Loading...
tower repairs 800530 - Final Design 2014-10-21 September 18, 2014 162 Ft Monopole Tower Structural Analysis CCI BU No 800530 Project Number 003-14-0971, Application 262654, Revision 1 Page 24 tnxTower Report - version 6.1.4.1 APPENDIX D MODIFICATION DRAWINGS PREPARED FOR CROWN CASTLE 00 PREMISSION OF CROWN CASTLE. THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF CROWN CASTLE. IT IS PRODUCED SOLELY FOR USE BY CROWN AND ITS AFFILILATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN BU 9/19/2014 D A B C D 345678 8 7 6 5 4 3 2 1 E F E F S-1 00 TITLE PAGE . NO.DATE DESCRIPTION BY REVISIONS ENG/QA BY: DFT BY: DFT/QA BY: APRV'D BY: SCALE: N.T.S. DATE: DATE: DATE: DATE: REV SITE NAME: BU NUMBER: WO NUMBER: SITE ADDRESS: ATWOOD DRIVE SC 9/19/2014 9/19/2014 CAC800530 929528 HAMPSHIRE COUNTY NORTHAMPTON, MA 01060 9/19/14 INITIAL RELEASE MB MB SC MA NORTHAMPTON II 9/19/2014 S-5 PREPARED FOR CROWN CASTLE ELEVATION CAC HAMPSHIRE COUNTY SHEET NUMBER ATWOOD DRIVE NORTHAMPTON, MA 01060 S-3 MA NORTHAMPTON II 800530 SITE ADDRESS: BU NUMBER: SITE NAME: TIGHTENING PROCEDURE NOTES S-4 MODIFICATION INSPECTION CHECKLIST Northampton, MA 01060 TITLE PAGE S-2 S-1 DRAWINGS INCLUDED AJAX/DTI BOLT SPECIFICATIONS AND DESCRIPTIONBoston Logan International Airport1 Harborside Dr, Boston, MA 02128 Head southeast on Airport Rd - Departure Level toward Airport Rd Terminal C 0.6 miTake the Interstate 90 W/Williams Tunnel/Mass Pike ramp to Boston/Interstate 93 S Toll road 0.6 miMerge onto I-90 W Partial toll road 90.9 miTake the exit toward I-91 N Toll road 0.3 miKeep left at the fork, follow signs for I-91 N/Holyoke and merge onto I-91 N Partial toll road 11.7 miTake exit 18 to merge onto US-5 S/Mt Tom Rd 0.2 miMerge onto US-5 S/Mt Tom Rd 331 ftTurn right onto Atwood Dr 1 Atwood Dr MONOPOLE REINFORCEMENT DRAWINGS 1 2 3 AERODESIGNENGINEER(EOR) PROJECTCONTACTS AndrewBazinet 720Ͳ304Ͳ6882 scook@aerosolutionsllc.com 5500FLATIRONPKWY,SUITE100 BOULDER,CO80301 ShawnD.Cook,P.E. 585Ͳ899Ͳ3442 Andrew.Bazinet@crowncastle.com 3CorporateParkDrive,Suite101 CliftonPark,NY12065 CROWNTOWERSTRUCTURALANALYST CROWNPROJECTMANAGER JerryBruno 781Ͳ970Ͳ0069 Jerry.Bruno.Contractor@crowncastle.com 60MPH CEXPOSURECATEGORY: TIACODE: WINDSPEEDNOICE: ICETHICKNESS: WINDSPEEDWITHICE: SERVICELOADS: THISREINFORCEMENTDESIGNISBASEDONTHEREQUIREMENTSOFTIA STRUCTURALSTANDARDSFORSTEELANTENNATOWERSANDANTENNA SUPPORTINGSTRUCTURESUSING 100MPH3ͲSEC.GUSTWINDSPEED 1" 40MPH CODECOMPLIANCE TIAͲ222ͲG 162 FT MONOPOLETOWER LAT: LONG: TOWERINFORMATION 262654R1 42.3027 Ͳ72.6252 EngineeredEndeavorsInc.TOWERMANUFACTURER: TOWERHEIGHT/TYPE: TOWERLOCATION: APPLICATIONID: MODIFICATION INSPECTION NOTES . MI VERIFICATION INSPECTIONS ” REPORT FOR THE ORIGINAL PROJECT. WEATHER OR OTHER CONDITIONS THAT MAY COMPROMISE THE SAFETY OF THE PARTIES INVOLVED.FOR A THIRD PARTY MI, EXCEPTIONS MAY BE MADE IN THE EVENT THAT THE DELAY/CANCELLATION IS CAUSED BY CANCELLATION OR DELAYS IN SCHEDULED MI (E.G. TRAVEL AND LODGING, COSTS OF KEEPING EQUIPMENT ON-SITE, ETC.). IF CROWN CONTRACTS DIRECTLYOTHER PENALTIES RELATED TO THE CANCELLATION OR DELAY INCURRED BY EITHER PARTY, NOR FOR ANY TIMECANCELS OR DELAYS, CROWN SHALL NOT BE RESPONSIBLE FOR ANY COSTS, FEES, LOSS OF DEPOSITS AND/ORIF THE GC AND MI INSPECTOR AGREE TO A DATE ON WHICH THE MI WILL BE CONDUCTED, AND EITHER PARTY WELD PREPARATIONxx xxPHOTOS OF ALL CRITICAL DETAILSxxFOUNDATION MODIFICATIONS BOLT INSTALLATIONxxFINAL INSTALLED CONDITION xx IF THE MODIFICATION INSTALLATION WOULD FAIL THE MI (“FAILED MI”), THE GC SHALL WORK WITH CROWN TO COORDINATE A REMEDIATION PLAN IN ONE OF TWO WAYS: WHEN THE MI INSPECTOR IS ON SITE. COORDINATE THE MI CAREFULLY TO ENSURE ALL CONSTRUCTION FACILITIES ARE AT THEIR DISPOSAL RECOMMENDATIONS ANY DEFICIENCIES CORRECTED DURING THE INITIAL MI. THEREFORE, THE GC MAY CHOOSE TO WHEN POSSIBLE, IT IS PREFERRED TO HAVE THE GC AND MI INSPECTOR ON-SITE DURING THE MI TO HAVEx INSPECTIONS TO ALLOW THE FOUNDATION AND MI INSPECTION(S) TO COMMENCE WITH ONE SITE VISIT. IT MAY BE BENEFICIAL TO INSTALL ALL TOWER MODIFICATIONS PRIOR TO CONDUCTING THE FOUNDATIONx ANY GUY WIRE TENSIONING OR RE-TENSIONING OPERATIONS. WHEN POSSIBLE, IT IS PREFERRED TO HAVE THE GC AND MI INSPECTOR ON-SITE SIMULTANEOUSLY FORx REQUIREMENTS OF THE MI CHECKLIST AND CROWN ENG-SOW-10007. THE GC SHALL PERFORM AND RECORD THE TEST AND INSPECTION RESULTS IN ACCORDANCE WITH THE GENERAL CONTRACTOR BETTER UNDERSTAND ALL INSPECTION AND TESTING REQUIREMENTSx INCLUDING FOUNDATION INSPECTIONS WORK WITH THE MI INSPECTOR TO DEVELOP A SCHEDULE TO CONDUCT ON-SITE MI INSPECTIONS,xREVIEW THE REQUIREMENTS OF THE MI CHECKLISTx INSTALLATION OR TURNKEY PROJECT TO, AT A MINIMUM: SUBMITTING THE MI REPORT TO CROWN. DOCUMENTS FOR ADHERENCE TO THE CONTRACT DOCUMENTS, CONDUCTING THE IN-FIELD INSPECTIONS, AND MI INSPECTOR THE MI INSPECTOR IS RESPONSIBLE FOR COLLECTING ALL GC INSPECTION AND TEST REPORTS, REVIEWING THE FOUNDATION INSPECTIONS WORK WITH THE GC TO DEVELOP A SCHEDULE TO CONDUCT ON-SITE INSPECTIONS, INCLUDINGxREVIEW THE REQUIREMENTS OF THE MI CHECKLISTx MINIMUM: THE MI INSPECTOR IS REQUIRED TO CONTACT THE GC AS SOON AS RECEIVING A PO FOR THE MI TO, AT A THE GC IS REQUIRED TO CONTACT THE MI INSPECTOR AS SOON AS RECEIVING A PO FOR THE MODIFICATION THE GC AND MI INSPECTOR COORDINATE CLOSELY THROUGHOUT THE ENTIRE PROJECT.x MI INSPECTOR AS TO WHEN THE SITE WILL BE READY FOR THE MI TO BE CONDUCTED. IT IS SUGGESTED THAT THE GC PROVIDE A MINIMUM OF 5 BUSINESS DAYS NOTICE, PREFERABLY 10, TO THEx EFFECTIVENESS OF DELIVERING AN MI REPORT: REQUIREMENTS. REFER TO CROWN ENG-SOW-10007, "MODIFICATION INSPECTION SOW", FOR FURTHER DETAILS AND GENERAL REQUIRED PHOTOS IF CONTACT INFORMATION IS NOT KNOWN, CONTACT YOUR CROWN POINT OF CONTACT (POC). RECEIVED. IT IS EXPECTED THAT EACH PARTY WILL BE PROACTIVE IN REACHING OUT TO THE OTHER PARTY. AND THE MI INSPECTOR BEGIN COMMUNICATING AND COORDINATING AS SOON AS A PURCHASE ORDER ( PO) IS TO ENSURE THAT THE REQUIREMENTS OF THE MI ARE MET, IT IS VITAL THAT THE GENERAL CONTRACTOR (GC) "APPROVED MI VENDORS". (AESV) THAT IS APPROVED TO PERFORM ELEVATED WORK FOR CROWN. SEE CROWN ENG-BUL-10173, ALL MI'S SHALL BE CONDUCTED BY A CROWN ENGINEERING VENDOR (AEV) OR ENGINEERING SERVICE VENDOR EOR AT ALL TIMES. OWNERSHIP OF THE STRUCTURAL MODIFICATION DESIGN EFFECTIVENESS AND INTEGRITY RESIDES WITH THEMODIFICATION DESIGN ITSELF, NOR DOES THE MI INSPECTOR TAKE OWNERSHIP OF THE MODIFICATION DESIGN. THE MI IS TO CONFIRM INSTALLATION CONFIGURATION AND WORKMANSHIP ONLY AND IS NOT A REVIEW OF THE ENGINEER OF RECORD (EOR). ACCORDANCE WITH THE CONTRACT DOCUMENTS, NAMELY THE MODIFICATION DRAWINGS, AS DESIGNED BY THE CONSTRUCTION INSPECTIONS AND OTHER REPORTS TO ENSURE THE INSTALLATION WAS CONSTRUCTED IN THE MODIFICATION INSPECTION (MI) IS A VISUAL INSPECTION OF TOWER MODIFICATIONS AND A REVIEW OF THE FOLLOWING RECOMMENDATIONS AND SUGGESTIONS ARE OFFERED TO ENHANCE THE EFFICIENCY AND xCORRECT FAILING ISSUES TO COMPLY WITH THE SPECIFICATIONS CONTAINED IN THE ORIGINAL CONTRACT DOCUMENTS AND COORDINATE A SUPPLEMENT MI.x CORRECTION OF FAILING MI'S OR, WITH CROWN'S APPROVAL, THE GC MAY WORK WITH THE EOR TO RE-ANALYZE THE MODIFICATION/REINFORCEMENT USING THE AS-BUILT CONDITION THIS IS NOT A COMPLETE LIST OF REQUIRED PHOTOS, PLEASE REFER TO CROWN ENG-SOW-10007. PHOTOS OF ELEVATED MODIFICATIONS TAKEN ONLY FROM THE GROUND SHALL BE CONSIDERED INADEQUATE. FINAL INFIELD CONDITIONxx POST CONSTRUCTION PHOTOGRAPHSxSURFACE COATING REPAIRxx BETWEEN THE GC AND THE MI INSPECTOR THE FOLLOWING PHOTOGRAPHS, AT A MINIMUM, ARE TO BE TAKEN AND INCLUDED IN THE MI REPORT: xPRE-CONSTRUCTION GENERAL SITE CONDITIONxPHOTOGRAPHS DURING THE REINFORCEMENT MODIFICATION CONSTRUCTION/ERECTION AND INSPECTIONxxRAW MATERIALS CROWN RESERVES THE RIGHT TO CONDUCT AN MI VERIFICATION INSPECTION TO VERIFY THE ACCURACY AND COMPLETENESS OF PREVIOUSLY COMPLETED MI INSPECTION(S) ON TOWER MODIFICATION PROJECTS. ALL VERIFICATION INSPECTIONS SHALL BE HELD TO THE SAME SPECIFICATIONS AND REQUIREMENTS IN THE CONTRACT DOCUMENTS AND IN ACCORDANCE WITH CROWN ENG-SOW-10007. VERIFICATION INSPECTION MAY BE CONDUCTED BY AN INDEPENDENT AEV/AESV FIRM AFTER A MODIFICATIONPROJECT IS COMPLETED, AS MARKED BY THE DATE OF AN ACCEPTED “PASSING MI” OR “PASS AS NOTED MI NOTE: X DENOTES A DOCUMENT REQUIRED FOR THE MI REPORT NA DENOTES A DOCUMENT THAT IS NOT REQUIRED FOR THE MI REPORT PREPARED FOR CROWN CASTLE 00 PREMISSION OF CROWN CASTLE. THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF CROWN CASTLE. IT IS PRODUCED SOLELY FOR USE BY CROWN AND ITS AFFILILATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN BU 9/19/2014 D A B C D 345678 8 7 6 5 4 3 2 1 E F E F S-2 00 9/19/2014 SC CHECKLIST . NO.DATE DESCRIPTION BY REVISIONS ENG/QA BY: DFT BY: DFT/QA BY: APRV'D BY: SCALE: N.T.S. DATE: DATE: DATE: DATE: REV SITE NAME: BU NUMBER: WO NUMBER: SITE ADDRESS: ATWOOD DRIVE SC 9/19/2014 INSPECTION CAC800530 929528 HAMPSHIRE COUNTY NORTHAMPTON, MA 01060 9/19/14 INITIAL RELEASE MB MB MODIFICATION MA NORTHAMPTON II 9/19/2014 CONSTRUCTION / INSTALLATION INSPECTIONS AND TESTING REQUIRED (COM PLETED BY EOR) REPORT ITEM X X X NA NA ADDITIONAL TESTING AND INSPECTIONS: X NA X NA NA X CONCRETE COMP. STRENGTH AND SLUMP TESTS X X NA NA NA NA NA X NA POST INSTALLED ANCHOR ROD VERIFICATION CONSTRUCTION MI CHECKLIST DRAWING EOR APPROVAL FABRICATION INSPECTION FABRICATOR CERTIFIED WELD INSPECTION M ATERIAL TEST REPORT (M TR) FABRICATOR NDE INSPECTION NDE REPORT OF M ONOPOLE BASE PLATE PER ENG-SOW-10033 PACKING SLIPS X MI INSPECTOR REDLINE OR RECORD DRAWING (S) POST INSTALLED ANCHOR ROD PULL OUT TESTING PHOTOGRAPHS MI CHECKLIST PRE-CONSTRUCTION ADDITIONAL TESTING AND INSPECTIONS: None None None ADDITIONAL TESTING AND INSPECTIONS: POST CONSTRUCTION BASE PLATE GROUT VERIFICATION CONTRACTORS CERTIFIED WELD INSPECTION AND NDE REPORTS EARTHWORK LIFT AND DENSITY ON SITE COLD GALVANIZING VERIFICATION GUY WIRE TENSION REPORT GC AS BUILT DOCUMENTS CONSTRUCTION INSPECTIONS FOUNDATION INSPECTIONS DETAIL DRAWINGS SHALL GOVERN OVER ANY VARIANCE FROM THIS SHEET GENERAL NOTES 1. ALL WORK PRESENTED ON THESE DRAWINGS MUST BE COMPLETED BY THE CONTRACTOR UNLESS NOTED OTHERWISE. THE CONTRACTOR MUST BE EXPERIENCED IN THE PERFORMANCE OF WORK SIMILAR TO THAT DESCRIBED HEREIN. BY ACCEPTANCE OF THIS ASSIGNMENT, THE CONTRACTOR IS ATTESTING THAT HE DOES HAVE SUFFICIENT EXPERIENCE AND ABILITY, THAT HE IS KNOWLEDGEABLE OF THE WORK TO BE PERFORMED, THAT HE IS PROPERLY LICENSED, AND THAT HE IS PROPERLY REGISTERED TO DO THIS WORK IN THE STATE AND/OR COUNTY IN WHICH IT IS TO BE PERFORMED. 2. THE GENERAL NOTES AND TYPICAL DETAILS ARE APPLICABLE TO ALL PARTS OF THE STRUCTURE AND SHALL BE READ IN CONJUNCTION WITH THE STRUCTURAL DRAWINGS AND PROJECT SPECIFICATIONS. 3. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING APPROVALS FROM ALL AUTHORITIES HAVING JURISDICTION FOR THIS PROJECT AND SHALL NOTIFY THE APPLICABLE JURISDICTIONAL (STATE, COUNTY, OR CITY) ENGINEER 24 HOURS PRIOR TO THE BEGINNING OF CONSTRUCTION. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ABIDING BY ALL CONDITIONS AND REQUIREMENTS OF THE PERMITS. 5. ERECT GUARDS AND BARRIERS PER APPLICABLE LABOR AND CONSTRUCTION SAFETY REGULATIONS. 6. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS, POSSIBLE INTERFERENCES, AND DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT ANY AND ALL DISCREPANCIES TO THE ENGINEER OF RECORD (EOR) AND FIELD PERSONNEL IMMEDIATELY. ANY AND ALL FIELD CHANGES SHALL BE APPROVED AND DOCUMENTED BY THE EOR PRIOR TO FIELD IMPLEMENTATION. 7. ALL MATERIALS AND WORKMANSHIP SHALL BE WARRANTED FOR TWO (2) YEARS FROM THE DATE OF COMPLETED CONSTRUCTION. 8. USE ONLY THE LATEST ISSUES OF ANY APPLICABLE CODES, STANDARDS, OR REGULATIONS MENTIONED IN THE FOLLOWING NOTES AND SPECIFICATIONS, UNO. 9. ALL WORKMANSHIP SHALL BE IN ACCORDANCE WITH ANSI, ASTM, ACI, TIA, AND AISC STANDARDS AS REFERENCED IN THE APPLICABLE CODE. 10. STRUCTURAL ELEMENTS SHOWN ON THESE DRAWINGS ARE DESIGNED IN ACCORDANCE WITH APPLICABLE BUILDING CODES/STANDARDS. ALL CONSTRUCTION, EXCEPT WHERE NOTED OTHERWISE, SHALL COMPLY WITH THOSE CODES/STANDARDS. 11. ALL MATERIALS AND EQUIPMENT FURNISHED SHALL BE NEW AND OF GOOD QUALITY, FREE FROM FAULTS AND DEFECTS, AND IN CONFORMANCE WITH THE DRAWINGS. ANY AND ALL SUBSTITUTIONS MUST BE DULY APPROVED AND AUTHORIZED IN WRITING BY THE OWNER AND ENGINEER OF RECORD PRIOR TO FABRICATION AND INSTALLATION. THE CONTRACTOR SHALL FURNISH SATISFACTORY EVIDENCE AS TO THE KIND AND QUALITY OF THE MATERIALS AND EQUIPMENT BEING SUBSTITUTED. 12. ALL MANUFACTURER'S HARDWARE ASSEMBLY INSTRUCTIONS SHALL BE FOLLOWED EXACTLY AND SHALL SUPERSEDE ANY CONFLICTING NOTES ENCLOSED HEREIN. 13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. THE CONTRACTOR IS ALSO RESPONSIBLE FOR ENSURING THAT ALL CONSTRUCTION PROCEDURES MEET THE REQUIREMENTS OF OSHA, THE OWNER, AND ALL OTHER APPLICABLE LOCAL, STATE, AND FEDERAL SAFETY REGULATIONS. 14. ACCESS TO THE PROPOSED WORK SITE MAY BE RESTRICTED. THE CONTRACTOR SHALL COORDINATE INTENDED CONSTRUCTION ACTIVITY, INCLUDING WORK SCHEDULE AND MATERIAL ACCESS, WITH THE RESIDENT LEASING AGENT. 15. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO SAFEGUARD ALL EXISTING STRUCTURES OR BURIED SERVICES AFFECTED BY THIS CONSTRUCTION. CONTRACTOR IS ALSO RESPONSIBLE FOR TEMPORARILY RELOCATING ANY LINES OR STRUTS AS NECESSARY TO COMPLETE THE REQUIRED WORK. 16. STRUCTURAL DESIGN IS FOR THE COMPLETE CONDITION ONLY. THE CONTRACTOR MUST BE COGNIZANT THAT THE REMOVAL OF ANY STRUCTURAL COMPONENT OF AN EXISTING TOWER HAS THE POTENTIAL TO CAUSE THE PARTIAL OR COMPLETE COLLAPSE OF THE STRUCTURE. ALL NECESSARY PRECAUTIONS MUST BE TAKEN TO ENSURE STRUCTURAL INTEGRITY, INCLUDING, BUT NOT LIMITED TO, ENGINEERING ASSESSMENT OF CONSTRUCTION STRESSES WITH INSTALLATION MAXIMUM WIND SPEED AND/OR TEMPORARY BRACING AND SHORING. 17. DO NOT SCALE DRAWINGS. 18. FOR THIS ANALYSIS AND MODIFICATION, THE TOWER HAS BEEN ASSUMED TO BE IN GOOD CONDITION WITHOUT ANY DEFECTS. IF THE CONTRACTOR DISCOVERS ANY INDICATION OF AN EXISTING STRUCTURAL DEFECT, CONTACT THE ENGINEER OF RECORD IMMEDIATELY. 19. MODIFICATION WORK SHALL BE COMPLETED IN CALM WIND CONDITIONS / OR APPROPRIATE WIND SPEED FOR THE TYPE OF MODIFICATION WORK TO BE INSTALLED. 20. THE CLIMBING FACILITIES, SAFETY CLIMB AND ALL PARTS THEREOF SHALL NOT BE IMPEDED, MODIFIED OR ALTERED WITHOUT THE EXPRESS APPROVAL OF THE ENGINEER OF RECORD. STRUCTURAL STEEL NOTES 1. DESIGN, FABRICATION, ERECTION, ALTERATION AND MAINTENANCE SHALL CONFORM TO THE FOLLOWING, UNLESS NOTED OTHERWISE (UNO). A. TIA-222: STRUCTURAL STANDARD FOR ANTENNA SUPPORTING STRUCTURES AND ANTENNAS B. TIA-1019-A: INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS C. AISC: MANUAL OF STEEL CONSTRUCTION 2. ALL STRUCTURAL ELEMENTS SHALL CONFORM TO THE FOLLOWING REQUIREMENTS, UNO. A. STRUCTURAL STEEL, ASTM A572 GRADE 65 (FY = 65KSI). B. ALL BOLTS, ASTM A325 TYPE 1 GALVANIZED HIGH STRENGTH BOLTS. C. ALL NUTS, ASTM A563 CARBON AND ALLOY STEEL NUTS. D. ALL WASHERS, ASTM F436 HARDENED STEEL WASHERS. 3. HOLES SHALL NOT BE FLAME CUT THRU STEEL UNLESS APPROVED BY THE ENGINEER OF RECORD. 4. ALL FASTENERS SHALL NOT BE REUSED. 5. A NUT LOCKING DEVICE SHALL BE INSTALLED ON ALL PROPOSED AND/OR REPLACED ASTM A325 BOLTS. 6. ALL PROPOSED AND/OR REPLACED BOLTS SHALL BE OF SUFFICIENT LENGTH SUCH THAT THE END OF THE BOLT BE AT LEAST FLUSH WITH THE FACE OF THE NUT. IT IS NOT PERMITTED FOR THE BOLT END TO BE BELOW THE FACE OF THE NUT AFTER TIGHTENING IS COMPLETED. 7. HOT-DIP GALVANIZE ALL ITEMS, UNO. GALVANIZE PER ASTM A123, ASTM A153/A153M OR ASTM A653 G90, AS APPLICABLE. 8. FOR A LIST OF CROWN APPROVED COLD GALVANIZING COMPOUNDS, REFER TO CROWN ENG-BUL-10149, "TOWER PROTECTIVE COATINGS BULLETIN". 9. AFTER FINAL INSPECTION, ALL EXPOSED STRUCTURAL STEEL AS THE RESULT OF THIS SCOPE OF WORK INCLUDING WELDS, FIELD DRILLED HOLES, AND SHAFT INTERIORS (WHERE ACCESSIBLE), SHALL BE CLEANED AND COLD GALVANIZING APPLIED BY BRUSH IN ACCORDANCE WITH CROWN ENG-BUL-10149, "TOWER PROTECTIVE COATINGS BULLETIN". PHOTO DOCUMENTATION IS REQUIRED TO BE SUBMITTED TO THE MI INSPECTOR. 1. ALL WELDING SHALL BE IN ACCORDANCE WITH THE AWS D1.1/D1.1M, "STRUCTURAL WELDING CODE-STEEL". 2. ALL WELDING SHALL BE PERFORMED BY AWS CERTIFIED WELDERS. 3. ALL ARC WELDING ON CROWN STRUCTURES SHALL BE DONE IN ACCORDANCE WITH THE CROWN ENG-PLN-10015, "CUTTING AND WELDING SAFETY PLAN" AND AWS D1.1 (LATEST EDITION). THIS SHALL INCLUDE A CERTIFIED WELDING INSPECTOR (CWI) FOR ACCEPTANCE OR REJECTION OF ALL WELDING OPERATIONS, PRE-DURING-POST, USING THE ACCEPTANCE CRITERIA OF AWS D1.1. THE CWI SHALL WORK WITH THE GC ON THE LEVEL OF INTERACTION NEEDED TO CONDUCT THE WELDING INSPECTION. THE CERTIFIED WELDING INSPECTION IS THE RESPONSIBILITY OF THE GC. 4. FOR ALL WELDING, USE E80XX ELECTRODES FOR SMAW PROCESS AND E8XT-XX ELECTRODES FOR FCAW PROCESS, UNO. 5. SURFACES TO BE WELDED SHALL BE FREE FROM SCALE, SLAG, RUST, MOISTURE, GREASE OR ANY OTHER FOREIGN MATERIAL THAT WOULD PREVENT PROPER WELDING. GRIND THE SURFACE ADJACENT TO THE WELD FOR A DISTANCE OF 2" MINIMUM ALL AROUND. ENSURE BOTH AREAS ARE 100% FREE OF ALL GALVANIZING. 6. DO NOT WELD IF THE TEMPERATURE OF THE STEEL IN THE VICINITY OF THE WELD AREA IS BELOW 0° F. WHEN THE TEMPERATURE IS BETWEEN 0° F AND 32° F, PREHEAT AND MAINTAIN THE STEEL IN THE VICINITY OF THE WELD AREA AT 70° F DURING THE WELDING PROCESS. 7. DO NOT WELD ON WET OR FROST-COVERED SURFACES & PROVIDE ADEQUATE PROTECTION FROM HIGH WINDS. 8. FULL PENETRATION WELDS IN THE VICINITY OF THE BASE OF THE TOWER ARE REQUIRED TO BE 100% NDE INSPECTED BY UT IN ACCORDANCE WITH AWS D1.1. 9. PARTIAL PENETRATION AND FILLET WELDS IN THE VICINITY OF THE BASE OF THE TOWER ARE REQUIRED TO BE 50% NDE INSPECTED BY MP IN ACCORDANCE WITH AWS D1.1. WELDING NOTES 00 THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF CROWN CASTLE. IT IS PRODUCED SOLELY FOR USE BY CROWN AND ITS AFFILILATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PREMISSION OF CROWN CASTLE. PREPARED FOR CROWN CASTLE BU D A B C D 345678 8 7 6 5 4 3 2 1 E F E F S-3 00 NOTES . NO.DATE DESCRIPTION BY REVISIONS ENG/QA BY: DFT BY: DFT/QA BY: APRV'D BY: SCALE: N.T.S. DATE: DATE: DATE: DATE: REV SITE NAME: BU NUMBER: WO NUMBER: SITE ADDRESS: ATWOOD DRIVE SC 9/19/2014 MA NORTHAMPTON II CAC800530 929528 HAMPSHIRE COUNTY NORTHAMPTON, MA 01060 9/19/14 INITIAL RELEASE MB MB SC 9/19/2014 9/19/2014 9/19/2014 00 THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF CROWN CASTLE. IT IS PRODUCED SOLELY FOR USE BY CROWN AND ITS AFFILILATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PREMISSION OF CROWN CASTLE. PREPARED FOR CROWN CASTLE BU D A B C D 345678 8 7 6 5 4 3 2 1 E F E F S-4 00 AJAX/DTI BOLT SPECIFICATIONS AND TIGHTENING PROCEDURE . NO.DATE DESCRIPTION BY REVISIONS ENG/QA BY: DFT BY: DFT/QA BY: APRV'D BY: SCALE: N.T.S. DATE: DATE: DATE: DATE: REV SITE NAME: BU NUMBER: WO NUMBER: SITE ADDRESS: ATWOOD DRIVE SC 9/19/2014 MA NORTHAMPTON II CAC800530 929528 HAMPSHIRE COUNTY NORTHAMPTON, MA 01060 9/19/14 INITIAL RELEASE MB MB SC 9/19/2014 9/19/2014 9/19/2014 RUBBER WASHER(1-1/16" OD X 13/16" ID X 1/8" THICKNESS BOLT: AJAX ONESIDE୶୯ BLIND BOLT (M8.8; EQUIVALENT TO A325) FINISH: HOT DIP GALVANIZED PER ASTM A153. SPLIT WASHER: AJAX ONESIDE୶୯ SPLIT WASHER FINISH: HOT DIP GALVANIZED PER ASTM A153. SHEAR SLEEVE: Fu = 120 KSI MIN. (ASTM A519) 29MM O.D. x 20MM I.D. LENGTH = NOMINAL [GRIP-6MM] = [GRIP-0.25"] (TOL. -0", +1/32") SLEEVES SHALL BE ROUND, WITH ENDS CUT SQUARE AND DEBURRED. FINISH: GALVANIZED (COLD GALVANIZED AS PER CROWN ENG-BUL-10149, HOT DIP GALVANIZED PER ASTM A123, MECHANICALLY GALVANIZED AND SPUN) OR CADMIUM PLATED. SOLID WASHER: AJAX ONESIDE୶୯ SOLID WASHER FINISH: HOT DIP GALVANIZED PER ASTM A153. DIRECT TENSION INDICATOR WASHER:SQUIRTER® DTI, ASTM F959MFINISH: COLD MECHANICALLY GALVANIZED (TO ASTM B695) AND EPOXY COATED. MANUFACTURER:APPLIED BOLTING TECHNOLOGY PRODUCTS, INC.1413 ROCKINGHAM ROAD, BELLOWS FALLS, VERMONT, USA 05101PHONE: 1-800-552-1999WEBSITE: WWW.APPLIEDBOLTING.COM DISTRIBUTORS OF SQUIRTER® DTI'S:http://www.appliedbolting.com/applied-bolting-distributors.html FLAT WASHER:HARDENED FLAT WASHER, ASTM F436M (MINIMUM HARDNESS RC38)FINISH: COLD MECHANICALLY GALVANIZED HEX NUT:AJAX ONESIDE୶୯ HEAVY HEX NUTFINISH: HOT DIP GALVANIZED PER ASTM A153. BOLT ASSEMBLY AND INSTALLATION: BOLT ASSEMBLY SHALL ADHERE TO THE REQUIREMENTS OF DETAIL 1.NON-PETROLEUM BASED, WATER SOLUBLE, INERT BOLT LUBRICANT SHALL BE USED ON ALL AJAX BOLTS TO ENSURE PROPER TENSIONING OF THE ASSEMBLY. CARE SHOULD BETAKEN TO ENSURE THE BOLT HEAD AND SPLIT WASHER ARE NOT LUBRICATED AS THIS MAY CAUSE EXCESSIVE BOLT SLIPPAGE UPON APPLYING TORQUE, WHICH MAY LEAD TODIFFICULTIES IN ENGAGING THE SQUIRTER® DTI WASHER PROPERLY. NOTE: ONLY LUBRICATING THE THREADS OF THE NUT MAY ACHIEVE BETTER RESULTS.THE TYPICAL RULE OF THUMB WHEN USING AN IMPACT WRENCH IS TO ENGAGE FOR NO MORE THAN 10 SECONDS. IF THE BOLT IS NOT SPINNING AND THE SQUIRTERHAVE NOT ENGAGED AFTER 10 SECONDS USING AN IMPACT WRENCH, REMOVE THE NUT AND REAPPLY LUBRICANT. NOTE: PROLONGED USE OF THE IMPACT WRENCH TENDS TOHEAT THE BOLT THREAD/NUT, THEREBY, INCREASING FRICTION ON THE THREADS WHICH WOULD REQUIRE ADDITIONAL TORQUE. HOLDING FOR LONGER THAN 10 SECONDS CAN BECOUNTERPRODUCTIVE. A MINIMUM OF 4 OUT OF 5 SQUIRTER® DTI “BUMPS” SHALL BE ENGAGED IN ANY AJAX/DTI BOLT ASSEMBLY IN THE END CONNECTION OF REINFORCING MEMBERS. INTERMEDIATEBOLTS SHALL ENGAGE A MINIMUM OF 3 OUT OF 5 SQUIRTER® DTI “BUMPS”. DTI WASHERS MUST BE PLACED DIRECTLY AGAINST THE OUTER AJAX WASHER WITH THE "BUMPS" FACING AWAY FROM THE AJAX WASHER. PLACE A HARDENED WASHER BETWEENTHE DTI AND THE AJAX NUT. THE DTI "BUMPS" SHALL BEAR AGAINST THE UNDERSIDE OF A HARDENED FLAT WASHER, NEVER DIRECTLY AGAINST THE NUT. FOLLOW THE DTI MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION, LUBRICATION, TIGHTENING, AND INSPECTION. INSPECTION:VISUALLY INSPECT ALL BOLT ASSEMBLIES TO ENSURE THE MINIMUM “BUMP” ENGAGEMENT AS DEFINED IN THE SECTION “BOLT ASSEMBLY AND INSTALLATION” HAS BEEN ACHIEVED.FOR MORE INFORMATION ON INSPECTION, SEE THE MANUFACTURER'S GUIDELINES.WHERE FEASIBLE, CHECK A SAMPLE OF THE END CONNECTION DTI WASHERS WITH THE APPROPRIATE FEELER GAGE. IF THE FEELER GAGE CANNOT BE INSERTED TO THE BOLTSHANK HALF WAY AROUND THE BOLT, THE INSTALLATION IS OKAY. IF YOU CAN INSERT THE FEELER GAGE TO THE SHANK ALL THE WAY AROUND THE BOLT, THE INSTALLATION ISNOT OKAY. IF YOU FIND MORE THAN ONE SUCH “NOT OKAY” BOLT IN ANY ONE END CONNECTION, CHECK ALL BOLTS IN THAT END CONNECTION. A MINIMUM OF THREE BOLTS SHALLBE CHECKED IN EACH END CONNECTION. PHOTOS SHALL BE TAKEN TO INDICATE THE BOLTS TESTED. ALL BOLT ASSEMBLIES AND DTI WASHERS SHALL BE VISUALLY INSPECTED. THE BOLT INSPECTOR SHALL PROVIDE COMPLETE PHOTO DOCUMENTATION OF ALL BOLTS AFTERTIGHTENING CLEARLY SHOWING THE CONDITION OF THE DTI WASHERS. AJAX/DTI BOLT SPECIFICATIONS AND TIGHTENING PROCEDURE M20 AJAX/DTI BOLT ASSEMBLY COMPONENT SPECIFICATIONS: SHEAR PLANE DETAIL 1: M20 AJAX/DTI BOLT ASSEMBLY GRIP SHEAR SLEEVE (29mm OD) AJAX SOLID WASHER HARDENED FLAT WASHER AJAX HH NUT (LUBRICATE THREADS, SEE NOTES) AJAX M20 BOLT NOMINAL 20mm OD MACHINED END OF BOLT FOR AJAX INSTALLATION TOOL M20 SQUIRTER®DTI SHOP DRILLED HOLE IN REINFORCING MEMBER NOMINAL 30mm (1-3/16" MAXIMUM) BEFORE GALVANIZING, HOT DIP GALVANIZED PER ASTM A123 REINFORCING MEMBER (EXTERIOR OF POLE) MONOPOLE SHAFT FIELD DRILLED HOLE IN SHAFT WALL, NOMINAL 30mm (1-3/16" MAXIMUM) COAT WITH ZRC ZINC COLD-GALVANIZE COMPOUND. AJAX M20 BOLT HEAD: 29mm OD AJAX SPLIT WASHER ELEV. 0" ELEV. 42'0" ELEV. 84'8 38 " ELEV. 113'1 316 " ELEV. 162' 0" SCALE 1 : 120 A S-5 00 THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF CROWN CASTLE. IT IS PRODUCED SOLELY FOR USE BY CROWN AND ITS AFFILILATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PREMISSION OF CROWN CASTLE. PREPARED FOR CROWN CASTLE BU D A B C D 345678 8 7 6 5 4 3 2 1 E F E F S-5 00 ELEVATION . NO.DATE DESCRIPTION BY REVISIONS ENG/QA BY: DFT BY: DFT/QA BY: APRV'D BY: SCALE: N.T.S. DATE: DATE: DATE: DATE: REV SITE NAME: BU NUMBER: WO NUMBER: SITE ADDRESS: ATWOOD DRIVE SC 9/19/2014 MA NORTHAMPTON II CAC800530 929528 HAMPSHIRE COUNTY NORTHAMPTON, MA 01060 9/19/14 INITIAL RELEASE MB MB SC 9/19/2014 9/19/2014 9/19/2014 POLESPECIFICATIONS POLESHAPETYPE: TAPER: SHAFTSTEEL: BASEPLSTEEL: ANCHORRODS: 18SIDEDPOLYGON 0.26002IN/FT A572Ͳ65 60KSIYIELDSTRENGTH 2.25INCHA615GR75 A MODIFICATIONELEVATION(FT) POLEMODIFICATIONSCHEDULE REFERENCESHEET SͲ5ShaftReinforcement114Ͳ129 SHAFT SECTION 1 13.000 25.710 2 24.360 32.600 3 30.802 42.940 4 40.667 53.000 SECTION LENGTH 48.88 0.1875 3.75 32.17 0.3125 4.58 47.25 0.3750 47.96 0.3750 5.93 0.00 SHAFTSECTIONDATA PLATE THICKNE LAP SPLICE DIAMETERACROSS FLATS(IN) 66 688.5 129 TOPELEVATION (FT)PARTNUMBER FLAT/DEGREE() 2,8,14CCIͲAFPͲ04510015 CCI FLATPLATE(65KSI)REINFORCINGSCHEDULE BOTTOM ELEVATION(FT) 114 TOTALSTEEL WEIGHT (BLACK) 688.566 STEELWEIGHT PERPLATE (BLACK) TOTALAJAX BOLT QUANTITY 229.5 MAXINTERMEDIATE BOLTSPACING 1'Ͳ8"8 AJAXBOLT QUANTITYPER PLATE 22 TERMINATION BOLTS (BOTTOM) TERMINATION BOLTS (TOP) 8 1 2 3 4 5 6 7 NOTESFORCROWNREINFORCING(65KSI)MATERIAL: DONOTWELDWITHOUTAPPROVALFROMTHEEOR. SHIMSFORMONOPOLEREINFORCEMENTMEMBERSHALLBEREQUIREDWHEREGAPSBETWEENTHEPOLESHAFTANDREINFORCINGMEMBEREXISTATFASTENERLOCATIONS.FOR INTERMEDIATECONNECTIONS,THEMINIMUMSHIMLENGTHANDWIDTHSHALLBETHEWIDTHOFTHEREINFORCINGMEMBER.FORTERMINATIONCONNECTIONS,ACONTINUOUS SHIMPLATE(PREFERRED)OREQUIVALENTINDIVIDUALSHIMPLATESTHEWIDTHOFTHEREINFORCINGMEMBERMAYBEUSED.SHIMTHICKNESSSHALLBENOLESSTHAN1/16”. STACKINGOFSHIMSISPERMITTED. ALLFLATPLATEREINFORCEMENTISTOBEINSTALLEDCENTEREDONITSDESIGNATEDFLAT,UNO. SEECMRP65KSIPARTSCATALOG2ndEDITIONFORPARTDETAILS. ASANALTERNATIVETOUSINGDTIWASHERS,AJAXBOLTSMAYBEPRETENSIONEDPERTHEAISCTURNͲOFͲNUTMETHOD. ONMULTISIDEDPOLES,EXISTINGSAFETYCLIMBISCONSIDEREDFLAT1THENFLATSARENUMBEREDCOUNTERCLOCKWISE. CLIMBINGPEGSTOBERELOCATEDASREQUIRED.