Loading...
HERS-529 78 Moser St air leakage reportAir Leakage Property 78 Moser St Northampton, MA 01060 Weather:Northampton, MA HERS-529 78 Moser St registered.blg Organization Power House Energy Consulting 413-835-5162 Matthew Turcotte Builder Pecoy Companies Whole House Infiltration ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole-building' requirement under that version of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v14.6.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. HERS Confirmed 5/23/16 Rating No:HERS-529 Rater ID:1497133 Duct Leakage Ventilation Blower Door Test Heating Cooling Natural ACH 0.11 0.08 ACH @ 50 Pascals 1.74 1.74 CFM @ 25 Pascals 320 320 CFM @ 50 Pascals 502 502 Eff. Leakage Area (sq.in) 27.6 27.6 Specific Leakage Area 0.00014 0.00014 ELA/100 sf shell (sq.in) 0.61 0.61 Leakage to Outside Units ducts CFM @ 25 Pascals 0 CFM25 / CFMfan 0.0000 CFM25 / CFA 0.0000 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 0 Eff. Leakage Area (sq.in) 0.00 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.1155 Mechanical Balanced ASHRAE Sensible Recovery Eff. (%) 67.0 62.2-2010 Total Recovery Eff. (%) 52.0 Rate (cfm) 46 37 Hours/Day 24.0 24.0 Fan Watts 24.0 Cooling Ventilation Natural Ventilation