Loading...
Stamped Calcs 12-03-15 w labelsCS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 FerrariSteveMcDonough111015 -12- 2-15 7:43am 1 of 2 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB13 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 9.4 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 6' 1.50" 282 71 Live Replacement Uniform (PLF) Top 0' 0.00" 12' 2.69" 271 68 Live Replacement Uniform (PLF) Top 6' 1.50" 12' 2.69" 697 266 Live Replacement Uniform (PLF) Top 12' 2.69" 12' 7.06" 504 194 Live Replacement Uniform (PLF) Top 12' 7.06" 15' 7.50" 504 194 Live Replacement Uniform (PLF) Top 15' 7.50" 15' 10.00" 27 7 Live Replacement Uniform (PLF) Top 15' 7.50" 15' 10.00" 27 7 Live Point (LBS) Top 0' 7.13" 349 0 Snow Point (LBS) Top 0' 7.13" 2121 2006 Live Point (LBS) Top 0' 7.13" -180 212 Snow Point (LBS) Top 0' 7.13" 34 8 Live Point (LBS) Top 0' 7.13" 63 147 Snow Point (LBS) Top 0' 7.13" 622 351 Live Point (LBS) Top 6' 1.50" 1202 441 Live Point (LBS) Top 12' 0.94" 26 53 Live Point (LBS) Top 12' 0.94" 226 548 Live Point (LBS) Top 15' 7.50" 3785 1255 Live 1 2 3 7 3 8 8 4 0 0 2 8 15 10 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 5.061" 7529# -- 2 7' 3.500" Wall SPF Plate (425psi) N/A 8.130" 12093# -- 3 15' 7.500" Wall SPF Plate (425psi) N/A 5.762" 8572# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 4589# 232# 2939# 2 8761# 0# 3332# 3 6217# 0# 2354# Design spans 6' 8.375" 8' 4.000" 0' 2.500" (right cant) Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Minimum 8.13" bearing required at bearing # 2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 8011.# 13958.# 57% 12.07' Even Spans D+L Negative Moment 8659.# 13958.# 62% 7.29' Adjacent 1 D+L Shear 5408.# 6317.# 85% 7.3' Adjacent 1 D+L TL Deflection 0.1721" 0.4167" L/581 11.88' Even Spans D+L LL Deflection 0.1218" 0.2778" L/821 11.46' Even Spans L CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 FerrariSteveMcDonough111015 -12- 2-15 7:43am 2 of 2 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Actual Allowable Capacity Location Loading TL Defl., Rt. -0.0144" 0.2000" 2L/347 15.83' Even Spans D+L LL Defl., Rt. -0.0100" 0.2000" 2L/498 15.83' Even Spans L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 FerrariSteveMcDonough111015 -12- 2-15 7:46am 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG1 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.1 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 3' 2.00" 244 61 Live Replacement Uniform (PLF) Top 0' 0.00" 13' 9.50" 27 7 Live Replacement Uniform (PLF) Top 3' 2.00" 11' 3.00" 314 79 Live Replacement Uniform (PLF) Top 11' 3.00" 13' 9.50" 314 79 Live Point (LBS) Top 0' 4.63" 210 341 Live Point (LBS) Top 0' 4.63" 531 81 Snow Point (LBS) Top 0' 4.63" 3440 0 Snow Point (LBS) Top 0' 4.63" 1490 2440 Live Point (LBS) Top 13' 5.88" 0 21 Live Point (LBS) Top 13' 5.88" 145 79 Live Point (LBS) Top 13' 5.88" 1675 630 Live 1 2 13 9 8 13 9 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.779" 9248# -- 2 13' 9.500" Wall SPF Plate (425psi) N/A 1.908" 5388# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 3760# 3971# 3450# 2 4033# 0# 1356# Design spans 13' 1.250" Product: 1-3/4x11-1/4 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 9214.# 19210.# 47% 6.94' Total Load D+L Shear 2429.# 7481.# 32% 12.83' Total Load D+L TL Deflection 0.3419" 0.6552" L/459 6.94' Total Load D+L LL Deflection 0.2664" 0.4368" L/590 6.94' Total Load L Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 FerrariSteveMcDonough111015 -12- 2-15 7:39am 1 of 3 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG1 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 16.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 3' 5.13" 2 185 Live Replacement Uniform (PLF) Top 0' 0.00" 3' 5.13" 508 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 12' 5.13" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 12' 5.13" 9 2 Live Replacement Uniform (PLF) Top 0' 0.00" 12' 5.13" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 12' 5.13" 40 13 Live Replacement Uniform (PLF) Top 0' 0.00" 12' 5.13" 0 81 Live Replacement Uniform (PLF) Top 3' 5.13" 12' 5.13" 2 199 Live Replacement Uniform (PLF) Top 3' 5.13" 12' 5.13" 554 0 Snow Point (LBS) Top 3' 5.13" 0 93 Live Point (LBS) Top 3' 5.13" 178 0 Snow Point (LBS) Top 8' 5.13" 0 92 Live Point (LBS) Top 8' 5.13" 177 0 Snow Point (LBS) Top 12' 0.50" 92 125 Snow Point (LBS) Top 12' 0.50" 47 13 Snow 1 2 12 5 2 12 5 2 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 2.338" 5216# -290# 2 12' 5.125" Wall SPF Plate (425psi) N/A 2.387" 5602# -152# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 450# 3296# 1921# 2 450# 3520# 2081# Design spans 11' 8.125" Product: 1-3/4x11-1/4 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 290lbs at bearing 1 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 15628.# 34462.# 45% 6.2' Total Load D+S Negative Moment 849.# 29967.# 2% 6.2' Total Load D+L Shear 4508.# 12905.# 34% 11.46' Total Load D+S TL Deflection 0.3087" 0.5839" L/453 6.2' Total Load D+S LL Deflection 0.1959" 0.3892" L/715 6.2' Total Load S CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 FerrariSteveMcDonough111015 -12- 2-15 7:39am 2 of 3 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 FerrariSteveMcDonough111015 -12- 2-15 7:39am 3 of 3 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG5 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.1 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 8' 9.13" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 8' 9.13" 27 7 Live Point (LBS) Top 7' 5.50" 15 2287 Live Point (LBS) Top 7' 5.50" 5312 0 Snow 1 2 8 9 2 8 9 2 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 984# -- 2 8' 9.125" Wall SPF Plate (425psi) N/A 4.590" 6828# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 220# 609# 362# 2 231# 4703# 2125# Design spans 8' 2.125" Product: 1-3/4x11-1/4 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 6390.# 22091.# 28% 7.46' Total Load D+S Shear 6805.# 8603.# 79% 7.47' Total Load D+S TL Deflection 0.0651" 0.4089" L/999+ 4.72' Total Load D+S LL Deflection 0.0435" 0.2726" L/999+ 4.72' Total Load S Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 FerrariSteveMcDonough111015 -12- 2-15 7:42am 1 of 2 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB20 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 13.8 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 3' 11.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 4' 9.50" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 4' 9.50" 27 13 Live Replacement Uniform (PLF) Top 0' 0.00" 5' 2.50" 79 24 Snow Replacement Uniform (PLF) Top 0' 0.00" 23' 9.50" 9 2 Live Replacement Uniform (PLF) Top 3' 11.00" 4' 8.00" 27 7 Live Replacement Uniform (PLF) Top 4' 8.00" 23' 9.50" 27 7 Live Replacement Uniform (PLF) Top 5' 2.50" 21' 2.50" 79 24 Snow Replacement Uniform (PLF) Top 19' 5.50" 23' 9.50" -53 -13 Live Replacement Uniform (PLF) Top 19' 5.50" 23' 9.50" 27 13 Live Replacement Uniform (PLF) Top 21' 2.50" 23' 9.50" 79 24 Snow Point (LBS) Top 0' 0.63" 35 10 Snow Point (LBS) Top 0' 4.25" 0 2 Live Point (LBS) Top 0' 4.25" 1 114 Live Point (LBS) Top 0' 4.25" 303 0 Snow Point (LBS) Top 12' 1.50" 2 163 Live Point (LBS) Top 12' 1.50" 840 0 Snow Point (LBS) Top 13' 2.50" 938 0 Snow Point (LBS) Top 13' 2.50" 1792 843 Live Point (LBS) Top 23' 8.88" 1 115 Live Point (LBS) Top 23' 8.88" 303 0 Snow Point (LBS) Top 23' 8.88" 35 10 Snow 1 2 3 4 0 4 4 4 10 4 16 0 0 2 7 0 23 9 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 4.250" Wall SPF Plate (425psi) N/A 1.500" 372# -1187# 2 5' 2.500" Wall SPF Plate (425psi) N/A 3.344" 4975# -- 3 21' 2.500" Wall SPF Plate (425psi) N/A 4.717" 7017# -- 4 23' 9.500" Wall SPF Plate (425psi) N/A 1.500" 357# -3342# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 -697# -544# -254# 2 1998# 2630# 1504# 3 3017# 3521# 2113# 4 -1655# -1571# -933# Design spans 0' 3.625" (left cant) 4' 10.250" 16' 0.000" 2' 6.375" CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 FerrariSteveMcDonough111015 -12- 2-15 7:42am 2 of 2 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Product: 1-3/4x14 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Minimum 3.34" bearing required at bearing # 2 Minimum 4.72" bearing required at bearing # 3 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 1187lbs at bearing 1 and ensure that the structure can resist appropriately. Review gravity uplift reaction force of 3343lbs at bearing 4 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 9707.# 33390.# 29% 13.21' Odd Spans D+0.75(L+S) Negative Moment 9630.# 33390.# 28% 21.21' Adjacent 3 D+0.75(L+S) Shear 3821.# 10706.# 35% 21.22' Adjacent 3 D+0.75(L+S) TL Deflection 0.1539" 0.8000" L/999+ 13.2' Odd Spans D+0.75(L+S) LL Deflection 0.1093" 0.5333" L/999+ 13.2' Odd Spans 0.75(L+S) TL Defl., Lt. 0.0021" 0.2000" 2L/999+ 0' Odd Spans D+0.75(L+S) LL Defl., Lt. 0.0015" 0.2000" 2L/999+ 0' Odd Spans 0.75(L+S) Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 FerrariSteveMcDonough111015 -12- 2-15 7:41am 1 of 4 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB8 Member Type: Beam Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 17.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 1' 4.50" 67 21 Snow Replacement Uniform (PLF) Top 0' 0.00" 17' 8.50" 0 81 Live Replacement Uniform (PLF) Top 1' 4.50" 5' 4.50" 0 30 Live Replacement Uniform (PLF) Top 1' 4.50" 6' 2.75" 105 0 Snow Replacement Uniform (PLF) Top 5' 4.50" 12' 5.75" 0 43 Live Replacement Uniform (PLF) Top 6' 2.75" 11' 5.75" 143 0 Snow Replacement Uniform (PLF) Top 11' 5.75" 16' 5.75" 104 0 Snow Replacement Uniform (PLF) Top 12' 5.75" 16' 5.75" 0 30 Live Replacement Uniform (PLF) Top 16' 5.75" 17' 8.50" 67 20 Snow Point (LBS) Top 0' 4.63" 1 129 Live Point (LBS) Top 0' 4.63" 238 0 Snow Point (LBS) Top 17' 3.88" 1 128 Live Point (LBS) Top 17' 3.88" 235 0 Snow 1 2 17 8 8 17 8 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 2442# -- 2 17' 8.500" Wall SPF Plate (425psi) N/A 1.500" 2439# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 3# 1188# 1254# 2 3# 1186# 1253# Design spans 16' 11.250" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 9361.# 38167.# 24% 8.85' Total Load D+S Shear 1892.# 13622.# 13% 0.4' Total Load D+S TL Deflection 0.3266" 0.8469" L/622 8.85' Total Load D+S LL Deflection 0.1543" 0.5646" L/999+ 8.85' Total Load S Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 FerrariSteveMcDonough111015 -12- 2-15 7:41am 2 of 4 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB13 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.1 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 3' 2.00" 183 61 Live Replacement Uniform (PLF) Top 0' 0.00" 11' 3.00" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 11' 3.00" 40 13 Live Replacement Uniform (PLF) Top 0' 0.00" 13' 9.00" 27 7 Live Replacement Uniform (PLF) Top 3' 2.00" 11' 3.00" 236 79 Live Replacement Uniform (PLF) Top 11' 3.00" 13' 9.00" 268 79 Live Point (LBS) Top 0' 4.63" 10 1853 Live Point (LBS) Top 0' 4.63" 3440 0 Snow Point (LBS) Top 0' 4.63" -23 -7 Snow Point (LBS) Top 0' 4.63" -18 -5 Snow Point (LBS) Top 0' 4.63" 0 81 Live Point (LBS) Top 0' 4.63" 0 81 Live Point (LBS) Top 0' 4.63" 2 191 Live Point (LBS) Top 0' 4.63" 2 191 Live Point (LBS) Top 0' 4.63" 531 0 Snow Point (LBS) Top 0' 4.63" 531 0 Snow 1 2 13 9 0 13 9 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 5.278" 7850# -- 2 13' 9.000" Wall SPF Plate (425psi) N/A 1.778" 2644# -225# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1868# 4460# 3061# 2 1956# 0# 688# Design spans 13' 1.750" Product: 1-3/4x11-1/4 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 8738.# 19210.# 45% 6.96' Total Load D+L Negative Moment 1111.# 19210.# 5% 6.96' Total Load D+L Shear 2278.# 7481.# 30% 12.87' Total Load D+L TL Deflection 0.3263" 0.6573" L/483 6.96' Total Load D+L LL Deflection 0.2397" 0.4382" L/658 6.96' Total Load L Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 FerrariSteveMcDonough111015 -12- 2-15 7:41am 3 of 4 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB15 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 14.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 6' 9.50" 198 55 Live Replacement Uniform (PLF) Top 0' 0.00" 6' 9.50" 245 65 Live Replacement Uniform (PLF) Top 6' 9.50" 10' 11.00" 171 43 Live Replacement Uniform (PLF) Top 6' 9.50" 22' 11.13" 218 55 Live Replacement Uniform (PLF) Top 10' 11.00" 18' 2.75" 186 46 Live Replacement Uniform (PLF) Top 18' 2.75" 22' 11.13" 155 37 Live Replacement Uniform (PLF) Top 22' 11.13" 23' 0.00" 27 7 Live Replacement Uniform (PLF) Top 22' 11.13" 23' 0.00" 27 7 Live Point (LBS) Top 6' 7.75" 173 456 Snow Point (LBS) Top 6' 7.75" 13 2045 Live Point (LBS) Top 6' 7.75" 4614 0 Snow Point (LBS) Top 22' 7.38" 93 29 Snow 1 2 3 9 0 0 14 0 0 23 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 2878# -- 2 9' 0.000" Wall SPF Plate (425psi) N/A 5.017" 11194# -- 3 23' 0.000" Wall SPF Plate (425psi) N/A 1.500" 2742# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1717# 990# 848# 2 5882# 3998# 3784# 3 2222# -107# 521# Design spans 8' 7.375" 13' 7.375" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 8882.# 25040.# 35% 6.65' Total Load D+S Negative Moment 10697.# 21774.# 49% 9' Total Load D+L Shear 7274.# 10898.# 66% 8.57' Total Load D+0.75(L+S) TL Deflection 0.2847" 0.6807" L/573 16.49' Even Spans D+L LL Deflection 0.2594" 0.4538" L/629 16.49' Even Spans L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 FerrariSteveMcDonough111015 -12- 2-15 7:47am 1 of 2 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG11 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.7 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 6' 6.00" 1 78 Live Replacement Uniform (PLF) Top 0' 0.00" 6' 6.00" 1 78 Live Replacement Uniform (PLF) Top 0' 0.00" 6' 6.00" 209 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 6' 6.00" 209 0 Snow Replacement Uniform (PLF) Top 6' 6.00" 6' 8.75" 1 63 Live Replacement Uniform (PLF) Top 6' 6.00" 6' 8.75" 209 0 Snow Replacement Uniform (PLF) Top 6' 6.00" 16' 6.00" 0 6 Live Replacement Uniform (PLF) Top 6' 6.00" 16' 6.00" 16 0 Snow Replacement Uniform (PLF) Top 6' 8.75" 23' 0.00" 1 63 Live Replacement Uniform (PLF) Top 6' 8.75" 23' 0.00" 209 0 Snow Replacement Uniform (PLF) Top 16' 6.00" 23' 0.00" 1 78 Live Replacement Uniform (PLF) Top 16' 6.00" 23' 0.00" 209 0 Snow Replacement Uniform (PLF) Top 23' 0.00" 29' 9.50" 0 34 Live Replacement Uniform (PLF) Top 23' 0.00" 29' 9.50" 1 78 Live Replacement Uniform (PLF) Top 23' 0.00" 29' 9.50" 96 0 Snow Replacement Uniform (PLF) Top 23' 0.00" 29' 9.50" 209 0 Snow Point (LBS) Top 6' 4.25" 2 424 Live Point (LBS) Top 6' 4.25" 685 0 Snow Point (LBS) Top 16' 7.75" 2 424 Live Point (LBS) Top 16' 7.75" 685 0 Snow 1 2 3 4 6 6 0 16 6 0 6 9 8 29 9 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 366# -- 2 6' 6.000" Wall SPF Plate (425psi) N/A 4.323" 7539# -- 3 23' 0.000" Wall SPF Plate (425psi) N/A 5.129" 7630# -- 4 29' 9.500" Wall SPF Plate (425psi) N/A 1.500" -- -199# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1# 261# 105# 2 15# 5293# 2246# 3 16# 5440# 2190# 4 0# -140# -59# Design spans 6' 1.375" 16' 6.000" 6' 4.875" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 FerrariSteveMcDonough111015 -12- 2-15 7:47am 2 of 2 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 8072.# 24466.# 32% 16.65' Total Load D+S Negative Moment 10100.# 24466.# 41% 23' Total Load D+S Shear 4111.# 9081.# 45% 22.17' Total Load D+S TL Deflection 0.2780" 0.8250" L/712 15.57' Total Load D+S LL Deflection 0.1968" 0.5500" L/999+ 15.57' Total Load S Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table