Loading...
15-053_CDH_Cafeteria_PERMIT_REVISED_coverCAFETERIA NORTHAMPTON, MASSACHUSETTS 01061 30 LOCUST STREET COOLEY DICKINSON HOSPITAL Renovation to: INDEX TO DRAWINGS TITLE SHEET INFORMATION SHEET DEMOLITION PLAN EXISTING CONDITIONS OVERVIEW FLOOR PLAN GENERAL NOTES FLOOR PLAN GI001 GI002 AD101 GC101 A101 THE GENERAL CONTRACTOR WILL PROVIDE BARRICADES, TEMPORARY LIGHTS, TEMPORARY TELEPHONE SERVICE, AND CLEAN-UP SERVICE TO THE WORK AREA. THE GENERAL CONTRACTOR WILL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE PRIOR TO PROCEEDING WITH THE WORK. THE GENERAL CONTRACTOR WILL COORDINATE WORK ACCORDINGLY WITH ALL SUBCONTRACTORS AND THE OWNER. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE AND THOROUGH CLEAN-UP AT THE END OF THE JOB, AND FOR DAILY REMOVAL OF CONSTRUCTION DEBRIS AND CLEAN-UP. THE GENERAL CONTRACTOR WILL PERFORM MINOR SPACKLING AND REPAIRS TO EXISTING WALLS THROUGHOUT THE WORK AREA, AS IS REQUIRED IN PREPARATION FOR NEW FINISHES. IT WILL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY AND EXECUTE ALL WORK IN ACCORDANCE WITH THE MASSACHUSETTS BUILDING CODE, 8TH EDITION, WITH ALL OF ITS REFERENCED PUBLICATIONS AND ALL OTHER APPLICABLE STATE, FEDERAL, AND LOCAL CODES AND REGULATIONS. IT WILL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO SEE THAT ALL WORK PERFORMED IS IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION'S LIFE SAFETY CODE ( NFPA 101, 2012 ED.). THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS APPLICABLE TO THE SCOPE OF WORK, AS REQUIRED BY THE OWNER, AND AS REQUIRED FOR REGULATORY COMPLIANCE. THE GENERAL CONTRACTOR WILL PROVIDE THE OWNER WITH INSURANCE CERTIFICATES FOR THE REQUIRED INSURANCES PRIOR TO STARTING THE WORK. THE GENERAL CONTRACTOR WILL FILE FOR AND SECURE ALL APPROVALS, PERMITS, AND CERTIFICATES OF COMPLIANCE AS REQUIRED. THE GENERAL CONTRACTOR SHALL FULLY COMPLY WITH THE OWNER'S "INTERIM LIFE SAFETY POLICY" DURING THE ENTIRE CONSTRUCTION PERIOD. CONSTRUCTION CLASSIFICATION OCCUPANCY CLASSIFICATION APPLICABLE CODES & STANDARDS BUILDING CODES AND STANDARDS 1. MASSACHUSETTS STATE BUILDING CODE (780 CMR), 8TH EDITION 2. MASSACHUSETTS ELECTRIC CODE 2014 3. NFPA 101 LIFE SAFETY CODE (2015 EDITION) 4. MASSACHUSETTS ARCHITECTURAL ACCESS BOARD REGULATORS (521 CMR) 5. MASSACHUSETTS STATE PLUMBING CODE (248 CMR) ALTERNATES A2 - ASSEMBLY TYPE 2B INTERIOR ELEVATIONSA201 DETAILSA501 DOOR & WINDOW SCHEDULESA601 ROOM FINISH SCHEDULEAF101 ELECTRICAL PLANE101 REFLECTED CEILING PLANA102 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR ALL WORK THAT IS SHOWN ON THE CONTRACT DRAWINGS THAT IS NOT SPECIFICALLY IDENTIFIED TO BE THAT OF A SUB-CONTRACTOR, INCLUDING ALL WORK THAT IS DESCRIBED BY THE CONTRACT DOCUMENTS THAT IS NOT IDENTIFIED AS BEING ANY SPECIFIC CONTRACTOR'S RESPONSIBILITY. THE SCOPES OF WORK OF THE INDIVIDUAL FIELD SUB-CONTRACTORS ARE IDENTIFIED IN THEIR RESPECTIVE SPECIFICATION SECTIONS. A: A/C WINDOW UNIT TO BE REMOVED; REBUILD WINDOW SASH B: NEW FURNITURE AND FINISHES TO MATCH IN CONFERENCE/ DINING ROOM C C: (NOT USED) D: REMOVE 1 2X2 LIGHT ABOVE SALAD BAR, INSTALL PENDANT LIGHTS E: PAINT 2X2 CEILING TILES & GRID IN ACT SOFFIT (HORIZONTAL AND VERTICAL SURFACES) ALONG NORTH WALL OF SERVING LINE F: REPLACE ALL 2X2 LIGHTS IN ROOM #G-234 G: NEW GLASS DOORS & MANTLE FOR FIREPLACE H: REPLACE ALL WOOD GRAIN LAMINATE ON STAINLESS STEEL EQUIPMENT IN SERVING LINE AREA WITH L1 I: NEW TRIM FOR FIREPLACE J: ELECTRIC INSERT FOR FIREPLACE TITLE SHEET GI001 BW SEAL: MARK DATE ISSUE -01/21/2016 USE GROUP CLASSIFICATION / OCCUPANCY LOAD PROJECT NO: PROJECT ARCHITECT: PROJECT MANAGER: DRAWN BY: DATE: COPYRIGHT: 15-053 REK REK 01/08/2016 SHEET TITLE: CONSULTANT: 64 GOTHIC STREET, SUITE 1 NORTHAMPTON, MA 01060 T 413.585.1512 F 413.586.7945 www.haiarchitecture.com H AI Architecture, Inc. Cafeteria Cooley Dickinson Hospital 30 Locust Street Northampton, MA 01061 Renovation to: PROJECT: A B B R E V I A T I O N S Z O N I N G A N A L Y S I S ZONING DISTRICT: HOSPITAL (SEE INTERNATIONAL BUILDING CODE TABLE 1004.1.1 & CHAPTER 300 "USE AND OCCUPANCY") (EXISTING MIXED USE CONTAINS I2-HOSPITAL AND B-BUSINESS) PRINCIPAL USE: NOT APPLICABLEZONING RESTRICTIONS RELATIVE TO USE: NOT APPLICABLE PARKING REQUIREMENTS: NOT APPLICABLE ADDITIONAL REQUIREMENTS: NOT APPLICABLE G R A P H I C S Y M B O L S INTERIOR ELEVATION DESIGNATION DETAIL IDENTIFICATION ELEVATION LETTER SECTION DESIGNATION ON SHEET WHERE SECTION IS TAKEN; SHEET NUMBER WHERE DRAWN SECTION DESIGNATION ROOM AND NAME NUMBER ON SHEET WHERE DETAIL IS TAKEN; SHEET NUMBER WHERE DRAWN ON SHEET WHERE SECTION IS TAKEN; SHEET NUMBER WHERE DRAWN DETAIL DESIGNATION DOOR NUMBER KEY NOTE WALL TYPE HEIGHT MARK DETAIL DESIGNATION ON SHEET WHERE DETAIL IS TAKEN; SHEET NUMBER WHERE DRAWN DETAIL DESIGNATION SECTION DESIGNATION FIXTURE HEIGHTS 15"-48"MIN. MAX.17"-25"36" MAX.TO SPOUT OUTLET27" MIN.KNEE CLEARANCE48"MAX48"MAX.Per NFPA 72 the strobe shall be no less than 80" and no greater than 96" AFF. When clg heights don't allow for a min. height of 80", strobes shall be mounted within 6" of clg 17" MIN.34" MAX.TO RIMINSULATE ALL PLUMBING W/ TRUEBRO LAVATORY GUARD OR EQUAL FINISH FLOOR 15"-48"MIN MAX48"48" LINE FINISH FLOOR LINE 13-1/2" MIN. FINISH FLOOR LINE The highest operable part of telephone, including dial, handset and coin deposit slots shall be within the reach ranges specified in ABA Section 30815"MINAccessible storage spaces shall be within at least one of the reach ranges specified in ABA Sections 308 29"MIN.27"MIN.40" MAX. TO BTMEDGE OF REFLECTINGSURFACEMount on side wall closest to water closet, can not be mounted behind opposite bars Grab bars shall be between 1-1/4" and LQ™DQGORFDWHGD"FOU from wall HIGHEST OPERABLE PART 15" - 42" DEPENDENTON FORWARD OR SIDE REACH36"x48" CLR. FLR. SPACE FIRE HORN AND LIGHT FIRE EXTINGUISHER CABINET PUBLIC TELEPHONE (ELEVATION) 30"x48" CLR. FLOOR SPACE FOR FORWARD APPROACH PUBLIC TELEPHONE (PLAN) CLOTHES HOOK/ROD DUPLEX RECEPTACLE 30"x48" CLR. FLOOR SPACE LAVATORY (ELEV.)LAVATORY FORWARD APPROACH (PLAN) MIRROR DRINKING FOUNTAIN (PARALLEL APPROACH) FREE STANDING OR BUILT-IN UNITS DRINKING FOUNTAIN (FORWARD APPROACH) WALL & POST MOUNTED CANTILEVERED UNITS ACCESSIBLE DRINKING FOUNTAIN (ELEV.) TOILET PAPER DISPENSER/HOLDER TOILET CLOSEST SIDE WALL GRAB BARS (ELEV.) TOILET REAR WALL GRAB BARS (ELEV.) TOILET (SIDE ELEV.) Flush controls for water closets shall be on the open side of water closet. Operable parts shall be placed w/in one of the reach ranges specified in ABA section 308 TOILET (FRONT ELEV.) URINAL (ELEV.) URINAL (PLAN) MIN. SHOWER CONFIGURATION PLAN SOAP DISPENSER SANITARY NAPKIN - TAMPON DISPENSER PAPER TOWEL DISPENSER20"MAX2'-0"MAX.80"-96" AFFFIRE ALARM PULL STATION42"-48"OPTIONAL POST OR BASE 4'-0"MAX.8" MIN.30"x48" CLR. FLOOR SPACE 30"x48" CLR. FLOOR SPACE6" MAX. TOE CLEARANCE 6" MAX. TOE CLEARANCE 15" - 42" DEPENDENTON FORWARD OR SIDE REACH15" - 42" DEPENDENTON FORWARD OR SIDE REACHNOTE: CONTROLS OF OPERATING MECHANISMS MUST BE PLACED WITHIN AT LEAST ONE OF THE REACH RANGES SPECIFIED IN UFAS SECTION 4.2.5 & 4.2.6 HIGHEST OPERABLE PART FOR FORWARDOR SIDE REACHFOR FORWARDAPPROACHFOR FORWARDAPPROACHSEE PLAN FORUNOBSTRUCTEDSIDE ORFORWARD REACHSIDE WALL 17" MAX.TO RIM44" TYP.FLUSH CONTROLSW/IN REACH RANGEABA SECTION 3089" MIN.TOECLEARANCE17"MIN.5" MAX. 5" MAX. SPOUT LOCATION SPOUT LOCATION 15" MIN. 15" MIN.9" MIN.TOE CLEARANCE8" MIN. KNEE CLEARANCE CLEARANCE AT TOILET (PLAN) 60" MIN.56"MIN.MIRROR 18" 30"x48" CLR. FLOOR SPACE 56"x60" MIN. CLR. FLOOR SPACE -REQUIRED CLEAR FLOOR SPACES, CLEARANCE AT FIXTURES AND TURNING SPACES SHALL BE PERMITTED TO OVERLAP. -DOOR SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE. 1 A101 A B C D 2 A102 1 A101 CONFERENCE ROOM 1005 201 2 CEILING HEIGHT EL. = 100'-0" 36 A101 EXIT REQUIREMENTS: OCCUPANCY LOAD: 3,370 SF @ 15 SF / OCCUPANT = 224 OCCUPANTS (SEE INTERNATIONAL BUILDING CODE TABLE 1004.1.1) MINIMUM EGRESS WIDTH CALCULATIONS (DOORS, RAMPS & CORRIDORS): MINIMUM EGRESS WIDTH CALCULATIONS (STAIRS): NOT APPLICABLE (SEE INTERNATIONAL BUILDING CODE 1009.1, NOT LESS THAN 44") REQUIREMENTS FOR NUMBER OF WATER CLOSETS & LAVATORIES (USE GROUP A2): 2 EXITS REQUIRED; 2 EXITS PROVIDED (SEE INTERNATIONAL BUILDING CODE TABLE 1021.1) DOORS: 44" MIN. REQUIRED, 60" PROVIDED AT STAIR AND CORRIDOR HORIZONTAL EGRESS (SEE INTERNATIONAL BUILDING CODE 1005.1) NOT APPLICABLE; NO CHANGE OF USE C O D E A N A L Y S I S RAMPS: NOT APPLICABLE (SEE INTERNATIONAL BUILDING CODE 1010.5) CORRIDORS: 44" MIN. REQUIRED, 57" PROVIDED (SEE INTERNATIONAL BUILDING CODE 1018.2)33"-36"MIN. MAX.7"-9" MIN. MAX.15"-48"MIN. MAX.12" MAX.42" MIN. 12" MIN.33"-36"MIN. MAX.17"-19"MIN. MAX.36" MIN. 24" MIN. OPENSIDE 54" MIN. TRANSFER SIDE1'-6"33"-36"MIN. MAX.39"-41" MIN. MAX. EYE/FACE WASH (SIDE ELEV.)27" MIN.KNEE CLEARANCE36" MAX.SPRAY HEADCLEARANCE48" MAX. HEIGHTFOR FORWARD REACH30"x48" CLR. FLOOR SPACE EYE/FACE WASH (PLAN) 18" PAPER TOWEL DISPENSER AND WASTE RECEPTACLE4'-0"MAX.HIGHEST OPERABLEPARTFOLD DOWN SEAT AS REQUIRED AIR CONDITIONING INSULATION INTERIOR LAMINATE JOIST JOINT LAVATORY JANITOR INSIDE DIAMETER JST. JT. LAM. LAV. JAN. I.D. INSUL. INT. W W.C. WD. WATER CLOSET WITH WOOD FACE OF FINISH ELECTRIC WATER COOLER FACE OF MASONRY FACE OF STUD FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FIRE HOSE CABINET FINISH FLOOR GYPSUM WALL BOARD HANDICAPPED GENERAL GAUGE GALVANIZED GRADE GENERAL CONTRACTOR GLASS GLAZE HEIGHT HOLLOW METAL HOT WATER HEATER HEATING, VENTILATING AND EXHAUST EXISTING EXPANSION EXTERIOR EAST EXPANSION JOINT ELEVATION ELECTRICAL ELEVATOR EQUAL EQUIPMENT EMERGENCY ROOM DRINKING FOUNTAIN DIAMETER DIMENSION DOWN DOOR DETAIL DRAWINGS CERAMIC TILE FACE OF FOUNDATION WALL F.D. HGT. H.M. H.W.H. HVAC H.C. GA. GEN. GALV. G.C. GL. GRD. G.W.B. GLZ. F.F. F.O.M. F.O.S. FDN. F.E. F.E.C. F.H.C. FIN. FLR. F.O.F. E.J. E.W.C. EX. EXP. EXT. EXH. EL. ELEC. ELEV. EQ. EQUIP. E.R. DIM. DN DR. DTL. DWGS. E DIA. C.T. D.F. SUSPEND(ED) STRUCTURALSTRUCT. SUSP. T.O.W. UR. V.B. V.I.F. VERT. V.C.T. VEST. U.N.O. U.O.D. U.H. T.O.S. T.SLB. THK. TLT. TYP. T.O.F. T.O. TEL. SYS. TOP OF WALL ELEVATION UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE TOP OF STEEL ELEVATION URINAL VERIFY IN FIELD VINYL BASE VESTIBULE VERTICAL TOP OF SLAB UNDERSIDE OF DECK UNIT HEATER TOP OF FOUNDATION THICK TYPICAL TOILET TOP OF TELEPHONE TEMPERED SYSTEM STOR. STL. S.S. SPEC. SIM. SECT. REQ'D R.O. RM. RGH. R.D. REFR. REF. REINF. SPECIFICATIONS STAINLESS STEEL STORAGE STEEL SECTION SIMILAR REQUIRED ROUGH OPENING ROOM ROUGH REFRIGERATOR REINFORCE ROOF DRAIN REFERENCE CLEAR (DIMENSION) CABINET CONTROL JOINT CONCRETE CONSTRUCTION CONTINUOUS CLOSET CENTER CEILING CONCRETE MASONRY UNIT COLUMN COMPACTED (COMPOSITION) CONTRACTOR COL. CONC. CONST. CONT. COMP. CONTR. CLR. CTR. CLG. CMU CL. C.J. CAB. PLYWD. PTN. PT. PTD. PVC PLAM. PLAS. PBD. P.L. N.T.S. OPP. OPG. O.F.C.I. O.C. N.D. NEC. N.I.C. N NAT. PARTITION POLYVINYL CHLORIDE PLYWOOD PAINTED PAINT PARTICLE BOARD PROPERTY LINE PLASTIC LAMINATE PLASTER NOT TO SCALE OPPOSITE ON CENTER OWNER FINISHED, OPENING NECESSARY NATURAL NOT IN CONTRACT NAPKIN DISPENSER NORTH M.E.P. MISC. MULL. M.O. MIN MTL. MFR. MAS. MAX. MECH. PLUMBING MANUFACTURER MISCELLANEOUS MASONRY OPENING MINERAL CORE MULLION METAL MECHANICAL MASONRY MAXIMUM EXTERIOR INSULATION & E.I.F.S. FINISH SYSTEM FIELD VERIFYF.V. MTD.MOUNTED CONTRACTOR INSTALLED O.F.O.I.OWNER FINISHED, OWNER INSTALLED SF SQUARE FOOT STD.STANDARD MECHANICAL, ELECTRICAL, INSULATED HOLLOW METALI.H.M. S SOUTH INSULATED STEELI.S. TI TEMPERED INSULATED KICKPLATE (HEIGHT")K(12) 1/4 W.G.1/4" WIRE GLASS 1/4 T.1/4" TEMPERED GLASS CORNER GUARDC.G. EXISTING TO REMAINE.T.R. S.M.SURFACE MOUNTED ANCHOR BOLT ACOUSTICAL AIR CONDITIONER ADJACENT ABOVE FINISH FLOOR ALTERNATE ALUMINUM ANCHOR ANODIZED ARCHITECT B.L. BD. BLDG. BLK. BLKG. B.O. A.B. ACOUST. A.C. ADJ. A.F.F. ALT. ALUM. ANCH. ANOD. ARCH. BTM. BRG. BRK. BUILDING LINE BOARD BUILDING BLOCK BLOCKING BOTTOM OF BOTTOM BEARING BRICK WEST S.C.W.SOLID CORE WOOD MIN.MINIMUM T.O. T. T.I. U.C.REFR.UNDER COUNTER REFRIGERATOR W/ WITHOUTW/O WITHINW/IN INFORMATION SHEET GI002 BW SEAL: MARK DATE ISSUE -01/21/2016 USE GROUP CLASSIFICATION / OCCUPANCY LOAD PROJECT NO: PROJECT ARCHITECT: PROJECT MANAGER: DRAWN BY: DATE: COPYRIGHT: 15-053 REK REK 01/08/2016 SHEET TITLE: CONSULTANT: 64 GOTHIC STREET, SUITE 1 NORTHAMPTON, MA 01060 T 413.585.1512 F 413.586.7945 www.haiarchitecture.com H AI Architecture, Inc. Cafeteria Cooley Dickinson Hospital 30 Locust Street Northampton, MA 01061 Renovation to: PROJECT: