Loading...
31A-033 (9) 15 FRANKLIN ST BP-2019-0574 GIs#: COMMONWEALTH OF MASSACHUSETTS Map-.Block:31A-033 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2019-0574 Project# JS-2019-000695 Est.Cost:$33048.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO. Const.Class: Contractor., License: Use Group: SUNBUG SOLAR 109144 Lot Size(sa.ft.): 9931.68 Owner: MUSPRATT MATT&ASHLEY Zoning:URB(100)/ Applicant: SUNBUG SOLAR AT. 15 FRANKLIN ST Applicant Address: Phone: Insurance: 411A HIGHLAND AVE (413)884-1000 WC SOMERVILLEMA02144 ISSUED ON.1111412018 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALL 27 PANELS ON ROOF - 9.72 KW - STRUCTURAL REINFORCEMENT OF ROOF TO BE DONE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 11/14/2018 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner DocuSign Envelope ID:B02D4593-1 BD9-4734-8484-BE000292B67C S�[ 2 - C 1/v I O cie apt,001':::7' hent use only City of Northampton .�% Building Department 212 Main Street S ►e3 + . ;'- Room 100 g ' Northampton, MA 01060 T UIP phone 413-587-1240 Fax 413-587-1272 e; APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION6�" ` - C 7 y F4 FZ 1.1 Property Address: This section to be completed by office 15 Franklin St NOV - g 2018 ap 31 A Lot 033 unit 001 one Overlay District DEPT.OF BUILDING INSPECTIONQIm S District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AG 2.1 Owner of Record: Muspratt, Ashley & Matthew 15 Franklin St Northampton, MA 01060 am Current Mailing Address: 617-775-5530 1, ATelephone Signature ' 2.2 Authorized Aoent: Aaron Simms - SunBug Solar 66 Westfield Ind Park Rd Westfield, MA 01085 am W. Current Mailing Address: aneW (Milks 518-530-0803 ign Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 27,537 (a) Building Permit Fee 2. Electrical 5,511 (b) Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total= 0 +2+3+4.+5) 33,048 Check Number This Section For Official Use Only BuildingPermit Number: Date Issued: Signature: f l 3 Building Commissioner/Inspector of Buildings Date et a r oh @ Sr44 Co 0,\ EMAIL ADDRESS (REQUIRED; EITHER HOMEOWNER OR CONTRACTOR) DocuSign Envelope ID:B02D4593-1BD9-4734-8484-BE000292B67C Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department .. r..._.. .e, ..a. ......... Lot Size Frontage Setbacks Front Side L. R — L•, .... R: Rear n.,... ., Building Height ._,.� Bldg.Square Footage � 'i ! a Open Space Footage o _ (Lot area minus bldg&paved parking) #of Parking Spaces - - - - Fill: (volume&Location) _ _.___ ,. .._........ .. _ A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO 0 DON'T KNOW @ YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DON'T KNOW Q YES 0 IF YES: enter Book Pages and/or Document#' _ .a_..._. ._. B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW 0 YES Q IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES 0 NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES 0 NO 0 IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading, excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES ® NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. DocuSign Envelope ID:B02D4593-iBD9-4734-8484-BE000292B67C SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House Addition ❑ Replacement Windows Alteration(s) ❑ Roofing Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [0 Siding [0] Other[oIJ Brief Description of Proposed Solar installation:27 p els to be installed on roof as er attact�d documents. 9.72 kW. Work: Cour Y�GP.�ts14 0� LOOP' 6�t do�� APiYlt4i`f►'uc.�Ydv�s a�&)g0fijsy+��a Alteration of existing bedroom Yes No Adding new bedroom Yes No /� r Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a,if Newhouse and or addition to existina housing, complete the followina: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1 Ashley & Matthew Muspratt as Owner of the subject property hereby authorize SunBug Solar fteh-If, in II matters rel his building permit application. AjUe,, mvspr"44dF- 9/17/2018 6:33:28 AM PDT Signa u o w r" Date Aaron Simms as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Aaron Simms rintiVarrilonedbyo ArilwA SIMMS 9/12/2018 9:20:50 AM PDT ign gent Date DocuSign Envelope ID:B02D4593-1 BD9-4734-8484-BE000292B67C SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: Aaron Simms CS-109144 License Number 66 Westfield Ind Park Rd Westfield, MA 01085 7/21/2019 E3 fined by: Expiration Date AMA, ift%S 518-530-0803 ign Telephone 9.Reatatere'Home Improvement Contractor: Not Applicable ❑ SunBug Solar 163091 Company Name Registration Number 411A Highland Ave, Suite 312 Somerville, MA 02144 5/10/2019 Address Expiration Date Telephone 617-500-3936 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ® No...... ❑ DocuSign Envelope ID:B02D4593-1 BD9-4734-8484-BE000292B67C City of Northampton 4 '' ; Massachusetts ��?' 3►. `"'<< f.i •.G DEPARTMENT OF BUILDING INSPECTIONS S` jti .Y 212 Main Street •Municipal Building Jd,.... .oC� Northampton, MA 01060 s67y �� Debris Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. The debris from construction work being performed at: 15 Franklin St (Please print house number and street name) Is to be disposed of at: 66 Westfield Ind Park Rd Westfield, MA 01085 (Please print name and location of facility) Or will be disposed of in a dumpster onsite rented or leased from: (Company Name and Address) DocuSpned by: 9/12/2018 9:20:50 AM PDT Signa ure o ermit Applicant or Owner Date If, for any reason, the debris will not be disposed of as indicated, the Applicant or Owner shall notify the Building Department as to the location where the debris will be disposed. DocuSign Envelope ID:1302D4593-1BD9-4734-8484-BE000292B67C \ The Commonwealth of Massachusetts UVDepartment of IndustrialAccidents 1 Congress Street, Suite 100 Boston,MA 02114-2017 www mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/Individual):SunBug Solar Address:411A Highland Ave, Suite 312 City/State/Zip:Somerville, MA 02144 Phone#:617-500-3936 Are you an employer?Check the appropriate box: Type of project(required): 1.[E]I am a employer with 10 employees(full and/or part-time).* 7. 0 New construction 2.M I am a sole proprietor or partnership and have no employees working for me in 8. E]Remodeling any capacity.[No workers'comp.insurance required.] 9. El Demolition 3.[—]l am a homeowner doing all work myself[No workers'comp.insurance required.]t 10E]Building addition 4.❑I am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole 11.❑Electrical repairs or additions proprietors with no employees. 12.❑Plumbing repairs or additions 5.❑I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13QRoof repairs These sub-contractors have employees and have workers'comp.insurance? Solar Installation 6.❑We are a corporation and its officers have exercised their right of exemption per MGL c. 14.Q✓ Other 152,§1(4),and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#I must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. New York Marine and General Insurance Insurance Company Name: Policy#or Self-ins.Lic.#:WC201700015422 Expiration Date:4/30/2019 Job Site Address:15 Franklin St City/State/Zip:Northampton, MA 0106C Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereb AWW MdW the pains and penalties of perjury that the information provided above is true and correct. Si afore: Date: 9/12/2018 9:20:50 AM PDT Phone#:518- - Official use only. Do not write in this area, to be completed by city or town official! City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: Massachusetts Department of Public Safety Board of Building Regulations and Standards License: CS-109144 Construction Supervisor AARON SIMMS ; . ►► 61 MOUNT VERNON ST APT 3 ARLINGTON MA 02476 r-,jZZK &,—� Expiration: Commissioner 07/21/2019 Office of Consumer Affairs and Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement�ontractor Registration Type: LLC Registration: 163091 SUN BUG SOLAR L.L.C. Expiration: 05/10/2019 411A HIGHLAND AVE. ST 312 SOMERVILLE, MA 02144 _ - - Update Address and return card. Mark reason for change. SCA 1 as 20M-05/11 r•1 r-I Cw�..ln!mjent r1 1 met Cjrfi _�- Office of Consumer Affairs&Business Regulation H�= , HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only - TYPE: LLC before the expiration date. If found return to: R291stration Expiration Office of Consumer Affairs and Business Regulation 163091 05/10/2019 10 Park Plaza-Suite 5170 SUN BUG SOLAR LLC Boston, MA 02 16 CHENEY BRAND 411A HIGHLAND AVE. ST 312 _ SOMERVILLE, MA 02144 Undersecretary alid without signature DATE(MM/DO/YYYY) ACCORo® CERTIFICATE OF LIABILITY INSURANCE 4/30/2018 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer ri hts to the certificate holder in lieu of such Endorsement(s). PRODUCER C 'TACT Arthur J. Gallagher Risk Management Services, Inc. NAME: PHONE 617-261-6700 FAX 617-646-0400 470 Atlantic Avenue Boston MA 02210 E-MAILAnnPFQQ- INSURER(S)AFFORDING COVERAGE NAIC 8 INSURER A:ProSi ht Specialty Insurance INSURED SUNBSOL-01 INSURER B:Safe Indemnity Insurance Company 33618 SunBug LLC INSURER C:New York Marine And General Insurance 16608 SunBug Solar, LLC SunBug M, LLC INSURER D: Somerville MA 02144 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:547920256 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE POLICY EFF POLICY EXP LIMITS LTR INSD WVD POLICY NUMBER MM/DD/YYYY MM/DD/YYYY A X COMMERCIAL GENERAL LIABILITY PK201800010568 4/30/2018 4/30/2019 EACH OCCURRENCE $1,000,000 DAMAGE TO RENTE15-- CLAIMS-MADE FX OCCUR PREMISES Ea occu encs $300,000 MED EXP(Any one person) $5,000 PERSONAL&ADV INJURY $1,000,000 GENT AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 X POLICY a JECT �LOC PRODUCTS-COMP/OP AGG $2,000,000 E OTHER: $ B AUTOMOBILE LIABILITY 6245191 4/30/2018 4/30/2019 COMBINED STRUCIETOW7— Ea accident $1,000,000 ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED A A X AUTOS ONLY X AUTOS ONLY cpr accident $ A X UMBRELLA LIAB X OCCUR UM201800005479 4/30/2018 4/30/2019 EACH OCCURRENCE $5,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $5,000,000 DED X RETENTION$10,000 $ C WORKERS COMPENSATION WC201800015422 4/30/2018 4/30/2019X PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE ❑ N/A E.L.EACH ACCIDENT $1,000,000 OFFICER/MEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $1,000,000 A Errors&Omissions PK201800010568 4/30/2018 4/30/2019 $1,000,000 Each Occ. $1,000,000 Aggregate DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) For Informational Purposes Only. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Evidence of Insurance THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE v ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD —'I 27' DRIVE – –– Uj rl W � r � r r r Co 74• 1 J Y I r r LL- i 71 r I r r r I 26' _ N E S LEGEND Scale:1"=20'-0' PROPERTY LINES o za a0' SETBACKS corsiDERnni OWNER: VII CE"&DI bTIN:—q� j 7(_ JOB REFERENCE 1902-Resi-W Muspratt,Ashley and Matt SYSTEM SIZE: 9.72 kW DC )EsrnlKa,: DATE REY dND uaeE TRE INFO RMA TION HEREIN CCM ONESMALLROT SBE UNMO FORTH UC,NOR OFI SO IT BE ISCEPf DRQNA 92N.V18 A TO RwRLLCNO SIMM eL R[1C, MOUNTING SYSTEM: SnapNRack RackinglSunModo Flashing 15 Franklin St MONITORING: SolarEdge Revenue Grade Monitoring aro oTRERs grace a s>rRauc SOl"R uc.v"mWCONSENTCRINCONNECTIONWTHTHE MODULES: LG 360Ne0NRNorthampton,MA 01060 UTILITY: NGrid 411AA».S, M2SAE ANDUSEUTHERESPECTIVESMBUOS0."R .A1,103I4/LLC SYSTEM Try1n RI81n/1?]052INVERTER: SolarEdge SE760OH-US RGM SHEET TITLE: PROPERTY PLAN SHEET NUMBER:1wxuww„ TILITY METER LOCATED ON NORTH SIDE OF RESIDENCE AND IS ACCESSIBLE 24/7/365 TILITY AC DISCONNECT LOCATED ON NORTH SIDE OF RESIDENCE WITHIN 1 OFT OF UTILITY METER AND ACCESSIBLE 24/7/365 RODUCTION METER AND SOLAREDGE SE7600H-US RGM INVERTER LOCATED IN BASEMENT 72KW DC ARRAY 27 LG 360 NEON R MODULES 27 SOLAREDGE P370 OPTIMIZERS -- _ SNAPNRACK SERIES 100 RACKING SYSTEM ' DRIVE W ' Uj I 1 1 I � � I vJ I Z I N E 1 S I I LEGEND I O UTILITY METER&WARNING LABEL I I . INVERTER&WARNING LABELS 01' 32' DC DISCONNECT&WARNING LABELS Ain _ I a AC DISCONNECT&WARNING LABELS C0NF10ENiIAL JOB REFERENCE: 1902-Resi-W OWNER:Mus raft,Ashley and Matt SYSTEM SIZE: 9.72 kW DC R V I N uDRAFTING INGBY THE INFORMATION r�EINC«rtar+EDswLNOT P eY DESCRIPnar DATE REv. BE USED WNW FOR soWRUC NOR SMUT BEoisrx� MOUNTING SYSTEM SnapNRack Racking/SunModo Flashing 15 Frankin St MONITORING: SolarEdge Revenue Grade Monitoring ORIGINAL szvm e A To OTHERS OUTSIDE OF a»alG soon I.I.C. tJlldlf� NITHDIff CONSEW OR IN CONNECTION WITH THE MODULES: LG 360 NEON Northampton,MA 01060 UTILITY: NGrid SIkmAlapH.b M..sL.en2 EAND USEOF THE REWECTNE SUNBIIG SOUR .-ft.1 Amm LLC SYSTEM T.(617))9=1(81n412a INVERTER: SolarEdge SE760OH-US RGM SHEET TITLE:SITE PLAN SHEET NUMBER:2 " LEGEND CONSTRUCTION PLAN E RAIL RAFTERS TILITY METER S cOLONNECT 0 ATTACHMENT POINTS ( TILT-UP MODULES ON NORTM Roc" BEST PRACTICES CONSULT PROJECT MANAGER -IAAX.RAIL O/ERHANO 16" -MAX.RAL SPAN W 4WTIDN SALE 79'(MNR 15.7"(MAX)FROM EDGE OF MCAUIES IN PORTRAIT -POSITION RAILS4 T(MAX.)FROM EDGE OF MODULES IN LANDSCAPE 66116" ROOF FRAMING MNRAFTERS'2(3'NOL — RAFTERS:hITRL—oC MP3 WA 5" MPI WA IM-1 PS WA MP6 WA 10 P2 ARRAY POSITION POSITION MN ROOF ARRAY CENTEREDON ROOF 133 " POSITION MPL ROOF ARRAY CENTER®ON ROOF 66116" ADDITIONAL WORK CRITTER GUARDS I WA 5' INVISBIEENOCLAMPS WA O' 242Y" SERVICE UPGRADE NA 3„ 3" STRUCTUROLREINFCRCEMET STRUCTURAL RENFORCEMENT REQUIRED SEE RETWORCEMENT VA W. J STAGGER PATTERN WA SPECIAL PERMrMNG WA EQUIPMENT LOCATION INVERTER MOULT INVERTER IN EASEMENT PRODUCTONMETER RGMINVERTERNOADOTRXIAL METERREQUIRED 201116' AC DISCONNECT NSTALLVATWNIOFTOFUTLITYMETER MUSTEEACCESSELE2Nr.� V EINCRCEMFNT REQUIRED 615 , FO2MP+oNLY PROJECT NOTES 16' (SEE REINFORCEMENT PUN( 2" SNR MIDCRAMPS,END CLAMPS,RAL SPLICES TCROUE TO 10FT-UEIS 4 " 1 011 P1 5" T�KFORIMAATIRXN HEREIN CONTAINED 9LALL NOT 108 REFERENCE: 1902-Resi-W OWNER: Muspratt,Ashley and Matt SYSTEM SIZE: 9.72 kW DC DESCRPDON. V NDATE I REV— BE EN aNa8,G F� N�ORrS�W1�T BEDISSCL MOUNTING SYSTEM SnapNRack RackinglSunModo Flashing 15 Franklin St MONITORING: SolarEdge Revenue Grade Monitoring DRIGINAL geno+e A Ry CitAtJ TOOIHERS Wi80E OF SUNBUG SOLAR U.C. MMTNGUTCONSENTORINCONNECTION WTHTHE MODULES: LG 360NEONR Northampton,MA01OW UTILITY: NGrid <NIARI,—A,As 312 SALE AND USE OF THE RESPECTIVE S.RNEUG SOLAR Sa,wvi.MA W. LLC SYSTEM T:(17)�3533 F(07)02-3033 INVERTER: SolarEdge SE76WH-US RGM SHEET TITLE.CONSTRUCTION PLAN SHEET NUMBER:3w —.".Mc,a — o� SE760OH-US STRING REQUIREMENTS MINIMUM LENGTH: 8 OPTIMIZERS MAXIMUM POWER:6000 WATTS C RUN FROM MAIN + HOUSE TO OUTBUILDING CCWDEIMA- OWNER: R VI I N DESMILMNFTIMBT: THESED FOR T HE HEAEW CONTMNEO SHALL NOT JOB REFERENCE 1902-Resi-W Muspraq Ashley and Matt SYSTEM SIZE: 9.72 kW DC GExRirnoN DATE REV: DOWA(ABBE BE USEDSORRLLC,NOR OFLLITBE EXCEPT ORIGINAL 9'7BR078 A SUNBUD SOLAR LLC,NOR SIALL IT BEdSCLosEd MOUNTING SYSTEM SnapNRack RackinglSunModo Flashing 16 Franklin St MONITORING: SolarEdge Revenue Grade Monitoring rJ E)9tBUq , TOOTHERS CUTSIDEOF SLMBUS SOLAR LLC, Kv NATHOUT CONSBAT OR 1NCOWLICT WIM THE MODULES: LG 360 Ne0NR Northampton,MA 01060 UTILITY: NGrid A,u HyAWtl Ave.Sb 3,] SALE MIDUSEOFTHERESPECRVESLNBUGsOL R Smoak AN P11M LLC SYSTBA T:(SIT) =F.(611/12W INVERTER: SolarEdge SE760OH-US RGM SHEET TITLE: STRING DIAGRAM SHEET NUMBER 4 MOUNTING PLAN MPI i SNR RAIL LASHING SNR END CLAMP V MODULE TYP. rSNR MID CLAMP RAFTER TL-FOOT MOUNTING METHOD n 4 r 2 SNR END CLAMP 6.00„ 1 PVM DOLE SNAPNRACK RAIL L-F T 16" I 4811 AIL POSITION `MAX. RAIL '\-MAX. RAIL SPAN 4.7"(MAX) z CANTILEVER 16" BETWEEN L-FEET 48" FROM PANEL EDGE 5116"X4"S. .LAG REW MIN 2.5"EMBEDMENT SEALED WITH GEOCEL FLASHING RAIL POSITION PLAN VIEn MOUN1'dTING DETAIL 3 SCALE 1'z VSCALE.3'= cCC*l FDaQATION VEREIN OCNTUNED sfULL NOT JOB REFERENCE: 1902-Resi-W OWNER Muspratt,Ashley and Matt SYSTEM SIZE: 9.72 kW DC �scR��wN. V I a,Te Rtti. awiELue 1Ncer, 11 '74- TH SSUUFsMMSDDAUSED FOR Ruc�TSN�AUITITBEaSa� MOUNTING SYSTEM SnapNRackRacking/SunModoFlashing 15 Franklin St MONITORING: SolarEdge Revenue 1G1N°� swto,e A SunBu TOOTHERS OUTSIDE CiSWl91G Sam LLC, vnTHMCaIWCIRINCCNNECTar,vAT"THE Northarrpton,MA01060 UTILITY: NGdd Hyn.�awA 312 s„EAND USE OFTHE RESIECTINE&J"MSCLAR MODULES: LG 360Ne0NR <tu�y..0 LLC SYSTEM T.ry1n 3838 F(8171112.3082 INVERTER: SolarEdge SE7600H-US RGM SHEET TITLE:MOUNTING PLAN SHEET NUMBER:5 ..a9w..� MOUNTING PLAN MP2 SNR END CLAMP V MODULE TYP. [FLASHING ,RAFTER SNR MID CLAMP -L-FOOT ,/ SNR RAIL � R`The MOUNTING METHOD I I SCALE I._,.d G q r z NR END CLAMP 6.00„ PVM DULE i SNAPNRACK RAIL +I L-FO T 1 I \ 5116"X4" . .LAG SCREW `MAX. RAIL `MAX. RAIL SPANAIL POSITION SEALEDWIMIN TBEDMENT HGEOCEL CANTILEVER 16" BETWEEN L-FEET 48" 7.9°(MIN)-15.7"(MAX) FLA HIN FROM PANEL EDGE RAIL POSITION PLAN VIEV M MOUNTING DETAIL n SCALE 1'=1'd I SCALE,7=1'Q qCONFI OWNER: REVISIONS FTM DESICNSDRAGBYTH . ORMATIONHEREINCGrrtar�SwAunGr SOB REFERENCE: 1902-Resi-W Muspratt,Ashley and Mad SYSTEM SIZE: 9.72 kVVDC DESalvnar I DATE Rei: BE USEDFOR THE BENEFIT OF ANYONE EXCEPTIGINAL IW2612RIIII A SINM SOLAR LLC,NCR SHALL IT BE DISCLOSED MOUNTING SYSTEM SnapNRack Racking/SunModo Flashing 15 Franklin St MONITORING: SolarEdge Revenue Grade Monitoring SunRuq' TO OTHERS OUTSIDE OF SUNBUG SOAR LLC. WITHOUT ca+serrORINCONrECTIDHvnTHTHE NoAhampton,MA01060 UTILITY: NGrid n+AHVHwA�.s�roe+z SALE um USE OF ME RESPECTIVE SUNBGSOLAR MODULES: LG 360NeONR LLC SYSTEM T:IB17I SfIP]81M F.IMITI 4I2�OBz INVERTER: SolarEdge SE760OH-US RGM SHEET TITLE:MOUNTING PLAN SHEET NUMBER:6 MOUNTING PLAN MP2 (TILT-UP) PV MODULE / \\ "0D' SNR END CLAMP / \\ SNAPNRACK RAIL \ L-FOOT LID L-FOOT FLASHING SNAPNRACK RAIL STANDOFF / CUT TO LENGTH ON SITE \ / 5/16"X4"S.S.LAG SORE \\ / MIN 2.5"EMBEDMENT \ SEALED WITH GEOCEL \ co, 3011 M TING DETAIL 2 \ 2xQTRUss 110011- CONFIDENTIAL oaFCO FIDENTIAL JOB REFERENCE: 1902-Resi-W OWNER: Muspratt,Ashley and Matt SYSTEM SIZE: 9.72 kW DC DESLRIFMoN. REVISI N DATE REV � NDBY: THE INFORMATION HEREIN OONTPINED SHALLNOT LABBE BE USED FOR THE BENEFIT OF ANYONE"CFPf NPL 7182018 A SoleucSOLARLLC,NORSNaLLITSEDISOWSED MOUNTING SYSTEM SnapNRackRacldng/SunModoFlashing 15FranMinSt MONITORING: SolarEdgeRevenueGradeMonRodng 8U TOOTIERS OUTSOEOF W"SOLAR I.I.C. un WTHOUTCONSENT ORINCONNECTION WTH71 MODULES: LG 360Ne0NR NoAharrpton,MA01060 UTILITY: NGrid „,A,pN„„µ19,,,,,2 SALE AND USE OF THE RESPECTIVESU NSM SBIID SOLAR Smrvi4.Bu W.LLL SYSTEM T:(617) M F.(01),12 0 INVERTER: SolarEdge SE760OH-US RGM SHEET TITLE:MOUNTING PLAN SHEET NUMBER:7 ,_ BOND#8 GEC TO TWO Panel Info Tim-Io:Supptf tilde Csmaetlon �1 Sola1B -US L Ewronlo L 1C-AS Caisuit Pro)ed Mwww GROUND RODS AT PANtL WW2P MMn breaker 10000 W,2'OV,W%,JRPCI 360 W 337.6 w PTC MqE ater MNumber 74367450 Imr 1: DC Ur4panx%d Ira 2 VOC: 43 Vpmsu: 36 5 Rated Main Panty Sery tim Entrance Owe,rhead lac Ard Iris Are Stiorm in tNe DC stri Soladeck Junction Box MP1:1x9 LG360 PANELS (E)WIRING 60A Fused fiOA Unfused Inverter 1 z 3 With 1X9 1370 AC Discolned SMART PRODUCTION 200A0 s 4 3 AC Disconnect 3 SIE aaoo�us � OPTIMIZERS � METER SOCKET -------------------------------- _---- Ecc __—___-___________ ______ ---_______________ A LI 60A0 r MP1:1x9 LG360 PANELS 1 With 1X9 P370 (E)LOADS cNo __ cc. OPTIMIZERS Pyi �--_____ __________________U i I oc DC DISCONNECT 14132:1x9 LG360 PANELS 1 With 1X9 P370 i I OPTIMIZERS h , t o H'.GGEC 1 � I '---- ----- ---- ----- -- ----- ---- �C-----------------*� I I - I ' Solaceck JunctionGEC - -T-� Junn Box rotmnAou ' ' SINGLE PHASE I I I I 11 1 Trench,wC Bch 90 UTILITY SERVICE 1 I 1 1 1 1 1 I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN SE10000HALS STRING RMIRENOM MINIMUM LENGTH: 8 OPTIMIZERS MAXIMUM POWER: 6000 WATTS 4 (3)AWG#6,THW*2 Vmp-240V Imp 42 A 3 (3)AWG#6,THWN-2 Vmp-240V Imp= 42 A 2 (2)AWG#10,THWN-2 Voc=480 Ise=15 1 (2)AWG#10,PV Wire Voc=480 Isc= 15 (1)AWG#10,THWN-2,EGC/GEC Grid (1)AWG#10,THWN-2,EGC/GEC Grid 2o R 6. (1)AWG#10,THWN-2,Grid Vmp=480 Imp= 6 10 a(1)AWG#6,Bare Cu EGLVMP= 480 Imp=6.67 o 3/4•conduit o 3/4•conduit 3/4•conduit/1•PVC comMt ;P ;V 5 (3)AWG#6,THWN-2 Vmp-240V Imp• 42 A (1)AWG#6,THWN-2 GEC Gnd 0 3/4•condult OWNER: VII DESIa16oRAF BT: CONFIDENTIAL N nnowNEaoNcoNrara®suuNor JOB REFERENCE: 1902-Resi-W Muspratt,AshleyandMatt SYSTEM SIZE: 9.72 kW DC DESCRIPTION: wTe IDANIELTH BE USED FOR THE BENEFIT OF ANYCNEIXCEPT IGINAL 1IN&BSLNBUGm1ARLLC,NORSHALLITBEDISCLOSEn MOUNTING SYSTEM SnapNRackRacking/SunModoFlashing 15 Franklin St MONITORING: SolarEdgeRevenueGradeMonitodng NaEarETtcHArlcE narmle 11nButC , TO OTHERS OUTSIDE OF SUNBUG Sant Luc. IVITHOUrcaase+TORINCCNNECTIONNTHTHE Northampton,MA 01 MO UTILITY: NGdd a,1AHt—A..s-312 suEANDUSEOFTHERESPECTIV=suNMSOLAR MODULES: LG 360Ne0NR LLC SYSTEM T(617)5 36 F:(61])a12M INVERTER: SolarEdge SE10000H-US RGM SHEET TITLE:ELECTRICAL DIAGRAM SHEET NUMBER: 1 AMrl' n EAH Structural Consulting 11 Ponvbrook Lane Lexington, MA 172421 T y PHONE 1.928.406.8921 EAH CONSULTING ElainecWEA.Hstructural.com September 18, 2018 To: Sunbug Solar 411A Highland Ave Somerville, MA 02144 Subject: Structural Certification for Installation of Solar Panels Muspratt Residence 15 Franklin Street Northampton, MA.01060 To Whom It May Concern, A design check for the subject residence was done on the existing roofing and framing systems for the installation of solar panels over the roof. From a field inspection of the property,the existing roof support structures were observed by the client's auditors as follows: The roof structure of(MP1)consists of composition shingle on 1x decking that is supported by true dimensioned 2 x 3 3/4 rafters @ 24"o.c.,with true 11/8 x 4 3/4 ceiling joists @ 48"o.c..The rafters have a max projected horizontal span of 7'-2",with a slope of 40 degrees.The rafters are butt jointed at the peak and are supported at the eave by a load bearing wall. The roof structure of(MP2)consists of composition shingle on roof plywood that is supported by scissors trusses that are spaced at @ 24"o.c..The trusses have a max projected horizontal span of approximately 22'-0"between exterior load bearing walls,and a slope of 33 degrees.The top chords are 2x4 sections,the bottom chords are 2x4 sections and the web members are 2x4 sections.The truss members are connected by steel gusset plates.The max unsupported projected horizontal top chord span is approximately 4'-0". The existing roof framing system of(MP1)is judged to be inadequate to withstand the loading imposed by the installation of the solar panels.Structural reinforcement is required. New 2x4(min)x 5'-0"long collar ties shall be installed at 24"o.c.with 3-Simpson SDW 22300 screws or 6-10d nails at each end on(MP1). The existing roof framing system of(MP2)is judged to be adequate to withstand the loading imposed by the installation of the solar panels. No reinforcement is necessary. The spacing of the solar standoffs should be kept at 48"o.c.. I further certify that all applicable loads required by the codes and design criteria listed below were applied to the AEE SnapNRack solar rail system and analyzed.Furthermore,the installation crews have been thoroughly trained to install the solar panels based on the specific roof installation instructions developed by AEE SnapN Rack for the racking system and AEE for the roof connections. Finally,I accept the certifications indicated by the solar panel manufacturer for the ability of the panels to withstand high wind and snow loads. Design Criteria: • Applicable Codes=Massachusetts Residential Code,9th Edition,ASCE 7-12,and 2015 NDS • Roof Dead Load=9 psf(MPI) -- 7 psf(MP2) • Roof Live Load=20 psf • Wind Speed=117 mph,Exposure B • Ground Snow Load=40 psf - Roof Snow Load=35 psf Muspratt Residence, Northampton 1 EAH Structural Consulting t t N'_; 11 Ponybrook Lane 07 Lexington, h1h 02421 PHONE 1.978.406.8921 Elaine(t EAHstructural.com EAH CONSULTING Please contact me with any further questions or concerns regarding this project. Sincerely, oa����t+OFAf4 .� ELAINE A. GN c HUAl CIVIL y Elaine Huang, P.E. o �No 49029Q Project Engineer /ANAL ENG Muspratt Residence, Northampton 2 E.AH Structural Consulting r 11 Ponvbrork Lane Lexington; MA 02421 PHONE 1.973.406.5921 EAH CONSULTING Elainec�EAHstructural,com Gravity Loading Roof Snow Load Calculations p9=Ground Snow Load= 40 psf pf=0.7 Ce Ct I p9 (ASCE7-Eq 7-1) CB=Exposure Factor= 1 (ASCE7-Table 7-2) Ct=Thermal Factor= 1.1 (ASCE7-Table 7-3) 1=Importance Factor= 1.1 pf=Flat Roof Snow Load= 35.0 psf PS=Cspf (ASCE7-Eq 7-2) Cs=Slope Factor= 1 p$=Sloped Roof Snow Load= 35.0 psf PV Dead Load=4 psf(Per Sunbug Solar) Roof Dead Load(MP1) Composition Shingle 4.00 1x Decking 3.00 2 x 3 314 Rafters @ 24"o.c. 1.05 Vaulted Ceiling 0.00 (Ceiling Not Vaulted) Miscellaneous 0.95 Total Roof DL(MP1) 9.0 psf DL Adjusted to 40 Degree Slope 11.7 psf Roof Dead Load(MP2) Composition Shingle 4.00 Roof Plywood 2.00 2x4 Top Chords @ 24"o.c. 0.73 Vaulted Ceiling 0.00 (Ceiling Not Vaulted) Miscellaneous 0.27 Total Roof DL(MP2) 7.0 psf DL Adjusted to 33 Degree Slope 8.35 Muspratt Residence, Northampton 3 E.AH Structural Consulting 11 Ponybrook Lane Lexington; MA 02421 PHONE 1.978.406.8921 EAH CONSUL_TINQ Elaineic)EAHstructural.com Wind Calulations Per ASCE 7-12 Components and Cladding Input Variables Wind Speed 117 mph Exposure Category B Roof Shape Gable/Hip Roof Slope 40 degrees Mean Roof Height 20 ft Building Least Width 40 ft Effective Wind Area 17.5 ft Design Wind Pressure Calculations Wind Pressure P=qh*(G*Cp) qh=0.00256*Kz*Kzt*Kd*V"2*I (Eq_6-15) Kz(Exposure Coefficient)= 0.7 (Table 6-3) Kzt(topographic factor)= 1 (Fig.6-4) Kd(Wind Directionality Factor)= 0.85 (Table 6-4) V(Design Wind Speed)= 117 mph I Importance Factor= 1 (Table 6-1) qh= 20.85 Standoff Uplift Calculations Zone 1 Zone 2 Zone 3 Positive GCp= -0.90 -1.10 -1.10 0.85 (Fig.6-11) Uplift Pressure= -18.77 psf -22.94 psf -22.94 psf 17.7 psf X Standoff Spacing= 4.00 4.00 4.00 Y Standoff Spacing= 2.75 2.75 2.75 Tributary Area= 11.00 11.00 11.00 Footing Uplift= -206 lb -252 lb -252 lb Standoff Uplift Check Maximum Design Uplift=-252 Ib Standoff Uplift Capacity = 400 Ib 400 Ib capacity>252 Ib demand Therefore,OK Fastener Capacity Check Fastener= 1 -5116"dia Lag Number of Fasteners= 1 Embedment Depth= 2.5 Pullout Capacity Per Inch= 250 Ib Fastener Capacity= 625 Ib w/F.S.of 1.5= 417 Ib 417 Ib capacity>252 Ib demand Therefore,OK Muspratt Residence, Northampton 4 EAH Structural Consulting ` 11 Pon -brook Lane Lexington, NIA 02421 PHONE 1.970.406.8921 EAH CONSULTING ElainetEAHstructural.com Framing Check (m) PASS W=101 plf Dead Load 11.7 psf PV Load 4.0 psf Snow Load 35.0 psf .._ Governing Load Combo=DL+SL < Member Span=T-2" Total Load 50.7 psf Member Properties Member Size S(in^3) I(in^4) Lumber Sp/Gr Member Spacing 2 x 3 3/4 4.69 8.79 HF#1 @ 24"o.c. Check Bending Stress Fb(psi)= fb x Cd x Cf x Cr (NDS Table 4.3.1) 975 x 1.15 x 1.3 x 1.15 Allowed Bending Stress=1676.2 psi Maximum Moment = (wL^2)/8 = 651.627 ft# = 7819.52 in# Actual Bending Stress=(Maximum Moment)/S =1668.2 psi Allowed>Actual--99.6%Stressed -- Therefore,OK Check Deflection Allowed Deflection(Total Load) = U180 (E= 1500000 psi Per NDS) = 0.477 in Deflection Criteria Based on = Simple Span Actual Deflection(Total Load) _ (5*w*L^4)/(384*E*I) = 0.457 in = U189 > U180 Therefore OK Allowed Deflection(Live Load) = U240 0.358 in Actual Deflection(Live Load) _ (5*w*L^4)/(384*E*I) 0.316 in U273 > U240 Therefore OK Check Shear Member Area= 7.5 in"2 Fv(psi)= 150 psi (NDS Table 4A) Allowed Shear = Fv*A = 1125 Ib Max Shear(V)=w*L 12 = 3641b Allowed>Actual--32.4%Stressed -- Therefore,OK Muspratt Residence, Northampton 5 .t EAH Structural Consulting 11 Ponvbrook Lane Lexington, MA 02421 PHONE 1.973.406.8921 EAH CONSULTING Elaine tiEAHstructural.coni Framing Check (MP2) PASS w=95 plf Dead Load 8.3 psf PV Load 4.0 psf Snow Load 35.0 psf Governing Load Combo=DL+SL Member Span=4'-0" Total Load 47.3 psf Member Properties Member Size S(in^3) I(in"4) Lumber Sp/Gr Member Spacing 2x4 3.06 5.36 SPF#2 @ 24"o.c. Check Bending Stress Fb(psi)= fb x Cd x Cf x Cr (NDS Table 4.3.1) 875 x 1.15 x 1.5 x 1.15 Allowed Bending Stress=1735.7 psi Maximum Moment = (wL^2)/8 = 189.386 ft# = 2272.63 in# Actual Bending Stress=(Maximum Moment)/S =742.1 psi Allowed>Actual-42.8%Stressed -- Therefore,OK Check Deflection Allowed Deflection(Total Load) = L/180 (E=1400000 psi Per NDS) = 0.266 in Deflection Criteria Based on = Continuous Span Actual Deflection(Total Load) _ (w*L"4)/(185*E*I) = 0.031 in = L/1549 > U180 Therefore OK Allowed Deflection(Live Load) = L/240 0.2 in Actual Deflection(Live Load) _ (w*L"4)1(185*E*1) 0.023 in U2087 > U240 Therefore OK Check Shear Member Area= 5.3 in12 Fv(psi)= 135 psi (NDS Table 4A) Allowed Shear = Fv*A = 709 Ib Max Shear(V)=w*L/2 = 189 Ib Allowed>Actual--26.8%Stressed -- Therefore,OK Muspratt Residence, Northampton 6 I r - — I (9 LG Innovation Life's Good a Better Life W. LG NeON. R MMMEllevi-Vis .. The LG NeONO R is a powerful solar module that provides world-class performance.A new cell structure that eliminates electrodes on the 60 cell front maximizes the utilization of light and enhances reliability.The '' C E LG NeONO R is a result of LG's efforts to increase customer value pVE `;` V$ \" beyond basic efficiency.The NeONO R features enhanced durability and performance under real-world conditions,an enhanced warranty and an aesthetic design suitable for roofs. 0� Enhanced Performance Warranty .� High Power Output LG offers a 25 year product warranty for LG NeON®R, The LG NeONO R has been designed to including labor,in addition to an enhanced performance significantly enhance its output;making it efficient warranty.After 25 years,LG NeONO R is guaranteed to even in limited space. produce at least 88.4%of its initial power output. Roof Aesthetics ® Outstanding Durability LG NeONO R has been designed with aesthetics in mind: With its newly reinforced frame design,LG the lack of any electrodes on the front creates an NeONO R can endure a front load up to 6000 Pa, improved,modern aesthetic. and a rear load up to 5400 Pa. • • Near Zero LID(Light Induced • - Better Performance on a Sunny Day LLG NeONO R now performs better on sunny Degradation) days,thanks to its improved temperature coefficient. The n-type cells used in LG NeON®R have almost no boron.This leads to less LID(Light Induced Degradation)right after installation. About LG Electronics LG Electronics is a global player who has been committed to expanding its capacity,based on solar energy business as its future growth engine.We embarked on a solar energy source research program in 1985, supported by LG Group's rich experience in semi-conductor,LCD,chemistry,and materials industry.We successfully released first Mono Xe series to the market in 2010,which were exported to 32 countries in the following 2 years,thereafter.In 2013,NeONT"(previously known as Mono X•NeON)&2015 NeON2 with CELLO technology won"Intersolar Award",which proved LG is the leader of innovation in the industry. LG NeON® R •• Mechanical Properties Electrical Properties(STC*) Cells 6 x 10 Module 365 360 355 350 Cell Vendor LG Maximum Power(Pmax) 365 360 355 350 Cell Type Monocrystatline/N-type MPP Voltage(Vmpp) 36.7 36.5 36.3 36.1 Cell Dimensions 161.7 x 161.7 mm/6 inches MPP Current(Impp) 9.95 9.87 9.79 9.70 Dimensions(L x W x H) 1700 x 1016 x 40 mm Open Circuit Voltage(Voc) 42.8 42.7 42.7 42.7 66.93 x 40.0 x 1.57 inch Short Circuit Current(Isc) 10.8 10.79 10.78 10.77 Front Load 6000Pa Module Efficiency 21.1 20.8 20.6 20.3 Rear Load 5400Pa Operating Temperature -40-+90 Weight 18.5 kg Maximum System Voltage 1000 Connector Type MC4 Maximum Series Fuse Rating 20 Junction Box IP68 with 3 Bypass Diodes Power Tolerance(%) 0-+3 Length of Cables 1000 mm x 2 ea •STC(Standard Test Condition):Irradiance 1,000 W/m',Ambient Temperature 25"C,AM 1.5 Glass Tempered Glass with AR Coating *The nameplate power output is measured and determined by LG Electronics at its sole and absolute discretion. •The typical change in module efficiency at 200 W/m'in relation to 1000 W/m'is-2.0%. Frame Anodized Aluminium Electrical Properties(NOCT*) Certifications and Warranty Module 365 360 355 350 Certifications IEC 61215,IEC 61730-1/-2 Maximum Power(Pmax) 275 271 267 263 UL 1703 MPP Voltage(Vmpp) 36.6 36.4 36.2 36.0 IEC 61701 (Salt mist corrosion test) MPP Current(Impp) 7.51 7.45 7.39 7.32 IEC 62716(Ammonia corrosion test) Open Circuit Voltage(Voc) 40.2 40.2 40.2 40.1 ISO 9001 Short Circuit Current(Isc) 8.70 8.69 8.68 8.67 Module Fire Performance(USA) Type 1 •NOCT(Nominal Operating Cell Temperature):Irradiance 800 W/m',ambient temperature 20°C,wind speed 1 m/s Fire Resistance Class(CANADA) Class C(ULC/ORD C1703) Product Warranty 25 years Output Warranty of Pmax Linear warranty** Dimensions(mm/in) **1)First 5 years:95%,2)After 5th year:0.4%annual degradation,3)25 years:88.4% Temperature Characteristics \� \ \ _I NOCT 44 t 3`C Pmpp -0.30%/`C Voc -0.24%/`C Isc 0.04%/`C ro.•i� R wwro Characteristic Curves „ 1000W w.. ....gym. a 10.00 nnW 8.00 6.00 4.00 200 ._........ __ .__...... ..,_2QQW----_ ... _.._.,_... iI )I Vdtage(V) 8a 0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 140 E120 - ----------- - a 100 - >° u eo - -- --- r+1ir: a40 ----------------------------------------------------------------------------------------- I 20 ----- 0 Temperature(Y) o u 0 25 50 75 so •The distance between the center of the mounting/grounding holes. ® LG North America Solar Business Team Product specifications are subject to change without notice. LG Electronics U.S.A.Inc DS-T1-72-W-G-P-EN-60630 Lifes Good 1000 Sylvan Ave,Englewood Cliffs,NJ 07632 Copyright©2017 LG Electronics.All rights reserved. innovation for a Better Life Contact:Ig.sclar@Ige.com 01/01/2017 www.igsolarusa.com (9 LG Life's Good LG SOLAR MODULE LIMITED WARRANTY The limited warranties specified below (hereinafter"Limited Warranty") apply to LG Solar Module models listed under Section 11 below (hereinafter "Module(s)") sold by LG Electronics U.S.A., Inc. (hereinafter "LG") and installed by a licensed contractor in applicable local and state laws,and extend only to the original end use purchaser and subsequent owner(s)of the facility/project site at the location on which the Module(s) is originally installed (all such persons hereinafter referred to as "Customer"). The warranty start date("Warranty Start Date")shall be the date of purchase by the original end use purchaser.If the Customer is unable to provide adequate documentation of the original purchase, the Warranty Start Date shall be ninety (90) days after the Module(s) was manufactured. 1. 25 Years Limited Warranty for Module(s) LG will, at its sole option, repair or replace the Module(s)if it proves to be defective in material or workmanship for a period ending 25 years from the Warranty Start Date under normal application, installation, use and service conditions. 2. 25 Years Limited Warranty for Power Output LG warrants that for a period of one(1)years from Warranty Start Date the actual power output of the module will be no less than 98% of the labeled power output.From the second year,the warranty for power output will decline annually by 0.4%in each of the remaining 24 years,so that during the 25th year, an actual output of at least 88.4%of the nameplate power output specified on the Module will be achieved.The power output values shall be those measured under LG's standard test conditions as follows: (a) light spectrum of AM 1.5; (b)an irradiation of 1000 W per m2 and; (c)a cell temperature of 25 degrees centigrade at right angle irradiation. If the Module does not meet the warranted power output levels set out above when measured by LG or by an independent measuring institute agreed to prior to testing by LG under standard test conditions(IEC 61215)taking into account a t3%measurement tolerance range, LG will,at its sole and absolute discretion,either(i)repair the Module(s);(ii)supplement such deficiency in power by either: (a) providing additional Module(s) to the Customer, or (b) replacing the Module(s); or (iii) Refund the difference between guaranteed minimal power output and actual power output(measured under LG's STC)multiplied by the then current market price of the Mod ule(s) or a comparable model at the time of the Customer's claim. 3. How this Limited Warranty Applies The remedies set forth in this Limited Warranty shall be the sole and exclusive remedies,and the original warranty period in this Limited Warranty shall not extend beyond the period set forth therein, nor will a new warranty period begin, upon repair, replacement or pro- rated refund due to power loss at LG's sole option provided under this Limited Warranty. Repair or replacement will be made with new or re-manufactured Module(s)or parts and the replaced Module(s)or parts shall become the property of LG. In the event the Module(s) is no longer available, LG reserves the right, at its sole option, to deliver new or remanufactured Module(s)that may differ in size, color, shape, model number, and/or power level. LG Solar Module(s)Warranty, Rev.180501 1 /4 www.Ig-solar.com (9 LG Life's Good This Limited Warranty covers the transportation cost for reshipment of any repaired or replaced Module(s)to the Customer site, but does NOT cover the transportation cost and risk including shipping damage or loss for return of the Module(s)to LG or LG's authorized agent and any other costs associated with installation, removal,or re-installation of the Module(s). In the event a Module fails to meet the Limited Warranty as detailed in Sections 1 and 2 hereof, LG,at its sole discretion,may support the Truck Roll cost directly resulting from removal or re-installation of Module(s) up to $450 (i.e., $350 for the first visit and $100 for the second visit). If Module(s) returned to LG is not found to be defective or this Limited Warranty has expired, the Customer is responsible to pay for the shipping cost associated with returning such Module(s). 4. Limited Warranty Exclusions 4-1. This Limited Warranty does NOT apply to Module(s): (a) Sold and/or installed outside the geographic territory of the United States and US territories; (b) Sold AS IS or WITH ALL FAULTS or consumables; or (c) That had a serial number or any part thereof altered, defaced or removed. 4-2. This Limited Warranty also does NOT apply to Module(s)which have been subjected to: (a) Damage and/or failure caused by use on a mobile unit including, but not limited to,vehicles,vessels,etc.; (b) Damage and/or failure caused by non-compliance with national and local electric codes; (c) Damage and/or failure caused by installations not in conformance with the Module(s)specifications,installation manuals,operation manuals,or labels attached to the Module(s); (d) Damage and/or failure caused by improper wiring, installation,or handling; (e) Damage and/or failure caused by devices and/or parts other than the Module(s)or by mounting methods of such devices and/or parts; (f) Damage and/or failure caused by improper or incorrectly performed maintenance,operation or modification; (g) Damage and/or failure caused by removal from the original place of installment; (h) Damage and/or failure caused by repairs not in accordance with LG's instructions; (i) Damage and/or failure caused by inappropriate handling during storage, packaging or transportation; (j) Damage and/or failure caused by external shock such as flying objects or external stress; (k) Damage and/or failure caused by direct contact with environmental pollution such as soot, acid rain or industrial chemicals Including ammonia; (1) Damage and/or failure caused by direct contact with salt water; (m) Damage and/or failure caused by natural forces(earthquakes,tornados,floods, lightning, hurricanes, heavy snow, etc.)and fire, Power failures, power surges or other unforeseen circumstances that are beyond LG's control; (n) Damage and/or failure caused by terrorist acts, riots,war or other man-made disasters; LG Solar Module(s)Warranty, Rev.180501 2/4 www.Ig-solar.com (OLG Life s Good (o) Damage and/or failure caused by external stains or scratches that do not affect output; (p) Damage and/or failure caused by sound,vibration, rust,scratching,or discolorations that are the result of normal wear and tear, Aging or continuous use;or (q) Damage and/or failure caused by Module(s)installed in a location that exceeds operating conditions. 5. Limitation of Warranty Scope EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THE MODULE(S)IS LIMITED IN DURATION OF THIS LIMITED WARRANTY. UNDER NO CIRCUMSTANCES SHALL LG BE LIABLE FOR ANY INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING, WITHOUT LIMITATION, LOST GOODWILL, LOST REVENUES OR PROFITS, WORK STOPPAGE, MODULE(S) FAILURE, IMPAIRMENT OF OTHER GOODS, COSTS OF REMOVAL AND REINSTALLATION OF THE MODULE(S), LOSS OF USE,INJURY TO PERSONS OR PROPERTY ARISING OUT OR RELATED TO THE MODULE(S). LG'S TOTAL LIABILITY,IF ANY, DAMAGES OR OTHERWISE,SHALL NOT EXCEED THE INVOICE VALUE PAID BY THE CUSTOMER FOR THE MODULE(S)OR SERVICE(S)FURNISHED,WHICH IS THE SUBJECT OF A CLAIM OR DISPUTE. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS,SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS LIMITED WARRANTY GIVES THE CUSTOMER SPECIFIC LEGAL RIGHTS;CUSTOMERS MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE. 6. Assertion of Claims The assertion of claims under this Limited Warranty presupposes that the Customer has(i)informed the authorized reseller/distributor of our Module(s)in writing of the alleged claim,or that;(ii)this written notification has-been sent directly to the address stated in Section 7 below in the event that the authorized reseller/distributor no longer exists (e.g. due to discontinuance of business or bankruptcy). Any such assertion of claims must be accompanied by the original sales receipt as the proof of purchase and time of purchase of LG Module(s).The assertion of the claim must occur within thirty(30)days from the date that the claim is identified.The return of Module(s) may only occur after the written authorization of LG has been given. 7. Obtaining Warranty Performance Customers who believe they have a justified claim covered by this Limited Warranty must immediately notify the authorized LG representative, or contact LG directly by writing to: LG Electronics U.S.A. Inc. Solar Business Team 1000 Sylvan Ave. Englewood Cliffs, NJ 07632 LG Solar Module(s)Warranty, Rev.180501 3/4 www.ig-solar.com (9 LG Life's Good Email: Ig.solar@lge.com Customer may also contact LG via its web-site at www.igsolarusa.com. 8. Force Majeure LG shall not be responsible or liable to Customer or any third party for any non-performance or delay in performance of any terms and conditions of sale, including this Limited Warranty,due to acts of God,war,strikes, riots, unavailability of suitable and sufficient labor, material, capacity, technical, yield failures or any other unforeseen event beyond LG's control, including, without limitations, any technological,physical event or condition which is not reasonably known or understood at the time of sale of the Module(s)or the claim. 9. Disputes Except to the extent prohibited by applicable law,the Customer agrees she/he will not bring any action, regardless of form, arising out of or in any way connected with this Limited Warranty, more than one(1)year after the cause of action has occurred. 10. Severability If a part, provision or section of this Limited Warranty, or its application to any person or circumstance is held invalid, void or unenforceable,such holding shall not affect this Limited Warranty and all other parts, provisions,clauses or applications shall remain, and,to this end,such other parts, provisions,clauses or applications of the Limited Warranty shall be treated as severable. 11. Validity This Limited Warranty is valid from May 1, 2018 sold to specific Customer(s)and shall apply to below Modules of the serial number starting with 707Kxxxxxxxx which manufactured after July 1,2017. 1'LGxxxQxx-A5" LG holds the right to amend the provisions, clauses or applications of this Limited Warranty from time to time without notice; however such changes would not be retrospective. LG Solar Module(s)Warranty, Rev.180501 4/4 www.ig-solar.com solar=@ " • Single Phase Inverter with HD-Wave Technology • for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US / SE1000OH-US 0 00 r • �alarE ,.+�.,.� � ' I O in 71 t ZEN K" g v t • a Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2414 and 2017,per article 690.11 and 690.12 UL1741 SA certified,for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring %tn, Outdoor and indoor installation wave Optional:Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) www.solaredge.us so I a r ' • • Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/SE380OH-US/SE5000H-US/ SE6000H-US/SE760OH-US/SE1000OH-US SE3000H-US SE 9 14-US SES000H-US SE6000H-US SE7600H-US SE10000H-US J OUTPUT Rated AC Power Output 3000 3800 @ 240V 15000 6000 @ 240V 760010000 VA ._............ .......... 3300 208V 5000, 208V -.800 @°......................... @.2400.................. ..................f......... Max.AC Power Output 3000 5000 7600 10000 VA 3800 @ 240V � i 6000 @ 240V ! P................................... ................ 3300,@ 208V..j................ .5000 @,208y ................�.................. ......... AC Output Voltage Min.,Nom:Max.(183:208 ✓ ✓ ., ,,,,.,. Vac AC Output VoltageMrn Nom Max (211 240„264)- ✓ ✓,.-.•.,., ,,,_,✓,.___.-I._.....�........ ............. �........i. _._...._.... ........ AC Frequency(Nominal) 59.3-60-60.50) „ Hz ................ ................ Maximum Continuous Output Current208V 16 { 24 � -.-. A_-. ............. .................... :.._....., Maximum Con tinuousOutputCurrent@240V 12:5 16 21.. ... ,,,,,,25 i . ...32.... ..�...... 42....... ...A.... ... .. GFDI Threshold „. ................ 1 _ A Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 ; - .7750 9300 11800 1550.0 W ....t............ ............. .. Maximum DC Power @208V i 5100 j 7750 ............................. _. Transformer-less,Ungrounded Yes .......... _.... _..... . ......._ Maximum In ut Voltage „ „ 480 Vdc P.. .. Nominal DC Input Voltag?............................. 380 _.........400 Vdc .. . . .. . Maximum In ut Current 208V 9 I 13.5 Maximum Input Current @240V 8.5 .. .1.... ...... 13:5 165 ......20.•.....x.......27 Adc Max;Input Short Circuit Current 45....,..„ +„Adc ..................... ....................... ................ Reverse Polarity Protection Yes •••-„-„ ..... ....... ........................................................................................... Ground-Fault Isolation Detection600kstSensitivity................................ j...... ,.. ............................... ..................... ...... Maximum Inverter Efficiency......... .. 99 99.2 %.... ....I......... CEC Weighted Efficiency. 99 Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES _-- .Supported Communication interfaces. • ... .... . ... RS485,Ethernet,ZigBee(optional)t Cellular(optional)......... ......... ............ Revenue Grade Data,ANSI C12.20 Optionaltll ... ........ ... ........ ......... ......... ................ ......... to. is .nnec.. Rapid Shutdown-NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect ^_ STANDARD COMPLIANCE --- -------------- ---------------------- Safety „-„- , U11741,UL17415A,l)L16998,CSA C22t2,Canadian AFCI according to T.I,L.M-07 ......... ............i......... GFidConnectionStandards („ ,_,. IEEE1547,Rule21,,Rule 14(HI).. Emissions — Y _ FCC Part 15 Class 8 INSTALLATION SPECIFICATIONS T___._-_____ --- ------- ---- ACOutputConduitSize(AWGRange,,, , 3/4"minimum/20-4 ,AWG „•-„•,,, ....................... . 3/4”minimum DC Input Conduit Size/N of Strings/AWG Range 3/4"minimum/1-2 strings/14-6 AWG /1-3 strings/ 14 6 AWG 21.3 x 14.6 '! i n/ Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 x 7.3/540 x mm ................... ................................... ......... Weight with Safety Switch ............. ............ 2211-10........ <25 25.1 I...........26.2/11.9 <I50 38;8/.17:6.. lbkg. Noise ...................................................... .. .............................................. ........................{...................................;...... Natur Cooling,. .............................................. Natural Convection -'-...I........ l convection.... -13 - ( .........,P � Operating Temperature Range „ -13 to+1.. .-25 to...... 40°F/ 40'C o tion l^I Protection Rating „ -•-,- ,...... ....... NEMA 3R(Inverter with Safety Switch) ......... . For other regional settings please contact SolarEdge support o�Revenue grade inverter P/N:SEMXH-USOOONNC2 (')For power de-rating Information refer to:https://www.solamdge.com/sites/default/files/se-temperature-derating-note-na.pdf (')-40 version P/N:SExxxxH-USOOONNU4 • solar - . . SolarEdge Power Optimizer Module Add-On For North America P320/ P370 / P400 / P405 / P505 • • �ws u ;S�rtr_ �P x , t i k r v :.nom . r".:' PVpa VW � lf1# SpecificaNy designed to work with SolarEdge Inverters - Up to 25%more energy Superior efficiency(99.5%) Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module-level monitoring Compliant with arc fault protection and rapid shutdown NEC requirements(when installed as part of the SolarEdge system) Module-level voltage shutdown for installer and firefighter safety USA-CANADA-GERMANY-UK-ITALY-THE NETHERLANDS-JAPAN-CHINA-AUSTRALIA-ISRAEL-FRANCE-BELGIUM-TURKEY-INDIA-BULGARIA-ROMANIA-HUNGARY- WWW.SOIafedge.US SWEDEN SOUTH AERICA-POLAND-CZECH REPUBLIC so I a r - • -• ! SolarEdge Power Optimizer Module Add-On for North America P320/ P370/P400/ P405/P505 OPTIMIZER MODEL P320 (forhP370 igher-power P400 P405 P505 (for high-power (tor 72&96-cell ' (for thin film (for higher (typical module compatibility) 60-cell modules) 60 and 72-ce8 modules) modules) current modules) modules) INPUT _ p... ..Rated to ut DC Power''I ........ .... 370 ..... ..........0 ......... 0 ...... ......... 0 ..... ... W ...... Absolute Maximum input Voltage �$ 60 80 125 83 Vdc (Voc at lowest temperature)---............... .................. --------------- - MPPTOperatingRan6e....... �...... 8 48.... 8-60 8.:80....._..1.....12:5:105...... ......125:.83...... ....Vdc..._. Maximum ShortCircuit Current Isc it 10.1 14 Adc ................ ...)...... ............................................. ............................................. ...................... .............. Maximum DC Input Current............... ...................13;75.................... 12.63.... 17:5......... ....Adc............. Maximum Efficiency. .. ... ......... :5.............................. _.. ... ............. Wei h qd l;ienc ..... ... ......... .... 98.8 98.6. ...... .....% ........:......y........................ ............... . .. .......................................... .....I.............. . Overvoita a Cate or 11 OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) T— __ _ _ -- _ __-_. _-_.___ T _ _. .. _ __. Maximum Output Current 15 Adc ..... ........ .................... ..... .......... ..... Maximum Output Voltage _ _ _60 _ — 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 110.1 Vdc STANDARD COMPLIANCE EMC f,,.,-.,-•---..... FCCPartiSClass..... lEC61000-62,IEC. ...0I6-3... ............... . Safety . .,_IEC62109-1(class li safety),UL1741 ............................... ....................... .............. RoHS Yes ---- ---- — — INSTALLATION SPECIFICATIONS _ __ Maximum Allowed System Voltage 1000 —Vdc ....... . .. ..... ............................---.................................. Compatible inverters All SolarEdge Single Phase and Three Phase inverters .................. ...................... .............. Dimensi ons(W x L x H) 128x152x28/5x5.97x1.1 128x152x36/ I 128x152 x50/ i 128x152x59/ mm/in Sx5.97x1.42 5x5.97 x1.96 Sx5.97x2.32 ............................................... ............................................. ...................... ...................... ...................... .............. Weisht Sincluding cables).................. .................630/.1:4.................. ......7..5.0../.1...7....... ......845./.1.9......11064/.23...... ...1; 1b.... Input Connector MC4121 Output Wire Type/Connector.......... Double Insulated;MC4....................................... .......... ................................................. . ...... Output Wire Length........................ ..... 0.95/3.0 I.........................................1:?./3:9rnt ......................................... ... ..f ... Operating Temperature Range---.-.-- 40 +85j_40-+185 ......................................•-,-- .,-`C-/`F- . Protection RatingIP68/NEMA6P Relative Humidity ..... ..................... !.........................---.-- .....................0-.100. ........ _%...... Rated STC power of the module.Module of up to+S%power tolerance allowed. lit For other connector types please contact SolarEdge PV SYSTEM DESIGN USING SINGLE PHASE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER1041 HD-WAVE Minimum String Length P320,P37.. P400...i.........................8..........................�...........19... ......,............18............ �Power O timizers P405 P505 6 8 14 .........P.........). / Maximum String length ............ 5 25 25 0'S' (Power Optimizers) .................. ............. .............................................. I 5700(6000 with Maximum Power per String SE7600H-US, 5250 6000 12750 W SEI..... US)......I..........................i.......................... ..........................j............. . SE Parallel Strings of Different Lengths Yes or Orientations .......................................................................................................................... 13j For detailed string sizing information refer to:http://�.soiaredge.com/sites/detauft/bles/Stnrig_gzing_napdf. r0I It is not allowed to mix P405/P505 with P320/P370/P400/P600/P700/P800 in one string. 's�A string with more than 30 optimizers does not meet NEC rapid shutdown requirements;sa"voltage wit be above the 30V requirement 9oIar' • • = LIMITED PRODUCT WARRANTY LIMITED PRODUCT WARRANTY This SolarEdge Technologies Ltd.Limited Warranty covers defects in workmanship and materials of the below-listed products for the applicable warranty period set out below: • Power optimizers:25 years commencing on the earlier of:(i)4 months from the date the power optimizers are shipped from SolarEdge;and(ii)the installation of the power optimizers,provided,however,that for the module embedded power optimizers(CSI and OPJ models),the Warranty Period shall not exceed the maximum of(1)the module product warranty and(2)the module power warranty periods provided by the applicable module manufacturer. • Inverters Safety&Monitoring Interface(SMI),Auto-transformer,GSM Cellular Modem:12*years commencing on the earlier of:(i)4 months from the date the products are shipped from SolarEdge;and(ii) the installation of the products. • StorEdge Interface:10 years commencing on the earlier of:(i)4 months from the date the Interfaces are shipped from SolarEdge;and(ii)the installation of the Interfaces. • Home Gateway Control and Communication Gateway,Firefighter Gateway,Wireless Communication Products excluding GSM Cellular Modem,RS485 Expansion Kit,SolarEdge Meter,Smart Monitoring Combiner Box:5 years commencing on the earlier of:(i)4 months from the date the product is shipped from SolarEdge; and(ii)the installation of the product.Warranty duration of wireless communication products is the same whether or not the product is pre-installed in the inverter. *In some countries the inverter warranty is limited to 7 years.For a list of these countries please access http://www.solaredge.com/warranty exceptions The Limited Warranty does not apply to components which are separate from the Products,ancillary equipment and consumables,such as,for example,cables,fuses,wires and connectors,whether supplied by SolarEdge or others.Some components may carry their own manufacturer warranty.See product datasheet for more details.In addition,for all power optimizers with a part number ending in C,the SolarEdge warranty does not apply to the input connector. The Limited Warranty only applies to the buyer who has purchased the Products from an authorized seller of SolarEdge for use in accordance with their intended purpose. The Limited Warranty may be transferred from buyer to any assignee,and will remain in effect for the time period remaining under the foregoing warranties,provided that the Products are not moved outside its original country of installation and any reinstallation is done in accordance with the installation directions and use guidelines accompany the Products(collectively the "Documentation"). If,during the applicable Warranty Period,buyer discovers any defect in workmanship and materials and seeks to activate the Limited Warranty,then buyer shall,promptly after such discovery,report the defect to SolarEdge by sending an email to supportPsolaredge.com with the following information:(i)a short description of the defect,(ii)the Product's serial number,and(iii)a scanned copy of the purchase receipt or warranty certificate of the applicable Product. Upon buyer's notification,SolarEdge shall determine whether the reported defect is eligible for coverage under the Limited Warranty. The Product's serial number must be legible and properly attached to the Product in order to be eligible for Warranty coverage. If SolarEdge determines that the reported defect is not eligible for coverage under the Limited Warranty,SolarEdge will notify buyer accordingly and will explain the reason why such coverage is not available. If SolarEdge determines that the reported defect is eligible for coverage under the Limited Warranty,SolarEdge will notify buyer accordingly,and SolarEdge may,in its sole discretion,take any of the following actions: • repair the Product at SolarEdge's facilities or on-site;or • issue a credit note for the defective Product in an amount up to its actual value at the time buyer notifies SolarEdge of the defect,as determined by SolarEdge,for use toward the purchase of a new Product;or • provide Buyer with replacement units for the Product. SolarEdge will determine whether the Product should be returned to SolarEdge and,if SolarEdge so determined,the Return Merchandise Authorization("RMA")Procedure(set out below)will be invoked. Where replacement Products are sent,SolarEdge generally sends such products within 48 hours.SolarEdge may use new,used or refurbished parts that are at least functionally equivalent to the original part when making warranty repairs.The repaired Product or replacement parts or Product,as applicable,shall continue to be covered under the Limited Warranty for the remainder of the then-current Warranty Period for the Product. Where the RMA Procedure is invoked by SolarEdge,SolarEdge will instruct buyer how to package and ship the Product or part(s)to the designated location. SolarEdge will bear the cost of such shipment,upon receipt of the Product or part(s),SolarEdge will,at its expense and sole discretion,either repair or replace the Product or part(s). SolarEdge General Product Warranty 1 solar • • = LIMITED PRODUCT WARRANTY ♦ SolarEdge will deliver the repaired or replaced Product or part(s)to buyer at buyer's designated location in countries where SolarEdge has an office and/or there is a significant PV market.For the specific list of countries to which such service is provided,please access http://www.solaredge.com/articles/shipping cost coverage warranty.SolarEdge will bear the cost of such shipment,including shipping and customs(where applicable)and buyer shall bear any applicable value added tax. SolarEdge may elect to ship replacement Product and/or part(s)prior to receipt of the Product and/or part(s)to be returned to SolarEdge as per the above. Where SolarEdge decides to repair the Product or part(s),warranty coverage includes labor and material costs necessarily incurred to correct the Product defect;and where SolarEdge decides to replace the Product or part(s)to which the Limited Warranty applies,warranty coverage includes the cost of the replacement of the Product or part(s). In addition,SolarEdge shall bear shipping costs in respect to the foregoing,as set out above. All other costs,including,without limitation,travel and boarding costs of SolarEdge service personnel that are incurred for repairs of Products on-site,as well as costs related to buyer's employees and contractors repair or replacement activities,are not covered by the Limited Warranty and,unless otherwise agreed in writing in advance by SolarEdge,shall be borne by the buyer. Warranty Exclusions: This Limited Warranty will not apply if(a)buyer is in default under the General Terms and Conditions of other Agreement governing the purchase of the Product,or(b)the Product or any part thereof is: • damaged as a result of misuse,abuse,accident,negligence or failure to maintain the Product; • damaged as a result of modifications,alterations or attachments thereto which were not pre-authorized in writing by SolarEdge; • damaged due to the failure to observe the applicable safety regulations governing the proper use of the Product; • installed or operated not in strict conformance with the Documentation,including without limitation,not ensuring sufficient ventilation for the Product as described in SolarEdge installation guide; • opened,modified or disassembled in any way without SolarEdge's prior written consent; • used in combination with equipment,items or materials not permitted by the Documentation or in violation of local codes and standards; • damaged or rendered non-functional as a result of power surges,lightning,fire,flood,pest damage,accident, action of third parties,or other events beyond SolarEdge's reasonable control or not arising from normal operating conditions;or • damaged during or in connection with shipping or transport to or from buyer where buyer arranges such shipping or transport. This Limited Warranty does not cover cosmetic or superficial defects,dents,marks or scratches,which do not influence the proper functioning of the Product. THE LIMITED WARRANTIES SET OUT HEREIN ARE IN LIEU OF ANY OTHER WARRANTIES WITH RESPECT TO THE PRODUCTS PURCHASED BY BUYER FROM SOLAREDGE,WHETHER EXPRESS OR IMPLIED,WRITTEN OR ORAL(INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE),ALL OF WHICH ARE EXPRESSLY EXCLUDED TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW. Claims by buyer that go beyond the warranty terms set out herein,including claims for compensation or damages,are not covered by the Limited Warranty,insofar as SolarEdge is not subject to statutory liability. In such cases,please contact the company that sold you the Product. Eventual claims in accordance with the law on product liability remain unaffected. Coverage under the Limited Warranty is subject to buyer complying with the foregoing notification requirements and cooperating with SolarEdge's directions. SolarEdge's sole obligation and buyer's exclusive remedy for any defect warranted hereunder is limited to those actions expressly stated above. Such actions are final and do not grant any further rights,in particular with respect to any claims for compensation. Unless otherwise specified in an executed Agreement with SolarEdge,the Limited Warranty and related provisions set out herein are subject to SolarEdge's General Terms and Conditions,including,without limitation,the provisions thereof,which relate to disclaimer of warranties, limitation of liability and governing law and jurisdiction. Revised:June 2016 SolarEdge General Product Warranty Snapf rack- Solar Mounting Solutions Series 100 Residential Roof Mount System The SnapNrack Series 100 UL Roof Mount System is an efficient, visually appealing, photovoltaic (PV) module installation system. Series 100 UL is listed to the UL 2703 for grounding/bonding and fire classification. The System's components provide an adequate bonding path which has eliminated the need for grounding lugs and wash- ers at each module, and bonding jumpers between splices. In addition to grounding and bonding, the roof mount system, Series 100 UL, is Class A Fire Rated when in- stalled with Type I and Type II Modules. SnapNrack's UL 2703 Certification and Com- pliance ensures that SnapNrack installers can continue to provide the best in class installations in quality, safety and efficiency. • Appealing design with built-in aesthetics • No grounding lugs required for modules • All bonding hardware is fully integrated into the components - r • Rail splices bond rails together, no rail jump- ers required ` • Proprietary SnapNrack grounding lug snaps in the rail channel • No drilling of rail or reaching for other tools required • Class A Fire Rating for Type 1 and 2 modules System Features Include Snap in Single Tool Easy No Cutting Hardware Installation Leveling or Drilling OL Integrated Wire Preassembled Integrated bonding UL 2703 Certified Management hardware Resources snapnrack.com/resources . Design configure.snapnrack.com Where to Buy snapnrack.com/buy , Snap rack- Solar Mounting Solutions Stainless Bolt with Stainless Steel SnapNrack Bonding SnapNrack Standard Rail Split-Lock Washer Bolt with Split- Splice Insert Lock Washer SnapNrack BondingSnapNrack SnapNrack Adjustable End Splice Clamp Top Bonding Base Mid Clamp SnapNrack SnapNrack Bonding Bonding qiw Adjustable End SnapNrack Stainless Bonding Channel Nut Clamp Bottom Channel Nut Stainless Hardware with Bolt with Split-Lock Washers Split Lock SnapNrack Bonding SnapNrack Bonding SnapNrack Bonding Washer Adjustable End Clamp Mid Clamp Standard Rall Splice SnapNrack Ground Lug 12-6 AWG Copper Wire SnapNrack Ground Lug Assembly (ONE REQUIRED PER ROW OF MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave UEC Pull Strap UEC Wedge Stainless Steel Bolt with Flat Washer IF IF IF IF SnapNrack Bonding Universal End Clamp SnapNrack Bonding Standoff Clamp Assembly SnapNrack Serrated Stainless_,A SnapNrack SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Rain Collar Channel Stainless Serrated Stainless Nut Flange Nut Steel Flange Bolt SnapNrack Stainless SnapNrack 92 Degree Flange Mill Finish L Foot Bolt Standoff SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff SnapNrack Base(1-Hole SnapNrack Base Shown) SnapNrack L Foot Metal Roof Mill Finish Flashing Base Assembly L Foot Base SnapNrack Bonding J SnapNrack Bonding SnapNrack MetalRoof Base with Standoff Assembly L Foot Base with Flashing Bonding L Foot SERIES • • TECHNICAL DATA • 6000 Series aluminum Materials • Stainless steel • Galvanized steel and aluminum flashing • Clear and black anodized aluminum Material Finish • Mill finish on select components • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification Caics.&Certifications • Class A Fire Rating Type 1 and Type 2 modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One lug per individual row of modules) • Integrated bonding components Warranty 10 year limited product warranty;5 year limited finish warranty 877-732-2860 www.snapnrack.com contact@snapnrack.com Snap- - ' rack- Solar Mounting Solutions Limited Warranty THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS,WHICH VARY FROM STATE TO STATE. THE LIMITED WARRANTY CAN ALSO BE FOUND ONLINE AT http://snapnrack.com/resources/brochures/any/any/snapnrack-warranty. WE LIMIT THE DURATION AND REMEDIES OF ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THE DURATION OF THIS EXPRESS LIMITED WARRANTY. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS,SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. OUR RESPONSIBILITY FOR DEFECTIVE PRODUCTS IS LIMITED TO REPAIR,REPLACEMENT OR REFUND AS DESCRIBED BELOW. WHO MAY USE THIS WARRANTY? SnapNrack,located at 775 Fiero Lane,Suite 200,San Luis Obispo,CA 93401("we")extend this limited warranty to the consumer who originally purchased the product("you").If you sell the site where our products are installed,you may transfer the warranty for our products to your buyer,provided that the products remain in the place where they originally were installed. WHAT DOES THIS WARRANTY COVER? This limited warranty covers defects in materials and workmanship of the any SnapNrack photovoltaic solar mounting solutions(the "products")for the Warranty Period as defined below. In addition,products that have an anodized finish will be free from surface peeling, cracking or chalking of the finish provided that they are not exposed to abnormal atmospheric conditions. WHAT DOES THIS WARRANTY NOT COVER? This limited warranty does not cover any damage due to:(a)transportation;(b)storage;(c)improper use;(d)failure to follow the product installation manual or to perform any preventive maintenance;(e)modifications;(f)unauthorized repair;(g)normal wear and tear;or(h) external causes such as accidents,abuse or other actions or events beyond our reasonable control. WHAT IS THE PERIOD OF COVERAGE? This limited warranty starts on the date the products are installed at your location and lasts for 20 years for aluminum products and 10 years for all other products. The anodized finish warranty is five years. Each of these is a"Warranty Period".The applicable Warranty Period is not extended if we repair or replace the products.We may change the availability of this limited warranty at our discretion,but you will always be entitled to the warranty that was offered when you purchased the products. WHAT ARE YOUR REMEDIES UNDER THIS WARRANTY? With respect to any defective product during its Warranty Period,we will,in our sole discretion,either:(a)repair or replace such product(or the defective part)free of charge or(b)refund the purchase price of such product.We will also pay for shipping and handling fees to return the repaired or replacement product to you if we elect to repair or replace the defective product. HOW DO YOU OBTAIN WARRANTY SERVICE? To obtain warranty service,you must write to our address set forth above during the applicable Warranty Period. Please provide your name, address,phone,email and any other preferred means of contact. You will also need to provide some proof of purchase of our products,which may take the form of a work order from a solar installer that identifies the products and the date they were installed at your location.You will be asked to provide evidence that will allow us to conclude that we have breached our warranty. If we find such a breach,we will issue you a Return Material Authorization,if we elect to have you return the products to us. Snarack- Solar Mounting Solutions LIMITATION OF LIABILITY THE REMEDIES DESCRIBED ABOVE ARE YOUR SOLE AND EXCLUSIVE REMEDIES AND OUR ENTIRE LIABILITY FOR ANY BREACH OF THIS LIMITED WARRANTY.OUR LIABILITY SHALL UNDER NO CIRCUMSTANCES EXCEED THE ACTUAL AMOUNT PAID BY YOU FOR THE DEFECTIVE PRODUCTS. WE SHALL NOT UNDER ANY CIRCUMSTANCES BE LIABLE FOR ANY LOSS OF ELECTRICAL GENERATION FROM YOUR PHOTOVOLTAIC SYSTEM,THE COST OF UTILITY OR OTHERPOWER TO REPLACE LOST ELECTRICAL GENERATION,THE COSTS OF ANY REPAIRS TO OTHER COMPONENTS OF YOUR PHOTOVOLTAIC SYSTEM,THE ROOF OR THE BUILDING WHERE THE PRODUCTS ARE INSTALLED,OR ANY OTHER FORM OF CONSEQUENTIAL, INCIDENTAL,SPECIAL OR PUNITIVE DAMAGES OR LOSSES,WHETHER DIRECT OR INDIRECT. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES,SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. 877-732-2860 www.snapnrack.com contact@snapnrack.com s c 6 tiM �� �d SS XAI 3 oail sJu'� W p a OtIJL ►5 �u�us a xa � a a1�1 ply 1� • u u s r < Ao, 0ou a r00 sl M_ m WOO o[)ounins MAW 8t7pq-ttS-09£ _auotld T9986 VM 'aaA110OU A V e1S ' 1S PIIS 3 S06T ' "1`-•tet'.- ,_ .. :algellene osl b .8 F VIN aOuell T 7 C 9i 8 F WDl T dCO YOH T vuiLISU J - T aoslS Ir -T V 9T S SS 1108 'Ul -T _ :shed �luimojjoj auk ql!m alaidwoo awoo sji�j 11d T00-8900TH #I!H sjoou afflums aoj j!M ;ooj-7 ;unow z3 .apis -moll aalem -suoijean,'Jijuoa eldillnw aagl!a uo �uijunow Iiea laaaipaa o} pau!3isap �lulgsejj aoj aseq wnuiwnle ali}eSJ@A aoj smolle looj I pajeaaas r ;loos aMegs/a}isodwoo Aue aol algeanp pue ju�?!j aalem si walsAs �luijunow loos inp •uoilellelsui (sea aol pau,2isad purr paaaaui�u3 . . • ;unolu joom z3 SUNM*MCNIk' Limited Warranties D10013-V003 j 30-Jun-17 SunModo Corporation("SunModo")warrants the original buyer("buyer")at the bear all costs of shipment or transportation related to the repair or replacement original installation site("site")that any of the SunModo solar racking products of the nonconforming product.Such repair or replacement shall be Buyers sole ("product")manufactured by SunModo and properly installed,in accordancewith remedy and shall fulfill all of SunModo's obligations with respect to the product SunModo's Installation Instructions or used for the purpose for which the and all warranty claims.All claims made under this warranty must be submitted products are designed per SunModo requirements. Buyer may transfer this to SunModo in writing to the address below within 20 days after Purchaser's warranty to a subsequent site owner,or if original buyer is a contractor to the discovery the subject defect or problem or the warranty claim will be barred.A site owner,so long as the transferee agrees to this limited warranty terms as if formal document proving the purchase,the purchase date, and installation or it were the buyer. Proof of purchase is required for any warranty claim. delivery date of the product is required with any warranty claim. Warranty Period. The Warranty Period begins on the day the Products were Indemnification. Buyer shall defend,indemnify and hold harmless SunModo shipped from SunModo, or directly from SunModo's vendors, and remains in and its Related Persons(as defined below)(each,an"Indemnified Party"),with force for the period:a)Products installed on projects located 2 miles or greater counsel reasonably acceptable to the Indemnified Party,from and against any from salt or brackish bodies of water will be structurally-related manufacturing and all Claims (as defined below)which may be suffered or incurred by the defect warranted for 10 years,free of functionally-related manufacturing defect Indemnified Party or imposed or asserted against the Indemnified Party: (a) warranty for 20 years, and 5 years finish. b) Products installed on projects resulting from any cause on or about the premises where any Product is located less than 2 miles from salt or brackish bodies of water will be structurally- installed;(b)resulting from the use of the Product;(c)arising out of any actual related manufacturing defect warranted for 10 years,free of functionally-related or threatened damage to property, or injuries to or death of persons for any manufacturing defect warranty for 20 years,and 3 years finish. reason, including but not limited to, product performance or malfunction, negligence, or improper installation. "Claims"shall mean any and all claims, Structural Warranty. Products are warranted against structural failure due to actions,demands, proceedings,losses,damages,liabilities, losses,costs and cracking, buckling, bending, or tearing arising under normal use and expenses, including attorneys', investigators' and consulting fees, court costs environmental conditions,for the warranty period. and litigation expenses; "Related Person" shall mean any member, partner, principal,officer,director,shareholder,employee,agent,contractor,consultant, Finish Warranty. The Finish Warranty does not apply to: a) any foreign representative,affiliate,assign,successor-in-interest of a specified Party,or any residue deposited on the finish; b)surface oxidation, pitting, rust, peeling and other person that has obtained or hereafter obtains rights or interests from such chipping of components; c) products installed in corrosive atmospheric patty conditions,as defined solely by SunModo,included but not limited to exposure to corrosive chemicals,fumes,cement dust,salt water marine environments,or This Warranty constitutes the entire integrated agreement between SunModo to continual spraying of either salt or fresh water; d)mill finish products.The and Buyer concerning the Product Limited Warranties and supersedes all prior Finish Warranty is void if: a)the practices specified by AAMA 608&610-02- agreements and discussions and the terms or any purchaser orders, order "Cleaning and Maintenance for Architecturally Finish Aluminum" acknowledgements or similar documents. No agreement or understanding in (www.aamanet.org are not followed by buyer;b)if practices specified by ASTM any way purporting to modify this Limited Warranty, oral or written, shall be A780 1 A780M-09 "Standard Practice for Repair of Damaged and Uncoated binding on SunModo unless made in writing and signed by its authorized Areas of Hot-Dip Galvanized Coatings"are not followed by Buyer for SunModo's representative.The agents, employees, distributors, and dealers of SunModo galvanized steel-based components. The Limited Warranty is void if the product are not authorized to modify this Limited Warranty nor to make additional is not installed properly in accordance with SunModo's written installation warranties binding on SunModo. instructions,or is not used for the purpose for which it is designed,or the product has been modified,repaired,or reworked not authorized by SunModo. This Limited Warranty and the parties'rights herein are exclusively governed by and construed in accordance with the laws of the State of Washington, United The Limited Warranty does not cover the product that is damaged resulting from States of America,without regard to the laws of any other state or country.The shipping,storage,force majeure acts,and misuse or abuse during installation. State and federal courts located in Clark County, Washington shall be the removal,relocation or any other modification following the original installation,or exclusive venue for any legal action relating to this Warranty and Purchaser any use other than the original intended use, or damage caused by outside hereby agrees to the jurisdiction of such courts. forces(including,but not limited to acts of buyer)voids this Limited Warranty. The Limited Warranty covers the cost of parts manufactured by SunModo EXCEPT FOR THE LIMITED WARRANTY EXPRESSLY SET FORTH HE- Corporation only. Labor, installation, transportation and incidental costs REIN,SUNMODO MAKES NO REPRESENTATION OR WARRANTY OF ANY associated with warranty items are not covered by these warranties and are not KIND WHATSOEVER REGARDING THE PRODUCT AND DISCLAIMS ALL reimbursable.SunModo Limited Warranty only covers its products and under no OTHER WARRANTIES,EXPRESS OR IMPLIED,INCLUDING THE IMPLIED circumstances will be liable for indirect or consequential damages resulting from WARRANTIES OF MERCHANTABILITY,FITNESS FOR A PARTICULAR or related use by buyer of the product.Goods which may be sold by SunModo, PURPOSE,COURSE OF DEALING AND USAGE OF TRADE. but which are not designed or manufactured by SunModo are not warranted by SunModo,are sold only with the warranties,if any,of the original manufacturer IN NO EVENT SHALL SUNMODO BE LIABLE FOR,AND BUYER HEREBY thereof. AGREES TO INDEMNIFY SUNMODO FROM AND AGAINST,ANY AND ALL CLAIMS AND COSTS,INCLUDING ATTORNEY'S FEES,ARISING IN ANY Claim. If,within the warranty period,the product shall be proven at SunModo's WAY FROM THE SALE,USE OR INABILITY TO USE THE PRODUCT, sole discretion to be nonconforming, then SunModo shall repair or provide a BASED ON:LOSS OF USE,REVENUE OR PROFIT;DIRECT,INDIRECT, replacement for the nonconforming product,or any nonconforming part thereof, SPECIAL,PUNITIVE,LIQUIDATED,INCIDENTAL,CONSEQUENTIAL,OR at SunModo's option. Any such repair or replacement does not cause the ANY OTHER DAMAGE;OR INJURY TO PERSONS OR PROPERTY. beginning of new warranty terms,nor shall the warranty periods of this Limited Warranty be extended.SunModo's aggregate liability for all warranty claims shall not exceed the original purchase price of the nonconforming product.Buyer shall SunModo Corporation 14800 NE 65th Street,Vancouver,WA 98682 4 3 2 1 NOTES:UNLESS OTHERWISE SPECIFIED 1. DIMENSIONS SHOWN ARE INCHES[MILIMETERS]. 2. MATERAIL:AL 1060 T=1 mm. FINISH:CLEAR ANODIZED 10 Llm THICK. 4X RO.25 3. PART SHALL BE FREE OF OIL AND DIRT MARKS. 4. THE UNSPECIFIED INTERNAL RADII ARE.03". • 0.83 B 5. BREAK ALL SHARP EDGES AND BURRS. [21.01 B 6. THE UNSPECIFIED DIMENSIONS ARE SPECIFIED BY 2D CAD FILE. f. 0.11 A A o � [2.7] o v o cm 0.66 N s a. -� [21.7] 0.02 C [0.61 DETAIL C _ 1i o .---3.35 1.57 [85.0] [40.0] I R0.08 [2.0] -12.48 26.0° [317.01 1 _ 1 �' ~g ] o0 orn *� oo DETAIL B o O c; . A A SECTION A-A MATUMSEE NOTE Third Angle Prjx6on: Sunmodo Corp. GENERAL SPECIFICATIONS , -icmirt"di°°i'"i'ni°"1 1915 E 5TH STREET, STE C,VANCOUVER,WA 98661 x.xxx a.oI III 2d .l x.X%•0.0210.6Oem] Snrtal.n.rP.ddn TIRE U intoMlKi�ew.'"Ind ° :""' ROOF MOUNT FLASHING DRANK BY DATE ZCg 02/162011 DRAwNG NDMBER CHECKED BY B A20052-001 THIS DRAWING IS CONFIDENTIAL PROPERTY OF SUNMODO AND ITS CONTENTS MAY AppgpyALg NOT BE DISCLOSED WITHOUT THE PRIOR WRITTEN CONSENT OF SUNMODO CORP. SCALE: NONE SHEET 1 Of 1 4 3 2 1 1 DocuSign Envelope ID:B02D4593-1 BD9-4734-8484-BE000292B67C S u n B u g Solar' TURNKEY INSTALLATION AGREEMENT 9/17/2018 6:33:28 AM PDT THIS AGREEMENT,dated (the"Effective Date") is entered into between Ashley&Matthew Muspratt ("Owner") and SunBug Solar,LLC ("Installer") whose physical address is 1165R Mass Ave. Arlington MA 02476 and HIC License number is 163091, for the installation and/or improvement of a solar system at the Owner's premises located at 15 Franklin St Northampton,MA 01060(the"Premises"),all as more specifically described below(the"Project"). A. THE WORK Installer has previously submitted and Owner has approved the Proposal for the Project(the"Proposal"). By way of summary only,Installer's Scope of Work consists of the following elements as indicated: Materials Procurement Permitting Completion of Incentive Paperwork Turnkey Installation Electrical Interconnection Support Owner Operation Training Customer is responsible forproviding internet connection for online monitoring services B. CONTRACT DOCUMENTS. This Turnkey Installation Agreement together with the Terms & Conditions set forth below(the"Terms and Conditions"),any change orders executed by the parties("Change Orders")and the Proposal(each of which are incorporated herein by reference and may be referred to as the"Contract Documents") comprise the entire agreement of the parties and may be referred to as"this Agreement." C. CONTRACT SUM,PAYMENTS,REBATES. C 1. The cost of the Project, including all materials, labor and Installer's fees (described as the gross price in the Proposal) is$33,048 dollars ("Guaranteed Maximum Price"). The Guaranteed Maximum Price is a fixed price,not an estimate,and can only be changed by the parties executing and delivering a Change Order(see Section 10 of the Terms& Conditions for more information on Change Orders). However,the cost of the Project may be affected by unanticipated regulatory requirements (!U. ., such as wetlands studies) and unforeseen conditions occasionally discovered after Installer's engineering analysis (a., structural reinforcement or roof repair). If this is the case, a Change Order reflecting a new Guaranteed Maximum Price will be required in order for the Project to continue. C 2. Owner will make payments to Installer in accordance with the following schedule: Payment Terms Breakdown Amounts Down payment $1,000 $1,000.0 50%due on order of materials 50% $16,524.0 0%due on construction completion 40% $13,219.0 Balance due on Utility Interconnection Balance $2,305.0 otal $33,048.0 C 3. Installer is ordering materials on behalf of Customer and will warehouse materials until time of installation. C 4. Installer may bill Owner partial progress payments for construction work(eg.,when some work is scheduled to be done before or after our primary construction mobilization we may bill a portion of the construction payment for that work;rough-in electrical work,critter guard,etc.) C 5. Installer shall apply,on behalf of Owner,for applicable rebates including any rebates as offered by Owner's utility service. Unless otherwise noted below,any rebates shall be payable directly to Owner subject to utility or other third-party approval. Owner acknowledges that rebates payable to Installer have reduced the contract sum payable to Installer by Owner. ❑Rebates will be paid directly to Installer(Check only if rebates to installer). C 6. If requested by Owner, Installer shall submit a Massachusetts Department of Energy Resources (DOER) and Massachusetts Clean Energy Center(MassCEC) Mass Solar Loan Technical Application. In that case,this Agreement and subsequent work is contingent on Program Loan approval(the"CEC Loan Approvals"). C 7. Installer shall secure all necessary construction related permits, other permits and/or governmental licenses and inspections necessary for the completion of the Project. Unless otherwise noted, fees associated with acquiring such permits,licenses and inspections will be borne by Installer; owners who secure their own construction-related permits or deal with unregistered contractors shall be excluded from access to the Guarantee Fund. D. NOTICE OF RIGHT TO CANCEL. Owner may cancel this Agreement and the transactions contemplated hereby with no liability at any time prior to midnight on the third business day following the Effective Date. E. CONFLICTS. In the event of a conflict between this Turnkey Installation Agreement and any Contract Document or between the Terms and Conditions and any other Contract Document, this Turnkey Installation Agreement and the Terms and Conditions,respectively,shall govern. Page 1 of 6— SUNBUG SOLAR,LLC©2018 INSTALLATION AGREEMENT DocuSign Envelope ID:B02D4593-1 BD9-4734-8484-BE000292B67C w DO NOT SIGN THIS CONTRACT IF THERE ARE ANY BLANK SPACES Entered into as of the Effective Date: sw er SUNBUG SOLAR,LLC [signature] Ashley Muspratt By: By:Ben Mayer,Residential Sales Manager 9/17/2018 6:33:28 AM PDT Date: Solar Consultant Aaron Simms SUNBUG SOLAR,LLC o Sinned by: M.uspra#f [signature] By: Matthew Muspratt 9/17/2018 6:31:36 AM PDT Date: Page 2 of 6— SUNBUG SOLAR,LLC©2018 INSTALLATION AGREEMENT