Loading...
30 Locust BC care 2016-08-26DRAWING LIST A0.00 GENERAL NOTES, ABBREVIATIONS, LEGENDS A0.10 LIFE SAFETY A0.20 GROUND FLOOR EXISTING PLAN A0.21 BASEMENT EXISTING PLAN A0.30 PHASING PLAN A1.00 DEMOLITION PLAN GENERAL NOTES, KEYS, LEGENDS A2.00 FLOOR PLANS GENERAL NOTES, KEYS, LEGENDS A2.10 NEW WORK PLAN A2.11 NEW PLAN POWER COORDINATION A2.12 ROOF PLAN A4.00 FINISH PLAN GENERAL NOTES, KEYS, LEGENDS A4.10 SEAMING DIAGRAM A5.00 INTERIOR ELEVATIONS GENERAL NOTES, KEYS, LEGENDS A5.10 INTERIOR ELEVATIONS A5.11 INTERIOR ELEVATIONS A5.12 INTERIOR ELEVATIONS A6.00 REFLECTED CEILING GENERAL NOTES, KEYS, LEGENDS A9.10 DOOR HARDWARE, FRAME TYPES & DETAILS A9.20 CASEWORK MENU AND DETAILS A9.30 CUSTOM CASEWORK DETAILS - TECH WORKROOM A9.40 INTERIOR DETAILS A9.50 HARDWOOD DOOR DETAILS A9.60 LIAISON DESK DETAILS A10.00 FF&E PLAN AND SCHEDULES Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 MEP/FP Engineer Project Number: Date Issued: 30 LOCUST STREET NORTHAMPTON, MA 01060 COMPREHENSIVE BREAST CARE CENTER 185-01-00 8/15/16 COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER ISSUED FOR CONSTRUCTION S1.00 GENERAL NOTES, GROUND FLOOR PLAN S2.00 FRAMING DETAILS MEP-100 MEP GENERAL NOTES, ABBREVIATIONS, AND SYMBOL LISTS MEP-101 MEP DETAILS MEP-102 MEP SCHEDULES FPD-101 GROUND FLOOR FIRE PROTECTION DEMOLITION PLAN PD-100 BASEMENT PLUMBING DEMOLITION PLAN PD-101 GROUND FLOOR PLUMBING / FIRE PROTECTION DEMOLITION PLAN MGD-101 GROUND FLOOR MEDICAL GAS DEMOLITION PLAN FP-101 GROUND FLOOR FIRE PROTECTION PLAN PS-100 BASEMENT PLUMBING PLAN PS-101 GROUND FLOOR PLUMBING SANITARY AND VENT PLAN PW-101 GROUND FLOOR PLUMBING DOMESTIC WATER PLAN MG-101 GROUND FLOOR MEDICAL GAS PLAN P-400 PLUMBING / FIRE PROTECTION DETAILS HD-101 GROUND FLOOR HVAC DEMOLITION PLAN H-100 BASEMENT HVAC PLAN H-101 GROUND FLOOR HVAC DUCTWORK PLAN HP-101 GROUND FLOOR HVAC PIPING PLAN H-400 HVAC DETAILS ED-101 GROUND FLOOR ELECTRICAL DEMOLITION PLAN E-100 BASEMENT ELECTRICAL PLAN EL-101 GROUND FLOOR ELECTRICAL LIGHTING PLAN EP-101 GROUND FLOOR ELECTRICAL POWER PLAN ES-101 GROUND FLOOR ELECTRICAL SPECIAL SYSTEMS PLAN E-400 ELECTRICAL DETAILS T-101 GROUND FLOOR TECHNOLOGY PLAN PROJECT LOCATION PROJECT LOCATION: GROUND FLOOR FOR GC COORDINATION: ROOM G-105 SHEET 1.0 EQUIPMENT VENDOR DRAWINGS ROOM G-105 SHEET 2.0 EQUIPMENT VENDOR DRAWINGS ROOM G-105 SHEET 2.1 EQUIPMENT VENDOR DRAWINGS ROOM G-105 SHEET 2.2 EQUIPMENT VENDOR DRAWINGS ROOM G-105 SHEET 3.0 EQUIPMENT VENDOR DRAWINGS ROOM G-105 SHEET 3.1 EQUIPMENT VENDOR DRAWINGS ROOM G-105 SHEET 3.2 EQUIPMENT VENDOR DRAWINGS ROOM G-105 SHEET 3.3 EQUIPMENT VENDOR DRAWINGS ROOM G-105 SHEET 4.0 EQUIPMENT VENDOR DRAWINGS ROOM G-113 SHEET 1.0 EQUIPMENT VENDOR DRAWINGS ROOM G-113 SHEET 2.0 EQUIPMENT VENDOR DRAWINGS ROOM G-113 SHEET 2.2 EQUIPMENT VENDOR DRAWINGS ROOM G-113 SHEET 3.0 EQUIPMENT VENDOR DRAWINGS ROOM G-113 SHEET 3.1 EQUIPMENT VENDOR DRAWINGS ROOM G-113 SHEET 4.0 EQUIPMENT VENDOR DRAWINGS ROOM G-120 SHEET 1.0 EQUIPMENT VENDOR DRAWINGS ROOM G-120 SHEET 2.0 EQUIPMENT VENDOR DRAWINGS ROOM G-120 SHEET 2.1 EQUIPMENT VENDOR DRAWINGS ROOM G-120 SHEET 3.0 EQUIPMENT VENDOR DRAWINGS ROOM G-120 SHEET 3.1 EQUIPMENT VENDOR DRAWINGS ROOM G-120 SHEET 3.2 EQUIPMENT VENDOR DRAWINGS ROOM G-120 SHEET 4.0 EQUIPMENT VENDOR DRAWINGS ROOM G-120 SHEET 4.1 EQUIPMENT VENDOR DRAWINGS ROOM G-122 SHEET 1.0 EQUIPMENT VENDOR DRAWINGS ROOM G-122 SHEET 2.0 EQUIPMENT VENDOR DRAWINGS ROOM G-122 SHEET 2.1 EQUIPMENT VENDOR DRAWINGS ROOM G-122 SHEET 3.0 EQUIPMENT VENDOR DRAWINGS ROOM G-122 SHEET 3.1 EQUIPMENT VENDOR DRAWINGS ROOM G-122 SHEET 3.2 EQUIPMENT VENDOR DRAWINGS ROOM G-122 SHEET 4.0 EQUIPMENT VENDOR DRAWINGS ROOM G-122 SHEET 4.1 EQUIPMENT VENDOR DRAWINGS Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 & AND L ANGLE @ AT CENTERLINE Ø DIAMETER # POUND A/E ARCHITECT / ENGINEER AB ANCHOR BOLT ACBL ACCESSIBLE (ADA COMPLIANT) ACOUS ACOUSTICAL ACP ACOUSTICAL CEILING PANEL AD ACCESS DOOR ADA THE AMERICANS WITH DISABILITIES ACT ADBL ADAPTABLE (ADA COMPLIANT) ADDL ADDITIONAL ADH ADHESIVE ADJ ADJUSTABLE ADJC ADJACENT AF ACCESS FLOOR AFF ABOVE FINISHED FLOOR AFI AIR FLOW INDICATOR AGGR AGGREGATE AL ALUMINUM ALT ALTERNATE ANOD ANODIZED AP ACCESS PANEL ARCH ARCHITECT ASC ABOVE SUSPENDED CEILING ASPH ASPHALT AVAF AUDIO/VISUAL ALARM BD BOARD BLDG BUILDING BLKG BLOCKING BM BEAM BOT BOTTOM BUR BUILT-UP ROOFING CA CARD ACCESS CAB CABINET CB CASING BEAD CEM CEMENT CEMTS CEMENTITIOUS CER CERAMIC CG CORNER GUARD CGE CORNER END GUARD CHAN CHANNEL CHBD CHALKBOARD CHFR CHAMFER CJ CONSTRUCTION JOINT CL CENTER LINE CLG CEILING CLJ CONTROL JOINT CLO CLOSET CLR CLEAR CLRM CLASSROOM CMPST COMPOSITE CMU CONCRETE MASONRY UNIT CNTR COUNTER CO CASED OPENING COL COLUMN COMP COMPUTER CONC CONCRETE CONN CONNECTION CONSTR CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CORR CORRIDOR CPRS COMPRESSIBLE OR COMPRESSION CR CHAIR RAIL CRS COLD ROLLED STEEL CS CAST STONE CSK COUNTERSUNK CSMT CASEMENT CSWK CASEWORK CYL CYLINDER DBL DOUBLE DEMO DEMOLITION DEPT DEPARTMENT DET DETAIL DF DRINKING FOUNTAIN DG DECORATIVE GLASS DIA DIAMETER DIM DIMENSION DISP DISPENSER DIV DIVISION DMBD DRY MARKER BOARD DMPF DAMPPROOFING DN DOWN DO DITTO DOP DOOR OPENING DPG DECORATIVE PLASTIC GLAZING DS DOWNSPOUT DSP DRY STANDPIPE DST DOOR STOP DWG DRAWING DWR DRAWER E EAST EA EACH EIFS EXTERIOR INSULATION & FINISH SYSTEM EL ELEVATION ELAST ELASTOMERIC ELEC ELECTRIC ELEV ELEVATOR EMER EMERGENCY ENCL ENCLOSURE ENGR ENGINEER ENTR ENTRANCE EO EMERGENCY POWER EP ELECTRICAL PANEL EPDM ETHYLENE PROPYLENE DIENE MONOMER EPRF EXPLOSION PROOF EQ EQUAL EQUIP EQUIPMENT ESCAL ESCALATOR EW EACH WAY EWC ELECTRIC WATER COOLER EXC EXCAVATE EXH EXHAUST EXP EXPANSION EXIST EXISTING EXT EXTERIOR F/F FACE TO FACE FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL FB FLAT BAR FCO FLOOR CLEAN OUT FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FDN FOUNDATION FEC FIRE EXTINGUISHER CABINET FE FIRE EXTINGUISHER FGL FIBERGLASS FHC FIRE HOSE CABINET FHP FULL HEIGHT PARTITION FH FULL HEIGHT FIN FINISH FL FLASHING FLR FLOOR OR FLOORING FLUOR FLUORESCENT FOC FACE OF CONCRETE FOF FACE OF FINISH FOM FACE OF MASONRY FOS FACE OF STUD FPRF FIREPROOFING FS FULL SIZE FSH FIRE SPRINKLER HEAD FSTP FIRESTOPPING FT FOOT OR FEET FTG FOOTING FURN FURNITURE FURR FURRING FUT FUTURE G GAS GA GAGE GALV GALVANIZED GB GRAB BAR GEN GENERATOR GFRC GLASS FIBER REINFORCED CONCRETE GFRG GLASS FIBER REINFORCED GYPSUM GL GLASS GLMU GLASS MASONRY UNIT GMMU GLASS MESH MORTAR UNIT GND GROUND GR GRADE GRL GRILLE GRTG GRATING GSKT GASKET GT GROUT GVL GRAVEL GWB GYPSUM WALL BOARD GYP GYPSUM HB HOSE BIBB HC HOLLOW CORE HDBD HARDBOARD HDWD HARDWOOD HDWE HARDWARE HGR HANGER HGT HEIGHT HM HOLLOW METAL HMD HOLLOW METAL DOOR HNDRL HANDRAIL HO HOLD OPEN HORIZ HORIZONTAL HPT HIGH POINT HR HOUR HSAFD HORIZONTAL SLIDING ACCORDION FIRE DOOR HVAC HEATING, VENTILATION, AIR CONDITIONING HYDR HYDRAULIC ID INSIDE DIAMETER IF INSIDE FACE IN INCH OR INCHES INSUL INSULATION INTR INTERIOR IWH INSTANTANEOUS WATER HEATER JAN JANITOR JST JOIST JT JOINT KIT KITCHEN KO KNOCKOUT KOP KNOCKOUT PANEL KPL KICK PLATE L LEFT LAB LABORATORY LAD LADDER LAM LAMINATION LAV LAVATORY LB POUND LBL LABEL LF LINEAR FOOT LG LENGTH LG LENGTH LH LEFT HAND LHR LEFT HAND REVERSE LIB LIBRARY LIN LINEAR LKR LOCKER LLH LONG LEG HORIZONAL LLV LONG LEG VERTICAL LNTL LINTEL LONG LONGITUDINAL LP LIGHTPROOF LPT LOW POINT LT LIGHT LTWT LIGHTWEIGHT LTG LIGHTING LVR LEVER OR LOUVER MACH MACHINE MAINT MAINTENANCE MAS MASONRY MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MED MEDIUM MEMB MEMBRANE MET METAL MEZZ MEZZANINE MFG MANUFACTURER MH MANHOLE MIN MINIMUM MIR MIRROR MISC MISCELLANEOUS ML METAL LATH MLDG MOLDING MLWK MILLWORK MO MASONRY OPENING MTD MOUNTED MTR MORTAR MULL MULLION MVBL MOVABLE N NORTH NA NOT APPLICABLE NAT NATURAL NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NTS NOT TO SCALE OA OVERALL OC ON CENTER OD OUTSIDE DIAMETER OF OUTSIDE FACE OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED OFF OFFICE OPNG OPENING OPP OPPOSITE OT ELECTRICAL OUTLET OXY OXYGEN PB PANIC BAR PERF PERFORATED PERIM PERIMETER PERP PERPENDICULAR PGBD PED BOARD PL PLATE PLAM PLASTIC LAMINATE PLAS PLASTIC PLBG PLUMBING PLYWD PLYWOOD PNEU PNEUMATIC PNL PANEL PNT PAINT PNTD PAINTED POL POLISHED POLY POLYETHYLENE PR PAIR PRCST PRECAST PREFAB PREFABRICATED PREFIN PREFINISHED PTD PAPER TOWEL DISPENSER PTN PARTITION PTR PAPER TOWEL RECEPTACLE PVG PAVING QT QUARRY TILE QTY QUANTITY QUAL QUALITY R RISER RAD RADIUS RBR RUBBER RD ROOF DRAIN REC RECESSED REF REFERENCE REFR REFRIGERATOR REG REGISTER REINF REINFORCED OR REINFORCING REM REMOVEABLE REQD REQUIRED RESIL RESILIENT RFG ROOFING RH RIGHT HAND RHR RIGHT HAND REVERSE RLG RAILING RM ROOM RO ROUGH OPENING RV ROOF VENT RWL RAIN WATER LEADER S SOUTH SC SOLID CORE SCHED SCHEDULE SCRN SCREEN SD SOAP DISPENSER SECT SECTION SGL SINGLE SHR SHOWER SHT SHEET SHTHG SHEATHING SHV SHELVING SIM SIMILAR SK SINK SLV SLEEVE SM SHEET METAL SND SANITARY NAPKIN DISPENSER SNR SANITARY NAPKIN RECEPTACLE SPEC SPECIFICATION SQ SQUARE SSK SERVICE SINK SSP SOLID SURFACE POLYMER SST STAINLESS STEEL ST STREET STA STATION STC SOUND TRANSMISSION CLASS STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURAL SUSP SUSPENDED SYM SYMBOL SYMM SYMMETRICAL SYS SYSTEM T THERMOSTAT T&B TOP AND BOTTOM T&G TONGUE AND GROOVE TB TOWEL BAR TBM TOP OF BEAM TC TOP OF CONCRETE TD TEL / DATA TEL TELEPHONE TEMP TEMPORARY TER TERRAZZO TF TOP OF FOOTING TFF TOP OF FINISHED FLOOR THK THICKNESS THRES THRESHOLD THRU THROUGH TKBD TACKBOARD TMPD TEMPERED TOL TOLERANCE TP TOP OF PAVEMENT TPH TOILET PAPER HOLDER TS TACKABLE SURFACE TSL TOP OF SLAB TST TOP OF STEEL TV TELEVISION TW TOP OF WALL TYP TYPICAL U/C UNDER COUNTER UNEX UNEXCAVATED UNFIN UNFINISHED UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY UR URINAL UV ULTRAVIOLET VAC VACUUM VAF VISUAL ALARM VCT VINYL COMPOSITION TILE VERT VERTICAL VEST VESTIBULE VIF CONTRACTOR TO VERIFY IN FIELD VNR VENEER VR VAPOR RETARDER W WEST W/ WITH W/O WITHOUT WC WATERCLOSET WD WOOD WLD WELDED WSCT WAINSCOT WT WEIGHT WTRPRF WATERPROOFING WWF WELDED WIRE FABRIC CL 1 A1.01 SIM A1.01 1 SIM TOP OF SLAB ELEV = 100'-0" WINDOW / LOUVER SYMBOL DOOR MARK ELEVATION / LEVEL MARKER DATUM POINT ELEV = 100'-0" 1 View Name 1/8" = 1'-0" 1 2 3 4 A5.01 1 A1.01 SIM 1 A1.01 SIM 1 A1.01 SIM ACCESSIBILITY CLEARANCES REVISION SYMBOL ACCESSIBILITY SYMBOL BUILDING SECTION WALL SECTION DETAIL PLAN / SECTION DETAIL ELEVATION INTERIOR ELEVATION EXTERIOR SCALE: 1 View Name 1/8" = 1'-0"A1.01 VIEW NAME: PLAN, SECTION, ELEVATION, DETAILS VIEW NAME WITH REFERENCE COLUMN GRIDS PARTITION SYMBOL FN-00FURNITURE SYSTEM SYMBOL CURTAIN WALL PANEL SYMBOL EQUIPMENT SYMBOL # ROOM TAG /1 A1.01MATCH LINE CEILING TYPE/HT. ROOM NUMBER FINISH KEY APPROX ROOM AREA SHEET REFERENCE CEILING TYPE CEILING HEIGHT EQUIP. NUMBER PARTITION TYPE PANEL TYPE WINDOW / LOUVER MARK COLUMN NUMBER FURNITURE NUMBER CASEWORK TAG CASEWORK TYPE 1 A5.01 COLUMN LETTER CEILING WALL BASE FLOOR R 2 ' - 6 "FINISH TAG 1 001M 12'-6" TYPE EQ-00 PL X1 Room Name 101 F B W C 123 SF WIN X # 1541-A ROOM # - PRIMARY, SECONDARY, ECT. OVERHEAD (OVER COUNTER AND SOFFITS) CALLOUT BREAK LINE GRID LINE BELOW OR BEYOND (UNDERCOUNTER AND FOOTINGS) SCOPE OF WORK CASED OPENING PAIR TYPICAL DOOR DOOR WITH SIDELIGHT VARYING LEAF SLIDING DOUBLE ACTING TYPICAL WINDOW EXISTING TO REMAIN EXISTING TO BE REMOVED EXISTING WALL NEW WALL DEMOLISHED WALL ALUMINUM WOOD FINISH EXISTING BUILDINGS STEEL CONCRETE EARTH RIGID INSULATION RUBBER SAND GYPSUM BOARD INSULATION CMU Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION 1/4" = 1'-0"8/15/2016 9:47:27 AMA0.00 185-01-00 8/15/16 GENERAL NOTES, ABBREVIATIONS, LEGENDS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER ABBREVIATIONS SYMBOLS LINE TYPES DOORS / WINDOWS / WALLS MATERIALS Issuance Schedule Number Date Description DN UP FECFDVCDOWN 23R UP 23R DN. 23RWFECFDVC SCOPE OF WORK MAX DISTANCE TRAVELED 120'-0"TWO HOUR FIRE SEPARATION ASSEMBLY WITH 90 MINUTE OPENING PROTECTED EGRESS ROUTE (TRAVEL DISTANCE) ONE HOUR FIRE SEPARATION ASSEMBLY WITH 45 MINUTE OPENING PROTECTED EGRESS STAIR MAINTAIN 2 HOUR CONSTRUCTION SMOKE PARTITION ASSEMBLY WITH 20 MINUTE OPENING PROTECTED. (NFPA 101) ELEVATOR MAINTAIN 2 HOUR CONSTRUCTION SHAFT MAINTAIN 2 HOUR CONSTRUCTION CODE REVIEW BASED ON MASSACHUSETTS 8TH EDITION BASE CODE: MASSACHUSETTS AMENDMENTS TO THE INTERNATIONAL BUILDING CODE 2009, AND MASSACHUSETTS AMENDMENTS TO THE INTERNATIONAL EXISTING BUILDING CODE 2009. SCOPE RENOVATION TO AN EXISTING SPACE TO CREATE A BREAST CARE CENTER. THE SPACE WAS PREVIOUSLY CLASSIFIED AS BUSINESS (B) OCCUPANCY, AND WILL REMAIN BUSINESS (B) FOLLOWING THIS PROJECT. EXTERIOR WALLS, EGRESS STAIRS, ELEVATORS AND COMMON CORRIDORS ARE TO REMAIN UNCHANGED AND ARE OUTSIDE THE SCOPE OF THIS PROJECT. CLASSIFICATION WORK AREA CLASSIFICATION OF WORK: ALTERATIONS - LEVEL 1 (IEBC CHAPTER 6) THE EXISTING BUILDING OR PORTIONS THEREOF SHALL NOT BE ALTERED SUCH THAT THE BUILDING BECOMES LESS SAFE THAN ITS EXISTING CONDITION, UNLESS THE PORTION ALTERED CONFORMS TO THE REQUIREMENTS OF 780 CMR. USE GROUP: BUSINESS (B) CONSTRUCTION TYPE: SINCE THE PROJECT DOES NOT INCLUDE A CHANGE OF USE OR ADDITION, THE PROPOSED WORK DOES NOT TRIGGER COMPLIANCE WITH HEIGHT AND AREA LIMITATIONS OR MINIMUM CONSTRUCTION TYPE. THEREFORE, THE RENOVATION IS ONLY REQUIRED TO MAINTAIN AND BE CONSISTENT WITH THE EXISTING CONSTRUCTION TYPE. FIRE RESISTANCE RATINGS: THE PROJECT DOES NOT INCLUDE THE ALTERATION OR INSTALLATION OF ANY NEW BUILDING ELEMENTS THAT REQUIRE A FIRE RESISTANCE RATING. THIS INCLUDES THE NEW CORRIDOR WALLS, AS THE BUILDING IS PROVIDED WITH SPRINKLER PROTECTION THROUGHOUT (TABLE 1018.1). THEREFORE NO FURTHER UPGRADES ARE TRIGGERED BY THE PROPOSED WORK. VERTICAL OPENINGS BECAUSE THE BUILDING IS PROVIDED WITH SPRINKLER PROTECTION THROUGHOUT, EXISTING UNPROTECTED VERTICAL FLOOR OPENINGS ARE NOT REQUIRED TO BE ENCLOSED PER IEBC 703.2.1 EX. 5.2. NEW VERTICAL OPENINGS ARE REQUIRED TO COMPLY WITH 780 CMR 708.2. INTERIOR FINISHES THE INTERIOR FINISH OF WALLS AND CEILINGS IN THE WORK AREA MUST COMPLY WITH THE CODE REQUIREMENTS FOR NEW CONSTRUCTION (IEBC 703.4). MEANS OF EGRESS MEANS OF EGRESS THROUGHOUT THE WORK AREA ARE REQUIRED TO COMPLY WITH CHAPTERS 6 & 7 OF THE EXISTING BUILDING CODE; THE REMAINING PORTIONS OF THE BUILDING MUST MAINTAIN OR IMPROVE THEIR CURRENT LEVEL OF EGRESS (IEBC 6.04.1 & 705.1). -ALL ROOMS OR SPACES WITH A TRAVEL DISTANCE OVER 75 FEET OR WITH AN OCCUPANT LOAD GREATER THAN 50 MUST BE PROVIDED WITH TWO REMOTE EGRESS DOORS (IEBC 705.4.1.1). -THE WORK AREA EGRESS DOORS ARE NOT REQUIRED TO SWING IN THE DIRECTION OF EGRESS TRAVEL SINCE THERE ARE FEWER THAN 50 OCCUPANTS (780 CMR 1008.1.2). PANIC HARDWARE IS NOT REQUIRED (780 CMR 1008.1.10). -IN THE WORK AREA, THE MAXIMUM DEAD-END CORRIDOR LENGTH IS 70 FEET (IEBC 705.6 EX. 3). NOTE: NO DEAD END CORRIDORS IN THE WORK AREA EXCEED 35 FEET. -SINCE THE PROJECT DOES NOT INCLUDE AN INCREASE IN THE NUMBER OF OCCUPANTS OR A REDUCTION IN THE AVAILABLE EGRESS CAPACITY, THE EXISTING MEANS OF EGRESS CAPACITY IS ASSUMED TO BE ADEQUATE. ENERGY CODE PROVISIONS FOR EXISTING BUILDINGS THE BUILDING IS SUBJECT TO THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) INCLUDING THE AMENDMENTS CONTAINED IN 780 CMR CHAPTER 13. LEVEL 2 ALTERATIONS TO EXISTING BUILDINGS ARE PERMITTED WITHOUT REQUIRING THE ENTIRE BUILDING TO COMPLY WITH THE ENERGY REQUIREMENTS OF THE IECC. THE NEW ELEMENTS SHALL CONFORM TO THE ENERGY REQUIREMENTS OF THE IECC AS THEY RELATE T NEW CONSTRUCTION ONLY (IEBC 711.1). Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION As indicated 8/15/2016 9:47:28 AMA0.10 185-01-00 8/15/16 LIFE SAFETY COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER SCALE: 1" = 20'-0"1 GROUND FLOOR - LIFE SAFETY LIFE SAFETY LEGEND LIFE SAFETY NOTES Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 DN UP FECFDVCDOWN 23R UP 23R DN. 23R 700 SF ON-CALL 64 FD FECMGAPMGCV FDVCFECMGCVFDVC EXISTING TRANSPORT STORAGE G12 EXISTING ED ADMIN CLINICAL G13 EXISTING STORAGE G14 ELEVATORELEVATORELEVATOR EXISTING ED MEN'S LOCKERS G15 EXISTING ED WORK & LOCKERS EXISTING ED DOCTOR LOUNGE G06 EXISTING ED CONF ROOM G05 EXISTING OFFICE EXISTING STORAGE EXISTING OFFICE G16 EXISTING LINEN EXISTING LINEN EXISTING ED ADMIN G04 EXISTING OFFICE EXISTING EMERG MGMT STORAGE G03 EXISTING ED STORAGE G02 EXISTING OFFICE G01A EXISTING LOCKER ROOM G01 STAIR EXISTING ED LOCKER ROOM G20 EXISTING ED DR ON CALL SLEEP G19 EXISTING VEST. EXISTING EVS HSK G18 EXISTING OFFICE G17 CAFE PUBLIC TOILETS RADIOLOGY WATER DISPENSER EMERGENCY DEPARTMENT MAIN ENTRANCE AT GRADE CLEARLY MARKED SCOPE OF WORK CLASSROOM CONFERENCE ROOM Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION 1/16" = 1'-0"8/15/2016 9:47:29 AMA0.20 185-01-00 8/15/16 GROUND FLOOR EXISTING PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER Issuance Schedule Number Date Description MGCVx x x x x x x x xxx x xSHARPSPYXISPAT MONILL BOXPAT MON PAT MONDEFIBCLOCK DEFIBCLOCK PRINTER CLOCK CLOCK CLOCK SHAR P S PYXISRESUS CARTPA T MO NILL BOXPA T MO N PA T MO N DEFIB RESUS CARTCLOC K DEFIB CLO CK PRINTER CLO CK CLO CK CLO CK UP UP RAMP UP 1:12 SLOPE MAX. TYP.RAMP UP1:12 SLOPE MAX. TYP.MECHANICAL SPACE LOADING DOCK Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION 1/16" = 1'-0"8/15/2016 9:47:30 AMA0.21 185-01-00 8/15/16 BASEMENT EXISTING PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 7 8 910 1112131415 16 17 18 19 20 21 22 23 25 26 27 28 SCOPE OF WORK RADIOLOGIST WORKROOM G-124 LARGE MAMMOGRAPHY G-120 CLEAN WORK AREA G-126A INTERVIEW 2 G-117 PATIENT CHANGING ROOM 3 G-111C PATIENT CHANGING ROOM 1 G-111D PATIENT CHANGING ROOM 2 G-111B STAFF TOILET G-130A EXAM 2 G-107 SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A BONE DENSITY G-113 GOWNED SUB-WAITING G-110 MAMMOGRAPHY G-122 NURSE STATION G-126 STAFF BREAK ROOM G-123 ULTRASOUND G-121 STRETCHER WAITING G-127 OFFICE G-108 EXAM 1 G-106 STEREOTACTIC G-105 NAVIGATOR'S OFFICE G-116 INTERVIEW 1 G-118 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B SUB WAITING G-119 PATIENT TOILET G-109 LIAISON G-114C CORRIDOR G-115C CORRIDOR G-115B CORRIDOR G-111 CORRIDOR G-115A CORRIDOR G-128 CORRIDOR G-119B SUB WAITING PATIENT TOILET G-119A MEN'S CHANGING & WAITING G-114 MAINTAIN ACCESS MAINTAIN ACCESS SECONDARY ENTRANCE PROPOSED CONSTRUCTION BARRIER INTERIM ENTRANCE & PROPOSED CONSTRUCTION BARRIER GC TO COORDINATE SCOPE OF WORK SUCH THAT THE CONSTRUCTION BARRIER IS IN PLACE FOR NO MORE THAN ONE MONTHMIN5'-0"PRIMARY ENTRANCE PROPOSED CONSTRUCTION BARRIER 1. WORK WITHIN PHASING AREA (BEHIND PROTECTION BARRIER) TO BE COMPLETED DURING NORMAL HOURS UNLESS INDICATED OTHERWISE ON DRAWINGS. 2. ALL WORK OUTSIDE PHASING AREA TO BE COMPLETED DURING OFF-HOURS (NIGHTS AND WEEKENDS) 3. ALL WORK OUTSIDE PHASING AREA ON THE FLOOR ABOVE OR BELOW, TO BE COMPLETED DURING OFF HOURS (NIGHTS AND WEEKENDS) 4. ALL SHUTDOWNS TO BE COMPLETED DURING OFF-HOURS (NIGHTS AND WEEKENDS). 5. ALL SCHEDULING OF WORK SHALL BE COORDINATED WITH THE CLIENT AND/OR AUTHORIZED REPRESENTATIVE/PROJECT MANAGER. Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION 1/4" = 1'-0"8/15/2016 9:47:31 AMA0.30 185-01-00 8/15/16 PHASING PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER PHASING NOTES Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 7 8 910 1112131415 16 17 18 50 50 50 50 50 5050 50 5050 50 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 1010 41 41 41 50 41 41 41 41 41 41 50 41 41 41 41 41 41 41 41 01 01 41 41 06 06 06 06 06 01 01 01 01 01 01 01 01 01 2020 20 20 20 20 20 20 2020 20 30 30 30 30 30 30 30 30 30 30 303030 30 20 71 71 14 20 30 06 42 42 01 ELEVATORELEVATORELEVATOR EXISTING EMERG MGMT STORAGE G03 EXISTING ED STORAGE G02 EXISTING OFFICE G01A EXISTING LOCKER ROOM G01 STAIR EXISTING ED LOCKER ROOM G20 EXISTING ED DR ON CALL SLEEP G19 EXISTING VEST. EXISTING EVS HSK G18 EXISTING OFFICE G17 14 01 02 02 02 02 02 02 02 02 02 02 02 02 02 02 0202 02 02 20 42 20 30 01 SCOPE OF WORK 19 20 21 22 23 25 26 27 28 02 02 02 10 10 10 50 41 50 50 01 30 10 41 50 01 50 50 41 50 01 01 01 01 50 50 5041 10 01 01 01 50 01 10 10 41 20 30 20 30 20 30 20 30 20 30 20 30 20 30 20 20 20 30 01 01 01 01 01 10 01 0101 01 01 0110 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 EXISTING OFFICE G16 STORAGE OFFICE EXISTING ED CONF ROOM G05 EXISTING ED MEN'S LOCKER G15 EXISTING STORAGE G14 EXISTING ED ADMIN CLINICAL G13 41 63 63 63 10 63 63 63 63 63 63 09 20 30 42 64 64 64 42 42 64 64 02 02 02 02 64 02 02 10 10 64 02 42 64 64 64 64 42 10 414141 64 41 01 64 64 64 64 64 14 01 64 64 42 42 41 50 41 41 64 64 64 64 42 09 64 64 64 64 41 41 41 64 64 64 64 64 64 64 6464 42 42 42 42 42 01 01 01 01 01 01 01 01 01 01 0101 01 01 01 01 01 01 01 01010101 01 0101 01 01 01 01 01 01 01 01 01 0101 01 01 01 01 0101 01 01 01 01 01 01 01 01 01 01 01 31 31 31 64 64 01 14 41 64 10 01 64 10 10 10 01 64 64 64 10 64 01 01 64 20 302030 EXTENT OF DEMO 01 10 01 01 64 64 01 01 64 64 42 20 30 10 10 64 64 64 01 42 01 02 05 0505 0505 05 05 02 05 05 05 05 05 05 05 05 05 05 09 09EXTENT OF DEMOEXTENT OF DEMO 30 20 30 27' - 0" EXTENT OF FLOOR DEMO 90 90 91 1. SCOPE OF WORK LINE GENERALLY INDICATES THE AREA OF GREATEST IMPACT DURING RENOVATIONS. EXISTING AREAS OUTSIDE THE SCOPE OF WORK LINE THAT ARE DISTURBED IN ORDER TO COMPLETE THIS AREA ARE CONSIDERED TO BE PART OF THE SCOPE OF WORK WHETHER INDICATED SPECIFICALLY OR NOT. CONTRACTOR SHALL ALLOW FOR REMOVAL AND REPLACEMENT OF EXISTING FINISHES OUTSIDE THE SCOPE OF WORK LINE IN ORDER TO COMPLETE THE WORK. 2. SEE HOURS OF WORK REQUIREMENTS AND COORDINATE DEMOLITION ACTIVITIES ACCORDINGLY. 3. REFER TO ALL OTHER CONSULTANT AND VENDOR DRAWINGS AND SPECIFICATIONS FOR EXTENT AND REQUIREMENTS OF REMOVAL/SALVAGE/RELOCATION OF STRUCTURAL, PLUMBING/FIRE PROTECTION, MECHANICAL AND ELECTRICAL ITEMS. COORDINATE WITH ALL ASSOCIATED TRADES. 4. REFER TO DIV. 01 SECTION "CUTTING AND PATCHING" FOR REQUIREMENTS RELATED TO CUTTING AND PATCHING DUE TO DEMOLITION ACTIVITIES. 5. REFER TO DEMOLITION SPECIFICATION (DIVISION 01) FOR REQUIREMENTS RELATED TO DEMOLITION ACTIVITIES. 6. DISPOSE OF ALL DEMOLITION ITEMS IN ACCORDANCE WITH PROJECT SPECIFICATIONS. 7. REMOVE ALL ITEMS SHOWN AS DASHED LINES ON THE DEMOLITION DRAWINGS, INCLUDING ALL ASSOCIATED FITTINGS AND ACCESSORIES ASSOCIATED WITH ITEM(S) BEING REMOVED. 8. DEMOLITION KEYNOTES NOT SPECIFICALLY TAGGING AN INDIVIDUAL ITEM (NO LEADER ARROW) REFER TO ALL ITEMS WITHIN THE ROOM OR AREA IN WHICH THE NOTE IS LOCATED. 9. WHERE A PARTITION IS SHOWN TO BE DEMOLISHED, CONTRACTOR TO REMOVE ALL WALL MOUNTED FIXTURES/FITTINGS/EQUIPMENT. 10. FIRE RATINGS TO BE MAINTAINED AT ALL RATED ASSEMBLIES AT ALL TIMES. 11. FOR THE PURPOSES OF A COMPLETE SCOPE OF WORK THE CONTRACTOR IS TO ASSUME THAT ALL EXISTING WALLS TO BE DEMOLISHED THAT ARE GREATER THAN 8" THICK ARE CHASE WALLS, CONTINUOUS TO ADJACENT FLOORS AND WILL REQUIRE PATCHING. 12. RELOCATION OF ALL EQUIPMENT TO BE COORDINATED WITH OWNER. 13. PROVIDE TEMPORARY SUPPORTS FOR PORTION OF DEMOLISHED WALLS TO REMAIN. Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION 1/4" = 1'-0"8/15/2016 9:47:32 AMA1.00 185-01-00 8/15/16 DEMOLITION PLAN GENERAL NOTES, KEYS, LEGENDS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER SPECIFIC DEMOLITION NOTES 01 REMOVE PORTION OF GYPSUM BOARD PARTITION AS INDICATED. 02 REMOVE PORTION OF TILE FACED GYPSUM BOARD PARTITION. 05 REMOVE LAYERS OF GYPSUM BOARD AND/OR PLASTER LATH, EXISTING PARTITION FRAMING TO REMAIN. 06 REMOVE COLUMN ENCLOSURE. 09 REMOVE TOILET PARTITION AND ALL ASSOCIATED HARDWARE/FITTINGS. 10 REMOVE DOOR, FRAME, HARDWARE AND ALL ASSOCIATED FITTINGS/LIGHTS. 14 REMOVE BORROWED LIGHT, FRAME AND ALL ASSOCIATED FITTINGS. 20 REMOVE FLOORING TO SUBFLOOR OR FLOORING SUITABLE SURFACE FOR INSTALLATION OF NEW FLOOR (COORDINATE WITH FINISH PLAN). 30 REMOVE CEILING/SOFFITS AND ALL ASSOCIATED FRAMING/FIXTURES/DEVICES/EQUIPMENT (COORDINATE WITH MEP/FP/STRUCTURAL). 31 REMOVE CEILING/SOFFITS AND ALL ASSOCIATED FRAMING/FIXTURES/DEVICES/EQUIPMENT FOR CEILING SUPPORTED EXAM LIGHTS (COORDINATE WITH MEP/FP/STRUCTURAL). 41 REMOVE COUNTER, CABINETS, SHELVES AND ALL ASSOCIATED HARDWARE/FIXTURES/FITTINGS. 42 REMOVE WALL PROTECTION AND ALL ASSOCIATED HARDWARE. 50 REMOVE PLUMBING FIXTURE AND ALL ASSOCIATED FITTINGS (COORDINATE WITH PLUMBING DRAWINGS). 63 REMOVE LOCKERS OR CASEWORK WITH CONCRETE BASE AND REMOVE CONCRETE BASE AND ALL ASSOCIATED HARDWARE/FITTINGS. 64 REMOVE WALL MOUNTED EQUIPMENT AND ALL ASSOCAITED HARDWARE/FITTINGS. 71 REMOVE PORTION OF STOREFRONT/CURTAIN WALL ASSEMBLY AS INDICATED. 90 REMOVE AND SALVAGE DOME LIGHTS TO BE STORED AND REINSTALLED PER OWNER'S DIRECTION. 91 REMOVE AND REINSTALL SOILED LINEN CHUTE DOOR. GENERAL DEMOLITION NOTES Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 CRASH RAILCR-1 CG-1 ACCENT CRASH RAILCR-2 PRIVACY CURTAIN CORNER GUARDS BLUE ACCENT CORNER GUARD CG-2 RIGID SHEET WP-1 GRAB BAR BLUE ACCENT RIGID SHEET WP-2 TAN ACCENT CORNER GUARD CG-3 HARDWOOD CRASH RAIL CR-3 HYDRAULIC CEMENT UNDERLAYMENT CHASE AREA FIRE EXTINGUISHER / FIRE EXTINGUISHER CABINET FEC UNDERSIDE OF STRUCTURE JOINT SEALER AND BACKING PROVIDE CASING BEAD WHERE EXPOSED TO VIEW CEILING RUNNER DEFLECTION ALLOWANCE SOUND ATTENUATION INSULATION AT E1 AND E3 PARTITIONS ONLY SUSPENDED CEILING WHERE SCHEDULED METAL STUDS 5/8" GYPSUM BOARD SCHEDULED BASE FLOOR RUNNER JOINT SEALER AND BACKING EACH SIDE TOP OF SLAB ( 6 5/8")BASEPLANCEILINGHEADE E1 E2 E3 NO FIRE RESISTANCE RATING NO ACOUSTICAL RATING NO FIRE RESISTANCE RATING NO ACOUSTICAL RATING SINGLE SIDED (3 5/8" STUD) SINGLE SIDED (3 5/8" STUD) SINGLE SIDED (2 1/2" STUD) SINGLE SIDED (2 1/2" STUD) 4 1/4" NO FIRE RESISTANCE RATING NO ACOUSTICAL RATING NO FIRE RESISTANCE RATING NO ACOUSTICAL RATING A2.00 31 MULTIPLE LAYERS OF GYPSUM BOARD (WHERE INDICATED) MULTIPLE LAYERS OF JOINT SEALER AND BACKING WHERE MULTIPLE LAYERS OF GYPSUM BOARD ARE SHOWN FLOOR RUNNER 3/8" TYPICALJOINT SEALER AND BACKING -PROVIDE FIRE STOPPING AT FIRE RATED PARTITIONS - PROVIDE SMOKE STOPPING AT SMOKE PARTITIONS - PROVIDE ACOUSTICAL SEALANT AT ACOUSTICAL PARTITIONS GYPSUM BOARD SCHEDULED BASE 3/8"PARTITION AS SCHEDULEDADJACENT MATERIALS JOINT SEALER AND BACKING 5/8" GYPSUM BOARD WOOD BLOCKING VINYL ACRYLIC EXTRUSION CONTINUOUS VINYL RETAINER WASHER & ALLIGATOR NOTE: CRASH RAIL TO BE MOUNTED AT 2'-8"TO C.L. AFF UNDERSIDE OF STRUCTURE JOINT SEALER AND BACKING PROVIDE CASING BEAD WHERE EXPOSED TO VIEW DEFLECTION ALLOWANCE SUSPENDED CEILING WHERE SCHEDULED SCHEDULED BASE FLOOR RUNNER JOINT SEALER AND BACKING EACH SIDE TOP OF SLABBASEPLANCEILINGHEAD F NO FIRE RESISTANCE RATING NO ACOUSTICAL RATING 1 1/2" FURRED WALL 7/8" RIGID FURRING CHANNEL 1 1/2" 5/8" GYPSUM BOARD NO FIRE RESISTANCE RATING NO ACOUSTICAL RATING RIGID FURRING CHANNEL OR "Z" FURRING MEMBER RIGID FURRING CHANNEL OR "Z" FURRING MEMBER EXTEND GYPSUM BOARD TO UNDERSIDE OF STRUCTURE IF NO CEILING SCHEDULED A2.00 31 5" UNLESS OTHERWISE NOTED ACOUSTICAL INSULATION INFILL ABOVE RUNNER WHERE WALL RUNS PERPENDICULAR TO DIRECTION OF DECK AT B PARTITION JOINT SEALER AND BACKING EACH SIDE PROVIDE CASING BEAD WHERE EXPOSED TO VIEW CEILING RUNNER DEFLECTION ALLOWANCE SOUND ATTENUATION INSULATION SUSPENDED CEILING WHERE SCHEDULED METAL STUDS 5/8" GYPSUM BOARD- AT 1 HOUR PARTITION USE 5/8" TYPE X GYPSUM BOARD SCHEDULED BASE FLOOR RUNNER JOINT SEALER AND BACKING EACH SIDE TOP OF SLAB (7 1/4")BASEPLANCEILINGHEADB B1 B2 B3 NO FIRE RESISTANCE RATING STC = 51, TEST #: RAL-TL-90-166 1 HOUR FIRE - UL# U465 STC = 51, TEST #: RAL-TL-90-166 NO FIRE RESISTANCE RATING STC = 51, TEST #: RAL-TL-90-166 1 HOUR FIRE - UL# U465 STC = 51, TEST #: RAL-TL-90-166 4 7/8" (3 5/8" STUD) 4 7/8" (3 5/8" STUD) 7 1/4" (6" STUD) 7 1/4" (6" STUD) 4 7/8" UNDERSIDE OF STRUCTURE A2.00 31 UNDERSIDE OF STRUCTURE JOINT SEALER AND BACKING EACH SIDE PROVIDE CASING BEAD WHERE EXPOSED TO VIEW CEILING RUNNER DEFLECTION ALLOWANCE SOUND ATTENUATION INSULATION SUSPENDED CEILING WHERE SCHEDULED METAL STUDS 5/8" GYPSUM BOARD- L 1/16" LEAD THICKNESS (MIN. HEIGHT 7'-0") SCHEDULED BASE FLOOR RUNNER JOINT SEALER AND BACKING EACH SIDE TOP OF SLAB (7 1/4")BASEPLANCEILINGHEADL NO FIRE RESISTANCE RATING STC = 41 4 7/8" GWB W/ LEAD (3 5/8" STUD) 4 7/8" A2.00 31 UNDERSIDE OF STRUCTURE JOINT SEALER AND BACKING EACH SIDE PROVIDE CASING BEAD WHERE EXPOSED TO VIEW CEILING RUNNER DEFLECTION ALLOWANCE SOUND ATTENUATION INSULATION SUSPENDED CEILING WHERE SCHEDULED METAL STUDS 5/8" GYPSUM BOARD- AT 1 HOUR PARTITION USE 5/8" TYPE X GYPSUM BOARD SCHEDULED BASE FLOOR RUNNER JOINT SEALER AND BACKING EACH SIDE TOP OF SLABBASEPLANCEILINGHEAD A NO FIRE RESISTANCE RATING VIF STC = 41 LIMITING HEIGHT 15'-7" WIDTH VIF (EXISTING STUD) VIF TOP RUNNER METAL STUDS 5/8" GYPSUM BOARD SCHEDULED BASE FLOOR RUNNER TOP OF SLABBASEPLANHEAD Y NO FIRE RESISTANCE RATING NO ACOUSTIC RATING 4 7/8" (3 5/8" STUD) 4 7/8" CONTINUOUS WOOD BLOCKING 3/8" x 3/8" CONTINUOUS REVEAL EACH SIDE AND AT EXPOSED ENDS HEIGHT ABOVE FLOOR SEE FLOOR PLANS AND INTERIOR ELEVATIONS CASING BEAD A2.00 31 3'-0"1 1/2"5/8" GYPSUM BOARD WOOD BLOCKING HARDWOOD CRASH RAIL NOTE: CRASH RAIL TO BE MOUNTED AT 2'-4" TO C.L. AFF7 1/4"1 1/2" ACOUSTICAL INSULATION INFILL ABOVE RUNNER WHERE WALL RUNS PERPENDICULAR TO DIRECTION OF DECK AT B PARTITION JOINT SEALER AND BACKING EACH SIDE PROVIDE CASING BEAD WHERE EXPOSED TO VIEW CEILING RUNNER DEFLECTION ALLOWANCE SOUND ATTENUATION INSULATION (3" MINERAL WOOL BATT) SUSPENDED CEILING WHERE SCHEDULED EXISTING METAL STUDS 5/8" GYPSUM BOARD- AT 1 HOUR PARTITION USE 5/8" TYPE X GYPSUM BOARD SCHEDULED BASE EXISTING FLOOR RUNNER EXISTING JOINT SEALER AND BACKING EACH SIDE EXISTING TOP OF SLABBASEPLANCEILINGHEAD G MAINTAIN FIRE RESISTANCE RATING MAINTAIN ACOUSTICAL RATING 5/8" GYPSUM BOARD UNDERSIDE OF STRUCTURE A2.00 31 EXISTING UNDERSIDE OF STRUCTURE JOINT SEALER AND BACKING EACH SIDE PROVIDE CASING BEAD WHERE EXPOSED TO VIEW CEILING RUNNER DEFLECTION ALLOWANCE SOUND ATTENUATION INSULATION SUSPENDED CEILING WHERE SCHEDULED METAL STUDS 5/8" GYPSUM BOARD- AT 1 HOUR PARTITION USE 5/8" TYPE X GYPSUM BOARD SCHEDULED BASE FLOOR RUNNER JOINT SEALER AND BACKING EACH SIDE TOP OF SLABBASEPLANCEILINGHEAD M NO FIRE RESISTANCE RATING STC= 5 1/2" (3 5/8" STUD) 5 1/2" STEEL ANGLE EXTENDED BASE FLASHING SHEET METAL COUNTERFLASHING BASE FLASHING CANT PROTECTION BOARD ASSEMBLY EXISTING ROOF MEMBRANE COVER BOARD ATTACHMENT BOLTS BASE PLATE NEOPRENE PAD SET IN SEALANT 1'-0"1. ALL WORK SHALL BE PERFORMED PER APPLICABLE CODES, ORDINANCES AND PER REQUIREMENTS OF ALL APPLICABLE REGULATORY AGENCIES AND AUTHORITIES HAVING JURISDICTION. 2. ALTERATIONS/RENOVATIONS ON THIS AND OTHER FLOORS NOT SPECIFICALLY CALLED OUT AS RENOVATION AREAS ARE TO BE DONE AS NECESSARY TO COMPLETE WORK SHOWN ON THE CONTRACT DOCUMENTS. REFER TO ENGINEER CONSULTANT AND VENDOR DRAWINGS TO IDENTIFY THE SCOPE OF WORK IN AREAS IDENTIFIED OUTSIDE THE ARCHITECTURAL DOCUMENTS. THE G.C. SHALL BE RESPONSIBLE FOR THE REMOVAL AND RESTORATION OF ALL EXISTING FINISHES DISTURBED BY THE WORK. WHERE TEMPORARY M.E.P. CONNECTIONS ARE REQUIRED, ALL FINISHES SHALL BE RESTORED IMMEDIATELY TO MAINTAIN OPERATION OF THE FACILITY, EVEN IF THE WORK WILL REQUIRE TO BE REMOVED AGAIN DURING THIS PROJECT. 3. ALL OPENINGS, IN EXISTING FLOORS AND WALLS ABOVE AND BELOW THE CEILING PLENUM, BOTH EXISTING AND AS A RESULT OF DEMOLITION ACTIVITIES SHALL BE PATCHED TO COMPLETE AND FINISH EXISTING WALLS AND FLOORS CONSISTENT WITH NEW WORK. ALL PATCHES SHALL BE MADE WITH MATERIALS CONSISTENT WITH THE WALL IN WHICH THE PATCH WILL BE LOCATED. 4. THE G.C. SHALL COORDINATE AND SCHEDULE ALL WORK WITH THE CLIENT AND/OR CLIENTS AUTHORIZED REPRESENTATIVE/PROJECT MANAGER. WORK SCHEDULED IN OCCUPIED AREAS SHALL BE UNDERTAKEN IN A MANNER SO AS NOT TO DISTURB THE OPERATION OF THE FACILITY. 5. WHERE A NEW SERVICE PENETRATES AN EXISTING WALL WHICH EXTENDS TO THE UNDERSIDE OF THE STRUCTURE, THE G.C. WILL BE RESPONSIBLE FOR PATCHING AND FIRE SAFING THE WALL AND FOR PROVIDING THE REQUIRED FIRE RATING AND FINISH. 6. PROVIDE BLOCKING IN WALL THROUGHOUT AS INDICATED ON DRAWINGS FOR ALL WALL MOUNTED ITEMS, INCLUDING ITEMS FURNISHED BY OWNER. 7. ITEMS IDENTIFIED AS NOT IN CONTRACT (NIC) ARE TO BE PURCHASED AND INSTALLED BY THE OWNER. THE G.C. SHALL COORDINATE INSTALLATION OF ALL ITEMS NIC WITH THE OWNER. 8. PROVIDE ALL HEADERS, LINTELS AND SUPPORTS AS NECESSARY FOR ALL WALLS AND PARTS OF WALLS SHOWN TO BE REMOVED. ALL NEW MEMBERS SHALL BE IN CONFORMANCE WITH THE MASSACHUSETTS STATE BUILDING CODE, 8TH EDITION. THE GC IS RESPONSIBLE FOR IDENTIFYING ANY STRUCTURAL BEARING CONDITIONS THAT BECOME APPARENT DURING DEMOLITION. ANY FOUND STRUCTURAL CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO REMOVAL OF STRUCTURAL MEMBERS. 9. IT IS THE INTENT OF THIS DOCUMENT THAT ALL NEW WIRING, PIPING FIXTURES, FITTINGS AND DEVICES BE RECESSED INTO EXISTING WALLS. THE CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING, PATCHING, REPAIRING, ETC. AS REQUIRED TO RECESS ITEMS IDENTIFIED ABOVE. 10. WHERE WALL MOUNTED ITEMS HAVE BEEN REMOVED, PATCH AND REPAIR EXISTING WALL. 1. ALL WALL PARTITIONS TO BE TYPE "B" UNLESS OTHERWISE NOTED. 2. WHERE NEW WALL IS NOT DIMENSIONED LAYOUT TO ASSUME NEW WALL IS ALIGNED WITH ADJACENT WALL. 3. ALL PARTITIONS ARE TO EXTEND TO THE UNDERSIDE OF THE EXISTING DECK AND TO BE SEALED ON BOTH SIDES. 4. ALL PENETRATIONS IN SMOKE AND FIRE RATED PARTITIONS ABOVE CEILING TO BE FIRE STOPPED. 5. ALL PENETRATIONS IN NON-RATED PARTITIONS ABOVE CEILING TO BE SEALED. A2.00 31 3 3/4" (5 1/4") UNDERSIDE OF STRUCTURE JOINT SEALER AND BACKING EACH LAYER PROVIDE CASING BEAD WHERE EXPOSED TO VIEW CEILING RUNNER DEFLECTION ALLOWANCE UL 3/8" - 1/2" SUSPENDED CEILING WHERE SCHEDULED SCHEDULED BASE CAVITY SHAFT WALL RUNNER JOINT SEALER AND BACKING EACH LAYER TOP OF SLAB CAVITY SHAFT WALL RUNNER BASE PLAN CEILING HEAD SOUND ATTENUATION INSULATION AT H1 AND H3 CAVITY SHAFT WALL STUDS 5/8" TYPE X GYPSUM BOARD CORE BOARD H H1 H2 H3 2 HOUR FIRE - UL#U438 STC = 46 2 HOUR FIRE - UL# U438 STC = 49 2 HOUR FIRE - UL#U438 STC = 47 2 HOUR FIRE - UL# U438 STC = 50 SHAFT WALL (2 1/2" STUD) SHAFT WALL (2 1/2" STUD) SHAFT WALL (4" STUD) SHAFT WALL (4" STUD) SCHEDULED FLOORING 4' - 0" WALL PROTECTION WALL BASE SEALANT 4"RESILIENT WALL BASE WALL PROTECTION CAP Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION As indicated 8/15/2016 9:47:34 AMA2.00 185-01-00 8/15/16 FLOOR PLANS GENERAL NOTES, KEYS, LEGENDS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER ACCESSORY KEY SCALE: SECTION DETAIL 1 1/2" = 1'-0" 12 PARTITION TYPE E, E1, E2 & E3 SCALE: SECTION DETAIL 3" = 1'-0" 31 TYPICAL PARTITION AT BASE DETAIL SCALE: SECTION DETAIL 3" = 1'-0" 22 TYPICAL GYPSUM BOARD PARTITION / ADJACENT MATERIAL SCALE: SECTION DETAIL 3" = 1'-0" 24 CRASH RAIL SCALE: SECTION DETAIL 1 1/2" = 1'-0" 13 PARTITION TYPE F SCALE: PLAN DETAIL 3/4" = 1'-0" 23 DOOR FRAME LOCATION SCALE: SECTION DETAIL 1 1/2" = 1'-0" 11 PARTITION TYPE B, B1, B2, AND B3 SCALE: SECTION DETAIL 1 1/2" = 1'-0" 15 PARTITION TYPE L SCALE: SECTION DETAIL 1 1/2" = 1'-0" 10 PARTITION TYPE A SCALE: SECTION DETAIL 1 1/2" = 1'-0" 20 PARTITION TYPE Y SCALE: SECTION DETAIL 3" = 1'-0" 25 HARDWOOD CRASH RAIL SCALE: SECTION DETAIL 1 1/2" = 1'-0" 14 PARTITION TYPE G SCALE: SECTION DETAIL 1 1/2" = 1'-0" 21 PARTITION TYPE M SCALE: SECTION DETAIL 1 1/2" = 1'-0" 32 EQUIPMENT SUPPORT CURB DETAIL GENERAL NOTES PARTITION NOTES SCALE: SECTION DETAIL 1 1/2" = 1'-0" 33 PARTITION TYPE H, H1, H2, H3 SCALE: SECTION DETAIL 3" = 1'-0" 34 TYPICAL RESILIENT BASE TO WALL PROTECTION TRANSITION Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 FECFDVCMGZV 7 8 910 1112131415 16 17 18 A5.10 8A A5.10 11A A5.10 A5.10 2A A5.10 1A A5.12 27A A5.12 26A A5.12 29A A5.11 25A A5.1124B A5.105D A5.11 20A A5.11 16A A5.11 18A A5.10 4A A5.11 22A 8B 8C 8D 1B 1C 1D 2B 2C 2D 22B 22C 22D 4B 4C 4D 27B 27C 27D 26B 26C 26D 16B 16C 16D 29B 29C 29D 11B 11C 11D 20B 20C 20D A5.11 17A 17B 17C A5.10 13C 18B 18C 18D 19 20 21 22 23 25 26 27 28 5A 5B 5C 24C 24D 25B 25C 25D A5.1228D 28B 28C 13B13D A5.10 12A 12B 12C 12D A5.10 14A 14B 14C 14D A5.107D 7A 7B 7C A5.10 15A 15C A5.12 32C A5.12 31C A5.12 36A A5.12 35A A5.1234D A5.12 33C 31B 31A 31D 32A 32B32D A5.11 19A 19B 19C 19D 36B 36C 36D 33D 33A 34B 34C 35B 35C 35D A5.10 3B 13A 3A 3C 3D28A 34A 33B 9B 9C 9D 9A A5.1122H A5.10 SCOPE OF WORK RADIOLOGIST WORKROOM G-124 LARGE MAMMOGRAPHY G-120 CLEAN WORK AREA G-126A INTERVIEW 2 G-117 PATIENT CHANGING ROOM 3 G-111C ADJUSTABLE SHELVING PATIENT CHANGING ROOM 1 G-111D PATIENT CHANGING ROOM 2 G-111B STAFF TOILET G-130A EXAM 2 G-107 SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A BONE DENSITY G-113 GOWNED SUB-WAITING G-1107'-4 3/4"7'-6 1/2"5'-4"7'-8"7'-5 1/2" 12'-0" 10'-5 1/4"22'-1 3/4"14'-0 3/4"12'-2 1/2"6'-6"ALIGN6'-0"9'-2"2'-3"9'-7" ALIGNALIGN CG-1 CG-1 CG-1 CG-1 CG-1 CG-1 CG-1 CG-1 E1 E1 E1 E1 E1 E1 E1 E1 E1 G E1 E1 E1 E1 E1 E1 E1 E1 E1 F E1 E1 E1 E1 E1 E1 1 E1 E1 WP-1 WP-1 WP-1 WP-1 CG-1 CG-2 CG-2 WP-1 WP-2 WP-1 WP-1 WP-1 WP-1 WP-1 WP-2 WP-1 WP-1 WP-1 WP-1 CG-1 WP-1 CG-1 MAMMOGRAPHY G-122 WP-1 G G E1 E1 E1 E1 E1 ALIGN CG-1CG-1 CG-1 NURSE STATION G-126 CG-19'-5"11'-3 3/4"6'-4" 12'-1" 12'-11 3/4" CLEAR 3'-3" STAFF BREAK ROOM G-123 12'-3 1/2"6'-0"5'-7" E1 E1 E1 E1 E1 E1 E1 E1 H H E1 CG-1 CG-1 ULTRASOUND G-121 E1E1 WP-1 WP-1 WP-1 F E1 E1 E1 E1 STRETCHER WAITING G-127 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 OFFICE G-108 EXAM 1 G-106 STEREOTACTIC G-105 NAVIGATOR'S OFFICE G-116 INTERVIEW 1 G-118 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B SUB WAITING G-119 PATIENT TOILET G-109 G GALIGN G G G GG E1 E1 E1 E1 H H H E1 E1 G F F F F F F EQEQEQEQ5'-9"2'-9 1/4"6'-8 3/4" A5.10 5A . 5B .5C . 5D.A5.11 18A . 18B .18C . 18D.24A CG-1 WP-2 WP-1 WP-1 WP-1 WP-1 WP-2 WP-1 WP-1 WP-1 CG-1 2 CG-3 CG-3 CG-3 WP-1 WP-1 WP-2 WP-1 WP-1 WP-1 WP-1 4'-2"EQ EQ WP-2CLEAR5'-0"CLEAR5'-0"5'-3"WP-1 WP-1 WP-1 WP-1 WP-1 WP-1 WP-1 CG-1 7'-11 1/2" +/-EQEQ 19'-5"E1 4'-11" 7'-1" 1'-0" 5'-6"1'-6"E1 E1 FG 9'-11"5'-2 1/4" +/-5'-11"E1 LIAISON G-114C E1 A5.1010D E1 CG-1 A9.30 22 A9.40 31 G-114-AG-119A-AG-119B-B G-113A G-111A-A G-112-A G-111D-AG-111C-AG-111B-A5'-9 1/4" +/- CL G-110-B 7'-1" G-109-A E1 G-108-ACL CL EQ.G-106-AG-107-AFRAME TIGHT TO COLUMN G-105-A G-115B-A CL G E1 E1 G-116-AG-117-AG-118-AG-121-AG-122-AG-124-AG-123-A G-125-AG-127-AG-120-AG-126A-AG-130B-AG-130-AG-130A-AG-119-BG-119B-AG-119-AG-115A-B H H E1 E1E1 E1 E1 E1 G-110-A 1E 1G WP-1 E1 E1 E1 1'-9" ALIGN ALIGN WP-1 1'-3" WP-1 WP-1 E1 CG-2 WP-1 WP-2 WP-1 WP-1 WP-1 WP-1 WP-2 WP-1 CG-1 CG-1 CG-1 A9.20 32 CG-1 A9.60 10 L A9.20 34 FEATURE WALL FEATURE WALL 6'-8"CL CG-1 CG-1 CG-1 CG-1 WP-1WP-1 WP-2 WP-2 WP-1 CG-1 CG-1 CG-1 CG-1 CR-2 CR-2 CG-1 CR-3 CR-3 CR-3 CR-1CR-1CR-1 CR-2 CR-1 CR-1 CR-1 CR-1 CR-3 A5.1230C A5.11 23A A5.10 6B A5.1121D 30A 30B 30D 23D 23C 6C 6D 21A 21B A EQEQ CORRIDOR G-115C CORRIDOR G-115B CORRIDOR G-111 CORRIDOR G-115A CORRIDOR G-128 CORRIDOR G-119B A9.20 24 A9.20 24 ALIGNE2EQ F F F CR-1 CR-1CR-1 1' - 6" CLEAR 3' - 0"CLEAR4'-0"3'-5 1/2" +/- TECH WORKSTATION A9.6012.A9.60 11 . M M M G G G G G A5.10 10B .7'-11"7'-1" 6' - 6"9'-7"SUB WAITING PATIENT TOILET G-119A MEN'S CHANGING & WAITING G-114 CG-1 CG-1 Y Y 9'-0"A5.12 36F GG E2 E2 E2 7'-8"7'-3"13'-2" 7'-7"3'-5"13'-0"18'-4"7'-0"10'-6" 7'-4 1/2"7'-4 1/4"20'-9 3/4"17'-11 1/2"12'-3 3/4" 20'-7" 7'-5"5'-4"7'-4"10'-6"CR-2 CR-2 G PROVIDE 4'-0" HIGH, 3/4" FIRE RATED PLYWOOD WIDTH OF CLOSET 24" AFF. PAINTED FIELD COLOR, TYP.CLEAR3'-6"CLEAR 7'-3" FEC FEC H Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION 1/4" = 1'-0"8/15/2016 9:47:36 AMA2.10 185-01-00 8/15/16 NEW WORK PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 MGZV 7 8 910 1112131415 16 18 19 20 21 22 23 25 26 27 28 SCOPE OF WORK RADIOLOGIST WORKROOM G-124 LARGE MAMMOGRAPHY G-120 CLEAN WORK AREA G-126A INTERVIEW 2 G-117 PATIENT CHANGING ROOM 3 G-111C PATIENT CHANGING ROOM 1 G-111D PATIENT CHANGING ROOM 2 G-111B LIAISON G-114C STAFF TOILET G-130A EXAM 2 G-107 SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A BONE DENSITY G-113 GOWNED SUB-WAITING G-110 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B STAFF BREAK ROOM G-123 STRETCHER WAITING G-127 NURSE STATION G-126 MAMMOGRAPHY G-122 ULTRASOUND G-121 INTERVIEW 1 G-118 NAVIGATOR'S OFFICE G-116 STEREOTACTIC G-105 SUB WAITING G-119 PATIENT TOILET G-109 OFFICE G-108 EXAM 1 G-106 2'-5" 1'-11"3'-0"2'-6"3'-2"4'-3"5'-3"5'-7"5'-7" CL CL 4'-9"1'-5"1'-7"CL 1'-9" 6'-0" CL CL 2'-8" CL 3'-7"2'-3"4'-5"2'-6"2'-4"1'-11"CL CL 4'-6"1'-6"3'-6"1'-2"4'-5"1'-7"CL CL3'-3"1'-4"2'-4"CL CL 10" EQ EQ 1'-8" EQ EQ 2'-0"2'-11"CL EQEQCL 2'-0"2'-0"3'-5"2'-0"2'-0" CL CL CL CL CL CL CL CL CL CL CL6'-7"1'-3"5'-3"3'-5"3'-2"5'-11"5'-10"2'-1"2'-0"5'-11"5'-5"5'-2"4'-2"5'-8"7'-1"2'-5"CL 2'-9" CL 1'-6"4"EQEQEQ4'-9" 4'-3"4'-6" 1'-1"4'-3"4'-0"2'-0"CL CL SUB WAITING PATIENT TOILET G-119A MEN'S CHANGING & WAITING G-114 1'-7" 3'-0"1'-6"8'-2"3'-6"1'-9" LOCATED ABOVE CEILING LOCATED ABOVE CEILING 1'-7"4'-8"1'-6"1'-6"1'-6"1'-9"1'-9" CL 2'-11"3'-6 1/2"7"1'-2" CL CL 1'-0"1'-4"1'-0"CL 7'-0"8"CR PO CR PO PO CR PO NC NC NC NC NC NC NC NC NCNC NC NC NC NC NC NC NC NC 1' - 6"1' - 6"1'-7"1'-6"1' - 0"1' - 0"2'-10"1'-0" 1'-0"3' - 11"3' - 8"1' - 7"CL CL CL3' - 8"3' - 11"2' - 11"2'-6 3/4"10'-3"1'-1" 2'-7" 1'-0" 11"2'-5"1'-6"8"1'-6"EQEQEQEQ3'-4" 6"6"3'-3"1'-10"1'-0"3'-11"2'-1"2'-4"3'-6"3'-4"2'-1"3'-4"9'-4"5'-3"9"7'-4"3'-5" 3'-4"2'-7 1/4"CL 4'-3"5'-4"1'-8"1'-7"1'-4"6"1'-3"2'-9" 3" 1'-6" 1'-8"1'-6" 1'-10" 4'-1"2'-3"1'-0"1'-0"EQEQ CL 8"2'-3"1'-7"3'-0" EQEQ4'-10"5'-0"CL CL 5' - 0"NC NC 1'-3"5'-9"NC 1' - 0" NC 1' - 0" NC 1' - 2" ELECTRICAL CLOSET G-125 1'-0"1'-6"9'-5"10"1'-11"6'-10"2'-1"3'-2"7'-0" 1'-2" DUPLEX OUTLET DOUBLE DUPLEX OUTLET T/D OUTLET PO POWER OPERATOR WALL PHONEW NURSE CALLNC NOTE: REFER TO AND COORDINATE WITH DETAILS ON SHEET A5.00 FOR TYPICAL LIGHT SWITCH, THERMOSTAT, OULET, AND NURSE CALL LOCATIONS. LOCATIONS ARE TYPICAL UNLESS OTHERWISE NOTED. LIGHT SWITCH AUDIO VISUAL ALARMAVAF Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION 1/4" = 1'-0"8/15/2016 9:47:37 AMA2.11 185-01-00 8/15/16 NEW PLAN POWER COORDINATION COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER POWER COORDINATION NOTES Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 5 6 7 8 910 1112131415 16 17 18 19 20 21 22 23 24 25 26 27 28 ALTERNATE 1 32 A2.00 WEST BUILDING ROOF SCOPE OF WORK BELOW Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION 1/4" = 1'-0"8/15/2016 9:47:39 AMA2.12 185-01-00 8/15/16 ROOF PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER Issuance Schedule Number Date Description MGZV AP ACRYLIC PANEL CT CERAMIC TILE GT GLASS TILE PC PRIVACY CURTAIN PL PLASTIC LAMINATE PT PAINT RB RESILIENT BASE RSF RESILIENT SHEET FLOORING SS SOLID SURFACE TS TACKABLE SURFACE HW HARDWOOD SCOPE OF WORK RADIOLOGIST WORKROOM G-124 LARGE MAMMOGRAPHY G-120 CLEAN WORK AREA G-126A INTERVIEW 2 G-117 PATIENT CHANGING ROOM 3 G-111C PATIENT CHANGING ROOM 1 G-111D PATIENT CHANGING ROOM 2 G-111B LIAISON G-114C STAFF TOILET G-130A EXAM 2 G-107 SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A BONE DENSITY G-113 GOWNED SUB-WAITING G-110 PT-1 PT-2 PT-3 RSF-1 RB PL-1 SS PT-1 PT-2 PT-3 RSF-1 RB PL-1 SS PC SS PT-1 PT-2 RSF-1 RB PL-1 SS PC PL-1 PL-1 PC PC SS PT-1 PT-2 PT-3 RSF-1 RB PL-1 SS PT-1 PT-2 PT-3 RSF-1 RB PL-1 SS PT-1 PT-2 PT-3 RSF-1 RB SSPL-1 SS PT-1 PT-2 PT-3 RSF-1 RB PT-1 PT-2 RSF-1 RB PL-1 SS PL-1 SS PT-1 PT-2 RSF-1 RB PT-1 PT-2 PT-3 RSF-1 RB PT-1 PT-2 PT-3 RSF-1 RB PT-1 PT-2 PT-3 RSF-1 RB PT-1 PT-2 PT-3 RSF-1 RB PL-1 SS PT-1 PT-2 RSF-1 RB PL-1 SS PL-1 PT-1 PT-2 RSF-1 RB PT-1 PT-2 RSF-1 RB PT-1 PT-2 RSF-1 RB PT-1 PT-2 RSF-1 RB PT-1 PT-2 PT-2 RSF-1 RB PT-1 PT-2 RSF-1 RB PT-1 PT-2 RSF-1 RB PL-1 SS PT-3 PL-1 PL-1 PT-1 PT-2 RSF-1 RB PT-1 PT-2 RSF-1 RB PT-3 PT-1 PT-2 CT PT-1 PT-2 RSF-1 RB PT-1 PT-2 CT PT-1 PT-2 CT PT-1 PT-2 RSF-1 RB PT-1 PT-2 RSF-1 RB PT-1 PT-2 RSF-1 RB PL-1 HW PT-1 PT-2 RSF-1 RB PL-1 PT-1 PT-2 RSF-1 RB PL-1 PT-1 PT-2 CT RSF-2 SS PL-1 PL-1 STAFF BREAK ROOM G-123 MAMMOGRAPHY G-122 ULTRASOUND G-121 INTERVIEW 1 G-118 NAVIGATOR'S OFFICE G-116 STEREOTACTIC G-105 EXAM 1 G-106 OFFICE G-108 PATIENT TOILET G-109 SUB WAITING G-119 NURSE STATION G-126 STRETCHER WAITING G-127 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B RSF-2 SS RSF-2 RSF-2 SS PT-2 PT-3 SS PT-1 PT-2 RSF-1 RB PT-2 SS PT-1 PT-2 RSF-1 RB SS SS SS PT-3 PT-4 PT-4 PL-2 PL-2 PL-2 PL-2 HW PL-1 PL-2 PL-1 PL-2 PL-2 PL-2 PL-2 PL-1 PL-2PL-2 PL-2 PL-2 GT GT GT GT GT GT GT AP TS GT PL-1 PL-1 SUB WAITING PATIENT TOILET G-119A CORRIDOR G-119B MEN'S CHANGING & WAITING G-114 CORRIDOR G-111 CORRIDOR G-115A CORRIDOR G-115C CORRIDOR G-115DCORRIDOR G-128 ELECTRICAL CLOSET G-125 RSF-1 RB ACCENT WALL & SOFFIT RSF-1 RB PATCH EXISTING FLOORING MATCH EXISTING PATTERN LVT-1 LVT-2 HW HW HW HW HW 1. ALL WALLS AND SOFFITS TO BE PAINTED FIELD COLOR , UNLESS OTHERWISE NOTED. 2. ALL DOOR AND WINDOW FRAMES TO BE PAINTED TRIM COLOR. 3. PROVIDE MARBLE THRESHOLDS AT ALL TOILET LOCATIONS. 4. PROVIDE STAINLESS STEEL EDGE PROTECTOR TRIM WITH EASED EDGES AT TOP EDGE OF CERAMIC WALL TILE. 5. PROVIDE TRANSITION STRIPS AT ALL CHANGE IN FLOORING MATERIAL INTERSECTIONS. 6. WHERE CERAMIC TILE WALL BASE MEETS CERAMIC TILE FLOOR, USE SEALANT IN LIEU OF GROUT AT INTERSECTION. 7. WALL BASE TO BE STRAIGHT BASE AT CARPET, COVE BASE AT TILE. 8. SOFFITS AT ACCENT PAINT WALLS TO BE PAINTED ACCENT COLOR. 9. ALL FLOORING TO CONTINUE UNDER MILLWORK/CASEWORK UNLESS OTHERWISE NOTED. SCHEDULED RESILIENT SHEET FLOORING WALL TILE TILE TRIM TILE TRIM INTEGRAL BASE CAP 4"GRAIN DIRECTION ACCENT PAINT RESILIENT SHEET FLOORING SEAM LVT-2 LVT-1 Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION As indicated 8/15/2016 9:47:40 AMA4.00 185-01-00 8/15/16 FINISH PLAN GENERAL NOTES, KEYS, LEGENDS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER ABBREVIATIONS - FINISHES FINISH SCHEDULE FINISH MANUFACTURER STYLE/NUMBER COLOR NOTES AP 3-FORM CHROMA DENIM B31 + WHITE OUT W01 CT AMERICAN OLEAN INFUSION PORCELAIN TAUPE WENGE TOILET ROOM WET WALL, GROUT TO BE LATTE 40 GT CROSSVILLE EBB & FLOW SAND AND SURFACE BACKSPLASH, GROUT TO BE SAUTERNE 18 HW LIGHT MAPLE SCHEDULED CRASH RAIL, LIASON DESK, CHANGING ROOM BENCHES AND WAITING ROOM DETAILS LVT-1 ARMSTRONG ARBOR ART EXOTIC CHERRY CHESTNUT EXISTING FLOORING LVT-2 ARMSRONG EARTH CUTS HAVEN STONE GRAY PEARL EXISTING FLOORING PC ARCHITEX INTERNATIONAL RX 6008 PULA PRIVACY CURTAIN PL-1 WILSONART 4942-38 CRISP LINEN MILLWORK PL-2 WILSONART 4944-38 CASUAL LINEN MILLWORK BASE CABINETS PT-1 BENJAMIN MOORE WOOD ASH 1065 FIELD PAINT PT-2 BENJAMIN MOORE BLOND WOOD 1067 TRIM PAINT & ACCENT PAINT PT-3 BENJAMIN MOORE NORTHERN AIR 1676 BLUE ACCENT PAINT PT-4 BENJAMIN MOORE MINERAL PROFILE PANELING FEATURE WALL WHITE PAINT RB JOHNSONITE 49 BEIGE FIELD FLOORING BASE RSF-1 FORBO MARMOLEUM STRIATO WHITE WASH 5230 NET FIT SEAMS WITH RUBBER BASE, FIELD FLOORING RSF-2 FORBO MARMOLEUM STRIATO WHITE WASH 5230 HEAT WELDED SEAMS WITH INTEGRAL BASE, TOILET ROOMS SS CORIAN BISQUE MILLWORK TS FORBO BULLETIN BOARD 2185 - BLUE TACKABLE SURFACE SCALE: 1/4" = 1'-0"1 FINISH PLAN FINISH NOTES SCALE: SECTION DETAIL 3" = 1'-0" 10 RESILIENT SHEET FLOORING TO WALL TILE TRANSITION FINISH FLOOR PATTERN KEY Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 MGZV 7 8 910 1112131415 16 18 19 20 21 22 23 25 26 27 28 SCOPE OF WORK RADIOLOGIST WORKROOM G-124 LARGE MAMMOGRAPHY G-120 CLEAN WORK AREA G-126A INTERVIEW 2 G-117 PATIENT CHANGING ROOM 3 G-111C PATIENT CHANGING ROOM 1 G-111D PATIENT CHANGING ROOM 2 G-111B LIAISON G-114C STAFF TOILET G-130A EXAM 2 G-107 SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A BONE DENSITY G-113 GOWNED SUB-WAITING G-110 STAFF BREAK ROOM G-123 MAMMOGRAPHY G-122 ULTRASOUND G-121 INTERVIEW 1 G-118 NAVIGATOR'S OFFICE G-116 STEREOTACTIC G-105 EXAM 1 G-106 OFFICE G-108 PATIENT TOILET G-109 SUB WAITING G-119 NURSE STATION G-126 STRETCHER WAITING G-127 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B GRAIN DIRECTION 6'-7"GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION 6'-7"6'-7"GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTIONGRAIN DIRECTION6'-7"6'-7"6'-7"6'-7"6'-7"6'-7"6'-7"GRAIN DIRECTION GRAIN DIRECTION ELECTRICAL CLOSET G-125 CORRIDOR G-115ACORRIDOR G-128 CORRIDOR G-115D CORRIDOR G-115C CORRIDOR G-115B MEN'S CHANGING & WAITING G-114 SUB WAITING PATIENT TOILET G-119A CORRIDOR G-119B STARTING POINT FOR SEAMING CORRIDOR G-115B6'-7"6'-7"PATCH EXISTING FLOORING Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION 1/4" = 1'-0"8/15/2016 9:47:41 AMA4.10 185-01-00 8/15/16 SEAMING DIAGRAM COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER Issuance Schedule Number Date Description STANDARD CASEWORK TAG NUMBER DESIGNATIONS REFER TO ARCHITECTURAL WOODWORK STANDARDS (EDITION 1), CABINET DESIGN SERIES, APPENDIX A, PAGE 351 AND FOLLOWING. ("AWS CDS") BASE CABINETS WITH COUNTERTOP: HEIGHT IS NOMINAL TO TOP OF COUNTERTOP WALL AND TALL CABINETS HEIGHT IS ACTUAL H H 999= CASEWORK TAG NUMBER OR LETTER DESIGNATION FOUND IN "AWS CDS" M= INDICATES A MODIFICATION TO "AWS CDS" CASEWORK AS DESCRIBED IN COMMENTS, NOTES OR DETAILS W= WIDTH H=HEIGHT (SEE NOTES) D=DEPTH (INCHES) 999M W H D COMMENT/ MODIFICATION D D W W CASEWORK TAG DESIGNATIONS MAY ALSO REFER TO ISGENUITY COMPONENTS AND CUSTOM CASEWORK ELEMENTS FOR CABINET TYPES THAT "AWS CDS" DOES NOT COVER. THESE TAGS WILL CONTAIN LETTERS. REFER TO CASEWORK MENU ON THIS PAGE FOR MORE INFORMATION ON THESE CUSTOM CABINETS. "AWS CDS" NOTES: THE CASEWORK DESIGN SYSTEM IS SUBDIVIDED AS FOLLOWS: 100 SERIES BASE CABINETS W/O DRAWERS 200 SERIES BASE CABINETS WITH DRAWERS 300 SERIES WALL-HUNG CABINETS 400 SERIES TALL STORAGE CABINETS 500 SERIES TALL WARDROBE CABINETS 600 SERIES LIBRARY CABINETS 700 SERIES MOVEABLE CABINETS FOR ISGENUITY CUSTOM CABINETS, FIRST DIGIT OF TAG WILL FOLLOW THESE CATEGORIES. 9C9 W H D 9C9= CASEWORK TAG DESIGNATION FOR CUSTOM CASEWORK NOT FOUND IN "AWS CDS" W= WIDTH H=HEIGHT (SEE NOTES) D=DEPTH (INCHES) AS W D CT W H D REFER TO AWS CDS LEGEND GENERAL NOTES AS WELL AS STANDARDS PROMULGATED IN THE ENTIRE BOOK FOR DETAILS OF CONSTRUCTION. WALL AND TALL CABINETS HEIGHT IS ACTUAL H D W 999M W H D WITH FASCIA THE FOLLOWING NOTES SHALL BE THE DEFAULT, EXCEPT AS NOTED OTHERWISE ON THE DRAWINGS. 1. PROVIDE LOCKS AT ALL DRAWERS AND CABINETS AS INDICATED ON THE ELEVATIONS 2. COUNTERTOPS AT ALL OUTSIDE CORNERS SHALL HAVE A 2” RADIUS CORNER IN PLAN VIEW. 3. AT TOPS AND EXPOSED SIDES OF ALL WOOD WALL, TALL, AND FULL HEIGHT CABINETS PROVIDE A CONTINUOUS FASCIA PANEL ABOVE BANK OF CABINETS, FINISHED TO MATCH FACING OF ADJACENT CABINETS. WHERE ACT CEILING IS ABOVE, CEILING TILES SHALL BE SCRIBED AROUND THE FASCIA PANEL WHICH SHALL EXTEND AT LEAST 2” ABOVE THE CEILING . WHERE GWB SOFFIT IS ABOVE, FASCIA PANEL SHALL BE 2” HIGH AND SCRIBED TO SOFFIT. GC TO COORDINATE SIZE AND LOCATION OF GWB SOFFIT WITH FINAL CASEWORK SHOP DRAWINGS. 4. PROVIDE WIRE PULLS ON DRAWERS AND CABINETS TYPICALLY. OMIT THEM AT FIXED PANEL FRONTS. WHERE SINK CABINETS HAVE A FIXED PANEL FRONT IN LIEU OF SWINGING DOORS, PROVIDE SCREWS AT EACH CORNER OF PANEL. 5. ATTACH BACKER BOARD SCREWS WITH 1” DIAMETER STAINLESS STEEL ESCUTCHEONS. 6. UNDERNEATH WALL CABINETS, PROVIDE APRONS AT FRONT, AND POPLAR BLOCKING AT WALL. 7. PROVIDE GROMMETS AND COORDINATE LOCATIONS IN THE FIELD WITH OWNER. 8. ALIGN DRAWER / CABINET HEIGHTS ACROSS A TYPICAL ELEVATION WHETHER OR NOT COORDINATED AS SUCH ON THE INTERIOR ELEVATION. LOCATE LOCKS IN A CONSISTENT AND ALIGNED MANNER ON CABINETS AND DRAWERS. 9. TYPICAL DIMENSIONS: COUNTERTOPS 1-1/2” THICK, TOE KICK HEIGHT 4”, TOE KICK DEPTH 3”. 10. COUNTERTOP SUPPORT BRACKETS SHALL BE PROVIDED AT MINIMUM EVERY 36" OF UNSUPPORTED SPAN. ALL SUPPORT BRACKETS TO BE SURFACE MOUNTED UNLESS OTHERWISE NOTED. 11. PROVIDE WALL BASE AT TOE KICK LOCATIONS AT EXPOSED SIDES AND FRONTS OF CASEWORK. 12. PROVIDE ADJUSTABLE FEET AT BASE OF ALL BASE AND TALL CABINETS. 13. PROVIDE 3/4 INCH THICK PLYWOOD SCRIBE BEHIND WALL BASE AT TOE KICK. 14. PROVIDE WOOD BLOCKING IN WALLS BEHIND ALL CASEWORK. 15. PRIOR TO INSTALLATION, GC TO ENSURE THAT FLOOR LEVEL TOLERANCE IN A GIVEN DESK OR RUN OF CASEWORK SHALL NOT EXCEED 1/32 INCH IN 8 FEET. 16. HOLES FOR ADJUSTABLE SHELF CLIPS INSIDE CABINETS SHALL BE 1/4 INCH IN DIAMETER AND 2” OC INTERVALS. 17. PROVIDE SECURITY PANEL ABOVE FILE DRAWERS. 18. ADJUSTABLE SHELVES SHALL HAVE LOCATOR CLIPS ATTACHED TO UNDERSIDE OF SHELVES. 19. SHELVING STANDARDS SHALL BE PROVIDED, TO BE SPACED ALONG SHELF SPAN AT INTERVALS OF 36" OR LESS. PROVIDE 48> LONG SHELVING STANDARDS AND CUT TO SUIT LOCATIONS. STANDARDS NEAR ENDS OF THE SHELF SHALL BE LOCATED 6" AWAY FROM END OF SHELF, AND BE SPACED EQUALLY AT INTERIM LOCATIONS. 20. PROVIDE BOOKENDS AT ALL SIDES OF ALL ADJUSTABLE SHELVES EXCEPT AT LOCATIONS WHERE END SHELF IS WITHIN 1" OF AN ADJACENT WALL OR CASEWORK SURFACE. 21. PROVIDE BACKSPLASHES AND SIDESPLASHES TO MATCH COUNTERTOP SURFACE. PROVIDE INTEGRAL BACKSPLASHES AT SOLID SURFACE COUNTERTOPS. TYP. VOICE / DATA OUTLETS FIRE EXTINGUISHER/ FIRE EXTINGUISHER CABINET AREA ALARM PANEL / ZONE VALVE BOX CL AREA ALARM PANEL ZONE VALVE BOX 3' - 6"CL CL 2' - 6"4"3' - 0"4"3' - 6"4"1' - 6"3' - 2"COUNTER - DESK (WITH BACKSPLASH)3' - 8"COUNTER - STANDING (WITH BACKSPLASH)4' - 2"CL CL CL CL COUNTER - STANDING (HIGH) (WITH BACKSPLASH)5' - 0"4' - 0"1' - 6"ELECTRICAL OUTLET ELECTRICAL OUTLET ELECTRICAL OUTLET SCHEDULED WALL BASESEE ELEVATIONCG / CGE 2" BUMPER RAIL / CHAIR RAIL (VARIOUS TYPES, REFER TO INT. ELEVATIONS AND DETAILS FOR MOUNTING HEIGHT) WALL PROTECTION - CORNER GUARDS 5' - 6"CL HOOK STRIP 6' - 8"CL CLOCK 2' - 0"CL TOILET TISSUE DISPENSER MAX. 1' - 0" MIN. 3' - 6" 3' - 0" GRAB BAR 4' - 0"PULL-CORD STATION ACCESSIBLE TOILET AND ACCESSORIES CL 1' - 6"ACCESSIBLE LAVATORY MIRROR CL DIAPER CHANGING STATION2' - 10"CL NURSE CALL DUTY STATION 7' - 2"3' - 6"CL COMBINATION TOWEL DISPENSER / WASTE RECEPTACLE 3' - 6"SEAT COVER DISPENSER DOOR OPERATOR PUSH PAD CL 4' - 0"ACCESSIBLE GRAB BAR (BEHIND TOILET) CL 1' - 6" 3' - 6" GRAB BAR CL 3' - 0"CL CL ROBE HOOK5' - 6"ADA ROBE HOOK CL 4' - 0"4' - 0"VARIES VARIOUS LENGTHS 4' - 0"WALL PROTECTION - DOORS 6" LIGHT FIXTURE 7' - 0"CL 4' - 8"THERMOSTAT WALL PHONE LIGHT SWITCH PLATE7' - 8"NURSE CALL LIGHT AUDIO / VISUAL ALARM 6' - 8"4' - 0"FIRE ALARM PULL STATION CLFAPSCL 4' - 0"LS TYP. LIGHT SWITCH CL 4' - 0"SLC TYP. LIGHTING CONTROL SENSOR 4' - 6"TELEPHONE OUTLET THERMOSTAT5' - 0"TO TST DSCS NURSE CALL STATION SB NURSE CALL STATUS BUTTON 4' - 0"4' - 0"CLCL AP 4' - 0"ANNUNCIATION PANEL EXIT SIGN SUO PULL CORD STATION4' - 0"CL 1' - 6"TYP. ELECTRICAL OUTLETS CL 1' - 6"1' - 6"CL CARD ACCESS CL 4' - 0"OF TP ROLL 3' - 0"CL TOWEL DISPENSER CL 3' - 6"1' - 0"4' - 6"CL GENERAL NOTE: HEIGHTS INDICATED ARE FOR GENERAL CONDITIONS, UNLESS OTHERWISE NOTED. REFER TO INTERIOR ELEVATIONS FOR SPECIFIC MOUNTING HEIGHTS.2' - 8" C.L.4'-4" MINSHARPS CONTAINER4'-6" MAX2' - 10"3' - 4"6"6'-8" MIN8"NURSE CALL CL HAND SANITIZER 8" MIRROR1'-3"L1 KEYING GROUP LOCK REQUIRED BLOCKING, TYP. 3/4" PLYWOOD WITH PLAM 2' - 6"2'-3"3/4" PLYWOOD WITH PLAM DOOR 3/4" PLYWOOD WITH PLAM CLEAR 1'-2"2"UNDERCOUNTER LIGHT 2" Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION As indicated 8/15/2016 9:47:42 AMA5.00 185-01-00 8/15/16 INTERIOR ELEVATIONS GENERAL NOTES, KEYS, LEGENDS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER CASEWORK KEY GENERAL CASEWORK NOTES TYPICAL MOUNTING HEIGHTS MILLWORK KEYING SCHEDULE ROOM NUMBER ROOM NAME MILLWORK KEYING GROUP G-105 STEREOTACTIC GROUP 1 G-106 EXAM 1 GROUP 1 G-107 EXAM 2 GROUP 1 G-113 BONE DENSITY GROUP 1 G-120 LARGE MAMMOGRAPHY GROUP 1 G-121 ULTRASOUND GROUP 1 G-122 MAMMOGRAPHY GROUP 1 G-126 NURSE STATION GROUP 2 G-126A CLEAN WORK AREA GROUP 2 G-127 STRETCHER WAITING GROUP 2 G-110 GOWNED SUB-WAITING GROUP 3 G-111 CORRIDOR GROUP 3 G-123 STAFF BREAK ROOM GROUP 4 G-130B MANAGER'S OFFICE GROUP 5 G-124 RADIOLOGIST WORKROOM GROUP 6 MILLWORK KEYING LEGEND SCALE: SECTION DETAIL 1 1/2" = 1'-0" 20 UNDERCOUNTER LIGHT Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 STANDING WATER COOLER CL 6" PLUMBING CONNECTION OPEN TO BEYOND 1' - 6" CL CL 1'-0" 25 A2.00 TYP A9.50 11 MINERAL PROFILE PANELING FEATURE WALL LINE OF SOFFIT A9.40 30 CL 6" TOILET PAPER FULL HEIGHT TILE START WITH FULL TILE AT CORNER WALL SCONCE, TYP. PAPER SOAP PURELL OPEN TO BEYOND 6" 12 A9.20 CT 48 36 25 14 A9.20 PURELL CT 30 14 A9.20 CL EQEQ CHANGING ROOM BENCH PURELL CL 1'-8" PURELL CHANGING ROOM BENCH CL1'-1" PURELL 2'-0"CL PURELL PAPER SOAP TOILET PAPER WALL SCONCE, TYP.FULL HEIGHT TILE START WITH FULL TILE AT WALL 10 A4.00 PURELL CL1'-2" PURELL SOILED LINEN BIN TRAY RACK PAPER SOAP WALL PROTECTION, TYP. EQ EQCL OPEN TO BEYOND 3'-0"CL OPEN TO BEYOND 1'-1" CL PURELL PHONE CL 2'-2"4'-0"BONE DENSITY MACHINE EMERGENCY POWER AS 36 36 12 BONE DENSITY WORKSTATION EMERGENCY POWER SOAPPAPER WALL PROTECTION, TYP. CT 121 36 25 302 WITH FASCIA 30 17 14 302 WITH FASCIA 30 30 14 3 SHELVES 302 WITH FASCIA 30 30 14 3 SHELVES 302M 30 30 14 212 30 24 36 212 30 24 36 254 15 24 36 PANEL FRONT 151M 31 24 36 101M 15 24 36 21 A9.20 22 A9.20 11 A9.20 A9.20 31 L1 L1 PURELL 301 20 26 14 301 20 26 14 301 20 26 14 CT 63 40 25 16120 24 40 101 20 24 40 10120 24 40 SOILED LINEN HAMPER 11 A9.20 OPEN TO BEYOND CLEQ EQ L3 L3 L3 L3 L3 PLASTIC LAMINATE LOCKERS CL 3' - 0"CLEQ EQ X-RAY IN USE LIGHT EQ EQCL 24 A2.00 TYP EQEQCL COAT HOOKS ON HARDWOOD PANEL 4'-0"A9.40 10 EQ EQCL Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION 1/4" = 1'-0"8/15/2016 9:47:50 AMA5.10 185-01-00 8/15/16 INTERIOR ELEVATIONS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER 1/4" = 1'-0"1A SUB WAITING 1B 1C 1D 1/4" = 1'-0"2A PATIENT TOILET WAITING 2B 2C 2D 1/4" = 1'-0"3A LIAISON 3B 3C 3D4D4C4B 1/4" = 1'-0"4A NAVIGATOR'S OFFICE 7D7C7B 1/4" = 1'-0"7A MEN'S CHANGING & WAITING 11D11B11C 1/4" = 1'-0"11A CHANGING ROOM 112D12C12B 1/4" = 1'-0"12A CHANGING ROOM 213D13C13B 1/4" = 1'-0"13A CHANGING ROOM 3 14D14C14B 1/4" = 1'-0"14A PATIENT TOILET - CHANGING 9D9C9B 1/4" = 1'-0"9A SOILED HOLDING ROOM 15C 1/4" = 1'-0"15A CORRIDOR 8D8C8B 1/4" = 1'-0"8A BONE DENSITY GC TO PROVIDE BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, INCLUDING OFOI 1/4" = 1'-0"5A INTERVIEW 5B 5C 5D 10D 1/4" = 1'-0"10B PATIENT LOCKERS 1/4" = 1'-0"6B CORRIDOR G-115B 6C 6D 1E 1G Issuance Schedule Number Date Description STEREOTACTIC MACHINE EMERGENCY POWER STEREOTACTIC GENERATOR EMERGENCY POWER SURFACE MOUNTED RACEWAY1'-0"CIRCUIT BREAKER 2'-9" CL SHARPS BLACK BOX RED BOX 302 WITH FASCIA 30 26 14 3 SHELVES 101M 15 24 40 WALL PROTECTION TO UNDERSIDE OF COUNTER CORNER GUARDS TO UNDERSIDE OF COUNTER L1 GLOVES 3'-4"CL SOAPPAPER 302M 39 26 14 SUCTION DEVICE PANEL FRONT 151M 30 24 40 CT 40 12 A9.20 A9.20 31 WALL PROTECTION TO UNDERSIDE OF COUNTER 422 37 84 25 422 37 84 25 212 30 24 36 211 15 24 36 101M 15 24 36 PANEL FRONT 151M 31 24 36 302 WITH FASCIA 30 30 14 3 SHELVES 302 WITH FASCIA 30 30 14 3 SHELVES 11 A9.20 22 A9.20 302M30 30 14 A9.20 31 PAPER SOAP L1 L1 L1 L1 L1 L1 CT 91 36 25 SOAPPAPER 422 36 84 25 302 WITH FASCIA 30 30 14 3 SHELVES 302 WITH FASCIA 30 30 14 3 SHELVES 101M 15 24 36 211 15 24 36 212 30 24 36 PANEL FRONT 151M 31 24 36 22 A9.20 302M 30 30 14 11 A9.20 A9.20 31 L1 L1 L1 SHARPS WALL PROTECTION, TYP. CT 92 36 25 PHONE 1'-5" CL VERTICAL SURFACE WIREWAY, TYP. CIRCUIT BREAKER WALL MOUNTED PADDLES 3'-0"1'-0"1'-10"CL 2" DIA. GROMMETED CUTOUT, TYP. HORIZONTAL SURFACE WIREWAY, TYP 12 A9.20 PURELL CT 60 36 25 STEREO MONITOR STAND 12 A9.203'-8"1'-10"CL 11"WALL PROTECTION, TYP. SHARPS PROVIDE BLOCKING IN WALL 3'-0"4'-0" CL 2'-6"6'-0" PURELL PHONE SHARPS 1'-5" CL SOAP PAPER 302M 30 30 14 301 WITH FASCIA 15 30 14 301 WITH FASCIA 15 30 14 101M 15 24 36 PANEL FRONT 151M 30 24 36 211 15 24 36 254 24 24 36 421 24 54 25 22 A9.20 35 A9.20 11 A9.20 A9.20 31 STABLERISE14 A9.20 PURELL 6" CL CT 30 WALL PROTECTION, TYP. SHARPS PURELL PHONE 3'-0"CL SOAP PAPER 302 WITH FASCIA 30 30 14 302 WITH FASCIA 30 30 14 302 WITH FASCIA 30 30 14 212 30 24 36 212 30 24 36 254 15 24 36 101M 15 24 36 PANEL FRONT 151M 31 24 36 CT 122 36 25 22 A9.20 22 A9.20 A9.20 31 302M30 30 14 L1 L1 L1 L1 L1 L1 PAPER SOAP WALL SCONCE, TYP. TOILET PAPER FULL HEIGHT TILE START WITH FULL TILE AT WALL PURELL 1'-2" CL MED GAS ZONE VALVE BOX (ALTERNATE) EQ EQ CLEQEQ LINE OF SOFFIT BEHINDEQEQEQEQCLCLCLX-RAY IN USE LIGHT OPEN TO BEYONDOPEN TO BEYOND EXISTING LAUNDRY CHUTE 24 A2.00 TYP EQ EQ EQ EQ CLCLX-RAY IN USE LIGHT OPEN TO BEYOND OPEN TO BEYOND OPEN TO BEYOND EQ EQ CL 24 A2.00 TYP OPEN TO BEYOND EQ EQCL EQ EQCLX-RAY IN USE LIGHT OPEN TO BEYOND A9.50 12 6" CL 101M 15 24 36 101 24 24 36 101 24 24 36 WATER CT 65 36 25 11 A9.20 22 A9.20 MINERAL PROFILE PANELING FEATURE WALL LINE OF SOFFIT A9.40 12 L3 L3 OPEN TO BEYOND 18'-11" 25 A2.00 TYP EQ EQ EQ EQ CL CL OPEN TO BEYOND OPEN TO BEYOND EQ EQ Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION 1/4" = 1'-0"8/15/2016 9:47:56 AMA5.11 185-01-00 8/15/16 INTERIOR ELEVATIONS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER 22D22C22B 1/4" = 1'-0"22A STEROTACTIC 1/4" = 1'-0"25A MAMMOGRAPHY 25B 25C 25D 22H GC TO PROVIDE BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, INCLUDING OFOI 18D18C18B 1/4" = 1'-0"18A EXAM ROOM19D19C19B 1/4" = 1'-0"19A OFFICE 24D24C24B 1/4" = 1'-0"24A ULTRASOUND 1/4" = 1'-0"20A PATIENT TOILET 20B 20C 20D 1/4" = 1'-0"23A CORRIDOR G115 A A 23C 23D 21B 21D 1/4" = 1'-0"21A CORRIDOR G 115B 1/4" = 1'-0"16A GOWNED SUB-WAITING 16B 16C 16D 1/4" = 1'-0"17A CORRIDOR 17C17B Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 400 36 84 19 422 36 84 19 422 36 84 19 L5 L5 PRINTER, SM AS 36 36 12 AS 36 36 12 COAT HOOKS RECYCLEWASTEBASKET EQ EQ CL TOILET PAPER PAPER SOAP WALL SCONCE, TYP. FULL HEIGHT TILE START WITH FULL TILE AT WALL PURELL 1'-1" CL MOBILE PED MOBILE PEDMOBILE PEDPRINTER 100M TWO SHELVES 24.5 22 36 CT 25.6 36 25 COPIER 187M 24 22 28 CT 25.6 28 23 OPEN TO BEYOND VIEW BOX MOBILE PED MOBILE PED MOBILE PED EQ EQ CL 5' - 6"FILM COPIER 9"CL OPEN TO BEYOND EQ EQCL PURELL PHONE COAT HOOKS 4'-2"CL PLASTIC LAMINATE LOCKERS LOCKER FILLER PANELS EQ EQ PURELL 3'-0"CL CONFIDENTIAL RECYCLE CL 3'-8" COAT HOOKS PRINTER SOAP PAPER PANEL FRONT 151M 31 24 36 101M 15 24 36 302 WITH FASCIA 30 17 14 300 WITH FASCIA 30 30 14 300 WITH FASCIA 30 30 14 300 WITH FASCIA 30 30 14 CT 47 36 25 CT 104 30 25 302 28 30 14 11 A9.20 22 A9.20 14 A9.20 L6 WALL SCONCES, TYP 3'-0"CL 10" REFRIGERATOR PAPER SOAP MIRCROWAVE KEURIG 301 15 28 14 302 30 28 14 326M MICROWAVE SHELF 20"D 30 28 14 302 WITH FASCIA 30 17 14 PANEL FRONT 151M 31 24 36 CT 106 36 25 101M 15 24 36 11 A9.20 22 A9.20 254 20 24 36 254 20 24 36 254 20 24 36 WATER L4 L4 L4L4 L4 L4 L4 PHONE PURELL 1'-6"CL SHARPS PHONE PURELL SOAP PAPER WALL PROTECTION, TYP. CODE CART 302 WITH FASCIA 30 17 14 302 WITH FASCIA 30 30 14 301 21 30 14 PANEL FRONT 151M 30 24 36 DEFIBRILLATOR CT 36 22 A9.20 11 A9.20 101M 15 24 36 212 25 24 36 L2 L2 L2 SHARPS 302 36 17 14 ICE UC FRIDGE WATER LINE AND DRAIN L2 STRETCHER STRETCHER A9.40 11 A9.40 11 . CL CL EQEQ EQEQ 3'-9"7'-7" MEDICAL GASES ALTERNATE 4'-0"WALL PROTECTION, TYP. 301 WITH FASCIA 12 30 14 3 SHELVES 302 WITH FASCIA 30 30 14 3 SHELVES 302 WITH FASCIA 30 30 14 3 SHELVES 302 WITH FASCIA 30 30 14 3 SHELVES 25415 24 36 212 30 24 36 212 30 24 36 211 17 24 36 21 A9.20 11 A9.20 L1L1 L1L1 PAPERSOAP 301 WITH FASCIA 15 30 14 3 SHELVES 302M 30 30 14 301 WITH FASCIA 15 30 14 3 SHELVES 302 WITH FASCIA 31 30 14 3 SHELVES 212 36 24 36 PANEL FRONT 151M 30 24 36 101M 15 24 36 422 31 84 24 422 31 84 24 22 A9.20 CT 36 A9.20 31 L1 L1 WALL MOUNTED PADDLES 3' - 0"1'-10"2" DIA. GROMMETED CUTOUT, TYP. HORIZONTAL SURFACE WIREWAY, TYP1'-0"PURELL PHONE CT 36 36 18 2'-0" CL VERTICAL SURFACE WIREWAY, TYP. CIRCUIT BREAKER 12 A9.20 CT 95 30 25 3'-2"10" CL1'-6" PAPER SOAP PANEL FRONT 151M31 24 36 212 37 24 36 302 WITH FASCIA 37 30 14 302 WITH FASCIA 30 30 14 302 WITH FASCIA 30 17 14 CT 100 36 25 211 15 24 36 101M 15 24 36 22 A9.20 11 A9.20 L2 L2 L2 L2 L2OPEN TO BEYOND PURELL PHONE PURELL METRO RACKMETRO RACK WALL PROTECTION, TYP. PAPERSOAP 212 30 24 36 211 15 24 36 302 WITH FASCIA 30 17 14 302 WITH FASCIA 30 30 14 302 WITH FASCIA 30 30 14 CT 110 36 25 PANEL FRONT 151M 31 24 36 101M 15 24 36 301 WITH FASCIA 18 30 14 211 18 24 36 22 A9.20 11 A9.20 L2 L2 L2 L2 L2 L2 EQ EQCL A9.20 40 350 60 12 14 302 30 18 14 302 30 18 14 Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION 1/4" = 1'-0"8/15/2016 9:48:03 AMA5.12 185-01-00 8/15/16 INTERIOR ELEVATIONS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER 34D34C34B 1/4" = 1'-0"34A MANAGER'S OFFICE A35D35C35B 1/4" = 1'-0"35A STAFF TOILET 36D36C36B 1/4" = 1'-0"36A TECH WORKROOM 33D33C33B 1/4" = 1'-0"33A STAFF LOCKERS 32D32C32B 1/4" = 1'-0"32A RADIOLOGIST WORKROOM GC TO PROVIDE BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, INCLUDING OFOI 1/4" = 1'-0"31A STAFF BREAK ROOM 31B 31C 31D 1/4" = 1'-0"29A STRETCHER WAITING 29B 29C 29D 26D26C26B 1/4" = 1'-0"26A LARGE MAMMOGRAPHY 28D28C28B 1/4" = 1'-0"28A NURSE STATION 1/4" = 1'-0"27A CLEAN STORAGE 27B 27C 27D 1/4" = 1'-0"30A CORRIDOR G-128 A 30B 30C 30D CL 36F Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 1. ALL TYPICAL ACT CEILING HEIGHTS 8'-0" UNLESS OTHERWISE NOTED. 2. ALL TYPICAL ACT CEILING SHALL BE ACT-1, UNLESS OTHERWISE NOTED. 3. CEILINGS SHALL NOT BE INSTALLED WITHOUT REVIEWED MEP COORDINATION DRAWINGS AS REQUIRED BY THE PROJECT SPECIFICATIONS. 4. AT NO TIME SHALL THE CONTRACTOR ADJUST THE CEILING HEIGHT AS INDICATED ON DOCUMENTS WITHOUT REVIEW WITH ARCHITECT. ARCHITECT SHALL BE INFORMED OF ALL CEILING HEIGHT CONFLICTS WHEN DISCOVERED FOR REVIEW. 5. COORDINATE ALL SOFFITS ABOVE CABINETS WITH INTERIOR ELEVATIONS AND CASEWORK DETAILS. 6. ALL DEVICES SHALL BE ALIGNED AND CENTERED WITHIN GRID UNLESS OTHERWISE NOTED. 7. REFER TO ALL ENGINEERING CONSULTANT AND VENDOR DRAWINGS FOR ALL RELATED SCOPE FOR COORDINATION. SEE CEILING PLAN FOR HEIGHT6" MIN.VARIESCORNER BEAD 5/8" GYPSUM BOARD ACOUSTICAL CEILING SYSTEM 5/8" GYPSUM BOARD 3 5/8" METAL STUD TO UNDERSIDE OF STRUCTURE SEE CEILING PLAN FOR HEIGHT 5/8" GYPSUM BOARD CHANNELVARIESSEE CEILING PLAN FOR HEIGHT RIGID FURRING CHANNEL 5/8" GYPSUM BOARD METAL ANGLE CORNER BEAD 3 5/8" METAL STUD BRACE TO UNDERSIDE OF STRUCTURE 3 5/8" METAL STUD BRACE TO UNDERSIDE OF STRUCTURE WOOD BLOCKING ACOUSTICAL - CEILING SYSTEM 1/2" THREADED STEEL ROD TO EXISTING STRUCTURE EXISTING STRUCTURE CURTAIN TRACK ATTACHED TO BLOCKING ABOVE SEE CEILING PLAN FOR HEIGHT 5/8" GYPSUM BOARD 5/8" GYPSUM BOARD SEE CEILING PLAN FOR HEIGHT6" MIN.VARIES2" UON2" UON5/8" GYPSUM BOARD CORNER BEAD METAL CHANNEL 3 5/8" METAL STUD BRACE TO UNDERSIDE OF STRUCTURE 3 5/8" METAL STUD BRACE TO UNDERSIDE OF STRUCTURE 2'x2' SUPPLY DIFFUSER NEW CEILING GRID WITH NEW 2'x2' ACOUSTICAL PANEL CEILING NEW SOFFIT 1'x1' SUPPLY DIFFUSER 2'x2' RETURN REGISTER 1'x1' RETURN REGISTER EXIT SIGN SMOKE DETECTOR 2'x2' RECESSED LIGHT FIXTURE SPRINKLER EXISTING CEILING GRID WITH EXISTING 2'x2' ACOUSTICAL PANEL CEILING EXISTING SOFFIT LINEAR FLUSH MOUNTED LIGHT FIXTURE UNDER CABINET LIGHT FIXTURE NURSE CALL CURTAIN TRACK MOTION SENSOR SPEAKER WIRELESS ACCESS POINT 1'x4' RECESSED LIGHT FIXTURE PENDANT LIGHT FIXTURE INDIRECT WALL UPLIGHT/SCONCE CEILING MOUNTED EXAM LIGHT 7' - 2"7' - 2" EXAM 2 G-107 7' - 2" 7' - 2" 7' - 2" 7' - 2" 7' - 2" 7' - 2" 7' - 2" GOWNED SUB-WAITING G-110 PATIENT CHANGING ROOM 1 G-111D SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A PATIENT CHANGING ROOM 2 G-111B PATIENT CHANGING ROOM 3 G-111C BONE DENSITY G-113 INTERVIEW 2 G-117 RADIOLOGIST WORKROOM G-124 CLEAN WORK AREA G-126A STAFF TOILET G-130A LIAISON G-114C LARGE MAMMOGRAPHY G-120 SCOPE OF WORK 7' - 2" 6' - 2" ELECTRICAL CLOSET G-125 INTERVIEW 1 G-118 NAVIGATOR'S OFFICE G-116 EXAM 1 G-106 OFFICE G-108 PATIENT TOILET G-109 STEREOTACTIC G-105 STAFF BREAK ROOM G-123 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B STRETCHER WAITING G-127 NURSE STATION G-126 SUB WAITING G-119 7' - 2" MAMMOGRAPHY G-122 ULTRASOUND G-121 6' - 2" CORRIDOR G-111 CORRIDOR G-115C 8' - 6" 7' - 10" 7' - 10" 8' - 6" 4 7/8" 8 1/4" 4 7/8" 8 1/4" 12 A6.00 12 A6.00 7' - 2" 8' - 6"EQEQCORRIDOR G-128 EQEQ CORRIDOR G-119B SUB WAITING PATIENT TOILET G-119A MEN'S CHANGING & WAITING G-114 CORRIDOR G-115B CORRIDOR G-115B CORRIDOR G-115D 9"8' - 6" 7' - 6" 7' - 2" 7' - 2" 8' - 0" ACT-2 7' - 6" 10 A6.00 10 A6.00 EQEQEQEQEQEQ ALTERNATE 1 ALTERNATE 1 30 A6.00 TYP 30 A6.00 TYP 30 A6.00 TYP EQEQ CL EQEQ EQEQ CL CL EQ EQ CL 20 A6.00 20 A6.00 10 A6.00 7' - 2" 10 A6.00 7' - 6" 40 A6.00 40 A6.00 10 A6.00 10 A6.00 10 A6.00 10 A6.00 40 A6.00 10 A6.00 10 A6.00 10 A6.00 10 A6.00 10 A6.00 10 A6.00 40 A6.00 10 A6.00 10 A6.00 10 A6.00 10 A6.00 10 A6.00 40 A6.00 10 A6.00 11 A6.00 SEE CEILING PLAN FOR HEIGHT6" MIN.CORNER BEAD, TYP. 5/8" GYPSUM BOARD ACOUSTICAL CEILING SYSTEM 5/8" GYPSUM BOARD 3 5/8" METAL STUD TO UNDERSIDE OF STRUCTURE SEE CEILING PLAN FOR HEIGHT SCHEDULED LIGHT FIXTURE SCHEDULED PARTITION MINERAL PROFILE PANEL FEATURE WALL SEE CEILING PLAN FOR HEIGHT SEE CEILING PLAN FOR HEIGHT 5/8" GYPSUM BOARD CHANNEL SEE CEILING PLAN FOR HEIGHT ACOUSTICAL CEILING SYSTEM METAL ANGLE CORNER BEAD 3 5/8" METAL STUD BRACE TO UNDERSIDE OF STRUCTURE 3 5/8" METAL STUD BRACE TO UNDERSIDE OF STRUCTURE Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION As indicated 8/15/2016 9:48:05 AMA6.00 185-01-00 8/15/16 REFLECTED CEILING GENERAL NOTES, KEYS, LEGENDS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER GENERAL CEILING NOTES SCALE: SECTION DETAIL 1 1/2" = 1'-0" 10 CHANGE IN MATERIAL SCALE: SECTION DETAIL 1 1/2" = 1'-0" 11 CHANGE IN MATERIAL HEIGHT SCALE: SECTION DETAIL 1 1/2" = 1'-0" 30 CURTAIN TRACK SCALE: SECTION DETAIL 1 1/2" = 1'-0" 40 CHANGE IN CEILING CEILING PLAN KEY SCALE: 1/4" = 1'-0"1 REFLECTED CEILING PLAN SCALE: SECTION DETAIL 1 1/2" = 1'-0" 12 FEATURE WALL LIGHT FIXTURE POCKET SCALE: SECTION DETAIL 1 1/2" = 1'-0" 20 FEATURE CORRIDOR SOFFIT Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 2"3/4"1"1 15/16"1 15/16"VARIES4 7/8" AT 3 3/4" PARTITION6" AT 4 7/8" PARTITION6 5/8" AT 5 1/2" PARTITION6 3/4" AT 5 5/8" PARTITION7 1/4" AT 6 1/8" PARTITION8 1/4" AT 7 1/8" PARTITION8 3/8" AT 7 5/8" PARTITION8 3/4" AT 7 5/8" PARTITION9" AT 7 7/8" PARTITION9 5/8" AT 8 1/2" PARTITION9 3/4" AT 8 5/8" PARTITION-1/2" AT 1/4" GLASS 7/8" AT 5/8" GLASS 1 15/16"1 15/16"VARIES 4 7/8" AT 3 3/4" PARTITION 6" AT 4 7/8" PARTITION 6 5/8" AT 5 1/2" PARTITION 6 3/4" AT 5 5/8" PARTITION 7 1/4" AT 6 1/8" PARTITION 8 1/4" AT 7 1/8" PARTITION 8 3/8" AT 7 5/8" PARTITION 8 3/4" AT 7 5/8" PARTITION 9" AT 7 7/8" PARTITION 9 5/8" AT 8 1/2" PARTITION 9 3/4" AT 8 5/8" PARTITION 1/2"1/2"2"3/4"1 15/16"1 15/16"VARIES4 7/8" AT 3 3/4" PARTITION6" AT 4 7/8" PARTITION6 5/8" AT 5 1/2" PARTITION6 3/4" AT 5 5/8" PARTITION7 1/4" AT 6 1/8" PARTITION8 1/4" AT 7 1/8" PARTITION8 3/8" AT 7 5/8" PARTITION8 3/4" AT 7 5/8" PARTITION9" AT 7 7/8" PARTITION9 5/8" AT 8 1/2" PARTITION9 3/4" AT 8 5/8" PARTITION1/2"1/2"2"3/4"3/4"1" 1 15/16"1 15/16"VARIES 4 7/8" AT 3 3/4" PARTITION 6" AT 4 7/8" PARTITION 6 5/8" AT 5 1/2" PARTITION 6 3/4" AT 5 5/8" PARTITION 7 1/4" AT 6 1/8" PARTITION 8 1/4" AT 7 1/8" PARTITION 8 3/8" AT 7 5/8" PARTITION 8 3/4" AT 7 5/8" PARTITION 9" AT 7 7/8" PARTITION 9 5/8" AT 8 1/2" PARTITION 9 3/4" AT 8 5/8" PARTITION 1/2"1/2" 1/2" AT 1/4" GLASS 7/8" AT 5/8" GLASS 2"1" 1 15/16"1 15/16"VARIES 4 7/8" AT 3 3/4" PARTITION 6" AT 4 7/8" PARTITION 6 5/8" AT 5 1/2" PARTITION 6 3/4" AT 5 5/8" PARTITION 7 1/4" AT 6 1/8" PARTITION 8 1/4" AT 7 1/8" PARTITION 8 3/8" AT 7 5/8" PARTITION 8 3/4" AT 7 5/8" PARTITION 9" AT 7 7/8" PARTITION 9 5/8" AT 8 1/2" PARTITION 9 3/4" AT 8 5/8" PARTITION 1/2"1/2" 1/2" AT 1/4" GLASS 7/8" AT 5/8" GLASS2"3/4"3/4"1" 1 15/16"1 15/16"VARIES 4 7/8" AT 3 3/4" PARTITION 6" AT 4 7/8" PARTITION 6 5/8" AT 5 1/2" PARTITION 6 3/4" AT 5 5/8" PARTITION 7 1/4" AT 6 1/8" PARTITION 8 1/4" AT 7 1/8" PARTITION 8 3/8" AT 7 5/8" PARTITION 8 3/4" AT 7 5/8" PARTITION 9" AT 7 7/8" PARTITION 9 5/8" AT 8 1/2" PARTITION 9 3/4" AT 8 5/8" PARTITION 1/2"1/2"4"3/4"1/2" AT 1/4" GLASS 7/8" AT 5/8" GLASS1"1 15/16"1 15/16"VARIES4 7/8" AT 3 3/4" PARTITION6" AT 4 7/8" PARTITION6 5/8" AT 5 1/2" PARTITION6 3/4" AT 5 5/8" PARTITION7 1/4" AT 6 1/8" PARTITION8 1/4" AT 7 1/8" PARTITION8 3/8" AT 7 5/8" PARTITION8 3/4" AT 7 5/8" PARTITION9" AT 7 7/8" PARTITION9 5/8" AT 8 1/2" PARTITION9 3/4" AT 8 5/8" PARTITION1/2"1/2"3/4"-1/2" AT 1/4" GLASS 7/8" AT 5/8" GLASS 2"7' - 2"A VARIES SINGLE 7' - 2"B VARIES DOUBLE 7' - 2"C SINGLE WITH SIDELITE VARIES 4"2"2"VARIESD VARIES DOUBLE ACTING OR CASED OPENING 21 A9.10 21 A9.10 21 A9.10 20 A9.10 20 A9.10 20 A9.10 24 A9.10 23 A9.10 11 A9.10 22 A9.10 10 A9.10 13 A9.10 VARIESW VARIES WOOD SINGLE 14 A9.10 15 A9.10 VARIESWC VARIES WOOD CASED OPENING 34 A9.50 42 A9.50 DOOR AND WINDOW CONSTRUCTION: ACOUS ACOUSTICAL CORE WOOD AC ALUMINUM CLAD WOOD AL ALUMINUM HC HOLLOW CORE WOOD HM HOLLOW METAL LL LEAD LINED FRAME SC SOLID CORE WOOD SS STAINLESS STEEL TG TEMPERED SAFETY GLASS DOOR GLASS TYPE: -- NO GLASS REQUIRED CR CLEAR WIRED FR FIRE RATED PER SPECIFICATIONS IG INSULATING GLASS LG LAMINATED GLASS TF CLEAR TEMPERED FLOAT TI TEMPERED INSULATING LE LEAD GLASS FRAME CONSTRUCTION: AC ALUMINUM CLAD WOOD AL ALUMINUM PS PRESSED STEEL SS STAINLESS STEEL WD WOOD DOOR FACING AND FINISH: AF ALUMINUM FACTORY FINISH CC COPPER CLADDING CL HARDWOOD, TRANSPARENT FINISH MF METAL FACTORY FINISH MP METAL PAINTED WD WOOD PAINTED FIRE RATING: BLANK NO FIRE RATING REQUIRED A180 3 HOUR RATING ('A' LABEL REQUIRED) B60 1 HOUR RATING (B LABEL REQUIRED) B90 1- 1/2 HOUR RATING ('B' LABEL REQUIRED) C45 3/4 HOUR ('C' LABEL REQUIRED) 20 1/3 HOUR RATING 30 1/2 HOUR RATING REMARKS: 1. TRANSOM OR SIDELIGHT ADJACENT 2. SPECIAL HEIGHT DOOR 3. SPECIAL ALUMINUM DOOR AND FRAME 4. SECURITY TIE IN REQUIREMENTS 5. SPECIAL WOOD DOOR AND FRAME 6. SOUND GASKETING 7. WEATHERING STRIP 8. MAGNETIC HOLD OPENS 9. LIGHT GASKET 10. FIELD MEASUREMENT REQUIRED 11. DOUBLE ACTING REMOVE FRAME STOP 12. LEAD LINING REQUIRED 13. AUTOMATIC DOORS 14. CODE ACCESS HARDWARE 15. EXISTING DOOR 16. STAINLESS STEEL KICK PLATE 17. ROTON HINGE 4 7/8" AT 3 3/4" PARTITION 6" AT 4 7/8" PARTITION 6 5/8" AT 5 1/2" PARTITION 6 3/4" AT 5 5/8" PARTITION 7 1/4" AT 6 1/8" PARTITION 8 1/4" AT 7 1/8" PARTITION 8 3/8" AT 7 5/8" PARTITION 8 3/4" AT 7 5/8" PARTITION 9" AT 7 7/8" PARTITION 9 5/8" AT 8 1/2" PARTITION 9 3/4" AT 8 5/8" PARTITION 1/2"1/2"2"4 7/8" AT 3 3/4" PARTITION6" AT 4 7/8" PARTITION6 5/8" AT 5 1/2" PARTITION6 3/4" AT 5 5/8" PARTITION7 1/4" AT 6 1/8" PARTITION8 1/4" AT 7 1/8" PARTITION8 3/8" AT 7 5/8" PARTITION8 3/4" AT 7 5/8" PARTITION9" AT 7 7/8" PARTITION9 5/8" AT 8 1/2" PARTITION9 3/4" AT 8 5/8" PARTITION1/2"1/2"2" F FGFLUSH FULL GLAZED HG HALF GLAZED N NARROW GLAZED TEMPERED GLAZING 3' - 0"TEMPERED GLAZING 2' - 1"TEMPERED GLAZING4" SCHEDULED LEAF 6"6"10"8"10"6"6" 1 WINDOW - NURSE STATION 21 A9.10 20 A9.10 2 WINDOW - STEREOTACTIC 21 A9.10 20 A9.10 TEMPERED GLAZING LEAD LINED GLAZING 1/16" EQUIVALENT6'-0"4'-6"3'-6"4'-0"1/4" WOOD REVEAL, TYP. 3/4" HARDWOOD, TYP. 6 1/2" SCHEDULED PARTITION10"1/4" WOOD REVEAL, TYP. 3/4" HARDWOOD, TYP.6 1/2"SCHEDULED PARTITION 3" Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION As indicated 8/15/2016 9:48:07 AMA9.10 185-01-00 8/15/16 DOOR HARDWARE, FRAME TYPES & DETAILS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER SCALE: SECTION DETAIL 6" = 1'-0" 11 TYPICAL GLAZED DOOR JAMB SCALE: SECTION DETAIL 6" = 1'-0" 21 DOOR FRAME HEAD SCALE: SECTION DETAIL 6" = 1'-0" 20 DOOR FRAME JAMB SCALE: SECTION DETAIL 6" = 1'-0" 22 GLAZED OPENING FRAME HEAD SCALE: SECTION DETAIL 6" = 1'-0" 12 GLAZED OPENING FRAME SILL SCALE: SECTION DETAIL 6" = 1'-0" 10 GLAZED OPENING FRAME WITH 4" SILL SCALE: SECTION DETAIL 6" = 1'-0" 13 GLAZED OPENING JAMB DOOR FRAME TYPES DOOR ABBREVIATIONS SCALE: SECTION DETAIL 6" = 1'-0" 24 DOUBLE ACTING OR CASED DOOR FRAME HEAD SCALE: SECTION DETAIL 6" = 1'-0" 23 DOUBLE ACTING OR CASED DOOR FRAME JAMB DOOR FRAME HDWR COMMENTSMARK ROOM NAME OPERATION OPENING PANEL TYPE MATLWIDTH HEIGHT TYPE MATL THICK CONFIG PANEL WIDTH LEAF TYPE LEAF WIDTH G-105-A STEREOTACTIC Double - Unequal 4' - 6" 7' - 0" F SC 1 3/4" UNEQUAL 3' - 6" F 1' - 0" B PS 17 CLASSROOM LOCKSET, HOLD-OPEN CLOSER G-106-A EXAM 1 Single - Hinged 3' - 6" 7' - 0" F SC 1 3/4"SINGLE 3' - 6"A PS 19 PASSAGE LOCKSET, HOLD-OPEN CLOSER G-107-A EXAM 2 Single - Hinged 3' - 6" 7' - 0" F SC 1 3/4"SINGLE 3' - 6"A PS 19 PASSAGE LOCKSET, HOLD-OPEN CLOSER G-108-A OFFICE Single - Hinged 3' - 0" 7' - 0" F SC 1 3/4"SINGLE 3' - 0"A PS 05 OFFICE LOCKSET G-109-A PATIENT TOILET Single - Double Acting 3' - 6" 7' - 0" F SC 1 3/4" SINGLE 3' - 6"D PS 03 PRIVACY LOCKSET, DOUBLE ACTING, THUMB TURN INDICATOR, GASKETING G-110-A GOWNED SUB-WAITING Cased Opening 3' - 6" 7' - 6"1 3/4"WC WD CASED OPENING, NO DOOR PANEL REQUIRED, REFER TO A9.50 HARDWOOD DOOR DETAILS G-110-B GOWNED SUB-WAITING Cased Opening 3' - 6" 7' - 6"1 3/4"WC WD CASED OPENING, NO DOOR PANEL REQUIRED G-111A-A CHANGING PATIENT TOILET Single - Double Acting 3' - 6" 7' - 0" F SC 1 3/4" SINGLE 3' - 6"D PS 03 PRIVACY LOCKSET, DOUBLE ACTING, THUMB TURN INDICATOR, GASKETING G-111B-A PATIENT CHANGING ROOM 2 Single - Hinged 3' - 6" 7' - 0" F SC 1 3/4" SINGLE 3' - 6"A PS 18 PRIVACY LOCKSET, THUMB TURN INDICATOR G-111C-A PATIENT CHANGING ROOM 3 Single - Double Acting 3' - 0" 7' - 0" F SC 1 3/4" SINGLE 3' - 0"D PS 03 PRIVACY LOCKSET, DOUBLE ACTING, THUMB TURN INDICATOR, GASKETING G-111D-A PATIENT CHANGING ROOM 1 Single - Double Acting 3' - 0" 7' - 0" F SC 1 3/4" SINGLE 3' - 0"D PS 03 PRIVACY LOCKSET, DOUBLE ACTING, THUMB TURN INDICATOR, GASKETING G-112-A SOILED HOLDING ROOM Single - Hinged 3' - 0" 7' - 0" F SC 1 3/4" SINGLE 3' - 0"A PS 01 STORAGE LOCKSET G-113A BONE DENSITY Double - Unequal 4' - 6" 7' - 0" F SC 1 3/4" UNEQUAL 3' - 6" F 1' - 0" B PS 17 CLASSROOM LOCKSET, HOLD-OPEN CLOSER G-114-A MEN'S CHANGING & WAITING Single - Hinged 3' - 6" 7' - 0" F SC 1 3/4" SINGLE 3' - 6"A PS 09 PRIVACY LOCKSET, THUMB TURN INDICATOR G-115A-A CORRIDOR Double - Egress 6' - 0" 7' - 0" F SC 1 3/4" PAIR 3' - 0"B PS 10 NO LOCKING G-115A-B CORRIDOR Cased Opening 3' - 0" 7' - 0" SC 1 3/4"D PS N/A G-115B-A CORRIDOR Double - Egress 6' - 0" 7' - 0" F SC 1 3/4" PAIR 3' - 0"B PS 11 POWER OPERATOR WITH PROX CARD ACCESS G-116-A NAVIGATOR'S OFFICE Single - Hinged 3' - 6" 7' - 0" F SC 1 3/4" SINGLE 3' - 6"A PS 06 OFFICE LOCKSET G-117-A INTERVIEW 2 Single - Hinged 3' - 6" 7' - 0" F SC 1 3/4" SINGLE 3' - 6"A PS 06 OFFICE LOCKSET G-118-A INTERVIEW 1 Single - Hinged 3' - 6" 7' - 0" F SC 1 3/4" SINGLE 3' - 6"A PS 06 OFFICE LOCKSET G-119-A SUB WAITING Single - Hinged 3' - 6" 7' - 6" FG SC 1 3/4" SINGLE 3' - 6"W WD 12 POWER OPERATOR WITH PROX CARD ACCESS, WOOD FRAME, REFER TO A9.50 HARDWOOD DOOR DETAILS G-119-B SUB WAITING Single - Hinged 3' - 6" 7' - 0" N SC 1 3/4" SINGLE 3' - 6"A PS 03 PASSAGE LOCKSET, HOLD-OPEN CLOSER G-119A-A SUB WAITING PATIENT TOILET Single - Double Acting 3' - 6" 7' - 0" F SC 1 3/4" SINGLE 3' - 6"D PS 21 PRIVACY LOCKSET, DOUBLE ACTING, THUMB TURN INDICATOR, GASKETING G-119B-A CORRIDOR Cased Opening 3' - 6" 7' - 6"1 3/4"D PS CASED OPENING, NO DOOR PANEL REQUIRED G-119B-B CORRIDOR Single - Hinged 3' - 6" 7' - 0" N SC 1 3/4" SINGLE 3' - 6"A PS 13 PASSAGE LOCKSET G-120-A LARGE MAMMOGRAPHY Double - Unequal 4' - 6" 7' - 0" F SC 1 3/4" UNEQUAL 3' - 6" F 1' - 0" B PS 17 CLASSROOM LOCKSET, HOLD-OPEN CLOSER G-121-A ULTRASOUND Double - Unequal 4' - 6" 7' - 0" F SC 1 3/4" UNEQUAL 3' - 6" F 1' - 0" B PS 17 CLASSROOM LOCKSET, HOLD-OPEN CLOSER G-122-A MAMMOGRAPHY Double - Unequal 4' - 6" 7' - 0" F SC 1 3/4" UNEQUAL 3' - 6" F 1' - 0" B PS 17 CLASSROOM LOCKSET, HOLD-OPEN CLOSER G-123-A STAFF BREAK ROOM Single - Hinged 3' - 0" 7' - 0" F SC 1 3/4" SINGLE 3' - 0"A PS 02 CLASSROOM LOCKSET G-124-A RADIOLOGIST WORKROOM Single - Hinged 3' - 0" 7' - 0" F SC 1 3/4" SINGLE 3' - 0"A PS 08 OFFICE LOCKSET, SOUND GASKETING G-125-A ELECTRICAL CLOSET Double - Hinged 8' - 0" 7' - 0" F SC 1 3/4" PAIR 4' - 0"B PS 20 STORAGE LOCKSET, MANUAL FLUSH BOLT G-126A-A CLEAN WORK AREA Single - Hinged 3' - 0" 7' - 0" F SC 1 3/4" SINGLE 3' - 0"A PS 04 STORAGE LOCKSET G-127-A STRETCHER WAITING Double - Unequal 4' - 6" 7' - 0" F SC 1 3/4" UNEQUAL 3' - 6" F 1' - 0" B PS 17 CLASSROOM LOCKSET, HOLD-OPEN CLOSER G-128-A CORRIDOR Double - Egress 6' - 0" 7' - 0" F SC 1 3/4" PAIR 3' - 0"B PS 14 PROX CARD ACCESS G-130-A TECH WORKROOM Single - Hinged 3' - 0" 7' - 0" N SC 1 3/4" SINGLE 3' - 0"A PS 15 CLASSROOM LOCKSET, HOLD-OPEN CLOSER G-130A-A STAFF TOILET Single - Hinged 3' - 0" 7' - 0" F SC 1 3/4" SINGLE 3' - 0"A PS 16 PRIVACY LOCKSET, THUMB TURN INDICATOR G-130B-A MANAGER'S OFFICE Single - Hinged 3' - 0" 7' - 0" F SC 1 3/4" SINGLE 3' - 0"A PS 07 OFFICE LOCKSET DOOR PANEL TYPES WINDOW SCHEDULE SCALE: SECTION DETAIL 6" = 1'-0" 14 WOOD CASED FRAME HEAD SCALE: SECTION DETAIL 6" = 1'-0" 15 WOOD CASED FRAME JAMB Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 BOOKENDS WHERE REQUIRED 3/4" PLYWOOD WITH PLAM SCHEDULED SHELVING BRACKET, TYP. LOCATER CLIP ATTACHED TO SHELF (TYP.) 48" SCHEDULED SHELVING STANDARD - CUT TO SUIT FIELD CONDITIONS IF REQUIRED CLEAR HEIGHT BETWEEN SHELVES1' - 1" TYP.1' - 0" TYP.6" TYP.PROVIDE BLOCKING IN WALL 3/4" PLYWOOD WITH PLAM 1/2" SOLID SURFACE BACKSPLASH 1/2" SOLID SUFACE COUNTERTOP WITH 1" PLYWOOD SUBSTRATE EASED EDGE, TYP BLOCKING 1 1/2"SCHEDULED SUPPORT BRACKETS SCHEDULED WALL BASE PROVIDE BLOCKING IN WALL REFER TO CASEWORK TAG IN ELEVATIONREFER TO CASEWORK TAG IN ELEVATION 4"JOINT SEALANT 1/2" SOLID SURFACE BACKSPLASH 1/2" SOLID SUFACE COUNTERTOP WITH 1" PLYWOOD BACKING 2" EASED EDGE, TYP BLOCKING 1 1/2"REFER TO CASEWORK TAG IN ELEVATIONREFER TO CASEWORK TAG IN ELEVATION 4"JOINT SEALANT TOE KICK HEIGHT TOE KICK DEPTH FACE OF CABINET BELOW SCHEDULED WALL BASE 3"4"3/4" PLYWOOD WITH PLAM (2) LAYERS OF 3/4" PLYWOOD WITH PLAM WOOD BLOCKING SCHEDULED SUPPORT BRACKETS SCHEDULED WALL BASE PROVIDE BLOCKING IN WALL4"T MOULDING PROFILE EDGE REFER TO CASEWORK TAG IN ELEVATION1 1/2"REFER TO CASEWORK TAG IN ELEVATION 3/4" PLYWOOD WITH PLAM (2) LAYERS OF 3/4" PLYWOOD WITH PLAM WOOD BLOCKING PROVIDE BLOCKING IN WALL4"T MOULDING PROFILE EDGE REFER TO CASEWORK TAG IN ELEVATION1 1/2"REFER TO CASEWORK TAG IN ELEVATION TOE KICK HEIGHT TOE KICK DEPTH FACE OF CABINET BELOW SCHEDULED WALL BASE 3"4"3/4" SCHEDULED WALL BASE ADJ. FOOT (TYP.) 3/4" PLYWOOD (SCRIBE TO FLOOR)4"3/4" PLYWOOD 3/4" PLYWOOD WITH PLAM8"7"3"5"1' - 8 1/2" 1/2" x 4" SOLID SURFACE BACKSPLASH 1/2" SOLID SUFACE COUNTERTOP WITH 1" PLYWOOD BACKING EASED EDGE, TYP BLOCKING, TYP.3'-0"6"8"7"7"8"SCHEDULED WALL BASE ADJ. FOOT (TYP.) 3/4" PLYWOOD (SCRIBE TO FLOOR)4"3/4" PLYWOOD 3/4" PLYWOOD WITH PLAM7' - 0"5"8"8"8"6"1'-9"7"7"7"SCHEDULED SINK 4"3" 3/4" x 4" SOLID SURFACE BACKSPLASH 3/4" SOLID SUFACE COUNTERTOP WITH 3/4" PLYWOOD BACKING EASED EDGE, TYP BLOCKING, TYP. 2'-1" SCHEDULED WALL BASE ADJ. FOOT (TYP.) 3/4" PLYWOOD (SCRIBE TO FLOOR) 3/4" PLYWOOD 3/4" PLYWOOD W/ PLAM 2'-10"1 1/2"5"FIXED PANEL SCHEDULED WALL BASE ADJ. FOOT (TYP.) 3/4" PLYWOOD (SCRIBE TO FLOOR) 3"4"1/2" x 4" SOLID SURFACE BACKSPLASH 1/2" SOLID SUFACE COUNTERTOP WITH 1" PLYWOOD BACKING EASED EDGE, TYP BLOCKING, TYP.1 1/2"2'-10"2'-1"2"SCHEDULED WASTEBASKET 3/4" PLYWOOD 3/4" PLYWOOD WITH PLAMCLEAR5"1/4" ALUMINUM TRIM SCHEDULED WALL BASE ADJ. FOOT (TYP.) 3/4" PLYWOOD (SCRIBE TO FLOOR)4"3/4" PLYWOOD 3/4" PLYWOOD WITH PLAM8"7"3"5"1' - 8 1/2" 1/2" x 4" SOLID SURFACE BACKSPLASH 1/2" SOLID SUFACE COUNTERTOP WITH 1" PLYWOOD BACKING EASED EDGE, TYP BLOCKING, TYP.3'-0"6"1'-4"1'-2"BLOCKING, TYP. 3/4" PLYWOOD WITH PLAM 2' - 6"WALL MOUNTED PAPER TOWEL DISPENSER, SOAP DISPENSER AND GLOVE HOLDER1'-4"1' - 1"3/4" PLYWOOD WITH PLAM DOOR 3/4" PLYWOOD WITH PLAM CLEAR 1'-2" SEE CEILING PLAN FOR HEIGHT6" MIN.VARIESACOUSTICAL CEILING SYSTEM 5/8" GYPSUM BOARD 3 5/8" METAL STUD TO UNDERSIDE OF STRUCTURE 2"SCHEDULED TILE BACKSPLASH 1/4" SCHEDULED ALUMINUM TRIM 1/4" SCHEDULED ALUMINUM TRIM 30 A9.20 SCHEDULED TILE BACKSPLASH 3/4" HARDWOOD WITH 3/4" PLYWOOD BACKING HARDWOOD BULLNOSE POFILE EDGE BLOCKING, TYP.1'-6"2'-0" SCHEDULED WALL BASE, TYP.4"2'-0"4'-0"23 A9.20 3/4" HARDWOOD WITH 3/4" PLYWOOD BACKING 2" RADIUS CORNER 1/2" SOLID SUFACE COUNTERTOP WITH 1" PLYWOOD BACKING EASED EDGE, TYP BLOCKING, TYP.1 1/2"3'-4"2'-1" SCHEDULED SOILED LINEN 3/4" PLYWOOD WITH PLAM 1/2"1'-3" EQ EQCL 1'-1"1'-0"1'-3"1'-3" CL CL 33 A9.20 EASED CORNERS, TYP. 25 A9.20 3/4"3'-11" 3/4" SOLID SURFACE COUNTERTOP WITH 3/4" PLYWOOD SUBSTRATE COUNTERTOP BELOW R 10" 2' - 1"2' - 6"1' - 3"ALIGN3/4" SOLID SURFACE DIVIDER 4"4"1'-2"1'-3"1'-3"1'-2" 1/4" TYP.1/4" TYP.2"CL CL CL Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION 1 1/2" = 1'-0"8/15/2016 9:48:08 AMA9.20 185-01-00 8/15/16 CASEWORK MENU AND DETAILS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER SCALE: SECTION DETAIL 1 1/2" = 1'-0" 10 ADJUSTABLE SHELVES- SECTION SCALE: SECTION DETAIL 1 1/2" = 1'-0" 12 SOILD SURFACE COUNTERTOP WITH BRACKETS SCALE: SECTION DETAIL 1 1/2" = 1'-0" 11 SOILD SURFACE COUNTERTOP ABOVE CABINETS SCALE: SECTION DETAIL 1 1/2" = 1'-0" 14 PLAM COUNTERTOP WITH BRACKETS SCALE: SECTION DETAIL 1 1/2" = 1'-0" 13 PLAM COUNTERTOP ABOVE CABINETS SCALE: SECTION DETAIL 1 1/2" = 1'-0" 20 4 DRAWER SECTION SCALE: EXTERIOR SECTION DETAIL 1 1/2" = 1'-0" 35 EXAM ROOM CABINET SCALE: SECTION DETAIL 1 1/2" = 1'-0" 15 FIXED FULL PANEL SINK FASCIA SCALE: SECTION DETAIL 1 1/2" = 1'-0" 22 WASTEBASKET CABINET SCALE: SECTION DETAIL 1 1/2" = 1'-0" 21 FILE CABINET DRAWERS SCALE: SECTION DETAIL 1 1/2" = 1'-0" 30 GLOVE & PAPER TOWEL CABINETS SCALE: SECTION DETAIL 1 1/2" = 1'-0" 31 TILE WORK CALL OUT SCALE: SECTION DETAIL 1 1/2" = 1'-0" 23 CHANGING ROOM BENCH SCALE: SECTION DETAIL 1 1/2" = 1'-0" 24 CHANGING ROOM BENCH SCALE: SECTION DETAIL 1 1/2" = 1'-0" 33 SOILED LINEN HAMPER CABINET SCALE: SECTION DETAIL 1 1/2" = 1'-0" 32 SOILED LINEN COUNTER SCALE: SECTION DETAIL 1 1/2" = 1'-0" 34 RADIOLOGY WORKROOM FIN SCALE: SECTION DETAIL 1 1/2" = 1'-0" 25 RADIOLOGY WORKROOM FIN SCALE: SECTION DETAIL 1 1/2" = 1'-0" 40 TECH WORKROOM SHELF Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 11 A9.30 13 A9.30 CL CL CL CL 5"5" 12 A9.30 2" RADIUS OUTSIDE CORNERS, TYP. CLCENTERLINE OF PARTITION BELOW A9.30 30 A9.3020 (2) LAYERS OF 3/4" PLYWOOD WITH PLAM COUNTER PLYWOOD WITH PLAM BACK/SIDESPLASH, TYP. CENTERLINE OF PARTITION BELOW TACKABLE SURFACE DIVIDER, TYP. CL CL CL 2' - 7 1/4" +/-4' - 2"4' - 2"1' - 3"1' - 3"4' - 2"4' - 2"2' - 7 1/4" +/-(2) LAYERS OF 3/4" PLYWOOD WITH PLAM COUNTER (2) LAYERS OF 3/4" PLYWOOD WITH PLAM T-MOLDING EDGE, TYP BLOCKING, TYP. EQ EQCL 5/8" GYPSUM WALL BOARD 3'-0"SCHEDULED WALL BASE, TYP. TACKABLE SURFACE ON 3/4" PLYWOOD 1/4" ALUMNIUM CHANNEL 4"4 5/8" (1) LAYER OF 3/4" PLYWOOD WITH PLAM 3/4" ALUMINUM CHANNEL (2) LAYERS OF 3/4" PLYWOOD WITH PLAM T-MOLDING EDGE, TYP 4"TACKABLE SURFACE ON 3/4" PLYWOOD WITH ALUMINUM FRAME 4"(1) LAYER OF 3/4" PLYWOOD WITH PLAM BACKSPLASH, TYP. BLOCKING 3" SCHEDULED WALL BASE SCHEDULED BASE CABINET CL 13 A9.30 11 A9.30 12 A9.30 COUTNER ABOVE CENTERLINE OF PARTITION BELOW 3/4" PLYWOOD WITH PLAM. CENTERLINE OF PARTITION BELOW BLOCKING, TYP.5"5" GROMMETS, TYP.4' - 0"4' - 0"SCHEDULED WALL BASE 4"4"FINISHED END PANEL 3" SCHEDULED BASE CABINET SCHEDULED PARTITION (2) LAYERS OF 3/4" PLYWOOD WITH PLAM T-MOLDING EDGE, TYP TACKABLE SURFACE ON 3/4" PLYWOOD WITH ALUMINUM FRAME (1) LAYER OF 3/4" PLYWOOD WITH PLAM BACKSPLASH, TYP. BLOCKING GROMMET, TYP. CL 2"2" MOBILE PED MOBILE PED MOBILE PED SCANNER CPU SCANNER CPU SCANNER CPU 3/4"3' - 0"4"8"2' - 4"1' - 0"8"TACKABLE SURFACE DIVIDER WITH FRAME BACKSPLASH SCHEDULED BASE CABINET 1" 1" MOBILE PED MOBILE PEDMOBILE PED SCANNER CPU SCANNER CPU SCANNER CPU Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION As indicated 8/15/2016 9:48:10 AMA9.30 185-01-00 8/15/16 CUSTOM CASEWORK DETAILS - TECH WORKROOM COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER SCALE: PLAN DETAIL 1" = 1'-0"22 TECH WORKSTATION COUNTERTOP SCALE: SECTION DETAIL 1 1/2" = 1'-0" 13 TECH WORKROOM WORKSTATION SCALE: SECTION DETAIL 1 1/2" = 1'-0" 12 TECH WORKROOM WORKSTATION SCALE: SECTION DETAIL 1" = 1'-0"21 TECH WORKSTATION FRAMING PLAN SCALE: SECTION DETAIL 1 1/2" = 1'-0" 11 TECH WORKROOM WORKSTATION AT COPIER SCALE: SECTION DETAIL 1" = 1'-0" 30 TECH WORKROOM B Copy 1 SCALE: SECTION DETAIL 1 1/2" = 1'-0" 10 COPIER AREA SCALE: SECTION DETAIL 1" = 1'-0"20 TECH WORKROOM D Copy 1 Issuance Schedule Number Date Description 9"6" 6" CL3'-5"CL CL 1'-2"1'-6"1'-0"1'-0" 3/4" HARDWOOD 2'-0"5'-2" EQ EQ EQ EQ EQ EQ EQ 6"6"EQ EQ EQ EQ EQ EQ SCHEDULED COAT HOOKS EASED EDGES, TYP. WALL MOUNTED WITH Z-CLIPS 20 A9.40 12 A6.00 20 A9.40 LINE OF SOFFIT FINISHED FLOOR GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION 12 A6.00 20 A9.40 LINE OF SOFFIT GRAIN DIRECTION GRAIN DIRECTIONGRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION GRAIN DIRECTION 1/2" SOLID SURFACE ON 3/4" PLYWOOD EASED EDGE 4"SCHEDULED PARTITION MINERAL PROFILE PANEL FEATURE WALL 2" FINISHED FLOOR 3/4" PLYWOOD WITH PLAM (2) LAYERS OF 3/4" PLYWOOD WITH PLAM WOOD BLOCKING SCHEDULED SUPPORT BRACKETS SCHEDULED WALL BASE PROVIDE BLOCKING IN WALL4"T MOULDING PROFILE EDGE 2'-6"1 1/2"2'-1"2' - 1"2' - 1"4'-0"2' - 8" R 2 ' - 0 "CL CL EQEQ3'-5"6"8"3'-9"3' - 0" CL CL CL CL 21 A9.40 10" COUNTERTOP ABOVE GROMMETS ABOVE, TYP. SCHEDULED BRACKETS, TYP. HAFELE SUPPORT LEG, SINGLE COLUMN 114 R 2' - 0"4'-0"2'-1"2'-1"21 A9.40 2'-8" CL CL CL CL 3"3"3"3" (1) LAYER OF 3/4" PLYWOOD WITH PLAM GROMMETS, TYP. (2) LAYERS OF 3/4" PLYWOOD WITH PLAM COUNTER 3'-5"2'-0"6'-0"Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION As indicated 8/15/2016 9:48:11 AMA9.40 185-01-00 8/15/16 INTERIOR DETAILS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER SCALE: SECTION DETAIL 1 1/2" = 1'-0" 11 HEADWALL CALLOUT SCALE: SECTION DETAIL 1 1/2" = 1'-0" 10 COAT HOOKS SCALE: SECTION DETAIL 1" = 1'-0" 30 WAITING ROOM MODULAR ARTS WALL SCALE: SECTION DETAIL 1" = 1'-0" 12 GOWNED SUB WAITING MODULAR ARTS WALL SCALE: SECTION DETAIL 3" = 1'-0" 20 FEATURE WALL TYPICAL BASE SCALE: SECTION DETAIL 1 1/2" = 1'-0" 21 MANAGER'S OFFICE DESK SCALE: SECTION DETAIL 1 1/2" = 1'-0" 32 MANAGER'S OFFICE DESK SCALE: SECTION DETAIL 1 1/2" = 1'-0" 31 GROUND FLOOR - MANAGER'S DESK Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 31 A9.50 30 A9.50 10 A9.50 20 A9.50 32 A9.50 40 A9.50 41 A9.50 8' - 0"6'-7" +/-5' - 6 1/2"1' - 1 1/4"6 1/2"31 A9.50 30 A9.50 10 A9.50 34 A9.50 42 A9.50 33 A9.50 20 A9.50 OPEN TO BEYOND 8' - 10"8' - 0"1' - 1 1/4"5' - 6 1/2"6 1/2"1/4" WOOD REVEAL 3/4" HARDWOOD BASE CL 1"1/4" CAULK JOINT, TYP.4"1/2"6 1/2"BLOCKING, TYP. 1/2" TEMPERED GLAZING GLAZING HARDWOOD SILL AND WINDOW STOP 3/4" HARDWOOD5"2"4"EQEQCL SCHEDULED PARTITION BLOCKING, TYP. 1" PLYWOOD FILLER HARDWOOD DOOR FRAME 3/4" HARDWOOD 1/4" CAULK JOINT, TYP.5"4"EQEQCL 2" SCHEDULED PARTITION BLOCKING, TYP. 1" PLYWOOD FILLER HARDWOOD DOOR FRAME 3/4" HARDWOOD 1/4" CAULK JOINT, TYP. SCHEDULED DOOR CL 2 1/2" 2 1/2" 5"6"1/4" WOOD REVEAL BLOCKING, TYP. 1/4" PLYWOOD FILLER HARDWOOD FRAME 3/4" HARDWOOD 1/2"3 1/4"SCHEDULED CEILING 1/4" WOOD REVEAL CL 2 1/2" 2 1/2" BLOCKING, TYP. 1/4" PLYWOOD FILLER SCHEDULED DOOR HARDWOOD FRAME 3/4" HARDWOOD 1/2"3 1/4"6"SCHEDULED CEILING BLOCKING, TYP. 1/4" WOOD REVEAL 1/4" PLYWOOD FILLER 1/2" TEMPERED GLAZING GLAZING HARDWOOD SILL AND WINDOW STOP 3/4" HARDWOOD CL 2 1/2" 2 1/2" 5"4"6"1/2"SCHEDULED CEILING CL 2 1/2"2 1/2"2 1/2"5" BLOCKING, TYP. 1/2" TEMPERED GLAZING GLAZING HARDWOOD SILL AND WINDOW STOP 3/4" HARDWOOD1/2"1/4" WOOD REVEALCL2 1/2"2 1/2"6 1/4"5"2" BLOCKING, TYP. 1/2" PLYWOOD FILLER HARDWOOD DOOR FRAME 3/4" HARDWOOD 1/2" TEMPERED GLAZING GLAZING CL2 1/2"2 1/2"5"2" 1/4" WOOD REVEAL BLOCKING, TYP. 1/2" PLYWOOD FILLER HARDWOOD DOOR FRAME 3/4" HARDWOOD 1/2" TEMPERED GLAZING GLAZING SCHEDULED DOOR 6 1/4" CL5"2 1/2"2 1/2"4 1/2" +/- 3/4" SCHEDULED PARTITION WAITING ROOM G-119 CORRIDOR BLOCKING, TYP. 1/4" WOOD REVEAL 1" PLYWOOD FILLER 1/2" TEMPERED GLAZING GLAZING HARDWOOD SILL AND WINDOW STOP 3/4" HARDWOOD 1/4" CAULK JOINT, TYP. Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION As indicated 8/15/2016 9:48:12 AMA9.50 185-01-00 8/15/16 HARDWOOD DOOR DETAILS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER SCALE: SECTION DETAIL 1 1/2" = 1'-0" 11 SUB WAITING ROOM DOOR SCALE: SECTION DETAIL 1 1/2" = 1'-0" 12 GOWNED SUB-WAITING ROOM DOOR SCALE: SECTION DETAIL 3" = 1'-0" 10 WINDOW BASE SCALE: SECTION DETAIL 3" = 1'-0" 42 WAITING ROOM AT SIDE OF CASED OPENING SCALE: SECTION DETAIL 3" = 1'-0" 41 WAITING ROOM AT SIDE OF DOOR SCALE: SECTION DETAIL 3" = 1'-0"34 WAITING ROOM AT TOP OF CASED OPENING SCALE: SECTION DETAIL 3" = 1'-0" 40 WAITING ROOM AT TOP OF DOOR SCALE: SECTION DETAIL 3" = 1'-0"31 WINDOW HEAD SCALE: SECTION DETAIL 3" = 1'-0"30 WINDOW CASING SCALE: SECTION DETAIL 3" = 1'-0"33 WAITING ROOM IN BETWEEN WINDOWS AND CASED OPENING SCALE: SECTION DETAIL 3" = 1'-0"32 WAITING ROOM IN BETWEEN WINDOWS AND DOOR SCALE: SECTION DETAIL 3" = 1'-0" 20 WINDOW JAMB Issuance Schedule Number Date Description 20 A9.60 2" RADIUS OUTSIDE CORNERS, TYP.7'-5"EQEQEQACRYLIC COUNTERTOP ALIGN SLIDING GLAZED PANEL W/ RECESSED GUIDE/CHANNEL CR LAWRENCE CRL 50 S2 FIXED GLAZED PANEL SLIDING GLAZED PANEL W/ RECESSED GUIDE/CHANNEL CR LAWRENCE CRL 50 S2 CL CL 3 1/2"3 1/2"4'-1" ACRYLIC COUNTERTOP SEAM ACRYLIC COUNTERTOP SEAM HARDWOOD FRAME, TYP. TYP. 1/2"3' - 3 1/2"1' - 1 1/4"2' - 9" 10 1/2"2' - 6"23 A9.60 3'-10" 6"4"21 A9.60 31 A9.60 32 A9.60 31 A9.50 3/4" HARDWOOD PANEL1' - 1 1/4"EQ EQ EQCLCL 7'-0 1/2" 4"1'-4 1/2" 9'-0" 22 A9.60 30 A9.60 3/4" HARDWOOD PANEL 3/4" HARDWOOD PANEL 1/4" REVEAL 1/4" REVEAL 3 1/2"3 1/2" 1" ACRYLIC COUNTERTOP WITH 1" PLYWOOD SUBSTRATE EASED EDGE, TYP SUPPORT BRACKETS SCHEDULED WALL BASE SCHEDULED PARTITION CHAMFER PLYWOOD, PAINT SEMIGLOSS WHITE FLUSH MOUNTED SUPPORT BRACKETS BLOCKING, TYP. ATTACH FLUSH MOUNTED SUPPORT BRACKET TO IN WALL SOLID BLOCKING SUB WAITING G-119 LIAISON G-114C 4'-1"2'-6"3/4" HARDWOOD PANEL ON Z- CLIPS 3/4" THICK HARDWOOD WALL BASE, TYP. SCHEDULED PARTITION RECESSED ALUMINUM CHANNEL EASED EDGE, TYP. 1/4" CAULK JOINT, TYP. 5/8" GYPSUM WALL BOARD 1" ACRYLIC COUNTERTOP WITH 1" PLYWOOD SUBSTRATE CL 4" 6 1/4" CHAMFER PLYWOOD, PAINT SEMIGLOSS 3/4" THICK HARDWOOD WALL 4"SUB WAITING G-119 1/4" WOOD REVEAL 11 1/4"5"BLOCKING, TYP. 1/2" TEMPERED GLAZING GLAZING HARDWOOD SILL AND WINDOW STOP 3/4" HARDWOOD SUB WAITING G-119 CL 9 1/2" 2 1/2"7"LIAISON G-114C BLOCKING, TYP. 1/2" TEMPERED GLAZING GLAZING HARDWOOD SILL AND WINDOW STOP 3/4" HARDWOOD 1/4" WOOD REVEAL 1/4" PLYWOOD FILLER6"SCHEDULED CEILING 4"1'-0" 1/4" WOOD REVEAL 1/2" PLYWOOD FILLER5"2 1/2"2 1/2"6" 3/4" 1/4" CAULK JOINT, TYP. SCHEDULED PARTITION SUB WAITING G-119 BLOCKING, TYP. 1/2" TEMPERED GLAZING GLAZING HARDWOOD SILL AND WINDOW STOP 3/4" HARDWOOD CL 2 1/2"2 1/2" 5"3/4"SUB WAITING G-119 7"BLOCKING, TYP. 1/2" TEMPERED GLAZING GLAZING HARDWOOD SILL AND WINDOW STOP 3/4" HARDWOOD 1/4" WOOD REVEAL 1/2" PLYWOOD FILLER HARDWOOD SILL AND WINDOW STOP 3/4" HARDWOOD 1/4" CAULK JOINT, TYP. SCHEDULED PARTITION CL 1'-4 1/2" 1/2" TEMPERED GLAZING EXISTING COLUMN Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION As indicated 8/15/2016 9:48:13 AMA9.60 185-01-00 8/15/16 LIAISON DESK DETAILS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER SCALE: SECTION DETAIL 1 1/2" = 1'-0" 10 LIAISON DESK CALLOUT SCALE: SECTION DETAIL 1 1/2" = 1'-0" 11 LIAISON DESK ELEVATION A SCALE: SECTION DETAIL 1 1/2" = 1'-0" 12 LIAISON DESK ELEVATION D SCALE: SECTION DETAIL 1 1/2" = 1'-0" 20 LIAISON DESK COUNTERTOP SECTION SCALE: SECTION DETAIL 3" = 1'-0" 23 LIAISON DESK COUNTERTOP DETAIL SCALE: SECTION DETAIL 3" = 1'-0" 31 LIAISON DESK WINDOW CORNER SCALE: SECTION DETAIL 3" = 1'-0" 22 LIAISON DESK IN BETWEEN WINDOWS SCALE: SECTION DETAIL 3" = 1'-0" 21 LIAISON DESK TO WALL SCALE: SECTION DETAIL 3" = 1'-0" 32 LIAISON DESK IN BETWEEN WINDOWS SCALE: SECTION DETAIL 3" = 1'-0" 30 LIAISON DESK WINDOW TO SIDE WALL Issuance Schedule Number Date Description 7 8 910 1112131415 16 18 19 20 21 22 23 25 26 27 28 SCOPE OF WORK RADIOLOGIST WORKROOM G-124 ULTRASOUND EQUIPMENT TASK CHAIR (EXISTING) STRETCHER STRETCHER BIOPSY TABLE SUCTION DEVICE STERILE SUPPLY CART RED BOX BLACK BOX GUEST CHAIR STEREO MONITOR STAND SOILED LINEN HAMPER SOILED LINEN HAMPER GUEST CHAIR SHARPS EXAM TABLE SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR REFRIGERATOR SHARPS SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR SHARPS GLOVES AQUISITION WORKSTATION WHEELCHAIR RED BOX WALL MOUNTED PADDLES SET UP TRAY SUCTION DEVICE C-ARMSOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR 5 MP MONITOR STAND FROM STEREOTATIC LARGE MAMMOGRAPHY G-120 AQUISITION WORKSTATION WHEELCHAIR SET UP TRAY SUCTION DEVICE C-ARM CLEAN WORK AREA G-126A INTERVIEW 2 G-117 PATIENT CHANGING ROOM 3 G-111C TASK CHAIR TASK CHAIRWALL MOUNTED PADDLES LARGE BIOPSY CHAIR PATIENT CHANGING ROOM 1 G-111D PATIENT CHANGING ROOM 2 G-111B STAFF TOILET G-130A TASK CHAIR EXAM 2 G-107 EXAM TABLE SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A TASK CHAIR BONE DENSITY G-113 GOWNED SUB-WAITING G-110 SOILED LINEN HAMPER TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR PRINTER FILM COPIER PRINTER TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR (EXISTING) BONE DENSITY TABLE BONE DENSITY WORKSTATION/CART WHEELCHAIR SCALE SOILED LINEN HAMPER GUEST CHAIR TASK CHAIR (EXISTING) STADIOMETER GLOVES PRINTER, SM SOAP PAPER TOILET PAPER SOAP PAPER TOILET PAPER PAPER SOAP SOILED LINEN BINTOILET PAPER TOILET PAPER COAT HOOKS CODE CART METRO RACK TRAY RACK 5 MP MONITOR STAND STEREO GENERATOR MIRCROWAVE KEURIG PURELL PURELL PURELL PURELL PURELL PURELL PURELLPURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL RED BOX SHARPS SHARPS TASK CHAIR (EXISTING) PURELL PURELL PURELL PURELL TASK CHAIR TASK CHAIR WITHOUT ARMS BACKERBOARD METRO RACK WOW TRASH STANDING WATER COOLER RECYCLE CONFIDENTIAL RECYCLE MOBILE PED MOBILE PED RADIOLOGIST WORKSTATION (EXISTING) RADIOLOGIST WORKSTATION (EXISTING) PHONE PHONE SIDE TABLE - SMALL TASK CHAIR WITHOUT ARMS STRETCHER ROUND TABLE WITH 4 CHAIRS LOUNGE CHAIR SCANNER SCANNER DESK DESK LOUNGE CHAIR PURELL INTERVIEW 1 G-118 ICE PAPER SOAP TRASH DEFIBRILLATOR SOAP PAPER PRINTER, SM TASK CHAIR STAFF BREAK ROOM G-123 CORRIDOR G-128 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B STRETCHER WAITING G-127 NURSE STATION G-126 ELECTRICAL CLOSET G-125 SUB WAITING G-119 LIAISON G-114C CORRIDOR G-119B SUB WAITING PATIENT TOILET G-119A MEN'S CHANGING & WAITING G-114 PATIENT TOILET G-109 CORRIDOR G-115D CORRIDOR G-115C STEREOTACTIC G-105 NAVIGATOR'S OFFICE G-116 ULTRASOUND G-121MAMMOGRAPHY G-122 EXAM 1 G-106 COPIER RECYCLE WASTEBASKET PURELL SIDE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR WHEELCHAIR TRASH SOAP LOUNGE CHAIR LOUNGE CHAIR WATER LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE SETTEE COFFEE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE MOBILE PED BLACK BOX MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED TASK CHAIR WASTEBASKET RECYCLE TRASH RECYCLE WASTEBASKET SOILED LINEN HAMPER TRASH PAPER SOAP PAPER TRASH SOAP TRASH PHONE PAPER SOAP COAT HOOKS VIEW BOX TRASH PAPER SOAP PHONE PURELL PAPER SOAP PHONE PHONE WASTEBASKET RECYCLE SHARPS SHARPS SHARPS PHONE PHONE GLOVES GLOVESGLOVES PHONE PURELL SOAPPAPER TRASH WASTEBASKET RECYCLE SOAP PAPER PAPER SOAP PAPERSOAP TRASH GLOVESGLOVES SOAP PAPER PAPER PAPER SOAP PHONE TRASH TRASH PHONE COMPUTER COMPUTER PHONE PHONESHARPS SHARPS PHONE COMPUTER COMPUTER SOAP MIRROR, TALL MIRROR, TALL MIRROR, TALL MIRROR, TALL PAPER WATER TRASH TRASH WASTEBASKET PHONE COMPUTER COMPUTER PHONE WASTEBASKET COMPUTER PHONE PHONE TRASH WASTEBASKET RECYCLE RECYCLE RECYCLE TRASH TRASH TRASH COAT HOOKS TRASH UC FRIDGE PHONE COMPUTER STABLERISE STABLERISE SCANNER SCANNER SCANNER CPU CPU CPU SCANNER SCANNER SCANNER CPU CPU CPU OFFICE G-108 CPU CPU Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION 1/4" = 1'-0"8/15/2016 9:48:14 AMA10.00 185-01-00 8/15/16 FF&E PLAN AND SCHEDULES COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER EQUIPMENT SCHEDULE MARK DESCRIPTION FURNISHED BY INSTALLED BY PLUMBING POWER T / D COMMENTS 5 MP MONITOR STAND 5 MP MONITOR STAND OWNER OWNER YES YES 5 MP MONITOR STAND FROM STEREOTATIC 5 MPG MONITOR STAND FROM STEREOTATIC OWNER OWNER YES YES ONLY 1 5MP MONITOR EXISTS, TO BE MOVED FROM STEREOTACTIC AQUISITION WORKSTATION SELENIA AWS 800 OWNER VENDOR YES YES BACKERBOARD BACKERBOARD OWNER OWNER BIOPSY TABLE MULTICARE PLATINUM OWNER VENDOR YES YES BLACK BOX 18 GALLON RCRA CONTAINER OWNER OWNER BONE DENSITY TABLE HOLOGIC DISCOVERY TABLE OWNER VENDOR YES YES BONE DENSITY WORKSTATION/CART HOLOGIC EXPLORER OWNER VENDOR YES YES C-ARM SELENIA DIMENSIONS OWNER VENDOR YES YES COAT HOOKS 4 COAT HOOKS OWNER OWNER CODE CART CODE CART OWNER OWNER YES COMPUTER HOSPITAL COMPUTER OWNER OWNER YES YES COPIER COPIER OWNER OWNER YES YES CPU CPU OWNER OWNER YES DEFIBRILLATOR DEFIBRILLATOR OWNER OWNER YES EXAM LIGHT, CEILING MOUNTED EXAM LIGHT OWNER OWNER YES REQUIRES JUNCTION BOX ABOVE CEILING EXAM TABLE EXAM TABLE OWNER OWNER FILM COPIER FILM COPIER OWNER OWNER YES YES GLOVES TRIPLE WIRE GLOVE BOX HOLDER OWNER OWNER ICE ICE MACHINE OWNER GENERAL CONTRACTOR YES YES KEURIG KEURIG OWNER OWNER YES LARGE BIOPSY CHAIR LARGE BIOPSY CHAIR OWNER OWNER METRO RACK 4' METRO WIRE SHELVING OWNER OWNER MIRCROWAVE MICROWAVE OWNER OWNER YES MIRROR, TALL FULL LENGTH OWNER OWNER PAPER PAPER TOWEL DISPENSER OWNER OWNER PHONE OWNER OWNER PRINTER PRINTER OWNER OWNER YES YES PRINTER, SM PRINTER SMALL OWNER OWNER YES YES PURELL HAND SANITIZER OWNER OWNER RECYCLE DESKSIDE RECYCLING CONTAINER OWNER OWNER RED BOX 18 GALLON PGII SHARPS CONTAINER OWNER OWNER REFRIGERATOR REFRIDGERTAOR OWNER OWNER YES SCALE SCALE OWNER OWNER SCANNER SCANNER OWNER OWNER YES SET UP TRAY SET UP TRAY OWNER OWNER SHARPS SHARP3, 3 GAL OWNER OWNER SOAP SOAP DISPENSER OWNER OWNER SOILED LINEN BIN SOILED LINEN BIN OWNER OWNER SOILED LINEN HAMPER SOILED LINEN HAMPER OWNER OWNER STABLERISE STABLERISE OWNER OWNER STADIOMETER STADIOMETER OWNER OWNER STANDING WATER COOLER STANDING WATER COOLER OWNER GENERAL CONTRACTOR YES YES STEREO GENERATOR STEREO GENERATOR OWNER VENDOR YES YES STEREO MONITOR STAND MULTI PLATINUM DSM CART OWNER VENDOR YES YES STERILE SUPPLY CART MULTICARE PLATNIUM ACCESSORY CART OWNER VENDOR STRETCHER STRETCHER OWNER OWNER SUCTION DEVICE SUCTION DEVICE OWNER VENDOR YES TOILET PAPER TOILET PAPER DISPENSER OWNER OWNER TRASH TRASH OWNER OWNER TRAY RACK METRO TRAY RACK STORAGE OWNER OWNER UC FRIDGE UNDERCOUNTER REFRIGERATOR OWNER OWNER YES ULTRASOUND EQUIPMENT PHILIPS IU22 ULTRASOUND OWNER VENDOR YES YES WALL MOUNTED PADDLES WALL MOUNTED PADDLES OWNER OWNER WASTEBASKET WASTEBASKET OWNER OWNER WATER WATER DISPENSER OWNER GENERAL CONTRACTOR YES YES WHEELCHAIR WHEELCHAIR OWNER OWNER WOW WORK STATION ON WHEELS OWNER OWNER YES YES FURNITURE SCHEDULE NEW / EXISTING MARK NEW COFFEE TABLE NEW DESK NEW GUEST CHAIR NEW LOUNGE CHAIR NEW MOBILE PED EXISTING RADIOLOGIST WORKSTATION (EXISTING) NEW ROUND TABLE WITH 4 CHAIRS NEW SETTEE NEW SIDE TABLE NEW SIDE TABLE - SMALL NEW TASK CHAIR EXISTING TASK CHAIR (EXISTING) NEW TASK CHAIR WITHOUT ARMS PHONE Issuance Schedule Number Date Description 1 7/8/2016 ADDENDUM 1 (VIF)1'-8" +/-(VIF) 2'-10" +/- NEW SAWCUT OPENING IN 12"+/- (VIF) CONC SLAB BEAM - SEE NOTE #6 NEW SAWCUT OPENING IN EXIST 6"+/- (VIF) CONC SLAB - PROTECT EXIST WALL TO REMAIN EXIST CONC FDN WALL (TYP) EXIST CONC COL (TYP) NEW SAWCUT OPENING IN EXIST 6"+/- (VIF) CONC SLAB (VIF) 2'-0" +/-(VIF)1'-6" +/-20 21 22 17 25 16 11121314 910 INFILL EXIST SLAB OPENING (VIF) - SEE "3/S2.00" INFILL EXIST SLAB OPENING (VIF) - SEE "3/S2.00" ..* * .... * * * * 3'-0" (MIN) CORES IN EXIST 12"+/- SLAB FOR MEP ALTERNATE #2 - SEE NOTE #5 EXIST CONC COL (VIF) EXIST 12"+/- CONC SLAB BEAM (VIF) (VIF) 1'-6 1/2"+/- EXIST SLAB PENETRATION (VIF) ALIGN EXIST 12"+/- CONC SLAB BEAM (VIF)1'-6" (MIN)2'-6" (MIN) 1'-6" (MIN) EXIST CONC BEAM LIGHT SUPPORT - COORD W/ARCH DWGS 1 S2.00 # NUMBER OR POUND & AND @ AT ARCH ARCHITECTURAL/ARCHITECT B/S BOTH SIDES BLDG BUILDING BM BEAM BOT BOTTOM C CHANNEL CANT CANTILEVER CFMF COLD-FORMED METAL FRAMING CJ CONTROL JOINT CL CENTER LINE CLR CLEAR COL COLUMN CONC CONCRETE CONST CONSTRUCTION CONT CONTINUOUS COORD COORDINATE DEMO DEMOLITION DIA DIAMETER DIM DIMENSION DWGS DRAWINGS EA EACH EF EACH FACE EL ELEVATION ELEC ELECTRICAL EOS EDGE OF SLAB EQ EQUAL EW EACH WAY EX EXISTING EXT EXTERIOR FDN FOUNDATION FF FINISHED FLOOR FT FOOT/FEET GR GRADE IN INCH(ES) INT INTERIOR STRUCTURAL ABBREVIATIONS K KIP(S) L ANGLE MAX MAXIMUM MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS NTS NOT TO SCALE O/C ON CENTER OF OUTSIDE FACE OH OPPOSITE HAND OPP OPPOSITE PAF POWDER ACTUATED FASTENER PEN PENETRATION PIA POST-INSTALLED ANCHOR PL PLATE QTY QUANTITY REINF REINFORCEMENT REQ'D REQUIRED SF SQUARE FOOT SIM SIMILAR SL SLOPE SOG SLAB ON GRADE SPEC SPECIFICATION STR STRUCTURAL T&B TOP AND BOTTOM TYP TYPICAL UON UNLESS OTHERWISE NOTED VERT VERTICAL VIF VERIFY IN FIELD W/ WITH W/O WITHOUT WWF WELDED WIRE FABRIC Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085 As indicated 8/15/2016 3:40:44 PMS1.00 185-01-00 8/15/16 GENERAL NOTES, GROUND FLOOR PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER 1. WITHIN (2)-WEEKS OF MOBILIZING TO SITE, AND PRIOR TO THE BEGINNING OF ANY FABRICATION, CONTRACTOR SHALL VERIFY ALL REQUIRED EXISTING CONDITIONS IN THE FIELD. NOTIFY ARCHITECT/ENGINEER IMMEDIATELY OF ANY DESCREPENCIES FOUND. ALLOW (2)-WEEKS FOR REVIEW BY DESIGN TEAM TO ADJUST DESIGN AS REQUIRED. 2. CONTRACTOR TO COORDINATE SIZE AND LOCATION OF ALL OPENINGS WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS AND MEP CONTRACTORS. 3. CONTRACTOR PERFORMING STRUCTURAL WORK SHALL BE RESPONSIBLE FOR ALL SHORING OF EXISTING CONSTRUCTION REQUIRED TO SAFELY COMPLETE WORK. 4. IF EXISTING SLAB OPENINGS NOT SHOWN ON THESE DOCUMENTS ARE FIELD VERIFIED TO BE PRESENT IN THE VISCINITY OF PROPOSED NEW SLAB OPENINGS, CONTACT ENGINEER IMMEDIATELY FOR REVIEW OF AS-BUILT CONDITIONS. 5. CONTRACTOR SHALL FIELD VERIFY LOCATION OF EXISTING TOP AND BOTTOM SLAB REINFORCING USING NON-DESTRUCTIVE TEST METHODS. NEW CORES SHALL NOT CUT THROUGH ANY TOP OR BOTTOM EXISTING SLAB BEAM REINFORCING. CORES SHALL BE LOCATED A MINIMUM OF 12" FROM THE FACE OF THE EXISTING CONCRETE COLUMN. PROVIDE 3" CLEAR MINIMUM BETWEEN ADJACENT CORES. COORDINATE SIZE AND LOCATION WITH MEP DRAWINGS AND MEP CONTRACTORS. 6. CONTRACTOR SHALL FIELD VERIFY LOCATION OF EXISTING BOTTOM CONCRETE SLAB BEAM REINFORCING USING NON-DESTRUCTIVE TEST METHODS. NEW OPENING SHALL ONLY INTERUPT (1)-EXISTING REINFORCING BAR MAXIMUM. EXISTING STRUCTURAL DRAWINGS INDICATE SLAB BEAM IS REINFORCED WITH (9)-CONTINUOUS BOTTOM BARS. NOTIFY ENGINEER IMMEDIATE IF ANY DISCREPENCIES ARE NOTED. 7. INDICATES COORDINATE FINAL DIMENSION WITH MEP DRAWINGS AND MEP CONTRACTORS. 1/4" = 1'-0" GROUND FLOOR PLAN STRUCTURAL GENERAL NOTES GENERAL 1. SEE ARCHITECTURAL, MECHANICAL, ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS AND DETAILS. 2. STRUCTURAL CONDITIONS WHERE SECTIONS OR DETAILS ARE CUT SHALL ALSO APPLY TO COMPARABLE SIMILAR LOCATIONS ELSEWHERE ON THE PLANS REGARDLESS IF THE SECTION MARK IS NOT INDICATED. DETAILS SHOWN APPLY TO ALL SIMILAR CONDITIONS UNLESS OTHERWISE NOTED. DO NOT SCALE DRAWINGS. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, ELEVATIONS, QUANTITIES, ETC., IN THE FIELD PRIOR TO BEGINNING OF ANY NEW CONSTRUCTION. NOTIFY ENGINEER/ARCHITECT OF ANY DISCREPANCIES FOUND IMMEDIATELY. 4. CONTRACTOR SHALL VERIFY AND COORDINATE THE DIMENSIONS, LAYOUT AND DETAILS OF ALL OPENINGS, PENETRATIONS, ETC. CONTRACTOR SHALL REVIEW ALL OF THE CONTRACT DOCUMENTS AND CONSULT WITH THE SUBCONTRACTORS AND SUPPLIERS TO OBTAIN THE REQUIRED INFORMATION. OPENINGS, PENETRATIONS, ETC. THAT VARY FROM OR HAVE NOT BEEN INDICATED ON THE STRUCTURAL DOCUMENTS, SHALL BE INSTALLED AT NO ADDITIONAL COST, ONLY AFTER APPROVAL BY THE STRUCTURAL ENGINEER HAS BEEN OBTAINED.CODES 1. ALLOWABLE UNIT STRESSES AND DESIGN CRITERIA IN ACCORDANCE WITH THE FOLLOWING - A) 'THE 2009 INTERNATIONAL BUILDING CODE' WITH THE '2010 STATE OF MASSACHUSETTS AMENDMENT'. B) 'MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES', ASCE/SEI 7-05. C) 'SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS-', AISC 360-05 D) 'BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE', ACI 318-08. DESIGN CRITERIA 1. WELDED WIRE FABRIC ASTM A 185 Fy=60 KSI 2. REINFORCING STEEL ASTM A 615 GRADE 60, Fy=60 KSI 3. CONCRETE FOR SLAB INFILLS f'c=4,000 PSI (UNLESS OTHERWISE NOTED) CONCRETE 21. TEST SLUMP IN ACCORDANCE WITH ASTM C 143. ONE TEST SHALL BE PERFORMED FOR EACH COMPOSITE SAMPLE, BUT NOT LESS THAN ONE TEST FOR EACH DAY'S POUR OF EACH CONCRETE MIXTURE. 22. TEST AIR CONTENT IN ACCORDANCE WITH ASTM C 231. ONE TEST SHALL BE PERFORMED FOR EACH COMPOSITE SAMPLE, BUT NOT LESS THAN ONE TEST FOR EACH DAY'S POUR OF EACH CONCRETE MIXTURE. 23. TEST CONCRETE TEMPERATURE IN ACCORDANCE WITH ASTM C 1064. ONE TEST SHALL BE PERFORMED FOR EACH COMPOSITE SAMPLE, AND ONE TEST SHALL BE PERFORMED HOURLY WHEN AIR TEMPERATURE IS 40 DEGREES F AND BELOW AND WHEN 80 DEGREES F AND ABOVE. 24. CONCRETE COMPRESSIVE TEST SPECIMENS SHALL BE TAKEN IN ACCORDANCE WITH ASTM C 31. - CAST AND LABORATORY CURE ONE SET OF FOUR STANDARD CYLINDER SPECIMENS FOR EACH COMPOSITE SAMPLE. 25. COMPRESSIVE-STRENGTH TESTS: ASTM C 39; TEST ONE SPECIMEN AT 7 DAYS AND TWO SPECIMENS AT 28 DAYS, AND ONE SPECIMEN RETAINED IN RESERVE FOR THE LATER TESTING IF REQUIRED. - STRENGTH OF EACH CONCRETE MIXTURE WILL BE CONSIDERED SATISFACTORY IF EVERY AVERAGE OF ANY THREE CONSECUTIVE COMPRESSIVE-STRENGTH TESTS EQUALS OR EXCEEDS SPECIFIED COMPRESSIVE STRENGTH AND NO COMPRESSIVE-STRENGTH TEST VALUE FALLS BELOW SPECIFIED COMPRESSIVE STRENGTH BY MORE THAN 500 PSI. - TEST RESULTS SHALL BE REPORTED IN WRITING TO THE STRUCTURAL ENGINEER, CONTRACTORS, ARCHITECT, AND CONCRETE MANUFACTURER WITHIN 24 HOURS OF TESTING. - ADDITIONAL TESTING AND INSPECTING, AT THE CONTRACTOR'S EXPENSE, WILL BE PERFORMED AT THE ENGINEER'S DIRECTION IF WORK IS FOUND TO BE NOT IN COMFORMANCE WITH PROJECT REQUIREMENTS. CONCRETE 1. ALL CONCRETE REINFORCING SHALL BE DETAILED, FABRICATED, LABELED, SUPPORTED AND SPACED IN FORMS AND SECURED IN PLACE IN ACCORDANCE WITH ACI PROCEDURES AND THE REQUIREMENTS OF THE CODES IN THE PREVIOUSLY OUTLINED "CODES" SECTION AND THE 'MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES', ACI-315. 2. CHECKED SHOP DRAWINGS SHOWING REINFORCING DETAILS, INCLUDING CONSTRUCTION JOINTS, OPENINGS, REINFORCING SIZES, SPACING AND PLACEMENT SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION. UNCHECKED SHOP DRAWINGS WILL BE REJECTED WITHOUT REVIEW. 3. ALL WELDED WIRE FABRIC SHALL BE LAPPED TWO (2)-FULL MESH PANELS AND TIED SECURELY. 4. NO CALCIUM CHLORIDE SHALL BE USED IN ANY CONCRETE. 5. SUBMIT THE FOLLOWING: - PRODUCT DATA FOR EACH PRODUCT INDICATED INCLUDING REINFORCEMENT, ADMIXTURES, AND OTHERS IF REQUESTED BY THE ENGINEER. - CONCRETE DESIGN MIXTURES FOR EACH CONCRETE MIXTURE USED. - LABORATORY TEST REPORTS FOR CONCRETE MATERIALS AND MIX DESIGN TESTS. - A WRITTEN DESCRIPTION OF CURING PROCEDURES FOR REVIEW AND APPROVAL A MINIMUM OF 15 DAYS PRIOR TO START OF WORK. DESCRIPTION TO INCLUDE CURING METHODS AND DURATION OF CURING. - STEEL REINFORCEMENT SHOP DRAWINGS: DRAWINGS THAT CLEARLY SHOW LOCATION, SPLICING, COVER, SIZES AND SPACING OF ALL REINFORCING AND WIRE FABRIC. SCHEDULES AND DIAGRAMS SHALL INDICATE BENDS, SIZES, LENGTHS OF REINFORCING MEMBERS AND SPLICE LENGTHS. INCLUDE ANY SUPPLEMENT REINFORCEMENT REQUIRED INCLUDING BUT NOT LIMITED TO SLAB EDGE REINFORCING, CORNER BARS, RE-ENTRY BARS AND SLAB OPENINGS. - MATERIAL CERTIFICATES FOR CEMENTITIOUS MATERIALS, ADMIXTURES, STEEL REINFORCMENT AND ACCESSORIES, AND MOISTURE VAPOR REDUCING ADMIXTURE (MVRA) - NO REINFORCING SHALL BE CUT, FABRICATED, SHIPPED TO THE JOB SITE OR PLACED BEFORE SHOP DRAWINGS HAVE BEEN APPROVED BY THE ENGINEER OF RECORD. ONLY SHOP DRAWINGS BEARING THE APPROPRIATE ENGINEER'S STAMP MARKED "FURNISH AS SUBMITTED" OR "FURNISHED AS CORRECTED" OR "FURNISHED AS CORRECTED AND RESUBMIT FOR RECORD" SHALL BE USED IN FIELD. 6. STRUCTURAL SLABS AND SLABS ON DECK SHALL NOT CONTAIN ANY ELECTRICAL CONDUITS OR PIPING. 7. CONCRETE FOR SLAB INFILLS TO BE NORMAL WEIGHT CONCRETE WITH A 4,000PSI 28-DAY MINIMUM COMPRESSIVE STENGTH, MINIMUM CEMENT CONTENT OF 6 SACKS PER CUBIC YARD, WATER-CEMENT RATIO 0.45 MAXIMUM (WATER CONTENT SHALL INCLUDE SURFACE WATER IN AGGREGATES), MAXIMUM 3/4" AGGREGATE, FOUR PLUS OR MINUS 1 INCH SLUMP. NO ADDITIONAL AIR ENTRAINMENT IS TO BE PROVIDED AT INTERIOR SLABS. PROVIDE MOISTURE VAPOR REDUCING ADMIXTURE (MVRA) IN ALL INTERIOR SLABS. IF MIX IS TO BE PUMPED, ALLOWED SLUMP CAN BE INCREASED TO SIX PLUS OR MINUS ONE INCH. SUBMIT SEPARATE MIX DESIGNS,INCLUDING ALL BACKUP DATA, FOR EACH PUMP MIX FOR APPROVAL BY THE ENGINEER 8. ADJUSTMENTS TO CONCRETE MIXES: FIELD WATER IS NOT TO BE ADDED. MIX DESIGN ADJUSTMENTS MAY BE REQUESTED BY THE CONTRACTOR WHEN CHARACTERISTICS OF MATERIALS, JOB CONDITIONS, TEST RESULTS OR OTHER CIRCUMSTANCES WARRANT, AS ACCEPTED BY THE ENGINEER. LABORATORY TEST DATA FOR REVISED MIX DESIGN AND STRENGTH RESULTS MUST BE SUBMITTED TO AND ACCEPTED BY THE ENGINEER BEFORE USING IN WORK. 9. DO NOT AIR ENTRAIN CONCRETE AT INTERIOR SLABS. DO NOT ALLOW ENTRAPPED AIR CONTENT TO EXCEED 3 PERCENT. 10. USE FLY ASH, POZZOLAN, GROUND GRANULATED BLAST-FURNACE SLAG AND SILICA FUME AS NEEDED TO REDUCE THE TOTAL AMOUNT OF PORTLAND CEMENT WHICH WOULD OTHERWISE BE USED, BY NOT LESS THAN 40 PERCENT. 11. USE ADMIXTURES ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. ADMIXTURES ARE NOT TO BE ADDED IN THE FIELD. FIELD WATER IS NOT BE TO ADDED. 12. CHEMICAL ADMIXTURES: PROVIDE ADMIXTURES CERTIFIED BY MANUFACTURER TO BE COMPATIBLE WITH OTHER ADMIXTURES AND THAT WILL NOT CONTRIBUTE WATER-SOLUBLE CHLORIDE IONS EXCEEDING 0.15 PERCENT BY MASS OF CEMENT MATERIAL. DO NOT USE CALCIUM CHLORIDE OR ADMIXTURES CONTAINING CALCIUM CHLORIDE. 13. ADMIXTURES SHALL CONFORM TO THE FOLLOWING: WATER REDUCING ADMIXTURE: ASTM C 494/C 494M, TYPE A, RETARDING ADMIXTURE: ASTM C 494/C 494M, TYPE B, WATER-REDUCING AND RETARDING ADMIXTURE: ASTM C 494/C 494M, TYPE D, MOISTURE VAPOR REDUCTION ADMIXTURE (MVRA): ASTM C 494/C494M, TYPE S 14. CONCRETE MOISTURE VAPOR REDUCTION ADMIXTURE (MVRA): CONCRETE MOISTURE VAPOR REDUCTION ADMIXTURE, PROVIDED FOR ALL INTERIOR SLABS SHALL BE A NON-TOXIC, LIQUID ADMIXTURE THAT IS SPECIFICALLY DESIGNED TO HAVE A NATURAL CHEMICAL REACTION WITH PRE-EXISTING ELEMENTS INSIDE THE CONCRETE ELEMENTS TO ELIMINATE THE ROUTE OF MOISTURE VAPOR EMISSION THROUGH THE SLAB BY RESTRICTING THE INTEGRAL CAPILLARY SYSTEM. THE CHEMICAL REACTION FORMS A PERMANENT BARRIER (CAPILLARY BREAK) THAT IS INTEGRAL TO THE CONCRETE, INSOLUBLE AND IRREMOVABLE. - BASIS-OF-DESIGN PRODUCT: "BARRIER ONE HIGH PERFORMANCE CONCRETE ADMIXTURE" MANUFACTURED BY BARRIER ONE, INC.; 522 S. HUNT CLUB BLVD., #303, APOPKA, FL 32703. CONTACT MANUFACTURER'S REPRESENTATIVE: P: 877.224.5850; F: 866.594.3490 OR EMAIL AT INFO@BARRIERONE.COM. - PROVIDE THE ABOVE NAMED PRODUCT, OR UPON APPROVAL OF THE ARCHITECT / STRUCTURAL ENGINEER, PROVIDE A PRODUCT THAT MEETS OR EXCEEDS THE FOLLOWING PROJECT SPECIFIC PERFORMANCE REQUIREMENTS AT THE EXPENSE OF THE CONCRETE MOISTURE VAPOR REDUCTION ADMIXTURE MANUFACTURER. PERFORMANCE REQUIREMENTS INCLUDE BUT ARE NOT LIMITED TO: INDEPENDENT PROCUREMENT OF ONE CYLINDER PER DAY OF PLACEMENT OF CONCRETE CONTAINING MVRA; DO NOT PROCEED WITHOUT MVRA REPRESENTATIVE BEING PRESENT, INDEPENDENT TESTING OF ALL CYLINDERS FOR HYDRAULIC CONDUCTIVITY PER ASTM D5084 AND ASSESSING EACH CYLINDER FOR MAXIMUM FLOW OF 6.0 E-08 CM/SEC. SHOULD ANY CYLINDER EXCEED MAXIMUM FLOW, PROCURE A CORE FROM THAT DAYS PLACEMENT AND TEST CORE FOR HYDROLIC CONDUCTIVITY PER ASTM D5084. SHOULD ANY CORE EXCEED THE MAXIMUM FLOW, PROVIDE A TOPICAL MOISTURE MITIGATION SYSTEM FOR ALL AREAS NOT MEETING THE STATED LIMIT. MOISTURE MIGITATION SYSTEM TO INCLUDE ALL LABOR, MATERIAL AND WARRANTY THAT MEETS OR EXCEEDS THE TERMS OF THE CONCRETE MOISTURE VAPOR REDUCTION ADMIXTURE MANUFACTURER'S WARRANTY. ADDITIONALLY MVRA MANUFACTURER'S WARRANTY SHALL INCLUDE: A TERM OF THE LIFE OF THE CONCRETE, REPAIR AND/OR REMOVAL OF FAILED FLOORING, PLACEMENT OF A TOPICAL MOISTURE REMEDIATION SYSTEM AND REPLACEMENT OF FLOORING MATERIALS LIKE THE ORIGINAL INSTALLED TO INCLUDE MATERIAL AND LABOR. MVRA MANUFACTURER SHALL ALSO PROVIDE AN ADHESION WARRANTY TO MATCH THE TERM OF THE ADHESIVE MANUFACTURER'S WARRANTY IN ACCORDANCE WITH THE MVRA MANUFACTURER'S REQUIREMENTS FOR CONVEYANCE OF SUCH. 15. COLD WEATHER PLACEMENT: COMPLY WITH ALL REQUIREMENTS OF ACI306.1. PROTECT CONCRETE FROM PHYSICAL DAMAGE OR REDUCED STRENGTH THAT COULD BE CAUSED BY FROST, FREEZING ACTIONS, OR LOW TEMPERATURES. WHEN THE AVERAGE HIGH AND LOW TEMPERATURE IS EXPECTED TO FALL BELOW 40 DEGREES F FOR THREE SUCCESSIVE DAYS, MAINTAIN DELIVERED CONCRETE MIXTURE WITHIN THE TEMPERATURE RANGE REQUIRED BY ACI 301. 16. HOT WEATHER PLACEMENT: PLACE CONCRETE ACCORDING TO RECOMMENDATIONS IN ACI 305R WHEN HOT WEATHER CONDITIONS EXIST. HOT WEATHER IS ANY COMBINATION OF HIGH AMBIENT TEMPERATURE, HIGH CONCRETE TEMPERATURE, LOW RELATIVE HUMIDITY, WIND SPEED, OR SOLAR RADIATION THAT WILL IMPACT THE QUALITY OF FRESHLY MIXED OR HARDENED CONCRETE. COOL INGREDIENTS BEFORE MIXING TO MAINTAIN CONCRETE TEMPERATURE BELOW 90 DEGREES F AT TIME OF PLACEMENT. CHILLED MIXING WATER OR CHOPPED ICE MAY BE USED TO CONTROL TEMPERATURE, PROVIDED WATER EQUIVALENT OF ICE IS CALCULATED TOTAL AMOUNT OF MXIING WATER. 17. OWNER WILL ENGAGE A SPECIAL INSPECTOR AND QUALIFIED TESTING AND INSPECTING AGENCY TO PERFORM FIELD TESTS AND INSPECTIONS AND PREPARE TEST REPORTS. 18. CONCRETE TESTS: TESTING OF COMPOSITE SAMPLES OF FRESH CONCRETE OBTAINED ACCORDING TO ASTM C172 SHALL BE PERFORMED ACCORDING TO THE FOLLOWING REQUIREMENTS. 19. OBTAIN ONE COMPOSITE SAMPLE FOR EACH DAY'S POUR OF CONCRETE, PLUS ONE SET FOR EACH ADDITIONAL 50 CUBIC YARDS OR FRACTION THEREOF. CONTRACTOR SHALL NOTIFY THE OWNER'S INSPECTION AGENCY 24 HOURS PRIOR TO PLACING CONCRETE TO INSPECT SECURED REINFORCING. NO CONCRETE SHALL BE PLACED UNTIL REINFORCING HAS BEEN INSPECTED BY THE OWNER'S TESTING AND INSPECTION AGENCY. 20. WHEN CONCRETE IS PUMPED, TEST CYLINDERS SHALL BE MADE FROM CONCRETE TAKEN AT DISCHARGE END OF THE PUMPING TRAIN. POST INSTALLED ANCHORS (PIA) 1. POST INSTALLED ADHESIVE ANCHORS SHALL BE INSTALLED USING HILTI RE-500SD OR APPROVED EQUAL. 2. ALL POST INSTALLED ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 3. TESTING AGENCY SHALL RANDOMLY REVIEW ANCHORING INSTALLATION TO VERIFY CONFORMANCE WITH CONTRACT DOCUMENTS AND MANUFACTURER'S INSTALLATION REQUIREMENTS. INITIAL INSPECTIONS SHALL OCCUR AT FIRST APPLICATION FOR EACH TYPE OF ANCHOR TO VERIFY CONFORMANCE. THE NUMBER OF POST INSTALLED ANCHOR INSTALLATIONS TO BE WITNESSED BY THE OWNER'S TESTING AGENCY SHALL MEET THE FOLLOWING CRITERIA: 3a. A MINIMUM OF 25% OF ADHESIVE ANCHOR INSTALLATIONS PER SUB CONTRACTOR SHALL BE WITNESSED. THE PERCENTAGE WITNESSED MAY BE MODIFIED BY THE STRUCTURAL ENGINEER OF RECORD, DEPENDING UPON INITIAL RESULTS. 4. LOAD TESTING OF POST INSTALLED ANCHORS MAY BE REQUESTED BY THE STRUCTURAL ENGINEER OF RECORD FOLLOWING THE RESULT OF THE TESTING AGENCY'S INSTALLATION REPORTS. LOAD TESTING SHALL BE PERFORMED AT NO ADDITIONAL COST TO THE OWNER. * STRUCTURAL STEEL 1. ALL STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE REFERENCED EDITION OF THE AISC 'SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS'. 2. ALL WELDING ELECTRODES SHALL BE E70XX UNLESS OTHERWISE NOTED. 3. ALL BOLTS, NUTS AND WASHERS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A 325 OR ASTM A 490. 4. ALL WELDING SHALL BE BY CERTIFIED WELDERS AND SHALL CONFORM TO AWS 'CODE OF ARC AND GAS WELDING IN BUILDING CONSTRUCTION', LATEST EDITION. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ERECTION PROCEDURES AND SEQUENCES INCLUDING TEMPORARY BRACING AND SHORING. 6. THERE SHALL BE NO FIELD CUTTING OF STRUCTURAL STEEL MEMBERS WITHOUT THE PRIOR APPROVAL OF THE ENGINEER. 7. ANY ADDITIONAL STEEL REQUIRED BY THE CONTRACTOR FOR ERECTION PURPOSES AND SITE ACCESS OR MATERIALS FOR STOCKPILING STEEL SHALL BE PROVIDED AT NO COST TO THE OWNER. ALL SUCH ADDITIONAL STEEL SHALL BE REMOVED BY THE CONTRACTOR UNLESS APPROVED BY THE OWNER IN WRITING. 8. ALL FIELD WELDS SHALL BE SCRAPED AND CLEANED FREE OF SLAG BY WELDER/ERECTOR TO ENABLE VISUAL WELD INSPECTION. STRUCTURAL DRAWING LIST S1.00 GENERAL NOTES, GROUND FLOOR PLAN S2.00 FRAMING DETAILS Grand total: 2 Issuance Schedule Number Date Description 1/2" STEEL STIFFENER PLATE - SEE "A/S2.00" EXIST CONC SLAB (VIF) LIGHT ASSEMBLY BY LIGHT CONTRACTOR (4)-1/2" DIA A36 THREADED RODS FOR CEILING - SEE ARCH DWGS POWER BOX BY LIGHT CONTRACTOR NOTES: 1. INDICATES COORDINATE FINAL DIMENSION WITH EQUIPMENT SUPPLIER/CONTRACTOR AND ARCHITECT. 2. CONTRACTORS OPTION TO USE 3/4" DIA F1852 SLIP CRITICAL BOLTS IN LIEU OF FIELD WELDING. 3. CONTRACTOR TO FIELD LOCATE EXISTING SLAB REINFORCING USING NON-DESTRUCTIVE TESTING METHODS. ADJUST LOCATION OF PIA AS REQUIRED TO AVOID DAMAGING EXISTING SLAB REINFORCING. 4. FOR ADDITIONAL INFORMATION AND REQUIREMENTS, SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS AND LIGHT SUPPLIER/CONTRACTOR DOCUMENTS.6" +/-*.(VIF).* * (4)-L3x3x5/16 KICKERS PROVIDE DOUBLE NUTS TIGHTEN NUTS & DAMAGE THREADS 1 1 CUT VERT LEG & BEND HORIZ LEG @ STIFFENER PLATE TO ALLOW FOR CONN @ THREADED ROD (TYP)(VIF)6" +/-L4x4x5/16 x 0'-6" LONG @ EA KICKER 1/4 2 TYP SEE NOTE #2 5/8" DIA HILTI KWIK BOLT 3 EMBEDDED 4" INTO EXIST CONC SLAB (TYP) SEE NOTE #3 5/8" DIA HILTI KWIK BOLT 3 EMBEDDED 4" INTO EXIST CONC SLAB (TYP) - SEE NOTE #3 L4x4x5/16 & L4x3x5/16 (LLV) x 0'- 6" LONG @ EA HANGER. PROVIDE 1 1/2" VERT SLOTTED HOLE IN L4x3 FOR FIELD ADJ 3/4" DIA F1852 SLIP CRITICAL BOLT (TYP) * 9"9"5"x5" OPNG NOTES: 1. COORDINATE FINAL PLATE DIMENSIONS AND HOLE LOCATIONS WITH LIGHT CONTRACTOR.6.313".6.313". HOLE FOR THREADED ROD (TYP) PROVIDE RADIUSED CORNERS (TYP) EXISTING CONC SLAB (VIF) SAW CUT OPENING FROM CORE DRILLED CORNER HOLES AS REQ'D. NO OVER CUTS ALLOWED (TYP) CORE DRILL ALL NEW OPENING CORNERS W/3" (MIN) DIA HOLES (TYP) NEW OPENING - SEE PLAN & COORD W/MEP & ARCH DWGS NOTES: 1. COORDINATE SIZE AND LOCATION OF OPENINGS WITH MEP DRAWINGS AND MEP CONTRACTORS. 2. CONTRACTOR TO PROTECT ALL EXISTING CONSTRUCTION TO REMAIN. EXIST CONC SLAB (VIF)(VIF)6" +/-FORM AND SUPPORT INFILL AS REQ'D. INFILL TO BE SUPPORTED UNTIL CONCRETE ATTAINS FULL DESIGN STRENGTH. (VIF) EXIST SLAB OPENING NOTES: 1. CONTRACTOR TO FIELD VERIFY SIZE OF EXISTING OPENINGS IN THE FIELD PRIOR TO BEGINNING ANY FABRICATION. 2. IF SIZE OF OPENING TO BE INFILLED EXCEEDS 36" IN ANY DIMENSION, NOTIFY ENGINEER IMMEDIATELY TO REVIEW CONDITION. NEW CONC INFILL REINFORCED W/(2)-LAYERS OF W2.9xW2.9-6x6 WWF (TOP & BOT) #5 REBAR PIA x 1'-8" LONG @ 6" O/C W/STD 90 DEGREE HOOK EMBEDDED 6" INTO EXIST CONC SLAB (TYP)CLR3/4"EQEQCLR3/4"Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. As indicated 8/15/2016 3:40:44 PMS2.00 185-01-00 8/15/16 FRAMING DETAILS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER 1 1/2" = 1'-0"S2.00 1 LIGHT SUPPORT DETAIL 1 1/2" = 1'-0"S2.00 A STIFFENER PLATE DETAIL NOT TO SCALES2.00 2 TYPICAL NEW OPENING IN EXISTING SLAB 3/4" = 1'-0"S2.00 3 TYPICAL EXISTING SLAB PENETRATION INFILL DETAIL Issuance Schedule Number Date Description A GENERAL SERVICE COMPRESSED AIR a 48" ABOVE FINISHED FLOOR A/AMP AMPERE AC AIR COMPRESSOR AC ALTERNATING CURRENT ACD AUTOMATIC COOLING CONDENSATE PUMP ACF AIRFLOW CENTRIFUGAL FAN ACU AIR CONDITIONING UNIT(S) AD ACCESS DOOR AD AREA DRAIN AF ARC FAULT AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHU AIR HANDLING UNIT AIC AMPS INTERRUPTING CURRENT AMB AMBIENT ANN ANNUNCIATOR ANSI AMERICAN NATIONAL STANDARDS INSTITUTE APD AIR PRESSURE DROP APPROX APPROXIMATE ARV AXIAL ROOF VENTILATOR AS AIR SEPARATOR ATC AUTOMATIC TEMPERATURE CONTROL ATS AUTOMATIC TRANSFER SWITCH AV ACID VENT (CHEMICAL) AVG AVERAGE AVTR ACID VENT THRU ROOF AW ACID WASTE AWG AMERICAN WIRE GAUGE AWT AVERAGE WATER TEMPERATURE b 42" ABOVE FINISHED FLOOR BCT BONDING CONDUCTOR FOR TELECOMMUNICATIONS BDD BACK DRAFT DAMPER BFW BOILER FEED WATER BHP BRAKE HORSEPOWER BICF BACKWARD INCLINED CENTRIFUGAL FAN BICSI BUILDING INDUSTRY CONSULTING SERVICE INTERNATIONAL BNC BAYONET NEIL-CONCELMAN BSMT BASEMENT BTU BRITISH THERMAL UNITS BTUH BRITISH THERMAL UNITS/HOUR c CEILING MOUNTED C CONDUIT(S) C/B CIRCUIT BREAKER CAT CATEGORY ETHERNET CABLE CATV COMMUNITY ANTENNA TELEVISION CC COOLING COIL CCTV CLOSED CIRCUIT TELEVISION CER/CEG CEILING EXHAUST REG./GRILLE CFM CUBIC FEET PER MINUTE CFP CHEMICAL FEED PUMPS CHP CONSOLE HEAT PUMP CHWR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY CI CAST IRON CKT CIRCUIT CLG CEILING CLGWTR COOLING WATER CLPS CLEAN LOW PRESSURE STEAM CMPS CLEAN MEDIUM PRESSURE STEAM CMV CEILING MOUNTED VENTILATOR CO CLEANOUT CO2 CARBON DIOXIDE COAX COAXIAL CABLING COMP COMPRESSOR COND CONDENSER CONV CONVECTOR COP COPPER CABLING CP CONDENSATE PUMP CPU CENTRAL PROCESSING UNIT CRU COMPUTER ROOM UNIT CRV CENTRIFUGAL ROOF VENTILATOR CT CABLE TRAY CT COOLING TOWER CT CURRENT TRANSFORMER CU CONDENSING UNIT CU FT CUBIC FEET CUH CABINET UNIT HEATER CV COEFFICIENT, VALVE FLOW CV CONSTANT VOLUME CVP CEILING VIDEO PRESENTATION CW COLD WATER CWR CONDENSER WATER RETURN CWS CONDENSER WATER SUPPLY CWV CENTRIFUGAL WALL VENTILATOR D DATA D DEPTH DA DISTRIBUTOR A DB DISTRIBUTOR B DB DRY BULB TEMPERATURE dB DECIBEL DC DIRECT CURRENT DC DISTRIBUTOR C DCV DOUBLE CHECK VALVE DE DEIONIZED PROCESS WATER DEG or ° DEGREE DEMARC DEMARCATION DET DOMESTIC EXPANSION TANK (PLUMBING) DI DISTILLED WATER DIA or Ø DIAMETER DN DOWN DP DIFFERENTIAL PRESSURE DSA DUCT SOUND ATTENUATORS DWBP DOMESTIC WATER BOOSTER PUMP DWG DRAWING DX DIRECT EXPANSION EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE EBR ELECTRIC BASEBOARD RADIATION EDR EQUIVALENT DIRECT RADIATION EF ENTRANCE FACILITY EF EXHAUST FAN EFF EFFICIENCY EHC ELECTRICAL HEATING CABLES EIA ELECTRONICS INDUSTRIES ALLIANCE ELEC ELECTRICAL ELEV ELEVATOR EM EMERGENCY EM/NL EMERGENCY/NIGHT LIGHT WALK-THRU EMI ELECTROMAGNETIC INTERFERENCE EMT ELECTRICAL METALLIC TUBING ER EQUIPMENT ROOM ESP EXTERNAL STATIC PRESSURE ET EXPANSION TANK (HVAC) ETP ELECTRIC TRAP PRIMER EUH ELECTRIC UNIT HEATER EVAP EVAPORATOR EWB ENTERING WET BULB TEMPERATURE EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EWT ENTERING WATER TEMPERATURE EXH EXHAUST EXP EXPANSION F FAHRENHEIT FA FIRE ALARM FC FOOT CANDLE FCCF FORWARD CURVE CENTRIFUGAL FAN FCU FAN COIL UNIT FD FIRE DAMPER FD FLOOR DRAIN FD/SB FIRE DAMPER WITH INTEGRAL SECURITY BARS FDC FIRE DEPARTMENT CONNECTION FDV FIRE DEPARTMENT VALVE FHC FIRE HOSE CABINET FM FLOW METER FMC FLEXIBLE METALLIC TUBING FOB FLAT ON BOTTOM FOF FUEL OIL FILL FOR FUEL OIL RETURN FOS FUEL OIL SUPPLY FOT FLAT ON TOP FOV FUEL OIL VENT FP FIRE PUMP FPM FEET PER MINUTE FPS FEET PER SECOND FS FLOOR SINK FT FOOT OR FEET FVC FIRE VALVE CABINET G GAS GA GAUGE GAL GALLONS GCC GRAVITY COOLING CONDENSATE GE GROUNDING EQUALIZER GEC GROUNDING ELECTRODE CONDUCTOR GF GROUND FAULT GND GROUND GPH GALLONS PER HOUR GPM GALLONS PER MINUTE GR GRAINS GRU GREASE RECOVERY UNIT GW GREASE WASTE GWA GREASE WASTE ABOVE GRADE GWB GREASE WASTE BURIED GWH GAS WATER HEATER H HEIGHT H/C HEATING/COOLING HC HEATING COIL HC HORIZONTAL CROSS-CONNECT HD HEAD HDCP HANDICAP HP HORSEPOWER HPC HIGH PRESSURE CONDENSATE HPG HIGH PRESSURE GAS HPS HIGH PRESSURE SODIUM HPS HIGH PRESSURE STEAM HR HOUR(S) HT HEAT HTHW HIGH TEMPERATURE HOT WATER HTHWR HIGH TEMPERATURE HOT WATER RETURN HTHWS HIGH TEMPERATURE HOT WATER SUPPLY HTR HEATER HUM HUMIDIFIER HV HEATING/VENTILATION UNIT HVAC HEATING, VENTILATION AND AIR CONDITIONING HW HOT WATER HWR HOT WATER RETURN HWRP HOT WATER RETURN PUMP HWRR HOT WATER REVERSE RETURN HWS HOT WATER SUPPLY HX HEAT EXCHANGER HZ FREQUENCY (CYCLES PER SECOND) IC INTERMEDIATE CROSS-CONNECT ICF IN-LINE CENTRIFUGAL FAN ID INSIDE DIAMETER IDC INSULATION DISPLACEMENT CONNECTOR IEF IN-LINE EXHAUST FAN IG ISOLATED GROUND IN INCHES IN WG INCHES OF WATER, GAUGE (PRESSURE) IW INDIRECT WASTE JB JUNCTION BOX JP JOCKEY PUMP KEF KITCHEN EXHAUST FAN KHWST KITCHEN HOT WATER STORAGE TANK KVA KILOVOLT AMPERE KW KILOWATT KWH KITCHEN WATER HEATER L LENGTH L/LS LOCAL SOUND SPEAKER LA LABORATORY COMPRESSED AIR LAN LOCAL AREA NETWORK LAT LEAVING AIR TEMPERATURE LAV LAVATORY LBS/HR POUNDS PER HOUR LF LINEAR FEET LG LABORATORY GAS LIQ LIQUID LPC LOW PRESSURE CONDENSATE LPS LOW PRESSURE STEAM LV LABORATORY VACUUM LVP LOW VIDEO PRESENTATION LWT LEAVING WATER TEMPERATURE MA MEDICAL COMPRESSED AIR MA MILLIAMPERE MA MIXED AIR MAGP MASTER ALARM GAS PANEL MAX MAXIMUM MBH BTU PER HOUR (THOUSAND) MC MAIN CROSS-CONNECT MC METAL CLAD CABLE MCC MOTOR CONTROL CENTER MD MOTORIZED DAMPER MECH MECHANICAL MFF MIXED FLOW FAN MFR MANUFACTURER MH METAL HALIDE MIN MINIMUM MLO MAIN LUGS ONLY MM MULTI-MODE MPC MEDIUM PRESSURE CONDENSATE MPS MEDIUM PRESSURE STEAM MUAU MAKE UP AIR UNIT MV MEDICAL VACUUM N2 NITROGEN N2O NITROUS OXIDE N.C. NORMALLY CLOSED N.O. NORMALLY OPEN N/A NOT APPLICABLE NEC NATIONAL ELECTRICAL CODE NIC NOT IN CONTRACT NL NIGHT LIGHT WALK-THRU NTS NOT TO SCALE O OXYGEN OA OUTSIDE AIR OD OUTSIDE DIAMETER OF OPTICAL FIBER ORD OVERFLOW ROOF DRAIN ORWL OVERFLOW RAIN WATER LEADER P POLE PA PUBLIC ADDRESS PBX PRIVATE BRANCH EXCHANGE PCD PUMPED CONDENSATE DRAIN (COOLING) PCR PUMPED CONDENSATE RETURN (STEAM) PD PRESSURE DROP PE PRIMARY ELECTRIC SERVICE PF POWER FACTOR PF PROPELLER FAN PH / Ø PHASE PIV POST INDICATOR VALVE PLEF PLENUM FAN PLUF PLUG FAN PNL PANELBOARD POE POWER OVER ETHERNET PP PATCH PANEL PR PAIR PRESS PRESSURE PRV PRESSURE REDUCING VALVE PSI POUNDS PER SQUARE INCH PT POTENTIAL TRANSFORMER PVC POLYVINYL CHLORIDE QTY QUANTITY R RELAY RA RETURN AIR RAF RETURN AIR FAN RD ROOF DRAIN RE EXISTING EQUIPMENT TO BE DISCONNECTED AND REMOVED REF REFRIGERANT PIPING (MULTIPLE PIPES) REF ROOF EXHAUST FAN REG REGISTER RF RELIEF FAN RGS RIGID GALVANIZED STEEL CONDUIT RH RELATIVE HUMIDITY RHC REHEAT COIL RHG REFRIGERANT HOT GAS RL EXISTING EQUIPMENT TO BE DISCONNECTED, REMOVED AND RELOCATED RM ROOM RMS ROOT MEAN SQUARED RO REVERSE OSMOSIS WATER RPD REDUCED PRESSURE DEVICE RPM REVOLUTIONS PER MINUTE RTU ROOF TOP UNIT RU RACK UNIT RV RADON VENT RWL RAIN WATER LEADER s SWITCHED RECEPTACLE S SLEEVE(S) S SOIL S&R SUPPLY AND RETURN SA SUPPLY AIR SAC SHOP AIR COMPRESSOR SCC SPRINKLER CONTROL CABINET SCP STEAM CONDENSATE PUMP SD SMOKE DAMPER SE SECONDARY ELECTRIC SERVICE SEP SEWAGE EJECTOR PUMP SG STEAM GENERATOR SM SINGLE-MODE SP STANDPIPE SP STATIC PRESSURE SP SUMP PUMP SPDT SINGLE POLE DOUBLE THROW SPEC SPECIFICATION SPK SPRINKLER SPK/SP COMBINED SPRINKLER/ STANDPIPE SPST SINGLE POLE SINGLE THROW SQ SQUARE SS STAINLESS STEEL ST STORM STD STANDARD STP SHIELDED TWISTED PAIR SUCT SUCTION SW SWITCH SWBD SWITCHBOARD SWH STEAM WATER HEATER T'STAT THERMOSTAT TAF TUBEAXIAL FAN TAG IDENTIFICATION OF EQUIPMENT TBB TELECOMMUNICATIONS BONDING BACKBONE TD TEMPERATURE DIFFERENCE TE TELECOMMUNICATIONS ENCLOSURE TEBC TELECOMMUNICATIONS EQUIPMENT BONDING CONDUCTOR TEL TELECOMMUNICATIONS SERVICE TEMP TEMPERATURE TGB TELECOMMUNICATIONS GROUNDING BUSBAR TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR TMV THERMOSTATIC MIXING VALVE TP TAMPERPROOF TP TRAP PRIMER TR TELECOMMUNICATIONS ROOM TS TELEPHONE SERVICE TSP TOTAL STATIC PRESSURE TV TELEVISION TVS TRANSIENT VOLTAGE SUPPRESSOR TW TEMPERED WATER TWR TEMPERED WATER RETURN TX TRANSFORMER TYP TYPICAL U USB UF UNFUSED UH UNIT HEATER UPF UPBLAST PROPELLER ROOF EXHAUST FAN UPS UNINTERRUPTIBLE POWER SUPPLY UR URINAL USF UTILITY SET FAN UTP UNSHIELDED TWISTED PAIR V VENT V VOICE V VOLTAGE VA VOLT AMPERE VAC VACUUM VAF VANEAXIAL FAN VAV VARIABLE AIR VOLUME VD VOLUME DAMPER VEL VELOCITY VFC VARIABLE FREQUENCY CONTROLLER VIF VERIFY IN FIELD VOIP VOICER OVER INTERNET PROTOCOL VOL VOLUME VTR VENT THRU ROOF W WALL TELEPHONE W WASTE W WATT WAO WORK AREA OUTLET WAP WIRELESS ACCESS POINT WB WET BULB TEMPERATURE WC WATER CLOSET WEF WALL EXHAUST FAN WG WIREGUARD WH WALL HYDRANT (HOSE BIBB) WHA WATER HAMMER ARRESTER WI WIDTH WP WEATHERPROOF WPD WATER PRESSURE DROP WTG WALL TRANSFER GRILLE WTR WATER WV WASTE AND VENT COMBINATION WWM WELDED WIRE MESH ZVB MEDICAL GAS ZONE VALVE BOX MEPT ABBREVIATIONSMEPT ABBREVIATIONS GENERAL 1. THE PROJECT DRAWINGS AND SPECIFICATIONS ARE BASED ON THE CONSTRUCTION SPECIFICATIONS INSTITUTE (CSI) DOCUMENTATION FORMAT. SPECIFICATION AND DRAWING CONTENTS ARE ARRANGED BY TOPIC AND CATEGORY AND ARE NOT INTENDED TO AWARD DIVISION OF WORK. 2. THE INTENT OF THESE DOCUMENTS IS FOR THE MEP TRADES TO FURNISH AND INSTALL COMPLETE MECHANICAL AND ELECTRICAL SYSTEMS. THE SPECIFIED FIRE PROTECTION, PLUMBING, HVAC, ELECTRICAL AND SPECIAL SYSTEMS SHALL BE COMPLETE IN ALL RESPECTS; OPERATIONAL, TESTED, ADJUSTED, CALIBRATED, APPROVED BY THE AUTHORITIES HAVING JURISDICTION AND READY FOR BENEFICIAL USE BY THE OWNER. 3. UTILIZING THE DESIGN INTENT MODEL: THE CONTRACT DOCUMENTS ARE SOLELY A TWO DIMENSIONAL SET OF DOCUMENTS. IF UTILIZED, THE DESIGN INTENT MODEL HAS BEEN DEVELOPED TO A LEVEL OF DEVELOPMENT LOD 200 AND LOD 300 MODEL CONTENT REQUIREMENTS AS DEFINED BY AIA G-202-2013. THE DESIGN INTENT MODEL IS A THREE DIMENSIONAL TOOL UTILIZED TO CREATE A TWO DIMENSIONAL CONTRACT DOCUMENT. A TWO DIMENSIONAL CONTRACT DOCUMENT REQUIRES, FOR REASON OF CLARITY AND OTHERWISE, THAT COMPONENTS OF THE DESIGN NOT BE MODELED IN THREE DIMENSIONS AND/OR THAT THE MODEL BE FORMED IN A WAY THAT CONSTRUCTION MEANS AND METHODS WILL DICTATE OTHER WAYS OF PERFORMING THE INSTALLATION. THE DESIGN INTENT MODEL IS NOT A SUBSTITUTE FOR THE CONTRACTORS’ COORDINATION PROCESS AS OUTLINED IN THE CONTRACT DOCUMENTS; FULL COORDINATION REMAINS THE RESPONSIBILITY OF THIS CONTRACTOR AND THEIR SUB-CONTRACTORS. THE CONTENTS OF THE MODEL ARE NOT TO BE USED FOR THE BASIS OF DETAILED COST ESTIMATING, COORDINATING EQUIPMENT LOCATIONS AND SYSTEMS ROUTING WITH ALL OTHER TRADES. THE CONTRACTOR MAY USE THE DESIGN INTENT MODEL TO HELP ESTABLISH THE BACKGROUNDS AND/OR STARTING POINT FOR THE COORDINATION DRAWINGS BASED ON THE STIPULATIONS OF THE RELEASE FORM THAT CAN BE PROVIDED IF AND WHEN THE MODEL IS REQUESTED. 4. CREATION OF THE CONSTRUCTION COORDINATION MODEL: CREATE A CONSTRUCTION COORDINATION MODEL. THE CONSTRUCTION COORDINATION MODEL SHALL BE DEVELOPED TO A MINIMUM LEVEL OF DEVELOPMENT LOD 400 MODEL CONTENT REQUIREMENTS AS DEFINED BY AIA G-202-2013. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR CREATING AND MAINTAINING A CONSTRUCTION COORDINATION MODEL AND COORDINATION DRAWINGS AS REQUIRED FOR DETAILED CONSTRUCTION INSTALLATION AND COORDINATION WITH ALL OTHER TRADES. 5. DIFFERENCES BETWEEN THE DESIGN INTENT MODEL AND THE CONSTRUCTION COORDINATION MODEL AND/OR ACTUAL INSTALLATION LOCATION, MEANS AND METHODS ARE INCLUDED IN THIS CONTRACT AND SHALL NOT CONSTITUTE A CHANGE ORDER ON THE BASIS OF DRAWING, ENGINEERING AND/OR COORDINATION TIME. 6. THE TRADES SHALL OBTAIN AND REVIEW ALL CONTRACT DOCUMENTS BEFORE SUBMITTING A BID. INFORMATION IS PROVIDED ON THE VARIOUS DRAWINGS, SCHEDULES, SPECIFICATIONS AND ALL OF THE VARIOUS DOCUMENTS IN THE BIDDING PACKAGE. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY AND FORM A TOTAL PROJECT DESIGN AND INFORMATION SOURCE FOR CONSTRUCTION PURPOSES. 7. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED IN THE CONTRACT. COORDINATE LOCATIONS OF EQUIPMENT WITH OTHER TRADES BEFORE AND DURING CONSTRUCTION. ANY MODIFICATION TO THE EQUIPMENT LAYOUT, REQUIRED FOR INSTALLATION, IS TO BE PERFORMED UNDER THE CONTRACT AGREEMENT, AT NO ADDITIONAL COST. 8. REFER TO THE ARCHITECTURAL DRAWINGS FOR THE EXACT LOCATION AND MOUNTING HEIGHTS OF VARIOUS EQUIPMENT. ALL SUCH EQUIPMENT AND EQUIPMENT COLORS AND FINISHES SHALL BE COORDINATED WITH THE ARCHITECT. MOUNTING HEIGHTS SHALL BE APPROVED BY THE ARCHITECT. 9. PERFORM ALL WORK IN COMPLIANCE WITH THE SPECIFICATIONS, APPLICABLE CODES, ORDINANCES AND THE REGULATORY AGENCIES HAVING JURISDICTION. THE SPECIFICATIONS MAY EXCEED THE REQUIREMENTS OF THE CODE, IN WHICH CASE, THE SPECIFICATION MUST BE FOLLOWED. 10. INSTALL ALL EQUIPMENT IN ACCESSIBLE LOCATIONS. WHERE EQUIPMENT MUST BE INSTALLED ABOVE AN INACCESSIBLE CEILING OR BEHIND A WALL, AN APPROPRIATE ACCESS DOOR SHALL BE PROVIDED AND THE LOCATION SHALL BE COORDINATED WITH THE ARCHITECT. 11. COORDINATE PIPING AND CONDUITS ENTERING OR LEAVING THE BUILDING WITH THE SITE CONTRACTOR(S) BEFORE INSTALLATION. COORDINATE INVERTS WITH THE STRUCTURE AND SYSTEM REQUIREMENTS PRIOR TO INSTALLATION. 12. WHERE A CONFLICT OCCURS BETWEEN THE DOCUMENTS, IT SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. CARRY AS PART OF THE BID THE LARGER QUANTITY AND/OR MORE EXPENSIVE ITEM(S). 13. BEFORE INSTALLATION, COORDINATE THE WORK WITH OWNER-FURNISHED EQUIPMENT, INCLUDING REQUIRED SERVICE CONNECTIONS, FACTORY START UPS AND INSTALLATION OF FIELD DEVICES. 14. PROVIDE THE REQUIRED/SPECIFIED SLEEVES AND SEALS FOR PIPES OR CONDUIT PENETRATING INTERIOR AND EXTERIOR WALLS OR FLOOR SLABS. 15. INSTALL FLOOR-MOUNTED EQUIPMENT ON A CONCRETE HOUSEKEEPING PAD. 16. SEISMICALLY SUPPORT THE EQUPMENT AS REQUIRED BY CODE, THE AUTHORITY HAVING JURISDICTION, AND/OR AS SPECIFIED. SUBMIT ENGINEERED INSTALLATION DETAILS PER THE SPECIFICATIONS. THE CONTRACTOR'S SEISMIC ENGINEER SHALL REVIEW THE INSTALLATION AND PROVIDE A REPORT ON THE FINDINGS. 17. PROVIDE MEP COORDINATION DRAWINGS AS REQUIRED BY THE SPECIFICATIONS. 18. ENCLOSED CONTROLLERS SHALL BE PROVIDED BY THE CONTRACTOR PROVIDING THE EQUIPMENT REQUIRING AN ENCLOSED CONTROLLER. REQUIREMENTS ARE SPECIFIED UNDER DIVISION 26: "ENCLOSED CONTROLLERS". MOTOR EFFICIENCIES SHALL BE AS INDICATED IN THE SPECIFICATIONS. 19. PROVIDE PIPING, DUCTWORK, CONDUIT AND ALL OTHER ACCESSORIES AS REQUIRED FOR PROPER AND PROFESSIONAL SYSTEMS INSTALLATION. 20. TEST AND BALANCE ALL MECHANICAL AND ELECTRICAL SYSTEMS. PROVIDE ADDITIONAL TESTS AS REQUIRED BY THE SPECIFICATIONS. 21. DO NOT INSTALL PIPING OR DUCTWORK OVER ELECTRICAL PANELS, TRANSFORMERS, SPECIAL EQUIPMENT, ELEVATOR MACHINE ROOMS OR SHAFTS. 22. DO NOT INSTALL ANY SYSTEMS IN OR THROUGH ELEVATOR MACHINE ROOMS THAT DO NOT SERVE THE ROOM. MAINTAIN A MINIMUM OF SEVEN (7) FOOT HEAD CLEARANCE IN THE ELEVATOR MACHINE ROOM. 23. DO NOT INSTALL IN STAIRWELL OR STAIRWELL WALLS, PIPING, DUCTWORK, CONDUIT OR OTHER DEVICES OR EQUIPMENT NOT ASSOCIATED WITH OR SERVING THE RESPECTIVE STAIR. 24. PROVIDE PIPE EXPANSION COMPENSATION FOR THE VARIOUS PIPING SYSTEMS. SUBMIT ENGINEERED DETAILS FOR APPROVAL AND VERIFY INSTALLATION IS IN ACCORDANCE WITH CODE. THE CONTRACTOR'S CONSULTING ENGINEER SHALL REVIEW THE INSTALLATION AND PROVIDE A REPORT OF THE FINDINGS. 25. PROVIDE ADDITIONAL TRANSITIONS AND OFFSETS IN ALL PIPING, DUCTWORK OR CONDUIT FOR COORDINATION WITH BUILDING STRUCTURE AND CONSTRUCTION. 26. NO MECHANICAL OR ELECTRICAL SYSTEM COMPONENTS MAY BE SUPPORTED FROM STRUCTURAL BRACED FRAMES. RENOVATION 1. THIS PROJECT INVOLVES THE RENOVATION OF AN EXISTING FACILITY; BEFORE SUBMITTING THE BID, CONTRACTORS SHALL VISIT THE SITE AND BECOME THOROUGHLY FAMILIAR WITH THE EXISTING CONDITIONS UNDER WHICH THE PROJECT IS TO BE COMPLETED. 2. CONTRACTORS SHALL BE HELD RESPONSIBLE FOR ASSUMPTIONS, OMISSIONS OR ERRORS MADE AS A RESULT OF FAILURE TO BECOME FULLY FAMILIAR WITH THE EXISTING CONDITIONS. 3. IT IS NOT THE INTENT OF THESE DOCUMENTS TO SHOW EVERY DEVICE, APPURTENANCE, PIPE, WIRE OR CONDUIT TO BE REMOVED. MEP EQUIPMENT, UNITS, AND SYSTEMS NOT BEING REUSED, SHALL BE REMOVED IN THEIR ENTIRETY INCLUDING ASSOCIATED HANGERS, SUPPORTS, BASES, PADS, PIPES, DUCTS, CONDUITS, WIRES, INSULATION, AND CONTROLS BACK TO THE POINT OF ORIGIN. 4. EQUIPMENT, PIPING, OR CONDUIT SHALL NOT BE ABANDONED IN-PLACE UNLESS SPECIFICALLY SO NOTED. 5. PROPERLY DISPOSE OF DEMOLISHED EQUIPMENT IN COMPLIANCE WITH CODES, REGULATIONS, AND DEEP STANDARDS. TURN OVER TO THE OWNER EQUIPMENT SO INDICATED. 6. RELOCATE EXISTING EQUIPMENT, DEVICES, PIPING, WIRING, AND RELATED SYSTEMS AS REQUIRED FOR CONSTRUCTION PURPOSES. ALL EXISTING SYSTEMS SHALL BE FULLY OPERATIONAL, INCLUDING RECONNECTION TO SERVICES AND UPGRADED SYSTEMS. ALL RELOCATED EQUIPMENT SHALL BE PROTECTED DURING CONSTRUCTION. 7. PROVIDE TEMPORARY CONNECTIONS AND SYSTEM MODIFICATIONS AS REQUIRED FOR CONSTRUCTION AND PHASING PURPOSES. 8. INCLUDE ALL WORK REQUIRED TO ALLOW PHASED CONSTRUCTION WHEN NECESSARY. COORDINATE WITH GENERAL CONTRACTOR/CONSTRUCTION MANAGER FOR PHASING REQUIREMENTS. 9. ALL EXISTING EQUIPMENT, FIXTURES, AND DEVICES TO BE REMOVED AND RELOCATED SHALL BE FIELD VERIFIED FOR EXACT QUANTITY AND CONDITION. KEEP AN ACCURATE RECORD OF STORED EQUIPMENT AND ITS CONDITION. 10. REBALANCE NEW AND EXISTING MECHANICAL AND ELECTRICAL SYSTEMS ASSOCIATED WITH THE RENOVATION, INCLUDING RENOVATED AREAS AND AREAS AFFECTED BY SYSTEM MODIFICATIONS. 11. SYSTEMS REQUIRING TO REMAIN IN OPERATION DURING DEMOLITION SHALL BE CAREFULLY PROTECTED FROM DAMAGE AND CONTAMINATION BY THE CONSTRUCTION PROCESS. FIRE PROTECTION 1. PROVIDE ALL PIPING, SUPPORTS, AND EQUIPMENT NECESSARY FOR A FULL COVERAGE SYSTEM IN CONFORMANCE WITH NFPA, STATE AND LOCAL CODES, THE OWNER'S INSURANCE COMPANY, AND THE AUTHORITY HAVING JURISDICTION. 2. COORDINATE SPRINKLER HEAD LOCATIONS WITH THE LATEST ARCHITECTURAL REFLECTED CEILING PLANS, HOWEVER, FULL SPRINKLER COVERAGE REMAINS THE RESPONSIBILITY OF THE INSTALLING PROFESSIONAL. 3. REFER TO THE LATEST ARCHITECTURAL PLANS FOR CEILING CONSTRUCTION, ELEVATIONS, SECTIONS, DETAILS, LOCATIONS OF SOFFITS, CEILING POCKETS, STEPPED CEILING, SKYLIGHT, ETC. PROVIDE ADDITIONAL PIPING AND SPRINKLER HEADS AS THE CONDITION WARRANTS. 4. WHERE SPRINKLER HEADS ARE SHOWN ON CONTRACT DOCUMENTS, THEY ARE INDICATED FOR GENERAL COORDINATION PURPOSES ONLY AND DO NOT RELIEVE THE CONTRACTOR FROM FULL COMPLIANCE WITH APPLICABLE CODES AND GOOD INSTALLATION PRACTICE. 5. ALL EQUIPMENT MAIN DRAINS AND INSPECTOR TEST DRAINS SHALL BE PIPED TO THE EXTERIOR OF THE BUILDING. PROVIDE CONCRETE SPLASH GUARDS AT EACH DRAIN LOCATION TO AVOID SOIL EROSION OR OTHER DAMAGE. 6. BRANCH PIPING TO SPRINKLER HEADS SHALL NOT BE INSTALLED DIRECTLY FROM THE BOTTOM OF HORIZONTAL SPRINKLER MAINS OR BRANCH LINES. ALL CONNECTIONS TO SPRINKLER HEADS SHALL BE MADE FROM THE TOP OR SIDES OF THE MAIN OR BRANCH LINES. 7. LOCATIONS OF FIRE DEPARTMENT CONNECTIONS AND FIRE PROTECTION SERVICE CONTROL VALVES SHALL BE COORDINATED WITH THE AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION. PLUMBING 1. IT IS NOT THE INTENT OF THE DRAWINGS TO SHOW INDIVIDUAL BRANCH PIPING TO EACH PLUMBING FIXTURE; ONLY THE BRANCH PIPING TO GROUPS OF FIXTURES IS INDICATED. EACH AND EVERY FIXTURE SHALL BE PROPERLY PIPED TO WATER, WASTE, AND VENT PIPING SYSTEMS. REFER TO THE PLUMBING SCHEDULES FOR INDIVIDUAL PIPE SIZES TO EACH FIXTURE. 2. INSTALL TRAP PRIMERS FOR ALL FLOOR DRAINS AND WATER HAMMER ARRESTORS AT ALL QUICK CLOSING VALVES (FLUSH VALVES, SOLENOID VALVES, ETC.); SIZE SHALL BE BASED ON FIXTURE UNITS PER PDI STANDARDS. 3. INCLUDE NECESSARY PIPING OFFSETS AND TRANSITIONS AS REQUIRED TO INSTALL THE PLUMBING FIXTURES AND EQUIPMENT. PIPING, DRAINS AND VENTS SHALL BE THOROUGHLY CLEANED AND FLUSHED IMMEDIATELY BEFORE PROJECT COMPLETION. PROVIDE CERTIFICATION ON CONTRACTOR'S LETTER HEAD THAT THIS WORK HAS BEEN COMPLETED. 4. DOMESTIC WATER DROPS AND RISERS INSTALLED IN EXTERIOR WALLS SHALL BE INSTALLED ON THE WARM SIDE OF INSULATION AND THE LOCATION SHALL BE MADE INFILTRATION FREE. 5. PROVIDE COOLING COIL CONDENSATE TRAPS AND DRAIN PIPING FOR ALL MECHANICAL EQUIPMENT REQUIRING SAME; PIPE CONDENSATE DRAINS BY GRAVITY TO INDIRECT WASTE FLOOR DRAIN OR OTHER APPROVED LOCATION. 6. COORDINATE EXACT LOCATION OF UNDERGROUND UTILITIES (WATER, GAS, SANITARY, ETC.) EXITING OR ENTERING THE BUILDING WITH THE SITE CONTRACTOR, GENERAL CONTRACTOR OR CONSTRUCTION MANAGER. HVAC 1. PROVIDE THROTTLING VALVES AND SHUT-OFF VALVES AS SPECIFIED IN ADDITION TO THOSE INDICATED ON THE DOCUMENTS. 2. PROVIDE DUCT TAKE-OFF TYPES AND VOLUME DAMPERS PER THE SPECIFICATIONS AND DUCT TAKE-OFF DETAILS ON DRAWINGS. TAKE-OFFS SHOWN ON FLOOR PLANS DO NOT REPRESENT THE SPECIFIC TYPE OF TAKE-OFF REQUIRED. CONSULT THE DETAILS AND SPECIFICATIONS. 3. INSTALL SMOKE DETECTORS FOR AIR HANDLING EQUIPMENT PER THE MEP DETAILS. PROVIDE SMOKE DAMPERS AND INSTALL ASSOCIATED SMOKE DETECTORS AT DUCT PENETRATIONS OF SMOKE-BARRIERS, AT AIR HANDLING UNITS, AND AT ELEVATOR SHAFT VENTS PER THE MEP DETAILS AND CODE REQUIREMENTS. 4. PROVIDE AN AUTOMATIC TEMPERATURE CONTROL SYSTEM COMPLETE IN ALL REGARDS. ALL ZONES, VAV'S AND SYSTEMS SHALL BE THERMOSTATICALLY CONTROLLED. REVIEW THE PLANS AND SPECIFICATIONS OF ALL MEP TRADES FOR A COMPLETE SCOPE OF THE WORK. 5. PIPING SHALL BE SUPPORTED FROM STRUCTURE ABOVE. TO MAXIMIZE HEAD ROOM, INSTALL TIGHT TO BOTTOM OF BEAMS WHEN RUNNING PERPENDICULAR TO BEAM. INSTALL PIPING TIGHT TO FLOOR SLAB WHEN RUNNING PARALLEL TO BEAM. PROVIDE ALL NECESSARY FITTINGS AND TRANSITIONS. 6. PROVIDE AIR VENTS AT ALL HIGH POINTS AND DRAINS AT ALL LOW POINTS. 7. PROVIDE FIRE DAMPERS AT DUCT PENETRATIONS OF FIRE-RATED CONSTRUCTION, INCLUDING WALLS, SHAFTS AND FLOOR PENETRATIONS. COORDINATE WITH ARCHITECTURAL DRAWINGS. 8. PAINT AND INTERNALLY INSULATE ALL EXPOSED DUCTWORK PER THE SPECIFICATIONS. 9. PROVIDE PRESSURE RELIEF DOORS FOR AIR SYSTEMS PER THE SPECIFICATIONS. 10. PROVIDE MOTORIZED DAMPERS AT ALL PERMANENT OPENINGS (EXHAUST, SUPPLY, RELIEF, O.A. INTAKES, MAKE-UP AIR, SMOKE VENTS, ETC.) EXCEPT DRYER, KITCHEN, AND FUME EXHAUST AND PROVIDE A MEANS TO CONTROL THE DAMPER OPERATION. ELECTRICAL 1. IT IS NOT THE INTENTION TO SHOW EVERY FITTING, WIRE, OR DEVICE. ALL SUCH ITEMS SHALL BE FURNISHED AND INSTALLED AS NECESSARY FOR A COMPLETE SYSTEM. 2. CONCEAL RACEWAYS IN FINISHED AREAS. RACEWAYS WITHIN MECHANICAL AND ELECTRICAL ROOMS MAY BE SURFACE-MOUNTED. 3. DO NOT INSTALL CONDUIT IN CONCRETE SLABS, UNLESS SPECIFICALLY APPROVED BY THE STRUCTURAL ENGINEER. 4. EACH INDIVIDUAL ELECTRICAL HOMERUN SHOWN ON FLOOR PLANS, DETAILS, OR SCHEDULES SHALL BE PROVIDED IN A DEDICATED RACEWAY. 5. SERIES RATING OF PROTECTIVE/ISOLATION DEVICES AND/OR ELECTRICAL EQUIPMENT IS UNACCEPTABLE. ALL ELECTRICAL EQUIPMENT AND PROTECTIVE DEVICES SHALL BE “FULLY” RATED. 6. PROVIDE POWER TO MECHANICAL EQUIPMENT SHOWN ON MECHANICAL PLANS, RISERS, SCHEDULES, OR IN SPECIFICATIONS. MECHANICAL EQUIPMENT IS NOT NECESSARILY SHOWN ON ELECTRICAL PLANS. REFER TO MECHANICAL PLANS AND SCHEDULES ON MEP DRAWINGS FOR LOCATIONS AND SPECIFIC ELECTRICAL REQUIREMENTS. COORDINATE EXACT LOCATION AND ORIENTATION OF EQUIPMENT WITH OTHER TRADES. 7. PROVIDE INTERFACE CONNECTIONS TO THE FIRE ALARM SYSTEM AND FIRE PROTECTION SYSTEM EQUIPMENT SHOWN ON PLANS, SCHEDULES, RISERS, OR IN SPECIFICATIONS. THIS EQUIPMENT IS NOT NECESSARILY SHOWN ON ELECTRICAL PLANS. COORDINATE EXACT LOCATION AND QUANTITY WITH THE FIRE PROTECTION CONTRACTOR. 8. FURNISH AND COORDINATE THE LOCATION OF DUCT SMOKE DETECTORS. PROVIDE AND WIRE DEVICES TO THE FIRE ALARM SYSTEM; FURNISH DETECTORS TO THE MECHANICAL CONTRACTOR FOR INSTALLATION. 9. MAKE CONNECTIONS TO LUMINAIRES IN ACCORDANCE WITH THE DETAILS SHOWN ON THE DRAWINGS. PROVIDE SWITCHING, AND OCCUPANCY SENSORS AND NORMAL CIRCUIT MONITORING AS PER THE DETAILS. 10. EXIT SIGNS ARE NOT NECESSARILY SHOWN WIRED ON THE DRAWINGS. PROVIDE SINGLE CIRCUIT EXIT SIGNS WITH BATTERY BACKUP; CONNECT POWER TO THE UN-SWITCHED LIGHTING CIRCUIT IN THE AREA SERVED BY THE EXIT SIGN. 11. CONNECT EMERGENCY FLUORESCENT POWER UNITS (BATTERY BALLAST(S)) OR EMERGENCY LIGHTING UNITS TO LINE SIDE OF SWITCHING. THESE UNITS MUST MONITOR THE NORMAL LIGHTING CIRCUIT WITHIN THE SPACE. 12. INSTALL WIRING FROM AN EMERGENCY SOURCE OR EMERGENCY DISTRIBUTION OVERCURRENT PROTECTION TO EMERGENCY LOADS ENTIRELY INDEPENDENT OF ALL OTHER WIRING AND EQUIPMENT EXCEPT WITHIN THE EQUIPMENT, EXIT SIGNS, AND EMERGENCY LUMINAIRES. 13. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLANS FOR THE EXACT LOCATION OF ALL CEILING MOUNTED LUMINAIRES SHOWN ON ELECTRICAL PLANS. 14. BOND ALL OF THE FOLLOWING SERVICES TOGETHER PER THE NEC: POWER, TELECOMMUNICATIONS, CATV AND LIGHTNING PROTECTION. 15. PROVIDE BRANCH CIRCUITS FROM ELECTRICAL PANELS WITH SUFFICIENT CAPACITY AND SPACE FOR MISCELLANEOUS SYSTEMS. THESE SYSTEMS SHALL INCLUDE, BUT ARE NOT LIMITED TO, MONITORING SYSTEMS, CONTROL PANELS, ANNUNCIATOR PANELS, PLUMBING ACCESSORIES, ETC. FURNISH AND INSTALL ALL BRANCH CIRCUIT WIRING AND CIRCUIT BREAKERS FOR THE EQUIPMENT SHOWN. 16. PROVIDE GROUND FAULT RECEPTACLES WITHIN SIX FEET (6') OF SINK OR OTHER WATER SOURCE; PROVIDE GROUND FAULT WEATHER PROOF RECEPTACLES AT ALL EXTERIOR LOCATIONS. TECHNOLOGY 1. COORDINATE WITH CONSTRUCTION MANAGER, OTHER TRADES AND THE OWNER DURING ALL PHASES. ALL COMMUNICATIONS MUST BE MAINTAINED AT ALL TIMES UNLESS PHASING REQUIRES OTHERWISE. INTERRUPTIONS AND SHUTDOWNS SHALL BE SCHEDULED IN ADVANCE AND APPROVED FOR TIME TO COMPLETE WORK. TAG CABLES TO REMAIN DURING ALL PHASES TO PROPERLY KEEP THE TELECOMMUNICATIONS ACTIVE. UPON COMPLETION OF CONSTRUCTION, ANY CABLES THAT ARE NOT ACTIVE OR TAGGED TO REMAIN FOR FUTURE USE SHALL BE REMOVED PER THE NEC. 2. BEFORE CONSTRUCTION CAN BEGIN IN ANY TELECOMMUNICATIONS ROOM (TR) OR TELECOMMUNICATIONS EQUIPMENT ROOM (ER) THE CONTRACTOR SHALL COORDINATE LAYOUT LOCATIONS AND CLEARANCES OF ALL EQUIPMENT WITH THE TECHNOLOGY OWNER TO APPROVE THE INSTALLATIONS AND ANY FUTURE SPACE. 3. REFER TO THE ARCHITECTURAL DRAWINGS FOR THE EXACT LOCATION AND MOUNTING HEIGHTS OF EQUIPMENT. ALL SUCH EQUIPMENT AND COLORS SHALL BE COORDINATED WITH THE ARCHITECT. CONTACT ARCHITECT FOR ANY CLARIFICATION. 4. REFER TO REFLECTED CEILING PLANS FOR FLUSH MOUNTED CEILING DEVICES. 5. PROVIDE SEPARATION BETWEEN RACEWAY, CABLES AND OTHER SOURCES (EMI) PER ANSI/TIA-569-B. 6. ELBOW RADIUS FOR RACEWAYS SMALLER THAN 2" TO BE (6) SIX TIMES THE RACEWAY DIAMETER. ELBOW RADIUS FOR CONDUITS 2" OR LARGER TO BE (10) TEN TIMES THE RACEWAY DIAMETER. 7. ALL EMPTY RACEWAYS SHALL BE PROVIDED WITH A (PLENUM RATED, IF PLENUM CEILING SPACE) NYLON PULL CORD. 8. COORDINATE PROPER METHODS FOR PENETRATIONS WITH FIRESTOPPING AS REQUIRED THROUGH FIRE/SMOKE RATED CONSTRUCTION PER DIVISION 07 SPECIFICATIONS. 9. NO PENETRATIONS ARE PERMITTED INTO ANY STAIRWELLS EXCEPT FOR SYSTEMS SERVING THAT STAIRWELL. 10. CONDUITS AND CABLING FOR SERVICE ENTRANCE SHALL BE PROVIDED PER SITE UTILITY DRAWINGS, TECHNOLOGY/ELECTRICAL POWER DRAWINGS AND DIVISION 26 SPECIFICATIONS. COORDINATE LOCATION OF DEMARCATION POINT. 11. LADDER RACKS, CONDUITS, D-RINGS, ETC. FOR CABLE SUPPORT IN ANY TELECOMMUNICATIONS ROOM (TR) OR TELECOMMUNICATIONS EQUIPMENT ROOM (ER) SHALL BE PROVIDED PER PLANS AND DIVISION 26 SPECIFICATIONS. 12. CABLE TRAYS, CONDUITS, SLEEVES AND J-HOOKS FOR FIBER BACKBONE CABLING AND OTHER BACKBONE CABLING SHALL BE PROVIDED PER DIVISION 26 SPECIFICATIONS. 13. CABLE TRAY, SURFACE MOUNTED RACEWAYS, CONDUITS, SLEEVES AND J-HOOKS FOR HORIZONTAL CABLING FROM COMMUNICATIONS EQUIPMENT ROOM TO THE TELECOMMUNICATIONS OUTLETS/CONNECTORS SHALL BE PROVIDED PER DIVISION 26 SPECIFICATIONS. 14. COORDINATE THE INSTALLATION OF ALL CABLE TRAYS, SURFACE MOUNTED RACEWAYS, CONDUITS, SLEEVES AND J-HOOKS PER DIVISION 26 SPECIFICATIONS. 15. COORDINATE OUTLET INSTALLATIONS, WALL: RECESSED OR SURFACE; CEILING; FLOOR: SLEEVE OR INFLOOR SYSTEM; UTILITY COLUMN; PER TECHNOLOGY/ELECTRICAL POWER DRAWINGS AND DIVISION 26 SPECIFICATIONS. 16. COORDINATE EXACT LOCATION(S) FOR MECHANICAL EQUIPMENT ETHERNET CONNECTION TERMINATION(S) WITH DIVISION 23. MEPT GENERAL NOTESMEPT GENERAL NOTES CODES LISTED BELOW APPLY TO ALL DRAWINGS AND SPECIFICATIONS ON THIS PROJECT ● MASSACHUSETTS BASIC BUILDING CODE - EIGHTH EDITION ● THE FOLLOWING AS REFERENCED AND MODIFIED BY THE ABOVE CODE: ○ 2009 INTERNATIONAL BUILDING CODE (IBC) WITH MASSACHUSETTS AMENDMENTS PER 780 CMR ○ 780 CMR 9.00 - FIRE PROTECTION SYSTEMS ▪ 527 CMR CHAPTER MASS FIRE PENETRATION REGULATIONS ▪ 2009 INTERNATIONAL FIRE CODE ▪ MASSACHUSETTS GENERAL LAW CHAPTER 148 - FIRE PREVENTION - SECTION 26 ○ 780 CMR 13.00 - ENERGY EFFICIENCY AMENDMENTS ▪ 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ▪ 2010 ANSI/ASHRAE/IESNA STANDARD 90.1 - ENERGY STANDARD FOR BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS ○ 780 CMR CHAPTER 27.00 - ELECTRICAL ▪ 527 CMR CHAPTER 12 - MASSACHUSETTS ELECTRICAL CODE (AMENDMENTS) ▪ 527 CMR CHAPTER 27 - EMERGENCY AND STANDBY POWER SYSTEMS ▪ 2014 NFPA 70 - NATIONAL ELECTRICAL CODE (NEC) ▪ NFPA 110 - 2002 ○ 780 CMR 28.00 - MECHANICAL SYSTEMS ▪ 2009 INTERNATIONAL MECHANICAL CODE (IMC) ○ 780 CMR 29.00 - PLUMBING SYSTEMS ▪ 248 CMR CHAPTER 10 - MASSACHUSETTS UNIFORM STATE PLUMBING CODE ○ ACCESSIBILITY ▪ 521 CMR - MASSACHUSETTS ARCHITECTURAL ACCESS BOARD REGULATIONS ▪ MASSACHUSETTS GENERAL LAWS CHAPTER 22 ▪ 2004 ICC/ANSI A117.1 - GUIDELINES FOR ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES ● 2014 FGI GUIDELINES FOR DESIGN AND CONSTRUCTION OF HEALTH CARE FACILITIES ● THE JOINT COMMISSION ● THE AMERICANS WITH DISABILITY ACT, TITLE II, INCLUDING THE AMERICANS WITH DISABILITIES ACT ACCESSIBILITYGUIDELINES (ADAAG) AND ADA REGULATIONS ● OCCUPATIONAL SAFETY AND HEALTH ACT, TITLE 29/LABOR ● GENERAL LAWS OF MASSACHUSETTS EHC XXX XXX FDC PRE DRY SP SPK SP/SPK F O MV N2O TWR TW CD ST RWL ORWL IW S S A 2 3 4 P L E R D D3 T K K3 K4 SC MC OC OC VS VC T OC (1) 20A- 1P LV-1MFSVFCVDFDZONE VALVE BOX HOME RUN CIRCUIT BREAKER SIZE PANEL DESIGNATION ALARM PANEL SLIDE VACUUM OUTLET OXYGEN OUTLET NITROUS OXIDE MEDICAL VACUUM OXYGEN SHOWER HEAD - LOCATION T&P RELIEF VALVE ROOF DRAIN FLOOR DRAIN TEMPERED WATER RETURN TEMPERED WATER CONDENSATE DRAIN STORM BURIED RAIN WATER LEADER OVERFLOW RAIN WATER LEADER INDIRECT WASTE SOIL OR WASTE BURIED SOIL OR WASTE ABOVE GRADE HOT WATER RECIRCULATING HOT WATER POINT OF NEW TO EXISTING CONNECTION, INCLUDING TRANSITIONS THICK, DASHED LINES INDICATE EXISTING ITEMS TO BE REMOVED THIN, LIGHT LINES INDICATE EXISTING ITEMS OR RACEWAY TO REMAIN IN PLACE AND BE REUSED THICK, DARK SOLID LINES INDICATE NEW OR RELOCATED ITEMS OR NEW RACEWAY AND WIRING FIRE SERVICE COMBINATION SP / SPK MAIN WET SPRINKLER MAIN STANDPIPE MAIN DRY SPRINKLER MAIN PREACTION SPRINKLER MAIN FIRE DEPT. CONNECTION SUPPLY LINE FIRE HOSE VALVE RISER (SPRINKLER OR STANDPIPE) PENDANT SPRINKLER HEAD CONCEALED PENDANT SPRINKLER HEAD SEMI-RECESSED UPRIGHT SPRINKLER HEAD SIDEWALL SPRINKLER HEAD EXISTING SPRINKLER HEAD TO REMAIN EXISTING SPRINKLER HEAD TO BE REMOVED DRY PENDANT SPRINKLER DRY SIDEWALL SPRINKLER WIRE GUARD OVER SPRINKLER HEAD EXTENDED COVERAGE SPRINKLER HIGH TEMPERATURE SPRINKLER FULLY SPRINKLERED SPACE PARTIALLY SPRINKLERED SPACE NON-SPRINKLERED SPACE DP DS WG EC H RECTANGULAR, FLAT OVAL OR ROUND AIR DUCT AIR DUCT WITH ACOUSTICAL LINING SUPPLY AIR DUCT UP SUPPLY AIR DUCT DOWN RETURN AIR DUCT UP RETURN AIR DUCT DOWN EXHAUST AIR DUCT UP EXHAUST AIR DUCT DOWN ACCESS DOOR FLEXIBLE DUCT CONNECTION CEILING SUPPLY DIFFUSERS CEILING RETURN / EXHAUST GRILLE HARD DUCTED DIFFUSER OR GRILLE WITH FULL SIZE BOTTOM TAKE-OFF DIRECTION OF SUPPLY OR OUTDOOR AIRFLOW DIRECTION OF RETURN OR EXHAUST AIRFLOW DOOR UNDERCUT VOLUME DAMPER FIRE DAMPER VAV BOX W / UNIT TYPE SUPPLY PIPING. REFER TO ABBREVIATION LIST FOR DESIGNATION (XXX) RETURN PIPING. REFER TO ABBREVIATION LIST FOR DESIGNATION (XXX) ELECTRICAL HEATING CABLE. REFER TO ABBREVIATION LIST FOR DESIGNATION (XXX) SMOKE DAMPER SYSTEM AND ASSOCIATED DEVICES PER SPECIFICATIONS AND MEP DETAILS COMBINATION FIRE AND SMOKE DAMPER MOTORIZED DAMPER HUMIDIFIER TUBE / PANEL DUCT SMOKE DETECTOR WITH REMOTE INDICATING LIGHT AND TEST SWITCH DUCT STATIC PRESSURE SENSOR DIFFERENTIAL PRESSURE SENSOR VARIABLE FREQUENCY CONTROLLER ROOM THERMOSTAT OR TEMPERATURE SENSOR ROOM TEMPERATURE WITH CARBON DIOXIDE SENSOR CARBON MONOXIDE SENSOR CARBON DIOXIDE SENSOR HUMIDISTAT FINNED TUBE RADIATION VAV PERFORMANCE TAG FIN TUBE TAG PIPE ANCHOR BACKFLOW PREVENTER STRAINER OR STRAINER WITH BLOW- DOWN VALVE HOSE END, CAP AND CHAIN WALL CLEANOUT OR BLIND FLANGE "P" TRAP PIPE TEE DOWN IN-LINE EXPANSION COMPENSATOR FLOOR CLEANOUT STEAM TRAP ASSEMBLY STEEL PENETRATION / PIPE SLEEVE PIPE ELBOW UP OR PIPE TEE UP PIPE ELBOW DOWN COMPANION FLANGE PIPE CAP OR CAPPED END OF PIPE UNION PIPE GUIDES PUMP WATER HAMMER ARRESTOR TAKEOFF FROM TOP OF MAIN PIPE TAKEOFF FROM BOTTOM OF MAIN PIPE DIRECTION OF FLUID FLOW VALVE ON RISER VALVE ON DROP METERING ORIFICE AIR VENT FLOW SENSOR PIPE DROP WITH VALVE 2-WAY CONTROL VALVE 3-WAY CONTROL VALVE BALL VALVE CALIBRATED BALANCING VALVE SHUT-OFF VALVE (SEE SPECIFICATIONS FOR APPLICATION TYPE) BUTTERFLY VALVE CHECK VALVE THERMOSTATIC MIXING VALVE GLOBE VALVE GATE VALVE PRESSURE REDUCING VALVE GAS COCK TRIPLE DUTY VALVE OS&Y VALVE FUSOMATIC VALVE (FIREMATIC) DRAIN VALVE WITH HOSE END, CAP & CHAIN OR WALL HYDRANT / HOSE BIBB MOTORIZED BUTTERFLY VALVE PRESSURE RELIEF SAFETY VALVE AQUASTAT SOLENOID VALVE TEMPERATURE SENSOR WITH SEPARABLE SOCKET IN IMMERSIBLE WELL TEMPERATURE GAUGE WITH SEPARABLE SOCKET IN IMMERSIBLE WELL THERMOMETER WITH SEPARABLE SOCKET IN IMMERSIBLE WELL PRESSURE GAUGE PRESSURE SENSOR WITH SYPHON (STEAM) FLEXIBLE CONNECTOR RECTANGULAR DUCT ROUND DUCT 20x12 20Ø PENDANT LIGHT FIXTURE ELECTRICAL SYMBOLS LINEAR LIGHT FIXTURE PENDANT MOUNTED LIGHT FIXTURE RECESSED DOWNLIGHT FIXTURE RECESSED WALL WASH DOWNLIGHT FIXTURE SURFACE-MOUNTED LIGHT FIXTURE WALL-MOUNTED LIGHT FIXTURE RECESSED OR SURFACE-MOUNTED FIXTURE OPEN LAMP LIGHT FIXTURE LIGHTING TRACK (NUMBER OF FIXTURES INDICATED ON PLANS) CEILING OR WALL-MOUNTED EXIT LIGHT FIXTURE CEILING OR WALL-MOUNTED EMERGENCY LIGHT UNIT LIGHT FIXTURE (PART OF EMERGENCY ILLUMINATION SYSTEM) SINGLE-POLE SWITCH DOUBLE-POLE SWITCH 3-WAY SWITCH 4-WAY SWITCH SINGLE-POLE SWITCH (TOGGLE LIGHTED - LOAD ON) LOW VOLTAGE SWITCH EMERGENCY OFF SWITCH EMERGENCY LIGHTING RELAY SINGLE-POLE DIMMER SWITCH THREE-WAY DIMMER SWITCH SINGLE-POLE TIMER SWITCH SINGLE-POLE KEYED SWITCH KEYED, 3-WAY SWITCH KEYED, 4-WAY SWITCH SPEED CONTROL SWITCH MOMENTARY CONTACT SWITCH OCCUPANCY SENSOR W / POWER PACK (CEILING / WALL) OCCUPANCY SENSOR SWITCH VACANCY SENSOR SWITCH VACANCY SENSOR CONTROL SWITCH MARK TIME SWITCH DAYLIGHTING SENSOR TIME CLOCK PHOTOCELL EMERGENCY OFF SWITCH WITH COVER SURFACE MOUNTED FACTORY PRE-WIRED MULTI-OUTLET RACEWAY SURFACE MOUNTED RACEWAY. SEE PLANS OR SCHEDULE FOR QUANTITY OF DEVICES ELECTRICAL HEATING CABLE POWER WIRING SWITCH LEG WIRING CONTROL WIRING FURNITURE PARTITION WHIP CONNECTION FLOOR SERVICE FITTING WITH OUTLET(S); REFER TO SCHEDULE (X) POKE-THRU ASSEMBLY WITH OUTLET(S); REFER TO SCHEDULE (X) WALL BOX WITH PLATE FOR FURNITURE POWER WITH WHIP CONNECTIONS WALL BOX WITH PLATE FOR FURNITURE TELECOMMUNICATIONS WITH WHIP CONNECTIONS FEEDER TAG SURFACE ELECTRICAL PANEL, 480Y/277 OR 480 VOLT SURFACE ELECTRICAL PANEL, 208Y/120 OR 208 VOLT SURFACE SPECIAL-PURPOSE PANEL OR CABINET FLUSH ELECTRICAL PANEL, 480Y/277 VOLT FLUSH ELECTRICAL PANEL, 208Y/120 VOLT FLUSH SPECIAL-PURPOSE PANEL OR CABINET TRANSFORMER TRAP PRIMER COLD WATER H SP DP NS AS AS S V O E * XXX XXX T H Tc CO CO2 TC PC DL FB-X PT-X T P EHC TX TX FITTINGS AND VALVES HVAC SYMBOLSFIRE PROTECTION SYMBOLSGENERAL SYMBOLS PLUMBING SYMBOLS MEDICAL GAS SYMBOLS DUCT SIZING DS VENT PCD PUMPED CONDENSATE DRAIN -N -G ---A 999 999 999 WIRING - REFER TO ABBREVIATION LIST (XXX)XXX FLAT OVAL DUCT20/12 EMERGENCY EYEWASH / DELUGE SHOWER SUB LETTERS "EX" INDICATES EXISTING EQUIPMENT TO REMAIN INTACT SUB LETTER "RE" INDICATES EXISTING EQUIPMENT TO BE DISCONNECTED AND REMOVED SUB LETTER "RL" INDICATES EXISTING EQUIPMENT TO BE DISCONNECTED, REMOVED AND RELOCATED SUB LETTER "NL" INDICATES NEW LOCATION OF RELOCATED EQUIPMENT SUB LETTER "NR" INDICATES NEW EQUIPMENT TO REPLACE EXISTING SUB LETTER "RR" INDICATES REMOVE EQUIPMENT AND REPLACE ON NEW SURFACE EX RE RL NL NR RR TP M COMMUNICATIONS SYMBOLS CARD READER ELECTRONIC DOOR LATCH RETRACTION ELECTRONIC DOOR STRIKE MAGNETIC DOOR LOCK ACCESS CONTROL PANEL ML ES CR SECURITY SYMBOLS ACCESS CONTROL INTRUSION DETECTION SURVEILLANCE DOOR CONTACT SWITCH KEYPAD GLASS BREAK ALARM AUDIBLE SIREN/HORN VOICE OUTLET(S); REFER TO ABBREVIATIONS (X) REQUEST TO EXITREX MASTER INTERCOM STATION MOTION DETECTOR SOUND DETECTOR AS GB KP M SD DATA AND VOICE OUTLET(S); REFER TO ABBREVIATIONS (X) DATA OUTLET(S); REFER TO ABBREVIATIONS (X) SPECIALTY OUTLET(S); REFER TO ABBREVIATIONS (X) TELEVISION CATV OUTLET X X/X X X/X TV FLOOR SERVICE FITTING WITH OUTLET(S); REFER TO SCHEDULE (X) POKE-THRU ASSEMBLY WITH OUTLET(S); REFER TO SCHEDULE (X) TELEPOWER POLE WITH OUTLET(S); REFER TO SCHEDULE (X) CABLE TRAY SOUND SYSTEM VOLUME CONTROLLERVC AUDIO AMPLIFIER UNITAMP PUBLIC ADDRESS SPEAKER WITH CLOCK IN COMMON ENCLOSURE CEILING OR WALL-MOUNTED SPEAKER. REFER TO ABBREVIATIONS (X) FLOOR OR WALL-MOUNTED SOUND SYSTEM MICROPHONE FLUSH WALL-MOUNTED CLOCK PLYWOOD BACKBOARD TELECOMMUNICATIONS EQUIPMENT RACK (FOUR POST) TELECOMMUNICATIONS EQUIPMENT RACK (TWO POST) TELECOMMUNICATIONS GROUNDING BUSBAR (TGB) RACEWAY UP / DOWN S S M M C X X G C S DUPLEX RECEPTACLE DUPLEX RECEPTACLE SPLIT WIRED DOUBLE DUPLEX RECEPTACLE SINGLE RECEPTACLE SPECIAL PURPOSE RECEPTACLE; VERIFY NEMA CONFIGURATION WITH EQUIPMENT * * * * * * = a, b, clg, AF, GF IG OR TP. WHEN TAGGED IN THE ELECTRICAL SYMBOL LIST, REFER TO THE ABBREVIATION LIST * AD AD T ELR MIC INTERCOM STATIONIC ACP DOOR OPERATORDO PUSH PLATEPP ELECTRONIC DOOR HARDWIRINGEH INTRUSION DETECTION PANELIDP FLOW METERFM LV-1 HOME RUN PANEL DESIGNATION 20A-1P HOME RUN (TYPICAL) LV-1 XP/XXA HOME RUN PANEL DESIGNATION POLES/AMPERAGE HOME RUN LV-1 1,2,3 PANEL DESIGNATION CIRCUIT NUMBERS P P T T A TP-X TELEPOWER POLE WITH OUTLET(S); REFER TO SCHEDULE (X) FB-X PT-X TP-X VIDEO SURVEILLANCE FIXED CAMERA WITH HARDWARE VIDEO SURVEILLANCE PAN/TILT/ZOOM DOME CAMERA WITH HARDWARE VIDEO SURVEILLANCE FIXED DOME CAMERA WITH HARDWARE VIDEO MONITOR NETWORK VIDEO RECORDER DIGITAL VIDEO RECORDER VIDEO SURVEILLANCE FIXED CORNER CAMERA WITH HARDWARE VM NVR DVR BACKBONE COAX CABLING BACKBONE FIBER CABLING BACKBONE UTP COPPER CABLING HORIZONTAL COAX CABLING HORIZONTAL UTP COPPER CABLING CROSS-CONNECT EQUIPMENT RACK XXX X RISER DIAGRAM SYMBOLS 180° VIDEO SURVEILLANCE DOME CAMERA WITH HARDWARE 360° VIDEO SURVEILLANCE DOME CAMERA WITH HARDWARESDGROUNDING BUSBARG DOOR OPERATOR PUSH PLATE ENCLOSED SWITCH ELECTRIC MOTOR JUNCTION BOX MASTER FIRE ALARM PULL BOX VOICE FIRE ALARM CONTROL PANEL FIRE ALARM CONTROL PANEL FIRE ALARM REMOTE ANNUNCIATOR SMOKE DETECTOR HEAT DETECTOR REMOTE INDICATOR FIRE ALARM MANUAL PULL STATION FIRE ALARM HORN / STROBE FIRE ALARM SPEAKER / STROBE FIRE ALARM CHIME / STROBE FIRE ALARM STROBE FIRE ALARM CEILING-MOUNTED SPEAKER FIREFIGHTER'S TELEPHONE JACK PP DO C H F H S J F F F RI ANN FACP VFACP WALL CLOCK WITH HANGER TYPE OUTLET B PROGRAM BELL C CODE BLUE STATION NURSE CALL PATIENT STATION NURSE CALL DUTY STATION NURSE CALL STAFF STATION NURSE CALL EMERGENCY STATION NURSE CALL STAFF ASSISTANT STATION NURSE CALL AUXILIARY ALARM INPUT STATION MASTER NURSE CALL STATION MAIN NURSE CALL EQUIPMENT STATION NURSE CALL CORRIDOR LIGHT (CEILING OR WALL-MOUNTED) CB NP ND NS NC NA NI MNS MNC N N NURSE CALL SYMBOLS CALL-FOR-AID SWITCH W/ CORDE CALL-FOR-AID LIGHT AND BUZZER MAGNETIC DOOR LOCKML COMBINATION SMOKE/CARBON MONOXIDE DETECTIRS CO ELECTRICAL SYMBOLS Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085 NONE 8/16/2016 11:26:05 AMMEP-100 185-01-00 8/15/16 MEP GENERAL NOTES, ABBREVIATIONS, AND SYMBOL LISTS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER Issuance Schedule Number Date Description 1 2016.07.08 ADDENDUM #1 NOTE: THIS DETAIL IS FOR ALL EQUIPMENT SPECIFIED WITH VARIABLE FREQUENCY CONTROLLERS, CONTRACTOR TO PROVIDE WIRING BETWEEN REMOTE DISCONNECTS, STARTERS AND MOTORS. SEE EQUIPMENT SCHEDULES AND SPECIFICATIONS. TYPICAL MOTOR CONTROLLER AND VFC DETAIL NOT TO SCALE EQUIPMENT MOTOR (NOT SPECIFICALLY INDICATED ON FLOOR PLANS) EQUIPMENT TAG REFERENCES MEP AND OWNER SCHEDULES TERMINAL BOX EQUIPMENT TAG BRANCH CIRCUIT PER DIVISION 26 SPECIFICATIONS. RACEWAY MUST BE METALLIC. PVC NOT ALLOWED THE CONTRACTOR WHO FURNISHES EQUIPMENT REQUIRING A VARIABLE FREQUENCY CONTROLLER TO FURNISH THE VARIABLE FREQUENCY CONTROLLER WITH ALL OPTIONS AND ACCESSORIES PER DIVISION 26. "VARIABLE FREQUENCY CONTROLLERS." MOUNT ADJACENT TO EQUIPMENT IN SIGHT OF MOTOR SEE DIVISION 26 SPECIFICATIONS FOR BRANCH CIRCUIT REQUIREMENTS AND MEP SCHEDULES FOR SIZING CONTROL WIRING NON-FUSED ENCLOSED SWITCH PER DIVISION 26 SPECIFICATIONS WITH AUXILIARY CONTACTS. MOUNT IN SIGHT OF EQUIPMENT MOTOR. PROVIDE ONLY WHENEVER CONTROLLER AND SWITCH CANNOT BE MOUNTED WITHIN SIGHT OF EQUIPMENT VFC TYPICAL MOTOR CONTROLLER AND VFC DETAIL TYPICAL MOTOR, SWITCH AND CONTROLLER DETAIL EQUIPMENT TAG NOT TO SCALE BRANCH CIRCUIT PER DIVISION 26 SPECIFICATIONS. PROVIDE ADDITIONAL WIRING AS REQUIRED TO MATCH CONTROLLER THE CONTRACTOR WHO FURNISHES EQUIPMENT REQUIRING A MOTOR CONTROLLER TO FURNISH MOTOR CONTROLLERS FOR ALL MOTORS WITH ALL SPECIFIED OPTIONS AND ACCESSORIES PER DIVISION 26 SPECIFICATIONS. MOUNT ADJACENT TO EQUIPMENT FUSED ENCLOSED SWITCH PER DIVISION 26 SPECIFICATIONS. MOUNT IN SIGHT OF MOTOR CONTROLLER. EQUIPMENT MOTOR (NOT SPECIFICALLY INDICATED ON FLOOR PLANS) SEE DIVISION 26 SPECIFICATIONS FOR BRANCH CIRCUIT REQUIREMENTS AND MEP SCHEDULES FOR SIZING BRANCH CIRCUIT PER DIVISION 26 SPECIFICATIONS NON-FUSED ENCLOSED SWITCH PER DIVISION 26 SPECIFICATIONS WITH AUXILIARY CONTACTS. MOUNT IN SIGHT OF EQUIPMENT MOTOR. PROVIDE ONLY WHENEVER CONTROLLER AND SWITCH CANNOT BE MOUNTED WITHIN SIGHT OF EQUIPMENT NOTE: THIS DETAIL IS FOR ALL EQUIPMENT MOTORS. CONTRACTOR TO PROVIDE WIRING BETWEEN REMOTE DISCONNECTS, STARTERS AND MOTORS. SEE EQUIPMENT SCHEDULES AND SPECIFICATIONS. IF NOT NOTED OTHERWISE IN EQUIPMENT SCHEDULES, CONTRACTOR SHALL PROVIDE A COMBINATION MOTOR CONTROLLER/DISC. SWITCH. EQUIPMENT TAG REFERENCES MEP AND OWNER SCHEDULES TERMINAL BOX TYPICAL MOTOR, SWITCH AND CONTROLLER DETAIL TYPICAL EQUIPMENT CONNECTION DETAIL NOT TO SCALE FUSED ENCLOSED SWITCH PER DIVISION 26 SPECIFICATIONS. MOUNT IN SIGHT OF EQUIPMENT MOTOR NOTE: THIS DETAIL IS FOR ALL EQUIPMENT WHERE EQUIPMENT REQUIRES POWER AND WHERE THERE ARE NO MOTORS INVOLVED OR WHERE SPECIFICATIONS OR SCHEDULES FOR MULTIPLE MOTOR EQUIPMENT SPECIFICALLY INDICATE ONE POINT POWER CONNECTION. CONTRACTOR TO PROVIDE WIRING BETWEEN REMOTE DISCONNECTS, STARTERS AND MOTORS. SEE EQUIPMENT SCHEDULES AND SPECIFICATIONS. EQUIPMENT TAG EQUIPMENT TAG REFERENCES MEP AND OWNER SCHEDULES BRANCH CIRCUIT PER DIVISION 26 SPECIFICATIONS SEE DIVISION 26 SPECIFICATIONS FOR BRANCH CIRCUIT REQUIREMENTS AND MEP SCHEDULES FOR SIZING TERMINAL BOX TYPICAL EQUIPMENT CONNECTION DETAIL TYPICAL UNIT SMOKE/EMERGENCY SHUTDOWN CONTROL DETAIL EQUIPMENT TAGAIR DISTRIBUTION UNIT OR EXHAUST FAN MOTOR CONTROL INTERLOCK WIRING, PER DIVISION 23 "HVAC INSTRUMENTATION AND CONTROL" NOT TO SCALE EQUIPMENT MOTOR (NOT SPECIFICALLY INDICATED ON FLOOR PLANS). FIRE ALARM SYSTEM WIRING PER DIVISION 28 "FIRE ALARM" NOTE: APPLY THIS DETAIL TO THE SYSTEM DIAGRAMS ON THIS DRAWING FOR A COMPLETE SYSTEM. FACP EQUIPMENT TAG REFERENCES MEP AND OWNER SCHEDULES MOTOR CONTROLLER (UNIT OR REMOTE MOUNTED) FIRE ALARM SYSTEM ADDRESSABLE INTERFACE DEVICE PER DIVISION 28 "FIRE ALARM". LOCATE WITHIN 3 L.F. OF CONTROLLER. FIRE ALARM CONTROL PANEL PER DIVISION 28 "FIRE ALARM". PROVIDE MANUAL EMERGENCY SHUT DOWN SWITCH FOR EACH UNIT REQUIRING EMERGENCY SHUT DOWN AID TYPICAL UNIT SMOKE/EMERGENCY SHUTDOWN CONTROL DETAIL DS NOT TO SCALE TYPICAL SMOKE DAMPER ISOLATION CONTROL DETAIL SMOKE DAMPER POWER WIRING PER DIVISION 23 "HVAC INSTRUMENTATION AND CONTROL" SMOKE DAMPER OR COMBINATION SMOKE/FIRE DAMPER PER DIVISION 23 "DUCT ACCESSORIES" SMOKE DAMPER INTERLOCK WIRING PER DIVISION 23 "HVAC INSTRUMENTATION AND CONTROL" NOTE: APPLY THIS DETAIL TO THE SYSTEM DIAGRAMS ON THIS DRAWING FOR A COMPLETE SYSTEM. DAMPER END SWITCHES PER DIVISION 23 "DUCT ACCESSORIES" (OPEN AND CLOSED DAMPER POSITIONS) ATC SYSTEM WIRING FROM END SWITCHES PER DIVISION 23 "HVAC INSTRUMENTATION AND CONTROL" FIRE ALARM SYSTEM DUCT SMOKE DETECTOR WITH ADDRESSABLE RELAY PER DIVISION 28 "FIRE ALARM", LOCATE WITHIN 3 L.F. OF DAMPER FIRE ALARM SYSTEM WIRING PER DIVISION 28 "FIRE ALARM" HVAC DUCT END SWITCH INTERLOCK WIRING PER DIVISION 23 "HVAC INSTRUMENTATION AND CONTROL" SD AID AID TYPICAL SMOKE DAMPER ISOLATION CONTROL DETAIL EF EXHAUST FAN EMERGENCY SHUTDOWN SYSTEM DIAGRAM FACP NOTES: 1. SEE UNIT EMERGENCY SHUTDOWN CONTROL DETAILS FOR ADDITIONAL INFORMATION. 2. THIS DIAGRAM APPLIES TO ALL EXHAUST FANS 2000 CFM AND GREATER, EXCEPT SPECIALTY EXHAUST FANS SUCH AS GREASE, FUME, HAZARDOUS AND INDUSTRIAL. 3. SEE LISTED CFM IN EQUIPMENT SCHEDULES TO DETERMINE EXHAUST FANS OVER 2000 CFM. EXHAUST DUCT MOTOR CONTROL INTERLOCK WITH FIRE ALARM FIRE ALARM SYSTEM WIRING PER DIVISION 28 "FIRE ALARM" NOT TO SCALE MOTOR CONTROLLER (UNIT OR REMOTE MOUNTED) FIRE ALARM SYSTEM ADDRESSABLE INTERFACE DEVICE FIRE ALARM CONTROL PANEL W/ MANUAL EMERGENCY SHUT DOWN SWITCH AID EXHAUST FAN EMERGENCY SHUTDOWN SYSTEM DIAGRAM EQUIPMENT MOTOR (NOT SPECIFICALLY INDICATED ON FLOOR PLANS) NON-FUSED ENCLOSED SWITCH PER DIVISION 26 SPECIFICATIONS WITH AUXILIARY CONTACTS. MOUNT IN SIGHT OF EQUIPMENT MOTOR. PROVIDE ONLY WHENEVER CONTROLLER AND SWITCH CANNOT BE MOUNTED WITHIN SIGHT OF EQUIPMENT SEE DIVISION 26 SPECIFICATIONS FOR BRANCH CIRCUIT REQUIREMENTS AND MEP SCHEDULES FOR SIZING TYPICAL COMBINATION MOTOR CONTROLLER/DISC SWITCH DETAIL NOTE: THIS DETAIL IS FOR ALL EQUIPMENT MOTORS. CONTRACTOR TO PROVIDE WIRING BETWEEN REMOTE COMBINATION MOTOR CONTROLLER/ DISC SWITCH AND MOTORS. SEE EQUIPMENT SCHEDULES AND SPECIFICATIONS. IF NOT NOTED OTHERWISE IN EQUIPMENT SCHEDULES, CONTRACTOR SHALL PROVIDE A COMBINATION MOTER CONTROLLER/DISC. SWITCH. EQUIPMENT TAG NOT TO SCALE EQUIPMENT TAG REFERENCES MEP AND OWNER SCHEDULES BRANCH CIRCUIT PER DIVISION 26 SPECIFICATIONS. PROVIDE ADDITIONAL WIRING AS REQUIRED TO MATCH CONTROLLER THE CONTRACTOR WHO FURNISHES EQUIPMENT REQUIRING A COMBINATION MOTOR CONTROLLER/DISC SWITCH TO FURNISH MOTOR CONTROLLERS FOR ALL MOTORS WITH ALL SPECIFIED OPTIONS AND ACCESSORIES PER DIVISION 26 SPECIFICATIONS. MOUNT ADJACENT TO EQUIPMENT. DEVICE TO BE FUSED TERMINAL BOX TYPICAL COMBINATION MOTOR CONTROLLER/DISC SWITCH DETAIL SIDE ELEVATIONFRONT ELEVATION REDUCED PRESSURE ZONE BACKFLOW PREVENTER STRAINER MIN 30"MAX 60"MIN 18"UNION (TYPICAL) BALL VALVE (TYPICAL) OUTLET PIPE DISCHARGE LINE TO OUTSIDE F.D. OR RECEPTOR TEST COCK (TYPICAL) AIR GAP FITTING FINISH FLOOR MAINTAIN 8" (MINIMUM) CLEAR SPACE OFF THE WALL TO THE RPD MAINTAIN 12" (MINIMUM) CLEAR SPACE ABOVE RPD MAINTAIN A 30" (MIN.) DEEP X THE LENGTH OF THE RPD ASSEMBLY - CLEAR SPACE IN FRONT OF RPD OUTLET INLET NOT TO SCALE TYPICAL REDUCED PRESSURE ZONE BACKFLOW PREVENTER INSTALLATION DETAIL NOTES: 1. REFER TO DRAWINGS FOR UNIT SIZE(S). 2. THE RPD MOUNTING HEIGHT AND CLEARANCES INDICATED ABOVE SHALL BE MAINTAINED FOR PROPER ACCESS TO UNIT FOR MAINTENANCE, TESTING AND INSPECTION PURPOSES. 3. THE LOCATION AND MOUNTING HEIGHT OF THE RPD SHALL BE APPROVED BY THE WATER COMPANY PRIOR TO INSTALLATION. 4. ACCESS TO THIS UNIT SHALL NOT REQUIRE THE USE OF A LADDER OR REMOVAL OF CEILING TILES OR OTHER PERMANENT OR SEMI- PERMANENT CONSTRUCTION. 5. DO NOT INSTALL UNIT ABOVE A CEILING. 6. THE AREA WHERE THE RPD IS TO BE INSTALLED SHALL BE WELL LIT, PROVIDED WITH ADEQUATE DRAINAGE AND SHALL NOT BE SUBJECT TO FLOODING. NOTE: ALL ASSEMBLIES SHALL BE ADEQUATELY SUPPORTED AND/OR RESTRAINED TO PREVENT LATERAL MOVEMENT. PIPE HANGERS, BRACES, SADDLES, STANCHIONS, PIERS, ETC., SHOULD BE USED TO SUPPORT THE DEVICE AND SHOULD BE PLACED IN A MANNER THAT WILL NOT OBSTRUCT THE FUNCTION OF OR ACCESS TO THE RELIEFT VALVE, TEST PORTS OR VALVES. 0 0 0 0 0 TYPICAL REDUCED PRESSURE ZONE BACKFLOW PREVENTER INSTALLATION DETAIL TYPICAL DOUBLE CHECK VALVE BACKFLOW PREVENTER INSTALLATION DETAIL INLET FRONT ELEVATION SIDE ELEVATION NOT TO SCALE DOUBLE CHECK VALVE FOR FIRE PROTECTION SERVICE - WHERE NO CHEMICALS ARE USED (USE RPD WHERE CHEMICALS ARE USED) OS&Y GATE VALVE (TYPICAL) MAINTAIN 12" (MINIMUM) CLEAR SPACE ABOVE DCV MAINTAIN A 30" (MINIMUM) DEEP X THE LENGTH OF THE DCV ASSEMBLY - CLEAR SPACE IN FRONT OF DCV FINISH FLOOR MAX 60"MIN 30"MAINTAIN 8" MINIMUM CLEAR SPACE OFF THE WALL TO DCV NOTES: 1. REFER TO DRAWINGS FOR UNIT SIZE(S). 2. THE DCV MOUNTING HEIGHT AND CLEARANCES INDICATED ABOVE SHALL BE MAINTAINED FOR PROPER ACCESS TO UNIT FOR MAINTENANCE, TESTING AND INSPECTION PURPOSES. 3. THE LOCATION AND MOUNTING HEIGHT OF THE DCV SHALL BE APPROVED BY THE WATER COMPANY PRIOR TO INSTALLATION. 4. ACCESS TO THIS UNIT SHALL NOT REQUIRE THE USE OF A LADDER OR REMOVAL OF CEILING TILES OR OTHER PERMANENT OR SEMI- PERMANENT CONSTRUCTION. 5. DO NOT INSTALL UNIT ABOVE A CEILING. 6. THE AREA WHERE THE DCV IS TO BE INSTALLED SHALL BE WELL LIT, PROVIDED WITH ADEQUATE DRAINAGE AND SHALL NOT BE SUBJECT TO FLOODING. NOTE: ALL ASSEMBLIES SHALL BE ADEQUATELY SUPPORTED AND/OR RESTRAINED TO PREVENT LATERAL MOVEMENT. PIPE HANGERS, BRACES, SADDLES, STANCHIONS, PIERS, ETC., SHOULD BE USED TO SUPPORT THE DEVICE AND SHOULD BE PLACED IN A MANNER THAT WILL NOT OBSTRUCT ACCESS TO THE TESTING PORTS OR VALVES. OUTLET 0 000 TYPICAL DOUBLE CHECK VALVE BACKFLOW PREVENTER INSTALLATION DETAIL FIRE ALARM SYSTEM WIRING PER DIVISION 28 "FIRE ALARM" NOTE: APPLY THIS DETAIL TO THE SYSTEM DIAGRAMS ON THIS DRAWING FOR A COMPLETE SYSTEM. TYPICAL DUCT SMOKE DETECTOR DETAIL HVAC DUCT DUCT SMOKE DETECTOR W/SAMPLING TUBES PER DIVISION 28 FIRE ALARM, MOUNTED PER DIVISION 23/28 "METAL DUCTS" NOT TO SCALE DS TYPICAL DUCT SMOKE DETECTOR DETAIL Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085 NOT TO SCALE 8/16/2016 11:26:07 AMMEP-101 185-01-00 8/15/16 MEP DETAILS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER Issuance Schedule Number Date Description SHUT OFF SINGLE DUCT AIR TERMINAL UNIT SCHEDULE TAG SIZE CFM RANGE HEATING COIL PERFOMANCE NOM. CFM ROWS LAT GPM PIPE SIZE A 06 0-400 300 2 90 1 3/4" A1 06 0-400 NONE NONE NONE NONE NONE B 08 401-800 600 2 90 2 3/4" B1 08 401-800 NONE NONE NONE NONE NONE C 10 801-1200 900 2 90 3 1" C1 10 801-1200 NONE NONE NONE NONE NONE D 12 1201-1700 1275 2 90 4 1" D1 12 1201-1700 NONE NONE NONE NONE NONE E 14 1701-2300 1725 2 90 6 1" E1 14 1701-2300 NONE NONE NONE NONE NONE F 16 2301-3100 2325 2 90 8 1-1/4" F1 16 2301-3100 NONE NONE NONE NONE NONE GENERAL NOTES: AIR TERMINAL UNITS ARE BASED ON ENVIRO-TEC 0.5% MAXIMUM ALLOWABLE STATIC PRESSURE DROP FOR BOX AND REHEAT COIL HEATING COIL PERFORMANCE BASED ON NOMINAL CFM LISTED IN THE SCHEDULE @ 50° DEGREE F. ENTERING TEMPERATURE, 180° DEGREE F. ENTERING WATER TRMPERATURE, 150° DEGREE F. LEAVING WATER TEMPERATURE PERFORMANCE DATA TAG AIR TERMINAL UNIT TAG MAXIMUM COOLING CFM A ID TYPE MINIMUM COOLING CFM HEATING CFM GRILLE AND DIFFUSER SCHEDULE CEILING SUPPLY DIFFUSER DUCTED CEILING RETURN / EXHAUST GRILLE NON-DUCTED CEILING RETURN / EXHAUST GRILLE FLEXIBLE DUCT SIZES TO SUPPLY DIFFUSERS CFM SQUARE NECK SIZE ROUND NECK SIZE CFM NECK SIZE CFM NECK SIZE CFM SIZE 0-100 6 x 6 6"Ø 0-150 6 x 6 0-350 12 x 12 0-100 6"Ø 101-250 9 x 9 8"Ø 151-350 351-1200 22 x 22 101-250 8"Ø 251-400 12 x 12 10"Ø 351-650 251-400 10"Ø 401-600 15 x 15 12"Ø 651-1000 401-600 12"Ø 601-800 18 x 18 14"Ø 601-800 14"Ø TYPE MODEL DESCRIPTION A1 TDC SQUARE LOUVER FACE CEILING SUPPLY DIFFUSER WITH REMOVABLE CORE, LAY-IN, 1-WAY THROW. TRANSITIONAL ADAPTER. A2 TDC SQUARE LOUVER FACE CEILING SUPPLY DIFFUSER WITH REMOVABLE CORE, LAY-IN, 2-WAY CORNER THROW. TRANSITIONAL ADAPTER. A3 TDC SQUARE LOUVER FACE CEILING SUPPLY DIFFUSER WITH REMOVABLE CORE, LAY-IN, 3-WAY THROW. TRANSITIONAL ADAPTER. A4 TDC SQUARE LOUVER FACE CEILING SUPPLY DIFFUSER WITH REMOVABLE CORE, LAY-IN, 4-WAY THROW. TRANSITIONAL ADAPTER. A5 TDC SQUARE LOUVER FACE CEILING SUPPLY DIFFUSER WITH REMOVABLE CORE, LAY-IN, 2-WAY OPPOSITE THROW. TRANSITIONAL ADAPTER. AA 122 RL EXTRUDED ALUMINUM DOUBLE DEFLECTION SIDEWALL SUPPLY GRILLE. 2" ADJUSTABLE (AIRFLOW) SPACING. FRONT BLADES PARALLEL TO LONG DIMENSION. B 355 RL LOUVER TYPE CEILING/WALL RETURN OR EXHAUST GRILLE, 35° FIXED DEFLECTION, 1/2" SPACING WITH BLADES PARALLEL TO THE LONG DIMENSION. BB 112 RL EXTRUDED ALUMINUM DOUBLE DEFLECTION SIDEWALL SUPPLY GRILLE. 1-1/4" ADJUSTABLE (AIRFLOW) SPACING. FRONT BLADES PARALLEL TO LONG DIMENSION. PLUMBING FIXTURE SCHEDULE TYPE FIXTURE SOIL VENT COLD HOT MOUNT DESCRIPTION WC-1 WATER CLOSET - PATIENT - ADA 4" 2" 1" - WALL AMERICAN STANDARD "AFWALL MILLENNIUM FLOWISE ELONGATED" #3351.101, WALL HUNG WATER CLOSET. TOTO #TET1GNC-32 HYDROPOWER SELF GENERATING ELECTRONIC FLUSHOMETER, WITH 1" ANGLE STOP AND 1 1/2" VACUUM BREAKER, 1.6 GPF, MANUAL OVERRIDE, 24 HOUR AUTOMATIC FLUSH FOR TRAP SEAL PROTECTION. OLSONITE #95SSC WHITE OPEN FRONT SEAT LESS COVER, SELF-SUSTAINING CHECK HINGE. PROVIDE ADJUSTABLE VERTICAL SIPHON JET 500 LB NO-HUB CARRIER WITH HEAVY DUTY REAR ANCHOR TIE DOWN ZURN #Z1204-N4-X. WC-2 WATER CLOSET - STAFF - ADA 4" 2" 1" - WALL AMERICAN STANDARD "AFWALL MILLENNIUM FLOWISE ELONGATED" #3351.101, WALL HUNG WATER CLOSET. SLOAN #111-1.6 MANUAL FLUSH VALVE. OLSONITE #95SSC WHITE OPEN FRONT SEAT LESS COVER, SELF-SUSTAINING CHECK HINGE. PROVIDE ADJUSTABLE VERTICAL SIPHON JET 500 LB NO-HUB CARRIER WITH HEAVY DUTY REAR ANCHOR TIE DOWN ZURN #Z1204-N4-X. WC-3 WATER CLOSET - PATIENT - ADA 4"2" 1"-FLOOR AMERICAN STANDARD "RIGHT WIDTH FLOWISE ELONGATED" #3641.001, FLOOR MOUNTED WATER CLOSET. TOTO #TET1GNC-32 HYDROPOWER SELF GENERATING ELECTRONIC FLUSHOMETER, WITH 1" ANGLE STOP AND 1 1/2" VACUUM BREAKER, 1.6 GPF, MANUAL OVERRIDE, 24 HOUR AUTOMATIC FLUSH FOR TRAP SEAL PROTECTION. OLSONITE #95SSC WHITE OPEN FRONT SEAT LESS COVER, SELF-SUSTAINING CHECK HINGE. LV-1 LAVATORY - PATIENT & STAFF - ADA 1 1/2" 1 1/2" 1/2" 1/2"WALL AMERICAN STANDARD LUCERNE WALL HUNG LAVATORY #0355.012, WITH FAUCET HOLES 4" CENTERS. CHICAGO FAUCETS #895-317GN2FCAB HOT AND COLD WATER FAUCET, 1.5 GPM LAMINAR FLOW CONTROL INSERT IN SPOUT OUTLET, 5 1/4" RIGID / SWING GOOSENECK FAUCET, 4" WRISTBLADE HANDLES. SUPPLY RISERS SHALL BE 1/2"THD TYPE "L" COPPER WITH KEYSTOPS. PROVIDE CAST BRASS 17 GAUGE P- TRAP.TRUEBRO #82525 "SOFT-GUARD PLUS" INSULATION KIT. PROVIDE CONCEALED ARM CARRIER ZURN #1231 TO SUPPORT 250 LB LOAD CAPACITY. SK-1 HAND WASH SINK - VARIOUS AREAS 1 1/2" 1 1/2" 1/2" 1/2" COUNTER ELKAY "LUSTERTONE" GOURMET STAINLESS STEEL SINGLE BOWL TOP MOUNT QUICK-CLIP SINK #LRADQ172055, OVERALL DIMENSIONS 17"x20"x5-1/2", 18 GAUGE 304 STAINLESS STEEL, REAR CENTER DRAIN. CHICAGO FAUCETS #786-GN8FCXKABCP, DECK MOUNTED 8" FIXED CENTERS CONCEALED HOT AND COLD WATER FAUCET, 8" FLOW CONTROL RIGID / SWING GOOSENECK SPOUT, 4" WRISTBLADE HANDLES, 1/4 TURN OPERATING CARTRIDGE, 1.5 GPM LAMINAR FLOW CONTROL INSERT IN SPOUT OUTLET. SUPPLY RISERS SHALL BE 1/2"THD TYPE "L" COPPER WITH KEYSTOPS. PROVIDE CAST BRASS 17 GAUGE P- TRAP. SK-2 SOILED WORKROOM SINK 1 1/2" 1 1/2" 1/2" 1/2" FLOOR AMERICAN STANDARD LUCERNE WALL HUNG LAVATORY #0356.015, WITH FAUCET HOLES 8" CENTERS. CHICAGO FAUCETS #786-GN2FCXKABCP HOT AND COLD WATER FAUCET, 1.5 GPM LAMINAR FLOW CONTROL INSERT IN SPOUT OUTLET, 5 1/4" RIGID / SWING GOOSENECK FAUCET, 4" WRISTBLADE HANDLES. SUPPLY RISERS SHALL BE 1/2"THD TYPE "L" COPPER WITH KEYSTOPS. PROVIDE CAST BRASS 17 GAUGE P- TRAP.TRUEBRO #82525 "SOFT-GUARD PLUS" INSULATION KIT. PROVIDE CONCEALED ARM CARRIER ZURN #1231 TO SUPPORT 250 LB LOAD CAPACITY. SK-3 STAFF BREAK ROOM & STRETCHER WAITING ROOM SINK 1 1/2" 1 1/2" 1/2" 1/2" COUNTER ELKAY "LUSTERTONE" GOURMET STAINLESS STEEL SINGLE BOWL TOP MOUNT QUICK-CLIP SINK #LRADQ172055, OVERALL DIMENSIONS 17"x20"x5-1/2", 18 GAUGE 304 STAINLESS STEEL, REAR CENTER DRAIN. CHICAGO FAUCETS #786-GN8FCXKABCP, DECK MOUNTED 8" FIXED CENTERS CONCEALED HOT AND COLD WATER FAUCET, 8" FLOW CONTROL RIGID / SWING GOOSENECK SPOUT, 4" WRISTBLADE HANDLES, 1/4 TURN OPERATING CARTRIDGE, 1.5 GPM LAMINAR FLOW CONTROL INSERT IN SPOUT OUTLET. SUPPLY RISERS SHALL BE 1/2"THD TYPE "L" COPPER WITH KEYSTOPS. PROVIDE CAST BRASS 17 GAUGE P- TRAP. PLUMBING SPECIALTIES SCHEDULE TYPE SPECIALTY ITEM DESCRIPTION WB-1 WATER / WASTE CONNECTION BOX GUY GRAY MODEL #MWB26 CENTER DRAIN 20 GAUGE STEEL RECESSED BOX WITH POWDER COATED FINISH, 1/2" QUARTER TURN WATER SUPPLY VALVE WITH HOSE CONNECTION AND 2" SLIPNUT DRAIN CONNECTION. ZVB ZONE VALVE BOX BEACON MEDAES ZVB2-EF-ENG #4107219442 TWO VALVE BOX 1 1/2" & 2" (MV, O2) GAUGES AND SENSORS REQUIRED SHALL BE BEACON MEDAES (1) #4107655177 & (1) #4107655178. V, O, S MEDICAL GAS WALL OUTLETS/INLETS & SLIDES BEACON MEDAES GEMINI 3-QUICK CONNECT OUTLETS, INLETS AND SLODES AS FOLLOWS: OXYGEN-#234510-00 ROUGH-IN ASSEMBLY AND #234610-00 FINAL ASSEMBLY MED VAC-#234513-00 ROUGH-IN ASSEMBLY AND #234613-00 FINAL ASSEMBLY SLIDE-#234500-00 ROUGH-IN ASSEMBLY AND #234500-00 FINAL ASSEMBLY SA-1 WATER HAMMER ARRESTOR PRECISION PLUMBING PRODUCTS MODEL #SC-750B SYSTEM RATED WATER HAMMER ARRESTOR SA-2 WATER HAMMER ARRESTOR PRECISION PLUMBING PRODUCTS MODEL #SC-500A SYSTEM RATED WATER HAMMER ARRESTOR PUMP SCHEDULE TAG MFR TYPE SERIES / SIZE MODEL NO. MINIMUM EFFICIENCY GPM FT OF HEAD (TDH) P-1 BELL & GOSSETT END SUCT. 1510 2 1/2 BB 75.5 225 75 P-2 BELL & GOSSETT END SUCT. 1510 2 1/2 BB 75.5 225 75 TAG RPM MOTOR HP VFC SERVES OPERATION P-1 1750 7.5 YES HEATING HOT WATER RUN P-2 1750 7.5 YES HEATING HOT WATER STANDBY ELECTRICAL TAG VOLTS / PHASE HOME RUN BRANCH CIRCUIT SIZE SW / FUSE P-1 480/3 SEE FLOOR PLANS SEE FLOOR PLANS - P-2 480/3 SEE FLOOR PLANS SEE FLOOR PLANS - PROVIDE MAXIMUM IMPELLER DIAMETER FOR NON-OVERLOADING PERFORMANCE FOR SPECIFIED HORSEPOWER. TRIM AND BALANCE IMPELLER AFTER SYSTEM HAS BEEN INSTALLED AND OPERATED AIR COOLED CONDENSING UNIT SCHEDULE TAG MFR MODEL AMBIENT TEMP (°F) CAPACITY (TONS) REFRIGERANT TYPE SUCTION TEMP (°F) CU-S1 TRANE TTA120H4 95 10 R-410A 45 CU-S2 TRANE TTA073G4 95 6 R-410A 45 TAG NUMBER OF REFRIG. CIRCUITS NUMBER OF STEPS UNLOADING EER MCA MDP SERVES CU-S1 2 2 11.5 21.9 X DX-S1 CU-S2 2 2 13 15 X DX-S2 ELECTRICAL TAG VOLTS / PHASE HOME RUN BRANCH CIRCUIT SIZE SW / FUZE CU-S1 460/3 SEE FLOOR PLANS SEE FLOOR PLANS 30A/25A CU-S2 460/3 SEE FLOOR PLANS SEE FLOOR PLANS 20A/20A REFRIGERANT COILS CHEDULE TAG MFR / MODEL CFM EAT DB / WB (°F) LAT DB / WB (°F) HEIGHT (IN) LENGTH (IN) DX-S1 TRANE / DFDB33 5600 71 / 62 55 / 55 33 90 DX-S2 TRANE / DFDB24 3000 71 / 62 55 / 55 24 60 TAG CAPACITY MBH TOTAL/SENSIBLE MAX VELOCITY (FPM) MAX APD (IN WC) NUMBER OF CIRCUITS REFRIGERANT TYPE MINIMUM ROWS DX-S1 126 / 98 265 0.201 QUARTER R-410A 4 DX-S2 71 / 53 288 0.202 HALF R-410A 4 PANELBOARD SCHEDULE GENERAL NOTES: 1. SEE SPECIFICATION SECTION "PANELBOARDS" FOR FEATURES OF PANELBOARDS 2. VERIFY SIZE, QUANTITY AND TYPES OF CIRCUIT BREAKERS IN PANELBOARDS WITH PLANS, RISERS, SCHEDULES AND SPECIFICATION. 3. ALL PANELBOARDS ARE LIGHTING AND APPLIANCE BRANCH CIRCUIT PANELBOARDS UNLESS LISTED OTHERWISE. NOTES: A. SPD PANELBOARD. B. DISTRIBUTION PANELBOARD. C. PROVIDE PANELBOARD WITH ISOLATED EQUIPMENT GROUND BUS BAR. D. PROVIDE PANELBOARD WITH STAINLESS STEEL TRIM AND DOOR. E. PROVIDE PANELBOARD WITH INTEGRAL LIGHTING CONTACTOR. F. PROVIDE PANELBOARD WITH AUXILIARY GUTTER. G. PROVIDE 30 MA GROUND FAULT CIRCUIT INTERRUPTER CIRCUIT BREAKERS. H. PROVIDE 5 MA GROUND FAULT CIRCUIT INTERRUPTER CIRCUIT BREAKERS. I. PROVIDE PANELBOARD WITH NEMA 4X ENCLOSURE. J. LIGHTING CONTROL PANEL WITH ABILITY TO TAKE INPUT FROM LOW VOLTAGE DEVICES (SWITCHES, OCCUPANCY SENSORS, ETC.). PANELBOARD NAME VOLTAGE MAIN OCPD SIZE MAIN BUS SIZE MOUNTING POLE CAPACITY MIN. AISC RATING NOTES CIRCUITS AMPS POLES BRANCH FEEDER SPARE NOTES SL1 208/120V 100A MCB 100A SURFACE 60 22K 20 1 54 6 SL2 208/120V 200A MCB 200A SURFACE 84 22K 40 2 3 20 1 16 16 30 2 3 20 2 2 Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-0858/16/2016 11:26:08 AMMEP-102 185-01-00 8/15/16 MEP SCHEDULES COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER GENERAL NOTES: 1. BIDS SHALL BE BASED ON THE LUMINAIRE SCHEDULE BELOW AND THE SPECIFICATIONS. REFER TO THE ELECTRICAL SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 2. ALL LUMINAIRES BELOW ARE LED. LUMINAIRE SCHEDULE TYPE MANUFACTURER FIXTURE DESCRIPTION VOLTS LAMPING KELVIN OUTPUT A1 METALUMEN "SCENE" SERIES SCE2L40K22SDWL41T1NN OR APPROVED EQUAL 2X2 RECESSED LED FLAT PANEL TROFFER. DIMMING DRIVER 120 V 4000 K 2290 LUMENS 24 WATTS A2 METALUMEN "SCENE" SERIES SCE2L40K22SDWL51T1NN OR APPROVED EQUAL 2X2 RECESSED LED FLAT PANEL TROFFER. DIMMING DRIVER 120 V 4000 K 3280 LUMENS 37 WATTS A3 METALUMEN "SCENE" SERIES SCE2L40K22SDWL51T1NN OR APPROVED EQUAL 2X2 RECESSED LED FLAT PANEL TROFFER. DIMMING DRIVER 120 V 4000 K 3280 LUMENS 37 WATTS A4 KENALL "MAC" SERIES MAC14G67L40KDCC1120IBHDAMF OR APPROVED EQUAL 1X4 RECESSED LED LUMINAIRE WITH MATT WHITE REFLECTOR. DIMMING DRIVER 120 V 4000 K 2095 LUMENS 72 WATTS B1 H.E. WILLAMS '50' SERIES 50G-S22-L20/840-S-AF12125-X-DIM-UNV OR APPROVED EQUAL 2X2 RECESSED LENSED LED TROFFER WITH 0.125" ACRYLIC DIFFUSER, MATT WHITE REFLECTOR. DIMMING DRIVER 120 V 4000 K 2000 LUMENS 22 WATTS C1 H.E. WILLIAMS "75L" SERIES 75L-4-L20/840-A12125-DRV-120 OR APPROVED EQUAL 4' SURFACE MOUNTED LED STRIP LIGHT WITH ACRYLIC LENS 120 V 4000 K 2000 LUMENS 23 WATTS D1 H.E. WILLAMS 'L60' SERIES L60-L11/840-CS-MWT-DIM-120 OR APPROVED EQUAL 6" RECESSED ROUND LED DOWNLIGHT INTEGRAL DIMMING DRIVER 120 V 4000 K 1100 LUMENS 17 WATTS U1 H.E. WILLIAMS "1SF" SERIES 1SF-2-L12/840-AF12125-WRS/120-DRV-120OR APPROVED EQUAL UNDERCABINET TASK LIGHT. EXTRUDED WRAPAROUND OPAL DIFFUSER ACRYLIC LENS. ROCKER SWITCH 120 V 4000 K 14 WATTS W1 EUREKA 'MOONRISE PLUS 3540' SERIES 354023LED.11.40120VDVSCWH3980 OR APPROVED EQUAL WALL MOUNTED LED FIXTURE WITH ACRYLIC DIFFUSER 120 V 4000 K 1300 LUMENS 12 WATTS W2 LEDALITE "TRUE GROOVE" SERIES 2923LAENW0411EW OR APPROVED EQUAL WALL MOUNTED INDIRECT LED FIXTURE WITH EXTRUDED ACRYLIC LENS 120 V 4000 K 3200 LUMENS 25.8 WATTS X1 PHILIPS CHLORIDE 'CXX' SERIES CXL3RW OR APPROVED EQUAL LED POLYCARBONATE TYPE EXIT SIGN. HOUSING SHALL HAVE 6" HIGH LETTERING TO MEET CODE. 120 V 1.2 WATTS X2 PHILIPS CHLORIDE 'CXX' SERIES CXL3RW OR APPROVED EQUAL LED POLYCARBONATE TYPE EXIT SIGN. HOUSING SHALL HAVE 6" HIGH LETTERING TO MEET CODE. 120 V 1.2 WATTS X3 PHILIPS CHLORIDE 'AMS' SERIES AMS120RWX-RAY IN USE OR APPROVED EQUAL LED POLYCARBONATE TYPE SIGN (X-RAY IN USE). 120 V 9 WATTS Issuance Schedule Number Date Description FEC** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * * * * * * * * * * ** * * * * *** * ** ** * * ** * * EE ELEVATORELEVATORELEVATOR EXISTING EMERG MGMT STORAGE G03 EXISTING ED STORAGE G02 EXISTING OFFICE G01A EXISTING LOCKER ROOM G01 STAIR EXISTING ED LOCKER ROOM G20 EXISTING ED DR ON CALL SLEEP G19 EXISTING VEST. EXISTING EVS HSK G18 EXISTING OFFICE G17 SCOPE OF WORK EXISTING OFFICE G16 STORAGE OFFICE EXISTING ED CONF ROOM G05 EXISTING ED MEN'S LOCKER G15 EXISTING STORAGE G14 EXISTING ED ADMIN CLINICAL G13 EXTENT OF DEMO EXTENT OF DEMOEXTENT OF DEMO EXTENT OF FLOOR DEMO 5 7 8 910 1112131415 18 19 20 21 22 16 17 25 26 27 28 1 2 2 2 2 2 Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:25:48 AMFPD-101 185-01-00 8/15/16 GROUND FLOOR FIRE PROTECTION DEMOLITION PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER SCALE: 1/4" = 1'-0"1 GROUND FLOOR PLUMBING / FIRE PROTECTION DEMOLITION PLAN DEMOLITION NOTES REMOVE EXISTING SPRINKLER HEADS AND ASSOCIATED BRANCH PIPING AND MAINS. INSTALL NEW UPRIGHT HEADS FOR FULL SPRINKLER COVERAGE TROUGHOUT CONSTRUCTION. TEMPORARY HEADS AND ASSOCIATED PIPING TO BE REMOVED AFTER NEW ARE INSTALLED. PHASING TO BE COORDINATED WITH CONSTRUCTION MANAGER. EXISTING SPRINKLER HEADS IN THIS AREA TO REMAIN. 1 DEMOLITION NOTES 2 Issuance Schedule Number Date Description 5.9 5.1 AREAWAY TRANS. VAULT STORAGE ROOM CORRIDOR SOILED LINEN GENERATOR ROOM STAIRS EQUIPMENT ROOM EQUIPMENT ROOM EL. 217.9 CORR. EL. 217.9 SOILED LINEN PHYSICIST OFFICE CORRIDOR LOUNGE T.LKRS T. DARK CONTROL CORRIDORX-RAY ROOM RAD STOR CORRIDORCOMMUNICATIONS ELEV.ELEV. CLEAN PLANNING PASS. FD 4 8 10 6 1 2 1 2 3 3 4 4 4 7 6 4 6 6 6 6 6 2 10 11 2 1 32 3 2 2 1 5 4 1 2 3 4 8 9 EX. 4" S EX. 4" DCW EX. 3/4" DHWR EX. 4" DCW EX. 3" DCW EX. 2" DCW EX. 1/2" DHW EX. 2 1/2" DCW EX. 2" DCW EX. 2" DCW EX. 2" DCW EX. 1/2" DHWR EX. 1/2" DHWR EX. 1/2" DHWR EX. 2" DCW EX. 1 1/2" DHW EX. 2" DCW EX. 1 1/4" DHW EX. 2" DCW EX. 1/2" DHW EX. 2 1/2" DCW EX. 1" HW EX. 2 1/2" DCW EX. 1/2" DHWR EX. 2 1/2" DCW EX. 1" DHWR EX. 3" DHW EX. 1" EX. 1 1/4" HWR EX. 1" HWR EX. 1" HWR EX. 4" DCW EX. 1" DHWR EX. 3" DCW EX. 1" DHWR EX. 1 1/2" CW EX. 1" HW EX. 4" S 12 8 CUT AND CAP STEAM AND CONDENSATE PIPING. REMOVE STANDPIPE AND TRAP AND CAP SANITARY EXISTING COLD WATER PIPE RUNNING BETWEEN DUCTS WILL OBSTRUCT NEW DUCT, CUT AT POINTS SHOWN 13 14 15 EX. 2" V EX. 2" V 17 16 EX. MV EX. MV EX. MV EX. O2 EX. N2O MV O N2O N2O O MV S SDCW DHW DCW DHWR DCW DHWR N2ODHW DHWDCWSDCWS DHWR MVDCW S DHW DCW DCW DHWRDCWMV MV N2O O DHWS DCW DCWDCW8 9 8 Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:26:16 AMPD-100 185-01-00 8/15/16 BASEMENT PLUMBING DEMOLITION PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER SCALE: 1/4" = 1'-0"1 BASEMENT PLUMBING DEMOLITION PLAN DEMOLITION NOTES REMOVE EXISTING S, V & CW UP TO WATER CLOSET. CAP PIPING BACK AT MAINS AND/OR RISERS. REMOVE EXISTING W, HW & CW UP TO LAVATORY. CAP PIPING BACK AT MAINS AND/OR RISERS. REMOVE EXISTING S, V, HW & CW UP TO SHOWER. CAP PIPING BACK AT MAINS AND/OR RISERS. EXISTING SANITARY & HOT & COLD WATER RISERS TO REMAIN. 3" HW RISER TO REMAIN. REMOVE EXISTING W, HW & CW UP TO SINK. CAP PIPING BACK AT MAINS AND/OR RISERS. REMOVE EXISTING S, V, HW & CW UP TO MOP SINK. CAP PIPING BACK AT MAINS. EXISTING SANITARY RISER TO REMAIN. EXISTING COLD WATER RISER TO REMAIN. EXISTING TANKLESS WATER HEATER TO REMAIN. EXISTING RECIRCULATING PUMP TO REMAIN. EXISTING 4" RISE TO REMAIN REMOVE EXISTING NITROUS OXIDE FEED TO EXISTING SURGERY SUITE EXISTING NITROUS OXIDE MANIFOLD TO REMAIN EXISTING NITROUS OXIDE FEED TO MATERNITY TO REMAIN CAPPED EXISTING NITROUS OXIDE & NITROGEN FEEDS TO REMAIN. REMOVE EXISTING PORTION OF VENT PIPING THAT INTERFERES WITH NEW DUCTWORK. REROUTE AS INDICATED ON NEW PLAN. 1 2 3 4 5 6 7 8 9 10 11 DEMOLITION NOTES 12 13 14 15 16 17 Issuance Schedule Number Date Description FECELEVATORELEVATORELEVATOR EXISTING EMERG MGMT STORAGE G03 EXISTING ED STORAGE G02 EXISTING OFFICE G01A EXISTING LOCKER ROOM G01 STAIR EXISTING ED LOCKER ROOM G20 EXISTING ED DR ON CALL SLEEP G19 EXISTING VEST. EXISTING EVS HSK G18 EXISTING OFFICE G17 SCOPE OF WORK EXISTING OFFICE G16 STORAGE OFFICE EXISTING ED CONF ROOM G05 EXISTING ED MEN'S LOCKER G15 EXISTING STORAGE G14 EXISTING ED ADMIN CLINICAL G13 EXTENT OF DEMO EXTENT OF DEMOEXTENT OF DEMO EXTENT OF FLOOR DEMO 5 7 8 910 1112131415 18 19 20 21 22 16 17 25 26 27 28 6 9 4 6 12 12 3 3 6 6 610 4 9 4 4 4 4 2 2 1 32 2 2 1 6 1 2 9 6 8 3 3 4 97 5 5 5 5 69 7 6 6 9 5 11 11 9 9 9 7 12 6 8 7 13 Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:26:18 AMPD-101 185-01-00 8/15/16 GROUND FLOOR PLUMBING / FIRE PROTECTION DEMOLITION PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER SCALE: 1/4" = 1'-0"1 GROUND FLOOR PLUMBING / FIRE PROTECTION DEMOLITION PLAN DEMOLITION NOTES DISCONNECT & REMOVE EXISTING WATER CLOSET & ALL ASSOCIATED PIPING. CAP SANITARY & COLD WATER PIPING BACK AT MAINS IN BASEMENT. CAP VENT PIPING AT VENT RISER. DISCONNECT & REMOVE EXISTING LAVATORY & ALL ASSOCIATED PIPING. CAP SANITARY, HOT & COLD WATER PIPING BACK AT MAINS IN BASEMENT. CAP VENT PIPING AT VENT RISER. DISCONNECT & REMOVE EXISTING SHOWER & ALL ASSOCIATED PIPING. CAP SANITARY, HOT & COLD WATER PIPING BACK AT MAINS IN BASEMENT. CAP VENT PIPING AT VENT RISER. DISCONNECT & REMOVE EXISTING SINK & ALL ASSOCIATED PIPING. CAP SANITARY, HOT & COLD WATER PIPING BACK AT MAINS IN BASEMENT. CAP VENT PIPING AT VENT RISER. DISCONNECT & REMOVE ALL EXISTING VENT PIPING MADE OBSOLETE BY NEW CONTRUCTION BACK AT VENT RISER. EXISTING SANITARY RISER TO REMAIN. EXISTING VENT RISER TO REMAIN. EXISTING COLD WATER RISER TO REMAIN. EXISTING HOT & COLD WTER RISERS TO REMAIN. DISCONNECT & REMOVE EXISTING MOP SINK & ALL ASSOCIATED PIPING. CAP SANITARY, HOT & COLD WATER PIPING BACK AT MAINS IN BASEMENT. CAP VENT PIPING AT VENT RISER. DISCONNECT EXISTING VENT PIPING AND VENT PIPE UP. EXISTING 3" HW RISER TO REMAIN DISCONNECT & REMOVE ALL EXISTING PLUMBING ASSOCIATED WITH STERILIZER. CAP SANITARY, HOT & COLD WATER PIPING BACK AT MAINS IN BASEMENT. CAP VENT PIPING AT VENT RISER. 1 2 3 4 5 6 7 8 9 10 11 DEMOLITION NOTES 12 13 Issuance Schedule Number Date Description FECELEVATORELEVATORELEVATOR EXISTING EMERG MGMT STORAGE G03 EXISTING ED STORAGE G02 EXISTING OFFICE G01A EXISTING LOCKER ROOM G01 STAIR EXISTING ED LOCKER ROOM G20 EXISTING ED DR ON CALL SLEEP G19 EXISTING VEST. EXISTING EVS HSK G18 EXISTING OFFICE G17 SCOPE OF WORK EXISTING OFFICE G16 STORAGE OFFICE EXISTING ED CONF ROOM G05 EXISTING ED MEN'S LOCKER G15 EXISTING STORAGE G14 EXISTING ED ADMIN CLINICAL G13 EXTENT OF DEMO EXTENT OF DEMOEXTENT OF DEMO EXTENT OF FLOOR DEMO 5 7 8 910 1112131415 18 19 20 21 22 16 17 25 26 27 28 1 3 4 56 7 12 8 8 23 23 9 10 12 12 12 8 11 11 2 3 8 23 2 3 13 23 2 Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:26:14 AMMGD-101 185-01-00 8/15/16 GROUND FLOOR MEDICAL GAS DEMOLITION PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER SCALE: 1/4" = 1'-0"1 GROUND FLOOR MEDICAL GAS DEMOLITION PLAN DEMOLITION NOTES DISCONNECT & REMOVE EXISTING MED VAC ZONE CONTROL VALVE AND ALL ASSOCIATED PIPING. CAP PIPING BACK AT RISER AND MAIN. DISCONNECT & REMOVE EXISTING OXYGEN ZONE CONTROL VALVE AND ALL ASSOCIATED PIPING. CAP PIPING BACK AT RISER AND MAIN. DISCONNECT & REMOVE EXISTING NITROUS OXIDE ZONE CONTROL VALVE AND ALL ASSOCIATED PIPING. CAP PIPING BACK AT RISER AND MAIN. DISCONNECT & REMOVE EXISTING EMERGENCY SHUT-OFF VALVE AND OXYGEN ALARM PANEL AND ALL ASSOCIATED PIPING, WIRING AND ACCESSORIES. SEE MED GAS PIPING GENERAL NOTES FOR MAINTAINING EXISTING SERVICE TO UPPER FLOORS. EXISTING MED VAC RISER TO REMAIN. EXISTING OXYGEN RISER TO REMAIN. EXISTING NITROUS OXIDE RISER TO REMAIN. DISCONNECT & REMOVE EXISTING O2, N2O & MV OUTLETS AND ALL ASSOCIATED PIPING. CUT & CAP GROUND FLOOR OXYGEN & MED VAC FEED MAINS AT RISERS AS INDICATED. SEE MEDICAL GAS GENERAL NOTES ON THIS DWG. CUT & CAP GROUND FLOOR NITROUS OXIDE FEED MAINS AT RISERS AS INDICATED. SEE MEDICAL GAS GENERAL NOTES ON THIS DWG. CAP EXISTING MAINS TO BE ABANDON IN PLACE HERE. ALL CONNECTED VALVES & OUTLETS TO THE SYSTEM SHOULD BE MARKED "NOT IN SERVICE". DISCONNECT & REMOVE EXISTING MV OUTLETS AND ALL ASSOCIATED PIPING. REMOVE EXISTING MED GAS PIPING THAT WAS MADE OBSOLETE BY PREVIOUS CONSTRUCTION. MED GAS OUTLETS HAVE ALREADY BEEN CAPPED AND BLANKED OFF. REMOVE ALL PIPING BACK TO ZONE VALVES. 1 2 1. REMOVAL OF THE EXISTING MEDICAL GAS PIPING ON THIS FLOOR WILL REQUIRE A COMPLETE SHUTDOWN OF THE ENTIRE MV, O2, AND N2O RISERS AS THERE ARE NO SERVICE VALVES AT THIS FLOOR LEVEL. 2. TEMPORARY MV, O2, AND N2O EQUIPMENT WILL BE REQUIRED FOR PATIENT USE DURING THE SHUTDOWN PERIOD. 3. SYSTEM SHUTDOWN AND TEMP MV, O2, AND N20 EQUIPMENT REQUIREMENTS SHALL BE COORDINATED WITH THE HOSPITAL FACILITIES ENGINEERING PERSONNEL AND HOSPITAL STAFF ON FLOOR LEVELS AFFECTED BY THIS SHUTDOWN PRIOR TO THE START OF ANY WORK. MED GAS PIPING GENERAL NOTES 3 4 5 6 7 8 9 10 11 12 DEMOLITION NOTESMED GAS PIPING GENERAL NOTES 13 Issuance Schedule Number Date Description 1 2016.07.08 ADDENDUM #1 FECEE SD DS M SCOPE OF WORK RADIOLOGIST WORKROOM G-124 ULTRASOUND EQUIPMENT TASK CHAIR (EXISTING) STRETCHER STRETCHER BIOPSY TABLE SUCTION DEVICE STERILE SUPPLY CART RED BOX BLACK BOX GUEST CHAIR STEREO MONITOR STAND SOILED LINEN HAMPER SOILED LINEN HAMPER GUEST CHAIR SHARPS EXAM TABLE SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR REFRIDGERATOR SHARPS SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR SHARPS GLOVES AQUISITION WORKSTATION WHEELCHAIR RED BOX WALL MOUNTED PADDLES SET UP TRAY SUCTION DEVICE C-ARMSOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR 5 MP MONITOR STAND FROM STEREOTATIC LARGE MAMMOGRAPHY G-120 AQUISITION WORKSTATION WHEELCHAIR SET UP TRAY SUCTION DEVICE C-ARM CLEAN WORK AREA G-126A INTERVIEW 2 G-117 PATIENT CHANGING ROOM 3 G-111C TASK CHAIR TASK CHAIRWALL MOUNTED PADDLES LARGE BIOPSY CHAIR PATIENT CHANGING ROOM 1 G-111D PATIENT CHANGING ROOM 2 G-111B STAFF TOILET G-130A TASK CHAIR EXAM 2 G-107 EXAM TABLE SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A TASK CHAIR BONE DENSITY G-113 GOWNED SUB-WAITING G-110 SOILED LINEN HAMPER TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR PRINTER FILM COPIER PRINTER TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR (EXISTING) BONE DENSITY TABLE BONE DENSITY WORKSTATION/CART WHEELCHAIR SCALE SOILED LINEN HAMPER GUEST CHAIR TASK CHAIR (EXISTING) STADIOMETER GLOVES PRINTER, SM SOAP PAPER TOILET PAPER SOAP PAPER TOILET PAPER PAPER SOAP SOILED LINEN BINTOILET PAPER TOILET PAPER COAT HOOKS CODE CART METRO RACK TRAY RACK 5 MP MONITOR STAND STEREO GENERATOR MIRCROWAVE KEURIG PURELL PURELL PURELL PURELL PURELL PURELL PURELLPURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL RED BOX SHARPS SHARPS TASK CHAIR (EXISTING) PURELL PURELL PURELLPURELL TASK CHAIR TASK CHAIR WITHOUT ARMS BACKERBOARD METRO RACK WOW TRASH STANDING WATER COOLER RECYCLE CONFIDENTIAL RECYCLE MOBILE PED MOBILE PED RADIOLOGIST WORKSTATION (EXISTING) RADIOLOGIST WORKSTATION (EXISTING) PHONE PHONE SIDE TABLE - SMALL TASK CHAIR WITHOUT ARMS STRETCHER ROUND TABLE WITH 4 CHAIRS LOUNGE CHAIR SCANNER SCANNER DESK DESK LOUNGE CHAIR PURELL INTERVIEW 1 G-118 ICE PAPER SOAP TRASH DEFIBRILLATOR SOAP PAPER PRINTER, SM TASK CHAIR STAFF BREAK ROOM G-123 CORRIDOR G-128 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B STRETCHER WAITING G-127 NURSE STATION G-126 ELECTRICAL CLOSET G-125 WAITING ROOM G-119 RECEPTION G-114C CORRIDOR G-119B WAITING ROOM PATIENT TOILET G-119A MEN'S CHANGING & WAITING G-114 PATIENT TOILET G-109 CORRIDOR G-115D CORRIDOR G-115C STEREOTACTIC G-105 NAVIGATOR'S OFFICE G-116 ULTRASOUND G-121MAMMOGRAPHY G-122 EXAM 1 G-106 COPIER RECYCLE WASTEBASKET PURELL SIDE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR WHEELCHAIR TRASH SOAP LOUNGE CHAIR LOUNGE CHAIR WATER LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE SETTEE COFFEE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE MOBILE PED BLACK BOX MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED TASK CHAIR WASTEBASKET RECYCLE TRASH RECYCLE WASTEBASKET SOILED LINEN HAMPER TRASH PAPER SOAP PAPER TRASH SOAP TRASH PHONE PAPER SOAP COAT HOOKS VIEW BOX TRASH PAPER SOAP PHONE PURELL PAPER SOAP PHONE PHONE WASTEBASKET RECYCLE SHARPS SHARPS SHARPS PHONE PHONE GLOVES GLOVESGLOVES PHONE PURELL SOAPPAPER TRASH WASTEBASKET RECYCLE SOAP PAPER PAPER SOAP PAPERSOAP TRASH GLOVESGLOVES SOAP PAPER PAPER PAPER SOAP PHONE TRASH TRASH PHONE COMPUTER COMPUTER PHONE PHONESHARPS SHARPS PHONE COMPUTER COMPUTER SOAP MIRROR, TALL MIRROR, TALL MIRROR, TALL MIRROR, TALL PAPER WATER TRASH TRASH WASTEBASKET PHONE COMPUTER COMPUTER PHONE WASTEBASKET COMPUTER PHONE PHONE TRASH WASTEBASKET RECYCLE RECYCLE RECYCLE TRASH TRASH TRASH COAT HOOKS TRASH UC FRIDGE PHONE COMPUTER STABLERISE STABLERISE SCANNER SCANNER SCANNER CPU CPU CPU SCANNER SCANNER SCANNER CPU CPU CPU OFFICE G-108 CPU CPU 5 7 8 910 1112131415 18 19 20 21 22 16 17 25 26 27 28 Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:25:46 AMFP-101 185-01-00 8/15/16 GROUND FLOOR FIRE PROTECTION PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER DRAWING NOTES INSTALL NEW CONCEALED PENDENT QUICK RESPONSE SPRINKLER HEADS WITHIN THE OUTLINED AREA. CONNECT NEW SPRINKLER DROPS TO EXISTING CAPPED DROPS PROVIDED UNDER THE DEMOLITION SCOPE OF WORK. REFER TO THE GENERAL FIRE PROTECTION NOTES ON THIS DRAWING FOR ADDITIONAL FIRE PROTECTION REQUIREMENTS. 1 2 SCALE: 1/4" = 1'-0"1 GROUND FLOOR FIRE PROTECTION PLAN 1. THIS DRAWING DEPICTS A PROPOSED FIRE PROTECTION SYSTEM LAYOUT WHICH IS INDICATED FOR COORDINATION PURPOSES ONLY. THIS DOES NOT RELIEVE THE CONTRACTOR FROM COMPLYING WITH NFPA, STATE, & LOCAL CODES, THE OWNER'S INSURANCE COMPANY, AND THE AUTHORITY HAVING JURISDICTION. 2. REFER TO THE FIRE PROTECTION SPECIFICATIONS FOR DESIGN CRITERIA AND INSTALLATION REQUIREMENTS. 3. FIRE PROTECTION SYSTEM CONTRACTOR SHALL COORDINATE LOCATIONS OF SPRINKLERS AND PIPING WITH HVAC DUCTS, EQUIPMENT, BEAMS, COLUMNS, LIGHTS, AND ANY OTHER OBSTRUCTIONS IN ACCORDANCE WITH NFPA. 4. THIS CONTRACT INCLUDES A PERFORMANCE SPECIFICATION FOR THE ENTIRE FIRE PROTECTION SYSTEM. 5. PROVIDE ALL PIPING, SUPPORTS, AND EQUIPMENT FOR A COMPLETE FULL COVERAGE SYSTEM IN CONFORMANCE WITH NFPA, STATE & LOCAL CODES, THE OWNER'S INSURANCE COMPANY, AND THE AUTHORITY HAVING JURISDICTION. ADVISE ARCHITECT OF ANY CONFLICTS WHICH MUST BE RESOLVED PRIOR TO INSTALLATION. 6. PROVIDE CHROME PLATED ESCUTCHEONS AT EXPOSED PIPING PENETRATIONS OF WALLS, CEILINGS, AND FLOORS. 7. ALL NEW SPRINKLER HEADS SHALL BE OF QUICK RESPONSE TYPE WITH TEMPERATURE RATING BASED ON AMBIENT TEMPERATURE CONDITIONS FOR EACH PROTECTED SPACE. 8. USE UPRIGHT SPRINKLER HEADS IN AREAS WITHOUT CEILINGS AND WHERE SPRINKLER PIPING MUST BE RUN EXPOSED. USE CONCEALED PENDENT SPRINKLER HEADS IN AREAS WITH FINISHED AND/OR ACCESSIBLE CEILINGS. 9. ALL SPK VALVES SHALL BE LABELED TO IDENTIFY WHAT AREAS THEY CONTROL. 10. PIPE SIZES SHOWN ON THE PLANS ARE APPROXIMATE AND CAN BE INCREASED OR DECREASED BASED ON FINAL HYDRAULIC CALCULATIONS PERFORMED BY THE CONTRACTOR. ALL PIPE SIZES SHALL BE IN ACCORDANCE WITH NFPA AND INSURANCE UNDERWRITER. 11. FIRE PROTECTION HAZARD CLASSIFICATION AND DESIGN CRITERIA SHALL BE AS FOLLOWS: A. SOILED UTILITY & STORAGE ROOMS: ORDINARY HAZARD GROUP 1, DESIGN AREA = ENTIRE SPACE, DENSITY = 0.15 GPM/SF, HEAD SPACING = 130 SF, INSIDE/OUTSIDE HOSE = 250 GPM B. REMAINDER OF FINISHED OCCUPIED SPACES: LIGHT HAZARD, DESIGN AREA = 1500 SF, DENSITY = 0.10 GPM/SF, HEAD SPACING = 168 SF, INSIDE/OUTSIDE HOSE = 100 GPM 12. COORDINATE ANY NECESSARYSLEEVES FOR PIPING PASSING THRU LEAD-LINED WALLS WITH INSTALLER. GENERAL FIRE PROTECTION NOTES DRAWING NOTESGENERAL FIRE PROTECTION NOTES Issuance Schedule Number Date Description 1 2016.07.08 ADDENDUM #1 5.9 5.1 AREAWAY TRANS. VAULT STORAGE ROOM CORRIDOR SOILED LINEN GENERATOR ROOM STAIRS EQUIPMENT ROOM EQUIPMENT ROOM EL. 217.9 CORR. EL. 217.9 SOILED LINEN PHYSICIST OFFICE CORRIDOR LOUNGE T.LKRS T. DARK CONTROL CORRIDORX-RAY ROOM RAD STOR CORRIDORCOMMUNICATIONS ELEV.ELEV. CLEAN PLANNING PASS. FD DS 1 4" S 11 8 C.O. C.O. C.O. C.O. C.O. C.O. 8 3" W 2 3" W 2" W 3" W 2" W 2" W 8 8 C.O. 8 8 7 8 8 8 3 3 2" W 2" W 8 7 7 9 9 8 9 C.O. 10 4 5 6 2" W 4" S 1 1/4" DHW 2" W 4" S 2" W 8 2" W EXTEND NEW COLD WATER PIPING AROUND NEW SUPPLY DUCT RISER C.O. 12 13 14 15 EX. 4" DCW EX. 3/4" DHWR EX. 4" DCW EX. 3" DCW EX. 2" DCW EX. 1/2" DHW EX. 2 1/2" DCW EX. 2" DCW EX. 2" DCW EX. 2" DCW EX. 1/2" DHWR EX. 1/2" DHWR EX. 1/2" DHWR EX. 2" DCW EX. 1 1/2" DHW EX. 2" DCW EX. 1 1/4" DHW EX. 2" DCW EX. 1/2" DHW EX. 2 1/2" DCW EX. 1" HW EX. 2 1/2" DCW EX. 1/2" DHWR EX. 2 1/2" DCW EX. 1" DHWR EX. 3" DHW EX. 1" EX. 1 1/4" HWR EX. 1" HWR EX. 1" HWR EX. 4" DCW EX. 1" DHWR EX. 3" DCW EX. 1" DHWR EX. 4" S EX. 2" V EX. 2" V EX. MV EX. MV EX. MV EX. O2 EX. N2O 9 MV O N2O DHWRDHWDCW DHWR MV O N2O DCW DHWR N2O SSW W8 DHWRDCWS WDCW DCW W WDCWDHWRN2OW MVMVVV W WSS WDHW 1 16 1 C.O. C.O. C.O.SS W DHWC.O. 2 H-100 2" W 8 2" W 4" S 4" S 4" S 2" W 4" S 3" W 77 2" W 2" W 2" W C.O. 2" W Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:26:19 AMPS-100 185-01-00 8/15/16 BASEMENT PLUMBING PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER DRAWING NOTES CONNECT NEW 4" S TO EXISTING STACK HERE CONNECT NEW 3" W TO EXISTING STACK HERE CONNECT NEW 2" W TO EXISTING STACK HERE CONNECT NEW 1 1/4" HW TO EXISTING 3" HERE CONNECT NEW 2" CW TO EXISTING 2 1/2" HERE CONNECT NEW 3/4" HWR TO EXISTING 1" HERE CONNECT NEW CW TO EXISTING HERE 2" W UP 4" S UP 1 1/4" HW, 2" CW & 3/4" HWR UP CONNECT NEW 3" W TO EXISTING 4" RISE HERE CONNECT NEW 3/4" N2O TO EXISTING 3/4" HERE CONNECT NEW 3/4" N2O TO EXISTING 3/4" HERE WITH NEW VALVE - NORMALLY CLOSED. SEE DETAIL ON DRAWING P400 FOR CONNECTIONS TO EXISTING MANIFOLD. EXISTING N2O MANIFOLD TO REMAIN EXISTING 1/2" N2O TO MATERNITY TO REMAIN 2" V UP 1 2 SCALE: 1/4" = 1'-0"1 BASEMENT PLUMBING PLAN DRAWING NOTES 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Issuance Schedule Number Date Description FECSD DS M SCOPE OF WORK RADIOLOGIST WORKROOM G-124 ULTRASOUND EQUIPMENT TASK CHAIR (EXISTING) STRETCHER STRETCHER BIOPSY TABLE SUCTION DEVICE STERILE SUPPLY CART RED BOX BLACK BOX GUEST CHAIR STEREO MONITOR STAND SOILED LINEN HAMPER SOILED LINEN HAMPER GUEST CHAIR SHARPS EXAM TABLE SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR REFRIDGERATOR SHARPS SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR SHARPS GLOVES AQUISITION WORKSTATION WHEELCHAIR RED BOX WALL MOUNTED PADDLES SET UP TRAY SUCTION DEVICE C-ARMSOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR 5 MP MONITOR STAND FROM STEREOTATIC LARGE MAMMOGRAPHY G-120 AQUISITION WORKSTATION WHEELCHAIR SET UP TRAY SUCTION DEVICE C-ARM CLEAN WORK AREA G-126A INTERVIEW 2 G-117 PATIENT CHANGING ROOM 3 G-111C TASK CHAIR TASK CHAIRWALL MOUNTED PADDLES LARGE BIOPSY CHAIR PATIENT CHANGING ROOM 1 G-111D PATIENT CHANGING ROOM 2 G-111B STAFF TOILET G-130A TASK CHAIR EXAM 2 G-107 EXAM TABLE SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A TASK CHAIR BONE DENSITY G-113 GOWNED SUB-WAITING G-110 SOILED LINEN HAMPER TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR PRINTER FILM COPIER PRINTER TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR (EXISTING) BONE DENSITY TABLE BONE DENSITY WORKSTATION/CART WHEELCHAIR SCALE SOILED LINEN HAMPER GUEST CHAIR TASK CHAIR (EXISTING) STADIOMETER GLOVES PRINTER, SM SOAP PAPER TOILET PAPER SOAP PAPER TOILET PAPER PAPER SOAP SOILED LINEN BINTOILET PAPER TOILET PAPER COAT HOOKS CODE CART METRO RACK TRAY RACK 5 MP MONITOR STAND STEREO GENERATOR MIRCROWAVE KEURIG PURELL PURELL PURELL PURELL PURELL PURELL PURELLPURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL RED BOX SHARPS SHARPS TASK CHAIR (EXISTING) PURELL PURELL PURELLPURELL TASK CHAIR TASK CHAIR WITHOUT ARMS BACKERBOARD METRO RACK WOW TRASH STANDING WATER COOLER RECYCLE CONFIDENTIAL RECYCLE MOBILE PED MOBILE PED RADIOLOGIST WORKSTATION (EXISTING) RADIOLOGIST WORKSTATION (EXISTING) PHONE PHONE SIDE TABLE - SMALL TASK CHAIR WITHOUT ARMS STRETCHER ROUND TABLE WITH 4 CHAIRS LOUNGE CHAIR SCANNER SCANNER DESK DESK LOUNGE CHAIR PURELL INTERVIEW 1 G-118 ICE PAPER SOAP TRASH DEFIBRILLATOR SOAP PAPER PRINTER, SM TASK CHAIR STAFF BREAK ROOM G-123 CORRIDOR G-128 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B STRETCHER WAITING G-127 NURSE STATION G-126 ELECTRICAL CLOSET G-125 WAITING ROOM G-119 RECEPTION G-114C CORRIDOR G-119B WAITING ROOM PATIENT TOILET G-119A MEN'S CHANGING & WAITING G-114 PATIENT TOILET G-109 CORRIDOR G-115D CORRIDOR G-115C STEREOTACTIC G-105 NAVIGATOR'S OFFICE G-116 ULTRASOUND G-121MAMMOGRAPHY G-122 EXAM 1 G-106 COPIER RECYCLE WASTEBASKET PURELL SIDE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR WHEELCHAIR TRASH SOAP LOUNGE CHAIR LOUNGE CHAIR WATER LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE SETTEE COFFEE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE MOBILE PED BLACK BOX MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED TASK CHAIR WASTEBASKET RECYCLE TRASH RECYCLE WASTEBASKET SOILED LINEN HAMPER TRASH PAPER SOAP PAPER TRASH SOAP TRASH PHONE PAPER SOAP COAT HOOKS VIEW BOX TRASH PAPER SOAP PHONE PURELL PAPER SOAP PHONE PHONE WASTEBASKET RECYCLE SHARPS SHARPS SHARPS PHONE PHONE GLOVES GLOVESGLOVES PHONE PURELL SOAPPAPER TRASH WASTEBASKET RECYCLE SOAP PAPER PAPER SOAP PAPERSOAP TRASH GLOVESGLOVES SOAP PAPER PAPER PAPER SOAP PHONE TRASH TRASH PHONE COMPUTER COMPUTER PHONE PHONESHARPS SHARPS PHONE COMPUTER COMPUTER SOAP MIRROR, TALL MIRROR, TALL MIRROR, TALL MIRROR, TALL PAPER WATER TRASH TRASH WASTEBASKET PHONE COMPUTER COMPUTER PHONE WASTEBASKET COMPUTER PHONE PHONE TRASH WASTEBASKET RECYCLE RECYCLE RECYCLE TRASH TRASH TRASH COAT HOOKS TRASH UC FRIDGE PHONE COMPUTER STABLERISE STABLERISE SCANNER SCANNER SCANNER CPU CPU CPU SCANNER SCANNER SCANNER CPU CPU CPU OFFICE G-108 CPU CPU 5 7 8 910 1112131415 18 19 20 21 22 16 17 25 26 27 28 SK-1 SK-3 SK-1 SK-3 SK-1 SK-1 SK-1 SK-1 SK-1 SK-1 LAV-1 WC-1 LAV-1 LAV-1 WC-1 WC-3 SK-2 LAV-1 WC-2 SK-1 5 5 5 5 3 3 2 1 3 3 3 2 1 2 3 3 1 2 5 3 3 3 2" V 1 1/2" V 2" V 2" V 2" V 2" V SK-1 3 2" V 2" V 2" V 2" V 2" V 2" V 2" V 3 8 9 10 2 H-100 SK-1 WB-1 11 C.O.ACCESS PANEL 2" V 2" V Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:26:22 AMPS-101 185-01-00 8/15/16 GROUND FLOOR PLUMBING SANITARY AND VENT PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER DRAWING NOTES 4" S DN; 2" V RISE - FINAL CONNECT TO WATER CLOSET 2" W DN; 2" V ROSE - FINAL CONNECT TO LAVATORY 2" W DN; 2" V RISE - FINAL CONNECT TO SINK 2" W DN; 2" V RISE - FINAL CONNECT W&V TO EACH SINK CONNECT NEW 2" V TO EXISTING STACK HERE NOT USED NOT USED CONNECT EXISTING VENT FROM MOP SINK TO NEW VENT IN PLUMBING CHASE 2" V DN; 2" V RISE 2" W DN - RUN IN WALL TO SINK 2" W DN & 2" V RISE - FINAL CONNECT TO ICE MACHINE WATER- DRAIN BOX (WB-1) WITH 2" TRAP. 1 2 SCALE: 1/4" = 1'-0"1 GROUND FLOOR PLUMBING SANITARY AND VENT PLAN DRAWING NOTES 3 4 5 6 7 8 9 10 11 Issuance Schedule Number Date Description FECSD DS M SCOPE OF WORK RADIOLOGIST WORKROOM G-124 ULTRASOUND EQUIPMENT TASK CHAIR (EXISTING) STRETCHER STRETCHER BIOPSY TABLE SUCTION DEVICE STERILE SUPPLY CART RED BOX BLACK BOX GUEST CHAIR STEREO MONITOR STAND SOILED LINEN HAMPER SOILED LINEN HAMPER GUEST CHAIR SHARPS EXAM TABLE SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR REFRIDGERATOR SHARPS SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR SHARPS GLOVES AQUISITION WORKSTATION WHEELCHAIR RED BOX WALL MOUNTED PADDLES SET UP TRAY SUCTION DEVICE C-ARMSOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR 5 MP MONITOR STAND FROM STEREOTATIC LARGE MAMMOGRAPHY G-120 AQUISITION WORKSTATION WHEELCHAIR SET UP TRAY SUCTION DEVICE C-ARM CLEAN WORK AREA G-126A INTERVIEW 2 G-117 PATIENT CHANGING ROOM 3 G-111C TASK CHAIR TASK CHAIRWALL MOUNTED PADDLES LARGE BIOPSY CHAIR PATIENT CHANGING ROOM 1 G-111D PATIENT CHANGING ROOM 2 G-111B STAFF TOILET G-130A TASK CHAIR EXAM 2 G-107 EXAM TABLE SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A TASK CHAIR BONE DENSITY G-113 GOWNED SUB-WAITING G-110 SOILED LINEN HAMPER TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR PRINTER FILM COPIER PRINTER TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR (EXISTING) BONE DENSITY TABLE BONE DENSITY WORKSTATION/CART WHEELCHAIR SCALE SOILED LINEN HAMPER GUEST CHAIR TASK CHAIR (EXISTING) STADIOMETER GLOVES PRINTER, SM SOAP PAPER TOILET PAPER SOAP PAPER TOILET PAPER PAPER SOAP SOILED LINEN BINTOILET PAPER TOILET PAPER COAT HOOKS CODE CART METRO RACK TRAY RACK 5 MP MONITOR STAND STEREO GENERATOR MIRCROWAVE KEURIG PURELL PURELL PURELL PURELL PURELL PURELL PURELLPURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL RED BOX SHARPS SHARPS TASK CHAIR (EXISTING) PURELL PURELL PURELLPURELL TASK CHAIR TASK CHAIR WITHOUT ARMS BACKERBOARD METRO RACK WOW TRASH STANDING WATER COOLER RECYCLE CONFIDENTIAL RECYCLE MOBILE PED MOBILE PED RADIOLOGIST WORKSTATION (EXISTING) RADIOLOGIST WORKSTATION (EXISTING) PHONE PHONE SIDE TABLE - SMALL TASK CHAIR WITHOUT ARMS STRETCHER ROUND TABLE WITH 4 CHAIRS LOUNGE CHAIR SCANNER SCANNER DESK DESK LOUNGE CHAIR PURELL INTERVIEW 1 G-118 ICE PAPER SOAP TRASH DEFIBRILLATOR SOAP PAPER PRINTER, SM TASK CHAIR STAFF BREAK ROOM G-123 CORRIDOR G-128 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B STRETCHER WAITING G-127 NURSE STATION G-126 ELECTRICAL CLOSET G-125 WAITING ROOM G-119 RECEPTION G-114C CORRIDOR G-119B WAITING ROOM PATIENT TOILET G-119A MEN'S CHANGING & WAITING G-114 PATIENT TOILET G-109 CORRIDOR G-115D CORRIDOR G-115C STEREOTACTIC G-105 NAVIGATOR'S OFFICE G-116 ULTRASOUND G-121MAMMOGRAPHY G-122 EXAM 1 G-106 COPIER RECYCLE WASTEBASKET PURELL SIDE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR WHEELCHAIR TRASH SOAP LOUNGE CHAIR LOUNGE CHAIR WATER LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE SETTEE COFFEE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE MOBILE PED BLACK BOX MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED TASK CHAIR WASTEBASKET RECYCLE TRASH RECYCLE WASTEBASKET SOILED LINEN HAMPER TRASH PAPER SOAP PAPER TRASH SOAP TRASH PHONE PAPER SOAP COAT HOOKS VIEW BOX TRASH PAPER SOAP PHONE PURELL PAPER SOAP PHONE PHONE WASTEBASKET RECYCLE SHARPS SHARPS SHARPS PHONE PHONE GLOVES GLOVESGLOVES PHONE PURELL SOAPPAPER TRASH WASTEBASKET RECYCLE SOAP PAPER PAPER SOAP PAPERSOAP TRASH GLOVESGLOVES SOAP PAPER PAPER PAPER SOAP PHONE TRASH TRASH PHONE COMPUTER COMPUTER PHONE PHONESHARPS SHARPS PHONE COMPUTER COMPUTER SOAP MIRROR, TALL MIRROR, TALL MIRROR, TALL MIRROR, TALL PAPER WATER TRASH TRASH WASTEBASKET PHONE COMPUTER COMPUTER PHONE WASTEBASKET COMPUTER PHONE PHONE TRASH WASTEBASKET RECYCLE RECYCLE RECYCLE TRASH TRASH TRASH COAT HOOKS TRASH UC FRIDGE PHONE COMPUTER STABLERISE STABLERISE SCANNER SCANNER SCANNER CPU CPU CPU SCANNER SCANNER SCANNER CPU CPU CPU OFFICE G-108 CPU CPU 5 7 8 910 1112131415 18 19 20 21 22 16 17 25 26 27 28 SK-1 SK-3 SK-1 SK-1 SK-1 SK-1 SK-1 SK-1 SK-1 SK-1 SK-1 LAV-1 WC-1 LAV-1 LAV-1 WC-1 WC-3 SK-2 LAV-2 WC-2 1 4 5 3 2 3/4" DHWR 1 1/2" DHW 2" DCW 7 7 7 6 3 3 6 7 3 6 3 8 7 7 8 2" DCW 1 1/2" DHW 1/2" DHW 1/2" DCW 1/2" DHW 1/2" DCW 1/2" DHW 1/2" DCW 2" DCW 1 1/4" DHW1 1/4" DHW 2" DCW 2" DCW1 1/4" DHW 2" DCW 1 1/4" DHW 1 1/4" DHW 2" DCW 1/2" DHW 1/2" DCW 3/4" DHWR 1/2" DHW 1/2" DCW 1" DCW 1/2" DCW 1/2" DHW 1/2" DCW 1/2" DHW 1" DCW 1/2" DHW 1/2" DCW SK-1 3/4" DHW 3/4" DCW 1 1/2" DCW 1/2" DHW 1/2" DCW 1/2" DHW 1/2" DCW 7 7 7 1" DHW1" DCW 3/4" DCW 3/4" DHW SK-1 9 7 9 9 10 WB-1 1" DCW 1" DHW 3/4" DHWR 11 12 Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:26:26 AMPW-101 185-01-00 8/15/16 GROUND FLOOR PLUMBING DOMESTIC WATER PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER DRAWING NOTES 1 1/2" HW, 2" CW & 3/4" HWR DROPS WITH SHUT OFF VALVES EXTEND 1 1/4" CW & 1/2" HW IN CHASE FOR FINAL CONNECTION TO WATER CLOSET & LAVATORY 1/2" H&CW DROP - FINAL CONNECT TO LAVATORY 1" CW DROP - FINALL CONNECT TO WATER CLOSET SHOCK ABSORBER (SA-1) AT ACCESS PANEL 1" CW DROP w/ SHOCK ABSORBER (SA-2) AT ACCESS PANEL - FINAL CONNECT TO WATER CLOSET. 1/2" H&CW DROP - FINAL CONNECT TO SINK 1/2" H&CW DROP - FINAL CONNECT TO EACH SINK 1/2" CW DROP WITH ANGLE STOP FOR CONNECTION TO WATER COOLER. PROVIDE WATER FILTER: AQUAPURE MODEL #BREW110-MS WITH SPARE CARTRIDGE #HF10-MS. 1/2" CW DROP TO ICE MACHINE WATER-DRAIN BOX (WB-1). PROVIDE WITH WATTS #9D DUAL CHECK VALVE ON CONNECTION TO ICE MACHINE. PIPE RELIEF VENT TO DRAIN IN WB-1. PROVIDE WATER FILTER: AQUAPURE MODEL #ICE120-S WITH SPARE CARTRIDGE #HF20-S. 1 1/2" CW, 1" HW & 3/4" HWR VALVED AND CAPPED FOR FUTURE THIS VALVE TO BE CLOSED UNTIL FUTURE. 1 2 SCALE: 1/4" = 1'-0"1 GROUND FLOOR PLUMBING DOMESTIC WATER PLAN 3 4 5 6 7 8 9 10 11 12 Issuance Schedule Number Date Description FECOVSOVSSCOPE OF WORK RADIOLOGIST WORKROOM G-124 ULTRASOUND EQUIPMENT TASK CHAIR (EXISTING) STRETCHER STRETCHER BIOPSY TABLE SUCTION DEVICE STERILE SUPPLY CART RED BOX BLACK BOX GUEST CHAIR STEREO MONITOR STAND SOILED LINEN HAMPER SOILED LINEN HAMPER GUEST CHAIR SHARPS EXAM TABLE SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR REFRIDGERATOR SHARPS SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR SHARPS GLOVES AQUISITION WORKSTATION WHEELCHAIR RED BOX WALL MOUNTED PADDLES SET UP TRAY SUCTION DEVICE C-ARMSOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR 5 MP MONITOR STAND FROM STEREOTATIC LARGE MAMMOGRAPHY G-120 AQUISITION WORKSTATION WHEELCHAIR SET UP TRAY SUCTION DEVICE C-ARM CLEAN WORK AREA G-126A INTERVIEW 2 G-117 PATIENT CHANGING ROOM 3 G-111C TASK CHAIR TASK CHAIRWALL MOUNTED PADDLES LARGE BIOPSY CHAIR PATIENT CHANGING ROOM 1 G-111D PATIENT CHANGING ROOM 2 G-111B STAFF TOILET G-130A TASK CHAIR EXAM 2 G-107 EXAM TABLE SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A TASK CHAIR BONE DENSITY G-113 GOWNED SUB-WAITING G-110 SOILED LINEN HAMPER TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR PRINTER FILM COPIER PRINTER TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR (EXISTING) BONE DENSITY TABLE BONE DENSITY WORKSTATION/CART WHEELCHAIR SCALE SOILED LINEN HAMPER GUEST CHAIR TASK CHAIR (EXISTING) STADIOMETER GLOVES PRINTER, SM SOAP PAPER TOILET PAPER SOAP PAPER TOILET PAPER PAPER SOAP SOILED LINEN BINTOILET PAPER TOILET PAPER COAT HOOKS CODE CART METRO RACK TRAY RACK 5 MP MONITOR STAND STEREO GENERATOR MIRCROWAVE KEURIG PURELL PURELL PURELL PURELL PURELL PURELL PURELLPURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL RED BOX SHARPS SHARPS TASK CHAIR (EXISTING) PURELL PURELL PURELLPURELL TASK CHAIR TASK CHAIR WITHOUT ARMS BACKERBOARD METRO RACK WOW TRASH STANDING WATER COOLER RECYCLE CONFIDENTIAL RECYCLE MOBILE PED MOBILE PED RADIOLOGIST WORKSTATION (EXISTING) RADIOLOGIST WORKSTATION (EXISTING) PHONE PHONE SIDE TABLE - SMALL TASK CHAIR WITHOUT ARMS STRETCHER ROUND TABLE WITH 4 CHAIRS LOUNGE CHAIR SCANNER SCANNER DESK DESK LOUNGE CHAIR PURELL INTERVIEW 1 G-118 ICE PAPER SOAP TRASH DEFIBRILLATOR SOAP PAPER PRINTER, SM TASK CHAIR STAFF BREAK ROOM G-123 CORRIDOR G-128 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B STRETCHER WAITING G-127 NURSE STATION G-126 ELECTRICAL CLOSET G-125 WAITING ROOM G-119 RECEPTION G-114C CORRIDOR G-119B WAITING ROOM PATIENT TOILET G-119A MEN'S CHANGING & WAITING G-114 PATIENT TOILET G-109 CORRIDOR G-115D CORRIDOR G-115C STEREOTACTIC G-105 NAVIGATOR'S OFFICE G-116 ULTRASOUND G-121MAMMOGRAPHY G-122 EXAM 1 G-106 COPIER RECYCLE WASTEBASKET PURELL SIDE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR WHEELCHAIR TRASH SOAP LOUNGE CHAIR LOUNGE CHAIR WATER LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE SETTEE COFFEE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE MOBILE PED BLACK BOX MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED TASK CHAIR WASTEBASKET RECYCLE TRASH RECYCLE WASTEBASKET SOILED LINEN HAMPER TRASH PAPER SOAP PAPER TRASH SOAP TRASH PHONE PAPER SOAP COAT HOOKS VIEW BOX TRASH PAPER SOAP PHONE PURELL PAPER SOAP PHONE PHONE WASTEBASKET RECYCLE SHARPS SHARPS SHARPS PHONE PHONE GLOVES GLOVESGLOVES PHONE PURELL SOAPPAPER TRASH WASTEBASKET RECYCLE SOAP PAPER PAPER SOAP PAPERSOAP TRASH GLOVESGLOVES SOAP PAPER PAPER PAPER SOAP PHONE TRASH TRASH PHONE COMPUTER COMPUTER PHONE PHONESHARPS SHARPS PHONE COMPUTER COMPUTER SOAP MIRROR, TALL MIRROR, TALL MIRROR, TALL MIRROR, TALL PAPER WATER TRASH TRASH WASTEBASKET PHONE COMPUTER COMPUTER PHONE WASTEBASKET COMPUTER PHONE PHONE TRASH WASTEBASKET RECYCLE RECYCLE RECYCLE TRASH TRASH TRASH COAT HOOKS TRASH UC FRIDGE PHONE COMPUTER STABLERISE STABLERISE SCANNER SCANNER SCANNER CPU CPU CPU SCANNER SCANNER SCANNER CPU CPU CPU OFFICE G-108 CPU CPU 5 7 8 910 1112131415 18 19 20 21 22 16 17 25 26 27 28 ZVB-1 3/4" O 3/4" MV 1/2" O 3/4" MV 1/2" O 3/4" MV 1 2 3 4 4 5 Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:26:12 AMMG-101 185-01-00 8/15/16 GROUND FLOOR MEDICAL GAS PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER DRAWING NOTES EXISTING MEDICAL VACUUM & OXYGEN RISERS TO REMAIN. EXTEND 3/4" MED VAC & OXYGEN TO HOLDING / RECOVERY ROOM. 3/4" MV & 3/4" O DROP TO ZONE VALVE BOX. 3/4" MV & 1/2" O DROP AND CONNECT TO MED GAS INLETS / OUTLETS. TIE IN LOCATION OF MED VAC & OXYGEN WITHIN THIS AREA OUTLINED. CONFIRM EXACT LOCATION WITH OWNER AND VERIFY EXACT SIZES IN FIELD. CONNECT TO EXISTING RISERS AND INSTALL NEW 3/4" MV & O SERVICE VALVES FOR THIS FLOOR. 1 2 SCALE: 1/4" = 1'-0"1 GROUND FLOOR MEDICAL GAS PLAN DRAWING NOTES 3 4 5 Issuance Schedule Number Date Description 1 2016.07.08 ADDENDUM #1 DROP NIPPLE TO ACCOMMODATE NEW CEILING ELEVATION NEW SPRINKLER BRANCH LINE SPRINKLER MAIN OR BRANCH LINE ELBOW REDUCER CEILINGCONCEALED SPRINKLER HEAD NOT TO SCALE SPRINKLER HEAD DETAILS MV02MV02PRESS GAUGE (TYP.) BALL VALVE (TYP) ZONE VALVE BOX W/SEE THRU PLASTIC COVER & PULL RING - SEE ARCH. ELEVATIONS FOR MOUNTING HEIGHT NOT TO SCALE ZONE VALVE BOX DETAIL - ALTERNATE BID #4 TO & FROM SYSTEM DISTRIBUTION MAINS TO & FROM OUTLETS/INLETSN2O EXISTING 3/4" N2O FEED FROM ER PRESSURE GAUGE NEW NITROUS OXIDE MAIN LINE SHUTOFF VALVE - NORMALLY CLOSED EXISTING NITROUS OXIDE MANIFOLD CONTROL CABINET EXISTING 3/4" N2O EXISTING CYLINDERS NOT TO SCALE NITROUS OXIDE (N2O) PIPING AT EXISTING MANIFOLD DETAIL EXISTING PRESSURE SWITCH EXISTING PRESSURE SWITCH EXISTING 1/2" N2O TO MATERNITY REMOVE EXISTING 3/4" N2O TO EXISTING SURGERY CONNECT NEW 3/4" N2O TO EXISTING CAPPED LINE Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. NOT TO SCALE 8/16/2016 11:26:15 AMP-400 185-01-00 8/15/16 PLUMBING / FIRE PROTECTION DETAILS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER Issuance Schedule Number Date Description FECELEVATORELEVATORELEVATOR EXISTING EMERG MGMT STORAGE G03 EXISTING ED STORAGE G02 EXISTING OFFICE G01A EXISTING LOCKER ROOM G01 STAIR EXISTING ED LOCKER ROOM G20 EXISTING ED DR ON CALL SLEEP G19 EXISTING VEST. EXISTING EVS HSK G18 EXISTING OFFICE G17 SCOPE OF WORK EXISTING OFFICE G16 STORAGE OFFICE EXISTING ED CONF ROOM G05 EXISTING ED MEN'S LOCKER G15 EXISTING STORAGE G14 EXISTING ED ADMIN CLINICAL G13 EXTENT OF DEMO EXTENT OF DEMOEXTENT OF DEMO EXTENT OF FLOOR DEMO 5 7 8 910 1112131415 18 19 20 21 22 16 17 25 26 27 28 1 1 1 2 (TYP.) 2 (TYP.) 2 (TYP.) 2 (TYP.) 2 (TYP.) 2 (TYP.) 2 (TYP.) 8 (TYP.) 3 REMOVE EXISTING LOW EXHAUST DROP AND CAP AND SEAL 4 8 (TYP.) 7 5 (TYP.) 5 (TYP.) 3 SCOPE 2 (TYP.) 2 (TYP.) REMOVE EXISTING LOW EXHAUST DROP AND SAVE DUCT FOR REUSE ON NEW CEILING EXHAUST GRILLE REMOVE EXISTING FROM CURRENT SPOT AND SAVE TO RELOCATE TO NEW CHASE. CUT BACK EXISTING SUPPLY TO POINT SHOWN. COORDINATE WITH CEILING SPACE BELOW IN BASEMENT STORAGE ROOM. MEASURE EXISTING AIRFLOW PRIOR TO DEMOLITION AND RESTORE UPON COMPLETION FD FD CUT BACK AND CAP AND SEAL EXISTING EXHAUST DUCT FD CUT BACK EXISTING RETURN DUCT TO POINT SHOWN, CAP AND SEAL CUT BACK EXISTING RETURN DUCT TO POINT SHOWN, CAP AND SEAL CUT BACK EXISTING SUPPLY DUCT TO POINT SHOWN, CAP AND SEAL 2 (TYP.) 8 (TYP.) 8 (TYP.) 2 8 (TYP.) 8 (TYP.) 8 (TYP.) 8 (TYP.) 6 6 6 (TYP.) 2 (TYP.) 2 (TYP.) 2 (TYP.) 8 (TYP.)6 6 6 6 2 H-100 Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:25:59 AMHD-101 185-01-00 8/15/16 GROUND FLOOR HVAC DEMOLITION PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER DEMOLITION NOTES REMOVE EXISTING LAMINAR FLOW SUPPLY DIFFUSERS. REMOVE ALL EXISTING SUPPLY DUCTWORK SHOWN DASHED AND EXISTING DIFFUSERS, HANGERS, SUPPORTS, AND DAMPERS BACK TO POINTS SHOWN. RISERS FROM BASEMENT LEVEL SUPPLYING UP TO FIRST FLOOR TO REMAIN FOR REUSE. EXISTING SUPPLY DUCT TO REMAIN. REMOVE EXISTING HAZARDOUS EXHAUST. CONTRACTOR SHALL UTILIZE CERTIFIED TESTING AND ABATEMENT CONTRACTOR FOR SAFE REMOVAL AND DISPOSAL. VERIFY IN FIELD. REMOVE ALL EXISTING RETURN DUCTWORK SHOWN DASHED AND ASSOCIATED GRILLES, HANGERS, SUPPORTS, AND DAMPERS FROM POINTS SHOWN. EXISTING RISERS UP FROM BASEMENT LEVEL TO REMAIN. EXISTING EXHAUST DUCTS TO REMAIN. REMOVE EXISTING RETURN / EXHAUST BRANCHES SHOWN DASHED AND CAP AND SEAL TAKE OFFS. REMOVE ALL EXISTING EXHAUST DUCTWORK SHOWN DASHED AND ASSOCIATED GRILLES, HANGERS, SUPPORTS, AND DAMPERS FROM POINTS SHOWN. EXISTING RISERS UP TO REMAIN. CAP AT RISERS WHERE SHOWN. 1 2 SCALE: 1/4" = 1'-0"1 GROUND FLOOR HVAC DEMOLITION PLAN GENERAL NOTES PRIOR TO DEMOLITION, MEASURE AND RECORD AIRFLOW AT EXISTING AIR HANDLING UNITS S-1 AND S-2 AND ALL EXISTING BRANCH DUCTS TO REMAIN. RESTORE AIRFLOW TO EXISTING BRANCHES UPON COMPLETION. 1. 3 4 5 6 7 DEMOLITION NOTESGENERAL NOTES 8 Issuance Schedule Number Date Description 5.1 AREAWAY TRANS. VAULT STORAGE ROOM CORRIDOR SOILED LINEN GENERATOR ROOM STAIRS EQUIPMENT ROOM CORR. EL. 217.9 SOILED LINEN LOUNGE T.CORRIDORRAD STOR CORRIDORELEV. LOBBY SERVICE ELEV. COMMUNICATIONS ENVIRO SERV STORAGE PASS. FD FD DS VFC VFC M M M S1 S2 S3 FD FD NOTE: NEW FLOOR PENETRATION TO BE CONFIRMED WITH STRUCTURAL ENGINEER NOTE: NEW FLOOR PENETRATION TO BE CONFIRMED WITH STRUCTURAL ENGINEER NOTE: NEW FLOOR PENETRATION TO BE CONFIRMED WITH STRUCTURAL ENGINEER FD OLD HEAT LOOP PIPE LOW PRESSURE CONDENSATE UNKNOWN PIPE P-1P-2HEAT EXCHANGER S4 FD 2 H-100 1 2 3 4 5 6 8 9 10 11 12 CU-S2 CU-S1 DX-S1 DX-S2 REF REFREF REFREFINSTALL NEW DX COOLING COILS IN EXISTING AHU-S1 AND IN AHU-S2 IN SPACE WHERE OLD COILS WERE INSTALLED. RUN PIPING THROUGH ACCESSIBLE CEILING AREAS, RUN PIPING UP TO ROOF, CONNECT TO NEW CONDENSING UNITS. NEW CONDENSING UNITS MOUNTED ON ROOF REFRIGERANT PIPING UP TO LOW ROOFTOP REMOVE EXISTING HOT WATER PUMPS P-1 AND P-2 AND INSTALL NEW PUMPS, P-1 & P-2, ON EXISTING PAD. REPLACE ANY EXISTING VALVES AND TRIM PER DETAIL P-2P-1 REFREF7 7 2" HWR 2" HWS NEW 2" HOT WATER SUPPLY AND RETURN TO SERVE NEW VAV REHEAT COILS IN SCOPE OF WORK CONTRACTOR TO VERIFY EXACT SIZE OF NEW DX COOLING COILS NEEDED IN EXISTING AHU-S1 AND AHU-S2 IN THE SECTION WHERE THE OLD COILS WERE INSTALLED, IN THE FIELD. 26 EXISTING SUPPLY DUCT AND RISER NEW SUPPLY DUCT AND RISER STEAM COIL 12x18 FD Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:25:49 AMH-100 185-01-00 8/15/16 BASEMENT HVAC PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER DRAWING NOTES REMOVE EXISTING SUPPLY DUCT SECTION INSIDE ROOM INCLUDING, STEAM COIL AND ASSOCIATED PIPING WHICH NEEDS TO BE CAPPED. DISCONNECT EXISTING SUPPLY RISER FROM ELBOW IN GROUND FLOOR LEVEL CEILING SPACE ABOVE AND REMOVE. REMOVE EXISTING FIRE DAMPER AND SAVE FOR RE-USE. PATCH HOLE IN CEILING / FLOOR TO MATCH EXISTING. RUN NEW SUPPLY DUCT SECTION FROM INSIDE ROOM, MATCH EXISTING SIZE, (V.I.F.). OFFSET UP AFTER SPRINKLER MAIN AND ELBOW OVER EXISTING RELIEF AIR DUCT, ELBOW UP, ADD FIRE DAMPER, TRANSITION TO 20x20 AND RISE UP THROUGH NEW CHASE IN NEW OFFICE TO CEILING SPACE. OFFSET EXISTING PIPES RUNNING UP HIGH AROUND NEW RETURN DUCT PENETRATION. VERIFY SERVICE, SIZE AND MATERIALS IN FIELD. VERIFY SHUT-DOWN WITH HOSPITAL. NEW 26x14 RETURN DUCT UP TO GROUND FLOOR, OFFSET OVER O.A. PLENUM AND 90 ELBOW DOWN TO EXISTING BLANKED OFF MIXING AIR SECTION ON EXISTING AHU-S2. CUT EXISTING LOW PRESSURE STEAM CONDENSATE PAST CLOSEST DROP AND RUN OFFSET PIPE AROUND NEW RETURN DUCT DROP AND RECONNECT TO LPC ON OTHER SIDE OF NEW DUCT UP. CUT AND OFFSET OLD HEAT LOOP PIPE AROUND NEW RETURN DUCT DROP AND RECONNECT. REMOVE EXISTING OUTSIDE AIR DAMPER, PNEUMATIC ACTUATOR, AND ALL ASSOCIATED PIPING AND DEVICES BACK TO SOURCE. PROVIDE NEW RETURN AIR DAMPER AND MIN/MAX OUTSIDE AIR DAMPERS WITH ELECTRONIC ACTUATORS. LOCATE ACTUATORS ON THIS SIDE OF UNIT FOR ACCESS. REMOVE EXISTING PNEUMATIC STEAM CONTROL VALVES AND ALL ASSOCIATED CONTROL PIPING AND DEVICES. PROVIDE NEW STEAM CONTROL VALVES WITH ELECTRONIC ACTUATORS. CONFIRM EXISTING SIZING AND OPERATION. (E.G. 50/50, 1/3 - 2/3). REMOVE EXISTING SUPPLY DUCT ELBOW AND FIRE DAMPER SECTION FROM UP NEAR CEILING AND EXISTING SUPPLY DUCT BACK TO TRANSITION BEFORE STEAM COIL. REMOVE DUCT RISER GOING UP. PATCH HOLE IN CEILING TO MATCH EXISTING. STEAM COIL AND ASSOCIATED PIPING TO REMAIN IN PLACE. ATTACH NEW DUCT TO EXISTING TRANSITION AND RUN STRAIGHT ACROSS TOP OF EXISTING DUCT AND 90 ELBOW DOWN BETWEEN EXISTING DUCTS AS SHOWN IN DETAIL ON THIS SHEET. RUN NEW SUPPLY DUCT UNDER EXISTING DUCTWORK AND ELBOW UP TO RELOCATED RISER IN NEW CHASE UPSTAIRS. ADD FIRE DAMPER SAVED FROM DEMOLITION. REMOVE SECTION OF EXISTING STEAM CONDENSATE PIPE AND OFFSET AROUND NEW DUCT ROUTE AND RECONNECT TO CONDENSATE MAIN. 1 2 DRAWING NOTES SCALE: 1/4" = 1'-0"1 BASEMENT HVAC PLAN SCALE: 1/4" = 1'-0"2 NEW RISER SECTION DETAIL 3 4 5 6 7 8 9 10 11 12 Issuance Schedule Number Date Description FECT T T TT T T T T T T T T SD DS M T SCOPE OF WORK RADIOLOGIST WORKROOM G-124 ULTRASOUND EQUIPMENT TASK CHAIR (EXISTING) STRETCHER STRETCHER BIOPSY TABLE SUCTION DEVICE STERILE SUPPLY CART RED BOX BLACK BOX GUEST CHAIR STEREO MONITOR STAND SOILED LINEN HAMPER SOILED LINEN HAMPER GUEST CHAIR SHARPS EXAM TABLE SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR REFRIDGERATOR SHARPS SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR SHARPS GLOVES AQUISITION WORKSTATION WHEELCHAIR RED BOX WALL MOUNTED PADDLES SET UP TRAY SUCTION DEVICE C-ARMSOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR 5 MP MONITOR STAND FROM STEREOTATIC LARGE MAMMOGRAPHY G-120 AQUISITION WORKSTATION WHEELCHAIR SET UP TRAY SUCTION DEVICE C-ARM CLEAN WORK AREA G-126A INTERVIEW 2 G-117 PATIENT CHANGING ROOM 3 G-111C TASK CHAIR TASK CHAIRWALL MOUNTED PADDLES LARGE BIOPSY CHAIR PATIENT CHANGING ROOM 1 G-111D PATIENT CHANGING ROOM 2 G-111B STAFF TOILET G-130A TASK CHAIR EXAM 2 G-107 EXAM TABLE SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A TASK CHAIR BONE DENSITY G-113 GOWNED SUB-WAITING G-110 SOILED LINEN HAMPER TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR PRINTER FILM COPIER PRINTER TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR (EXISTING) BONE DENSITY TABLE BONE DENSITY WORKSTATION/CART WHEELCHAIR SCALE SOILED LINEN HAMPER GUEST CHAIR TASK CHAIR (EXISTING) STADIOMETER GLOVES PRINTER, SM SOAP PAPER TOILET PAPER SOAP PAPER TOILET PAPER PAPER SOAP SOILED LINEN BINTOILET PAPER TOILET PAPER COAT HOOKS CODE CART METRO RACK TRAY RACK 5 MP MONITOR STAND STEREO GENERATOR MIRCROWAVE KEURIG PURELL PURELL PURELL PURELL PURELL PURELL PURELLPURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL RED BOX SHARPS SHARPS TASK CHAIR (EXISTING) PURELL PURELL PURELLPURELL TASK CHAIR TASK CHAIR WITHOUT ARMS BACKERBOARD METRO RACK WOW TRASH STANDING WATER COOLER RECYCLE CONFIDENTIAL RECYCLE MOBILE PED MOBILE PED RADIOLOGIST WORKSTATION (EXISTING) RADIOLOGIST WORKSTATION (EXISTING) PHONE PHONE SIDE TABLE - SMALL TASK CHAIR WITHOUT ARMS STRETCHER ROUND TABLE WITH 4 CHAIRS LOUNGE CHAIR SCANNER SCANNER DESK DESK LOUNGE CHAIR PURELL INTERVIEW 1 G-118 ICE PAPER SOAP TRASH DEFIBRILLATOR SOAP PAPER PRINTER, SM TASK CHAIR STAFF BREAK ROOM G-123 CORRIDOR G-128 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B STRETCHER WAITING G-127 NURSE STATION G-126 ELECTRICAL CLOSET G-125 WAITING ROOM G-119 RECEPTION G-114C CORRIDOR G-119B WAITING ROOM PATIENT TOILET G-119A MEN'S CHANGING & WAITING G-114 PATIENT TOILET G-109 CORRIDOR G-115D CORRIDOR G-115C STEREOTACTIC G-105 NAVIGATOR'S OFFICE G-116 ULTRASOUND G-121MAMMOGRAPHY G-122 EXAM 1 G-106 COPIER RECYCLE WASTEBASKET PURELL SIDE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR WHEELCHAIR TRASH SOAP LOUNGE CHAIR LOUNGE CHAIR WATER LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE SETTEE COFFEE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE MOBILE PED BLACK BOX MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED TASK CHAIR WASTEBASKET RECYCLE TRASH RECYCLE WASTEBASKET SOILED LINEN HAMPER TRASH PAPER SOAP PAPER TRASH SOAP TRASH PHONE PAPER SOAP COAT HOOKS VIEW BOX TRASH PAPER SOAP PHONE PURELL PAPER SOAP PHONE PHONE WASTEBASKET RECYCLE SHARPS SHARPS SHARPS PHONE PHONE GLOVES GLOVESGLOVES PHONE PURELL SOAPPAPER TRASH WASTEBASKET RECYCLE SOAP PAPER PAPER SOAP PAPERSOAP TRASH GLOVESGLOVES SOAP PAPER PAPER PAPER SOAP PHONE TRASH TRASH PHONE COMPUTER COMPUTER PHONE PHONESHARPS SHARPS PHONE COMPUTER COMPUTER SOAP MIRROR, TALL MIRROR, TALL MIRROR, TALL MIRROR, TALL PAPER WATER TRASH TRASH WASTEBASKET PHONE COMPUTER COMPUTER PHONE WASTEBASKET COMPUTER PHONE PHONE TRASH WASTEBASKET RECYCLE RECYCLE RECYCLE TRASH TRASH TRASH COAT HOOKS TRASH UC FRIDGE PHONE COMPUTER STABLERISE STABLERISE SCANNER SCANNER SCANNER CPU CPU CPU SCANNER SCANNER SCANNER CPU CPU CPU OFFICE G-108 CPU CPU 5 7 8 910 1112131415 18 19 20 21 22 16 17 25 26 27 28 A4-130 A3-300 A3-300 A3-225 A2-120 A2-110 A2-120 A3-260 A3-260 A3-220 A4-500 B-75 A3-125 A3-110 A3-110 A4-200 A4-125 A3-300 A3-300 B-75 A4-185 A4-185 A3-100 A3-200 B-125 B-125 B-95 B-50 B-50 A2-50 A2-145 A2-60 A2-50 A2-50 B-75 A4-230 A3-110 A3-110 A2-185 A2-90 A2-65 A2-75 SCOPE B 555 690 155 B A 400 500 100 105 130 30 B 560 700 140 B 740 740 740 B-130 A2-90 B 600 600 600 B 385 470 95 20x1018x818x8 18x8 18x8 10x86x8 14x108ø 14x88x810ø 8x8 6x6 A4-60 B 12x10 12x1012x108x6 8x68ø10x106ø10x8 16x88ø12x1020x810x1010x8 8x6 8x68x6 8x6A FD FD 16x8 10x88øB 600 600 600 6ø10x8A 195 225 195 10x8370 370 370 400 500 100 12x10 8x8 8ø 18x6 8x8 6x6 8x6 6x6 8ø 14x1014x88x6 8x6 8x6 6x66x6 B 8x6 8x88x68x614x108x8 8ø 8ø14x12 12x108x6 8x614x1010x810x8 10x8 8x88x6 350 440 90 A3-500 B-675 16x108x6B-65 B-5206x6 6x6B-100 B-145 8x814x10 14x106x6 10x810x6 10x6 B-20014x812x8 8x6 B-110 B-120B-120 8x6B-80 8x68x68x6B-600 B-225 10x10 10x10 B-100 B-600 14x12 14x108x6 6x6B-55 B-150 B-220 14x12 10x612x10 B-425 12x10 12x108 x 6 8x626x148x8 24x12 22x1222x12 14x12NEW 26x14 RETURN DUCT DROP TO S-2 AHU IN BASEMENT BELOW 24x14 B-400 12x12 12x12 14x14 12x12 B-125 12x12 12x12 12x12 12x12 12x12 10x8 12x12 12x12 12x12 12x12 12x12 12x12 14x14 12x1012x12 B-110B-110 12x12 12x12 12x12 12x12 12x1212x12 12x12 12x12 12x12 12x12 12x12 18x12 12x12 12x12 26x1424x14 2 12x1012x10 A 260 325 100 B-145 12x128x610x6 8x610x88x8 10x610x814x810x810x8 3 FD ALTERNATE #1 DX PIPING UP TO LOW ROOF FROM BASEMENT FD 10x68x610x814x810x10 6x6 6x610x10 A 100 125 25 FD 8x8 A2-60 B-60 6x612x12 6x6 Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:25:55 AMH-101 185-01-00 8/15/16 GROUND FLOOR HVAC DUCTWORK PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER SCALE: 1/4" = 1'-0"1 GROUND FLOOR HVAC DUCTWORK PLAN DRAWING NOTES NEW SUPPLY RISER CONNECTED TO EXISTING SUPPLY DUCT. NEW SUPPLY DUCT RISER IN NEW CHASE DROPPED DOWN TO BASEMENT LEVEL AND RE-CONNECT TO EXISTING SUPPLY FROM AHU-3. COORDINATE MOVE WITH OWNER. WORK TO BE PERFORMED ON PREMIUM TIME IN ORDER TO MINIMIZE DISRUPTION. INSTALL NEW RELIEF AIR DUCT AND CONNECT TO NEW RETURN DUCT TO S2. ADD MOTORIZED DAMPERS TO CONTROL RETURN AND RELIEF AIR. NEW 20x20 SUPPLY RISER TRANSITIONED TO 28x14 CONNECTED TO EXISTING SUPPLY DUCT. 1 2 DRAWING NOTES 3 Issuance Schedule Number Date Description FECT T T TT T T T T T T T T SD DS M T SCOPE OF WORK RADIOLOGIST WORKROOM G-124 ULTRASOUND EQUIPMENT TASK CHAIR (EXISTING) STRETCHER STRETCHER BIOPSY TABLE SUCTION DEVICE STERILE SUPPLY CART RED BOX BLACK BOX GUEST CHAIR STEREO MONITOR STAND SOILED LINEN HAMPER SOILED LINEN HAMPER GUEST CHAIR SHARPS EXAM TABLE SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR REFRIDGERATOR SHARPS SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR SHARPS GLOVES AQUISITION WORKSTATION WHEELCHAIR RED BOX WALL MOUNTED PADDLES SET UP TRAY SUCTION DEVICE C-ARMSOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR 5 MP MONITOR STAND FROM STEREOTATIC LARGE MAMMOGRAPHY G-120 AQUISITION WORKSTATION WHEELCHAIR SET UP TRAY SUCTION DEVICE C-ARM CLEAN WORK AREA G-126A INTERVIEW 2 G-117 PATIENT CHANGING ROOM 3 G-111C TASK CHAIR TASK CHAIRWALL MOUNTED PADDLES LARGE BIOPSY CHAIR PATIENT CHANGING ROOM 1 G-111D PATIENT CHANGING ROOM 2 G-111B STAFF TOILET G-130A TASK CHAIR EXAM 2 G-107 EXAM TABLE SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A TASK CHAIR BONE DENSITY G-113 GOWNED SUB-WAITING G-110 SOILED LINEN HAMPER TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR PRINTER FILM COPIER PRINTER TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR (EXISTING) BONE DENSITY TABLE BONE DENSITY WORKSTATION/CART WHEELCHAIR SCALE SOILED LINEN HAMPER GUEST CHAIR TASK CHAIR (EXISTING) STADIOMETER GLOVES PRINTER, SM SOAP PAPER TOILET PAPER SOAP PAPER TOILET PAPER PAPER SOAP SOILED LINEN BINTOILET PAPER TOILET PAPER COAT HOOKS CODE CART METRO RACK TRAY RACK 5 MP MONITOR STAND STEREO GENERATOR MIRCROWAVE KEURIG PURELL PURELL PURELL PURELL PURELL PURELL PURELLPURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL RED BOX SHARPS SHARPS TASK CHAIR (EXISTING) PURELL PURELL PURELLPURELL TASK CHAIR TASK CHAIR WITHOUT ARMS BACKERBOARD METRO RACK WOW TRASH STANDING WATER COOLER RECYCLE CONFIDENTIAL RECYCLE MOBILE PED MOBILE PED RADIOLOGIST WORKSTATION (EXISTING) RADIOLOGIST WORKSTATION (EXISTING) PHONE PHONE SIDE TABLE - SMALL TASK CHAIR WITHOUT ARMS STRETCHER ROUND TABLE WITH 4 CHAIRS LOUNGE CHAIR SCANNER SCANNER DESK DESK LOUNGE CHAIR PURELL INTERVIEW 1 G-118 ICE PAPER SOAP TRASH DEFIBRILLATOR SOAP PAPER PRINTER, SM TASK CHAIR STAFF BREAK ROOM G-123 CORRIDOR G-128 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B STRETCHER WAITING G-127 NURSE STATION G-126 ELECTRICAL CLOSET G-125 WAITING ROOM G-119 RECEPTION G-114C CORRIDOR G-119B WAITING ROOM PATIENT TOILET G-119A MEN'S CHANGING & WAITING G-114 PATIENT TOILET G-109 CORRIDOR G-115D CORRIDOR G-115C STEREOTACTIC G-105 NAVIGATOR'S OFFICE G-116 ULTRASOUND G-121MAMMOGRAPHY G-122 EXAM 1 G-106 COPIER RECYCLE WASTEBASKET PURELL SIDE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR WHEELCHAIR TRASH SOAP LOUNGE CHAIR LOUNGE CHAIR WATER LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE SETTEE COFFEE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE MOBILE PED BLACK BOX MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED TASK CHAIR WASTEBASKET RECYCLE TRASH RECYCLE WASTEBASKET SOILED LINEN HAMPER TRASH PAPER SOAP PAPER TRASH SOAP TRASH PHONE PAPER SOAP COAT HOOKS VIEW BOX TRASH PAPER SOAP PHONE PURELL PAPER SOAP PHONE PHONE WASTEBASKET RECYCLE SHARPS SHARPS SHARPS PHONE PHONE GLOVES GLOVESGLOVES PHONE PURELL SOAPPAPER TRASH WASTEBASKET RECYCLE SOAP PAPER PAPER SOAP PAPERSOAP TRASH GLOVESGLOVES SOAP PAPER PAPER PAPER SOAP PHONE TRASH TRASH PHONE COMPUTER COMPUTER PHONE PHONESHARPS SHARPS PHONE COMPUTER COMPUTER SOAP MIRROR, TALL MIRROR, TALL MIRROR, TALL MIRROR, TALL PAPER WATER TRASH TRASH WASTEBASKET PHONE COMPUTER COMPUTER PHONE WASTEBASKET COMPUTER PHONE PHONE TRASH WASTEBASKET RECYCLE RECYCLE RECYCLE TRASH TRASH TRASH COAT HOOKS TRASH UC FRIDGE PHONE COMPUTER STABLERISE STABLERISE SCANNER SCANNER SCANNER CPU CPU CPU SCANNER SCANNER SCANNER CPU CPU CPU OFFICE G-108 CPU CPU 5 7 8 910 1112131415 18 19 20 21 22 16 17 25 26 27 28 EXISTING PIPE DROPS IN CHASE TO REMAIN B B A B B B B B A B A B NEW 2" HWS&R PIPE DROPS IN NEW CHASE 3/4" HWS3/4" HWR1" HWR 1" HWS 1" HWR 1" HWS 3/4" HWR 3/4" HWS 3/4" HWR 3/4" HWS 3/4" HWR 3/4" HWS 3/4" HWS 3/4" HWS 3/4" HWS 3/4" HWR 3/4" HWS 1" HWR 1" HWS 1" HWR 1" HWS 3/4" HWR 3/4" HWS 1 1/4" HWS1 1/4" HWR1 1/4" HWS1" HWS3/4" HWR1" HWR3/4" HWR 3/4" HWR A A Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:26:03 AMHP-101 185-01-00 8/15/16 GROUND FLOOR HVAC PIPING PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER SCALE: 1/4" = 1'-0"1 GROUND FLOOR HVAC PIPING PLAN Issuance Schedule Number Date Description BAL DAMPER MIN. R = W OTHERWISE USE VANED ELL W R 5 1 3 1 FLOWMAX SLOPE OF TRANSITIONS MIN RADIUS OF CURVED ELBOW DOUBLE VANE 5xW MIN .5WMINW/5W BRANCH TAKE-OFF VANED SQUARE ELBOWFLOWFLOW0 00 00 NOT TO SCALE DUCT CONSTRUCTIONDUCT CONSTRUCTION - 1:7 SLOPE FOR HIGH VELOCITY - 1:4 SLOPE FOR LOW VELOCITY NOTES: REDUCTION OF DUCT AREA NOT TO EXCEED 20% PLAN SEE NOTE ELEVATION ROUND DUCT TRANSFORMATION TO AVOID OBSTRUCTION CEILING PLAN ELEVATION AIR FLOW AIR FLOW RECTANGULAR DUCT TRANSFORMATION TO AVOID OBSTRUCTION AIR FLOW AIR FLOW OBSTRUCTION NOT TO SCALE DUCT OBSTRUCTION TRANSFORMATION DETAILS CEILING REDUCTION OF DUCT AREA NOT TO EXCEED 20% SEE NOTE OBSTRUCTION DUCT OBSTRUCTION TRANSFORMATION DETAILS 45° SIDE TAKE-OFF RECTANGULAR TO ROUND OR FLAT OVAL RECTANGULAR DUCT AIR FLOW VOLUME DAMPER (DO NOT INSTALL IN SUPPLY TO AIR TERMINAL UNITS) SUPPLY DUCT TO AIR TERMINAL UNIT OR SUPPLY DIFFUSER VD NOT TO SCALE 45° SUPPLY AIR TAKEOFF DETAIL45° SUPPLY AIR TAKEOFF DETAIL ROUND OR FLAT OVAL DUCT SUPPLY DUCT TO AIR TERMINAL UNIT CONICAL TEE BELLMOUTH TAKE-OFF SUPPLY DUCT TO AIR TERMINAL UNIT RECTANGULAR DUCT NOT TO SCALE VAV LOOP PRIMARY SUPPLY AIR TAKEOFF DETAILVAV LOOP PRIMARY SUPPLY AIR TAKEOFF DETAIL RECTANGULAR BRANCH DUCT RECTANGULAR MAIN DUCT 45° TAKE-OFF VD PROVIDE VOLUME DAMPER UPSTREAM/ DOWNSTREAM OF ALL BRANCH MAIN TAKEOFFS AND AT LAST TERMINAL RUNOUT AND EXCEPT AT LOCATIONS EXCLUDED IN SPECIFICATIONS INSTALL VOLUME DAMPER MINIMUM TWO DUCT WIDTHS FROM TAKEOFF PROVIDE VOLUME DAMPER EXCEPT AT LOCATIONS EXCLUDED IN SPECIFICATIONS VD NOT TO SCALE RECTANGULAR BRANCH DUCT TAKEOFF DETAIL0RECTANGULAR BRANCH DUCT TAKEOFF DETAIL PROVIDE 4' MINIMUM, 5' MAXIMUM STRAIGHT DUCT BETWEEN TRANSITION AND BOX SERVICE ACCESS PER MANUFACTURERS RECOMMENDATIONS, 18" MINIMUM PRIMARY AIR DUCT TRANSITION SHUTOFF VAV BOX NOT TO SCALE SUPPORT UNIT FROM STRUCTURE SHUTOFF VAV BOX UNION (TYP)MODULATING CONTROL VALVE MANUAL AIR VENT BALANCING VALVE HWR HWS SHUTOFF VALVE (TYP) STRAINER WITH BLOWDOWN VALVE HOSE BIBB, GASKETED CAP AND CHAIN HOT WATER REHEAT COIL HOSE END DRAIN VALVE WITH GASKETED CAP AND CHAIN TEST PLUG (TYP) NOTE: ALL RUNOUTS TO BE 3/4" UNLESS NOTED OTHERWISE. RUNOUTS LESS THAN 3/4" WILL NOT BE ACCEPTED. VAV HOT WATER REHEAT COIL PIPING DETAIL NOT TO SCALE VAV HOT WATER REHEAT COIL PIPING DETAIL YES NO ALLOWABLE FLOW CONFIGURATIONS IN PIPING TEES - HVAC SYSTEMS NOT TO SCALE YES NO ALLOWABLE FLOW CONFIGURATIONS IN PIPING TEES - HVAC SYSTEMS W 1-1/2W DOUBLE THICKNESS TURNING VANES AIRFLOW D1 D+D1 SLOPE 1" IN 7" 1"R 2"R 1" 1" 1" 1" AIRFLOW 45° SLOPE 1" IN 7" 1/4W, 4" MIN W AIRFLOW 45° 1/4W, 4" MIN W AIRFLOW D1 D+D1 D D 1-1/2W W AIRFLOW LONG RADIUS TEE SUPPLY DUCTS ONLY LONG RADIUS TEE RETURN DUCTS ONLY TAKE-OFFS SUPPLY DUCTS ONLY TAKE-OFFS RETURN DUCTS ONLY TAKE-OFF SUPPLY DUCTS ONLY TYPICAL TURNING VANE SUPPLY AND RETURN DUCTS FULL RADIUS ELBOW SUPPLY AND RETURN DUCTS SQUARE ELBOW SUPPLY AND RETURN DUCTS NOT TO SCALE DUCT DETAILS 0 0 0 0 0 0 0 00 D D0 000 0 DUCT DETAILS P SHUTOFF VALVE (TYP) FLEXIBLE CONNECTOR (TYP) COMMON PRESSURE GAUGE WITH SHUTOFF VALVES SUCTION DIFFUSER WITH SUPPORT FLOOR SUPPORT BASE 18" MIN CHECK VALVE REDUCER BASE MOUNTED PUMP DETAIL - VFC CONTROLLED NOT TO SCALE HOSE END DRAIN VALVE WITH GASKETED CAP AND CHAIN NOTE: APPLIES TO END SUCTION AND HORIZONTAL SPLIT CASE. - METERING ORIFICE VALVE Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. NOT TO SCALE 8/16/2016 11:25:56 AMH-400 185-01-00 8/15/16 HVAC DETAILS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER Issuance Schedule Number Date Description FECELEVATORELEVATORELEVATOR EXISTING EMERG MGMT STORAGE G03 EXISTING ED STORAGE G02 EXISTING OFFICE G01A EXISTING LOCKER ROOM G01 STAIR EXISTING ED LOCKER ROOM G20 EXISTING ED DR ON CALL SLEEP G19 EXISTING VEST. EXISTING EVS HSK G18 EXISTING OFFICE G17 SCOPE OF WORK EXISTING OFFICE G16 STORAGE OFFICE EXISTING ED CONF ROOM G05 EXISTING ED MEN'S LOCKER G15 EXISTING STORAGE G14 EXISTING ED ADMIN CLINICAL G13 EXTENT OF DEMO EXTENT OF DEMOEXTENT OF DEMO EXTENT OF FLOOR DEMO 5 7 8 910 1112131415 18 19 20 21 22 16 17 25 26 27 28 SL-2 2 1 EXISTING PANEL 3 3 3 REMOVE EXISTING ELECTRICAL PULLBOX Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:25:31 AMED-101 185-01-00 8/15/16 GROUND FLOOR ELECTRICAL DEMOLITION PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER DEMOLITION NOTES EXISTING PANEL SHALL BE DISCONNECTED AND REMOVED, INCLUDING FEEDERS BACK TO EXISTING SOURCE DISTRIBUTION PANEL IN BASEMENT. CONFIRM LOCATION OF SOURCE PANEL WITH HOSPITAL FACILITIES. EXISTING PANEL ‘SL-2’ SHALL BE DISCONNECTED AND REMOVED, INCLUDING FEEDERS BACK TO EXISTING SOURCE DISTRIBUTION PANEL ‘WWMP’ IN BASEMENT. ELECTRICAL CONTRACTOR SHALL ALLOCATE (6) BRANCH CIRCUITS TO BE UTILIZED TO RE-FEED EXISTING LOADS OUTSIDE OF THE PROPOSED SCOPE OR WORK TO THE PROPOSED NEW PANEL. THE PHASING AND CONSTRUCTION INTENT FOR THIS IS TO KEEP THE EXISTING PANELS ENERGIZED ON A TEMPORARY BASIS DURING THE PERIOD OF DEMOLITION AND CONSTRUCTION SUCH THAT THE AREAS OUTSIDE THE SCOPE OF WORK MAY REMAIN OPERATIONAL. ONCE THE NEW PANELS ARE INSTALLED AND ENERGIZED (SHOULD BE SCHEDULED TO BE CONSTRUCTED EARLY IN THE PROCESS), EXISTING BRANCH CIRCUITS SERVING AREAS OUTSIDE THE SCOPE OF WORK CAN BE EXTENDED OVER TO THE NEW PANELS. EXISTING PANEL ‘SL-1’ (LOCATED IN EXISTING CORRIDOR APPROXIMATELY 10’ PLAN NORTH OF NEW CORRIDOR DOORS) SHALL BE DISCONNECTED AND REMOVED, INCLUDING FEEDERS BACK TO EXISTING SOURCE DISTRIBUTION PANEL ‘WWMP’ IN BASEMENT. ELECTRICAL CONTRACTOR SHALL ALLOCATE (16) BRANCH CIRCUITS TO BE UTILIZED TO RE-FEED EXISTING LOADS OUTSIDE OF THE PROPOSED SCOPE OR WORK. THERE ARE APPROXIMATELY (6) ROOMS THAT REQUIRE EXISTING BRANCH CIRCUITS (LIGHTING AND POWER) TO BE EXTENDED AND FED FROM NEW PANEL ‘SL-1’ OR 'SL-2'. EXISTING CRITICAL BRANCH CIRCUITS SERVING SOME OF THE DEVICES IN THESE ROOMS SHALL REMAIN. THE PHASING AND CONSTRUCTION INTENT FOR THIS IS TO KEEP THE EXISTING PANELS ENERGIZED ON A TEMPORARY BASIS DURING THE PERIOD OF DEMOLITION AND CONSTRUCTION SUCH THAT THE AREAS OUTSIDE THE SCOPE OF WORK MAY REMAIN OPERATIONAL. ONCE THE NEW PANELS ARE INSTALLED AND ENERGIZED (SHOULD BE SCHEDULED TO BE CONSTRUCTED EARLY IN THE PROCESS), EXISTING BRANCH CIRCUITS SERVING AREAS OUTSIDE THE SCOPE OF WORK CAN BE EXTENDED OVER TO THE NEW PANELS. 1 2 SCALE: 1/4" = 1'-0"1 GROUND FLOOR ELECTRICAL DEMOLITION PLAN DEMOLITION NOTESGENERAL DEMOLITION NOTES DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL EQUIPMENT WITHIN DESIGNATED AREA FOR SCOPE OF WORK AND ON WALLS BEING REMOVED, EXCEPT WHERE MARKED OTHERWISE. THIS WORK INCLUDES COMPLETE DEMO AND IS NOT LIMITED TO THE EQUIPMENT SHOWN ON DEMO PLANS. EXISTING PANELS ON WALLS TO REMAIN SHALL BE LEFT OUT. DISCONNECT AND REMOVE EXISTING FIRE ALARM SYSTEM IN AREA DESIGNATED INCLUDING BUT NOT LIMITED TO F.A. DEVICES, WIRING, CONDUIT, BOXES, PANELS, ETC. COORDINATE REMOVAL WORK WITH INSTALLATION OF NEW FIRE ALARM SYSTEM DEVICES SUCH THAT AN OPERATIONAL FIRE ALARM SYSTEM IS MAINTAINED THROUGHOUT PERIODS OF BUILDING OCCUPATION. COORDINATE ANY SERVICE SHUT-DOWN WITH LOCAL FIRE OFFICIAL AND OWNER. PROVIDE FIRE WATCH AS REQUIRED. PROVIDE TEMPORARY SMOKE DETECTORS IN AREAS WHERE SPRINKLER SYSTEM WORK IS CONDUCTED TO MAINTAIN FIRE PROTECTION DURING CONSTRUCTION PERIOD. DISCONNECT AND REMOVE EXISTING WIRING, CONDUIT, BOXES, ETC. SERVING ALL EQUIPMENT BEING REMOVED BY MECHANICAL AND OTHER TRADES. REFER TO PLUMBING, MECHANICAL AND ARCHITECTURAL DRAWINGS FOR COORDINATION OF REQUIRED WORK. REMOVALS SHALL BE COMPLETE BACK TO SOURCE PANEL. EXISTING ELECTRICAL ITEMS THAT ARE BEING DISCONNECTED AND REMOVED AND NOT BEING REUSED SHALL BE DISPOSED OF PROPERLY. ALL ABANDONED ELECTRICAL WIRING AND DEVICES SHALL BE REMOVED. IF CONTINUITY OF WIRING TO EXISTING ELECTRICAL ITEMS IS INTERRUPTED BY REMOVAL OF DEVICES, CONTRACTOR SHALL INSTALL ALL NECESSARY WIRING AND RACEWAY TO ENSURE THE CONTINUITY OF CIRCUITRY IN OTHER AREAS. CONTRACTOR SHALL TRACE APPLICABLE BRANCH CIRCUITS AND MAINTAIN POWER TO AREAS OUTSIDE OF DEMOLITION SCOPE OF WORK. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL RELATED WORK. ALL EXISTING LIGHT FIXTURES BEING REMOVED BUT NOT BEING REUSED SHALL BE TURNED OVER TO THE OWNER. 1 2 3 4 5 6 7 8 3 Issuance Schedule Number Date Description 1 2016.07.08 ADDENDUM #1 A B C D E.1C.9 TRANS. VAULT STORAGE ROOM CORRIDOR GENERATOR ROOM EQUIPMENT ROOM EL. 217.9 SOILED LINENCORRIDOR T PUB ENVIRO SERV STORAGE FD FD VFC VFC B A DD A B C D E F G H J K L M 5.2 4.5 E.1 5.1 C.9 I AREAWAY GENERAL STORAGE RAMP UP STOREROOM GENERAL STORAGE EL. 217.9 LINEN STORAGE MEDICAL RECORDS RADIATION PROTECTION ROOM TRANS. VAULT STORAGE ROOM CORRIDOR SOILED LINEN GENERATOR ROOM CORR. ELEV. STAIRS EQUIPMENT ROOM CORR. EL. 217.9 SOILED LINEN X-RAY ROOM RAD STOR CORRIDORELECTRICAL ROOM MECHANICAL ROOM DECONTAMINATION EQUIP. WASH LOUNGE HSKP. OFFICE PROCESSED STORES SORTING & PACKING STERILIZERS STEAM LKRS FEMALE LKRSMALE TOIL FEMALE TOIL MALE SHWR AREAWAY AREAWAY ACCESS AREAWAY CENTRAL STERILE PROCESSING & STERILE STORES SOILED WORKROOM DISPATCH CORRIDOR ELEV. LOBBY SERVICE ELEV. LOBBY CORRIDOR CORR. SOILED CART STAGING AREA STAIR CONFERENCE ROOM B LINEN EQUIP. STORAGE HSKP. SOILED STAIR CORRIDOR STOR COMMUNICATIONS EMERGENCY ELECTRIC ROOM PBDS STORAGE BREAKOUT TEL/COM. RM. ELEV.ELEV. LINEN CONTROL CATH LAB T PATCLN SPLY SCRUB T PUBT PUB ENVIRO SERV STORAGE VIEWING/ FILM EQUIP PASS.PASS. PASS. T. STAFF PREP/RECOV PREP/RECOVPREP/RECOV WK AREA HSKPGSOIL UTL PASS. VEST. LKR RM LKR RM OFF NOUR MEDS MAYO XFCSUPPLY CART 3STERI25 STERI25 STERP01 PASST01 WASHD08 STILL03 STILL03A/C SHELM36 WASHD20 GUNST01COFFE15TUNNEL WASHER STERP01 REF.FD FD FD FD FD FD FD FD XFCXFCXFCFD XFC MGCVFDVCFDVCFDVCFD FD FD MIN. DOOR SIZECU-S2 CU-S1 P-2P-1 REMOVE EXISTING HOT WATER PUMPS P-1 AND P-2 AND INSTALL NEW PUMPS, P-1 & P-2, ON EXISTING PAD 2 NEW CONDENSING UNITS MOUNTED ON ROOF NEW PANEL 'PNL' 1 EXISTING DISTRIBUTION PANEL 'WWMP' TO REMAIN APPROXIMATE LOCATION OF PUMPS P2000 MAIN ELECTRIC ROOM (LOCATION OF PANEL 'EE-L5') Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. As indicated 8/16/2016 11:25:28 AME-100 185-01-00 8/15/16 BASEMENT ELECTRICAL PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER SCALE: 1/4" = 1'-0"1 BASEMENT ELECTRICAL PLAN DRAWING NOTES FURNISH AND INSTALL A NEW 480/277V PANEL RATED FOR 100A WITH A 90A MAIN CIRCUIT BREAKER. COORDINATE EXACT LOCATION FOR PANEL WITH HOSPITAL FACILITIES PRIOR TO MOUNTING. PANEL SHALL BE A 30 POLE UNIT WITH (1) 25A-3P BRANCH CIRCUIT BREAKER TO SERVE ‘CU- S1’ AND (1) 20A-3P BRANCH CIRCUIT BREAKER TO SERVE ‘CU-S2’. THE NEW PANEL SHALL BE FED FROM AN EXISTING 480V, 90A RATED FEEDER THAT IS FED FROM EXISTING DISTRIBUTION PANEL ‘N’. THE FEEDER IS CURRENTLY TERMINATED IN A BOX NEAR THE EXISTING AREAWAY AND SHALL BE CUT BACK AND UTILIZED TO SERVE THE NEW PANEL. COORDINATE THE EXACT LOCATION OF FEEDER WITH HOSPITAL FACILITIES. DISCONNECT AND REMOVE EXISTING BRANCH CIRCUITS SERVING EXISTING HOT WATER PUMPS ‘P-1’ AND ‘P-2’. UNITS ARE SERVED FROM AN EXISTING 208V PANEL WITHIN THE MECHANICAL ROOM. PROVIDE A NEW BRANCH CIRCUIT FOR EACH NEW PROPOSED PUMP ‘P-1’ AND ‘P-2’ (TO BE LOCATED IN SAME LOCATION). BRANCH CIRCUITS SHALL BE 480V; 3#10, 1#10G., IN 3/4” CONDUIT FROM A NEW 25A-3P CIRCUIT BREAKER IN EXISTING PANEL ‘EE-L5’. THIS PANEL IS LOCATED IN THE ESSENTIAL EMERGENCY SIDE OF THE P2000 MAIN ELECTRIC ROOM. 1 2 GENERAL NOTES COORDINATE EXACT LOCATION OF ELECTRICAL DEVICES SUCH AS LIGHTING, EXIT SIGNS, SWITCHES, RECEPTACLES, DATA/TEL., FIRE ALARM DEVICES, ETC., WITH ALL DEVICES WITHIN MECHANICAL AND ELECTRICAL ROOMS SHALL BE COORDINATED WITH PANELS, DUCTWORK, PIPING, CONDUIT, ETC. FOR FINAL LOCATIONS. TYPICAL HOMERUN FOR EACH BRANCH CIRCUIT SHALL BE FED BY 2#12,1#12G.,3/4" CONDUIT TO A 20A-1P CIRCUIT BREAKER IN PANELBOARD AS DESIGNATED, UNLESS SHOWN OTHERWISE. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION SYSTEMS IN ABOVE CEILING SPACE TO PERMIT THE PLACEMENT OF LIGHTS, DEVICES, AND SPRINKLER HEADS IN THE EXACT LOCATION SHOWN ON THE ARCHITECTURAL DRAWINGS. TYPICAL WIRING AND INTENT FOR OPERATION OF ROOMS AND CORRIDORS WITH EMERGENCY AND NORMAL LIGHTING POWER INCLUDES: OCCUPANCY SENSOR AND EMERGENCY RELAY FOR CONTROL OF BOTH NORMAL AND EMERGENCY LIGHTING FIXTURES, PROVIDE BYPASS RELAY FOR ENERGIZING EMERGENCY LIGHTING UPON LOSS OF NORMAL POWER WHEN THE EMERGENCY FIXTURE(S) ARE OFF. FLOOR PLANS SHOW NORMAL BRANCH CIRCUIT GRAPHICAL CLARIFICATION. REFER TO SPECIFIC LIGHTING WIRING DIAGRAMS ON DETAIL DRAWINGS FOR SCHEMATIC WIRING INTENT OF OPERATION. ROOMS THAT ARE FED VIA MANUAL SWITCHES (IE:ELECTRIC & TELCOM): PROVIDE EMERGENCY RELAY MODUAL FOR ROOM PER DETAIL ON DRAWING #E200 TO PROVIDE CONTROL AND ENSURE ACTIVATION OF EMERGENCY LIGHTING IN THE EVENT OF LOSS OF NORMAL POWER. 1. 2. 3. 4. DRAWING NOTES GENERAL NOTES 5. SCALE: 3/32" = 1'-0"2 BASEMENT ELECTRICAL PLAN Issuance Schedule Number Date Description 1 2016.07.12 ADDENDUM #2 FECDOC OC D DDD DD D OCDOCDD DVS VS DDDD OC 3 3D OC OC DDD D DDDD D DD VSVS VS OC D D OC OC J D3 D3 SD DS MDDSCOPE OF WORK RADIOLOGIST WORKROOM G-124 ULTRASOUND EQUIPMENT TASK CHAIR (EXISTING) STRETCHER STRETCHER BIOPSY TABLE SUCTION DEVICE STERILE SUPPLY CART RED BOX BLACK BOX GUEST CHAIR STEREO MONITOR STAND SOILED LINEN HAMPER SOILED LINEN HAMPER GUEST CHAIR SHARPS EXAM TABLE SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR REFRIDGERATOR SHARPS SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR SHARPS GLOVES AQUISITION WORKSTATION WHEELCHAIR RED BOX WALL MOUNTED PADDLES SET UP TRAY SUCTION DEVICE C-ARMSOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR 5 MP MONITOR STAND FROM STEREOTATIC LARGE MAMMOGRAPHY G-120 AQUISITION WORKSTATION WHEELCHAIR SET UP TRAY SUCTION DEVICE C-ARM CLEAN WORK AREA G-126A INTERVIEW 2 G-117 PATIENT CHANGING ROOM 3 G-111C TASK CHAIR TASK CHAIRWALL MOUNTED PADDLES LARGE BIOPSY CHAIR PATIENT CHANGING ROOM 1 G-111D PATIENT CHANGING ROOM 2 G-111B STAFF TOILET G-130A TASK CHAIR EXAM 2 G-107 EXAM TABLE SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A TASK CHAIR BONE DENSITY G-113 GOWNED SUB-WAITING G-110 SOILED LINEN HAMPER TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR PRINTER FILM COPIER PRINTER TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR (EXISTING) BONE DENSITY TABLE BONE DENSITY WORKSTATION/CART WHEELCHAIR SCALE SOILED LINEN HAMPER GUEST CHAIR TASK CHAIR (EXISTING) STADIOMETER GLOVES PRINTER, SM SOAP PAPER TOILET PAPER SOAP PAPER TOILET PAPER PAPER SOAP SOILED LINEN BINTOILET PAPER TOILET PAPER COAT HOOKS CODE CART METRO RACK TRAY RACK 5 MP MONITOR STAND STEREO GENERATOR MIRCROWAVE KEURIG PURELL PURELL PURELL PURELL PURELL PURELL PURELLPURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL RED BOX SHARPS SHARPS TASK CHAIR (EXISTING) PURELL PURELL PURELLPURELL TASK CHAIR TASK CHAIR WITHOUT ARMS BACKERBOARD METRO RACK WOW TRASH STANDING WATER COOLER RECYCLE CONFIDENTIAL RECYCLE MOBILE PED MOBILE PED RADIOLOGIST WORKSTATION (EXISTING) RADIOLOGIST WORKSTATION (EXISTING) PHONE PHONE SIDE TABLE - SMALL TASK CHAIR WITHOUT ARMS STRETCHER ROUND TABLE WITH 4 CHAIRS LOUNGE CHAIR SCANNER SCANNER DESK DESK LOUNGE CHAIR PURELL INTERVIEW 1 G-118 ICE PAPER SOAP TRASH DEFIBRILLATOR SOAP PAPER PRINTER, SM TASK CHAIR STAFF BREAK ROOM G-123 CORRIDOR G-128 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B STRETCHER WAITING G-127 NURSE STATION G-126 ELECTRICAL CLOSET G-125 WAITING ROOM G-119 RECEPTION G-114C CORRIDOR G-119B WAITING ROOM PATIENT TOILET G-119A MEN'S CHANGING & WAITING G-114 PATIENT TOILET G-109 CORRIDOR G-115D CORRIDOR G-115C STEREOTACTIC G-105 NAVIGATOR'S OFFICE G-116 ULTRASOUND G-121MAMMOGRAPHY G-122 EXAM 1 G-106 COPIER RECYCLE WASTEBASKET PURELL SIDE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR WHEELCHAIR TRASH SOAP LOUNGE CHAIR LOUNGE CHAIR WATER LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE SETTEE COFFEE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE MOBILE PED BLACK BOX MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED TASK CHAIR WASTEBASKET RECYCLE TRASH RECYCLE WASTEBASKET SOILED LINEN HAMPER TRASH PAPER SOAP PAPER TRASH SOAP TRASH PHONE PAPER SOAP COAT HOOKS VIEW BOX TRASH PAPER SOAP PHONE PURELL PAPER SOAP PHONE PHONE WASTEBASKET RECYCLE SHARPS SHARPS SHARPS PHONE PHONE GLOVES GLOVESGLOVES PHONE PURELL SOAPPAPER TRASH WASTEBASKET RECYCLE SOAP PAPER PAPER SOAP PAPERSOAP TRASH GLOVESGLOVES SOAP PAPER PAPER PAPER SOAP PHONE TRASH TRASH PHONE COMPUTER COMPUTER PHONE PHONESHARPS SHARPS PHONE COMPUTER COMPUTER SOAP MIRROR, TALL MIRROR, TALL MIRROR, TALL MIRROR, TALL PAPER WATER TRASH TRASH WASTEBASKET PHONE COMPUTER COMPUTER PHONE WASTEBASKET COMPUTER PHONE PHONE TRASH WASTEBASKET RECYCLE RECYCLE RECYCLE TRASH TRASH TRASH COAT HOOKS TRASH UC FRIDGE PHONE COMPUTER STABLERISE STABLERISE SCANNER SCANNER SCANNER CPU CPU CPU SCANNER SCANNER SCANNER CPU CPU CPU OFFICE G-108 CPU CPU A1 A1 B1B1 A1 B1 A3 A3 A3 A3 A2 A2 A2 A2 A2 A2 A2 A1A1 A1 A1 A1 A1 A1 A1 A1 B1 B1 A1 A1A4A2 A2 A4 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A1 A2 A2 A2 A2 A2 A3 A3 A3A3 A3 A3 A3 A3 A3A3 A3 A3 A2 A2 A2 A2 A2 A2 A2 A2A2 A2 A2 A2 W1 U1 U1 U1 W1 U1 U1 U1 U1 X2 U1 U1 X2X2 A1A1A1A1A1A1A1 A1 A1 A1 A1 A1 A1 A1 X1 X1 5 7 8 910 1112131415 18 19 20 21 22 16 17 25 26 27 28 A1 A1 D1 D1 D1 D1 D1 D1 A1 NL NL NL NL NL SL-1 SL-2 SL-1 SL-1 SL-1 SL-1 SL-1 SL-1 SL-1 A4 A4 U1 1 NL U1 U1 1 1 U11 U1U1 1U1 U1 U1 U1 1 W2 W2 U1 1 U1 1 U1 U1 U1 1 B1 B1 D1 D1W1 A1 A1 A1 A1 A1 1 A1 W1 C1 C1 U1 U1 1 C1 C1 C1 C1 C1 U1 U1 U1 2 A1 A1 A1 A1 EXISTING LIGHTING TO REMAIN (TYP.) 3 X1 U1 1 U1 Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:25:35 AMEL-101 185-01-00 8/15/16 GROUND FLOOR ELECTRICAL LIGHTING PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER DRAWING NOTES WIRED TO LOCAL 120V BRANCH CIRCUIT. COORDINATE SWITCH LOCATION WITH ARCHITECT. TIED INTO LOCAL EXISTING NIGHT LIGHT CIRCUIT SERVING CORRIDOR FROM EXISTING PANEL "LS3GA". PROVIDE POWER FOR EXAM LIGHT. (FIXTURE FURNISHED BY OWNER, INSTALLED BY CONTRACTOR). UNIT HAS INTEGRAL ON/OFF SWITCH. 1 2 SCALE: 1/4" = 1'-0"1 GROUND FLOOR ELECTRICAL LIGHTING PLAN GENERAL NOTES COORDINATE EXACT LOCATION OF ELECTRICAL DEVICES SUCH AS LIGHTING, EXIT SIGNS, SWITCHES, RECEPTACLES, DATA/TEL., FIRE ALARM DEVICES, ETC., WITH ALL DEVICES WITHIN MECHANICAL AND ELECTRICAL ROOMS SHALL BE COORDINATED WITH PANELS, DUCTWORK, PIPING, CONDUIT, ETC. FOR FINAL LOCATIONS. TYPICAL HOMERUN FOR EACH BRANCH CIRCUIT SHALL BE FED BY 2#12,1#12G.,3/4" CONDUIT TO A 20A-1P CIRCUIT BREAKER IN PANELBOARD AS DESIGNATED, UNLESS SHOWN OTHERWISE. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION SYSTEMS IN ABOVE CEILING SPACE TO PERMIT THE PLACEMENT OF LIGHTS, DEVICES, AND SPRINKLER HEADS IN THE EXACT LOCATION SHOWN ON THE ARCHITECTURAL DRAWINGS. TYPICAL WIRING AND INTENT FOR OPERATION OF ROOMS AND CORRIDORS WITH EMERGENCY AND NORMAL LIGHTING POWER INCLUDES: OCCUPANCY SENSOR AND EMERGENCY RELAY FOR CONTROL OF BOTH NORMAL AND EMERGENCY LIGHTING FIXTURES, PROVIDE BYPASS RELAY FOR ENERGIZING EMERGENCY LIGHTING UPON LOSS OF NORMAL POWER WHEN THE EMERGENCY FIXTURE(S) ARE OFF. FLOOR PLANS SHOW NORMAL BRANCH CIRCUIT GRAPHICAL CLARIFICATION. REFER TO SPECIFIC LIGHTING WIRING DIAGRAMS ON DETAIL DRAWINGS FOR SCHEMATIC WIRING INTENT OF OPERATION. ROOMS THAT ARE FED VIA MANUAL SWITCHES (IE:ELECTRIC & TELCOM): PROVIDE EMERGENCY RELAY MODUAL FOR ROOM PER DETAIL ON DRAWING #E200 TO PROVIDE CONTROL AND ENSURE ACTIVATION OF EMERGENCY LIGHTING IN THE EVENT OF LOSS OF NORMAL POWER. 1. 2. 3. 4. DRAWING NOTESGENERAL NOTES 3 5. Issuance Schedule Number Date Description FECa GF a GF a GF TPTP TP aGFa GF a GF a aGFaGFa GF a GF TP TPGFTPTPTPTP a GF aGFaGFGFa GF a GF GFa GF aGFaGFa GF a GFGFa GFGF aGFTP TPTP TPTPTP GF aGFa GF GF SD DS M aa GF TPTPa SCOPE OF WORK RADIOLOGIST WORKROOM G-124 ULTRASOUND EQUIPMENT TASK CHAIR (EXISTING) STRETCHER STRETCHER BIOPSY TABLE SUCTION DEVICE STERILE SUPPLY CART RED BOX BLACK BOX GUEST CHAIR STEREO MONITOR STAND SOILED LINEN HAMPER SOILED LINEN HAMPER GUEST CHAIR SHARPS EXAM TABLE SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR REFRIDGERATOR SHARPS SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR SHARPS GLOVES AQUISITION WORKSTATION WHEELCHAIR RED BOX WALL MOUNTED PADDLES SET UP TRAY SUCTION DEVICE C-ARMSOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR 5 MP MONITOR STAND FROM STEREOTATIC LARGE MAMMOGRAPHY G-120 AQUISITION WORKSTATION WHEELCHAIR SET UP TRAY SUCTION DEVICE C-ARM CLEAN WORK AREA G-126A INTERVIEW 2 G-117 PATIENT CHANGING ROOM 3 G-111C TASK CHAIR TASK CHAIRWALL MOUNTED PADDLES LARGE BIOPSY CHAIR PATIENT CHANGING ROOM 1 G-111D PATIENT CHANGING ROOM 2 G-111B STAFF TOILET G-130A TASK CHAIR EXAM 2 G-107 EXAM TABLE SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A TASK CHAIR BONE DENSITY G-113 GOWNED SUB-WAITING G-110 SOILED LINEN HAMPER TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR PRINTER FILM COPIER PRINTER TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR (EXISTING) BONE DENSITY TABLE BONE DENSITY WORKSTATION/CART WHEELCHAIR SCALE SOILED LINEN HAMPER GUEST CHAIR TASK CHAIR (EXISTING) STADIOMETER GLOVES PRINTER, SM SOAP PAPER TOILET PAPER SOAP PAPER TOILET PAPER PAPER SOAP SOILED LINEN BINTOILET PAPER TOILET PAPER COAT HOOKS CODE CART METRO RACK TRAY RACK 5 MP MONITOR STAND STEREO GENERATOR MIRCROWAVE KEURIG PURELL PURELL PURELL PURELL PURELL PURELL PURELLPURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL RED BOX SHARPS SHARPS TASK CHAIR (EXISTING) PURELL PURELL PURELLPURELL TASK CHAIR TASK CHAIR WITHOUT ARMS BACKERBOARD METRO RACK WOW TRASH STANDING WATER COOLER RECYCLE CONFIDENTIAL RECYCLE MOBILE PED MOBILE PED RADIOLOGIST WORKSTATION (EXISTING) RADIOLOGIST WORKSTATION (EXISTING) PHONE PHONE SIDE TABLE - SMALL TASK CHAIR WITHOUT ARMS STRETCHER ROUND TABLE WITH 4 CHAIRS LOUNGE CHAIR SCANNER SCANNER DESK DESK LOUNGE CHAIR PURELL INTERVIEW 1 G-118 ICE PAPER SOAP TRASH DEFIBRILLATOR SOAP PAPER PRINTER, SM TASK CHAIR STAFF BREAK ROOM G-123 CORRIDOR G-128 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B STRETCHER WAITING G-127 NURSE STATION G-126 ELECTRICAL CLOSET G-125 WAITING ROOM G-119 RECEPTION G-114C CORRIDOR G-119B WAITING ROOM PATIENT TOILET G-119A MEN'S CHANGING & WAITING G-114 PATIENT TOILET G-109 CORRIDOR G-115D CORRIDOR G-115C STEREOTACTIC G-105 NAVIGATOR'S OFFICE G-116 ULTRASOUND G-121MAMMOGRAPHY G-122 EXAM 1 G-106 COPIER RECYCLE WASTEBASKET PURELL SIDE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR WHEELCHAIR TRASH SOAP LOUNGE CHAIR LOUNGE CHAIR WATER LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE SETTEE COFFEE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE MOBILE PED BLACK BOX MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED TASK CHAIR WASTEBASKET RECYCLE TRASH RECYCLE WASTEBASKET SOILED LINEN HAMPER TRASH PAPER SOAP PAPER TRASH SOAP TRASH PHONE PAPER SOAP COAT HOOKS VIEW BOX TRASH PAPER SOAP PHONE PURELL PAPER SOAP PHONE PHONE WASTEBASKET RECYCLE SHARPS SHARPS SHARPS PHONE PHONE GLOVES GLOVESGLOVES PHONE PURELL SOAPPAPER TRASH WASTEBASKET RECYCLE SOAP PAPER PAPER SOAP PAPERSOAP TRASH GLOVESGLOVES SOAP PAPER PAPER PAPER SOAP PHONE TRASH TRASH PHONE COMPUTER COMPUTER PHONE PHONESHARPS SHARPS PHONE COMPUTER COMPUTER SOAP MIRROR, TALL MIRROR, TALL MIRROR, TALL MIRROR, TALL PAPER WATER TRASH TRASH WASTEBASKET PHONE COMPUTER COMPUTER PHONE WASTEBASKET COMPUTER PHONE PHONE TRASH WASTEBASKET RECYCLE RECYCLE RECYCLE TRASH TRASH TRASH COAT HOOKS TRASH UC FRIDGE PHONE COMPUTER STABLERISE STABLERISE SCANNER SCANNER SCANNER CPU CPU CPU SCANNER SCANNER SCANNER CPU CPU CPU OFFICE G-108 CPU CPU 5 7 8 910 1112131415 18 19 20 21 22 16 17 25 26 27 28 SL-1 SL-2 SL-1 SL-1 SL-1 SL-1 SL-1 SL-2 SL-1 SL-1 SL-2 SL-2 SL-1 SL-1 SL-1 SL-1 SL-1 SL-1 SL-1 SL-1 SL-1 SL-1 SL-2 SL-1 SL-1 SL-1 SL-1 5 5 X3 X3 SL-1 4 8 6 8 7 SL-2 X3 5 4 1 SL-2 SL-2 SL-2 7 8 SL-28 6 4 SL-2 SL-2 SL-2 3B 3A 3B 2 SL-1 TP SL-1 ICE SL-1 SL-1 Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:25:39 AMEP-101 185-01-00 8/15/16 GROUND FLOOR ELECTRICAL POWER PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER DRAWING NOTES PROVIDE A 250V, 40A-2P ENCLOSED CIRCUIT BREAKER WITH SHUNT TRIP ACCESSORY. UNIT SHALL BE WALL MOUNTED AS SHOWN. PROVIDE 3#8, 1#10G. IN 1” CONDUIT FROM A 40A-2P CIRCUIT BREAKER IN PANEL ‘SL-2’ TO SERVE THE WALL MOUNT CIRCUIT BREAKER. THEN PROVIDE SAME FEEDER/CONDUIT FROM WALL MOUNT CIRCUIT BREAKER TO THE WIREWAY AND RUN FEEDER IN POWER SECTION OF WIREWAY TO FEED THE STEREO GENERATOR. WIREWAY (10” WIDE X 3-1/2”D) WITH (2) SECTION BARRIER. VERTICAL RUN UNIT DROP FROM CEILING. TIES INTO HORIZONTAL SECTION ABOVE ACCESSIBLE CEILING AND TO HORIZONTAL SECTION RUN. WIREWAY (10” WIDE X 3-1/2”D) WITH (2) SECTION BARRIER. HORIZONTAL RUN UNIT ABOVE ACCESSIBLE CEILING. COORDINATE ROUTING WITH EXISTING EQUIPMENT. WIREWAY (10” WIDE X 3-1/2”D) WITH (2) SECTION BARRIER. HORIZONTAL RUN UNIT RUN ALONG WALL AT 12”AFF (TO BOTTOM OF UNIT) CONNECTING VERTICAL RUN UNIT TO AREA BEHIND STEREO GENERATOR AND CONNECTING INTO CONTROL ROOM BELOW COUNTER. PROVIDE GROMMETTED CUT-OUT IN WIREWAY AT THE STEREO GENERATOR, CONTROL ROOM COUNTER EQUIPMENT AND MONITOR STAND. REFER TO HOLOGIC PRE-INSTALLATION GUIDE AND SITE REPRESENTATIVE FOR LOCATIONS AND REQUIREMENTS. REMOTE MOUNTED EMERGENCY POWER-OFF SHUNT TRIP BUTTON (BY CONTRACTOR). PROVIDE COVER FOR BUTTON. XRAY WARNING LIGHT (BY CONTRACTOR). REFER TO HOLOGIC PRE- INSTALLATION GUIDE AND SITE REPRESENTATIVE FOR LOCATIONS AND REQUIREMENTS. LIGHT SPECIFIED IN THE LIGHTING FIXTURE SCHEDULE. PROVIDE A 250V, 40A-2P ENCLOSED CIRCUIT BREAKER WITH SHUNT TRIP ACCESSORY. UNIT SHALL BE WALL MOUNTED AS SHOWN. PROVIDE 3#8, 1#10G. IN 1” CONDUIT FROM A 40A-2P CIRCUIT BREAKER IN PANEL ‘SL-2’ TO SERVE THE WALL MOUNT CIRCUIT BREAKER. WIREMOLD TYPE 4000 SERIES HORIZONTAL RACEWAY WITH (2) SECTION BARRIER. MOUNT AT 12”AFF. REFER TO HOLOGIC PRE-INSTALLATION GUIDE AND SITE REPRESENTATIVE FOR LOCATIONS AND REQUIREMENTS. WIREMOLD TYPE 4000 SERIES VERTICAL RACEWAY WITH (2) SECTION BARRIER. REFER TO HOLOGIC PRE-INSTALLATION GUIDE AND SITE REPRESENTATIVE FOR LOCATIONS AND REQUIREMENTS. 1 2 SCALE: 1/4" = 1'-0"1 GROUND FLOOR ELECTRICAL POWER PLAN GENERAL NOTES COORDINATE EXACT LOCATION OF ELECTRICAL DEVICES SUCH AS LIGHTING, EXIT SIGNS, SWITCHES, RECEPTACLES, DATA/TEL., FIRE ALARM DEVICES, ETC., WITH ALL DEVICES WITHIN MECHANICAL AND ELECTRICAL ROOMS SHALL BE COORDINATED WITH PANELS, DUCTWORK, PIPING, CONDUIT, ETC. FOR FINAL LOCATIONS. TYPICAL HOMERUN FOR EACH BRANCH CIRCUIT SHALL BE FED BY 2#12,1#12G.,3/4" CONDUIT TO A 20A-1P CIRCUIT BREAKER IN PANELBOARD AS DESIGNATED, UNLESS SHOWN OTHERWISE. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION SYSTEMS IN ABOVE CEILING SPACE TO PERMIT THE PLACEMENT OF LIGHTS, DEVICES, AND SPRINKLER HEADS IN THE EXACT LOCATION SHOWN ON THE ARCHITECTURAL DRAWINGS. 1. 2. 3. 4. DRAWING NOTESGENERAL NOTES 3 4 5 6 7 8 PROVIDE A NEW PANEL ‘SL1’ AS SHOWN ON DRAWINGS. REFER TO PANEL SCHEDULE ON ‘MEP’ DRAWINGS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. PROVIDE 4#2, 1#8G. IN 1-1/2” CONDUIT FROM AN EXISTING 100A-3P CIRCUIT BREAKER (MADE SPARE BY DEMOLITION) IN EXISTING MAIN DISTRIBUTION PANEL ‘WWMP’ LOCATED IN THE BASEMENT ELECTRIC ROOM BELOW. REFER TO DEMOLITION/EXISTING DRAWING FOR LOCATION OF EXISTING BASEMENT ELECTRIC ROOM. PROVIDE A NEW PANEL ‘SL2’ AS SHOWN ON DRAWINGS. REFER TO PANEL SCHEDULE ON ‘MEP’ DRAWINGS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. PROVIDE 4#4/0, 1#4G. IN 2- 1/2” CONDUIT FROM A NEW 200A-3P CIRCUIT BREAKER IN EXISTING MAIN DISTRIBUTION PANEL ‘WWMP’ LOCATED IN THE BASEMENT ELECTRIC ROOM BELOW. (REMOVE EXISTING 100A-3P CIRCUIT BREAKER MADE SPARE BY DEMOLITION AND REPLACE WITH NEW CIRCUIT BREAKER AS REQUIRED). REFER TO DEMOLITION/EXISTING DRAWING FOR LOCATION OF EXISTING BASEMENT ELECTRIC ROOM. ELECTRICAL CONTRACTOR SHALL PROVIDE A PULLBOX ABOVE EXISTING PANEL ‘WWMP’ IN BASEMENT AND LEAVE FEEDERS FROM NEW PANELS ‘SL-1’ AND ‘SL-2’ WITH 12’ OF EXTRA CONDUCTOR LENGTH. THIS IS FOR HOSPITAL TO PERFORM ‘LIVE- WORK’ TIE-IN TO EXISTING PANEL. PROVIDE NEW CIRCUIT BREAKER, AS REQUIRED, AND LEAVE FOR FACILITIES WITHIN ROOM. COORDINATE WORK AND TIMING WITH HOSPITAL FACILITIES. 1. 2. POWER DISTRIBUTION NOTES 3A 3B 3. Issuance Schedule Number Date Description E E NNS F NDNDNN N NA NA NDNDND NNNN E E NA NSNSND MNS ND ES S S SSSS S S S S S S S CR CRPPPPPP CR PP J J S SD DS M NS NS NAE E N S SCOPE OF WORK RADIOLOGIST WORKROOM G-124 ULTRASOUND EQUIPMENT TASK CHAIR (EXISTING) STRETCHER STRETCHER BIOPSY TABLE SUCTION DEVICE STERILE SUPPLY CART RED BOX BLACK BOX GUEST CHAIR STEREO MONITOR STAND SOILED LINEN HAMPER SOILED LINEN HAMPER GUEST CHAIR SHARPS EXAM TABLE SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR REFRIDGERATOR SHARPS SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR SHARPS GLOVES AQUISITION WORKSTATION WHEELCHAIR RED BOX WALL MOUNTED PADDLES SET UP TRAY SUCTION DEVICE C-ARMSOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR 5 MP MONITOR STAND FROM STEREOTATIC LARGE MAMMOGRAPHY G-120 AQUISITION WORKSTATION WHEELCHAIR SET UP TRAY SUCTION DEVICE C-ARM CLEAN WORK AREA G-126A INTERVIEW 2 G-117 PATIENT CHANGING ROOM 3 G-111C TASK CHAIR TASK CHAIRWALL MOUNTED PADDLES LARGE BIOPSY CHAIR PATIENT CHANGING ROOM 1 G-111D PATIENT CHANGING ROOM 2 G-111B STAFF TOILET G-130A TASK CHAIR EXAM 2 G-107 EXAM TABLE SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A TASK CHAIR BONE DENSITY G-113 GOWNED SUB-WAITING G-110 SOILED LINEN HAMPER TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR PRINTER FILM COPIER PRINTER TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR (EXISTING) BONE DENSITY TABLE BONE DENSITY WORKSTATION/CART WHEELCHAIR SCALE SOILED LINEN HAMPER GUEST CHAIR TASK CHAIR (EXISTING) STADIOMETER GLOVES PRINTER, SM SOAP PAPER TOILET PAPER SOAP PAPER TOILET PAPER PAPER SOAP SOILED LINEN BINTOILET PAPER TOILET PAPER COAT HOOKS CODE CART METRO RACK TRAY RACK 5 MP MONITOR STAND STEREO GENERATOR MIRCROWAVE KEURIG PURELL PURELL PURELL PURELL PURELL PURELL PURELLPURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL RED BOX SHARPS SHARPS TASK CHAIR (EXISTING) PURELL PURELL PURELLPURELL TASK CHAIR TASK CHAIR WITHOUT ARMS BACKERBOARD METRO RACK WOW TRASH STANDING WATER COOLER RECYCLE CONFIDENTIAL RECYCLE MOBILE PED MOBILE PED RADIOLOGIST WORKSTATION (EXISTING) RADIOLOGIST WORKSTATION (EXISTING) PHONE PHONE SIDE TABLE - SMALL TASK CHAIR WITHOUT ARMS STRETCHER ROUND TABLE WITH 4 CHAIRS LOUNGE CHAIR SCANNER SCANNER DESK DESK LOUNGE CHAIR PURELL INTERVIEW 1 G-118 ICE PAPER SOAP TRASH DEFIBRILLATOR SOAP PAPER PRINTER, SM TASK CHAIR STAFF BREAK ROOM G-123 CORRIDOR G-128 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B STRETCHER WAITING G-127 NURSE STATION G-126 ELECTRICAL CLOSET G-125 WAITING ROOM G-119 RECEPTION G-114C CORRIDOR G-119B WAITING ROOM PATIENT TOILET G-119A MEN'S CHANGING & WAITING G-114 PATIENT TOILET G-109 CORRIDOR G-115D CORRIDOR G-115C STEREOTACTIC G-105 NAVIGATOR'S OFFICE G-116 ULTRASOUND G-121MAMMOGRAPHY G-122 EXAM 1 G-106 COPIER RECYCLE WASTEBASKET PURELL SIDE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR WHEELCHAIR TRASH SOAP LOUNGE CHAIR LOUNGE CHAIR WATER LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE SETTEE COFFEE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE MOBILE PED BLACK BOX MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED TASK CHAIR WASTEBASKET RECYCLE TRASH RECYCLE WASTEBASKET SOILED LINEN HAMPER TRASH PAPER SOAP PAPER TRASH SOAP TRASH PHONE PAPER SOAP COAT HOOKS VIEW BOX TRASH PAPER SOAP PHONE PURELL PAPER SOAP PHONE PHONE WASTEBASKET RECYCLE SHARPS SHARPS SHARPS PHONE PHONE GLOVES GLOVESGLOVES PHONE PURELL SOAPPAPER TRASH WASTEBASKET RECYCLE SOAP PAPER PAPER SOAP PAPERSOAP TRASH GLOVESGLOVES SOAP PAPER PAPER PAPER SOAP PHONE TRASH TRASH PHONE COMPUTER COMPUTER PHONE PHONESHARPS SHARPS PHONE COMPUTER COMPUTER SOAP MIRROR, TALL MIRROR, TALL MIRROR, TALL MIRROR, TALL PAPER WATER TRASH TRASH WASTEBASKET PHONE COMPUTER COMPUTER PHONE WASTEBASKET COMPUTER PHONE PHONE TRASH WASTEBASKET RECYCLE RECYCLE RECYCLE TRASH TRASH TRASH COAT HOOKS TRASH UC FRIDGE PHONE COMPUTER STABLERISE STABLERISE SCANNER SCANNER SCANNER CPU CPU CPU SCANNER SCANNER SCANNER CPU CPU CPU OFFICE G-108 CPU CPU 5 6 7 8 910 1112131415 18 19 20 21 22 16 17 25 26 27 28 SL-1 SL-2 EXISTING TECHNOLOGY ROOM 1 3 (TYP.) 2 4 (TYP.) 4 (TYP.) 4 (TYP.) 4 (TYP.) Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:25:42 AMES-101 185-01-00 8/15/16 GROUND FLOOR ELECTRICAL SPECIAL SYSTEMS PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER DRAWING NOTES TIE INTO LOCAL 120V RECEPTACLE EMERGENCY BRANCH CIRCUIT SERVING SUB-WAITING AREA. TIE INTO LOCAL 120V RECEPTACLE EMERGENCY BRANCH CIRCUIT CORRIDOR. NEW PAGING SPEAKERS. REFER TO SPECIFICATION SECTION FOR ADDITIONAL INFORMATION. PROVIDE NEW WIRING FROM SPEAKERS BACK TO EXISTING PAGING AMPLIFIER SYSTEM RACK LOCATED IN THE BASEMENT ESSENTIAL SIDE OF THE P2000 MAIN ELECTRIC ROOM. COORDINATE LOCATION WITH HOSPITAL FACILITIES. PROVIDE NEW AMPLIFIER FOR THIS AREA. SEPARATE EXISTING ROOMS THAT ARE JUST OUTSIDE THE AREA OF SCOPE THAT ARE TIED TO THE ARE BEING RENOVATED AND MAINTAIN ON THEIR EXISTING AMPLIFIER. EXISTING SYSTEM IS NOTIFIER. REVIEW EXISTING CONDITIONS AND COORDINATE DIRECTLY WITH NOTIFIER TECHNICIAN AND HOSPITAL FACILITIES. THE EXISTING ADDRESSABLE LOOP SHALL BE TIED OFF AND MAINTAINED AS IT SERVES THE UPPER FLOORS. INITIATION LOOP FOR THE PROPOSED AREA WITHIN THE SCOPE OF WORK COULD BE TIED INTO THE CANCER CENTER (ONCOLOGY LOOP) RECENTLY COMPLETED. SPEAKERS CAN BE WIRED INTO THE FIRE ALARM CONTROL PANEL LOCATED IN THE BASEMENT ESSENTIAL SIDE OF THE P2000 MAIN ELECTRIC ROOM. PROVIDE AN ALLOWANCE FOR FURNISHING AND INSTALLING A NEW ‘FCPS’ FOR THE STROBE UNITS. THIS CAN BE LOCATED IN THE NEW ELECTRIC CLOSET. 1 2 SCALE: 1/4" = 1'-0"1 GROUND FLOOR ELECTRICAL SPECIAL SYSTEMS PLAN DRAWING NOTESGENERAL NOTES COORDINATE EXACT LOCATION OF ELECTRICAL DEVICES SUCH AS LIGHTING, EXIT SIGNS, SWITCHES, RECEPTACLES, DATA/TEL., FIRE ALARM DEVICES, ETC., WITH ALL DEVICES WITHIN MECHANICAL AND ELECTRICAL ROOMS SHALL BE COORDINATED WITH PANELS, DUCTWORK, PIPING, CONDUIT, ETC. FOR FINAL LOCATIONS. TYPICAL HOMERUN FOR EACH BRANCH CIRCUIT SHALL BE FED BY 2#12,1#12G.,3/4" CONDUIT TO A 20A-1P CIRCUIT BREAKER IN PANELBOARD AS DESIGNATED, UNLESS SHOWN OTHERWISE. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION SYSTEMS IN ABOVE CEILING SPACE TO PERMIT THE PLACEMENT OF LIGHTS, DEVICES, AND SPRINKLER HEADS IN THE EXACT LOCATION SHOWN ON THE ARCHITECTURAL DRAWINGS. 1. 2. 3. 4. GENERAL NOTES 3 4 Issuance Schedule Number Date Description E TX E VISUAL UNIT WITH BUZZER EMERGENCY CALL-FOR-AID. MOUNTED 48" A.F.F. AT TOILET LOCATION. CORD TO EXTEND TO WITHIN 6" OF THE FLOOR NOTES: 1. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. 2. UTILIZE (2) #18 IN RACEWAY FOR ALL WIRING, UNLESS OTHERWISE NOTED. (2) #12 & (1) #12 GND. IN 3/4"C. TO LOCAL 120 VOLT LIGHTING CIRCUIT OR RECEPTACLE CIRCUIT FLOOR CEILING TRANSFORMER 120V/24V, REMOTE MOUNTED ABOVE NEAREST ACCESSIBLE CEILING IN NEMA1 ENCLOSURE HANDICAPPED TOILET CALL FOR AID DETAIL NOT TO SCALE HANDICAPPED TOILET CALL FOR AID DETAIL PANEL DUPLEX POWER RECEPTACLE DETAIL NOTES: 1. ELECTRICAL DEVICE PLATE LABEL OR NAMEPLATE SHALL IDENTIFY THE SOURCE OF POWER TO THE DEVICE. LABELS OR NAMEPLATES SHALL BE AN APPROVED PERMANENT TYPE. LIGHT SWITCH NAMEPLATE OR LABEL CIRCUIT XXX-XX XXX-XX TYPICAL DEVICE LABELING DETAIL NOT TO SCALE DETAIL NOTES: 1. REFER TO SPECIFICATIONS FOR ADDITIONAL NAMEPLATE REQUIREMENTS. 2. NAMEPLATE TO BE 1/16" PLASTIC WITH 1/4" MINIMUM CENTER LETTER LAMINATION. FACE TO BE BLACK WITH WHITE ENGRAVED LETTERS FOR NORMAL POWER; RED WITH WHITE ENGRAVED LETTERS FOR ESSENTIAL POWER. 3. SECURE NAMEPLATE TO SURFACES 3M TAPE OR EQUAL. "HVCB1-ED1" 277/480V., 3∅, 4W FED FROM "DP-CB1-LAB/ED" TYPICAL NAMEPLATE DETAIL SCALE: NTS PANEL NAME PANEL CIRCUIT SM-WING, EM PWR RM-100A TYPICAL DEVICE LABELING DETAIL TYPICAL NAMEPLATE DETAIL TERMINATE RACEWAY WITH PLASTIC BUSHING IN AN ACCESSIBLE LOCATION ABOVE CEILING 8" RADIUS ELBOW CEILING (1) 1" CONDUIT WITH PULL STRING (2) GANG DEEP BACK BOX WITH SINGLE GANG EXTENSION BOX 18" AFF. VERIFY HEIGHT WITH ARCHITECT FLOOR PROVIDE COVER PLATE. FINISH AND COLOR SELECTED BY ARCHITECT UTILIZE THIS DETAIL WHEN ANY OF THE FOLLOWING SYMBOLS ARE SHOWN ON PLAN: NOT TO SCALE TELEPHONE/DATA OUTLET DETAILTELEPHONE/DATA OUTLET DETAIL MSM MSM LOW VOLTAGE 3 #14, 3/4"C. SWITCH 3 WAY LOW VOLTAGE 3 #14, 3/4"C. STATIONSINGLE POLESWITCH ARRANGEMENT3/4"C., 120V 2 #12,+GRD.,ARRANGEMENT3-WAY SWITCHMASTER CONTROL STATION 3/4"C., 120V 2 #12,+GRD., MASTER CONTROL 3 LAMP BALLAST 3 LAMP BALLAST 3 #12,+GRD., OCCUPANCY SENSOR OCCUPANCY SENSOR 3/4"C. SWITCH 3 WAY 2#12,+GRD., SWITCH SINGLE POLE 3/4"C. LIGHTING OCCUPANCY SENSOR NOTES: COORDINATE FINAL WIRING REQUIREMENT OF SENSOR, POWER PACKS, CONTROLLERS WITH MANUFACTURER. SENSOR(S) SHALL REPORT TO THE MASTER CONTROL STATION. PROVIDE LOW VOLTAGE PLENUM RATED WIRING BETWEEN SENSOR AND MASTER STATION PER MANUFACTURER'S REQUIREMENTS. MASTER CONTROL STATION SHALL BE MOUNTED ABOVE CEILING IN AREA BEING SERVED. MASTER CONTROL STATION SHALL TURN ON THE LIGHTING CIRCUIT UPON ACTIVATION OF OCCUPANCY SENSOR. CONTROL STATION SHALL TURN OFF THE LIGHTS WHEN SENSOR HAS DEACTIVATED AND AFTER A PREDETERMINED TIME DELAY. WALL SWITCH(ES), ONLY AS APPLICABLE TO PROJECT, SHALL BE WIRED TO BY-PASS THE SENSOR TURNING THE LIGHTS OFF. COORDINATE SETTINGS FOR SENSORS WITH ARCHITECT AND OWNER. TIME-OUT DELAY SHALL BE SET TO MAXIMUM AS INITIAL SETTING. 1. 2. 3. 4. 5. 6. TYPICAL OCCUPANCY SENSOR WIRING DIAGRAM NOT TO SCALE TYPICAL OCCUPANCY SENSOR WIRING DIAGRAM Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. As indicated 8/16/2016 11:25:29 AME-400 185-01-00 8/15/16 ELECTRICAL DETAILS COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER Issuance Schedule Number Date Description WAP WAP SD DS M SCOPE OF WORK RADIOLOGIST WORKROOM G-124 ULTRASOUND EQUIPMENT TASK CHAIR (EXISTING) STRETCHER STRETCHER BIOPSY TABLE SUCTION DEVICE STERILE SUPPLY CART RED BOX BLACK BOX GUEST CHAIR STEREO MONITOR STAND SOILED LINEN HAMPER SOILED LINEN HAMPER GUEST CHAIR SHARPS EXAM TABLE SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR REFRIDGERATOR SHARPS SOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR SHARPS GLOVES AQUISITION WORKSTATION WHEELCHAIR RED BOX WALL MOUNTED PADDLES SET UP TRAY SUCTION DEVICE C-ARMSOILED LINEN HAMPER GUEST CHAIR GUEST CHAIR 5 MP MONITOR STAND FROM STEREOTATIC LARGE MAMMOGRAPHY G-120 AQUISITION WORKSTATION WHEELCHAIR SET UP TRAY SUCTION DEVICE C-ARM CLEAN WORK AREA G-126A INTERVIEW 2 G-117 PATIENT CHANGING ROOM 3 G-111C TASK CHAIR TASK CHAIRWALL MOUNTED PADDLES LARGE BIOPSY CHAIR PATIENT CHANGING ROOM 1 G-111D PATIENT CHANGING ROOM 2 G-111B STAFF TOILET G-130A TASK CHAIR EXAM 2 G-107 EXAM TABLE SOILED HOLDING ROOM G-112 CHANGING PATIENT TOILET G-111A TASK CHAIR BONE DENSITY G-113 GOWNED SUB-WAITING G-110 SOILED LINEN HAMPER TASK CHAIR GUEST CHAIR GUEST CHAIR TASK CHAIR PRINTER FILM COPIER PRINTER TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR WITHOUT ARMS TASK CHAIR (EXISTING) BONE DENSITY TABLE BONE DENSITY WORKSTATION/CART WHEELCHAIR SCALE SOILED LINEN HAMPER GUEST CHAIR TASK CHAIR (EXISTING) STADIOMETER GLOVES PRINTER, SM SOAP PAPER TOILET PAPER SOAP PAPER TOILET PAPER PAPER SOAP SOILED LINEN BINTOILET PAPER TOILET PAPER COAT HOOKS CODE CART METRO RACK TRAY RACK 5 MP MONITOR STAND STEREO GENERATOR MIRCROWAVE KEURIG PURELL PURELL PURELL PURELL PURELL PURELL PURELLPURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL PURELL RED BOX SHARPS SHARPS TASK CHAIR (EXISTING) PURELL PURELL PURELLPURELL TASK CHAIR TASK CHAIR WITHOUT ARMS BACKERBOARD METRO RACK WOW TRASH STANDING WATER COOLER RECYCLE CONFIDENTIAL RECYCLE MOBILE PED MOBILE PED RADIOLOGIST WORKSTATION (EXISTING) RADIOLOGIST WORKSTATION (EXISTING) PHONE PHONE SIDE TABLE - SMALL TASK CHAIR WITHOUT ARMS STRETCHER ROUND TABLE WITH 4 CHAIRS LOUNGE CHAIR SCANNER SCANNER DESK DESK LOUNGE CHAIR PURELL INTERVIEW 1 G-118 ICE PAPER SOAP TRASH DEFIBRILLATOR SOAP PAPER PRINTER, SM TASK CHAIR STAFF BREAK ROOM G-123 CORRIDOR G-128 TECH WORKROOM G-130 MANAGER'S OFFICE G-130B STRETCHER WAITING G-127 NURSE STATION G-126 ELECTRICAL CLOSET G-125 WAITING ROOM G-119 RECEPTION G-114C CORRIDOR G-119B WAITING ROOM PATIENT TOILET G-119A MEN'S CHANGING & WAITING G-114 PATIENT TOILET G-109 CORRIDOR G-115D CORRIDOR G-115C STEREOTACTIC G-105 NAVIGATOR'S OFFICE G-116 ULTRASOUND G-121MAMMOGRAPHY G-122 EXAM 1 G-106 COPIER RECYCLE WASTEBASKET PURELL SIDE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR WHEELCHAIR TRASH SOAP LOUNGE CHAIR LOUNGE CHAIR WATER LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE SETTEE COFFEE TABLE SETTEE SIDE TABLE LOUNGE CHAIR LOUNGE CHAIR LOUNGE CHAIR SIDE TABLE MOBILE PED BLACK BOX MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED MOBILE PED TASK CHAIR WASTEBASKET RECYCLE TRASH RECYCLE WASTEBASKET SOILED LINEN HAMPER TRASH PAPER SOAP PAPER TRASH SOAP TRASH PHONE PAPER SOAP COAT HOOKS VIEW BOX TRASH PAPER SOAP PHONE PURELL PAPER SOAP PHONE PHONE WASTEBASKET RECYCLE SHARPS SHARPS SHARPS PHONE PHONE GLOVES GLOVESGLOVES PHONE PURELL SOAPPAPER TRASH WASTEBASKET RECYCLE SOAP PAPER PAPER SOAP PAPERSOAP TRASH GLOVESGLOVES SOAP PAPER PAPER PAPER SOAP PHONE TRASH TRASH PHONE COMPUTER COMPUTER PHONE PHONESHARPS SHARPS PHONE COMPUTER COMPUTER SOAP MIRROR, TALL MIRROR, TALL MIRROR, TALL MIRROR, TALL PAPER WATER TRASH TRASH WASTEBASKET PHONE COMPUTER COMPUTER PHONE WASTEBASKET COMPUTER PHONE PHONE TRASH WASTEBASKET RECYCLE RECYCLE RECYCLE TRASH TRASH TRASH COAT HOOKS TRASH UC FRIDGE PHONE COMPUTER STABLERISE STABLERISE SCANNER SCANNER SCANNER CPU CPU CPU SCANNER SCANNER SCANNER CPU CPU CPU OFFICE G-108 CPU CPU 5 6 7 8 910 1112131415 18 19 20 21 22 16 17 25 26 27 28 1 1 1 11 1 1 1 EXISTING TECHNOLOGY ROOM 2 TYP. 1 1 Scale: Date Issued: Project Number: Isgenuity LLC 321 Summer Street, Suite 401 Boston, MA 02210 Tel 617 419 4660 Fax 617 419 4661 www.isgenuity.com Architect NORTH MEP/FP Engineer BVH Integrated Services 50 Griffin Road South Bloomfield, CT 06002 Tel 860 286 9171 Fax 860 242 0236 ISSUED FOR CONSTRUCTION BVH: 21-15-085REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"8/16/2016 11:26:30 AMT-101 185-01-00 8/15/16 GROUND FLOOR TECHNOLOGY PLAN COOLEY DICKINSON HOSPITAL COMPREHENSIVE BREAST CARE CENTER DRAWING NOTES DATA CABLING (TYPE 6A) AND VOICE CABLING (TYPE 5E) SHALL BE RUN BY THE HOSPITAL VENDOR. CONTRACTOR SHALL PROVIDE A CONDUIT WITH PULLWIRE FROM BOX TO ABOVE ACCESSIBLE CEILING. VOICE JUNCTION BOX IN THIS LOCATION SHALL BE AT 45” AFF. DATA CABLING IN THIS LOCATION SHALL BE RUN DOWN TO 18” AFF. REFER TO TYPICAL DETAIL ON ELECTRICAL DRAWINGS. DATA CABLING (TYPE 6A) AND VOICE CABLING (TYPE 5E) SHALL BE RUN BY THE HOSPITAL VENDOR. CONTRACTOR SHALL PROVIDE A CONDUIT WITH PULLWIRE FROM BOX TO ABOVE ACCESSIBLE CEILING. DATA/VOICE JUNCTION BOX SHALL BE MOUNTED AT 18” AFF. REFER TO TYPICAL DETAIL ON ELECTRICAL DRAWINGS. 1 2 SCALE: 1/4" = 1'-0"1 GROUND FLOOR TECHNOLOGY PLAN DRAWING NOTESGENERAL NOTES COORDINATE EXACT LOCATION OF ELECTRICAL DEVICES SUCH AS LIGHTING, EXIT SIGNS, SWITCHES, RECEPTACLES, DATA/TEL., FIRE ALARM DEVICES, ETC., WITH ALL DEVICES WITHIN MECHANICAL AND ELECTRICAL ROOMS SHALL BE COORDINATED WITH PANELS, DUCTWORK, PIPING, CONDUIT, ETC. FOR FINAL LOCATIONS. TYPICAL HOMERUN FOR EACH BRANCH CIRCUIT SHALL BE FED BY 2#12,1#12G.,3/4" CONDUIT TO A 20A-1P CIRCUIT BREAKER IN PANELBOARD AS DESIGNATED, UNLESS SHOWN OTHERWISE. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION SYSTEMS IN ABOVE CEILING SPACE TO PERMIT THE PLACEMENT OF LIGHTS, DEVICES, AND SPRINKLER HEADS IN THE EXACT LOCATION SHOWN ON THE ARCHITECTURAL DRAWINGS. 1. 2. 3. 4. GENERAL NOTES Issuance Schedule Number Date Description