Loading...
15-053_CDH_Cafeteria_PERMITCAFETERIANORTHAMPTON, MASSACHUSETTS 0106130 LOCUST STREETCOOLEY DICKINSON HOSPITALRenovation to:INDEX TO DRAWINGSTITLE SHEETINFORMATION SHEETDEMOLITION PLANEXISTING CONDITIONS OVERVIEW FLOOR PLANGENERAL NOTESFLOOR PLANGI001GI002AD101GC101A101THE GENERAL CONTRACTOR WILL PROVIDE BARRICADES, TEMPORARY LIGHTS, TEMPORARY TELEPHONE SERVICE, AND CLEAN-UP SERVICE TO THE WORK AREA.THE GENERAL CONTRACTOR WILL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE PRIOR TO PROCEEDING WITH THE WORK. THE GENERAL CONTRACTOR WILL COORDINATE WORK ACCORDINGLYWITH ALL SUBCONTRACTORS AND THE OWNER.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE AND THOROUGH CLEAN-UP AT THE END OF THE JOB, AND FOR DAILY REMOVAL OF CONSTRUCTION DEBRIS AND CLEAN-UP.THE GENERAL CONTRACTOR WILL PERFORM MINOR SPACKLING AND REPAIRS TO EXISTING WALLS THROUGHOUT THE WORK AREA, AS IS REQUIRED IN PREPARATION FOR NEW FINISHES.IT WILL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY AND EXECUTE ALL WORK IN ACCORDANCE WITH THE MASSACHUSETTS BUILDING CODE, 8TH EDITION, WITH ALL OF ITS REFERENCEDPUBLICATIONS AND ALL OTHER APPLICABLE STATE, FEDERAL, AND LOCAL CODES AND REGULATIONS.IT WILL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO SEE THAT ALL WORK PERFORMED IS IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION'S LIFE SAFETY CODE ( NFPA 101, 2012 ED.).THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS APPLICABLE TO THE SCOPE OF WORK, AS REQUIRED BY THEOWNER, AND AS REQUIRED FOR REGULATORY COMPLIANCE.THE GENERAL CONTRACTOR WILL PROVIDE THE OWNER WITH INSURANCE CERTIFICATES FOR THE REQUIRED INSURANCES PRIOR TO STARTING THE WORK.THE GENERAL CONTRACTOR WILL FILE FOR AND SECURE ALL APPROVALS, PERMITS, AND CERTIFICATES OF COMPLIANCE AS REQUIRED.THE GENERAL CONTRACTOR SHALL FULLY COMPLY WITH THE OWNER'S "INTERIM LIFE SAFETY POLICY" DURING THE ENTIRE CONSTRUCTION PERIOD.CONSTRUCTION CLASSIFICATIONOCCUPANCY CLASSIFICATION APPLICABLE CODES & STANDARDSBUILDING CODES AND STANDARDS 1. MASSACHUSETTS STATE BUILDING CODE (780 CMR), 8THEDITION2. MASSACHUSETTS ELECTRIC CODE 20143. NFPA 101 LIFE SAFETY CODE (2015 EDITION)4. MASSACHUSETTS ARCHITECTURAL ACCESS BOARDREGULATORS (521 CMR)5. MASSACHUSETTS STATE PLUMBING CODE (248 CMR)ALTERNATESB - BUSINESSTYPE 2BINTERIOR ELEVATIONSA201DETAILSA501DOOR & WINDOW SCHEDULESA601ROOM FINISH SCHEDULEAF101ELECTRICAL PLANE101REFLECTED CEILING PLANA1021.2.3.4.5.6.7.8.9.10.11.THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR ALL WORK THAT IS SHOWN ON THE CONTRACT DRAWINGS THAT IS NOT SPECIFICALLY IDENTIFIED TO BE THAT OF A SUB-CONTRACTOR, INCLUDING ALLWORK THAT IS DESCRIBED BY THE CONTRACT DOCUMENTS THAT IS NOT IDENTIFIED AS BEING ANY SPECIFIC CONTRACTOR'S RESPONSIBILITY. THE SCOPES OF WORK OF THE INDIVIDUAL FIELDSUB-CONTRACTORS ARE IDENTIFIED IN THEIR RESPECTIVE SPECIFICATION SECTIONS.A: A/C WINDOW UNIT TO BE REMOVED; REBUILD WINDOW SASHB: NEW FURNITURE AND FINISHES TO MATCH IN CONFERENCE/ DINING ROOM CC: (NOT USED)D: REMOVE 1 2X2 LIGHT ABOVE SALAD BAR, INSTALL PENDANT LIGHTSE: PAINT 2X2 CEILING TILES & GRID IN ACT SOFFIT (HORIZONTAL AND VERTICAL SURFACES) ALONGNORTH WALL OF SERVING LINEF: REPLACE ALL 2X2 LIGHTS IN ROOM #G-234G: NEW GLASS DOORS & MANTLE FOR FIREPLACEH: REPLACE ALL WOOD GRAIN LAMINATE ON STAINLESS STEEL EQUIPMENT IN SERVING LINE AREA WITHL1I: NEW TRIM FOR FIREPLACEJ: ELECTRIC INSERT FOR FIREPLACETITLE SHEETGI001BWSEAL:MARK DATEISSUE- - -PROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:15-053REKREK01/08/2016SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.CafeteriaCooley Dickinson Hospital30 Locust StreetNorthampton, MA 01061Renovation to:PROJECT: A B B R E V I A T I O N SZ O N I N G A N A L Y S I SZONING DISTRICT:HOSPITAL (SEE INTERNATIONAL BUILDING CODE TABLE 1004.1.1 & CHAPTER 300 "USEAND OCCUPANCY") (EXISTING MIXED USE CONTAINS I2-HOSPITAL AND B-BUSINESS)PRINCIPAL USE:NOT APPLICABLEZONING RESTRICTIONS RELATIVE TO USE:NOT APPLICABLEPARKING REQUIREMENTS:NOT APPLICABLEADDITIONAL REQUIREMENTS:NOT APPLICABLEG R A P H I C S Y M B O L SINTERIOR ELEVATION DESIGNATIONDETAIL IDENTIFICATIONELEVATION LETTERSECTION DESIGNATIONON SHEET WHERE SECTION IS TAKEN; SHEET NUMBER WHERE DRAWNSECTION DESIGNATIONROOM AND NAME NUMBERON SHEET WHERE DETAIL IS TAKEN; SHEET NUMBER WHERE DRAWNON SHEET WHERE SECTION IS TAKEN; SHEET NUMBER WHERE DRAWNDETAIL DESIGNATIONDOOR NUMBERKEY NOTEWALL TYPEHEIGHT MARKDETAIL DESIGNATIONON SHEET WHERE DETAIL IS TAKEN; SHEET NUMBER WHERE DRAWNDETAIL DESIGNATIONSECTION DESIGNATIONFIXTURE HEIGHTS15"-48"MIN. MAX.17"-25"36" MAX.TO SPOUT OUTLET27" MIN.KNEE CLEARANCE48"MAX48"MAX.Per NFPA 72 the strobe shall be no lessthan 80" and no greater than 96" AFF.When clg heights don't allow for a min.height of 80", strobes shall be mountedwithin 6" of clg17"MIN.34" MAX.TO RIMINSULATE ALL PLUMBINGW/ TRUEBRO LAVATORY GUARDOR EQUALFINISH FLOOR15"-48"MIN MAX48"48"LINEFINISH FLOORLINE13-1/2"MIN.FINISH FLOORLINEThe highest operable part of telephone,including dial, handset and coin deposit slotsshall be within the reach ranges specified inABA Section 30815"MINAccessible storage spaces shall be withinat least one of the reach ranges specifiedin ABA Sections 30829"MIN.27"MIN.40" MAX. TO BTMEDGE OF REFLECTINGSURFACEMount on side wall closest towater closet, can not bemounted behind opposite barsGrab bars shall be between 1-1/4" and1-1/2" in Ø and located a ? 1-1/2" clr.from wallHIGHESTOPERABLEPART15" - 42" DEPENDENTON FORWARD OR SIDE REACH36"x48"CLR. FLR.SPACEFIRE HORN AND LIGHTFIRE EXTINGUISHERCABINETPUBLIC TELEPHONE (ELEVATION)30"x48" CLR. FLOOR SPACEFOR FORWARD APPROACHPUBLIC TELEPHONE(PLAN)CLOTHES HOOK/RODDUPLEX RECEPTACLE30"x48" CLR. FLOORSPACELAVATORY (ELEV.) LAVATORY FORWARDAPPROACH (PLAN)MIRRORDRINKING FOUNTAIN(PARALLEL APPROACH)FREE STANDING ORBUILT-IN UNITSDRINKING FOUNTAIN(FORWARD APPROACH)WALL & POST MOUNTEDCANTILEVERED UNITSACCESSIBLEDRINKING FOUNTAIN(ELEV.)TOILET PAPERDISPENSER/HOLDERTOILET CLOSEST SIDE WALLGRAB BARS (ELEV.)TOILET REAR WALL GRABBARS (ELEV.)TOILET(SIDE ELEV.)Flush controls for water closets shallbe on the open side of water closet.Operable parts shall be placed w/inone of the reach ranges specified inABA section 308TOILET (FRONTELEV.)URINAL(ELEV.)URINAL(PLAN)MIN. SHOWERCONFIGURATION PLANSOAP DISPENSER SANITARY NAPKIN - TAMPONDISPENSERPAPER TOWELDISPENSER20"MAX2'-0"MAX.80"-96" AFFFIRE ALARMPULL STATION42"-48"OPTIONAL POSTOR BASE4'-0"MAX.8"MIN.30"x48" CLR.FLOOR SPACE30"x48" CLR.FLOOR SPACE6" MAX.TOE CLEARANCE6" MAX.TOECLEARANCE15" - 42" DEPENDENTON FORWARD OR SIDE REACH15" - 42" DEPENDENTON FORWARD OR SIDE REACHNOTE: CONTROLS OF OPERATING MECHANISMS MUST BE PLACED WITHIN AT LEAST ONE OF THE REACHRANGES SPECIFIED IN UFAS SECTION 4.2.5 & 4.2.6HIGHESTOPERABLEPARTFOR FORWARDOR SIDE REACHFOR FORWARDAPPROACHFOR FORWARDAPPROACHSEEPLANFORUNOBSTRUCTEDSIDE ORFORWARD REACHSIDE WALL17" MAX.TO RIM44" TYP.FLUSH CONTROLSW/IN REACH RANGEABA SECTION 3089" MIN.TOECLEARANCE17"MIN.5"MAX.5"MAX.SPOUTLOCATIONSPOUTLOCATION15"MIN.15"MIN.9" MIN.TOE CLEARANCE8" MIN.KNEE CLEARANCECLEARANCE ATTOILET (PLAN)60"MIN.56"MIN.MIRROR18"30"x48" CLR.FLOOR SPACE56"x60" MIN. CLR.FLOOR SPACE-REQUIRED CLEAR FLOOR SPACES, CLEARANCE AT FIXTURES AND TURNING SPACESSHALL BE PERMITTED TO OVERLAP.-DOOR SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIREDFOR ANY FIXTURE. DOORS SHALL BE PERMITTED TO SWING INTO THE REQUIREDTURNING SPACE.1A101ABCD2A1021A101CONFERENCEROOM10052012CEILING HEIGHTEL. = 100'-0"36A101EXIT REQUIREMENTS:OCCUPANCY LOAD:3,370 SF @ 100 SF / OCCUPANT = 34 OCCUPANTS (SEE INTERNATIONAL BUILDING CODE TABLE 1004.1.1)MINIMUM EGRESS WIDTH CALCULATIONS (DOORS, RAMPS & CORRIDORS):MINIMUM EGRESS WIDTH CALCULATIONS (STAIRS):NOT APPLICABLE (SEE INTERNATIONAL BUILDING CODE 1009.1, NOT LESS THAN 44")REQUIREMENTS FOR NUMBER OF WATER CLOSETS & LAVATORIES (USE GROUP XX):2 EXITS REQUIRED; 2 EXITS PROVIDED (SEE INTERNATIONAL BUILDING CODE TABLE 1021.1)DOORS: 36" MIN. REQUIRED, 36" PROVIDED (SEE INTERNATIONAL BUILDING CODE 1005.1)NOT APPLICABLE; NO CHANGE OF USEC O D E A N A L Y S I SRAMPS: NOT APPLICABLE (SEE INTERNATIONAL BUILDING CODE 1010.5)CORRIDORS: 36" MIN. REQUIRED, 57" PROVIDED (SEE INTERNATIONAL BUILDING CODE 1018.2)33"-36"MIN. MAX.7"-9"MIN. MAX.15"-48"MIN. MAX.12"MAX.42"MIN.12"MIN.33"-36"MIN. MAX.17"-19"MIN. MAX.36"MIN.24"MIN.OPENSIDE54"MIN.TRANSFERSIDE1'-6"33"-36"MIN. MAX.39"-41"MIN. MAX.EYE/FACE WASH(SIDE ELEV.)27" MIN.KNEE CLEARANCE36" MAX.SPRAY HEADCLEARANCE48" MAX. HEIGHTFOR FORWARD REACH30"x48" CLR.FLOOR SPACEEYE/FACE WASH(PLAN)18"PAPER TOWEL DISPENSERAND WASTE RECEPTACLE4'-0"MAX.HIGHEST OPERABLEPARTFOLD DOWN SEATAS REQUIREDAIR CONDITIONINGINSULATIONINTERIORLAMINATEJOISTJOINTLAVATORYJANITORINSIDE DIAMETERJST.JT.LAM.LAV.JAN.I.D.INSUL.INT.WW.C.WD.WATER CLOSETWITHWOODFACE OF FINISHELECTRIC WATER COOLERFACE OF MASONRYFACE OF STUDFLOOR DRAINFOUNDATIONFIRE EXTINGUISHERFIRE EXTINGUISHER CABINETFIRE HOSE CABINETFINISHFLOORGYPSUM WALL BOARDHANDICAPPEDGENERALGAUGEGALVANIZEDGRADEGENERAL CONTRACTORGLASSGLAZEHEIGHTHOLLOW METALHOT WATER HEATER HEATING, VENTILATING ANDEXHAUSTEXISTINGEXPANSIONEXTERIOREASTEXPANSION JOINTELEVATIONELECTRICALELEVATOREQUALEQUIPMENTEMERGENCY ROOMDRINKING FOUNTAINDIAMETERDIMENSIONDOWNDOORDETAILDRAWINGSCERAMIC TILEFACE OF FOUNDATION WALLF.D.HGT.H.M.H.W.H.HVACH.C.GA.GEN.GALV.G.C.GL.GRD.G.W.B.GLZ.F.F.F.O.M.F.O.S.FDN.F.E.F.E.C.F.H.C.FIN.FLR.F.O.F.E.J.E.W.C.EX.EXP.EXT.EXH.EL.ELEC.ELEV.EQ.EQUIP.E.R.DIM.DNDR.DTL.DWGS.EDIA.C.T.D.F.SUSPEND(ED)STRUCTURALSTRUCT.SUSP.T.O.W.UR.V.B.V.I.F.VERT.V.C.T.VEST.U.N.O.U.O.D.U.H.T.O.S.T.SLB.THK.TLT.TYP.T.O.F.T.O.TEL.SYS.TOP OF WALL ELEVATIONUNLESS NOTED OTHERWISEVINYL COMPOSITION TILETOP OF STEEL ELEVATIONURINALVERIFY IN FIELDVINYL BASEVESTIBULEVERTICALTOP OF SLABUNDERSIDE OF DECKUNIT HEATERTOP OF FOUNDATIONTHICKTYPICALTOILETTOP OFTELEPHONETEMPEREDSYSTEMSTOR.STL.S.S.SPEC.SIM.SECT.REQ'DR.O.RM.RGH.R.D.REFR.REF.REINF.SPECIFICATIONSSTAINLESS STEELSTORAGESTEELSECTIONSIMILARREQUIREDROUGH OPENINGROOMROUGHREFRIGERATORREINFORCEROOF DRAINREFERENCECLEAR (DIMENSION)CABINETCONTROL JOINTCONCRETECONSTRUCTIONCONTINUOUSCLOSET CENTERCEILINGCONCRETE MASONRY UNITCOLUMNCOMPACTED (COMPOSITION)CONTRACTORCOL.CONC.CONST.CONT.COMP.CONTR.CLR.CTR.CLG.CMUCL.C.J.CAB.PLYWD.PTN.PT.PTD.PVCPLAM.PLAS.PBD.P.L.N.T.S.OPP.OPG.O.F.C.I.O.C.N.D.NEC.N.I.C.NNAT.PARTITIONPOLYVINYL CHLORIDEPLYWOODPAINTEDPAINTPARTICLE BOARDPROPERTY LINEPLASTIC LAMINATEPLASTERNOT TO SCALEOPPOSITEON CENTEROWNER FINISHED,OPENINGNECESSARYNATURALNOT IN CONTRACTNAPKIN DISPENSERNORTHM.E.P.MISC.MULL.M.O.MINMTL.MFR.MAS.MAX.MECH.PLUMBINGMANUFACTURERMISCELLANEOUSMASONRY OPENINGMINERAL COREMULLIONMETALMECHANICALMASONRYMAXIMUMEXTERIOR INSULATION & E.I.F.S.FINISH SYSTEMFIELD VERIFYF.V.MTD.MOUNTEDCONTRACTOR INSTALLEDO.F.O.I.OWNER FINISHED,OWNER INSTALLEDSFSQUARE FOOTSTD.STANDARDMECHANICAL, ELECTRICAL, INSULATED HOLLOW METALI.H.M.SSOUTHINSULATED STEELI.S.TITEMPERED INSULATEDKICKPLATE (HEIGHT")K(12)1/4 W.G.1/4" WIRE GLASS1/4 T.1/4" TEMPERED GLASSCORNER GUARDC.G.EXISTING TO REMAINE.T.R.S.M.SURFACE MOUNTEDANCHOR BOLTACOUSTICALAIR CONDITIONERADJACENTABOVE FINISH FLOORALTERNATEALUMINUMANCHORANODIZEDARCHITECTB.L.BD.BLDG.BLK.BLKG.B.O.A.B.ACOUST.A.C.ADJ.A.F.F.ALT.ALUM.ANCH.ANOD.ARCH.BTM.BRG.BRK.BUILDING LINEBOARDBUILDINGBLOCKBLOCKINGBOTTOM OFBOTTOMBEARINGBRICKWESTS.C.W.SOLID CORE WOODMIN.MINIMUMT.O.T.T.I.U.C.REFR.UNDER COUNTER REFRIGERATORW/WITHOUTW/OWITHINW/ININFORMATION SHEETGI002BWSEAL:MARK DATEISSUE- - -PROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:15-053REKREK01/08/2016SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.CafeteriaCooley Dickinson Hospital30 Locust StreetNorthampton, MA 01061Renovation to:PROJECT: G-201AG-2011/2 WALL1/2 WALLG-206AG-214G-206G-194AG-204G-205AG-205G-203G-202AG-202G-122G-190G-189G-191AG-194G-191G-192AG-192G-120G-121G-119G-110G-350G-382G-322G-407ELEV.G-371DNG-419G-417G-383G-111BG-113BG-113CG-112AG-196AG-196G-193G-195G-197G-131AG-115G-115AG-116G-114BG-114AG-108G-109G-114G-112G-112AG-418G-328G-327G-113G-113AG-323G-111AG-110AG-326G-324G-325G-85G-88G-395G-331G-329G-339G-332G-406G-333G-337G-321G-330G-90G-302G-92G-93G-307G-308G-335G-334G-336G-311G-318G-427G-317G-393G-338G-343G-344G-345G-353G-319G-320G-342G-340G-341G-316G-310G-315G-314G-347G-346G-348DNUPG-377G-376G-354G 349G-373G-355G-352G-351G-372G-364G-363G-370G-369G-378G-77G-74G-102G-104G-105G-98G-99G-107G-106G-103G-97G-101G-100G-96G-100AG-94G-291G-69G-290G-420G-72G-305G-58G-289G-282G-285G-283G-277G-275G-276G-22G-09G-05G-04G-01G-07G-95AG-95G-03G-08G-64G-29G-10G-06G-80G-26G-24G-25G-60AG-17G-60G-30G-75G-19G-14G-428G-70G-299G-296G-292G-294G-306G-295G-309G-298G-67G-293G-61G-287G-426G-284G-422G-278G-279G-280G-47G-423G-68G-304G-313G-312G-297G-303G-46G-62G-424G-389G-421G-54G-301G-63G-66G-73G-91G-83G-49G-79G-82G-28G-34G-94G-56G-91G-57G-78G-81G-76G-53G-27G-51G-44G-52G-59G-65G-50G-55G-48G-45G-43SKYLIGHTSKYLIGHTUPGATEDNCHILLERROOM STORAGEUPUPGIFT SHOPG-374FRIG.ATMPHONESTORAGEG-375STAIRG-381STORAGEG-379CORRIDORG-380RESTROOMG-384RESTROOMG-385CARDIO/PULMINARYEXERSISEG-388OFFICEG-386CLOSETG-387PULMINARYFUNCTION ROOMG-396OUTPATIENTPULMINARY CLINICG-397AUTI-COAGULATIONROOMG-398EXAM/STRESSTESTINGG-399HOLTER/EKG/EEGG-400EXAM/MULTI-POURPOSEG-401CONFERENCEG-410ECHO-CARDIOTESTINGG-405CLOSETG-411STRESSTESTG-412LOCKERSSTAFFLOUNGEG-408JAN.G-409STAFFTOILETG-404OFFICEG-394AOFFICEG-394BOFFICEG-402OFFICEG-403RECEPTIONG-391TOILETG-392G-390OFFICEG-361OFFICEG-367OFFICEG-362STORAGEG-358CASHIERG-359JANITORG-360CLOSETG-360ASTORAGEG-357EXAMG-356DNREGISTRATIONG-415BREGISTRATIONG-415CWAITINGG-415RECEPTIONG-414ACORRIDORG-237CONFERENCEROOM DG-236SERVINGLINEG-234KITCHENG-225CAFETERIAG-238F.E.RADIATORRADIATORRADIATORRADIATORRADIATOREXISTINGFIREPLACET.V.TFIRESTAIRSILVERWARE TRAYSSERVINGCOUNTERFRIDGEDISPLAYDISPLAYGRILLMETALCOUNTERHOODMETALCOUNTERPANINIPRESSHOODCLOCKMETALCARTTRUEDISPLAYFRIDGE"DESSERT"(SALAD)FRIDGEMETALTABLETOASTDISP L A Y MENUMETAL TABLETOASTDISPLAYSALADBAR/BUFFETCARTCONVEYORMETALSERVINGCOUNTERCOFFEEDISPENS.COFFEETHERMOSCOFF E E THERMOSCOFFEETHER M O S COFFEETHERMOSCOFF E E THER M O S CREAMCOCA-COLADISPENSERVENDINGMACHINE-BERKSHIRENATURALVENDINGMACHINE-BLUE BUNNYVENDINGMACHINE-ARAMATICVENDINGMACHINE-GREENVENDVENDINGMACHINE-DASANIMETAL CARTMICROMICROICEG-316G-317G-318G-320G-325G-326G-319G-313G-324G-315G-310G-242G-235G-243G-235AG-233G-244G-241G-245G-247G-311G-312G-314G-321G-322G-323G-250G-250AG-254G-257G-331G-256G-329G-328G-327G-261G-262G-263G-264G-265G-260G-266G-258G-255G-253G-259G-252G-251G-219G-218G-217G-217AG-216G-267G-215G-200G-198G-249G-248G-246G-240G-228G-231G-232G-230G-229G-226G-220G-221G-222G-223G-224G-213G-212G-210G-209G-211G-227G-208G-157G-156G-155G-154G-152G-153G-151G-150G-149G-148G-147G-158G-159G-160G-161G-183G-184G-182G-180G-179G-181G-177G-178G-176G-144G-146G-145G-142G-141G-143G-137G-140G-138G-136G-139G-135G-134G-134AG-132AG-132BG-133G-132G-130G-130BG-130AG-131G-207G-185G-186G-187G-188G-126G-127G-125G-127AG-129G-128G-123G-124G-124AG-118G-117BEVERAGE-AIRSANDWICHSTATIONCONVEYOROPENINGROOF OFM.R.I. ROOM(BELOW)CONFERENCE/ DINING CG-249RADIATORRADIATORRADIATORRADIATORRADIATORPROJECT AREAKEY PLANSCALE: NOT TO SCALE20GC101PROJECT AREA1/2 WALL EXISTING CONDITIONSOVERVIEW FLOOR PLANGC101BWSEAL:MARK DATEISSUE- - -PROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:15-053REKREK01/08/2016SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.CafeteriaCooley Dickinson Hospital30 Locust StreetNorthampton, MA 01061Renovation to:PROJECT:PLANNORTHEXISTING CONDITIONS OVERVIEW FLOOR PLANSCALE: 1/16" = 1'-0" REMOVE EXISTING MEDICAL GAS LINES, VALVES, ACCESSORIES, ETC. FROM ALL WALLS ORCEILINGS THAT ARE SCHEDULED TO BE DEMOLISHED. REMOVE THE ASSOCIATED PLUMBINGBACK TO THE NEAREST APPROPRIATE CONCEALED AREA. PROVIDE VALVE AND CAP THELINES. SEE PLUMBING PLANS FOR FURTHER INFORMATION. COORDINATE WORK WITH THEOWNER.REMOVE EXISTING TEL/DATA LINES, RECEPTACLES, AND/OR DEVICES THAT WILL NOT BEREMOVED BY OWNER.REMOVE EXISTING PLUMBING FIXTURES (SINK, WATER CLOSETS, SHOWERS, ETC.) AND ALLACCESSORIES. REMOVE ALL PLUMBING LINES (HOT AND COLD WATER, WASTE AND VENT) TONEAREST CONCEALED AREA (WALL, FLOOR, CEILING OR CHASE). PROVIDE VALVE AND CAPAT APPROPRIATE SOURCE. COORDINATE WITH OWNER'S REPRESENTATIVE FORACCEPTABLE CAP AND VALVE LOCATIONS. PATCH DISTURBED AREAS TO MATCH EXISTINGAND NEW WORK. EXISTING PLUMBING FIXTURES TO BE REMOVED SHALL BE REMOVED TOTHE OWNER'S STORAGE.REMOVE EXISTING LATH AND PLASTER CEILING. PREPARE TOPS OF WALLS AT REMOVEDCEILING FOR SMOOTH TRANSITION TO NEW EXTENSION OF WALLS TO STRUCTURE ABOVE.REMOVE ANY ELECTRICAL DEVICES, (OUTLETS, SWITCHES, LIGHT FIXTURES, CLOCKS, ETC.)WHERE REQUIRED TO ACCOMMODATE NEW CONSTRUCTION. ALSO REMOVE ALL RELATEDWIRING AND CONDUIT, EXCEPT WHERE THE CONDUIT IS SCHEDULED TO REMAIN FOR REUSE.REMOVE THE CONDUIT AND WIRING BACK TO THE NEAREST CONCEALED AREA (WALL,FLOOR, CEILING OR CHASE) AND DISCONNECT THAT CIRCUIT FROM THE BUILDING'S POWERSYSTEM. SEE ELECTRICAL PLANS FOR EXACT LOCATIONS OF ELECTRICAL DEVICES TO BEREMOVED. PATCH AND REPAIR SURFACES AS REQUIRED TO MATCH EXISTING AND NEWWORK. REMAIN EXISTING ELECTRICAL DEVICES AT EXISTING WALLS TO REMAIN (TYPICAL)REMOVE WALL COVERING, WHERE PRESENT, INCLUDING CERAMIC TILE AND/OR SPECIALTYPANELS. CLEAN AND PREPARE EXISTING SUBSTRATE AND PATCH HOLES AS REQUIRED TOFACILITATE INSTALLATION OF NEW FINISH AS SPECIFIED IN THE FINISH SCHEDULE.REMOVE EXISTING DOORS AND DOOR FRAMES AS SCHEDULED. PATCH AND REPAIR WALLS,FLOORS AND CEILINGS TO MATCH EXISTING AND NEW WORK AS SCHEDULED. RELOCATE ANDREFINISH/RECONDITION DOORS THAT ARE SCHEDULED TO BE RELOCATED IN THE DOORSCHEDULE.REMOVE EXISTING SUSPENDED ACOUSTICAL CEILING SYSTEM TILES. REPAIR AND REFINISHALL TRACKS. PATCH & REPAIR WALLS AS REQUIRED TO MATCH NEW & EXISTING WORK TOREMAIN.REMOVE EXISTING BASE (VINYL, TILE, ETC.). CLEAN AND PREPARE THE EXISTING SUBSTRATEAS REQUIRED TO FACILITATE THE INSTALLATION OF NEW BASE. SEE ROOM FINISH SCHEDULEFOR NEW BASE TYPE.REMOVE EXISTING FLOOR COVERING (VINYL, TILE, ETC.); PATCH AND REPAIR FLOOR ASREQUIRED. CLEAN AND PREPARE THE EXISTING SUBSTRATE AS REQUIRED TO FACILITATETHE INSTALLATION OF NEW FLOOR COVERING. (SEE ROOM FINISH SCHEDULE FOR NEWFLOOR COVERING). NOTE: ALL FLOORS IN ROOMS OR AREAS THAT ARE SCHEDULED TORECEIVE NEW FLOOR COVERING WILL HAVE THE EXISTING FLOOR COVERING REMOVED INTHAT AREA, UNLESS NOTED OTHERWISE. GENERAL CONTRACTOR TO INSURE THAT THEFLOOR IS LEVEL PRIOR TO INSTALLING NEW FLOORING.REMOVE EXISTING CABINET WORK, COUNTERS, SHELVING, EQUIPMENT AND OTHER BUILT - INITEMS AS SHOWN OR OTHERWISE CALLED OUT TO BE REMOVED. PATCH SURFACES ASREQUIRED TO RECEIVE NEW FINISH SURFACES.WHERE EXISTING PARTITIONS, OR PORTIONS OF SAME, ARE REMOVED, TO ACCOMMODATENEW DOORS OR WINDOWS, COUNTERS, OR CABINETS BECAUSE OF DEMOLITION, PATCH ANDREPAIR WALLS, FLOORS, AND CEILINGS TO MATCH EXISTING AND NEW WORK ASSCHEDULED. WHERE EXISTING CMU WALLS ARE REMOVED TO ACCOMMODATE NEW DOORSOR WINDOWS, PROVIDE NEW LINTELS OVER THE OPENING AS REQUIRED. SEE LINTELSCHEDULE. LEAVE JAMBS CLEAN AND SQUARE FOR APPLICATION OF NEW DOOR OR WINDOWFRAME.PROVIDE TEMPORARY DUSTPROOFING PARTITIONS AT ALL EXISTING AREAS THAT ABUT THEWORK AREA AND WHERE INDICATED ON THE DRAWINGS. TEMPORARY PARTITIONING SHALLBE LOCKABLE, AND SHALL EXTEND FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE. SEEDRAWINGS FOR LOCATIONS. SEE DETAIL 16/AD101.THE FOLLOWING DEMOLITION NOTES REFER ONLY TO THE GENERAL SCOPE OF DEMOLITION REQUIREDTO COMPLETE THIS PROJECT, AND MAY NOT SPECIFICALLY IDENTIFY EACH AND EVERY COMPONENT OFAN ARCHITECTURAL, MECHANICAL, OR ELECTRICAL SYSTEM OR ASSEMBLY (WHETHER DESIGNATED ONTHE DEMOLITION PLAN (S) OR NOT). THE GENERAL CONTRACTOR AND HIS/HER SUBCONTRACTORS SHALLBE REQUIRED TO REMOVE/DEMOLISH INCIDENTAL ITEMS THAT MAY BE CONSTRUED TO BE RELEVANT TOTHE SCOPE OF DEMOLITION SHOWN ON THE DEMOLITION PLAN(S), OR REQUIRED TO COMPLETE THE NEWWORK. THE GENERAL CONTRACTOR SHALL BE REQUIRED TO DEMOLISH SPECIFIC ITEMS, WHETHER ORNOT THEY ARE SPECIFICALLY INDICATED.THE GENERAL CONTRACTOR SHALL BE REQUIRED TO CUT ALL HOLES IN FLOORS, WALLS, CEILINGS, ETC.AS REQUIRED FOR MECHANICAL OR ELECTRICAL WORK IDENTIFIED IN THE CONTRACT DOCUMENTS(INCLUDING, BUT NOT LIMITED TO DUCTWORK, HYDRONIC PIPING, FIRE SUPPRESSION PIPING, PLUMBINGPIPING, AND/OR ELECTRICAL CONDUIT FOR POWER / DATA / LOW VOLTAGE / SPECIALTY SYSTEMS).GENERALLY, THOSE PENETRATIONS ARE NOT SHOWN ON THE CONTRACT DRAWINGS; HOWEVER, THEGENERAL CONTRACTOR (OR APPROPRIATE SUBCONTRACTOR) SHALL BE RESPONSIBLE FOR CORINGOPERATIONS, AND SLEEVING PENETRATIONS WHERE REQUIRED, WITH A MATERIAL THAT IS SUITED TOTHE TYPE OF PENETRATION AND RATING OF THE ASSEMBLY BEING PENETRATED. THE GENERALCONTRACTOR SHALL BE REQUIRED TO PATCH AND REPAIR ALL DAMAGED SURFACES TO MATCH EXISTINGAND/OR AS REQUIRED BY THE NEW WORK.DEMOLITION NOTES1REMOVE EXISTING INTERIOR WINDOW ASSEMBLIES INCLUDING INTERIOR TRIM ASSCHEDULED. PATCH AND REPAIR WALLS, FLOORS, AND CEILING TO MATCH EXISTING ANDNEW WORK AS SCHEDULED.REMOVE EXISTING STUD PARTITIONS, CMU OR BRICK OR PORTIONS OF SAME (INCLUDINGALL ELECTRICAL DEVICES AND WIRING, PLUMBING FIXTURES AND PIPING AND ANY OTHERITEMS MADE OBSOLETE BY THE REMOVAL OF THE PARTITION), CHASES, DOORS, FRAMESAND MISCELLANEOUS CONSTRUCTION ITEMS. PATCH AND REPAIR WALLS, FLOORS, CEILINGSTO MATCH EXISTING AND NEW WORK AS SCHEDULED.REMOVE PORTION OF EXISTING HANDRAILS/ CHAIR RAILS. MODIFY ENDS TO RETURN TOWALL - MATCH EXISTING.MODIFY EXISTING STAINLESS STEEL COUNTER FOR ADDITION OF NEW SINK.REMOVE EXISTING FIRE PROTECTION PIPING AND HEADS AS REQUIRED TO SUIT NEW WORK.EXTEND AND/OR RECONFIGURE PIPING AS REQUIRED - SEE FIRE PROTECTION DRAWINGSFOR FURTHER INFORMATION. COORDINATE ANY REQUIRED SHUT DOWNS WITH THE OWNER.2345678910111213141516171820REMOVE CEILING ACCESSORIES.19REMOVE EXISTING HVAC DUCTWORK VALVES, CONTROLS, WIRING, THERMOSTATS, DUCTHANGERS, RADIATORS, RADIATOR ENCLOSURE COVERS AND ALL EQUIPMENT ACCESSORIES,ANY MISCELLANEOUS HVAC ACCESSORIES THAT REQUIRE REMOVAL WITH THE DEMOLITIONOF WALLS AND/OR CEILINGS. REMOVE THE DUCTWORK AND PIPING BACK TO THE NEARESTAPPROPRIATE CONCEALED AREA AND CAP THE DUCTS AND LINES IN QUESTION. PATCH ANDREPAIR SURFACES AS REQUIRED TO MATCH EXISTING AND NEW WORK AND MAINTAINREQUIRED FIRE RATINGS. SEE HVAC DRAWINGS FOR FURTHER INFORMATION. COORDINATEWITH OWNER'S REPRESENTATIVE FOR INFECTION CONTROL POLICIES.DEMOLITION KEY NOTESDEMOLITIONEXISTING CONSTRUCTIONLEGENDTEMPORARY DUSTPROOFING PARTITIONS1IF HAZARDOUS MATERIALS ARE ENCOUNTERED DURING DEMOLITION OPERATIONS, IMMEDIATELYNOTIFY OWNER AND COMPLY WITH APPLICABLE REGULATIONS, LAWS, AND ORDINANCESCONCERNING REMOVAL, HANDLING AND PROTECTION AGAINST EXPOSURE OR ENVIRONMENTALPOLLUTION.CEILINGSEE R.C.P."ZIP WALL" EXPANDABLE BRACING SYSTEMFLOOR LINEMETAL STUD TRACK AT ENTIRE PERIMETEROF PLASTICAPPROVED FIRE RATED DUST BARRIERPLASTIC SHEETING - CONTINUOUS. PROVIDECOORDINATING ZIPPER ACCESS PANEL ASREQUIREDEXISTING CEILING TO REMAINLINE OF STRUCTURAL DECK OR SLAB ABOVECOMPRESSIBLE SEAL AT BOTTOM TRACKTEMPORARY PARTITIONSCALE: 1" = 1'-0"16AD101CORRIDORG-237CONFERENCEROOM DG-236SERVINGLINEG-234KITCHENG-225FIRESTAIRCONFERENCE/DINING CG-249G-310G-242G-235G-243G-235AG-233SERVINGCOUNTERMETAL COUNTERPROJECT AREACAFETERIAG-238RELOCATE WET CHEMICAL FIRE SUPPRESSIONSYSTEM FROM DEMO'D MILLWORKDEMOLITION OF CHAIR RAIL BEYOND LINE OF NEW WALLREMOVE EXISTING SECURITY DOMEALTERNATE A: A/C WINDOWUNIT TO BE REMOVED;REBUILD WINDOW SASH841818442420777(ALL WALLPAPER IN ENTIREPROJECT AREA)7777191616RELOCATE EXISTING SECURITY CAMERA;SEE R.C.P.77ALTERNATE D: DEMO 2X2 LIGHT ABOVESALAD BARDEMOLITION OF EXISTING MILLWORK; CASHREGISTER AND PHONE TO BE RELOCATED.PATCH FLOOR WHERE REQUIRED.DEMOLITION OF EXISTING MILLWORK &WALL; PATCH FLOOR WHERE REQUIRED.RELOCATE T.V. AND I.T. EQUIPMENT TO NEWDISPLAY ALCOVE4ALTERNATE F: REMOVE ALL(17) 2X2 LIGHTS IN RM #G-234555666561010DEMOLITION PLANAD101BWSEAL:MARK DATEISSUE- - -PROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:15-053REKREK01/08/2016SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.CafeteriaCooley Dickinson Hospital30 Locust StreetNorthampton, MA 01061Renovation to:PROJECT:PLANNORTHDEMOLITION PLANSCALE: 1/4= 1'-0" KEY PLANSCALE: NOT TO SCALE20A101PROJECT AREA1/2 WALLFURNITURE SHOWN ON DRAWINGS, EXCEPT CASEWORK, IS NOT INCLUDED IN THIS CONTRACTUNLESS NOTED OTHERWISE.10.ALL DOORS AND WALLS NOT LABELED WITH A WALL TYPE OR DOOR NUMBER ARE TO BECONSIDERED EXISTING TO REMAIN.9.GENERAL CONTRACTOR TO PROVIDE BLOCKING AS REQUIRED FOR ALL WALLS, NEW OR EXISTING,THAT ARE TO RECEIVE NEW OR EXISTING CABINETRY, SHELVING, ETC.8.WHERE UTILITY AND MECHANICAL WORK IS REMOVED OR ALTERED, GENERAL CONTRACTOR ISRESPONSIBLE FOR PREPARING AND PATCHING BUILDING STRUCTURE TO MATCH NEW ANDEXISTING WORK AS INDICATED ON DRAWINGS.7.ALL WORK TO BE CONSIDERED AS NEW WORK UNLESS INDICATED AS EXISTING TO REMAIN.6.CONSTRUCT NEW INTERIOR PARTITIONS FROM FLOOR TO THE BOTTOM OF THE STRUCTURE(DECK OR SLAB) ABOVE UNLESS NOTED OTHERWISE VERIFY IN FIELD.5.REPAIR ANY IRREGULARITIES IN SURFACES INCLUDING BUT NOT LIMITED TO AREAS DISTURBEDBY NEW WORK.4.PROVIDE TEMPORARY DUST PROOFING PARTITIONS TO EFFECTIVELY SEAL OFF WORK AREASFROM THE REST OF THE BUILDING. PROVIDE TEMPORARY DOOR IF NECESSARY.3.2.ANY REPAIRS, PATCHING, OR DEMOLITION INDICATED ON DRAWINGS REPRESENT THE GENERALAREA WHERE WORK IS TO BE DONE, BUT DOES NOT NECESSARILY LIMIT THE EXTENT OF WORK.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL SUCH REPAIRS, PATCHING, ETC. WHERETHEY OCCUR IN BUILDING UNDER THIS CONTRACT.1.GENERAL CONTRACTOR MUST VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE ANDREPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH THE WORK.GENERAL CONSTRUCTION NOTESROOM NAME AND ROOM NUMBERDOOR NUMBERNEW WALL CONSTRUCTIONEXISTING CONSTRUCTIONLEGENDWALL TYPEPRIVACY CURTAIN (N.I.C.)NEW HALF WALL CONSTRUCTION (U.N.O.)ROOMNAMEXXXXXX1NEW MILLWORK / CASEWORK WITH PLASTIC LAMINATE COUNTERTOPNEW MILLWORK / CASEWORK WITH SOLID SURFACE COUNTERTOPCORRIDORG-237CONFERENCEROOM DG-236SERVINGLINEG-234KITCHENG-225T.V.FIRESTAIRPPIZZADISPLAYTOASTDISPLAYCOCA- COLA FRIDGE ICE CREAM CONFERENCE/DINING CG-249G-310G-242G-235G-243G-235AG-233SERVINGCOUNTERMETAL COUNTER CONVEYORPROJECT AREAABCD2A201G-234AG-234BC1A201W1NEW 6'-0" DOUBLE DOORTO BE PROPPED OPENDURING BUSINESSHOURSEXISTINGFIRE-PLACEEXISTING CONVEYOROPENINGNEW BUILT-IN DISPLAYSHELVING AGAINST 3"GYPSUM WALL; SEEDETAIL 1/A501ALTERNATE A: A/C WINDOWUNIT TO BE REMOVED;REBUILD WINDOW SASHNEW WALL & WINDOWS;COORDINATE WITHSOFFIT ABOVE.REPLACE F.R.P. PANELS ATCONVEYOR BELTNEW CASHIER MILLWORKWITH RELOCATED CASHREGISTER & WALL PHONESILVERWARE &CONDIMENTSEXISTING PREP SINK TO REMAINNEW HANDWASHING SINK; MODIFYEXISTING STAINLESS STEEL COUNTERDIGITAL MENU (SUSPENDED)RECYCLINGAREARECYCLING SIGNAGE OPTIONSREPLACE "DESSERT"FRIDGE WITH NEWDEDICATEDPRODUCE FRIDGEDISPLAY ALCOVE W/RELOCATED TV & I.T.EQUIPMENT; CONCEAL WIRESIN WALLDISPLAYSALTERNATE B: NEW FURNITUREAND FINISHES TO MATCHAFTER- HOURS TRASHLOCATIONALL NEW DININGTABLES AND CHAIRSNEW FURNITURE & FINISHES TO MATCH1012"2'-10"5'-512" CLEAR10"3'-2"3'-0"3'-212"8'-5"3'-034" ±V.I.F.312"6'-1"V.I.F.16'-312"V.I.F.15'-6"V.I.F.6'-4"CLEAR9'-7"V.I.F.2'-1012" ±V.I.F.1012"3'-9"4'-5"912"912"1012"10'-412" V.I.F.3'-612"V.I.F.EQ.EQ.ACD6A201FIREPLACE:ALTERNATE G: NEW GLASS DOORS & MANTLE;ALTERNATE I: NEW TRIM;ALTERNATE J: ELECTRIC INSERT5"1CAFETERIAG-238CONDIMENTS/SILVERWARE1'-4"1'-11"2'-11"ALTERNATE H: REPLACE ALL WOOD GRAINLAMINATE ON STAINLESS STEEL EQUIPMENT INSERVING LINE AREA WITH L1SILVERWARE512"1"2'-2"1"A12A2012'-8" TRAYSBFLOOR PLANA101BWSEAL:MARK DATEISSUE- - -PROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:15-053REKREK01/08/2016SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.CafeteriaCooley Dickinson Hospital30 Locust StreetNorthampton, MA 01061Renovation to:PROJECT:PLANNORTHFLOOR PLANSCALE: 1/4" = 1'-0" ALL NEW SPRINKLER HEADS TO BE CENTERED IN THE NEW CEILING GRID SYSTEM.(COORDINATE LOCATIONS WITH FIRE PROTECTION PLAN AND ALL OTHER TRADES).REFLECTED CEILING NOTES1.2.COORDINATE NEW CEILING WORK WITH ALL NEW AND EXISTING CEILING ITEMS,ACCESSORIES AND SYSTEMS.3.SEE H.V.A.C. DRAWINGS FOR ALL NEW EXHAUST GRILLES AND DIFFUSERS, COORDINATE ALLNEW DIFFUSERS WITH NEW CEILING GRID LAYOUT, LIGHTS, SPEAKERS, SPRINKLERS, ETC....CENTER ALL NEW ACOUSTICAL CEILING TILES IN BOTH DIMENSIONS IN ALL ROOMSSCHEDULED TO RECEIVED NEW SUSPENDED ACOUSTICAL TILE UNLESS SHOWNDIFFERENTLY ON DRAWINGS.4.5.SEE ELECTRICAL LIGHTING PLAN AND SCHEDULE FOR ALL LIGHTING FIXTURES.6.ALL NEW SMOKE AND HEAT DETECTORS SHALL BE CONNECTED TO THE EXISTING FIREALARM SYSTEM.7.ALL SUSPENDED CEILINGS SHALL BE EQUIPPED WITH RETENTION CLIPS AT NEW TILE (I. E. @ENTRANCE VESTIBULES, LOBBIES, ALL CORRIDORS THAT LEAD DIRECTLY TO THE EXTERIOR,AND THROUGHOUT ALL BEHAVIORAL HEALTH PROJECTS).8USE HARDWARE FRIENDLY OPTIONS AT ALL LIGHT FIXTURES AND OTHER ACCESSORIES.GAPS BETWEEN FIXTURE TRIM AND REVEALS ARE NOT ACCEPTABLE.MEP WORK TO BE DESIGN BUILDEXISTING CEILING TO REMAINREFLECTED CEILING KEYED NOTESEXISTING SOFFIT TO REMAINUSG MARS CLIMA PLUS #86785, 24"x24" TEGULAR TILE, COLOR: WHITE WITH 15/16"TEE GRID SYSTEM, COLOR: WHITECEILING TYPE SCHEDULETYPE 1ATYPE 2AUSG ASTRO CLIMA PLUS #8223, 24"x24" TEGULAR TILE, COLOR: WHITE WITH 15/16"TEE GRID SYSTEM, COLOR: WHITEUSG MARS CLIMA PLUS #88785, 24"x48" TEGULAR TILE, COLOR: WHITE WITH 15/16"TEE GRID SYSTEM, COLOR: WHITETYPE 1BTYPE 2BUSG ASTRO CLIMA PLUS #8243, 24"x48" TEGULAR TILE, COLOR: WHITE WITH 15/16"TEE GRID SYSTEM, COLOR: WHITETYPE 3AUSG RADAR CLIMA PLUS #2220, 24"x24" TEGULAR TILE, COLOR: WHITE WITH 15/16"TEE GRID SYSTEM, COLOR: WHITETYPE 3BUSG RADAR CLIMA PLUS #2420, 24"x48" TEGULAR TILE, COLOR: WHITE WITH 15/16"TEE GRID SYSTEM, COLOR: WHITETYPE 4USG SHEET ROCK CLIMA PLUS #3270, 24"x48" LAY-IN TILE, COLOR: WHITE WITH15/16" TEE GRID SYSTEM, COLOR: WHITETYPE 5 PLASTIC LAMINATE SOFFITS - SEE DETAILSGYPSUM BOARD CEILING AND SOFFITS - SEE DETAILSTYPE 612SUSPENDED ACOUSTICAL CEILING SYSTEMREFLECTED CEILING LEGEND2'x4' LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS2'x2' LIGHT FIXTURE - SEE ELECTRICAL DRAWINGSRECESSED DOWNLIGHT - SEE ELECTRICAL DRAWINGSCEILING MOUNTED EXIT SIGN - SEE ELECTRICAL DRAWINGSWALL MOUNTED EXIT SIGN - SEE ELECTRICAL DRAWINGSCEILING CURTAIN TRACK1'x4' LIGHT FIXTURE - SEE ELECTRICAL DRAWINGSSPRINKLER HEAD - SEE FIRE PROTECTION DRAWINGSSECURITY CAMERA - SEE ELECTRICAL DRAWINGSGYPSUM BOARD CEILING / SOFFITCEILING MOUNTED SUPPLY GRILLE OR DIFFUSER - SEE HVAC DRAWINGSCEILING MOUNTED RETURN OR EXHAUST GRILLE - SEE HVAC DRAWINGSSCEILING MOUNTED SPEAKER - SEE ELECTRICAL DRAWINGS2' UNDERCABINET LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS4' UNDERCABINET LIGHT FIXTURE - SEE ELECTRICAL DRAWINGSBOX SOFFIT ABOVE CABINETRYEXISTING TO REMAINERELOCATED EXISTING DEVICE/FIXTURERLLOCATION OF RELOCATED DEVICE/FIXTURENLPLASTIC LAMINATE CEILING / SOFFITCEILING TYPECEILING HEIGHT ABOVE FINISH FLOORCEILING MOUNTED SMOKE DETECTOR - SEE ELECTRICAL DRAWINGSFSCEILING MOUNTED MOTION DETECTOR - SEE ELECTRICAL DRAWINGSMDHFCEILING MOUNTED HEAT DETECTOR - SEE ELECTRICAL DRAWINGSCORRIDORG-237CONFERENCEROOM DG-236SERVINGLINEG-234KITCHENG-225FIRESTAIRPCONFERENCE/DINING CG-249G-310G-242G-235G-243G-235AG-233PROJECT AREACAFETERIAG-238REPLACE (4) EXISTING 2X4SURFACE-MOUNTED LIGHTSWITH NEW 2X4SURFACE-MOUNTED LEDLIGHTS; SEE SPEC.ALTERNATE D: (3) NEW PENDANT LIGHTSOVER SALAD BAR; SEE SPEC, REMOVAL OF (1)2X2 LIGHTRELOCATED SECURITY CAMERA(DIRECTLY ABOVE CASH REGISTER)REPLACE (5) EXISTING SURFACE-MOUNTED 1X4LIGHTS WITH NEW SURFACE-MOUNTED 1X4 LEDLIGHTS; SEE SPEC.REPLACE 2X2 CEILING TILESAND ADD GRID CAPSALTERNATE E: PAINT (P4) 2X2 CEILINGTILES & GRID WITHIN ACT SOFFIT(HORIZONTAL & VERTICAL SURFACES); SEEFINISH SCHEDULE.1'-1"1'-5"2'-512"7'-10"8'-438" ±3'-034"3'-212"2'-212"3'-1112"EXTEND EXISTING SPRINKLER HEAD ASREQUIRED BY NEW SOFFITALTERNATE F: REPLACE ALL(17) 2X2 LIGHTS IN RM #G-234WITH NEW L.E.D.; SEE SPEC.(TOTAL 16 IF 1 IS REMOVEDFOR ALT. D)CLEAN, REPAIR WHERE POSSIBLE,AND PAINT 1X1 CEILING TILES PERFINISH SCHEDULECLEAN, REPAIR WHERE POSSIBLE,AND PAINT 1X1 CEILING TILES PERFINISH SCHEDULEREPLACE ANY WATER-DAMAGED2X2 CEILING TILESDIGITAL MENU (SUSPENDED)CLEAN, REPAIR WHERE POSSIBLE,AND PAINT 1X1 CEILING TILES PERFINISH SCHEDULECLEAN, REPAIR WHERE POSSIBLE,AND PAINT 1X1 CEILING TILES PERFINISH SCHEDULE(DEMO) (ALT. D-DEMO)2'-0"2'-0"4'-2"3'-2"REFLECTED CEILING PLANA102BWSEAL:MARK DATEISSUE- - -PROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:15-053REKREK01/08/2016SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.CafeteriaCooley Dickinson Hospital30 Locust StreetNorthampton, MA 01061Renovation to:PROJECT:PLANNORTHREFLECTED CEILING PLANSCALE: 1/4" = 1'-0" INTERIOR ELEVATIONSSCALE: 1/4" = 1'-0"6A101DINING ROOMEXISTING TILE BASE TO REMAIN;TERMINATE AT LINE OF NEW WALLBASE PER FINISH SCHEDULE (TYP.)EXISTING TILE BASE TO REMAINEXISTING CHAIR RAIL TO REMAIN;REFINISH; TERMINATE AT LINE OFNEW WALLEXISTING CHAIR RAIL TO REMAIN;STRIP AND REFINISH (P1)EXISTING FIRE DOORS TOREMAIN; REFINISH WITHPAINT P1EXISTING CROWN MOLDING TOREMAIN; STRIP AND REFINISH (P1)EXISTING CROWN MOLDING TOREMAIN; REPAIR AND REFINISH(P1)EXISTING BEAM & CROWN MOLDING TOREMAIN; REPAIR CRACKS & DAMAGE ANDREFINISH (P1.)AWATER/ICEALCOVE TO MATCHTYP. EXISTINGWINDOW DIMENSIONS;PAINT INSIDE P46'-0" DOUBLE DOOR TO BEPROPPED OPEN DURINGBUSINESS HOURSNEW WINDOWS TOSERVING LINE AREAINTERIOR ELEVATIONSSCALE: 1/4" = 1'-0"2A101SERVING LINE (CHECK-OUT AREA)W1SILVERWARE & CONDIMENTSCAM LOCKS AT EACHCABINET DOOR PAIR8A5018A501SERVING LINEINTERIOR ELEVATIONSSCALE: 1/4" = 1'-0" 1A101C1A501CONSTRUCT NEW DISPLAYSHELVES IN PLACE OFEXISTING DOORWAYBASE PER FINISH SCHEDULE9"1'-0"1'-112"V.I.F.C2'-10"CAFETERIA INFORMATIONAL/NUTRITIONAL SIGNAGEDISPLAYSBASE PER FINISH SCHEDULE4"2'-10"2'-10"2A5014"D1012"±4"AB4"2'-10"OPEN5A5017A5014A501STORAGE FOR EXTRACONDIMENTS, SILVERWARE,ETC.2A501STORAGE FOR EXTRA IMPULSE-BUYS FOR DISPLAYS, ETC.BASE PER FINISH SCHEDULESOFFIT- SEE R.C.P.2'-2"2'-6"3'-0"1'-9"2'-4"4"2'-3" ±2'-4"2'-1012" ±V.I.F.3'-9"2" FILLERBASE PER FINISH SCHED.SOFFIT- SEE R.C.P. EXISTING BEAM- SEE R.C.P.SOFFIT- SEE R.C.P.2'-1012" ±V.I.F.6'-1012" ± (V.I.F.)1'-0"1'-0"1'-0"1'-0"P. LAM ON ALL EXPOSEDSURFACESCEXISTING SOFFIT; PAINT P4 PERFINISH SCHEDULEPAINT TRIM P1 PER FINISH SCHEDULEPAINT ALCOVES P4 PER FINISH SCHED.EX. RADIATOREX. RADIATOREX. RADIATOREX. RADIATOREX. RADIATORAREA UNDER CHAIR RAIL PAINTED P1PER FINISH SCHEDULEINTERIOR ELEVATIONSCALE: 1/4" = 1'-0" 11A101DINING ROOMDEX.RADIATR.I.T.BOXEXISTINGFIREPLACEALTERNATE G: NEW GLASS DOORS &MANTLERELOCATEDT.V.BASE PER FINISH SCHEDULE (TYP.)AREA UNDER CHAIR RAIL PAINTED P1PER FINISH SCHEDULEEXISTING CHAIR RAIL TO REMAIN;STRIP AND REFINISH (P1)PAINT ALL TRIM P1 PER FINISHSCHEDULEPAINT SOFFIT P4 PER FINISHSCHEDULEPAINT ALCOVE P4 PER FINISHSCHEDULECOLUMN INSETS- PAINT P4COLUMN INSET TRIM- PAINT P1COLUMN CAP- PAINT P1COLUMN & CAPITAL- PAINT P1COLUMN BASE- PAINT P1G-234B2'-6"4'-6"DISPLAYS/ IMPULSE-BUYS5A5019A5011'-914" ±V.I.F.1'-1"1" COUNTERTOPOVERHANGS (TYP.)1" COUNTERTOPOVERHANGS (TYP.)1" COUNTERTOPOVERHANGS (TYP.)5A5012'-0"1" COUNTERTOPOVERHANGS (TYP.)G-234BMIRROR ORWALL ARTSTRIP & REFINISH EXISTING FRAME(P1)P. LAM L1 (TYP.)P. LAM L2 (APRONACCENTS)INTERIOR ELEVATIONSCALE: 1/4" = 1'-0" 12A101SERVING LINEAALTERNATE I: NEW TRIM FORFIREPLACE11A5012'-2" ±V.I.F.3'-0"BASE PER FINISH SCHEDULE(8) SILVERWARE CUPS- 4"DIAMETER HOLESSTORAGE UNDERNEATH ONREAR (STAFF) SIDEEXISTING STAINLESSSTEEL SERVINGCOUNTER; ALTERNATE H:REPLACE ALL WOODGRAIN LAMINATE WITH L1(TYPICAL ALL EXISTING)TRAYSL2 L22'-10"4"4"4"4"1'-812"1'-812"L2 L2 L2 L2ALTERNATE J: ELECTRIC INSERTFOR FIREPLACEB12A5013'-7"3'-1"BEAM- PAINT P4INTERIOR ELEVATIONSA201BWSEAL:MARK DATEISSUE- - -PROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:15-053REKREK01/08/2016SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.CafeteriaCooley Dickinson Hospital30 Locust StreetNorthampton, MA 01061Renovation to:PROJECT: FINISHED FLOORBASE AS SCHEDULE9"ADJUSTABLE P. LAM. SHELVES 10 1/2"DEEP - SEE ROOM FINISH SCHEDULE.PROVIDE BLOCKING AS REQ'D. P.LAM.ON ALL EXPOSED SURFACES.CEILINGEL. = SEE R.C.P.SHELVES DETAILSCALE: 1" = 1'-0"1A201112"CHECK-OUT LINE CABINETSCALE: 1" = 1'-0"2A2011" TYP.BASE PER SCHEDULE6"4"312"1/2" SOLID SURFACE COUNTER WITH EASEDEDGES - SEE FINISH SCHEDULE FOR TYPE2'-10"BASE PER SCHEDULE3-5/8" METAL STUDS @ 16" O.C.IN-WALL BLOCKING AS REQ'DLINE BORE SYSTEM @ 1-1/4" O.C. BOTHSIDES TO RECEIVE HORIZONTAL SHELFS.S. DOOR / DRAWER PULLSTRAY COUNTER SUPPORT BRACKET;SEE MILLWORK NOTESNEW 3"GYPSUMWALL; FLUSHWITHHALLWAYWALLS6'-1012" ±V.I.F. (ALIGN W/ UNDERSIDE OF EXIST. HEADER)1'-112" ± (V.I.F.)EXISTING WALL2" TYP.1'-0"1'-0"1'-0"1'-0"1'-0"1'-112" ±V.I.F.3"1WALL TYPESCALE: 1" = 1'-0"FLOOR LINE5/8" TYPE "X" GYPSUM BOARD (EACH SIDE)3-5/8" METAL STUDS @ 16" O.C.BATT. SOUND INSULATIONNON-RATED WALLBASE PER FINISH SCHEDULECEILINGSEE R.C.P.LINE OF STRUCTURAL DECK OR SLAB ABOVEUSE MOISTURE RESISTANT GYPSUMBOARD FOR ALL WET AREASP.LAM. ON ALL EXPOSED SURFACES.312"112"138"138"138"138"138"DETAIL 2ATRAY SLIDE RAILSSOLID SURFACE TRAY SLIDEEXTENSION WITH (6) S.S. GLIDES OF1/4x1/4 SQUARE BAR STOCK ROUTEDINTO SURFACE NO MORE THAN 1/8"DEPTH. ADHERE WITH SILICONEADHESIVE. SEE DETAIL 2A.1/2" ACCESSORY PLATE AND (2) 3/8"DIA. EXPANSION ANCHORS, 3-1/2"EMBEDMENTADJUSTABLE SHELF3/4" PARTICLE BOARD; PLASTIC LAMINATEON ALL EXPOSED SURFACES - SEE ROOMFINISH SCHEDULE112"CHECK-OUT LINE SHELF CABINETSCALE: 1" = 1'-0"4A2011" TYP.BASE PER SCHEDULE6"4"312"1/2" SOLID SURFACE COUNTER WITH EASEDEDGES - SEE FINISH SCHEDULE FOR TYPE2'-10"BASE PER SCHEDULE3-5/8" METAL STUDS @ 16" O.C.IN-WALL BLOCKING AS REQ'DLINE BORE SYSTEM @ 1-1/4" O.C. BOTHSIDES TO RECEIVE HORIZONTAL SHELFS.S. DRAWER PULLTRAY COUNTER SUPPORT BRACKET;SEE MILLWORK NOTESSOLID SURFACE TRAY SLIDEEXTENSION WITH (6) S.S. GLIDES OF1/4x1/4 SQUARE BAR STOCK ROUTEDINTO SURFACE NO MORE THAN 1/8"DEPTH. ADHERE WITH SILICONEADHESIVE. SEE DETAIL 2A.1/2" ACCESSORY PLATE AND (2) 3/8"DIA. EXPANSION ANCHORS, 3-1/2"EMBEDMENTADJUSTABLE SHELF3/4" PARTICLE BOARD; PLASTIC LAMINATEON ALL EXPOSED SURFACES - SEE ROOMFINISH SCHEDULE2'-11"2'-3"112"CHECK-OUT LINE SHELF CABINETSCALE: 1" = 1'-0"5A2011" TYP.BASE PER SCHEDULE4"312"1/2" SOLID SURFACE COUNTER WITHEASED EDGES - SEE FINISH SCHEDULEFOR TYPE2'-10"BASE PER SCHEDULE3-5/8" METAL STUDS@ 16" O.C.IN-WALL BLOCKINGAS REQ'DLINE BORE SYSTEM @ 1-1/4"O.C. BOTH SIDES TO RECEIVEHORIZONTAL SHELF1/2" ACCESSORYPLATE AND (2) 3/8" DIA.EXPANSION ANCHORS,3-1/2" EMBEDMENTADJUSTABLE SHELF3/4" PARTICLE BOARD; PLASTICLAMINATE ON ALL EXPOSEDSURFACES - SEE ROOM FINISHSCHEDULE2'-4"INFILL PANEL OFMARINE-GRADE PLYWOOD ATENTIRE UNDERSIDE OFCOUNTER TO PROVIDECONTINUOUS FLUSHSURFACE (TYP.)112"CHECK-OUT LINE CASHIER COUNTERSCALE: 1" = 1'-0"7A2011" TYP.BASE PER SCHEDULE1/2" SOLID SURFACE COUNTER WITH EASEDEDGES - SEE FINISH SCHEDULE FOR TYPE2'-10"BASE PER SCHEDULE3-5/8" METAL STUDS @ 16" O.C.IN-WALL BLOCKING AS REQ'DTRAY COUNTER SUPPORT BRACKET;SEE MILLWORK NOTESSOLID SURFACE TRAY SLIDEEXTENSION WITH (6) S.S. GLIDES OF1/4x1/4 SQUARE BAR STOCK ROUTEDINTO SURFACE NO MORE THAN 1/8"DEPTH. ADHERE WITH SILICONEADHESIVE. SEE DETAIL 2A.1/2" ACCESSORY PLATE AND (2) 3/8"DIA. EXPANSION ANCHORS, 3-1/2"EMBEDMENT3/4" PARTICLE BOARD; PLASTICLAMINATE ON ALL EXPOSEDSURFACES - SEE ROOM FINISHSCHEDULE2'-11"FINISHED FLOOR2'-6"2'-0"SCRIBE AND CAULK CONTINUOUS BY GENERALCONTRACTORS.S. DOOR PULLSADJUSTABLE SHELF4"312"BASE PER SCHEDULE4"1" TYP.END SPLASH AT WALLLINE BORE SYSTEM @ 1-1/4" O.C. BOTHSIDES TO RECEIVE HORIZONTAL SHELFDINING AREA CABINET BASESCALE: 1" = 1'-0"8A2013/4" PARTICLE BOARD; PLASTIC LAMINATEON ALL EXPOSED SURFACES - SEE ROOMFINISH SCHEDULECAM LOCK AT EACH CABINET DOOR PAIRAND DRAWER (TYP.) - SEE MILLWORK NOTES;PROVIDE CATCH AT INACTIVE DOOR4'-6" A.F.F.(N.T.S.)P. LAM. SHELVES- SEE ROOM FINISHSCHEDULE; PROVIDE BLOCKING AS REQ'D.DINING AREA SHELF DETAILSCALE: 1" = 1'-0"9A2013"FINISHED FLOORMICROWAVE1'-4"MICROWAVE4" BACKSPLASH2'-0"2'-6"(N.T.S.)3"WOOD BLOCKING; CLEAT ALL 3 SIDES34" PLYWOOD WITH P. LAM ON EXPOSEDSURFACE1/2" SOLID SURFACE COUNTER WITH EASEDEDGES - SEE FINISH SCHEDULE FOR TYPE1138"558"10"1'-738"558"10"1'-838"558"558"10"1'-738"LINE BORE SYSTEM @ 1-1/4" O.C. BOTHSIDES TO RECEIVE HORIZONTALSHELVESFINISHED FLOOR3'-0"112"2'-8"4"312"3/4" PARTICLE BOARD COUNTERTOPWITH 1/4" CHAMFER; PLASTICLAMINATE (L1) ON ALL EXPOSEDSURFACES; USE BALANCE SHEETWHERE REQUIRED - SEE ROOMFINISH SCHEDULEBASE PER SCHEDULE1" TYPADJUSTABLE SHELFLINE BORE SYSTEM @ 1-1/4" O.C.BOTH SIDES TO RECEIVEHORIZONTAL SHELFSILVERWARE CABINET BASESCALE: 1" = 1'-0"11A2013/4" PARTICLE BOARD; PLASTICLAMINATE ON ALL EXPOSEDSURFACES - SEE ROOM FINISHSCHEDULESTAFF SIDECUSTOMER SIDE3"10"1'-078"(8) 4" DIAMETER HOLES W/ CYLINDERSILVERWARE STORAGE INSERTS1'-2"1'-778"1"APRON (BEHIND); SEE FINISH SCHED.FINISHED FLOOR3'-1"8"4"312"BASE PER SCHEDULE1" TYP.END CABINET BASESCALE: 1" = 1'-0"12A2013/4" PARTICLE BOARD; PLASTIC LAMINATEON ALL EXPOSED SURFACES - SEE ROOMFINISH SCHEDULE112"1/2" SOLID SURFACE COUNTER WITH EASEDEDGES - SEE FINISH SCHEDULE FOR TYPEEXISTING STAINLESSSTEEL SERVINGCOUNTER3'-0"FILLER PANEL TO PROVIDE FLUSHSURFACE UNDERNEATH S.S. COUNTEROVERHANG958"6"TYP.UPPER CABINETS OR STORAGE CABINET- SEE INTERIOR ELEVATIONS1'-4"METAL CORNER BEAD (TYP.)2"5/8" GYPSUM BOARD TYPE "X" ON3-5/8" METAL STUDS @16" O.C. (TYP.)CEILINGEL. = SEE R.C.P.EXISTING CONSTR.EL. = EXISTING"J" BEAD TO FINISH ROUGHDRYWALL ENDS (TYP.)SOFFIT DETAILSCALE: 1-1/2" = 1'-0"10A1021.CONTRACTOR TO VERIFY ALL DIMENSIONS BEFORE BEGINNING WORK. FABRICATE CASEWORK INSECTIONS AS NECESSARY TO FACILITATE HANDLING AND BUILDING ENTRY. ALL SUCH CASEWORKSECTIONS TO BE JOINED WITH SPLINES AND RV #315 TITE-JOINT FASTENERS.MILLWORK NOTES2.ALL CASEWORK AND MILLWORK FABRICATION AND MATERIALS TO EQUAL ARCHITECTURALWOODWORK INSTITUTE QUALITY STANDARDS "CUSTOM GRADE" EXCEPT PLASTIC LAMINATEAPPLICATION WHICH IS TO BE "PREMIUM GRADE".3.CASEWORK IS TO BE FLUSH OVERLAY CONSTRUCTION. USE SCRIBE ENDS WHERE CASEWORK ISEXPOSED. CAULK JOINTS TO ELIMINATE GAPPING BETWEEN DISSIMILAR MATERIALS, OR NEWCASEWORK AND EXISTING CONSTRUCTION (TYPICAL). USE STILES WHERE NECESSARY TO MOUNTHINGES TO ADJACENT DOORS.4.ALL CASEWORK CORES TO BE 3/4" PARTICLE BOARD EXCEPT AS NOTED.5.ALL BASE CABINETS KICKS TO BE 3/4" SOLID WOOD OR VENEER PLYWOOD.6.ALL INTERIOR SURFACE OF EXPOSED (OPEN) CABINETS SHALL BE PLASTIC LAMINATE TO MATCHEXTERIOR OF CABINET. INTERIOR SURFACES OF UNEXPOSED (CLOSED WITH DOORS, DRAWERS, ORPANELS) SHALL BE MELAMINE (WHITE) UNLESS OTHERWISE NOTED.8.BACKS OF PLASTIC LAMINATED SURFACES SHALL RECEIVE BALANCE SHEET.9.CABINET BACKS - USE PREFINISHED HARDBOARD (MELAMINE, ETC) WITH COLOR TO MATCH PLASTICLAMINATE CASEWORK. USE 1/4" HARDBOARD WITH PLASTIC LAMINATE AND BALANCE SHEET AT ALLCASEWORK BACKS THAT ARE EXPOSED.GENERAL CONTRACTOR IS TO PROVIDE BLOCKING IN WALLS FOR CASEWORK EVEN IF NOTSPECIFICALLY INDICATED ON DRAWINGS.11.12. CABINETRY HARDWARE: FOR ADDITIONAL INFORMATION REFER TO SPECIFICATIONS.PULLS - (US26D) BRUSHED CHROME, 4";HINGES - 165° OPENING (CONCEALED, SELF-CLOSING);SHELF SUPPORTS - 32 MM LINE BORE SYSTEM WITH HAFELE #282.04.739 (METAL CLIPS);LOCKS AND CATCHES - KENSTAN CAM LOCK (KEY REMOVABLE IN UNLOCKED POSITION) WITH IVESSBA3 ELBOW CATCH AT DOUBLE DOORS;TOUCH LATCH - EPCO #507 BLACK PLASTIC;DRAWER SLIDES - MEDIUM DUTY DRAWER SLIDE. FULL EXTENSION (ARCHITECT TO SELECT COLOR).13.SHELVES TO HAVE 3/4" CORE (TYPICAL TO 36"; >36" = 1" CORE.)10.STENCIL PRODUCT NAME AND COLOR NAME & NUMBER AT UNDERSIDE OF ALL COUNTERTOPS,INCLUDE DATE OF FABRICATION.14HARDWOOD NOSING OR HARDWOOD TRIM TO BE FINISHED WITH FOUR (4) COATS OFPOLYURETHANE. POLYURETHANE SHALL BE RUBBED WITH "PLASTIC WOOL" BETWEEN COATS TOOBTAIN A SMOOTH SURFACE ON THE LAST COAT.7.ALL EXPOSED SURFACES OF CASEWORK TO RECEIVE PLASTIC LAMINATE.ADJUSTABLE SHELVES HARDWARE: KV 82/182 SHELVING SYSTEM WITH HEAVY DUTY BRACKETS ANDSTANDARDS (COLOR: WHITE OR ALMOND EPOXY - ARCHITECT TO SELECT COLOR AND OPTIONALACCESSORIES REQUIRED DURING SUBMITTAL PROCESS).15.COUNTER SUPPORT BRACKET: ARCHITECTURAL DEPOT- 2"W X 8"D X 8"H BELLHAVEN COUNTERTOPSUPPORT BRACKET; STAINLESS STEELITEM #BKT08X08BES16.17.ALL DRAWERS SHALL HAVE FULL HEIGHT SIDES AND BACK, UNLESS NOTED OTHERWISE.18.CONTRACTOR TO PROVIDE RUBBER DOOR SILENCERS AT ALL DOOR AND DRAWERS.19.GROMMETS (2-3/4" INTERIOR DIAMETER TYPICAL UNLESS NOTED OTHERWISE); COLOR TBD.COORDINATE WITH COUNTER FINISH. QUANTITY T.B.D. (GROMMETS TO BE LOCATED IN FIELD BYOWNER).20.KEYBOARD TRAYS TO BE O.F.C.I. WITH MELAMINE FILLER/BLOCKING BY CASEWORK/MILLWORKSUPPLIER. COORDINATE WITH OWNER FOR KEYBOARD SPECIFICATIONS AND TEMPLATE.DETAILSA501BWSEAL:MARK DATEISSUE- - -PROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:15-053REKREK01/08/2016SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.CafeteriaCooley Dickinson Hospital30 Locust StreetNorthampton, MA 01061Renovation to:PROJECT: DOOR ELEVATIONSASEE SCHED.2"TYP.2"TYP.5"x20" TEMPERED VISIONPANEL IN PAINTED H.M.FRAMESEESCHED.10"6"TYP.2"TYP.KICK PLATEWINDOW ELEVATIONSBPUSH BARS ON SERVINGLINE SIDEW19'-812"7'-2"4"1'-11"3"4'-6"2"7'-0"2" TRIM4"10"1'-11"6"3'-5"4"2"2"2'-3"112"2'-3"112"2'-3"112"2'-3"DOOR SCHEDULEMARKLBLMATLDOORSIZEELEVHDWRDOOR FRAMELBLMATLTRANSITIONJAMBDETAILLFSGLAZHEADREMARKSG-234A-ALUM.3'-0"x 7'-0"x 1-3/4"A1/4" T-1EX.7A/A6016/A6011HARDWARE SCHEDULE1.1-1/2 PAIR BUTT HINGES, BALL BEARING1 - OFFICE LOCKSET WITH LEVER HANDLES1 - DOOR STOP, WALL OR FLOOR MOUNT1 - SET DOOR MUTES1 - STAINLESS STEEL KICKPLATE - 12"H1- HOLD-OPEN CLOSER2.(2) 3'-0"x 7'-0"x 1-3/4"DOOR NOTES1. ALL DOOR HANDLES SHALL BE OF LEVER TYPE MEETING CURRENT ADA STANDARDS, (ASNOTED IN THE HARDWARE SCHEDULE). DOOR HANDLES TO ROOMS CONSTITUTING A HAZARD(ELECTRICAL ROOMS, MECHANICAL ROOMS, SOILED UTILITY ROOMS, ETC.) SHALL BE LEVER TYPEWITH A KNURLED FINISH ON THE GRIP SURFACE.NOTE:2. ALL DOOR LEVERS SHALL REMAIN NON-RIGID AT LOCKED CONDITION, EXCEPT AS NOTED.3. ALL LOCKSETS & LATCHSETS SHALL BE OF MORTISE DESIGN.4. ALL HARDWARE FINISH SHALL BE BRUSHED STAINLESS STL. (US32D)5. ALL PRODUCTS SPECIFIED ON AN 'OR EQUAL' BASIS UNLESS OTHERWISE NOTED.6. PROVIDE REQUIRED POWER SUPPLY SYSTEMS FOR OPERATING ALL ELECTROMAGNETICLOCKS, ELECTROMECHANICAL LOCKS, ELECTRIC STRIKES, & MARLOK ELECTRONIC CYLINDERSYSTEMS. COORD. REQUIREMENTS W/E.C.7. ALL ELECTROMAGNETIC LOCKS, ELECTROMECHANICAL LOCKS, & ELECTRIC STRIKES SHALL BEOF THE 'FAIL SAFE' DESIGN, UNLOCKING WHEN THE FIRE ALARM IS ACTIVATED OR ELECTRICALPOWER IS INTERRUPTED.8. ALL STAINLESS STEEL KICKPLATES SHALL BE 2" LESS THAN DOOR WIDTH x 12" HIGH (TYPICAL -U.O.N.) AND SHALL BE MOUNTED 1" FROM THE BOTTOM OF THE DOOR; SEE SPECIFICATION.9. ALL HOLLOW METAL FRAMES SHALL BE SHOP WELDED UNLESS NOTED OTHERWISE.ABBREVIATIONSDOORDRHOLLOW METALHMINSULATED HOLLOW METALIHMKICKPLATE (HEIGHT")K(12)MTL.METALMINMINERAL COREPTD.PAINTEDSCWSOLID CORE WOODS.S.STAINLESS STEELSTL.STEELTITEMPERED INSULATEDV.I.F.VERIFY IN FIELDWD.WOODALUMINUM STOREFRONT SYSTEMALTTEMPERED1/4" WG1/4" WIRE GLASS1/4" T1/4" TEMPERED GLASS1" IG1" INSULATED GLASS3 - PAIR BUTT HINGES, BALL BEARING2 - ENTRANCE LOCKSET WITH EMERGENCY PUSH BAR (PUSH SIDE) AND LEVER HANDLE (PULLSIDE)- VERTICAL ROD EACH LEAF. TOP LATCH ONLY.2 - DOOR STOPS, WALL OR FLOOR MOUNT2 - SET DOOR MUTES2 - STAINLESS STEEL KICKPLATES - 12"H2 - HOLD-OPEN CLOSERSWINDOW SCHEDULEMARKR. O. SIZEELEVDETAILHEADREMARKSTYPE1/4" TEMPERED GLASS12/A601JAMB SILL12/A601 13/A601REMOVABLESTOREFRONTWINDOW SYSTEMW1G-234B B1/4"T 2-ALUM. 2-ALUM.9' 8 1/2"W x7'-2"H6/A6016/A601 6/A601 7B/A60110. ALL NEW DOORS SHALL BE CLEAR ANODIZED ALUMINUM TO MATCH STOREFRONT WINDOWSYSTEM. DOORS TO FIRE STAIR IN ROOM G-238 SHALL BE PAINTED PER FINISH SCHEDULE. ALLEXISTING OAK VENEER DOORS E.T.R.HOLLOW METAL FRAME - PAINT; SEE SPEC.(TYP.)CAULK CONT. (BOTH SIDES)2x WOOD BLOCKING (FIRE -RETARDANT)SEE FLOOR PLAN FOR WALL TYPE12"TYP.2"12"WALL ANCHORS & BASE CLIPSDOOR - SEE DOOR SCHEDULEDOOR HEAD / JAMB DETAILSCALE: 3" = 1'-0"6A601CAULK AND BACKER ROD AROUNDPERIMETER BOTH SIDES (TYP.)CLEAR ANODIZED ALUMINUMSTOREFRONT SYSTEM2"1/4" TEMPERED SAFETY GLASS2x WD. BLOCKING (FIRE -RETARDANT)SEE FLOOR PLAN FOR WALLTYPE412"1/4" TEMPERED SAFETYGLASS2"1/4" TEMPERED SAFETY GLASSSHIM AS REQUIREDCLEAR ANODIZED ALUMINUMSTOREFRONT SYSTEMCAULK AND BACKER ROD AROUNDPERIMETER BOTH SIDES (TYP.)SHIM AS REQUIREDCLEAR ANODIZED ALUMINUMSTOREFRONT SYSTEM412"412"412"STOREFRONT SYSTEMWINDOW HEAD / JAMB DETAILSCALE: 3" = 1'-0"12A601STOREFRONT SYSTEMWINDOW SILL DETAILSCALE: 3" = 1'-0"13A601STOREFRONT SYSTEMWINDOW MULLION DETAILSCALE: 3" = 1'-0"14A60114" ALUMINUM REVEALEXISTING QUARRY TILE TOREMAINVINYL TRANSITION STRIP; ALIGN WITH EDGEOF EXISTING TILE1/2"MAXIMUMUNDERCUTCLDOOR (SHOWN IN CLOSED POSITION) - SEEDOOR SCHEDULE; SEE SPEC. (TYP.)EXISTING RESILIENT FLOORINGDOOR TRANSITION DETAILSCALE: 6" = 1'-0"7AA601VINYL TRANSITION STRIPRESILIENT FLOORING - SEEROOM FINISH SCHEDULERESILIENT FLOORING -SEE ROOM FINISHSCHEDULE1/2"MAXIMUMUNDERCUTCLDOOR (SHOWN IN CLOSED POSITION) - SEEDOOR SCHEDULE; SEE SPEC. (TYP.)DOOR TRANSITION DETAILSCALE: 6" = 1'-0"7BA601DOOR & WINDOWSCHEDULESA601BWSEAL:MARK DATEISSUE- - -PROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:15-053REKREK01/08/2016SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.CafeteriaCooley Dickinson Hospital30 Locust StreetNorthampton, MA 01061Renovation to:PROJECT: FINISH MATERIALS KEYKEYMATERIAL MANUFACTURER SERIES NUMBER COLORG-234 SERVING LINEWALLCOVERINGPAINTWALLCOVERINGPAINTPAINTSTAIN & VARNISHQUARRY TILEVINYL PLANK FLOORINGACCENTVINYL BASEPAINTSTAIN & VARNISHROOM FINISH SCHEDULEROOM # ROOM NAMEFLOOR BASE WALLS DOOR TRIMREMARKSWESTSOUTHWALLCOVERINGPAINTEASTWALLCOVERINGNORTHETR,T1PAINTSEE FINISHES FLOOR PLAN ON SHEET AF101 AND ELEVATIONS ON SHEET A201 FOR PLACEMENT OF ACCENT PAINTS.SEE FINISHES FLOOR PLAN, SHEET AF101, FOR FLOORING LAYOUT & LOCATIONS. DIRECTION OF VINYL PLANKS SHALL BE EAST - WEST.GENERAL FINISH NOTESDCBAALL EXISTING TRIM (INCLUDING CHAIR RAILS, CROWN MOLDING, & FIREPLACE MANTLE) SHALL BE STRIPPED AND REFINISHED WITH PAINT P1. CHAIR RAIL AT NEW WALL IN CAFETERIA #G-238 SHALL MATCHEXISTING AND RECEIVE SAME PAINT (P1).7BOTH HORIZONTAL AND VERTICAL SURFACE OF NEW SOFFITS SHALL BE PAINTED P4.65432FINISH SCHEDULE NOTES1EFALL NEW DOORS SHALL BE CLEAR ANODIZED ALUMINUM TO MATCH STOREFRONT WINDOW SYSTEM.ALL VINYL BASE SHALL BE ROLLED GOODS.NATURAL CREATIONS- ARBORART TP075HAND CRAFTED NUTMEG (6"X48")B1 VINYL BASE - VINYL AREASV1 VINYL PLANKP1 PAINT - TRIM&BELOW CHAIR RAILP2 PAINT - WALLL1 PLASTIC LAMINATE- VERTICALSS1 SOLID SURFACE- COUNTERP3 NOT IN USEB1 P2 P2 P2 P2 N/AFLOORINGBASEWALLS / PAINTSURFACINGTS1 VINYL TRANSITION STRIPTRANSITIONST1 12X12 QUARRY TILE (O.F.C.I.)SEMI-GLOSS FINISHEGGSHELL FINISHP4 PAINT - ACCENT B4"G-236 CONFERENCE ROOM DG-237 CORRIDORG-238 CAFETERIAG-249 CONFERENCE/ DINING C (ALT. B)ARMSTRONG----284GANACHEJOHNSONITEBENJAMIN MOOREAF-365AMULETBENJAMIN MOOREAF-330SOLEILBENJAMIN MOORE2144-20EUCALYPTUS LEAFJOHNSONITETHE PORTION OF THE WALLS BELOW CHAIR RAILS SHALL ALSO BE PAINTED WITH P1 (AFTER REMOVAL OF EXISTING WALLCOVERING AND PREPPING/ PRIMING OF WALL, ), AS WELL AS ALL COLUMNS(EXCEPT INSETS TO BE P4).ALL EXISTING QUARRY TILE (FLOOR AND BASE) TO REMAIN; CLEAN AND REPAIR AS REQUIRED.V1QUARRY TILE BASEETRP1P1, P2 P1, P2 P1, P2 P1, P2V1EX. P1P2 P2 P2 P2ETRP1ETRETR ETRB1V1 P1, P2 P1, P2 P1, P2 P1, P2 P1 (FIRE DR) P1B1 P1, P2 P1, P2 P1, P2 P1, P2P1 FOR ALTERNATE B ONLYALTERNATE E: CLEAN & PAINT BOTH UNDERSIDE AND VERTICAL SURFACE OF EXISTING 2X2 ACT SOFFIT ABOVE NORTH WALL IN SERVING LINE (TILES AND GRID). PAINT SHALL BE P4.ALCOVES SHALL BE PAINTED P4.V1MATTEP5 PAINT - CEILING BENJAMIN MOOREOC-92MANNEQUIN CREAMREPLACEMENT FOR F.R.P. PANELS AT CONVEYOR SHALL BE FIBER REINFORCED LAMINATE PANELS (L3).L2 PLASTIC LAMINATE- ACCENTAPRON ACCENTS AT CASHIER CHECK-OUT MILLWORK SHALL BE L2; ALL OTHER MILLWORK LAMINATE SHALL BE L1.EX.EX.L3 PLASTIC LAMINATE- FRL PANELSEGGSHELL FINISH-WE706 TXSUMMER STRIPELAB DESIGNS--ROSEMARYCORIAN-D495K-18 (LINEARITY FINISH) COFFEE BEANWILSONART-VN705 SMCOCONUTLAB DESIGNS167FUDGE-BEAMS (BELOW CROWN MOLDING) SHALL BE PAINTED COLOR P4.MATCH EXISTING GRAYQUARRY TILE TO LINE OFMILLWORK EDGECORRIDORG-237CONFERENCEROOM DG-236SERVINGLINEG-234T.V.FIRESTAIRCONFERENCE/DINING CG-249G-235G-243G-235AG-233CONVEYORCAFETERIAG-238PLAN NORTHFINISHES FLOOR PLANSCALE: 3/16" = 1'-0"EXIST. TILE EXIST. VINYL EXIST. TILE VINYL PLANK EXIST. TILE VINYL PLANK VINYL PLANK EXIST. TILEVINYL PLANKEXIST. TILEEXIST. TILE VINYL PLANK VINYL PLANKEXIST. TILENEW CHAIR RAILTO MATCHEXISTINGPAINT P4PAINT P4PAINT P4PAINT P4PAINT P4PAINT P4PAINT P4PAINT P4ALTERNATE B: NEWFURNITURE ANDFINISHES TO MATCHFINISH SCHEDULEAF101BWSEAL:MARK DATEISSUE- - -PROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:15-053REKREK01/08/2016SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.CafeteriaCooley Dickinson Hospital30 Locust StreetNorthampton, MA 01061Renovation to:PROJECT: CORRIDORG-237CONFERENCEROOM DG-236SERVINGLINEG-234KITCHENG-225T.V.FIRESTAIRPPIZZADISPLAYTOASTDISPLAYCOCA- COLA FRIDGE ICE CREAM CONFERENCE/DINING CG-249G-310G-242G-235G-243G-235AG-233SERVINGCOUNTERMETAL COUNTER CONVEYORPROJECT AREACAFETERIAG-238CORRIDORG-237CONFERENCEROOM DG-236SERVINGLINEG-234KITCHENG-225T.V.FIRESTAIRPPIZZADISPLAYTOASTDISPLAYCOCA- COLA FRIDGE ICE CREAM CONFERENCE/DINING CG-249G-310G-242G-235G-243G-235AG-233SERVINGCOUNTERMETAL COUNTER CONVEYORPROJECT AREACAFETERIAG-238(DEMO) (ALT. D-DEMO)RELOCATED SECURITY CAMERA(DIRECTLY ABOVE CASH REGISTER)I.T. SERVER BOX RELOCATEDINSIDE BASE CABINET; WIRE TOT.V. THROUGH WALLRELOCATED T.V. WITH 1 12" SHALLOW T.V. BOXFLOOR383660386018DIGITAL MENU (SUSPENDED);POWER AND DATA AT BOXESIN SUSPENDED CEILINGALTERNATE D: NEW PENDANT LIGHTS OVERSALAD BAR; SEE SPEC, REMOVAL OF (1) 2X2LIGHTREPLACE (4) EXISTING 2X4SURFACE-MOUNTED LIGHTSWITH NEW 2X4SURFACE-MOUNTED LEDLIGHTS; SEE SPEC.REPLACE (5) EXISTING SURFACE-MOUNTED 1X4LIGHTS WITH NEW SURFACE-MOUNTED 1X4 LEDLIGHTS; SEE SPEC.DEMO 2X2 LIGHTALTERNATE F: REPLACE ALL(17) 2X2 LIGHTS IN RM #G-234WITH NEW L.E.D.; SEE SPEC.(TOTAL 16 IF 1 IS REMOVEDFOR ALT. D)181818186018LEGENDSINGLE POLE SWITCHSECURITY CAMERAPHONE SYSTEM OUTLETFIRE ALARM PULL STATIONFIRE ALARM HORNFIRE ALARM HORN/STROBECEILING - MOUNTED EXIT SIGNWALL - MOUNTED EXIT SIGNDUPLEX RECEPTACLE AT 18" OR HEIGHT INDICATEDCOMPUTER/ INTERNET OUTLETDOUBLE DUPLEX RECEPTACLE AT 18" OR HEIGHT INDICATEDCOMPUTER/PHONE OUTLETELECTRICAL NOTESGENERAL NOTES1. ANY EXISTING MECHANICAL, ELECTRICAL, PLUMBING AND/OR FIRE PROTECTION DEVICES(THERMOSTATS, OUTLETS, SWITCHES, PULL STATIONS, ETC.) WITHIN WALLS SCHEDULED FORDEMOLITION BUT REQUIRED TO REMAIN SHALL BE RELOCATED TO NEAREST ADJACENT WALL ASREQUIRED BY OWNERS, ARCHITECT AND / OR DESIGN/BUILD CONTRACTORS.LIGHT FIXTUREEMERGENCY LIGHTGENERAL NOTESA. THE PLANS ARE DIAGRAMMATIC IN NATURE AND THEIR INTENT IS TO SHOW THE BASICREQUIREMENTS OF THE SYSTEM. THE INSTALLER SHALL FURNISH ALL MATERIALS, FIXTURES,WIRING, DEVICES, SUPPORT, DISCONNECT SWITCHES, AND OTHER REQUIRED EQUIPMENT NOTSPECIFICALLY INDICATED HEREIN, AND LABOR FOR A COMPLETE AND OPERATING SYSTEM ASSPECIFIED HEREIN. THE INSTALLER IS RESPONSIBLE FOR OBTAINING AND PAYING FOR ANYNECESSARY PERMITS AND APPROVALS, AND ANY OTHER CHARGES OR FEES.B. ALL ELECTRICAL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE NATIONALELECTRICAL CODE (NFPA 70), AND THE THE MASSACHUSETTS ELECTRIC CODE.C. CONTRACTOR SHALL GUARANTEE ALL LABOR AND MATERIALS FOR A PERIOD OF ONE (1)YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION.WIRING2.A. ALL WIRING SHALL MATCH EXISTING BUILDING STANDARD UNLESS SPECIFICALLY INDICATEDOTHERWISE. ALL WIRING TO BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE & MASSELECTRIC CODE. ALL WIRING TO BE RUN CONCEALED. IN MOST CASE NEW LIGHTS SHOWN ARETO BE CONNECTED TO EXISTING CIRCUITS IN THE AREA.1. WIRING FOR CIRCUITS INDICATED TO BE CONNECTED TO THE EMERGENCY SYSTEMSHALL BE KEPT ENTIRELY INDEPENDENT OF OTHER WIRING AND SHALL NOT ENTER THESAME RACEWAY, BOX, CABINET, ETC. WITH OTHER WIRING. A SEPARATE WIRE ANDCONDUIT SYSTEM IS REQUIRED FOR THE EMERGENCY SYSTEM IDENTIFIED AS ANEMERGENCY SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE.3.RECEPTACLESA. ALL DUPLEX (QUADRAPLEX) RECEPTACLES TO BE MOUNTED 18" ABOVE FINISH FLOORUNLESS INDICATED OTHERWISE. RECEPTACLES TO BE HOSPITAL GRADE RATED FOR 20 AMPS120V.4.SWITCHESA. LIGHTING SWITCHES SHALL BE RATED FOR 20 AMP 120/277 VOLTS.B. INSTALL WALL SWITCHES 48 INCHES (ON CENTER) ABOVE FLOOR, OFF POSITION DOWN.6.SUPPORT REQUIREMENTSA. LIGHT FIXTURES TO BE SUPPORTED INDEPENDENT OF THE CEILING GRID SYSTEM. THEYSHALL BE SUPPORTED FROM THE BUILDING STRUCTURE WITH JACK CHAINS.B. RESUPPORT ALL EXISTING CONDUIT ABOVE THE WORK AREA.8.FIRESTOPPINGA. THE INTEGRITY OF FIRE-RATED WALLS AND FLOORS, WHERE PENETRATIONS ARE MADE FORTHE PASSAGE OF CONDUIT, CABLES, ETC., MUST BE MAINTAINED.1. ALL PENETRATIONS MUST BE SLEEVED AND FIRE STOPPED WITH MATERIALS THAT AREUL CLASSIFIED AND FACTORY MUTUAL APPROVED FOR USE IN APPLICABLE RATEDASSEMBLY.9.PANEL BALANCINGA. THE ELECTRICAL CONTRACTOR SHALL BALANCE ALL NEW & EXISTING CIRCUITS AS REQUIREDAT ALL NEW & EXISTING PANELS.5DATA / TELEPHONE OUTLETA. ALL DATA/ TELEPHONE OUTLETS TO CONSIST OF FLUSH OUTLET BOX WITH CONCEALED 3/4"METAL CONDUIT RUN TO ABOVE SUSPENDED CEILING.B. TELEPHONE/ DATA WIRING TO BE ACCOMPLISHED BY OWNERS CONTRACTOR.D. DO NOT SCALE DRAWINGS. SEE ARCHITECTURAL PLANS FOR EXACT LOCATIONS OFEQUIPMENT. ITEMS WHICH ARE NOT SPECIFICALLY LOCATED BY DIMENSION ON THEARCHITECTURAL PLANS SHOULD BE COORDINATED WITH THE ARCHITECT.E. ALL EQUIPMENT LISTED ON THE DRAWING IS SPECIFIED AS "OR APPROVED EQUAL" UNLESSINDICATED OTHERWISE. THE CONTRACTOR SHALL PROVIDE SUBMITTALS FOR ANY EQUIPMENTDIFFERENT FROM WHAT IS LISTED ON THE DRAWINGS FOR APPROVAL BY THE ARCHITECT PRIORTO INSTALLATION. FOR GENERAL EQUIPMENT WHICH IS NOT LISTED ON THE DRAWINGS,SUBMITTALS ARE REQUIRED AS OUTLINED IN THE SPECIFICATIONS.F. FOR EQUIPMENT FURNISHED BY "OTHERS", THE ELECTRICAL CONTRACTOR SHALL RUN THEPOWER LINES TO EQUIPMENT DISCONNECT SWITCHES AND MAKE FINAL CONNECTION TOEQUIPMENT UNLESS INDICATED OTHERWISE. THE CONTROLS FOR SAID EQUIPMENT SHALL BETHE RESPONSIBILITY OF "OTHERS" UNLESS NOTED OTHERWISE. COORDINATE LOADS WITHOTHER TRADES AND VERIFY SAME.MARKINGSA. MARK EXTERIOR OF ALL JUNCTION BOXES IN THE ELECTRICAL WIRING SYSTEM TO INDICATECIRCUIT NUMBER AND PANEL DESIGNATION OF ALL CIRCUITS CONTAINED WITHIN IT.7.10.DEMOLITIONA. REMOVE ALL ELECTRICAL ITEMS IN AREA TO BE RENOVATED. DISPOSE OF ALL ITEMS UNLESSSPECIFICALLY INDICATED TO BE REUSED.1. EMERGENCY LIGHTS AND EXIT LIGHTS TO BE REUSED.2. REMOVE ALL CIRCUITS BACK TO PANEL AND REMOVE CIRCUITS FROM PANEL.3. REMOVE EXISTING DIRECTORY FROM PANEL. PROVIDE NEW DIRECTORY TO REFLECTRENOVATED AREA CIRCUITS.18"18"PFFFIRE ALARM STROBEF2. ALL NEW AND REPLACEMENT LIGHT FIXTURES TO BE WIRED TO EXISTING CIRCUITING ANDSWITCHING.ELECTRICAL PLANE101BWSEAL:MARK DATEISSUE- - -PROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:15-053REKREK01/08/2016SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.CafeteriaCooley Dickinson Hospital30 Locust StreetNorthampton, MA 01061Renovation to:PROJECT:PLANNORTHELECTRICAL PLANSCALE: 1/4" = 1'-0"