Report 13 Community Village
Report No. 13 of Soils Tests Date: 06/24/2008
Client: The Community Builders, Inc.
Project: Village At Hospital Hill, Phase II, Northampton, MA
Subject: Soils Tests
Reported to: The Community Builders, Inc. – Attention: Mr. Tom Kegelman
TEST: DENSITY OF SOIL IN PLACE BY NUCLEAR METHOD – ASTM D2922
Test Dry Moisture Maximum
No. Location Density Content Density Compaction
(pcf) (%) (pcf) (%)
1 Building A1 – N1 125.9 6.7 131.0 96.1
2 Building A1 – N2 125.3 6.4 131.0 95.7
3 Building A1 – N3 127.7 7.2 131.0 97.5
4 Building A1 – S4 124.4 6.7 131.0 95.0
Respectfully submitted,
ALLIED TESTING LABORATORIES, INC.
By: Richard Bellucci
President
Copy:
S. Fish, Community Builders
S. Drumm, Community Builders
T. Welch, Williams Construction
W. Barry, Barry Engineers
M. Sternick, Dietz & Co.
M. Talbot, O’Reilly, Talbot & Okun
I. Hasbrouck, Northampton Building Department
P. Labadorf, Labadorf Assoc.