15-053_CDH_Cafeteria_PERMIT_REVISED_coverCAFETERIA
NORTHAMPTON, MASSACHUSETTS 01061
30 LOCUST STREET
COOLEY DICKINSON HOSPITAL
Renovation to:
INDEX TO DRAWINGS
TITLE SHEET
INFORMATION SHEET
DEMOLITION PLAN
EXISTING CONDITIONS OVERVIEW FLOOR PLAN
GENERAL NOTES
FLOOR PLAN
GI001
GI002
AD101
GC101
A101
THE GENERAL CONTRACTOR WILL PROVIDE BARRICADES, TEMPORARY LIGHTS, TEMPORARY TELEPHONE SERVICE, AND CLEAN-UP SERVICE TO THE WORK AREA.
THE GENERAL CONTRACTOR WILL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE PRIOR TO PROCEEDING WITH THE WORK. THE GENERAL CONTRACTOR WILL COORDINATE WORK ACCORDINGLY
WITH ALL SUBCONTRACTORS AND THE OWNER.
THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE AND THOROUGH CLEAN-UP AT THE END OF THE JOB, AND FOR DAILY REMOVAL OF CONSTRUCTION DEBRIS AND CLEAN-UP.
THE GENERAL CONTRACTOR WILL PERFORM MINOR SPACKLING AND REPAIRS TO EXISTING WALLS THROUGHOUT THE WORK AREA, AS IS REQUIRED IN PREPARATION FOR NEW FINISHES.
IT WILL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY AND EXECUTE ALL WORK IN ACCORDANCE WITH THE MASSACHUSETTS BUILDING CODE, 8TH EDITION, WITH ALL OF ITS REFERENCED
PUBLICATIONS AND ALL OTHER APPLICABLE STATE, FEDERAL, AND LOCAL CODES AND REGULATIONS.
IT WILL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO SEE THAT ALL WORK PERFORMED IS IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION'S LIFE SAFETY CODE ( NFPA 101, 2012 ED.).
THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS APPLICABLE TO THE SCOPE OF WORK, AS REQUIRED BY THE
OWNER, AND AS REQUIRED FOR REGULATORY COMPLIANCE.
THE GENERAL CONTRACTOR WILL PROVIDE THE OWNER WITH INSURANCE CERTIFICATES FOR THE REQUIRED INSURANCES PRIOR TO STARTING THE WORK.
THE GENERAL CONTRACTOR WILL FILE FOR AND SECURE ALL APPROVALS, PERMITS, AND CERTIFICATES OF COMPLIANCE AS REQUIRED.
THE GENERAL CONTRACTOR SHALL FULLY COMPLY WITH THE OWNER'S "INTERIM LIFE SAFETY POLICY" DURING THE ENTIRE CONSTRUCTION PERIOD.
CONSTRUCTION CLASSIFICATION
OCCUPANCY CLASSIFICATION
APPLICABLE CODES & STANDARDS
BUILDING CODES AND STANDARDS
1. MASSACHUSETTS STATE BUILDING CODE (780 CMR), 8TH
EDITION
2. MASSACHUSETTS ELECTRIC CODE 2014
3. NFPA 101 LIFE SAFETY CODE (2015 EDITION)
4. MASSACHUSETTS ARCHITECTURAL ACCESS BOARD
REGULATORS (521 CMR)
5. MASSACHUSETTS STATE PLUMBING CODE (248 CMR)
ALTERNATES
A2 - ASSEMBLY
TYPE 2B
INTERIOR ELEVATIONSA201
DETAILSA501
DOOR & WINDOW SCHEDULESA601
ROOM FINISH SCHEDULEAF101
ELECTRICAL PLANE101
REFLECTED CEILING PLANA102
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR ALL WORK THAT IS SHOWN ON THE CONTRACT DRAWINGS THAT IS NOT SPECIFICALLY IDENTIFIED TO BE THAT OF A SUB-CONTRACTOR, INCLUDING ALL
WORK THAT IS DESCRIBED BY THE CONTRACT DOCUMENTS THAT IS NOT IDENTIFIED AS BEING ANY SPECIFIC CONTRACTOR'S RESPONSIBILITY. THE SCOPES OF WORK OF THE INDIVIDUAL FIELD
SUB-CONTRACTORS ARE IDENTIFIED IN THEIR RESPECTIVE SPECIFICATION SECTIONS.
A: A/C WINDOW UNIT TO BE REMOVED; REBUILD WINDOW SASH
B: NEW FURNITURE AND FINISHES TO MATCH IN CONFERENCE/ DINING ROOM C
C: (NOT USED)
D: REMOVE 1 2X2 LIGHT ABOVE SALAD BAR, INSTALL PENDANT LIGHTS
E: PAINT 2X2 CEILING TILES & GRID IN ACT SOFFIT (HORIZONTAL AND VERTICAL SURFACES) ALONG
NORTH WALL OF SERVING LINE
F: REPLACE ALL 2X2 LIGHTS IN ROOM #G-234
G: NEW GLASS DOORS & MANTLE FOR FIREPLACE
H: REPLACE ALL WOOD GRAIN LAMINATE ON STAINLESS STEEL EQUIPMENT IN SERVING LINE AREA WITH
L1
I: NEW TRIM FOR FIREPLACE
J: ELECTRIC INSERT FOR FIREPLACE TITLE SHEET
GI001
BW
SEAL:
MARK DATE ISSUE
-01/21/2016 USE GROUP CLASSIFICATION / OCCUPANCY LOAD
PROJECT NO:
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
DATE:
COPYRIGHT:
15-053
REK
REK
01/08/2016
SHEET TITLE:
CONSULTANT:
64 GOTHIC STREET, SUITE 1
NORTHAMPTON, MA 01060
T 413.585.1512 F 413.586.7945
www.haiarchitecture.com
H AI Architecture, Inc.
Cafeteria
Cooley Dickinson Hospital
30 Locust Street
Northampton, MA 01061
Renovation to:
PROJECT:
A B B R E V I A T I O N S
Z O N I N G A N A L Y S I S
ZONING DISTRICT:
HOSPITAL (SEE INTERNATIONAL BUILDING CODE TABLE 1004.1.1 & CHAPTER 300 "USE
AND OCCUPANCY") (EXISTING MIXED USE CONTAINS I2-HOSPITAL AND B-BUSINESS)
PRINCIPAL USE:
NOT APPLICABLEZONING RESTRICTIONS RELATIVE TO USE:
NOT APPLICABLE
PARKING REQUIREMENTS:
NOT APPLICABLE
ADDITIONAL REQUIREMENTS:
NOT APPLICABLE
G R A P H I C S Y M B O L S
INTERIOR ELEVATION DESIGNATION
DETAIL IDENTIFICATION
ELEVATION LETTER
SECTION DESIGNATION
ON SHEET WHERE SECTION IS TAKEN; SHEET NUMBER WHERE DRAWN
SECTION DESIGNATION ROOM AND NAME NUMBER
ON SHEET WHERE DETAIL IS TAKEN; SHEET NUMBER WHERE DRAWN
ON SHEET WHERE SECTION IS TAKEN; SHEET NUMBER WHERE DRAWN
DETAIL DESIGNATION
DOOR NUMBER
KEY NOTE
WALL TYPE
HEIGHT MARK
DETAIL DESIGNATION
ON SHEET WHERE DETAIL IS TAKEN; SHEET NUMBER WHERE DRAWN
DETAIL DESIGNATION
SECTION DESIGNATION
FIXTURE HEIGHTS
15"-48"MIN. MAX.17"-25"36" MAX.TO SPOUT OUTLET27" MIN.KNEE CLEARANCE48"MAX48"MAX.Per NFPA 72 the strobe shall be no less
than 80" and no greater than 96" AFF.
When clg heights don't allow for a min.
height of 80", strobes shall be mounted
within 6" of clg
17"
MIN.34" MAX.TO RIMINSULATE ALL PLUMBING
W/ TRUEBRO LAVATORY GUARD
OR EQUAL
FINISH FLOOR 15"-48"MIN MAX48"48"
LINE
FINISH FLOOR
LINE
13-1/2"
MIN.
FINISH FLOOR
LINE
The highest operable part of telephone,
including dial, handset and coin deposit slots
shall be within the reach ranges specified in
ABA Section 30815"MINAccessible storage spaces shall be within
at least one of the reach ranges specified
in ABA Sections 308 29"MIN.27"MIN.40" MAX. TO BTMEDGE OF REFLECTINGSURFACEMount on side wall closest to
water closet, can not be
mounted behind opposite bars
Grab bars shall be between 1-1/4" and
LQDQGORFDWHGD"FOU
from wall
HIGHEST
OPERABLE
PART
15" - 42" DEPENDENTON FORWARD OR SIDE REACH36"x48"
CLR. FLR.
SPACE
FIRE HORN AND LIGHT FIRE EXTINGUISHER
CABINET
PUBLIC TELEPHONE (ELEVATION)
30"x48" CLR. FLOOR SPACE
FOR FORWARD APPROACH
PUBLIC TELEPHONE
(PLAN)
CLOTHES HOOK/ROD DUPLEX RECEPTACLE
30"x48" CLR. FLOOR
SPACE
LAVATORY (ELEV.)LAVATORY FORWARD
APPROACH (PLAN)
MIRROR DRINKING FOUNTAIN
(PARALLEL APPROACH)
FREE STANDING OR
BUILT-IN UNITS
DRINKING FOUNTAIN
(FORWARD APPROACH)
WALL & POST MOUNTED
CANTILEVERED UNITS
ACCESSIBLE
DRINKING FOUNTAIN
(ELEV.)
TOILET PAPER
DISPENSER/HOLDER
TOILET CLOSEST SIDE WALL
GRAB BARS (ELEV.)
TOILET REAR WALL GRAB
BARS (ELEV.)
TOILET
(SIDE ELEV.)
Flush controls for water closets shall
be on the open side of water closet.
Operable parts shall be placed w/in
one of the reach ranges specified in
ABA section 308
TOILET (FRONT
ELEV.)
URINAL
(ELEV.)
URINAL
(PLAN)
MIN. SHOWER
CONFIGURATION PLAN
SOAP DISPENSER SANITARY NAPKIN - TAMPON
DISPENSER
PAPER TOWEL
DISPENSER20"MAX2'-0"MAX.80"-96" AFFFIRE ALARM
PULL STATION42"-48"OPTIONAL POST
OR BASE 4'-0"MAX.8"
MIN.30"x48" CLR.
FLOOR SPACE
30"x48" CLR.
FLOOR SPACE6" MAX.
TOE CLEARANCE
6" MAX.
TOE
CLEARANCE
15" - 42" DEPENDENTON FORWARD OR SIDE REACH15" - 42" DEPENDENTON FORWARD OR SIDE REACHNOTE: CONTROLS OF OPERATING MECHANISMS MUST BE PLACED WITHIN AT LEAST ONE OF THE REACH
RANGES SPECIFIED IN UFAS SECTION 4.2.5 & 4.2.6
HIGHEST
OPERABLE
PART
FOR FORWARDOR SIDE REACHFOR FORWARDAPPROACHFOR FORWARDAPPROACHSEE
PLAN
FORUNOBSTRUCTEDSIDE ORFORWARD REACHSIDE WALL
17" MAX.TO RIM44" TYP.FLUSH CONTROLSW/IN REACH RANGEABA SECTION 3089" MIN.TOECLEARANCE17"MIN.5"
MAX.
5"
MAX.
SPOUT
LOCATION SPOUT
LOCATION
15"
MIN.
15"
MIN.9" MIN.TOE CLEARANCE8" MIN.
KNEE CLEARANCE
CLEARANCE AT
TOILET (PLAN)
60"
MIN.56"MIN.MIRROR
18"
30"x48" CLR.
FLOOR SPACE
56"x60" MIN. CLR.
FLOOR SPACE
-REQUIRED CLEAR FLOOR SPACES, CLEARANCE AT FIXTURES AND TURNING SPACES
SHALL BE PERMITTED TO OVERLAP.
-DOOR SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED
FOR ANY FIXTURE. DOORS SHALL BE PERMITTED TO SWING INTO THE REQUIRED
TURNING SPACE.
1
A101
A
B
C
D 2
A102
1
A101
CONFERENCE
ROOM
1005
201
2
CEILING HEIGHT
EL. = 100'-0"
36
A101
EXIT REQUIREMENTS:
OCCUPANCY LOAD:
3,370 SF @ 15 SF / OCCUPANT = 224 OCCUPANTS (SEE INTERNATIONAL BUILDING CODE TABLE 1004.1.1)
MINIMUM EGRESS WIDTH CALCULATIONS (DOORS, RAMPS & CORRIDORS):
MINIMUM EGRESS WIDTH CALCULATIONS (STAIRS):
NOT APPLICABLE (SEE INTERNATIONAL BUILDING CODE 1009.1, NOT LESS THAN 44")
REQUIREMENTS FOR NUMBER OF WATER CLOSETS & LAVATORIES (USE GROUP A2):
2 EXITS REQUIRED; 2 EXITS PROVIDED (SEE INTERNATIONAL BUILDING CODE TABLE 1021.1)
DOORS: 44" MIN. REQUIRED, 60" PROVIDED AT STAIR AND CORRIDOR HORIZONTAL EGRESS (SEE INTERNATIONAL BUILDING
CODE 1005.1)
NOT APPLICABLE; NO CHANGE OF USE
C O D E A N A L Y S I S
RAMPS: NOT APPLICABLE (SEE INTERNATIONAL BUILDING CODE 1010.5)
CORRIDORS: 44" MIN. REQUIRED, 57" PROVIDED (SEE INTERNATIONAL BUILDING CODE 1018.2)33"-36"MIN. MAX.7"-9"
MIN. MAX.15"-48"MIN. MAX.12"
MAX.42"
MIN.
12"
MIN.33"-36"MIN. MAX.17"-19"MIN. MAX.36"
MIN.
24"
MIN.
OPENSIDE
54"
MIN.
TRANSFER
SIDE1'-6"33"-36"MIN. MAX.39"-41"
MIN. MAX.
EYE/FACE WASH
(SIDE ELEV.)27" MIN.KNEE CLEARANCE36" MAX.SPRAY HEADCLEARANCE48" MAX. HEIGHTFOR FORWARD REACH30"x48" CLR.
FLOOR SPACE
EYE/FACE WASH
(PLAN)
18"
PAPER TOWEL DISPENSER
AND WASTE RECEPTACLE4'-0"MAX.HIGHEST OPERABLEPARTFOLD DOWN SEAT
AS REQUIRED
AIR CONDITIONING
INSULATION
INTERIOR
LAMINATE
JOIST
JOINT
LAVATORY
JANITOR
INSIDE DIAMETER
JST.
JT.
LAM.
LAV.
JAN.
I.D.
INSUL.
INT.
W
W.C.
WD.
WATER CLOSET
WITH
WOOD
FACE OF FINISH
ELECTRIC WATER COOLER
FACE OF MASONRY
FACE OF STUD
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FIRE HOSE CABINET
FINISH
FLOOR
GYPSUM WALL BOARD
HANDICAPPED
GENERAL
GAUGE
GALVANIZED
GRADE
GENERAL CONTRACTOR
GLASS
GLAZE
HEIGHT
HOLLOW METAL
HOT WATER HEATER
HEATING, VENTILATING AND
EXHAUST
EXISTING
EXPANSION
EXTERIOR
EAST
EXPANSION JOINT
ELEVATION
ELECTRICAL
ELEVATOR
EQUAL
EQUIPMENT
EMERGENCY ROOM
DRINKING FOUNTAIN
DIAMETER
DIMENSION
DOWN
DOOR
DETAIL
DRAWINGS
CERAMIC TILE
FACE OF FOUNDATION WALL
F.D.
HGT.
H.M.
H.W.H.
HVAC
H.C.
GA.
GEN.
GALV.
G.C.
GL.
GRD.
G.W.B.
GLZ.
F.F.
F.O.M.
F.O.S.
FDN.
F.E.
F.E.C.
F.H.C.
FIN.
FLR.
F.O.F.
E.J.
E.W.C.
EX.
EXP.
EXT.
EXH.
EL.
ELEC.
ELEV.
EQ.
EQUIP.
E.R.
DIM.
DN
DR.
DTL.
DWGS.
E
DIA.
C.T.
D.F.
SUSPEND(ED)
STRUCTURALSTRUCT.
SUSP.
T.O.W.
UR.
V.B.
V.I.F.
VERT.
V.C.T.
VEST.
U.N.O.
U.O.D.
U.H.
T.O.S.
T.SLB.
THK.
TLT.
TYP.
T.O.F.
T.O.
TEL.
SYS.
TOP OF WALL ELEVATION
UNLESS NOTED OTHERWISE
VINYL COMPOSITION TILE
TOP OF STEEL ELEVATION
URINAL
VERIFY IN FIELD
VINYL BASE
VESTIBULE
VERTICAL
TOP OF SLAB
UNDERSIDE OF DECK
UNIT HEATER
TOP OF FOUNDATION
THICK
TYPICAL
TOILET
TOP OF
TELEPHONE
TEMPERED
SYSTEM
STOR.
STL.
S.S.
SPEC.
SIM.
SECT.
REQ'D
R.O.
RM.
RGH.
R.D.
REFR.
REF.
REINF.
SPECIFICATIONS
STAINLESS STEEL
STORAGE
STEEL
SECTION
SIMILAR
REQUIRED
ROUGH OPENING
ROOM
ROUGH
REFRIGERATOR
REINFORCE
ROOF DRAIN
REFERENCE
CLEAR (DIMENSION)
CABINET
CONTROL JOINT
CONCRETE
CONSTRUCTION
CONTINUOUS
CLOSET
CENTER
CEILING
CONCRETE MASONRY UNIT
COLUMN
COMPACTED (COMPOSITION)
CONTRACTOR
COL.
CONC.
CONST.
CONT.
COMP.
CONTR.
CLR.
CTR.
CLG.
CMU
CL.
C.J.
CAB.
PLYWD.
PTN.
PT.
PTD.
PVC
PLAM.
PLAS.
PBD.
P.L.
N.T.S.
OPP.
OPG.
O.F.C.I.
O.C.
N.D.
NEC.
N.I.C.
N
NAT.
PARTITION
POLYVINYL CHLORIDE
PLYWOOD
PAINTED
PAINT
PARTICLE BOARD
PROPERTY LINE
PLASTIC LAMINATE
PLASTER
NOT TO SCALE
OPPOSITE
ON CENTER
OWNER FINISHED,
OPENING
NECESSARY
NATURAL
NOT IN CONTRACT
NAPKIN DISPENSER
NORTH
M.E.P.
MISC.
MULL.
M.O.
MIN
MTL.
MFR.
MAS.
MAX.
MECH.
PLUMBING
MANUFACTURER
MISCELLANEOUS
MASONRY OPENING
MINERAL CORE
MULLION
METAL
MECHANICAL
MASONRY
MAXIMUM
EXTERIOR INSULATION & E.I.F.S.
FINISH SYSTEM
FIELD VERIFYF.V.
MTD.MOUNTED
CONTRACTOR INSTALLED
O.F.O.I.OWNER FINISHED,
OWNER INSTALLED
SF SQUARE FOOT
STD.STANDARD
MECHANICAL, ELECTRICAL,
INSULATED HOLLOW METALI.H.M.
S SOUTH
INSULATED STEELI.S.
TI
TEMPERED INSULATED
KICKPLATE (HEIGHT")K(12)
1/4 W.G.1/4" WIRE GLASS
1/4 T.1/4" TEMPERED GLASS
CORNER GUARDC.G.
EXISTING TO REMAINE.T.R.
S.M.SURFACE MOUNTED
ANCHOR BOLT
ACOUSTICAL
AIR CONDITIONER
ADJACENT
ABOVE FINISH FLOOR
ALTERNATE
ALUMINUM
ANCHOR
ANODIZED
ARCHITECT
B.L.
BD.
BLDG.
BLK.
BLKG.
B.O.
A.B.
ACOUST.
A.C.
ADJ.
A.F.F.
ALT.
ALUM.
ANCH.
ANOD.
ARCH.
BTM.
BRG.
BRK.
BUILDING LINE
BOARD
BUILDING
BLOCK
BLOCKING
BOTTOM OF
BOTTOM
BEARING
BRICK
WEST
S.C.W.SOLID CORE WOOD
MIN.MINIMUM
T.O.
T.
T.I.
U.C.REFR.UNDER COUNTER REFRIGERATOR
W/
WITHOUTW/O
WITHINW/IN
INFORMATION SHEET
GI002
BW
SEAL:
MARK DATE ISSUE
-01/21/2016 USE GROUP CLASSIFICATION / OCCUPANCY LOAD
PROJECT NO:
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
DATE:
COPYRIGHT:
15-053
REK
REK
01/08/2016
SHEET TITLE:
CONSULTANT:
64 GOTHIC STREET, SUITE 1
NORTHAMPTON, MA 01060
T 413.585.1512 F 413.586.7945
www.haiarchitecture.com
H AI Architecture, Inc.
Cafeteria
Cooley Dickinson Hospital
30 Locust Street
Northampton, MA 01061
Renovation to:
PROJECT: