Pages from 2017-9-15 AdamsRev Date Description
Project Title
ARCHITECTS
196 PLEASANT ST.
NORTHAMPTON,
MA 01060
413-585-0641
WWW.TDOUGLASARCHITECTS.COM
REGISTERED
ARCHITECT,
COMMONWEALTH OF
MASSACHUSETTS
This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed
by Thomas Douglas Architects is affixed in the space below.
The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS
DOUGLAS
Renovations to:
THE
CLARKE
SCHOOL
ADAMS
Northampton,
Massachusetts
Issue Date: 12/18/14
Drawn By:
Checked By:
Project ID:
Drawing No.
Sheet Title:
Scale:
EB
TD
AS NOTED
12/18/14 SCHEMATIC PROGRESS
14027
03/17/15 LAYOUT REVISIONS2
1
DETAILS AND
SCHEDULES
A-300
A EXISTING ALUMINUM CLAD REPLACEMENT WINDOW TO REMAIN -----
B CONFIRM EXISTING WINDOW MEETS EGRESS CLEARANCE.
C NEW WINDOW 2'9""5'1"ALUMINUM INSULATED WOOD CONFIRM EXISTING R.O.
D NEW WINDOW 2'9"2'0"ALUMINUM INSULATED WOOD
NEW WINDOW IN
ORIGINAL MASONRY
OPENING. CURRENTLY
WINDOW OPENING IS BOARDED-UP. PROPOSING TO RE-OPEN.NEW WOOD DOUBLE-HUNG WINDOW INSULATED, LOW E GLASS, CLEAR
WINDOW TYPES1
***CONFIRM EXISTING OPENING DIMENSIONS IN FIELD
C
D
2'-9"RO
2'-0"ROTYPICAL INTERIOR
WINDOW ELEVATION
REMOVE
WINDOW CASING. REINSTALL ON NEW GWB WALL.
TYPICAL EXTERIOR WINDOW
ELEVATION
SCRAP AND
PAINT EXISTING
WOOD TRIM
DOOR TYPES2
001 SCRAPE, REPAINT EXISTING DOORS ----CONFIRM EXISTING HARDWARE IS FUNCTIONAL
002 SIMPLE SWING 2'6"6'10"WOOD WOOD
003 DOUBLE SLIDER 2'6"6'10"WOOD WOOD
004 DOUBLE POCKET 2'6"6'10"WOOD WOOD
005 SINGLE POCKET 2'6"6'10"WOOD WOOD
006 SIMPLE SWING 3'0"6'10"WOOD WOOD FIRE RATED. TO FIT IN EXISTING OPENING
007 SIMPLE SWING 2'6"6'10"WOOD WOOD FIRE RATED.
008 DOUBLE POCKET 24'0"6'10"WOOD WOOD
2'-9"5'-1"A
2'-6"6'-10"TYPE 2 TYPE 3 TYPE 4 TYPE 5
2'-6"2'-6"2'-6"2'-6"2'-6"
NEW WOOD CASING TO MATCH EXISTING, TYP.
3'-0"
TYPE 6
2'-6"
TYPE 7 TYPE 8
2'-0"2'-0"
WALL TYPE 1 - FURRED EXTERIOR WALL4 5/8"- EXISTING MASONRY EXTERIOR WALL (TOP)
- 3-5/8" 25 GAUGE STEEL STUD OR 2X4 WOOD STUD 16" O.C.
- VAPOR BARRIER
- 1/2" AIR GAP
- 5/8" TYPE-X GWB
EXISTING BRICK WALL
AIR SPACE
DEMO EXISTING LATH
AND PLASTER
EXISTING BRICK WALL
1/2" AIR SPACE
NEW 5/8" GWB
EXISTING WALL SECTION
Scale: 1 1/2" = 1'-0"1 PROPOSED WALL SECTION
Scale: 1 1/2" = 1'-0"2 EXISTING MASONRY WALLEXISTING WOOD CASING.
RELOCATED TO NEW FURRED OUT
WALL.
EXISTING WINDOW TO REMAIN.
PAINT INTERIOR AND EXTERIOR.
NEW WOOD JAMB. PAINTED.
NEW WOOD SILL. PAINTED.
PROPOSED DETAIL AT WINDOW
Scale: 1 1/2" = 1'-0"3
EXISTING BROWNSTONE STILL
EXISTING WOOD
STUDS TO REMAIN
NEW BLOWN
INSULATION
BETWEEN
EXISTING WOOD
STUDS. 3"