft500 Total cooling Btuh0Total low baseboard ft0 Actual air flow cfm0High output baseboard Btuh/ft700 Air flow factor cfm/Btuh0Total high baseboard ft0 Static pressure in H2O0Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Mar-08 16:11:18Comfort Builder by Wrightsoft 15.0.19 RSU02778 Page 4 ...uilders\Feinland New Home\Feinland Load Cal.rup Calc = MJ8 Front Door faces: N Job:Project Summary Mar 08, 2016Date:Zone 2 Nathan LeMayBy: A Plus HVAC Inc. 26 Airport Drive, Westfield, MA 01085 Phone: (413) 562-0054 Fax: (413) 562-0064 Email: nathan@aplushvacinc.com Web: www.aplushvacinc.com License: 103 Project Information Mark Ledwell, Wright BuildersFor:48 Bates Street, Northampton, MA 01060Phone: (413) 586-8287 Notes: Design Information Hartford Bradley Intl AP, CT, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F8 Outside db °F88Inside db °F70 Inside db °F75Design TD °F62 Design TD °F13Daily range MRelative humidity %50Moisture difference gr/lb27 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh11493 Structure Btuh10829DuctsBtuh4865DuctsBtuh5846Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0HumidificationBtuh0BlowerBtuh0PipingBtuh0Equipment load Btuh16358 Use manufacturer's data nRate/swing multiplier 0.93InfiltrationEquipment sensible load Btuh15574 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Average0Fireplaces Structure Btuh1488DuctsBtuh460 CoolingHeating Central vent (0 cfm)Btuh010661066Area (ft²)Equipment latent load Btuh194885288528Volume (ft³)Air changes/hour 0.190.37 Equipment total load Btuh17523Equiv. AVF (cfm)2753 Req. total capacity at 0.70 SHR ton1.9 Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/aModeln/a Cond n/aAHRI ref n/a Coil n/aAHRI ref n/aEfficiencyn/a Efficiency n/aHeating input Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0Low output baseboard Btuh/ft500 Total cooling Btuh0Total low baseboard ft0 Actual air flow cfm0High output baseboard Btuh/ft700 Air flow factor cfm/Btuh0Total high baseboard ft0 Static pressure in H2O0Space thermostat n/a Load sensible heat ratio 0 Job #: Performed by Nathan LeMay for: Mark Ledwell 48 Bates Street Northampton, MA 01060 Phone: (413) 586-8287 A Plus HVAC Inc. 26 Airport Drive Westfield, MA 01085 Phone: (413) 562-0054 Fax: (413) 562-0064 www.aplushvacinc.com nathan@aplushvacinc.com Scale: 1 : 75 Page 1 Comfort Builder by Wrightsoft 15.0.19 RSU02778 2016-Mar-08 16:11:57 ...d New Home\Feinland Load Cal.rup N Second floor Master Bedroom Bedroom 4 Bedroom 3 Bedroom 2 Bath 2 Master Bath Hallway 147 cfm 131 cfm 160 cfm 93 cfm93 cfm 47 cfm 160 cfm131 cfm 227 cfm 147 cfm 16 cfm 16 cfm Job #: Performed by Nathan LeMay for: Mark Ledwell 48 Bates Street Northampton, MA 01060 Phone: (413) 586-8287 A Plus HVAC Inc. 26 Airport Drive Westfield, MA 01085 Phone: (413) 562-0054 Fax: (413) 562-0064 www.aplushvacinc.com nathan@aplushvacinc.com Scale: 1 : 75 Page 2 Comfort Builder by Wrightsoft 15.0.19 RSU02778 2016-Mar-08 16:11:57 ...d New Home\Feinland Load Cal.rup N First floor Living / Kitchen Bedroom 5 Bath 1 Foyer 139 cfm 139 cfm 139 cfm 331 cfm 189 cfm 139 cfm139 cfm 51 cfm111 cfm 51 cfm Sup Riser 14 x 10 Ret Riser 14 x 10 8 " 14 x 10 7 "7 " 6 " 6 " 6 " 7 " 14 x 10 6 " 8 " 7 " 6 " Job #: Performed by Nathan LeMay for: Mark Ledwell 48 Bates Street Northampton, MA 01060 Phone: (413) 586-8287 A Plus HVAC Inc. 26 Airport Drive Westfield, MA 01085 Phone: (413) 562-0054 Fax: (413) 562-0064 www.aplushvacinc.com nathan@aplushvacinc.com Scale: 1 : 75 Page 3 Comfort Builder by Wrightsoft 15.0.19 RSU02778 2016-Mar-08 16:11:57 ...d New Home\Feinland Load Cal.rup N Basement Room1 258 cfm 8 " 7 " 7 " 7 " 7 " 6 " 6 " 6 " 10 " 12 x 8 Sup Riser 14 x 10 18 x 8 Ret Riser 14 x 10 14 x 10 6 " 14 x 10