Loading...
119 Moser St Final Air Leakage ReportAir Leakage Property119 Moser StNorthampton, MA 01060 Weather:Northampton, MAHERS-528 119 Moser Stregistered.blg OrganizationPower House Energy Consulting413-835-5162Jamie Callan BuilderPecoy Companies Whole House Infiltration ASHRAE 62.2 - Ventilation RequirementsThe ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole-building'requirement under that version of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittentmechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hoursper day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer tothe appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v14.6.4This information does not constitute any warranty of energy cost or savings.© 1985-2016 Noresco, Boulder, Colorado. HERSConfirmed9/2/2016Rating No:HERS-528Rater ID:3463906 Duct Leakage Ventilation Blower Door TestHeating CoolingNatural ACH 0.05 0.04ACH @ 50 Pascals 1.04 1.04CFM @ 25 Pascals 177 177CFM @ 50 Pascals 278 278Eff. Leakage Area (sq.in) 15.3 15.3Specific Leakage Area 0.00010 0.00010ELA/100 sf shell (sq.in) 0.35 0.35 Leakage to Outside Units ductsCFM @ 25 Pascals 0CFM25 / CFMfan 0.0000CFM25 / CFA 0.0000CFM per Std 152 N/ACFM per Std 152 / CFA N/ACFM @ 50 Pascals 0Eff. Leakage Area (sq.in) 0.00Thermal Efficiency N/ATotal Duct Leakage Units CFM25/CFATotal Duct Leakage 0.1257 Mechanical Balanced ASHRAESensible Recovery Eff. (%) 67.0 62.2-2010Total Recovery Eff. (%) 0.0Rate (cfm) 64 25Hours/Day 24.0 24.0Fan Watts 30.0Cooling Ventilation Natural Ventilation