Loading...
170113 Tilly Hall PERMIT SETCharlie Conant, Project Manager Smith College (413) 585-2424 cconant@smith.edu Laura Fitch, AIA, LEED BD+C Fitch Architecture & Community Design, Inc. 110 Pulpit Hill Road, Amherst, MA 01002 (413) 549-5799 (413) 687-2727 lfitch@facdarchitects.com Wright Builders, Inc. 48 Bates St. Northampton, MA 01060 (413) 586-8287 Codes and Other Sources 2009 International Existing Building Code (IEBC) 404 Level 2 Alternations Uses Use Group B: Offices and Educational occupancies for students above 12th grade. Construction Type VB (5B) Combustible, Unprotected Area Building Footprint: 2,650 SF first floor IEBC Chapter 7 703 Existing vertical openings: no requirement for enclosure for B uses less than 3,000 SF per floor 705 Means of Egress: n accordance with Mass amendment, Chapter 34) 102.2.2.1 major alternations - not applicable existing non conforming means of egress - not applicable 0.0 TITLE PAGE A-1.0 FIRST FLOOR NEW TOILET A-2.0 INT. ELEVATIONS NEW TOILET A-3.0 SECTION NEW TOILET TILLY HALL BASEMENT 002 002A 001 00M2 00M1 MECHANICALELEC. & DATA 640 sq. ft. 100ST3 exit to grade BASEMENT EGRESS / CONTEXT Scale: 1" = 20 ftB 3RD STAIR MODIFIED, BUT STILL CODE COMPLIANT TILLY HALL SECOND FLOOR 206 204 203 200K 200C 202 200 200ST2 200ST1DN REFRIGDN201 205 2,000 sq. ft. 2nd FLOOR CONTEXT Scale: 1" = 20 ft2 705.3 Number of exits - every story shall have min. number of exits based on ooccupacy and occupant load per IBC Occupancy Load: Egress load Basement +/-564 SF / 300 = 2 occupants Egress load first floor +/-2,650 gross SF / 100 = 27 occupants Egress load second floor +/-2,000 gross SF / 100 = 20 occupants Number of Exits: Basement: 2 existing First Floor: 3 existing Second Floor: 2 interior stairs, 1 fire escape Plumbing Existing facilities: Basement: 2 private toilet rooms, (1) with 2 toilets and 2 sinks (1) private First Floor: none, one proposed Second Floor: 2 private toilet rooms Table 1: Minimum Facilities for Building Occupancy Business Offices Female: 1 per 20 1 or 2 required, 3 provided Male: 1 per 25 1 or 2 required, 2 provided Lavatory: 1 per 50 Drinking fountain: 1 per floor Service Sink: 1 per floor Note m: Handicap Toilet Facility Requirements: 3. Unisex handicap toilets may be allowed. variance is not required if total fixtures meet requirements of Table 1 4. Drinking fountains shall be accessible 8'-3"6'-8"4"1st FLOOR CONTEXT Scale: 1" = 20 ft1 SMITH COLLEGE, NORTHAMPTON,MA TILLY HALL PERMIT SETFITCH ARCHITECTURE & COMMUNITY DESIGN HOME COMMUNITY PLANETTILLY HALL SMITH COLLEGENORTHAMPTON, MAJAN 13, 2017 TITLE PAGE 0.0 REVISIONS: DATENUMBER 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799Fax: 413-549-7918 www.facdarchitects.com PERMIT SETFITCH ARCHITECTURE & COMMUNITY DESIGN HOME COMMUNITY PLANETTILLY HALL SMITH COLLEGENORTHAMPTON, MAJAN 13, 2017 TITLE PAGE 0.0 REVISIONS: DATENUMBER 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799Fax: 413-549-7918 www.facdarchitects.com 3'-4" MO3'-4" MO 4'-8"8'-0" +/- 2'-10" +/-7'-11" +/- 1'-7 3/4"3'-2 1/2" +/-1'-1 1/2"9 1/2"2'-9 1/4"3'-2 1/4" +/-1'-8 1/4" +/- 4'-11" +/-2'-0"7'-3" +/-20'-0" +/-2'-0"3'-0"9'-3" +/- STAIR RUN BELOW 100T2 100ST REDUCE WIDTH OF BASEMENT STAIR 7'-6"4 3/4"6'-9"6 1/8"REPLACE EXISTING WINDOWS WITH DOORS. NEW WOOD TRIM TO MATCH EXISTING AND NEW WOOD THRESHOLD. NEW NATURAL LINOLEUM FLOOR EXISTING WINDOWS TO REMAIN 2" RIGID INSULATION + 1/2" GYP. BD 1/A-2.0 2/A-2.02" RIGID INSULATION + 2x4 STUD WALL + 5/8" GYP. BD 2 5/8" RECESS FOR BOTTLE FILLER (3 - 15/16" DEEP X 15" WIDE X 30 1/4" HIGH) 60" x18" CLEAR AT PULL SIDE OF DOOR OPENING (TYP) 18" DEEP X 42" WIDE CHROME WIRE SHELF (WALL MOUNT, BACK) - NEXEL, BY GLOBAL INDUSTRIES OR EQUAL8'-3"6'-8"4"INSTALL FRP TO 42" ON ALL WALL SURFACES WITHIN CUSTODIAL CLOSET, CAULK TO MOP BASIN MOP RACK: BOBRICK B-223 X 24. 100CL1+/-1'-10 1/2"SILLNEW ELECTRICE BASEBOARD NEW TOILET ROOMS FIRST FLOOR Scale: 1/2" = 1'-0"1 PERMIT SETFITCH ARCHITECTURE & COMMUNITY DESIGN HOME COMMUNITY PLANETTILLY HALL SMITH COLLEGENORTHAMPTON, MAJAN 13, 2017 FIRST FLOOR NEW TOILET A-1.0 REVISIONS: DATENUMBER 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799Fax: 413-549-7918 www.facdarchitects.com PERMIT SETFITCH ARCHITECTURE & COMMUNITY DESIGN HOME COMMUNITY PLANETTILLY HALL SMITH COLLEGENORTHAMPTON, MAJAN 13, 2017 FIRST FLOOR NEW TOILET A-1.0 REVISIONS: DATENUMBER 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799Fax: 413-549-7918 www.facdarchitects.com 42 " MIN 42"6-12" MAX 24" MIN17-19" TO TOP OF SEAT8'-3"6'-8"4"+/-1'-10 1/2"SILLWOOD BASE, PAINTED TOILET SIDE ELEVATION Scale: 1/2" = 1'-0"2 PERMIT SETFITCH ARCHITECTURE & COMMUNITY DESIGN HOME COMMUNITY PLANETTILLY HALL SMITH COLLEGENORTHAMPTON, MAJAN 13, 2017 INT. ELEVATIONS NEW TOILET A-2.0 REVISIONS: DATENUMBER 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799Fax: 413-549-7918 www.facdarchitects.com PERMIT SETFITCH ARCHITECTURE & COMMUNITY DESIGN HOME COMMUNITY PLANETTILLY HALL SMITH COLLEGENORTHAMPTON, MAJAN 13, 2017 INT. ELEVATIONS NEW TOILET A-2.0 REVISIONS: DATENUMBER 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799Fax: 413-549-7918 www.facdarchitects.com 33-36" 40" MAX6"MAX PAPER TOWEL HOLDER APPROX CEILING HEIGHT6-12" MAX 8'-3"6'-8"4"GRAB BAR 4'-0" TO ATTACH AT SIDE OF WINDOW HP ACCESSIBLE SINK-MAX 6" DEEP FAUX BEAD BOARD WAINSCOTING 48" HIGH+/-1'-10 1/2"SILL18" MIRROR 4'-0" TOILET BACK ELEVATION Scale: 1/2" = 1'-0"1 ACCESSORIES: TP DISPENSER: BOBRICK B-2740 (NO CONTROLLED DELIVERY)(BACKING REQ.) MIRROR - CONTRACTOR PURCHASE - BOBRICK B-165 2448(BACKING REQ.) PAPER DISPENSER - SMITH SUPPLY, CONTRACTOR INSTALL (BACKING REQ.) SOAP DISPENSER - SMITH SUPPLY, CONTRACTOR INSTALL (DOUBLE FACE FOAM TAPE -ADHERETO MIRROR) GRAB BARS (4): 42” LONG, S.S., PEENED GRIPPING SURFACE COAT HOOK VENTILATION: (2) PANASONIC VF-10VLSE 100 CFM CONTROLLED BY TIMER SWITCH PLUMBING FIXTURES: TOILET SHALL BE 1.1 GAL PRESSURE ASSIST LIGHTING: LED FIXTURES, CEILING AND VANITY ON SAME SWITCH PERMIT SETFITCH ARCHITECTURE & COMMUNITY DESIGN HOME COMMUNITY PLANETTILLY HALL SMITH COLLEGENORTHAMPTON, MAJAN 13, 2017 SECTION NEW TOILET A-3.0 REVISIONS: DATENUMBER 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799Fax: 413-549-7918 www.facdarchitects.com PERMIT SETFITCH ARCHITECTURE & COMMUNITY DESIGN HOME COMMUNITY PLANETTILLY HALL SMITH COLLEGENORTHAMPTON, MAJAN 13, 2017 SECTION NEW TOILET A-3.0 REVISIONS: DATENUMBER 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799Fax: 413-549-7918 www.facdarchitects.com7'-7 1/2"BASEMENT WINDOW IN FRONT 6'- 8 " H E A D R O O O M CL E A R A N C E FLOOR LEVEL OF BASEMENT FIRST FLOOR FINISH LEVEL8'-3"6'-8"4"EXISTING CONCRETE STAIR APPROX DOOR TO BASEMENT 7'-6" +/- 3'-2 1/2" M.O. +/- 2'-11" WINDOW +/-1'-10 1/2"SILL2" RIGID INSULATION + 3/4" STRAPPING + 5/8" GYP. BD 2" RIGID INSULATION + 2x4 STUD WALL + 5/8" GYP. BD 2x10 FRAMING FLASH FOAM INSULATION AT COLD SIDE BATT, BLOWN, OR FOAM REMAINDER OF CAVITY ATTIC TO RECEIVE BLOWN-IN CELLULOSE INSULATION, STRAP AND DRYWALL CEILING. SECTION Scale: 1/2" = 1'-0"1