Coach House Electric-alarm 1-24-18BASEMENT LEVEL POWER PLANSCALE: 1/4 = 1'-0"Xref ..\Xrefs\1092 Basement rm name.dwg1KEY NOTESPROVIDE POWER FROM FIRST FLOOR CIRCUIT TO SERVE RECEPTACLE(S)1GFI-WPFACPOPP-5OPP-3JOPP-1ERV1GFI-WPGFI-WPFAIMCOAIMCOFFFFFFSSSSSGFIOPP-7TP1EUH1OPPSMEUH2OPPSMEUH3OPPSMSMEDH1TP1SMEF1OPPDH2OPPSMDH1OPPSMOPP1/4" = 1' - 0"EP1.0JPBasement LevelPower PlanJPJANUARY 24, 2018LLCArchitecture, Planning, Interior Design413 . 586 . 1600JUSTER POPE FRAZIERNorthampton, Massachusetts 0106082 North StreetREMARKSREVISIONSNO.DATESHEET TITLEDATESCALEDRAWN BYSHEET NO.CHECKED BYNorthampton, MA88 Village Hill RoadVillage Hill - Coach HouseWEATHERBY DESIGN & CO. ENGINEERS772 Union Street, PO Box 976 Wes t Springf ie ld , MA 01090MECHANICALELECTRICAL PLUMBINGPERMIT DRAWINGS FIRST FLOOR POWER PLANSCALE: 1/4 = 1'-0"wall heater, recessedUPGENERAL NOTESBATTERY TYPE EGRESS FIXTURES (TYPE XE, E, EB, & X) SHALL BE POWEREDFROM UNSWITCHED BRANCH CIRCUIT WIRING SERVING LOCAL AREALIGHTING FIXTURES W/ 2#12+#12G (UNLESS OTHERWISE NOTED)SUPPORT REMOTE TYPE EGRESS FIXTURES FROM BATTERY SUPPLIESWHERE SHOWN, USING 2#12+#12G.KEY NOTESPOWER CONNECTION TO SUPPORT HVAC EQUIPMENTCOORDINATE WITH EXHAUST HOOD INSTALLATION184"84"84"84"84"84"84"GFIGFIGFIGFIHP2ATP1GFIGFIJ1HP2BTP1HP2CTP1HP 1TP1HP3ATP1EH 2OPPJ1HP3BTP1HP3CTP1HP3DTP1HP3ETP1EH 1TP1SMSMJ22GFIGFIGFIGFISKFACPFFFJCOAIMFFFFFFFFFCOAIMS84"84"84"1/4" = 1' - 0"EP1.1JPFirst FloorPower PlanJPJANUARY 24, 2018LLCArchitecture, Planning, Interior Design413 . 586 . 1600JUSTER POPE FRAZIERNorthampton, Massachusetts 0106082 North StreetREMARKSREVISIONSNO.DATESHEET TITLEDATESCALEDRAWN BYSHEET NO.CHECKED BYNorthampton, MA88 Village Hill RoadVillage Hill - Coach HouseWEATHERBY DESIGN & CO. ENGINEERS772 Union Street, PO Box 976 Wes t Springf ie ld , MA 01090MECHANICALELECTRICAL PLUMBINGPERMIT DRAWINGS SECOND FLOOR POWER PLANSCALE: 1/4 = 1'-0"Xref ..\Xrefs\1092 2nd floor rm name.dwgGFIGFIGFIGFIGFIGFIGFIGFIGFIGFIGFIGENERAL NOTESPROVIDE TAMPER RESISTANT RECEPTACLES THROUGHOUT ALL DWELLINGUNIT AREAS.PROVIDE ARC FAULT PROTECTION TO ALL 20A BRANCH CIRCUITS SERVINGDWELLING UNITS, WHERE REQUIRED BY NFPA 72 ARTICLE 210.12PROVIDE GROUND FAULT RESET IN ACCESSIBLE LOCATION. WHERE GFIPROTECTION IS REQUIRED, BEHIND EQUIPMENT LOCATION, IT SHALL BEPROVIDED AT THE PANELBOARD.KEY NOTESPOWER CONNECTION TO SUPPORT HVAC EQUIPMENTCOORDINATE WITH EXHAUST HOOD INSTALLATION12GFIGFIGFIGFIXref ..\Xrefs\1092 2nd floor rm name.dwgGFIGFIGFIGFIGFIGFIGFIGFIGFIGFIGFIAIMCOFSFFFSSSAIMCOAIMCOSSSERV1TP1SMEDH1TP1EH3SMEH4SMTP1TP1TP1SMHP4CTP1SMHP4DJ1J2J2J1SMEH5SMEH6TP2TP2TP2SMHP5CTP2SMHP5CTP2TP1 HP5ATP2SMHP4ATP1SM1/4" = 1' - 0"EP1.2JPSecond FloorPower PlanJPJANUARY 24, 2018LLCArchitecture, Planning, Interior Design413 . 586 . 1600JUSTER POPE FRAZIERNorthampton, Massachusetts 0106082 North StreetREMARKSREVISIONSNO.DATESHEET TITLEDATESCALEDRAWN BYSHEET NO.CHECKED BYNorthampton, MA88 Village Hill RoadVillage Hill - Coach HouseWEATHERBY DESIGN & CO. ENGINEERS772 Union Street, PO Box 976 Wes t Springf ie ld , MA 01090MECHANICALELECTRICAL PLUMBINGPERMIT DRAWINGS ATTIC LEVEL POWER PLANSCALE: 1/4 = 1'-0"Xref ..\Xrefs\1092 Attic rm name.dwgSFAIMCOSAIMCOSGFIGFIHP4BTP1SMHP5BTP2SMSMEDH2TP1SMEDH3TP2ERV2TP1ERV3TP11/4" = 1' - 0"EP1.3JPAttic LevelPower PlanJPJANUARY 24, 2018LLCArchitecture, Planning, Interior Design413 . 586 . 1600JUSTER POPE FRAZIERNorthampton, Massachusetts 0106082 North StreetREMARKSREVISIONSNO.DATESHEET TITLEDATESCALEDRAWN BYSHEET NO.CHECKED BYNorthampton, MA88 Village Hill RoadVillage Hill - Coach HouseWEATHERBY DESIGN & CO. ENGINEERS772 Union Street, PO Box 976 Wes t Springf ie ld , MA 01090MECHANICALELECTRICAL PLUMBINGPERMIT DRAWINGS