BEAVER_BROOK-01-22-2018_RECORD-DRAWING-FP-1INSPECTION TEST ANDPRESSURE SWITCHTO ACTIVATE PUMP)3 HP. WATER PUMP(SIGNALS CONTROLLERDRAIN VALVECONTROLLERw/ MOTOR STARTERCONTROL VALVETANK DRAIN VALVETO DRAINCHECK VALVE1 1/4" SUPPLY TO SPRINKLERS400 GALLON WATERSTORAGE TANKFLOW SWITCH1ST FLOOR9'-1"2ND FLOOR18'-2"BASEMENT F.F. 0'-0"SYMCNTMFGSINSTYLERESPONSEKORIFNPTHEADTEMPCOVERTEMPESCUTCHGUARDFINISHNOTES10RELIABLERES49PENDENTQUICK4.97/16"1/2"155°N/AN/AN/ACHROMEQUICK RESPONSE PENDENT17RELIABLERFC49CONCEALEDQUICK4.97/161/2"155°135°CONCEALEDN/AWHITEQR WHITE COVERPLATE25RELIABLERES44SIDEWALLQUICK4.47/161/2"155°N/ARECESSEDN/AWHITEQUICK RESPONSE HSWSPRINKLER HEADS WITHIN 2'-6" OF ALL DIFFUSERS SHALL BE INTERMEDIATE TEMPERATUREHYDRAULIC REMOTE AREA SOURCE:SIZE:BASE OF RISER:LOCATION:FT²PSIPSIGPM @GPM @HAZARD:DENSITY:HEADS:GPM/FT²HOSE:GPMSYSTEM SAFETY FACTOR:PSI1BED/BATH2 HEADS2RES.05033.6634.6333.6642.2912.68BED 3BED 2BONUSMASTER1" RISER FROMFIRST FLOORTWO 45 DEG.CPVC ELBOWSBATHBATHKITCHENSLOPEDCEILINGSLOPEDCEILINGSLOPED CEILINGSLOPEDCEILING114" RISERFROM FIRSTFLOOR114" RISERFROM FIRSTFLOOR114" RISERFROM FIRSTFLOORNOTE: PIPING IN BONUS ROOM TOBE INSULATED BY OTHERS. SEEDETAIL ON SAME PAGEBASEMENT114" RISER FROMBASEMENTCONCRETE SLABON GRADECONCRETE SLABON GRADERUN INJOIST SPACERUN TIGHT TOBOTTOM OF JOISTSTUDYGARAGEDINING STOR.GREAT RM.NOOKSPRINKLERS ARE NOTREQUIRED IN GARAGES PERNFPA 13D PARAGRAPH 8.3.4114" RISER FROMBASEMENT,CONTINUE WITH114" FEED TOSECOND FLOOR114" RISER TOSECOND FLOOR1" RISER TOSECOND FLOOR114" RISER TOSECOND FLOORGENERAL NOTES:1.SYSTEM INSTALLATION TO CONFORM TO NFPA-13D, 2013 EDITION.2.OWNER IS REQUIRED TO PROVIDE HEAT THROUGHOUT THE ENTIRE BUILDING TO MAINTAINA MINIMUM TEMPERATURE OF 40° FAHRENHEIT FOR ALL AREAS PROTECTED WITH A WETPIPE SPRINKLER SYSTEM. THE SYSTEM IS TO BE MAINTAINED BY THE OWNER AS REQUIREDBY NFPA-25.3. PIPING:3.1.NEW WET SYSTEM EXPOSED PIPING 1" & LARGER TO BE SCHEDULE 40 BLACK STEELPIPING WITH SHOP WELDED OUTLETS OR FIELD INSTALLED MECHANICAL TEES ANDGROOVED ENDS AND FITTINGS.3.2.NEW WET SYSTEM PIPING INSIDE CEILING 2" & SMALLER TO BE CPVC PIPING WITH CPVCFITTINGS AND APPROVED SOLVENT CEMENT.4.PIPING TO BE SUPPORTED AS REQUIRED BY NFPA-13. HANGERS ARE TO BE FIELD LOCATEDTO BEST SUPPORT THE PIPE.5.STRUCTURAL LOAD BEARING ANALYSIS OF THE FIRE SPRINKLER SYSTEM AND IT'S RELATEDCOMPONENTS HAVE NOT BEEN INCLUDED AS PART OF THIS CONTRACT.6.WORK IS LIMITED TO SPRINKLER SCOPE INDICATED ON THIS DRAWING.7.SPRINKLER SCOPE TO START AT THE EXISTING SYSTEM PIPING WITHIN THE SPACE.8.NEW PIPE DIMENSIONS ARE APPROXIMATE. INSTALLER TO VERIFY PIPE LENGTH IN FIELD.9. DENOTES HYDRAULIC REFERENCE POINTS.SYSTEM NOTES:1.BUILDING CONSTRUCTION: COMBUSTIBLE1.1.OCCUPANCY: RESIDENTIAL1.2.DENSITY/AREA: 0.05 GPM/FT² OVER 2 MOST DEMANDING HEADS2.SPRINKLER OMISSIONS PER NFPA-13R SECTION 8.3.3 FOR CLOSETS: EXCEPT WHERE SPECIFIEDIN 6.6.4., SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, ANDPANTRIES WITHIN DWELLING UNITS THAT MEET ALL OF THE FOLLOWING CONDITIONS:2.1.THE AREA OF THE SPACE DOES NOT EXCEED 24 SQ. FT.2.2.THE LEAST DIMENSION DOES NOT EXCEED 3 FT2.3.THE WALLS AND CEILING ARE SURFACED WITH CON-COMBUSTIBLE OR LIMITEDCOMBUSTIBLE MATERIALS AS DEFINED IN NFPA 2203.SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS WHERE THE BATHROOM AREA DOESNOT EXCEED 55 SQ. FT.SPRINKLER NOTES:1.MANUFACTURER'S TECHNICAL DATA SHEET PARAMETERS2.RES44 SIDEWALL: MAXIMUM 16' BETWEEN SPRINKLER MAXIMUM 16' THROW, MAXIMUM 8' OFF WALLSMINIMUM 8' BETWEEN SPRINKLERS3.RFC49 CONCEALED PENDENT: MAXIMUM 18' BETWEEN SPRINKLER MAXIMUM 9' OFF WALLS MINIMUM 8' BETWEEN SPRINKLERS4.RES49 PENDENT: MAXIMUM 16' BETWEEN SPRINKLER MAXIMUM 16' THROW, MAXIMUM 8' OFF WALLSMINIMUM 8" BETWEEN SPRINKLERSPOSITIONING OF SPRINKLERS TO AVOIDDistance from Sprinklers toside of ObstructionsLess than 1 ft.1 ft to less than 1 ft 6 in1 ft 6 in to less than 2 ft2 ft to less than 2 ft 6 in2 ft 6 in to less than 3 ft3 ft to less than 3 ft 6 in3 ft 6 in to less than 4 ft4 ft to less than 4 ft 6 in4 ft 6 in to less than 5 ft5 ft to less than 5 ft 6 in5 ft 6 in to less than 6 ft6 ft to less than 6 ft 6 in6 ft 6 in to less than 7 ft7 ft to less than 7 ft 6 inMaximum Allowable Distanceof Deflector Above Bottom0011133577791114of Obstruction (in.)OBSTRUCTIONS TO DISCHARGE(Residential Upright/Pendents)POSITIONING OF SPRINKLERS TO AVOIDDistance from Sprinklers toside of ObstructionsLess than 8 ft.8 ft to less than 10 ft10 ft to less than 11 ft11 ft to less than 12 ft12 ft to less than 13 ft13 ft to less than 14 ft14 ft to less than 15 ft15 ft to less than 16 ft16 ft to less than 17 ft17 ft or greaterMaximum Allowable Distanceof Deflector Above BottomNot Allowed12346791114of Obstruction (in.)OBSTRUCTIONS TO DISCHARGE(Residential Sidewall Sprinklers)INSULATION DETAIL FOR ATTIC PIPENOT TO SCALE2X FRAMING BY OTHERSSPRINKLER PIPINGINSULATION BY OTHERSWIRE MESH BY OTHERSWATER PUMP: THREE HORSE POWERMANUFACTURER: TALCO FIRE SYSTEMSPUMP MODEL RFS20WATER STORAGE TANK CAPACITY: 400 GALLONSWATER TANK AND PUMP IN ACCORDANCE WITH NFPA 13D SECTION6.1.2, THE WATER SUPPLY SHALL MEETTHE REQUIRED DEMAND FOR A DURATION OF10 MINUTES.REQUIRED DEMAND IS 33.66 GPM.33.67 GPM x 10 MINUTES = 336.6 GALLONS.A 400 GALLON TANK WILL BE NEEDEDFOR AN ADEQUATE WATER SUPPLY.A 400 GALLON TANK WILL BE INSTALLED.FIRE PUMP TEST INFORMATIONFLOW:CONDUCTED BY:STATIC:RESIDUAL:ELEVATION:LOCATION:GPMPSIFTPSITEST DATE:TEST TIME:WITNESSED BY:534340BASEMENT3SECOND FLOOR PLANSCALE: 1/4" = 1'-0"2FIRST FLOOR PLANSCALE: 1/4" = 1'-0"1BASEMENT FLOOR PLANSCALE: 1/4" = 1'-0"4TANK & PUMP DETAILSCALE: 3/8" = 1'-0" NEW SPRINKLER PIPING EXISTING SPRINKLER PIPING REMOVE EXISTING SPRINKLER PIPING NEW MECHANICAL TIE TO EXISTING PIPING NEW ARMOVER FROM EXISTING OUTLETNEW MECH TIEDIMENSIONS REMOVE EXISTING SPRINKLER WITH 1" PLUGSAMMY SUPER SCREW "GST"WOOD JOISTWOOD JOISTSFLOOR ASSEMBLYCEILING SYSTEM(IF INSTALLED)SAMMY (GST)WOOD JOISTSAMMY "SWG"NOT LESS THAN 2" NOMINAL WIDTH (1-1/2")MINIMUM 2-1/2" FROM BOTTOMFOR BRANCHLINES, 3" FROMBOTTOM FOR MAINS.SIDEWINDER (SWG)3/8" A.T.R. FOR 1"-4" PIPEHANGER RING1/2" A.T.R. FOR 6"-8" PIPETOP BEAM CLAMP A.T.R. & RINGHANGER #1NOT TO SCALEROD LENGTH TOP BEAM CLAMPBSEE PLAN ASEISMIC RETAININGSTRAPSURGE RESTAINERSURGE RESTRAINERINSTALLED PER NFPA-131. AT THE END SPRINKLER ON A BRANCHLINE2. ON ARMOVERS SUPPLYING SPRINKLERS IN THE PENDENTPOSITION INSTALLED BELOW A CEILING:GREATER THAN 24" ON SYSTEMS LESS THAN 100 PSIGREATER THAN 12" ON SYSTEMS GREATER THAN 100 PSI1" X DROP(SEE PLAN)1" X 1/2" R.C. PENDENT W/ ESCT.(SEE PLAN)1" X ARMOVER1" 90 EL.EXISTING BRANCHLINESUSPENDED CEILINGTYP. RETURN BEND ASSEMBLY FROM BRANCHLINE(1" OUTLET or CHANGEFITTING IF REQUIRED)