Loading...
CS 2nd floor GirderCalcsCS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 HomsteadNeilXata - Level 8 10-17-17 4:14pm 1 of 12 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG4 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 3' 1.00" -188 202 Live Replacement Uniform (PLF) Top 0' 0.00" 3' 1.00" 525 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 6' 8.75" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 6' 8.75" 0 13 Snow Replacement Uniform (PLF) Top 3' 1.00" 4' 8.00" -254 120 Live Replacement Uniform (PLF) Top 3' 1.00" 4' 8.00" 525 0 Snow Replacement Uniform (PLF) Top 4' 8.00" 5' 1.50" -254 120 Live Replacement Uniform (PLF) Top 4' 8.00" 5' 1.50" 525 0 Snow Replacement Uniform (PLF) Top 5' 1.50" 6' 8.75" -255 -120 Live Point (LBS) Top 0' 4.63" 0 1 Live Point (LBS) Top 0' 4.63" 0 39 Live Point (LBS) Top 0' 4.63" 133 0 Snow 1 2 6 8 12 6 8 12 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 2.942" 2188# -288# 2 6' 8.750" Wall SPF Plate (425psi) N/A 1.574" 1171# -760# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 -777# 1631# 557# 2 -876# 990# 181# Design spans 5' 11.500" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 289lbs at bearing 1 and ensure that the structure can resist appropriately. Review gravity uplift reaction force of 761lbs at bearing 2 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2770.'# 12233.'# 22% 3.09' Total Load D+S Negative Moment 741.'# 10637.'# 6% 3.96' Total Load D+L Shear 1292.# 4541.# 28% 5.12' Total Load D+S TL Deflection 0.0355" 0.2979" L/999+ 3.36' Total Load D+S LL Deflection 0.0275" 0.1986" L/999+ 3.36' Total Load S Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 HomsteadNeilXata - Level 8 10-17-17 4:14pm 2 of 12 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG5 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 12.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 0' 8.50" 207 69 Live Replacement Uniform (PLF) Top 0' 0.00" 4' 9.00" 179 60 Live Replacement Uniform (PLF) Top 0' 8.50" 1' 9.00" 207 69 Live Replacement Uniform (PLF) Top 1' 9.00" 4' 9.00" 207 69 Live 1 2 4 9 0 4 9 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 1103# -- 2 4' 9.000" Wall SPF Plate (425psi) N/A 1.500" 1103# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 809# 295# 2 809# 295# Design spans 4' 2.250" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1155.'# 21275.'# 5% 2.48' Total Load D+L Shear 582.# 7897.# 7% 3.74' Total Load D+L TL Deflection 0.0037" 0.2094" L/999+ 2.48' Total Load D+L LL Deflection 0.0027" 0.1396" L/999+ 2.48' Total Load L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 HomsteadNeilXata - Level 8 10-17-17 4:14pm 3 of 12 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG6 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 12.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 4' 0.50" 207 69 Live Replacement Uniform (PLF) Top 0' 0.00" 4' 9.00" 179 60 Live Replacement Uniform (PLF) Top 4' 0.50" 4' 9.00" 207 69 Live 1 2 4 9 0 4 9 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 1103# -- 2 4' 9.000" Wall SPF Plate (425psi) N/A 1.500" 1103# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 809# 295# 2 809# 295# Design spans 4' 2.250" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1155.'# 21275.'# 5% 2.27' Total Load D+L Shear 582.# 7897.# 7% 0.19' Total Load D+L TL Deflection 0.0037" 0.2094" L/999+ 2.27' Total Load D+L LL Deflection 0.0027" 0.1396" L/999+ 2.27' Total Load L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 HomsteadNeilXata - Level 8 10-17-17 4:14pm 4 of 12 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG7 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 12.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 11' 0.25" 130 208 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 5.75" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 5.75" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 5.75" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 5.75" 40 13 Live Point (LBS) Top 0' 5.50" 141 35 Live Point (LBS) Top 0' 5.50" 347 747 Snow 1 2 14 5 12 14 5 12 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 2.709" 4030# -- 2 14' 5.750" Wall SPF Plate (425psi) N/A 1.547" 2300# -373# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1629# 347# 2401# 2 1177# 0# 1123# Design spans 13' 8.500" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 374lbs at bearing 2 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 10248.'# 21275.'# 48% 7.24' Total Load D+L Negative Moment 1282.'# 21275.'# 6% 7.24' Total Load D+L Shear 2641.# 7897.# 33% 0.4' Total Load D+L TL Deflection 0.3504" 0.6854" L/469 7.24' Total Load D+L LL Deflection 0.1695" 0.4569" L/970 7.24' Total Load L Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 HomsteadNeilXata - Level 8 10-17-17 4:14pm 5 of 12 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG8 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 12.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 2' 4.69" 87 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 2' 4.69" 250 267 Live Replacement Uniform (PLF) Top 2' 4.69" 3' 6.00" 87 0 Snow Replacement Uniform (PLF) Top 2' 4.69" 3' 6.00" 214 258 Live Replacement Uniform (PLF) Top 3' 6.00" 6' 6.00" 87 0 Snow Replacement Uniform (PLF) Top 3' 6.00" 6' 6.00" 182 242 Live Replacement Uniform (PLF) Top 6' 6.00" 10' 3.50" 87 0 Snow Replacement Uniform (PLF) Top 6' 6.00" 10' 3.50" 207 256 Live Replacement Uniform (PLF) Top 10' 3.50" 11' 4.00" 87 0 Snow Replacement Uniform (PLF) Top 10' 3.50" 11' 4.00" 243 265 Live 1 2 11 4 0 11 4 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.758" 2615# -- 2 11' 4.000" Wall SPF Plate (425psi) N/A 1.721" 2559# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1142# 458# 1415# 2 1086# 458# 1401# Design spans 10' 6.750" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 6438.'# 21275.'# 30% 5.46' Total Load D+L Shear 2034.# 7897.# 25% 0.19' Total Load D+L TL Deflection 0.1374" 0.5281" L/922 5.46' Total Load D+0.75(L+S) LL Deflection 0.0619" 0.3521" L/999+ 5.46' Total Load 0.75(L+S) Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 HomsteadNeilXata - Level 8 10-17-17 4:14pm 6 of 12 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG9 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 12' 2.13" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 12' 3.00" 27 7 Live Replacement Uniform (PLF) Top 12' 2.13" 12' 3.00" 27 7 Live 1 2 12 3 0 12 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Girder SPF Plate (425psi) N/A N/A 420# -- 2 12' 3.000" Wall SPF Plate (425psi) N/A 1.500" 420# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 309# 112# 2 309# 112# Design spans 11' 6.875" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1217.'# 10637.'# 11% 6.08' Total Load D+L Shear 349.# 3948.# 8% 11.29' Total Load D+L TL Deflection 0.0600" 0.5786" L/999+ 6.08' Total Load D+L LL Deflection 0.0441" 0.3858" L/999+ 6.08' Total Load L Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 HomsteadNeilXata - Level 8 10-17-17 4:14pm 7 of 12 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG10 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 12' 3.00" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 12' 3.00" 40 13 Live Replacement Uniform (PLF) Top 12' 2.13" 12' 3.00" 27 7 Live Replacement Uniform (PLF) Top 12' 2.13" 12' 3.00" 27 7 Live 1 2 12 3 0 12 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Girder SPF Plate (425psi) N/A N/A 344# -349# 2 12' 3.000" Wall SPF Plate (425psi) N/A 1.500" 344# -349# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 -308# 112# 2 -308# 112# Design spans 11' 6.875" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 350lbs at bearing 1 and ensure that the structure can resist appropriately. Review gravity uplift reaction force of 350lbs at bearing 2 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 995.'# 10637.'# 9% 6.08' Total Load D+L Negative Moment 1014.'# 10637.'# 9% 6.08' Total Load D+L Shear 291.# 3948.# 7% 11.29' Total Load D+L TL Deflection -0.0500" 0.5786" L/999+ 6.08' Total Load D+L LL Deflection -0.0441" 0.3858" L/999+ 6.08' Total Load L Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 HomsteadNeilXata - Level 8 10-17-17 4:14pm 8 of 12 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG13 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 12.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 4' 10.50" 229 76 Live Replacement Uniform (PLF) Top 4' 10.50" 5' 7.00" 516 0 Snow Replacement Uniform (PLF) Top 4' 10.50" 5' 7.00" 251 386 Live Point (LBS) Top 4' 10.50" 69 767 Live Point (LBS) Top 4' 10.50" 1619 0 Snow Point (LBS) Top 5' 2.38" 0 24 Live Point (LBS) Top 5' 2.38" 0 69 Live Point (LBS) Top 5' 2.38" 237 0 Snow 1 2 5 7 0 5 7 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 852# -- 2 5' 7.000" Wall SPF Plate (425psi) N/A 2.049" 3047# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 579# 109# 273# 2 646# 1913# 1128# Design spans 5' 0.250" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1146.'# 21275.'# 5% 2.94' Total Load D+L Shear 920.# 9081.# 10% 4.89' Total Load D+0.75(L+S) TL Deflection 0.0057" 0.2510" L/999+ 2.69' Total Load D+0.75(L+S) LL Deflection 0.0037" 0.1674" L/999+ 2.69' Total Load 0.75(L+S) Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 HomsteadNeilXata - Level 8 10-17-17 4:14pm 9 of 12 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG17 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 12.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 1' 4.00" -9 292 Live Replacement Uniform (PLF) Top 0' 0.00" 1' 4.00" 525 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 11' 5.00" 6 1 Live Replacement Uniform (PLF) Top 0' 0.00" 11' 5.00" 27 7 Live Replacement Uniform (PLF) Top 9' 6.00" 11' 5.00" -3 260 Live Replacement Uniform (PLF) Top 9' 6.00" 11' 5.00" 525 0 Snow Point (LBS) Top 0' 7.13" 25 6 Live Point (LBS) Top 0' 7.13" 186 401 Snow Point (LBS) Top 1' 4.00" -25 587 Live Point (LBS) Top 1' 4.00" 1472 0 Snow Point (LBS) Top 7' 4.00" -49 1250 Live Point (LBS) Top 7' 4.00" 2918 0 Snow 1 2 11 5 0 11 5 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 3.254" 4840# -- 2 11' 5.000" Wall SPF Plate (425psi) N/A 2.799" 4164# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 151# 3076# 1764# 2 136# 2802# 1362# Design spans 10' 7.750" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 11964.'# 24466.'# 48% 7.33' Total Load D+S Shear 3367.# 9081.# 37% 10.71' Total Load D+S TL Deflection 0.2100" 0.5323" L/608 6.45' Total Load D+S LL Deflection 0.1426" 0.3549" L/896 6.45' Total Load S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 HomsteadNeilXata - Level 8 10-17-17 4:14pm 10 of 12 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG18 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 12.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 11' 4.13" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 11' 4.13" 6 1 Live Replacement Uniform (PLF) Top 0' 0.00" 11' 4.13" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 11' 4.13" 40 13 Live Replacement Uniform (PLF) Top 9' 9.00" 11' 4.13" 1 240 Live Replacement Uniform (PLF) Top 9' 9.00" 11' 4.13" 525 0 Snow Point (LBS) Top 9' 9.00" 7 951 Live Point (LBS) Top 9' 9.00" 2888 0 Snow 1 2 11 6 0 11 6 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 1001# -303# 2 11' 6.000" Wall SPF Plate (425psi) N/A 3.094" 4602# -303# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 405# 465# 348# 2 411# 3247# 1355# Design spans 11' 1.750" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Minimum 3.09" bearing required at bearing # 2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 304lbs at bearing 1 and ensure that the structure can resist appropriately. Review gravity uplift reaction force of 303lbs at bearing 2 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 6246.'# 24466.'# 25% 9.75' Total Load D+S Negative Moment 847.'# 21275.'# 3% 5.75' Total Load D+L Shear 3812.# 9081.# 41% 10.77' Total Load D+S TL Deflection 0.1087" 0.5573" L/999+ 6.31' Total Load D+0.75(L+S) LL Deflection 0.0724" 0.3715" L/999+ 6.31' Total Load 0.75(L+S) Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 HomsteadNeilXata - Level 8 10-17-17 4:14pm 11 of 12 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG24 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 12.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 4' 6.00" 179 60 Live Replacement Uniform (PLF) Top 0' 0.00" 4' 10.00" 6 1 Live Replacement Uniform (PLF) Top 0' 0.00" 24' 0.00" 27 7 Live Replacement Uniform (PLF) Top 4' 6.00" 4' 10.00" 156 41 Live Replacement Uniform (PLF) Top 4' 10.00" 16' 6.00" 6 1 Live Replacement Uniform (PLF) Top 16' 6.00" 19' 6.00" 156 41 Live Replacement Uniform (PLF) Top 16' 6.00" 24' 0.00" 6 1 Live Replacement Uniform (PLF) Top 19' 6.00" 24' 0.00" 179 60 Live Point (LBS) Top 0' 4.63" -117 377 Live Point (LBS) Top 0' 4.63" 1006 155 Snow Point (LBS) Top 4' 11.75" 0 84 Live Point (LBS) Top 4' 11.75" 597 577 Live Point (LBS) Top 16' 6.88" 0 84 Live Point (LBS) Top 23' 7.38" 44 7 Snow Point (LBS) Top 23' 7.38" 1 136 Live Point (LBS) Top 23' 7.38" 448 69 Snow Point (LBS) Top 23' 7.38" 46 485 Live Point (LBS) Top 23' 7.38" 1083 167 Snow 1 2 3 4 10 0 19 2 0 24 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 1399# -335# 2 4' 10.000" Wall SPF Plate (425psi) N/A 2.608" 3879# -- 3 24' 0.000" Wall SPF Plate (425psi) N/A 2.292" 3410# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 -727# 1006# 393# 2 2371# 0# 1508# 3 1193# 1575# 1334# Design spans 4' 5.375" 18' 9.375" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 335lbs at bearing 1 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 4524.'# 21275.'# 21% 17.98' Even Spans D+L Negative Moment 4227.'# 21275.'# 19% 4.83' Total Load D+L Shear 1327.# 7897.# 16% 22.68' Even Spans D+L TL Deflection 0.2080" 0.9391" L/999+ 16.1' Even Spans D+L LL Deflection 0.1413" 0.6260" L/999+ 16.1' Even Spans L CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 HomsteadNeilXata - Level 8 10-17-17 4:14pm 12 of 12 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives