Loading...
HERS-568 84 Musante Dr HERS certificate84 Musante Dr Northampton, MA 01060 5 Stars Plus Confirmed Registry ID: 279130701 Rating Number: HERS-568 Certified Energy Rater: David Gagne Rating Date: 2/8/17 Rating Ordered For: Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 24.3 $353 22% Cooling 1.8 $91 6% Hot Water 13.9 $197 12% Lights/Appliances 18.7 $952 60% Photovoltaics -0.0 $-0 -0% Service Charges $0 0% Total 58.7 $1593 100% This home meets or exceeds the minimum criteria for all of the following: TITLE Company Address City, State, Zip Phone # Fax # Uniform Energy Rating System 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less Energy Efficient HERS Index:52 General Information Conditioned Area: 1697 sq. ft. HouseType: Apartment, end unit Conditioned Volume: 20520 cubic ft. Foundation: Conditioned basement Bedrooms: 3 Mechanical Systems Features Heating: Fuel-fired air distribution, Natural gas, 97.0 AFUE. Cooling: Air conditioner, Electric, 16.5 SEER. Water Heating: Instant water heater, Natural gas, 0.95 EF, 0.0 Gal. Duct Leakage to Outside: 0.00 CFM25. Ventilation System: Balanced: ERV, 54 cfm, 24.0 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Building Shell Features Ceiling Flat: NA Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Exposed Floor: R-30.0 Vaulted Ceiling: R-42.8 Window Type: U-Value: 0.300, SHGC: 0.250 Above Grade Walls: R-26.0 Infiltration Rate: Htg: 331 Clg: 331 CFM50 Foundation Walls: R-10.1 Method: Blower door test Lights and Appliance Features Percent Interior Lighting: 100.00 Range/Oven Fuel: Electric Percent Garage Lighting: 100.00 Clothes Dryer Fuel: Electric Refrigerator (kWh/yr): 645.00 Clothes Dryer EF: 3.01 Dishwasher (kWh/yr): 275.00 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v14.6.3.1 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado.