Loading...
fw15higginswayfinalhersreports-2 HERS-961 15 Higgins Way HERS certificate.pdfHERCCert Home Energy Rating Certificate HERS Index: 55 REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. General Information Conditioned Area 1349 sq. ft. House Type Single-family detached Mechanical Systems Features Air-source heat pump: Electric, Htg: 11.0 HSPF. Clg: 18.0 SEER. Building Shell Features Ceiling Flat R-54.1 Slab R-0.0 Edge, R-0.0 Under Lights and Appliance Features Percent Interior Lighting 100.00 Range/Oven Fuel Propane Estimated Annual Energy Cost Use MMBtu Cost Percent Heating 13.7 $696 43% Criteria This home meets or exceeds the minimum criteria for the following: 2015 International Energy Conservation Code Conditioned Volume 16278 cubic ft. Foundation Conditioned basement Water Heating: Heat pump, Electric, 3.17 EF, 66.0 Gal. Sealed Attic NA Exposed Floor NA Percent Garage Lighting 100.00 Clothes Dryer Fuel Propane Power House Energy Consulting Cooling 0.5 $23 1% Bedrooms 2 Duct Leakage to Outside NA Vaulted Ceiling R-43.2 Window Type U-Value: 0.300, SHGC: 0.250 Refrigerator (kWh/yr) 645 Clothes Dryer CEF 3.30 479 West St. Suite 105 Hot Water 2.6 $134 8% Ventilation System Balanced: HRV, 52 cfm, 55.0 watts. Above Grade Walls R-26.0 Infiltration Rate Htg: 486 Clg: 486 CFM50 Dishwasher (kWh/yr) 270 Ceiling Fan (cfm/Watt) 0.00 Amherst, MA 01002 Lights/Appliances 16.4 $764 47% Programmable Thermostat Heat=Yes; Cool=Yes Foundation Walls R-10.1 Method Blower door test 413-230-3043 Photovoltaics -0.0 $-0 -0% Service Charges $0 0% Total 33.2 $1618 100% Property HERS Rating Type: Confirmed Certified Energy Rater: David Gagne 15 Higgins Way Rating Date: 2017-10-30 Rating Number: HERS-961 Northampton, MA 01060 Registry ID: 698927100 HERS-961 15 Higgins Way air leakage report.pdfAirLeakage Air Leakage Property 15 Higgins Way Northampton, MA 01060 Weather:Chicopee, MA HERS-961 15 Higgins Way registered.blg Organization Power House Energy Consulting 413-230-3043 David Gagne Builder Pecoy Companies Whole House Infiltration ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole-building' requirement under that version of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v15.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Confirmed 2017-10-30 Rating No:HERS-961 Rater ID:7013322 Duct Leakage Ventilation Blower Door Test Heating Cooling Natural ACH 0.10 0.08 ACH @ 50 Pascals 1.79 1.79 CFM @ 25 Pascals 310 310 CFM @ 50 Pascals 486 486 Eff. Leakage Area (sq.in) 26.7 26.7 Specific Leakage Area 0.00014 0.00014 ELA/100 sf shell (sq.in) 0.63 0.63 CFM50/sf shell 0.12 0.12 Leakage to Outside Units CFM @ 25 Pascals CFM25 / CFMfan CFM25 / CFA CFM per Std 152 CFM per Std 152 / CFA CFM @ 50 Pascals Eff. Leakage Area (sq.in) Thermal Efficiency Total Duct Leakage Units Total Duct Leakage Mechanical Balanced ASHRAE ASHRAE Sensible Recovery Eff. (%) 63.0 62.2-2010 62.2-2013 Total Recovery Eff. (%) 0.0 Rate (cfm) 52 36 47 Hours/Day 24.0 24.0 24.0 Fan Watts 55.0 Cooling Ventilation Natural Ventilation