CS loft I joists CalcCS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 HomsteadNeilXata - Level 10 10-17-17 4:06pm 1 of 2 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcA4 Member Type: Joist Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PSF Deck Connection: Glued & Nailed Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Other Start End Dead Start End Category Replacement Uniform (PSF) Top 13' 8.50" 24' 0.00" 0 10 Live Replacement Uniform (PSF) Top 0' 0.00" 13' 8.50" 20 10 Live Point (PLF) Top 0' 4.63" 1 239 Live Point (PLF) Top 0' 4.63" 525 0 Snow Point (PLF) Top 23' 7.38" 1 159 Live Point (PLF) Top 23' 7.38" 525 0 Snow 1 2 3 4 11 12 19 0 4 24 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 946# -- 2 4' 11.750" Wall SPF Plate (425psi) N/A 3.500" 656# -- 3 24' 0.000" Wall SPF Plate (425psi) N/A 1.500" 1011# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 -101#(-76plf) 700#(525plf) 246#(185plf) 2 373#(280plf) 0#(0plf) 283#(212plf) 3 30#(23plf) 700#(525plf) 311#(233plf) Design spans 4' 7.125" 18' 7.625" Product: 9-1/2" AJS 20 16.0" O.C.PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 612.'# 3395.'# 18% 14.3' Even Spans D+L Negative Moment 963.'# 3395.'# 28% 4.98' Total Load D+L Shear 354.# 1160.# 30% 4.98' Total Load D+L End Reaction 128.# 1175.# 10% 24' Even Spans D+L Int. Reaction 656.# 2350.# 27% 4.98' Total Load D+L TL Deflection 0.1235" 0.9318" L/999+ 15.23' Even Spans D+L LL Deflection 0.0544" 0.6212" L/999+ 14.3' Even Spans L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 HomsteadNeilXata - Level 10 10-17-17 4:06pm 2 of 2 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcA6 Member Type: Joist Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PSF Deck Connection: Glued & Nailed Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Other Start End Dead Start End Category Replacement Uniform (PSF) Top 10' 9.75" 24' 0.00" 0 10 Live Replacement Uniform (PSF) Top 0' 0.00" 10' 9.75" 20 10 Live Point (PLF) Top 0' 4.63" 1 239 Live Point (PLF) Top 0' 4.63" 525 0 Snow Point (PLF) Top 23' 7.38" 1 159 Live Point (PLF) Top 23' 7.38" 525 0 Snow 1 2 3 10 9 12 13 2 4 24 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 1066# -- 2 10' 9.750" Wall SPF Plate (425psi) N/A 3.500" 363# -- 3 24' 0.000" Wall SPF Plate (425psi) N/A 1.500" 979# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 125#(94plf) 700#(525plf) 366#(274plf) 2 167#(126plf) 0#(0plf) 195#(146plf) 3 -10#(-7plf) 700#(525plf) 279#(209plf) Design spans 10' 5.125" 12' 9.625" Product: 9-1/2" AJS 20 16.0" O.C.PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 364.'# 3395.'# 10% 4.56' Total Load D+L Negative Moment 395.'# 3395.'# 11% 10.81' Total Load D+L Shear 246.# 1160.# 21% 10.8' Total Load D+L End Reaction 171.# 1175.# 14% 0' Total Load D+L Int. Reaction 363.# 2350.# 15% 10.81' Total Load D+L TL Deflection 0.0266" 0.5214" L/999+ 5.08' Total Load D+L LL Deflection 0.0227" 0.3476" L/999+ 5.6' Total Load L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table