Building Design Criteria! RYAN S. HELLWIG, PE ! STRUCTURAL ENGINEER ! September 29, 2010 Re:New Horse Barns General Design Criteria 3 County Fairgrounds 41 Fair Street Northampton, Mass. Building Design Criteria per Chapter 16, Massachusetts State Building Code, 7 Edition.th Building Classification Category I - Agricultural Facilities rRoof:Live Load L = 19 psf Snow:Ground Snow Load = 55 psf Importance Factor I = 0.8 tTemperature Factor C = 1.2 - Unheated Building eExposure Factor C = 1.0 fFlat Roof Snow Load: p = 37 psf sSloped Roof Factor C = 1.0 - 5:12 pitch w/o slippery, unobstructed surface Unbalanced snow loads = 55 psf on leeward side + 11 psf on windward side Wind:Wind Speed V = 100 mph (3 second gust) Importance Factor I = 0.87 Exposure B Method 1 - Simplified Procedure Adjustment Factor for Height & Exposure ë = 1.00 Flood:Base Flood Elevation BFE = 125 ft Appendix §120.G501.4 - Enclosed spaces below the BFE shall not be used for human occupancy, except egress, incidental storage, etc. Fully enclosed spaces shall be designed to automatically equalize hydrostatic forces by allowing for entry and exit of floodwaters. ASCE 24 - Table 1-1, Footnote a - Certain agricultural structures may be exempt from some of the flood-proofing provisions per §C1.4.3 ASCE 24 §C1.4.3 - Certain agricultural structures may be wet flood-proofed. Seismic:§1614.1.2 - Agricultural buildings w/ incidental human occupancy are exempt from the requirements of the Earthquake Loads provisions ! 28 ALDRICH STREET ! NORTHAMPTON, MA 01060 ! ! Voice = 413-584-HLWG (4594) ! Fax = 413-584-HLWFax (4593) ! Email = rshpe@crocker.com !