CSO Permit Set 12-3-1527'-0"18'-10"13'-3"3'-0"21'-9"11'-8"9'-2"6'-8"EXISTING
WATER
FOUNTAIN
N
PLAN NORTH
STORAGE SHELVING
BY OTHERS
HALLWAY
ENTRY
10'-312"5'-0"ENTRY
PHD OFFICE 3
95 SF
11'-4"
1 1/4" = 1'-0"
PROPOSED PLAN - FIRST FLOOR BUILD-OUT
PHD OFFICE 1
125 SF
PHD OFFICE 2
115 SF
10'-8"9'-4"7'-1"11'-7"13'-0"PHD OFFICE 4
115 SF
10'-0"25'-3"10'-0"STORAGE
60 SF
5'-0"
BREAK
ROOM
6'-2"5'-71
2"7'-10"NO DOOR
FRAMED
OPENING
12'-10"12'-9"
FSS
SUPERVISOR 1
125 SF
FSS
SUPERVISOR 2
125 SF
HALLWAY
PHD OFFICE 5
140 SF
11'-5"
FULL HEIGHT WALL
16'-0"17'-512"
BA LEVEL FSW'S - 16 COUNT
OPEN WORKSPACE
CLINICIAN'S W/ PC'S
10 COUNT 11'-412"1'-8"
COPIER / PRINTER
AREA
4'-0"5'-9"
7'-8"
PROVIDE DOUBLE
STUDS AT THIS WALL
TO FRAME AROUND
EXISTING COLUMNS
OPEN OFFICE
NO WORK - OUTSIDE OF
CONTRACT WORK AREA
NO WORK - OUTSIDE OF
CONTRACT WORK AREA
10'-0"('= Fire Extinguisher
'5
':+6
= Emergency Light
and Strobe
= Egress Lighting
= Exit Sign
(Lighted)
(#2
5
= Fire Alarm Pull
= Smoke Detector
'.
MECHANICAL
AND ELECTRICAL
CONTRACTORS
COORDINATE
AND PROVIDE
VENTING FAN.
MECHANICAL AND ELECTRICAL
CONTRACTORS COORDINATE
AND PROVIDE VENTING FAN.
'5
'5
':+6
':+6
':+655
55
5'.'.'.RECESSED FIRE
EXTINGUISHER
RECESSED FIRE
EXTINGUISHER
11'-412"PROVICE DRYWALL WINDOW SURROUND
TO MATCH CSO 2ND FLOOR OFFICE
LAYOUT, TYPICAL.
NO WORK - OUTSIDE OF
CONTRACT WORK AREA
NO WORK - OUTSIDE OF
CONTRACT WORK AREA('
(#2
(#2
Typical Offices
Open Office 101
Toilet 110 & 115
Break Room 114
ROOM NAME FLOOR
26 oz. solid dyed nylon level loop carpet
26 oz. solid dyed nylon level loop carpet
VCT Mannington
BASE
carpet
carpet
vinyl cove base
vinyl cove baseVCT Mannington
WALLS
paint
paint
paint
paint
CEILING
2' x 4' USG 2742 Illusion Reveal
2' x 4' USG 2742 Illusion Reveal
2' x 4' USG 2742 Illusion Reveal
2' x 4' USG 2742 Illusion Reveal
FINISH SCHEDULE - See A1.2 for complete finish schedule
NOTE:
All room finishes to match current CSO
floor, wall and ceiling finishes at
current 2nd floor office space.
A1.3
2
KEY FOBS BY
OTHERS
KEY FOBS BY
OTHERS
106
105104
107
108
109
110
115
103102
101
112
113
RECESSED FIRE
EXTINGUISHER
('
'.
ALIGN EMERGENCY
LIGHTING ABOVE
FIRE EXTINGUISHER 7'-10"('
POWER POLE
8'-3"8'-412"FURR OUT WALL WITH
6" METAL STUD FOR
ELECTRIC PANEL
INSET.
ELECTRIC PANEL
LOCATION
1'-2"2'-2"SIDELIGHT AT
ENTRY DOOR TO
MATCH STANDARD
ENTRY DOORS
EXISTING MAILBOXES
'5SHELVING N.I.C.
1'-7"5'-2"5
8"5
8"35
8"
47
8"2"58"TYPICAL JAMB
ANCHOR
115
16"1 9
16"
5 3/4" FRAME
DEPTH
7/16" RETURN
5/8" THICK PAINTED
GYPSUM BOARD
TYPICAL 1 3/4" THICK SOLID
CORE WOOD DOOR LEAF WITH
BIRCH VENEER FINISH
TYPICAL PAINTED HOLLOW
METAL DOOR FRAME
7/16" RETURN
CONTINUOUS 3 1/2" THICK
FIBERGLASS SOUND
ATTENUATION BATT INSULATION
5/8" THICK PAINTED
GYPSUM BOARD
TYPICAL 3 5/8" DEEP X 20
GAUGE GALVANIZED STEEL
FRAMING CHANNELS AT 1'-4"
ON CENTER
PROVIDE NEW CARPET
BASE TO MATCH FINISH AT
EXISTING CSO OFFICES AT
ALL NEW WALLS.
7/16" RETURN
7/16" RETURN
2"58"TYPICAL PAINTED HOLLOW
METAL DOOR FRAME
CONTINUOUS 3 1/2" THICK
FIBERGLASS SOUND
ATTENUATION BATT INSULATION
5 3/4" FRAME
DEPTH
1 9
16"115
16"
TYPICAL 1 3/4" THICK SOLID
CORE WOOD DOOR LEAF WITH
BIRCH VENEER FINISH
5/8" THICK PAINTED
GYPSUM BOARD
47
8"
35
8"5
8"5
8"
TYPICAL 3 5/8" DEEP X 20
GAUGE GALVANIZED STEEL
FRAMING CHANNELS AT 1'-4"
ON CENTER
5/8" THICK PAINTED
GYPSUM BOARD
TYPICAL DOUBLE HEADER
CONDITION AT DOOR HEAD
DETAIL
2 3" = 1'-0"
TYPICAL DOOR HEAD DETAIL
3 3" = 1'-0"
TYPICAL DOOR JAMB DETAIL
WALL NOTES:
1.ALL INTERIOR WALLS SHALL HAVE 20 GA. METAL STUDS AT 16"
ON CENTER WITH 5/8" TYPE "X" GYPSUM WALL BOARD BOTH
SIDES AND BATT INSULATION. 10' WALLS AND 9'-6" CEIILING.
(VERIFY WALL AND CEILING HEIGHTS IN FIELD - VERIFY
CLEARANCE FOR MECHANICAL DUCTWORK AND WINDOW HEAD
CLEARANCE.
2.WALLS AT HALLWAYS SHALL HAVE METAL STUDS AND DRYWALL
EXTEND TO METAL DECK ABOVE. PROVIDE FIRE CAULKING.
3.ALL EXTERIOR WALLS SHALL HAVE 5/8"TYPE "X" DRYWALL OVER
EXISTING METAL STUDS (VERIFY IN FIELD). PROVIDE DRYWALL
TO METAL DECK ABOVE. PROVIDE FIRE CAULKING. NO BATT
INSULATION OR VAPOR BARRIER IS REQUIRED AT EXTERIOR
WALLS AS THE BUILDING ENVELOPE MEETS ENERGY
REQUIREMENTS.
FLOOR NOTES:
1.CUT BACK EXISTING DRAIN PIPES AT EXISTING SLAB TO REMAIN.
PATCH AND REPAIR AT REMOVED DRAIN PIPE CONNECTIONS.
2.CUT IN AND PROVIDE NEW DRAIN PIPING FOR TWO PROPOSED
SINGLE USER RESTROOMS AND AT THE BREAK ROOM.
PLUMBING CONTRACTOR TO CONSULT EXISTING AS BUILT
PLUMBING DRAWINGS FOR CONNECTIONS TO WATER , VENT
AND DRAIN LINES.
GENERAL NOTES:
1.GENERAL CONTRACTOR TO COORDINATE WITH DESIGN BUILD
FIRE PROTECTION COMPANY FOR FIRE SPRINKLERS AT NEW
OFFICE BUILD OUT. FIELD VERIFY EXISTING SPRINKLER LINES
TO BUILD OFF OF.
2.GENERAL CONTRACTOR TO COORDINATE WITH DESIGN BUILD
MECHANICAL CONTRACTOR TO PROVIDE HEATING, AIR
CONDITIONING AND VENTING AT NEW OFFICE BUILD OUT. FIELD
VERIFY EXISTING MECHANICAL DUCTWORK TO CONNECT TO.
PROVIDE FRESH AIR SUPPLY AND RETURN AT ALL OFFICES.
3.VERIFY LOCATION OF ANY EXISTING SERVICE SINK(S) AT FIRST
FLOOR OF BUILDING PRIOR TO OFFICE BUILD OUT. ONE
SERVICE SINK PER FLOOR IS REQUIRED. CONSULT WITH
OWNER IF ADDITIONAL SERVICE SINK IS DESIRED.
4.GENERAL CONTRACTOR TO COORDINATE WITH ELECTRICAL
CONTRACTOR, ARCHITECT AND OWNER ON OUTLET LOCATION
FOR OPEN OFFICE SPACE.
5.GENERAL CONTRACTOR AND ELECTRICAL CONTRACTOR TO
COORDINATE FIRE ALARM SYSTEM CONNECTIONS TO EXISTING
FIRE ALARM SYSTEM WITHIN BUILDING. GENERAL CONTRACTOR
TO HIRE SUBCONTRACTOR FOR FIRE ALARM SYSTEM AS
NEEDED.
6.PROJECT BUILD OUT AREA IS 2,688 SF.
Scale:
Date:
Drawn By:
Project:
Consultants:
GD
AS NOTED Clinical and Support Options, Inc.
Northampton / 1-91 Professional Center
1st Floor Tenant Improvements
8 Atwood Drive
Northampton, MA
Index of Plans
A1.1 First Floor Plan
A1.2 Data and Outlet Plan / Finish Schedule
A1.3 Reflected Ceiling Plan
CLINICAL AND SUPPORT OPTIONS, INC.NORTHAMPTON / 1-91 PROFESSIONAL CENTER8 ATWOOD DRIVENORTHAMPTON, MAevelopmentssociatesDA6 3 0 S I L V E R ST R E E T A G A W A M , M ACONSTRUCTION
PLANS
1512
11.30.2015
Revisions:
REV 1: 11/20/2015
REV 2: 12/3/2015
27'-0"18'-10"13'-3"3'-0"21'-9"11'-8"9'-2"6'-8"EXISTING
WATER
FOUNTAIN
N
PLAN NORTH
HALLWAY
ENTRY
ENTRY
PHD OFFICE 3
1 1/4" = 1'-0"
PROPOSED PLAN - OUTLET PLAN - FIRST FLOOR BUILD-OUT
PHD OFFICE 1 PHD OFFICE 2
PHD OFFICE 4
25'-3"10'-0"STORAGEBREAK
ROOM
FSS
SUPERVISOR 1
FSS
SUPERVISOR 2
HALLWAY
PHD OFFICE 5
FULL HEIGHT WALL
BA LEVEL FSW'S - 16 COUNT
COPIER / PRINTER
AREA
OPEN OFFICE
NO WORK - OUTSIDE OF
CONTRACT WORK AREA
NO WORK - OUTSIDE OF
CONTRACT WORK AREA
NO WORK - OUTSIDE OF
CONTRACT WORK AREA
NO WORK - OUTSIDE OF
CONTRACT WORK AREA
GFI
POWER POLE
DESK, N.I.C.,
TYPICAL
N.I.C.
DESK, N.I.C.,
TYPICAL
DESK, N.I.C.,
TYPICAL
DESK, N.I.C.,
TYPICAL
DESK, N.I.C.,
TYPICAL
DESK, N.I.C.,
TYPICAL
DESK, N.I.C.,
TYPICAL
DUPLEX RECEPTACLE
DUPLEX RECEPTACLE GROUND FAULTGFI
TEL / DATA BY TENANT
ELECTRICAL CONTRACTOR TO COORDINATE
ELECTRICAL PANEL LOCATION IN FIELD WITH
GENERAL CONTRACTOR.
OPEN WORKSPACE
CLINICIAN'S W/ PC'S
10 COUNT
FURR OUT
WALL WITH 6"
METAL STUD
FOR ELECTRIC
PANEL INSET.
ELECTRIC PANEL
LOCATION
101
ROOM #ROOM NAME
Open Office
102
103
104
105
106
107
108
109
110
111
112
113
114
115
2
FINISH SCHEDULE
FSS Supervisor 1
FSS Supervisor 2
PHD Office 1
PHD Office 2
PHD Office 3
PHD Office 4
PHD Office 5
Storage
Toilet #2
Hallway
Hallway
Entry
Break Room
Toilet #1
FLOOR
Carpet
FLOOR FINISH
26 oz. Broadloom Carpet and Base - Philadelphia PC - Touchdown
Carpet 26 oz. Broadloom Carpet and Base - Philadelphia PC - Touchdown
Carpet 26 oz. Broadloom Carpet and Base - Philadelphia PC - Touchdown
Carpet 26 oz. Broadloom Carpet and Base - Philadelphia PC - Touchdown
Carpet 26 oz. Broadloom Carpet and Base - Philadelphia PC - Touchdown
Carpet 26 oz. Broadloom Carpet and Base - Philadelphia PC - Touchdown
Carpet 26 oz. Broadloom Carpet and Base - Philadelphia PC - Touchdown
Carpet 26 oz. Broadloom Carpet and Base - Philadelphia PC - Touchdown
Carpet 26 oz. Broadloom Carpet and Base - Philadelphia PC - Touchdown
Carpet 26 oz. Broadloom Carpet and Base - Philadelphia PC - Touchdown
Carpet 26 oz. Broadloom Carpet and Base - Philadelphia PC - Touchdown
VCT Mannington #135 - Seaspray
Mannington #135 - SeasprayVCT
VCT Mannington #135 - Seaspray
VCT Mannington #135 - Seaspray
BASE
Carpet
Carpet
Carpet
Carpet
Carpet
Carpet
Carpet
Carpet
Carpet
Carpet
Carpet
Vinyl Cove
Vinyl Cove
Vinyl Cove
Vinyl Cove
WALL PAINT TRIM PAINTBASE COLOR
John. #123 Mineral Spring
John. #123 Mineral Spring
John. #123 Mineral Spring
John. #123 Mineral Spring
CEILING
Armstrong 2' x 4' Illusion Reveal
Armstrong 2' x 4' Illusion Reveal
Armstrong 2' x 4' Illusion Reveal
Armstrong 2' x 4' Illusion Reveal
Armstrong 2' x 4' Illusion Reveal
Armstrong 2' x 4' Illusion Reveal
Armstrong 2' x 4' Illusion Reveal
Armstrong 2' x 4' Illusion Reveal
Armstrong 2' x 4' Illusion Reveal
Armstrong 2' x 4' Illusion Reveal
Armstrong 2' x 4' Illusion Reveal
Armstrong 2' x 4' Illusion Reveal
Armstrong 2' x 4' Illusion Reveal
Armstrong 2' x 4' Illusion Reveal
Armstrong 2' x 4' Illusion Reveal
REMARKS
Door Stain: Lampson Prefinished Plain Sliced
Maple-10 color PLS-103 (Stratford Mahogany)
Door Hardware: Corbin Russwin 3800 Series,
brushed nickel
Fire Extinguisher Cabinets: Semi-recessed.
Cabinets: JSI- Sturbridge or equal / Sturbridge /
tubular hardware
Countertops: Wilsonart HD #1819k-35 Bella
Venito (rounded edge)
ADDITIONAL FINISH NOTES
Scale:
Date:
Drawn By:
Project:
Consultants:
GD
AS NOTED CLINICAL AND SUPPORT OPTIONS, INC.NORTHAMPTON / 1-91 PROFESSIONAL CENTER8 ATWOOD DRIVENORTHAMPTON, MAevelopmentssociatesDA6 3 0 S I L V E R ST R E E T A G A W A M , M ACONSTRUCTION
PLANS
1512
11.30.2015
Revisions:
REV 1: 11/20/2015
REV 2: 12/3/2015
27'-0"18'-10"13'-3"3'-0"21'-9"11'-8"9'-2"6'-8"N
PLAN NORTH
HALLWAY
ENTRY
ENTRY
PHD OFFICE 3
1 1/4" = 1'-0"
PROPOSED 1st FLOOR REFLECTED CEILING PLAN - FIRST FLOOR BUILD-OUT
PHD OFFICE 1 PHD OFFICE 2
PHD OFFICE 4
25'-3"10'-0"STORAGE
BREAK
ROOM
FSS
SUPERVISOR 2
HALLWAY
PHD OFFICE 5
FULL HEIGHT WALL
16'-0"17'-512"
FSS
SUPERVISOR 1
DRYWALL SOFFIT
2' X 4' FLUORESCENT
LIGHT FIXTURE
NOTE: DISCUSS OPTION FOR LED
RECESSED LIGHT FIXTURE
OPTIONS WITH OWNER.9'-6"
9'-6"
9'-6"
9'-6"
9'-6"
9'-6"
9'-6"
9'-6"
9'-6"
9'-6"
DRYWALL SOFFIT
9'-6"
POWER POLE
TEMPERED
SAFETY GLASS
AT SIDELIGHT,
TYPICAL
7'-0"1'-6"3'-0"
5'-0"7'-2"2"2"2"7'-0"3'-0"
3'-4"7'-2"2"2"
3 3/4" = 1'-0"
DOOR FRAME W/ SIDELIGHT
4 3/4" = 1'-0"
DOOR FRAME W/O SIDELIGHT
SEE FLOOR PLAN FOR LOCATION
OF DOORS WITH SIDELIGHTS.
ALL DOOR TO BE SOLID CORE
BIRCH - PREFINISHED.
MATCH EXISTING CSO DOORS AT
2ND FLOOR.4"2 1/2" = 1'-0"
CASEWORK AT BREAK ROOM 114
2'-8"2'-6"2'-6"
ACCESSIBLE
COUNTERTOP -
34" HIGH
4" HIGH BACKSPLASH
2'-10"FUTURE
REFRIGERATOR
BY OTHERS
2" SCRIBE
PANELPROVIDE
FINISHED END
PANEL
CONSTRUCTION
PLANS
Scale:
Date:
Drawn By:
Project:
Consultants:
GD
AS NOTED CLINICAL AND SUPPORT OPTIONS, INC.NORTHAMPTON / 1-91 PROFESSIONAL CENTER8 ATWOOD DRIVENORTHAMPTON, MAevelopmentssociatesDA6 3 0 S I L V E R ST R E E T A G A W A M , M A1512
11.30.2015
Revisions:
REV 1: 11/20/2015
REV 2: 12/3/2015
Revisions:
REV 2: 12/3/2015
Millwork revisions at