8 Bedford Fire Protection 2016-05-17FIRE PROTECTION BASEMENT PLAN - DEMOLITION SCALE: 1/4" = 1'-0" 1-1/4" RISER 3" RISER 3"1-1/2" 1" 1" 1-1/4" 3" 3" 1" 1-1/2"1" 1"1" 1" 4" 1"1"1-1/2"1-1/2" 1" 4" 4" 3" 1" 1" 1" 1-1/2" 1" 1-1/2" 2-1/2" 4" 4"2-1/2" 2" 1" 1" 1" 1-1/2" 1" 2" 2" 1" 2-1/2" 1-1/2" 1-1/2" 1" 1" 1" 2"2" 1" 1-1/2" 4" RISER 2" 1" RISER T T 1" DRAIN 2" DEMOLITION NOTES: DISCONNECT EXISTING SPRINKLER RISER. DISCONNECT & REMOVE EXISTING SPRINKLER RISER. CAP PIPING BACK AT MAIN. DISCONNECT EXISTING DRAINS AND RELOCATE. DISCONNECT WATER MOTOR GONG AND RELOCATE. DISCONNECT FIRE DEPARTMENT PUMPER AND RELOCATE. DISCONNECT AND REMOVE EXISTING SPRINKLER LINE FOR INSTALLATION OF NEW STRUCTURAL MEMBERS. 4" RISER CRAWL SPACE SIDE PORCH OFFICE ENTRY HALL ENTRY VESTIBULE CONFERENCE 1CONFERENCE 2 CLO. MEN'S TOILET WOMEN'S TOILET STAIR HALL FRONT PORCH CLO. CLO. COMMERCIAL KITCHEN EXPANDED COMMERCIAL KITCHEN SERVERYMOP CLOSET ALL-GENDER/ UNISEX ACCESSIBLE TOILET DINING CLO. FIRE PROTECTION FIRST FLOOR PLAN - DEMOLITION SCALE: 1/4" = 1'-0" BACK HALL DEMOLITION NOTES: REMOVE EXISTING SPRINKLER RISER. DISCONNECT & REMOVE EXISTING SPRINKLER HEAD AND ASSOCIATED PIPING. DISCONNECT & REMOVE EXISTING PENDANT HEAD. UPRIGHT HEAD TO REMAIN. REMOVE EXISTING SIDEWALL SPRINKLER HEAD. 1-1/4" RISER DN. 4" RISER UP & DN. 1"1" 1" 1-1/2" 2-1/2" 2-1/2" 1" 4" RISER 1" RISER UP 2-1/2" 1-1/2" 4" 1" 1" 1" 2-1/2" 1-1/2" 1" 1"3"3" 1-1/4" 1" 3" 3" 1" RISER DN. 1" 1-1/2"1-1/2" 3" RISER 2-1/2" 2"2"2" 1" 1" 1" 1" 1-1/2"2"2" 1" DRAIN 1" DRAIN 1"1-1/2" 1-1/2" 1"1" 1" 1-1/2" 1-1/4" DRAIN 1-1/4" 1" 1" 1" FIRE PROTECTION BASEMENT PLAN - PHASE III SCALE: 1/4" = 1'-0" CRAWL SPACE 1-1/4" RISER 3" RISER 3"1-1/2" 1" 1" 1-1/4" 3" 3" 1" 1-1/2"1" 1"1" 1" 1"1"1-1/2"1-1/2" 1" 4" 4" 3" 1" 1" 1" 1-1/2" 1-1/2" 2-1/2" 4" 4"2-1/2" 2" 1" 1" 1" 1-1/2" 1" 2" 2" 1" 2-1/2" 1-1/2" 1-1/2" 1" 1" 1" 2"2" 1" 1-1/2" 2" T T 1" DRAIN 2" 4" 4" CAP M CRAWL SPACE DRAWING NOTES: NEW 4" SPRINKLER RISER UP. CONNECT NEW 4" TO EXISTING HERE. RELOCATED DRAINS. EXTEND PIPING. RELOCATED WATER MOTOR GONG. EXTEND PIPING. RELOCATED FIRE DEPARTMENT PUMPER. EXTEND PIPING. EXISTING GAS SERVICE TO REMAIN. CONNECT NEW 2" TO EXISTING HERE. CONNECT NEW 1-1/4" TO EXISTING HERE. CONNECT NEW 1" TO EXISTING HERE. INSTALL NEW PIPING AND HEADS TO AVOID NEW STRUCTURAL MEMBERS. EXTEND NEW 4" PUMPER, 1-1/4" WATER MOTOR GONG AND 1-1/4" DRAIN LINES AS INDICATED. UP 21 3 4 5 6 8 A B A.1 C E F FIRE PROTECTION FIRST FLOOR PLAN - PHASE III SCALE: 1/4" = 1'-0" 107 108 115 116 117 111 110 101 102 104 105 106 114 113 112 39 109 103 DRAWING NOTES: NEW 4" SPRINKLER RISER DN. IN WALL. CONNECT EXISTING 1-1/2" TO NEW 4" HERE. CONNECT EXISTING 1-1/4" TO NEW 4" HERE. CONNECT EXISTING 3" TO NEW 4" HERE. CONNECT NEW 1" TO EXISTING 1-1/2" HERE. CONNECT NEW 2" TO EXISTING HERE. CONNECT NEW 4" TO EXISTING 4" RISER UP. CONNECT NEW 1" TO EXISTING HERE. RELOCATED PUMPER. RELOCATED WATER MOTOR GONG. RELOCATED DRAINS. RELOCATED ELECTRIC BELL. EXTEND NEW WIRING TO EXISTING CIRCUIT. EXISTING GAS SERVICE TO REMAIN. 1-1/4" RISER 1"1" 1-1/4"1-1/2" 2-1/2" 2-1/2" 1" 1" RISER UP 2-1/2" 1" 1" 1" 2-1/2" 1-1/2" 1" 1"3"3" 1-1/4" 1" 3" 3" 1-1/2"1-1/2" 3" RISER 2-1/2" 2"2"2" 1" 1" 1" 1" 1-1/2"2"2" 1" DRAIN 1" DRAIN 1"1-1/2" 1-1/2" 1-1/4" 1-1/2" 1-1/4" DRAIN 1-1/4" 1" 1" 1" 1" 4" 1" 1" 2" 2" 1" 1-1/2" CAP CAP M 1" 1" 1"1" 1"1" F T NOT TO SCALE BRANCH LINE PIPE HANGER PROVIDE INVERTED "U" PIPE CONNECTION EXTEND PIPE TO AVOID LIGHTS AND DIFFUSERS CEILING COVER PLATE PENDANT HEAD FINISH CEILING RECESSED PENDANT HEAD BRANCH LINE NOT TO SCALE BRANCH LINE PIPE HANGERFINISH WALL WALL COVER PLATE SIDEWALL HEAD NOT TO SCALE NOT TO SCALE BRANCH LINE CEILING COVER PLATE PENDANT HEAD FINISH CEILING UPRIGHT HEAD PROVIDE INVERTED "U" PIPE CONNECTION EXTEND PIPE TO AVOID LIGHTS AND DIFFUSERS PIPE HANGER UPRIGHT HEAD