Loading...
12C-019 (2) NORTH MAPLE ST-ARCANUM FIELD BP-2019-0517 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 12C-019 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: PLAY STRUCTURE BUILDING PERMIT Permit# BP-2019-0517 Proiect# JS-2019-000841 Est. Cost: $15750.00 Fee- $0.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: MOUNTAIN VIEW LANDSCAPES & LAWNCARE, INC_ Lot Size(sq.ft.): 369824.40 Owner: NORTHAMPTON CITY OF ARCANUM FIELD RECREATION DEPT Zoning:URA(100)/RI(97)/WSP(89) Applicant: NORTHAMPTON CITY OF ARCANUM FIELD RECREATION DEPT AT: NORTH MAPLE ST -ARCANUM FIELD Applicant Address: Phone: Insurance: 90 LOCUST ST NORTHAMPTON MAO 1060 ISSUED ON:10/30/2018 0:00:00 TO PERFORM THE FOLLOWING WORK.-PLAY STRUCTURE * NOTE - FOOTING HOLES AND FINAL INSPECTIONS REQUIRED POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: 2„-1: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 10/30/2018 0:00:00 $0.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner File#BP-2019-0517 APPLICANT/CONTACT PERSON NORTHAMPTON CITY OF ARCANUM FIELD RECREATION DEPT ADDRESS/PHONE 90 LOCUST ST NORTHAMPTON PROPERTY LOCATION NORTH MAPLE ST-ARCANUM FIELD MAP 12C PARCEL 019 001 ZONE URA(100)/RI(97)/WSP(89) THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Typeof Construction: PLAY STRUCTURE New Construction NOT- = FoO V*"(;z H01.4E5 Non Structural interior renovations EGTIo LA A6 Q Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO,RMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition Delay to Signature of Building OPficial Date T Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. f Versionl.7 Commercial Building Permit May 15, 2000 Department use only City of Northampton Status of Permit: Building Department Curb Cut/Driveway Permit - 212 Main Street Sewer/Septic Availability Room 100 Water/Well Availability Northampton, MA 01060 Two Sets of Structural Plans phone 413-587-1240 Fax 41 587-12-72 Plot/Site Plans °t Other Specify APPLICATION TO CONSTRUCT, REPAIR, RENOVATES CHANGE THE USE OR OCCUPANC OF,OR DEMOLISH ANY BUILDING OTHER THAN/ ONE OR TWO FAMILY DWELLJNG )n SECTION 1 -SITE INFORMATION 1.1 Property Address: r OF c 4 Tfi1. seg ion o be completed by office tioRTt' D�� tzoAo1e�2-r -t Awf Map It („)( Unit Prc.A�u M P�i°�`'1 P�l► Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Name(Print) Current Mailing Address: Signature Telephone 2.2 Authorized Agent: y Name(Print) <,- "tAa(/'1 Current Mailing Address: SCO 1 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building (a) Building Permit Fee 2. Electrical _ (b) Estimated Total Cost of _._.. Construction from 6 3. Plumbing Building Permit Fee . .. 4. Mechanical (HVAC) 5. Fire Protection 6. Total = (1 +2+ 3+4 + 5) Check Number This Section For Official Use Only Building Permit Number Date Issued Signature: Building Commissioner/Inspector of Buildings Date Versionl.7 Commercial Building Permit May 15,2000 SECTION 4-CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC FEET OF ENCLOSED SPACE Interior Alterations ❑ Existing Wall Signs ❑ Demolition❑ Repairs❑ Additions ❑ Accessory Building❑ Exterior Alteration ❑ Existing Ground Sign❑ New Signs❑ Roofing❑ Change of Use❑ Other ❑ Brief Description Enter a brief description here. IS"C PLLAT-1 0 111 Of Proposed Work: SECTION 5-USE GROUP AND CONSTRUCTION TYPE USE GROUP(Check as applicable) CONSTRUCTION TYPE A Assembly ❑ A-1 ❑ A-2 ❑ A-3 ❑ 1A ❑ A-4 ❑ A-5 ❑ 1B ❑ B Business ❑ 2A ❑ E Educational ❑ 2B I ❑ F Factory ❑ F-1 ❑ F-2 ❑ 2C ❑ H High Hazard ❑ 3A ❑ Institutional ❑ I-1 ❑ 1-2 ❑ 1-3 ❑ 3B ❑ M Mercantile ❑ 4 ❑ R Residential ❑ R-1 ❑ R-2 ❑ R-3 ❑ 5A ❑ S Storage ❑ S-1 ❑ S-2 ❑ 5B ❑ U Utility ❑ Specify: M Mixed Use ❑ Specify: S Special Use ❑ Specify: COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS, ADDITIONS AND/OR CHANGE IN USE Existing Use Group: _.. „., Proposed Use Group: _, Existing Hazard Index 780 CMR 34): Proposed Hazard Index 780 CMR 34): SECTION 6 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY Floor Area per Floor(so 1 St 1 5t �mm� 2nd _ £ 2nd �. rd 3 d 3 4 n ..._.__ �� 4m Total Area(so _ Total Proposed New Construction (so Total Height(ft) Total Height ft 7.Water Supply(M.G.L. c.40,§54) 7.1 Flood Zone_Information: 7.3 Sewage Disposal System: Public ❑ Private ❑ I Zone Outside Flood Zone❑ Municipal ❑ On site disposal system[] r' ' Versionl.7 Commercial Building Permit May 15,2000 8. NORTHAMPTON ZONING --] Existing Proposed Required by Zoning This co mn to be filled in by Buildi Department Lot Size i Frontage Setbacks Front —_, Side L: R: L:= R:°._.....................= Rear _.. Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved ! d _ arkin ) #of Parking Spaces - ~~ Fill: (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO /—X DON'T KNOW 0 YES 0 IF YES, date/issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DON'T KNOW 0 YES 0 IF YES: enter Book Page and/or Document#' B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained 0 , Date Issued: C. Do any signs exist on the property? YES 0 NO 0 IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES 0 NO 0 IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 NO 0 IF YES,then a Northampton Storm Water Management Permit from the DPW is required. Versionl.7 Commercial Building Permit May 15,2000 SECTION 9-PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES- FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116(CONTAINING MORE THAN 35,000 C.F. OF ENCLOSED SPACE) 9.1 Registered Architect: Not Applicable ❑ Name(Registrant): Registration Number Address 7 Expiration Date Signature Telephone 9.2 Registered Professional Engineer(s): Name Area of Responsibility i Address Registration Number i Signature Telephone Expiration Date Name Area of Responsibility i Address Registration Number r - Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number j Signature Telephone Expiration Date 9.3 General Contractor ...... Not Applicable ❑ Company Name: Responsible In Charge of Construction Address I Signature Telephone s Version 1.7 Commercial Building Permit May 15,2000 SECTION 10-STRUCTURAL PEER REVIEW(780 CMR 110.11) Independent Structural Engineering Structural Peer Review Required Yes 0 No 0 SECTION 11 -OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Print Name Signature of Owner/Agent Date SECTION 12-CONSTRUCTION SERVICES 10.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: License Number Address Expiration Date Signature Telephone SECTION 13-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes 0 No 0 f City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111 , S 150A. Address of the work: Y'6 06'm The debris will be transported by: P The debris will be received by: Building permit number: Name of Permit Applicant 'DtNb /0-- 7� /g Date Signature of Vermit Applicant f The Commonwealth of Massachusetts Department of Industrial Accidents I Congress Street,Suite 100 Boston,MA 02114-2017 '7M 5J8V`'e www mass.gov/dia Workers' Compensation Insurance Affidavit: General Businesses. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Business/Organization Name: (} � E-5-V [ANJ � ►�' � �4r^ G Address: b-1 pLo City/State/Zip: �L '�'/ � W Phone#: Are you an employer?Check the appropriate box: Business Type(required): 1.❑ I am a employer with employees(full and/ 5. ❑Retail or part-time).* 6. ❑Restaurant/Bar/Eating Establishment 2.❑ I am a sole proprietor or partnership and have no 7. ❑Office and/or Sales(incl.real estate, auto,etc.) employees working for me in any capacity. [No workers' comp.insurance required] g• ❑Non-profit 3.❑ We are a corporation and its officers have exercised 9. ❑Entertainment their right of exemption per c. 152, §1(4),and we have 10.❑Manufacturing no employees. [No workers' comp. insurance required]* 11.❑Health Care 4.❑ We are a non-profit organization,staffed by volunteers, with no employees. [No workers' comp.insurance req.] 12.0 Other *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. **If the corporate officers have exempted themselves,but the corporation has other employees,a workers'compensation policy is required and such an organization should check box#1. I am an employer that is providing 'wwoorkers`'compensation insurance for my employees. Below is the policy information. Insurance Company Name: / J� �yy Insurer's Address: City/State/Zip: �� �,1 �� flu Policy#or Self-ins.Lic.# 4-V T'-NA'Ech Expiration Date: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance covera verification. I do hereby certify, zed he in an pe es of perjury that the information provided above is true and correct Si nature: Date: Phone#: Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Licensing Board 5.Selectmen's Office 6.Other Contact Person: Phone#: www.mass.gov/dia Information and Instructions Massachusetts General Laws chapter 152 requires all employers to provide workers' compensation for their employees. Pursuant to this statute,an employee is defined as"...every person in the service of another under any contract of hire, express or implied,oral or written." An employer is defined as"an individual,partnership,association,corporation or other legal entity,or any two or more of the foregoing engaged in a joint enterprise,and including the legal representatives of a deceased employer,or the receiver or trustee of an individual,partnership,association or other legal entity,employing employees. However,the owner of a dwelling house having not more than three apartments and who resides therein,or the occupant of the dwelling house of another who employs persons to do maintenance,construction or repair work on such dwelling house or on the grounds or building appurtenant thereto shall not because of such employment be deemed to be an employer." MGL chapter 152,§25C(6)also states that"every state or local licensing agency shall withhold the issuance or renewal of a license or permit to operate a business or to construct buildings in the commonwealth for any applicant who has not produced acceptable evidence of compliance with the insurance coverage required." Additionally,MGL chapter 152,§25C(7)states"Neither the commonwealth nor any of its political subdivisions shall enter into any contract for the performance of public work until acceptable evidence of compliance with the insurance requirements of this chapter have been presented to'the contracting authority." Applicants Please fill out the workers'compensation affidavit completely,by checking the boxes that apply to your situation and,if necessary,supply your insurance company's name,address and phone number along with a certificate of insurance. Limited Liability Companies(LLC)or Limited Liability Partnerships(LLP)with no employees other than the members or partners,are not required to carry workers'compensation insurance. If an LLC or LLP does have employees,a policy is required.Be advised that this affidavit may be submitted to the Department of Industrial Accidents for confirmation of insurance coverage. Also be sure to sign and date the affidavit. The affidavit should be returned to the city or town that the application for the permit or license is being requested,not the Department of Industrial Accidents. Should you have any questions regarding the law or if you are required to obtain a workers'compensation policy,please call the Department at the number listed below. Self-insured companies should enter their self-insurance license number on the appropriate line. City or Town Officials Please be sure that the affidavit is complete and printed legibly. The Department has provided a space at the bottom of the affidavit for you to fill out in the event the Office of Investigations has to contact you regarding the applicant. Please be sure to fill in the permit/license number which will be used as a reference number.In addition,an applicant that must submit multiple permit/license applications in any given year,need only submit one affidavit indicating current policy information(if necessary). A copy of the affidavit that has been officially stamped or marked by the city or town may be provided to the applicant as proof that a valid affidavit is on file for future permits or licenses. A new affidavit must be filled out each year.Where a home owner or citizen is obtaining a license or permit not related to any business or commercial venture(i.e.a dog license or permit to burn leaves etc.)said person is NOT required to complete this affidavit. The Department's address,telephone and fax number: The Commonwealth of Massachusetts Department of Industrial Accidents 1 Congress Street Boston, MA 02114-2017 Tel. #617-727-4900 ext. 7406 or 1-877-MASSAFE Fax# 617-727-7749 www.mass.gov/dia Form Revised 02-23-15 C-fi -A:f -7 — 1Reeeive4 By City of Northampton AUG 29 018 Vendor Contract Cover Sheet City Au Jitor (To Accompany All City Contracts to City Auditor, Purchasing and Mayor's Office) 1. Department and/or Division Name: Parks & Recreation Department 2. Vendor Name: Mountain View Landscaping, Inc. 3. MUNIS Vendor I.D.#: 65435 Department Contract#(if any): 4. Source and Amount of Funds: Please Fill in Below Source: Account Name: Account Number: Amount: Total Per (Check all that Source: apply) ❑ Budget: ❑ Grant: ® Revolving: 53D Revolving 2401 630 5,013.40 ❑ Borrowing: ® Other: Capital Project Arcanum 19303 586716 10,736.60 Field Play Structure Total Amount 15,750.00 of Contract: 5. Period of Contract Coverage (If Applicable): August 1, 2018— December 21, 2018 6. Brief Description of Goods and/or Services being provided (e.g., Is this a part of a larger project, stand alone, or is it an amendment to a contract?): Installation of Arcanum Field Play Structure 7. Does the vendor have a Northampton Office? Yes X No (If local)Taxes owed? Yes X No 8. Please list time and dates that contracts were delivered: n Date Received Date Completed Originating Department Pam,4 Auditor, Joyce Karpinski: Ch. Proc. Off., Joe Cook: Finance Director, Susan Wright: Mayor David Narkewicz: CITY OF NORTHAMPTON MASSACHUSETTS CONTRACT FOR Arcanum Field Play Structure Installation THIS AGREEMENT, executed this - day of `� 2019 by and between Mountainview Landscapes and Lawncare. Inc. hereinafter caAed "Vendor" and the City of Northampton, a municipal corporation in the County of Hampshire, Commonwealth of Massachusetts, party of the second part hereinafter called "Owner". WITNESSETH, that for the consideration hereinafter mentioned, the Owner and the Vendor shall agree to the terms and conditions contained in this contract, enumerated as follows: The Owner-Vendor Agreement, Bidding Documents, Contract Forms, Specifications contained in attached and all addenda issued prior to and all Modifications issued after execution of the Contract. THE OWNER shall pay the Vendor for the performance of this contract in the sum of $15,750.00 dollars in accordance with the terms of this contract. This contract shall not be altered in any particular without the consent of all parties to this contract. All alterations to this contract must be in writing and authorized as such by the Mayor and a Majority vote of the Board, Agency, or Committee signing this contract. The Vendor shall not delegate,assign or transfer any of its duties delineated in the scope of services without prior written consent from the CITY. In the event the Vendor is a corporation a certificate that the person executing this contract is duly authorized to sign, must accompany this contract. Notwithstanding anything in the Contract documents to the contrary, any and all payments which the City is required to make under this Contract shall be subject to appropriation or other availability of funds as certified by the City Auditor. Obligations for payments beyond the current fiscal year are subject to appropriation and this Contract shall be canceled in the event of non-appropriation. Final payment on this contract shall release and discharge the Owner from any and all claims against the Owner on account of any work performed hereunder, or any alteration hereto. The Vendor shall indemnify and hold harmless,the CITY and all of its officers,agents, and employees against all suits,claims or liabilities of every nature,arising out of,or in consequence of,the acts or omissions of the Vendor, its employees, agents, or sub-contractors in connection with their rendering of services or goods under this AGREEMENT and will, at the Vendor's own cost and expense, defend any and all such suits and actions By signing this contract the Vendor agrees to subject any dispute to mediation, at the option of the City, prior to filing suit in any forum. This contract shall be deemed to be a Massachusetts contract and its interpretation and construction shall be governed by the laws of Massachusetts and the Charter and Ordinances of the Owner. The provisions of this contract are severable. If any provision of this contract shall be held unconstitutional by any court of competent jurisdiction, the decision of such court shall not affect any other provisions of this contract. The City of Northampton is not bound by this contract until approved by the Mayor of Northampton. Pursuant to M.G.L. Chapter 62C, Section 49A, I certify under the penalties of perjury that I have, to my best knowledge and belief,complied with the law of the Commonwealth relating to taxes,reporting of employees and contractors, and withholding and remitting child support. I further authorize the City of Northampton to deduct from the amounts due under this contract, any overdue taxes,real or personal, or any other fees due to the City of Northampton from the vendor which become due and payable by the vendor or its officers, directors or agents during the term of this contract or until the final amounts due under this contract are paid in full. The Contractor certifies that a) neither it nor any of its subcontractors have been subject to a federal or state criminal or civil judgment, administrative citation, final administrative determination, order or debarment resulting from a violation of G.L. c. 149,c. 151,or the Fair Labor Standards Act within three (3)years prior to the date of the Contract, or b) that if it or any of its subcontractors have been subject to a federal or state criminal or civil judgment, administrative citation, final administrative determination, order or debarment resulting from a violation of G.L. c. 149, c. 151, or the Fair Labor Standards Act within three (3) years prior to the date of the Contract, the Contractor has provided copies of any such judgment, citation, determination or order to the City prior to the date of the Contract and has procured a wage bond or insurance. The Contractor certifies that while the Contract is in effect, it will report any instance of the above to the City within five (5) days of Contractor's receipt. Check one: The vendor does €not€have a Northampton office. IN WITNESS WHEREOF the Owner caused these presents to be signed in quadruplicate and approved by David Narkewicz its Mayor and the said Vendor has caused these presents to be signed in quadruplicate and its official seal to be hereto affixed by its officer or agent thereunto duly authorized (by the attached corporate resolution). This instrument shall take effect as a sealed instrument. Vendor: MOUNTAIN VIEW LANDSCAPES AND LAWNCARE INC. Vendor t f'\ it's STEPHEN M.CORRIGAN Authorize g PRESIDENT 81812018 Title Date Please attach one W-9 to this contract when you return it to the City. Certificate by Corporation to Sign Contract STEPHEN M.CORRIGAN MOUNTAINVIEW LANDSCAPES AND LAWNCARE INC. I, Secretary of , hereby certify that at a (Name) (Name of Corporation) duly authorized meeting of the Board of Directors of the MOUNTAINVIEW LANDSCAPES AND LAWNCARE INC. (Name of Corporation) held on 2171218 at which all the Directors were present or waived notice, it was (Date) voted that, STEPHEN M.CORRIGAN PRESIDENT be and he hereby is authorized to execute contracts (Name) (Title) and bonds in the name and behalf of said corporation,and affix its Corporate Seal thereto,and such execution of any contract or obligation in this company's name on its behalf by such officer under seal of the company,shall be valid and binding upon this company, A TRUE COPY, ATTEST: STEPHEN M.CORRIGAN PRESIDENT (Secretary) Place of Business 67 OLD JAMES STREET CHICOPEE,MASSACHUSETTS 01020 Date of this Contract AUGUST 8,2018 City of Northampton,Massachusetts BID RECORD Subject of Procurement Arcanum Field Play Structure Installation Department Parks &Recreation Informal Quotes (under$50,000) Formal Bid _ If yes, dates advertisements appeared in the newspaper, Commbuys, City website, G&S Bulletin, Central Reg.(as required by the type and value of the procurement) Commbuys: Published 6/6/18 City Website: June 6 2018 Date of Bid Opening and Time June 20 2018 2:00pm Recorded By Ann-Marie Moggio Bidder Name Bidder Address Bid Price Comments 1. Mountainview 67 Old James Street, $15,750.00 Landscapes and Chicopee, MA 01020 Lawncare Inc. 2. 3. 4. 5. This list is a complete and accurate record of the bids or quotes received for the named supply or service. Signed under penalties of perjury. (Sign if purchase is over$50,000) Procurement Officer Witness CITY OF NORTHAMPTON: Date Northampton Parks & Recreation Director nizgDate Chief Prdb. Officer, approved as to form and c. 30B compliance Date City A ditor, approved as to appropriation. Date Mayor avid Narkewicz � O CERTIFICATE OF LIABILITY INSURANCE DAT8/9�ZO1HY ) ACORI? THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Rebecca Kubosiak The Dowd Agencies, LLC PHONE FAX 14 Bobala Road (A/C,No,Ext):413-437-101.11-9.... (A/C,No)413-437-1419 Holyoke MA 01040 ADDRESS: rkubosiak dowd.com PRODUCER MOUVI2 C.lISIQM.81D q; _._._.—._.... __ ........ _._._... ____.__...._ INSURER(S) AFFORDING COVERAGE__ NAICt INSURED INSURER A_West American Insurance Company 44393 ._ _..................__.._........._._......-i....._.._......------..___..._ ................_ _...__....................---...-.._........_'------------..._ Mountain es Landscapes& awncareInc INSURERS:American Fire&Casual Company 24066 67 Ofd James Street Chicopee MA 01020-2354 INSURER c__Ohio Casualty Insurance Company _ T 24074____ INSURER 0:AIM Mutual Insurance Company33758 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: 1572964834 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED.NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCEDBY PAID CLAIMS. - ILT R TYPE OF INSURANCE 'iADDL SUER: _ POLICY EFF POLICY EXP LIMITS LTR POLICY NUMBER MM/DDIYYYY MMIDDIYYYY A GENERAL LIABILITY BKW58244625 1/1/2018 111;2019 EACH OCCURRENCE $1.000 000DAMATE-TURENTE _ X COMMERCIAL GENERAL LIABILITY PREMISES Ea occu encei $300,000 `—,--I CLAIMS-MADE n OCCUR 1 .MED EXP(Any,one person) $15,000 PERSONAL&ADV INJURY :$1.000.000 !;.�y..__..._...._.........___.._._._..____-.........__.._.__.....___._.............._. GENERAL AGGREGATE....__.....__.. : .2000,000..__.__................ GEN'L AGGREGATE LIMIT APPLIES PER: I PRODUCTS-COMP/OP AGG ,$2.000.000 POLICY X PRo- X i LOC $ B AUTOMOBILE LIABILITY BAA58244625 1112018 ':. 1/10019 COMBINED SINGLE LIMIT $1.000.00c - (Ea accident) _!ANY AUTO BODILY INJURY(Per person) $ _X ALL OWNED AUTOS i BODILY INJURY(Per accident);$ X SCHEDULEDAUTOS !, i -----, PROPERTY DAMAGE $ X HIRED AUTOS (Per accident) __....---------- ._.... _X NON-OWNED AUTOS $ I$ C X ;UMBRELLA LIAB X OCCUR US058244625 1/1/2018 i 1/112019 EACH OCCURRENCE 1$10,000,000 EXCESS LIAB CLAIMS-MADE i j AGGREGATE $10,000,000 DEDUCTIBLE X RETENTION $10 onn $ D WORKERS COMPENSATION WMZ800800523? 1202018 1120/2019 X WC STATU- OTH-',. AND EMPLOYERS'LIABILITY RY LIMITS ANY PROPRIETOR/PARTNER/EXECUTIVE Y/N i _E.L.EACH ACCIDENT $1,000 000 OFFICER/M EMBER EXCLUDED? a N/A ..... ..__...__. _._....___ ..._.. (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE:$1.000.000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT`:$1 000 non A Herbicide/Pesticide 'BKW58244625 1/112018 1/12019 1,000.00O 2.000:000 DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (Attach ACORD 101,Additional Remarks Schedule,if more space is required) Re:Beauregard&Schiavina Memorial Park.Project Number 18-021. Certificate Holder is named as Additional Insured per written contract in regard to general liability only. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,THE ISSUING INSURER WILL ENDEAVOR TO MAIL 30 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT,BUT FAILURE TO DO SO SHALL IMPOSE Northampton Recreation Department NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER,ITS 100A Bridge Road AUTHORIZED REPRESENTATIVE Florence MA 01062 r I ©1988-2009 ACORD CORPORATION. All rights reserved. ACORD 25(2009109) The ACORD name and logo are registered marks of ACORD F OmwWton City of 4 Louis Hasbrouck<Ihasbrouck@northamptonma.gov> .............................................. ........... _.....__.. Arcanum Field play structure Louis Hasbrouck<Ihasbrouck@northamptonma.gov> Mon, Oct 29,2018 at 4:21 PM Draft To: stevec@mountainviewinc.com Cc:Ann-Marie Moggio<amoggio@northamptonma.gov> Steve, We've approved the permit for Arcanum Field.We'll want to do 2 inspections; one when the footing holes are dug, before cement and a second when you're finished. I'm assuming the footings are sized per the sheet you submitted (attached) Louis Hasbrouck Building Commissioner City of Northampton Town of Williamsburg (413)587-1240 office (413)587-1272 fax . Arcanum Play.pdf 425K r Tris Pry OgL*mm a Tout May Cur'npeneMs 12 �Sl PW Peykl and Cen"ry "lem"ItdRd for �° �pWy&park R.4ara poi cwgww a 7 ve«cswcax ' Street mw~� SaMt VV-i-0" OMIC7 int t 4L 4u5athhemptonMAO7D60 S 1� T� sent tlnaudPwy�A&aseRMbyRupp 0 Raq. 0 1335 agw only when 19 0612W17 EbvoW C 4mnsnb Aecosmbis by Trandu 7 R", 4 Cn7g1 f�tl>imtYM M k*mm Am Rn~ An t f x Ir bill Qum%NunEsr: 401 Ch"low et,me,sw ACC" +around lswi Caanpomnr 6h~ 2 Rey. 2 Sd' New Erglaid Retxeam� 26'-8"x 2S-11' 642-108618 ch.sm f—o wwP p�y R�� eoo•Tzt.tmr r ww«porywwprrccaa tailhrcM Types of Oroond Level CompaneMe 2 Roy. 2 6)MRA Order 7339611 FOOTINGS ORDINATE TABLE HOLE X Y DIAD 1 -1'-8 1/2* -4'-6" 4'-10" Y 2 -1 -3" --2'-31/2* 2'-7 1 2" 7t;t 12 w7i 20 23 3 -1'-3 -0'-8 1/2" 1'-5 6 fB 4 0'-0" -6"-0" 6'-0" 1 ('�� 5 0-0 -3-0" 3'-0' 3 g 1 1 A \.n/ 6 0'-0" 0"-1 0'-0" 2 A 24 7 1'-8 i'--7 1 2 2'-2 1/2" ® A 10 A� 1$ B 18 8 1,-G" -11'-5 il'-6" 9 3-0" -6'10 6_g 1 2 1/ 22f.1 1O 3-0 -3,-0, 4'-3 �� 1�,.�.J/ 11 T-0" 0'-0" 3'-0" 4 9 15(„'� 712 Y-e 13 4'-6" -7'® 53 8 2 7 1 2" 810" 138 14 5-4 0-5 5'-4 25 K 15 6'-0 -6'-0 6'-6 16 6'-Y -3-0 6'-8 1/2" 17 8'-0" 0'-0" 6--0" 26 18 7'-0 1 2" -2-7 112.* 7'-6" 19 7'-0 142' -0'-4 142- 7'-0 112" 20 7'-5' 0'--10 7'-6- FOOTINGS TABLE 21 8'-3 -1'-3 13'-4 1 2TYPE DIAMETER SIDE DEPTH CITY. 22 8'-7 -4'-8" 9'-8 1/2 A V-6' 45.72cm 2'-6 76.20cm 11 23 1 9'-8 1/2 0'-10 91-g. P �'-? .3.5 mit ss+ 3-6 .7fi2M 1I £t M1i P P `£" -v^'-3 r/2'" J 1'-0fiO�48cm 2'-0"�7620,- m 1 25 10-8 -9-0 1 2" 14'-0!K 3-04crn 2'-8m 1 26 10'-9" 11'-3" 15'-6 1/2 1 n u rr rtwrsietVinre apMion tlKt em satKarn.etawn neTs�,avn�es wu wmnt eds w,rrure.tcxcanaHq sxamstb9+ry!uted.nn proper eccoM}t+r.r,ns�rnq snet bOsMsr vvelhh odwr naaasry yrard rows pry UR�C7RTAW:Nevw MNeq PMN Ktutpment Over Nfd,unrem/term su oc"much so owso.Coromele,w.&-roatud MOfi.h Is ow o"oes mvpmwtk:"to wtv"W"-TiNltynl*me tewow omv*r4 4n epprap an wrwum of ma*m tt"WAM b dM1"#006W w • NRD BID FORM To the Awarding Authority: A. The undersigned proposes to furnish all labor for the Assembly and Installation of Arcanum Field Play Structure in accordance with the accompanying plans and specifications as shown on bid for the contract price specified below, subject to additions and deductions according to the terms of the specifications. B. LUMP SUM BID For all work in the Contract: ev $ 54 7S r In Numbers trot4A- Aa V&vt9n/ #VA1ZIWSZ 1e%A"--7y� In Words C. Estimated Installation/Completion Date: T• �v • �. D. The undersigned agrees that, if they are selected as general contractor,they will within five days,Saturdays, Sundays and legal holidays excluded, after presentation thereof by the awarding authority, execute a contract in accordance with the terms of this bid and furnish a performance bond and also a labor and materials or payment bond, each of a surety company qualified to do business under the laws of the Commonwealth and satisfactory to the awarding authority and each in the sum of the contract price, the premium for which shall be paid by the general contractor and are included in the contract price. The undersigned herby certifies that he is able to furnish labor that can work in harmony with all other elements of labor employed or to be employed on the work and that they will comply fully with all laws and regulations applicable to awards made subject to Section 44A. The undersigned hereby certifies that he is able to furnish labor that can work in harmony with all other elements of labor employed or to be employed on the work; that all employees to be employed at the worksite will have successfully completed a course in construction safety and health approved by the United States Occupational Safety and Health Administration that is at least 10 hours in duration at the time the employee begins work and who shall furnish documentation of successful completion-of said course with the first certified payroll report for each employee; and that he will comply fully with all laws and regulations applicable to awards made subject to section 44A. Page 3 of 4 Northampton Parks & Recreation - 413.587.1040 recreation@northamptonma.gov ..N1 VVUH MNRD The undersigned further certifies under the penalties of perjury that this bid is in all respects bona fide,fair and made without collusion or fraud with any other person.As used in the subsection the work "person" shall mean any natural person,joint venture, partnership, corporation or other business or legal entity. The undersigned further certifies under penalties of perjury that the said undersigned is not presently debarred from doing public construction work in the Commonwealth under the provisions of Chapter 29,Section 29F, or any other applicable debarment provisions of any other chapter of the General Laws or any rule or regulation promulgated thereunder. Pursuant to M.G.L Ch. 62C, sec.49A, I certify under the penalties of perjury that I, to my best knowledge and belief, have filed all state tax returns and paid all state taxes required under law. E: References: SEE ATTACHED Date: JUNE 20,2018 MOUNTAINVIEW LANDSCAPES AND LAWNCARE INC. NAME OF GENERAL BIDDER SIGNATUR PERSON SIGNING T!-_ E-STEPHEN M.CORRIGAN PRESIDENT 67 OLD JAMES STREET BUSINESS ADDRESS CHICOPEE,MASSACHUSETTS 01020 CITY AND STATE 413-536-7555 X109 PHONE STEVEC@MOUNTAINVIEWINC.COM EMAIL Page 4 of 4 Northampton Parks& Recreation 413.587.1040 recreation@northamptonma.gov Genera! contract submission confirmation Th.e follQwinq General Cot act su na1ss on as success u y receive . publishJanned date of is v, AWir�din' A ency +oven, Name and Northamntoel_Rec. Dept. 100A Dridge Rd. Florence MA 01062 ddress: Project Number: NA Estimated Cost: 3 Contractor a QualiFlcation: Qequired for DCAMH contracts over$130fJC%Highway DNlcla: ►�ts.ari q,000a AQc > �9olfea{ci �1�•l saiption belay, j Contact Information �;- Name: Anannarie Mogato � Phone: 2 - as 11 Fa vA Email Address: amoggioOnArthamjtol2m .aov .gotify ernaff address listed when ftnal publish datRAMWBEi Contract Information Project: Arcanum Field t s m Plans/Specifications A Bridge Rd. Florenced 20 Available: a.rn_ P o[e,cla!e anc Ilnw (+RnPrRI Rid Qt,/2n/,>m R I Tlrna 2:50 n.m. tM... .ly��y.: .r .�.r!rr•• �!* .tir Sys �!•• ►�?'•..R• t.i 1' �1. yM =� A 1�. iii City of Northampton Paye 1 of 1 Bid Opening pate:06120/2018 02 00 PM Printed:05/30/2018 12 38 PM BID SOLICITATION Bid Number 13D-1 8-1160-116OC-1 160L- 27901 D-18-1160-116OC-1160L- 27901 Description:Assemble and install play Alternate ID structure Requisition Number Item Cless-Item Ouan6ty Unit Und Price Total 1 Assemble and Install a play structure at Arcanum Field In Florence MA. 1 EA /,S,7M_ Contact Ann-Merle Moggio at amogy�northamptonma.gov for tAd �—�i TOTAL: •r� '�, THIS IS NOT AN ORDER,AND DOES NOT COMMIT THE PURCHASING ENTITY TO PURCHASE ANY GOODS OR SERVICES /�O!/N1, M VleKl Lam/✓ � PURCHASED O! 6,T BY: Jae Cook O,O ZO Phone#: (413)587-1246 Email:jcook®rwftmptonmagov BUYER structures n P�p•YCOr-2E cw„ps�,r Information0 NERS MANUAL Warranty includes:This docLument Hardware Listing Assembly . • Installation Instrucftions �. } �' �' 1; }` }: 1 E ' ,. M i i i play&park stru A RLAYCo*;tE company Dear Play & Park Customer, Thank you for choosing to purchase and install a Play & Park Structures play system. We appreciate the confidence and trust you have placed in our company. Your Play & Park Structures Installation Guide is enclosed. We designed this manual specifically for the products you have purchased. Included in this manual you will find the following documents: • Product Installation Instructions • 2-D Top View Drawing specific to your structure • Ground Plan If you have any questions concerning your new equipment, you can reach your recreation consultant by calling 1-800-727-1907. To contact a Play & Park Structures customer service representative, you may call 1-888-404-5737 or reach them online by sending an email to: customerservice0playandpark.com For more information on Play & Park Structures products, please do not hesitate to call us, or visit us online at www.playandpark.com. Thank you for your business; we look forward to working with you on future playground equipment projects! Sincerely, Play & Park Structures m. , ���. _ �- .. a �_ `_ .� .. ,.r�� .•..a� i �• t i I i, A � � 1 f 4 ' f i I i 1 y� - 1 { M �`, �;, I i ►: .. Safety Guidelines Maintaining your playground equipment as well as its surrounding area is essential to minimizing the risk of injury to users as well as maximizing its useful lifespan. Play& Park Structures STRONGLY recom- mends that you follow these Safety Guidelines in conjunction with conducting periodic maintenance inspections using the accompanying Playground Maintenance Checklist. When installing,always consider local conditions and codes. Good common sense works hand-in-hand with the instructions. LOCATING YOUR PLAY STRUCTURE Comply with the following when choosing the location for your new equipment: • Equipment should be placed to eliminate conflicting traffic patterns. As a general rule,allow at least 6'of free space around the entire structure,EXCEPT for slide exits, which require a distance X equal to highest point of sliding surface with a minimum of 72"and maximum of 96"from the edge of the slide. Example: a Slide from a 6' high deck requires 6'of clear space with resilient surfacing in front of and behind them for safe circulation. Example:a Swing with a 8' high beam requires 16' of free space in front, and another 16' behind it,for a total of 32. These minimum areas should be filled with the appropriate resilient surface material. See below for resilient surfacing recommenda- tions. • If your equipment includes any metal slides,they should be positioned in a shaded area, or at least positioned to avoid the sun's direct rays. • Never overlap the safety zones of adjacent equipment. All separate play equipment must have its own safety zone,and these cannot overlap. So,if you have an existing structure with a slide exit oriented toward your new one,add your minimum safety zone to that of the existing slide to deter- mine how far away you need to be. • Never install playground equipment near, around,or in conjunction with swimming pools, ponds, lakes or any other bodies of water. CHOOSINQ RESILIENT SURFACING MATERIAL Playground equipment must be installed on a soft, resilient,energy-absorbing ground surface. NEVER INSTALL PLAY EQUIPMENT ON CONCRETE,ASPHALT,OR GRASS. A fall on a hard surface from even a low platform of 3' high can result-in serious injury to the user. Refer to CPSC and ASTM F1292 for recommended surfacing depths and requirements. Tip: If your surfacing material is of the loose variety, checking for proper depth overtime can be made easy by applying a non-removable florescent tape or paint in a bright color at the proper level on each post. Thereafter,as the resilient surfacing material compacts or washes away,the person responsible for regular maintenance inspections can easily see it must be replenished as the marks become visible. Play&Park Structures•544 Chestnut Street•Chattanooga,TN 37402•SM.727.1907•ptayandpark.com-customerservice*0ayandpa&com 1 I i AFTER THE EQUIPMENT IS IN USE i • Never add components not intended for use with this product. • Never install other play equipment,fencing, landscaping,etc.,which encroach upon the safety zones of this equipment. • Check to make sure that there are no overhead obstructions within the use zone of the playground equipment that are not part of the play structures(example:tree limbs). Any overhead obstructions should be at least 84"above each platform or designated play surface or 84"above the pivot point of swings. All overhead utility line clearances above the use zone area should comply with all local,state and national codes. • Regularly inspect and maintain your playground equipment and its surrounding area. Proper maintenance of Play&Park Structures equipment includes using the accompanying Playground Maintenance Checklist to identify areas requiring repairs or replacement, and barricading the equipment to prevent use while corrections are being made. • If your playground equipment includes any wood components, bolts may need to be re-tightened after initial use due to wood shrinkage. Check and re-tighten all fasteners after the first few days of use,and again after the first 3 weeks of use. Thereafter,exercise normal maintenance procedures. Using a thread-locking compound on the threads of bolts can help prevent persistent loosening. • 'S' hooks must be completely closed. Replace all worn'S' hooks,and never re-use 'S' hooks. • Pipes should never be allowed to turn. In the case of wood playground equipment, make sure all collars are snugly flush against the inside of posts with set screws tightened and wood screws flush against the outside of the collar, and all flat head bolts and set screws are tight. In the case of steel playground equipment,check set screws for tightness. For specific information regarding playground safety and your responsibilities as the owner of this equipment, please contact the Consumer Product Safety Commission(CPSC),Washington, DC,for the latest guidelines for your play area and this equipment. If any conditions or damages are discovered in violation of these Safety Guidelines orthe accompanying Playground Maintenance Checklist,the play equipment should be barricaded immediately and children should not be allowed to use it until the conditions are corrected. 2 Play&Park Structures•544 Chestnut Street•Chattanooga,TN 37402•800.727.1407•piayandpark.com•customerservice*playandpark.com Introduction to Installation Instructions Revised 03.29.16 IMPORTANT! Please read the entire Installation Instructions packet before beginning the installation. Play& Park Structures has designed the SuperMax, DuraMax,totmax, Skyline, Boulderscapes and Horizons Play Systems to take advantage of all Consumer Product Safety Commission (CPSC) Guidelines and ASTM standards in force at the time of purchase in an effort to help reduce the chance of playground accidents. However,because studies have shown most playground injuries result from accidental falls,you, as the new owner of this equipment,are responsible for providing and adequately maintaining resilient playsurfacing under and around all playground equipment. Please refer to the accompanying Safety Guidelines as well as CPSC guidelines and this document for examples of such surfacing. We would like to provide the following suggested guidelines for your play environment: • Refer to the Footing Diagram and note the Minimum Area Required shown for this structure. This area must be filled with adequate resilient play surface material,and must be clear of all obstacles, including but not limited to trees, curbing, sidewalk,fence, other play equipment, rocks and landscaping,etc. • Acceptable play surfaces include sand,wood mulch, fine gravel or ground belt-less tires, if installed at the appropriate depths per CPSC guidelines for play surfacing. • When using sand, wood mulch, or ground belt-less tires,a minimum of 6" depth is recommended by the CPSC. Play& Park Structures recommends an additional 4".for a total of 10".to combat the fast compacting characteristics of these materials. Surfaces must be checked at least weekly for compacting,which reduces resiliency significantly. • Paved surfaces such as asphalt,concrete,gravel or sod are not acceptable for use under playground equipment, or anywhere within the stated Minimum Area Required. • Close supervision of children playing on or around the structure is strongly recommended, along with classroom and/or home instructions on acceptable behavior on the playground equipment. The full supervision of playgrounds Is the responsibility of the owner once the play structure has been properly installed. TOOLS REQUIRED: Play& Park Structures supplies the special bits required to fasten the"tamper-resistant"bolts. You will need common tools such as wrenches,Allen key set,drill, string line, level, mallet,shovels,post hole digger, pry bar,washable felt tip marker and a tape measure. Play&Park Structures-544 Chestnut Strout•Chattanooga.TN 37402•800.727.1907-playandpark.com-customerserviceOplayandpark.com 3 INSTALLATION GUIDELINES: 1. Compare all parts received to the packaging list. Notify Play& Park Structures immediately of any missing parts. We are not responsible for parts discovered missing over is days after receipt of the shipment. 2. Refer to your Footing Diagram to ensure this structure will fit into your actual site area. Note the Minimum Area Required measurements to determine clear space required.A minimum of 6'clearance is required between any obstacles and your structure. EXCEPT for slide exits,which require a distance X equal to the highest point of sliding surface with a minimum of 6'and a maximum of 8'from the edge of the slide(example:A slide from a 6' high deck requires 6' of clear space with resilient surfacing in front of its exit). 3. Site selection should include considerations of what is a safe and appropriate play area: a. A level and clear site is ideal,free of power lines or electrical equipment. b. Do not install play equipment near any bodies of water. c. If adjacent to a street with traffic,ensure adequate fencing acts as a barrier to children running into danger. 4. Site layout should include accurate measurement and marking of all footings prior to any installation. Use the dimensions shown between footings on the Footing Diagram to plot out the actual footprint of the play structure before doing any digging. Also, locate any free-standing play equipment in the same way, providing the necessary clearance between the equipment as well as any fences,trees,etc. Ensure at this time that you have enough total space fpr the equipment to be installed. S. Excavate holes as shown in the Footing Diagram using a string line. An optional string line level is very helpful. If a level and clear site is not possible,adjust the depth of the footings to maintain a minimum depth of 18 in.for support posts at the lowest grade. NOTE: if soil conditions are very loose or otherwise unstable,a larger diameter footing may be required. Consult with local contractors for appropriate recommendations. 6. Begin your SuperMax, DuraMax,totMax,Skyline, Horizons,and BoulderScapes Play Systems installation by erecting the decks as shown within the following instructions. IMPORTANT:Do not concrete product until instaillation is completel Once all decks are Installed,components such as slides,climbers, etc.,can be connected per their respective assembly instructions. Note that connecting components between decks such as Horizontal Ladders,Crawl Tunnels,Trapeze Beams,etc.,should be Installed concurrently with the decks to ensure they meet accurately. 7. CPSC guidelines mandate that there should be no gaps present in the playground equipment which fall between 3 Y:"and 9 .The positioning of certain components by the installer can affect this criteria,so you should always measure distances created when attaching components by the Installer,which can cause entrapment of a child using the equipment. Also,ASTM requires that no more than 2 threads of bolt can protrude from the nut. Any excess threads should be filed down and made smooth to the touch. 4 Play&Park Structures•544 Chestnut Street•Chattanooga,TN 37402•800.727.1407•playandpark.com•custornerservice0playandpark.com 8. When concrete is poured, be sure to keep the top 4" below the grade,and sloped away from the post to promote good water drainage. Wash off any concrete,which may have splashed onto the post before it dries. Allow all concrete to harden a minimum of 48 hours before using equipment. SAFETY DURING INSTALLATION: 1. Before doing any excavation, inquire about any existing underground utilities. 2. Do not leave the job site unattended without making sure that all fastening hardware on all equipment are tightened and all Drive Rivets are in place to prevent clamps from moving, in case of unauthorized use. PLAY& PARK STRUCTURES CLAMPS ARE NOT DESIGNED TO SUPPORT HUMAN WEIGHT WITHOUT THE DRIVE RIVETS INSTALLED,AND SUCH USE COULD CAUSE INJURY TO THE USER AND/OR DAMAGE TO THE EQUIPMENT. it is also strongly recommended that all installation areas be roped off with clearly marked warning signs posted. Any open footings should be covered with plywood or other suitable material. Even during installation,it has been found that children will use the unattended equipment,thereby risking accidents. 3. The installation area should remain roped off for at least 48 hours after the last concrete footer is poured. Children should not be allowed to use the equipment during this period so that concrete has a chance to fully set. 4. Do not attach swing chains,trapeze rings or similar moving components until after all construction is complete and resilient surfacing material has been installed. Remember that any equipment, which appearsto be complete and functional will invite unauthorized use regardless of its actual state of readiness. Finally, if you should have any questions regarding the proper installation of this equipment, please contact Play&Park Structures at: S44 Chestnut Street,Chattanooga,TN 37402 TOLL Free:800.727.1907 FAX:423.425.3172 EMAIL:customerservice@playandpark.com Visit our website: www.playandpark.com Play lk Park Structures•544 Chestnut Street•Chattanooga,TN 37402•806.727.1907•playandpa&com•custom erserviceOplayandpark.com S pIa & ark 60855 SURFACE MOUNT structures INSTALLATION INSTRUCTIONS FOR PARK STRUCTURES ISSUED/REVISED: 08WIl 4 NOTE 2`,8",10'LENGTH INDICATES THE SURFACING DEPTH.ALL COMPONENTS ARE SHIPPED AS STANDARD 30'INGROUND LENGTH.(20'DEEP HOLES&10' SURFACING) UPRIGHT CHART t SURFACING MATERIAL TO BE REMOVED DRILL Irr COMPONENT DEPTH WIOUT EXT. WIV EXT. DIAMETER 2' 2811/16' 2211116' HOLE THRU 8' 22 11116' 1611116' PIPE AND olz DRILL 112' 10" 20 11116' 14111111+' BASEPLATE DIAMETER HOLE NOTES: SOCKET THRU PIPE AND 1.DIM A"=MATERUIL TO BE BASEPLATE SOCKET REMOVED. DIM'A'=MAT.Td 2.SOME INGROUND COMPONENTS BE REMOVED ��• REQUIRE EXTENSIONS.REVIEW YOUR q• STANDARD INSTALLATION SHEIET IF EXTENSIONS ARE REQUIRED.ADJUST MATERIAL TO 8E MATERIAL TO BE REMOVED REMOVED ACCORDINGLY. Le.A COMPONENT REQUIRING 6' IMPORTANT:CHECK ALL GROUND EXTENSIONS,AND IF SURFACING DEPTH MEMBER LOCATIONS TO COMPENSATE IS TO BE 2",MATERIAL TO BE REMOVED FOR SLOPE BEFORE CUTTING( DETAIL 1 WILL BE 22 11116' (FOR SURFACE MOUNT INSTALLATIONS) DRILL 112"DIAMETER HOLE THRU BOTH COMPONENT/ COMPONENT ANDIOR UPRIGHT PIPE AND UPRIGHT SOCKET ON BASEPLATE 314'FROM END OF PIPE (NOTE:PIPE SHOULD BE FULLY SEATED AGAINST SHOULDER OF BASEPLATE SOCKET BEFORE DRILLING.) PROTECTIVE 318"TEE-NUT(PEEN SURFACING TEE-NUT AROUND j PIPE AFTER ASSEMBLY) _� J l 318"LOCKWASHER CHART 2 NUMBER O.D. ;BASE PLATE ` 404765 1.029' 404764 60M 15116•! 152850 80856 1518' 15285t &W SUTTON HEAD 60857 1 71W 152852 60858 2 3V 152853 SCREW 80859 2 7B' 152854 CONCRETE8W 60860 3112'}' 15_2_ SURFACE BASE PLATE 60861 5' { 152855 ((a'MIN.) r�1L.2 (SEE CHART 2) THICKNESS (SURFACE MOUNT PLATES) 6 Play&Park Structures-544 Chestnut Street-Chattanooga.TN 37402-800.727.1407- playandpark com-customerservice0playandpark.com CUT THROUGH CORED PRE-EXISTING HOLE 4"MINIMUM CONCRETE SLAB CONCRETE SLAB "44STANDARD HOLE , DEPTH IN-GROUND PER COMPONENT -4 GRAVEL I CRUSHED (SEE INSTALLATION SHEET) EARTH STANDARD HOLE DIA.PER COMPONENT (SEE INSTALLATION SHEET) DETAIL 4 EXISTING SLAB PILING FORM (POUR AROUND FORM) 'PILING FORM IS USED TO 'REMOVE FORM AND POUR CREATE VOID DURING FOOTING AFTER 4"MINIMUM INITIAL POUR. SLAB IS CURED AND r CONCRETE SLAB EQUIPMENT IS INSTALLED TI STANDARD HOLE DEPTH IN-GROUND GRAVEL!CRUSHED PER COMPONENT (SEE INSTALLATION SHEET) EARTH STANDARD HOLE DIA.PER COMPONENT DETAIL S (SEE INSTALLATION SHEET) NEW SLAB PAGE 3 Play&Park Structures•544 Chestnut Street•Chattanooga.TN 37402-600.727.1407•playandpa&com•customerservice0playancipark.com 7 SURFACE MOUNT INSTALLATION INSTRUCTIONS 1.Bafore assembling this equipment,read the enclosed INSTALLATION INSTRUCTIONS In the installation booklet;follow all the during installation. 2.Concrete requirements for Sufaca Mount shall be 4'minimum thickness wt 3000 psi. 3.For Surface Mount remove required length of component and/or upright as Indicated In DETAIL 1.See CHART 1 for the material length to be removed.(RequhW for 2',t3'or 10'surbtce mount only.)Note.Debur and remove any sharp edges on part after cut Is made. 4.Drill 1I diameter hole thru componenVuptights and baseptate socket 314'from end of pipe.The pipe should be fully seabed against neck of socket before drilling holes. 5.Attach Component to base plate as shown In MAIL 2.See CHART 2 for the specific base plate required for the diameter pipe being used.(Required for 2',8'or 12'Surface mount only.) IMPORTANT.Some components such as slides,chinning ban;,nets,dimers,etc.may require*cored*stoles to help eliminate movement when Installed.Refer to Ground Plan configuration to determine If'cored"holes are required. NOTE.,if concrete slab Is pre-existing and a cored hole is required it must be drilled through wdsltng concrete to allow for concrete footing.Review your standard installation sheet for correct size and location of cored hole.See DOW 3. NOTE.Coned holes can be created pdorto concrete pour by using piling tams to create a void when pouring.See Detail 4. NOTE.If a base plate Interferes with an Insert required for a below deck component that Esse plata will require a.wW to be applied In the field. -CONCRETE SPECIFICATIONS 1.Depth of concrete must be 4'minimum with wire mesh reinforcement 2.Base shall be 3"crusted rock over compacted subgrade. 3.Minimum 7 days cure-full cure altar 28 days. 4.Concrete rating shell be 3,000 PSI(minimum),28 days 3,5W PSI. COMPONENT OR UPRIGHT 318'HEX NUT (STAINLESS) r 318'O.D.LOCKWASHER 718'O.D.FLATWASHER Protective Surfacing(determined by fall height i (3f8' STAINLESS) requirements)must cover hardware at all times i x 2 314'WEDGE ANCHOR STAINLESS) ------------------- t — __ ----- K t BASE PLATE ASSY DRILL 31W DIA.HOLE 2'DEEP USING BASE PLATE AS TEMPLATE t a ' ,v t r WIRE MESH •G v d � 4'MtN,CO CR E SLAB 4610 c & 3' CRUSHED MY x3r ROCK DETAIL 3 SIDE VIEW OF SURFACEMOUNT PAGE 2 Play&Park Structuress•544 Chestnut Srest•Chattanooga.TN 37402.800.727.1907•playandparic.com•customerservice*playandpark.com 8 DUN% . Clamp Assembly Details PLAY SYS?EMS EXISTING318'x 1 112" POST.. ,�. P.B.H.C.S.WIPATCH 318"x 9SET (812053) SCREW(811648) 19, PIPE b PIPE - CLAMP,-%1, CLAMP�`'�, ""' 318"HEAVY HEX NUT �TUBE E'3tOM COMPONENT {J ` 0 114'x 314"FiRiVE —' O RIVET(168449) DRILL I/4•DIA.HOLE TO RECEIVE DRIVE RIVET TYPICAL DURAMAX PIPE CLAMP ASSEMBLY NOTE.CLAMPS AND HARDWARE SHOWN ARE PACKAGED WITH INDIVIDUAL COMPONENT 3111"x 1 114" HARDWARE COMPLETE PACKAGES. P.8-H.C.S.%WPATCH {8120$1� 0 4 0 Ca, Q EXISTING UPRIGHT ExDECKlsnNG 318"FIAT WASHER (1 114"O.D.)(817424) THREADED INSER f--`` 0 TYPICAL DURAMAX DECK CONNECTION Issuedfitwise .4/4/2016 SHEET 1 OF 2 Ploy&Park Structures•544 Chestnut Street•Chattanooga.TN 37402.800.727.1907•playandpark com•customerservice@playandpark.com PLA/tl�iWf` Clamp Assembly Details TEMS DRILL 114"DIA.MOLE TO RECEIVE DRIVE RIVET PANEL CLAMP—., 114*x 3A"DRIVE RIVET(168449) ,t 0 318"x1 112" P.B.H.C.S.w/PATCH 3113`HEAVY HEX NUT (812053) NOTE'CLAMPS AND HARDWARE SHOWN ARE EKISTING PACKAGED WITH INDIVIDUAL COMPONENT UPRIGHT HARDWARE COMPLETE PACKAGES. TYPICAL DURAMAX PANEL CLAMP ASSEMBLY 3!8`x 1 112' P.B.H.C.S.wlPATCH ,.(812853) 318'HEAVY HEX NUT a �. I/4"HINGE_. .� DRILL USING 114"DRILL SIT PEN CLAMP HALF VATH TO RECEIVE DRIVE RIVET t PIPE SLEEVE pub 114'x 314"DRIVE UPRIGHT RIVET(168449) t TUBE FROM TUBE FROM COMPONENT 3t8`x 31a"S T SCREW(811549) ` -" 318"x 318"SET SCREW(811549) DOUBLED SIDED PIPE CLAMP DURA1ttAX APPLICATION:To attach two components at 90 degrees to each other on the same square deck Use when damp conflicts do not allow you to use seperate damps for each component. ASSEMBLY INSTRUCTIONS:Use two regular Pie Clamps and remove hinge pints.Select damps with pipe sleeves to create the Double Sided Pipe Clamp.Insert hinge pin balls into damps as shown above. TYPICAL DURAMAX DOUBLE SIDED PIPE CLAMP ASSEMBLY IssuedlRe&ed:4/4/2016 SHEET 2 OF 2 Play&Park Structures•544 Chestnut Street•Chattanooga.TN 37402.800.727.1907•playandpark.com•customerservicet3playandpark.corn 1 SUPER"" # Clamp Assembly Details PLAY SYSTEMS ,. UPRIGHT RING CLAMP RING CLAMP (309411)...' (344911) w 114"x 1 1/4"PSHCS LOCATE PRE DETERMINED THREADED SIDE (812083) .... DRILL POINT AND DRILL OF CLAMP `~ 114"x t'DRIVE I1jDRIVE RIVET RECEIVE RIVET(805302) !►mss REMOVE ANY EXCESS PAINT BEFORE FASTENING BOLT. `` —-- USE A 114"-20 TAP TO CLEAR THREADS IF NECESSARY. NOTE:THE USE OF LOCTITE IS IMPORTANT. NOTE.MAKE SURE THE PLAY 8 PARK.STRUCTURES LOGO IMPORTANT;ORIENTATION OF SOLT IS CRITICAL. IS ORIENTED CORRECTLY AND VISIBLE FROM GROUND LEVEL. NOTE:THE RING CLAMP WILL HAVE A SMALL GAP AT THE CONNECTION POINT AFTER ATTACHED.THE GAP IS DESIGNED FOR DRAINAGE AND TO ENSURE A PROPER FIT. TYPICAL SUPERMAX RING CLAMP ASSEMBLY 318"FLAT WASHER 3M'x 1 114" NOTE DECK ADAPTER WILL FIT INTO 0 114"O.D.)(817424) P,B.H,C.5_WIPATCH GROOVE IN TOP OF RING CLAMP AND -(812451 SECURE WITH SET SCREWS EXISTING. da ♦ o a o 0 UPRIGHT $a o0 0 31F LOCKWASHER EXISTING (817334) DKK DECK ADAPTER (309921) RUNG CLAMP (309411) 1/4'x 314"SET SCREW(811548) CD NOTE:ADAPTERS AND HARDWARE SHOWN ARE PACKAGED WITH INDIVIDUAL COMPONENT HARDWARE COMPLETE PACKAGES IsmxdlRevisW:4/11/2016 TYPICAL SUPERMAX DECK CONNECTION SHEET 1 OF 2 Play&Park Structures•544 Chestnut Street•Chattanooga,TN 37402•BQD.727.1907•playandpa&com-customerserviceOplayandpa&com 21 SU -I to Clamp Assembly Details PLAY SYSTEMS EKISTING 318'x 2 114" UPRIGHT P.$H.C.S.w/PATCH (812056) PANEL ADAPTER (309919) 318`FLAT WASHER PING CLAMP (1 IW O.D.)(817424) (309911) '1B1 PANEL 3d8"BARREL NUT 1/4 x 3t4'SET (804804) SCREW(811545) NOTE:PANEL ADAPTER WILL FIT INTO GROOVE IN TOP OF RING CLAMP AND SECURE WITH SET SCREWS, PANEL MUST ATTACH TO THE DECX SIDE OF THE ADAPTER. TYPICAL SUPERMAX PANEL ADAPTER ASSEMBLY NOTE PIPE ADAPTER WILL FIT INTO GROOVE IN TOP OF RING CLAMP AND SECURE WITH SET SCREWS EXLMj NG UPRIGHT RING CLAMP PIPE ADAPTER (309911)` ' (309915) f° 318'BARREL NUT _(804804) f COMPONENT 3tW LOCKWASHER• -- (817334) , 318"x 1314" 114`z 3f4-SET P.B.H.C.S.w1PATCH SCREW(811545) (812054) 318"FLAT�A5HER (81-1410) TYPICAL SUPERMAX PIPE ADAPTER ASSEMBLY ks%*&Revis : 4111/2016 SHEET 2 OF 2 Play&Park Structures•544 Chestnut Suet•Chattanooga,TN 37402•800.727.1407• playandpark.com•customerservice*playandpark.com 1 &park DETAILED MAINTENANCE RECORD plplay Play Area Site Name Play Area Location or Description Date Inspector Item Number OK Problem Solution Date Initials Repaired Play&Park Structures•544 Chestnut Stroet•Chattanooga.TN 37402•800.727.1407 •playandpark.com•custom erservice®playandpark.corn . . . . . _ . . . . . . . . . . . . . . . . . . . . . . . _ . . . . . . . . . _ . . . . . . � �: �< 2 \ � � � � �^ \ � / \ . : . � . . ^ \ , � : . . ( . > t \ ^ , a : / �> $ � � ^ ° � : a w \ » \ ° � . » . - . � \ ^ � �, � t } \ ~ : : \ r / 2 v � � � � ~ v � i § / ~ � � ^ : / / ( / \ _ \\ : 2 \r ��. . - �� � » � . � � . � . . � : � � � . � . . . � » � � y , yy � . . � . § . . §�\ . < �� �y > - � : . . �y . . . � � °\ � . . \ � % ƒ� � � \ . . � � ƒ � ^ . - PLAYGROUND MAINTENANCE CHECKLIST play&park structures .r.,ecopm— Maintaining your playground equipment as well as its surrounding area is essential to minimizing the risk of injury to users as well as maximizing its useful lifespan. Play&Park Structures recommends the following maintenance procedures be followed: On a daily basis: A responsible individual should conduct a brief visual check for structural defects,signs of vandalism and litter of foreign matter that needs to be removed. On a waeidy basis: A responsible individual should complete this checklist.Any required repairs should be detailed on the separate Detailed Maintenance Record,and once they are completed, both should be filed for future reference.A separate file and form should be kept for each play structure at each location. IMPORTANT: Always refer to-and comply with-the separate Safety Guidelines and ASTM and CPSC Guidelines. The play structure(s)should be barricaded so that it cannot be used while repairs are being completed. Item to be Checked OK Repairs Required Date (use the followingpage to record a brief description of the necessary repairs) Repaired A. Play Structures in General Post and component footings are not exposed,cracked or loose 1. Clamps show no signs of slippage,cracking,or failure Damp drive rivets and hardware are secure 3. Welds are Intact and free of cracks a.Slide and Deck Enclosures b.Overhead Activities e.Climbers 4. No rust or corrosion S. No splintered,cracked,gouged or otherwise deteriorated plastics;check for integrity of the plastic,keep plastic dean of any extraneous substances,verify that any deformation does not create an entrapment as specified on ASTM-F-1487 section b. 6. No scratched,chipped,or peeling paint 7. Metal parts show no visible cracks,bending,warping or breakage 3. No missing bolts,nuts,etc 9. All bolts,nuts,and fasteners are tight 10.All joints are secure(pay special attention to sectional slides,flush mounted decks,and pipe connections) 11.Ali swivels,bearings,grease fittings,and moving parts are well lubricated and not excessively worn(pay spacial attention to tire swings,tort swings,strap swings,track rides,and trapeze rings) 12. No broken or missing parts 13. No sharp edges or unsafe protrusions(check metal comers,bolts,etc.) 14.No exposed mechanisms,junctions of moving parts or components that will pose possible pinch or crush points B. Play Events 1. Plastic is not cut or cracked . Ali slide supporWanchws are intact and secure 3. AH'S'hooks are dosed and not excessively worn 4. Clatter bridge chain and connections are not excessively worn,especially at connection ants S. Connectors and Chain have free movement C. Surmunding Area 1. Resilient surfacing material Is not scattered or excessively wom 2. Resilient surfacing material is adequately deep and retains its fall absorbing abilities as specified at the time of instaltation 3. Border around playground is in good condition and has not come loose 4. No roots,rocks,or other objects that may cause a tripping or Injury hazard S. Area is clean of litter(no broken glass or bottles,etc.) Play&Park Stnxtures•544 Chestnut Street•Chattanooga,TN 37402•600,727.1407•playandpark.com•customerservice®playandparkcom tW .tom X u Ali e" N Olt, SuperAoft,A(- Play Systems �'"« MODEL NO. 609 19 Z!G ZA G ADAPTER PARTS LIST REF No. PART NO. DESCRIPTION REQ'D NUMBER Hardware Comp to 1 305846 1 2 305847• 318"x 1/2"P.B.H.C.S.w/Patch 2 812049` 318"x 314"P.B.H.C.S.w/Patch 4 8127052- 3V x 1"P.B.H.C.S.w/Patch 2 812050` 3/8"Flat Washer 4 817410` 3/8"Flat Washer 1 1/4"O.D. 2 817424' 318"Barrel Nut 4 804804" 318" Lock Nut 2 804353' ®®t3/8"_Tee Nut 2 804556` 1/2"Flatwasher 2 817412• Unless Otherwise Specified,All Units of Measure are Each Included in Hardware Warning:Small parts and hardware items may present a potential choking hazard Promptly remove all unused parts from play area.Any bolt and protruding more than two fug threads beyond the face of the nut causes risk of clothing entanglement:Promptly cut-off/lush,file smooth,and treat to prevent corrosion. Note:Peen Tee-Nuts and Flatwashers to match radius of pipe after assembly is complete. Note.Loctite(supplied by others)should be used on any non-patch hardware. Issued/Revised: 04/03/13 SHEET 1 OF 4 4 r* 9Play Systems ft iNM MODEL NO. 60919 Z1G ZAG ADAPTER SPECIFICATIONS: Zigzag Adapter Is made from 3/16"Thick H.R.Steel. INSTALLATON INSTRUCTIONS The Zigzag is a piece of hardware designed to avoid damp conflicts.It has been designed and tested particularly for the use on Deck Clamps,HOPE Panels, Decks,and Barriers that attaches to Decks with Tabs. Important;Do not use The Zigzag with Pipe Clamps and Deck Clamps altogether.There are three types of connections that have been tested:Panel-to-Panel Clamp,Panel To Deck.and Barrier Tab to Deck.Avoid the use of the Zigzag on places where Its use has not been Intended. HDPE PANEL TO PANEL CLAMP 1.Attach Zigzag onto a Panel Clamp using 3/8"x 3:"P.B.H.C.S.wlpatch,3/8"Fiat Washer,and 31W Barrel Nut.See Detail 058. 2.Attach HDPE Panel onto Zigzag using 3/8'x 3/4"P.B.H.C.S.w/patch,3/8 Flat Washer.and 3/8"Barrel Nut.See Detail 058. HDPE PANEL TO DECK 1. Attach Zigzag onto a Deck using 3/8"x 1"P.B.H.C.S.wlpaGah,31W Flat Washer,and 3/8"Lock Nut See Detail 059. 2.Attach HDPE Panel onto Zigzag using 3B"x 3/4"P.B.H.C.S.w/patch, 318 Flat Washer,and 3/8"Barrel Nut.See Detan 059_ BARRIER TAB TO DECK 1.Attach Zigzag onto a Deck using 3/8'x 1"P.B.H.C.S.w/patch,3/8"Flat Washer,and 318"Lock Nut.See Detail 060. 2.Attach Barrier Tab onto Zigzag using 3/8"x'A"P.B.H.C.S.w/patch and 318"Flat Washer and fastening the opposite side with a 318'Tee Nut and a'r4"Flat Washer.See Detail 060. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and tighten as necessary. Always check parts for breakage or wear,and immediately put equipment out of service until any faulty parts are repaired or replaced. Check for rust,paint loss, and touch up if necessary with paint. Check for welded areas and verify Integrity_ Check all decks for peeling of Plastisol coating and touch up with Plastisd If necessary. Check for obstructed holes on deck,dean if necessary. Check for openings on plastic junctions and use dear silicone to fill. Check for cracks,gouges,or breakage on plastic. Check for Integrity of plastic and keep plastic keep of any extraneous substances. Verify that any deformation does not create entrapment as specified on ASTM F1487 section B. Periodk:ally check resilient surfacing for appropriate depth,and remove extraneous materials that could cause Injury,Infection,or disease. Maintain detailed Installation,Inspection,maintenance, and repair records for each public-use playground equipment. Issued/Revised: 04/03/13 SHEET 2 OF 4 Supe Play Systems mi MODEL NO. 60919 ZIG ZAG ADAPTER ZIG ZAG 058 HDPE PANEL 059 ' *ZIG B FINISHED ASSEMBLY DETAIL NUMBER DECK 060G Issued/Revised: 04/03113 SHEET 3 OF 4 .R4vePlay Systems Modd f4w rmgt MODEL NO. 60919 ZIG ZAG ADAPTER 318"BARREL NUT ZIG ZAG ADAPTER (817410) (804804) ( 7) ZIG ZAG ADAPTER 3/8'x3!4"P.B.H.C.S. (305847} 3/8"x 3/4"P.B.H.C.S. 318"FLATWASHER w1PATCH(812052) wIPATCH(812052) (817410) 318"BARREL NUT 3/8"x CH 8120 C.S. (804804) w/PATCH(812052) i 318"LOCKNUT L 3/8•x i"P.B.H.C.S. (804353) w/PATCH(812050) 318"FLATWASHER 318"BARREL NUT (1 1/4"Q.D.) 3/8"FLATWASHER ( 804) (817424) (817410) 318'FLATWASHER (817410) 059 458 318"FLATWASHER (1114-0 D (817424) ZIG ZAG ADAPTER 3/8"LOCK NUT (305847) (8043x3) 318"FLATWASHER 1 (817410) 318"TEE-NUT 318"x 12"P.B.H.C.S. (804556) w1PATCH(812049) 112"FLATWASHER (817412) 318•x 1"P.B.H.C.S. wtPATCH(812050) aso IssueaevisM: 04/03113 SHEET 4 OF 4 buramax 62015 KICKPLA TE B" PARTS LIST No. PART DESCRIPTION READ N MBER x to Hardware Complete I 1 1 302183 31t3"_Flat Washer 0 1/4"O.D.) � 8 817424' 318"Lock Nut 4 804353' 318"x 314"P.B.H.C.S.w/Patch 1 4 1 852052' Unless Otherwise SpeclNe4 All Units of Measure are Each 'Included In Hardware Warning:Small parts and hardware items may present a potential choking hazard. Promptly remove all unused parts from play area. Any bolt end protruding more than two hull threads beyond rhe face of the nut causes risk of clothing entanglement. Promptly cut-off flush, file smooth,and treat to prevent corrosion. Note:Peen Tee-Nuts and Flatwashers to match radius of pipe alter assembly is complete. Note:Loctite(supplied by others)should be used on any non-patch hardware. INSTALLATION INSTRUCTIONS: 1. Refer to the main drawing to locate decks,which are spaced 8"apart.These will require lOckplate(s).Attach lockplates after decks have been installed,but before deck damps have been pinned,In case adjustment in deck heights Is required to match up holes In deck flanges with holes In Mckplate. 2. Attach Kickplate to decks using 318"x 314"P.B.H.C.S.w.Patch with 318"(1 114"O.D.)Fiat Washers and 3/8"Lock Nuts. Formed sidle of kickplete goes behind edge of lop deck No portion of the Kickplate should be protruding in a manner which could cause a user to receive a cut,scrape or trip over any edge.Any rough edges should be wed smooth,and any protruding corners should be flattened. 3. Eliminate sharp points and sharp edges(burring)on Installed hardware like bolts,nuts,etc.Install resilient surfacing material within the use zone of play structure in accordance with ASTM specifications F1292 appropriate for the fall height of each structure.Refer to the Safety Guidelines. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and lighten as necessary.Always check all parts for breakage or wear,and Immediately put equipment out of service until any faulty parts found are repaired or replaced.Check Plastfsol-coating for bare spots and touch-up with Piastisol If necessary.Clear any trapped debris from deck perforations.Check periodically resilient surfacing for appropriate depth and remove extraneous materials that could cause Injury,Infection,or disease. Maintain detailed installation,inspection,maintenance,and repair records for each pubfic-use playground equipment Issued/Revised: 7123/15 SHEET 1 OF 2 buramax 62015 KICKPLA TE 8" I I POST&DECKS I (SOLD SEPERATELY) I ( � ! I 3 112"O.D. I I I ! DECK CLAMP - I I 1 i I I 3/8'x 1'P.B.H.C.S. w/PATCH(812050) I ( I 318"FLATWASHER - (1 114'Q.O.)(817424) ! DURAMAX -- I I KICKPLATE I i 3/8"FLATWASHER (1 1/4"O.D.)(817424) 3/8"LOCKNUT (804353) TOP DECK U 318"LOCKNUT(804353) w/318"FLATWASHER Ir (1 114'O.D.)(817424) (TYPICAL) KICKPLATE 318"x 314'P.B.H.C.S. Ono— +1 w/PATCH(812052)w/ DETAIL 3/8'FLATWASHER (1 114"O.D.)(817424) (TYPICAL) Issued/Revised: 7123115 SHEET 2 OF 2 buramax 62026 DURA MAX PIPE WALL PARTS LIST No. PART DESCREgMN DuraMax Pipe Wall 1 307906 1f2"O.D.Deck Clamp 2 301731 Hardware efe 1 308084 114"x 3/4"Drive Rivet4 168449' Heavy Hex Hex Nu! 4 �^ 804200' 3/8"x 1 1/2'P.B.H.C.S.w/Patch 4 812053' 3/8"Flat Washer 2 817410' 318"Lock Nut 2 804353` 3V Flat Washer(1 114'O.D.) 4 817424 318"Barrel Nut 2 804804' 318"x 1"P.B.H.C.S.w/Patch 2 812050' Unless Otherwise Specltled,All Units of Measure are Each 'Included in Hardware Warning:Small parts and hardware Items may present a potential choking hazard. Promptly remove alt unused parts from play area. Any bolt end protruding more than two full threads beyond the face of the nut causes risk of clothing entanglement. Promptly cut-off Hush, file smooth,and treat to prevent corrosion. Note:Peen Tee-Nuts and Flatwashers to match radius of pipe after assembly/s complete. Note:Loctite(supplied by others)should be used on all thread hardware. INSTALLATION INSTRUCTIONS: 1. Attach Deck Clamps to upright post and Pipe Wall using Detail 001 and 043.Ensure Pipe Wall is 38'or greater above deck_ Attach bottom tabs of Pipe Wail to deck using Detail 026. After ensuring Pipe Wall Is square and level,tighten all fasteners. IMPORTANTI Avoid creating any gaps between the components,which fall between 3-112"and 9".It has been shown that such gaps create entrapment points,which can trap a child and cause Injury. 2. When the structure is finished and satisfactkxy.Install Drive Rivets In all damps to ensure damps cannot slide down posts. See Deck Clamps sub-assembly sheet. It is very important that all Drive Rivets be Installed prior to allowing use of the equipment,as clamps are not designed to support substantial weight without them.Install resilient surfacing material within the use zone of play structure In accordance with ASTM specifications F1292 appropriate for the fall height of each structure.Refer to the Safety Guldeiines.Eliminate sharp points and sharp edges(burring)on Installed hardware like bolts, nuts,etc, MAINTENANCE PROCEDURE: PeriodlcaKy check hardware for tightness,and tighten as necessary.Always check all parts for breakage or wear,and immediately put equipment out of service until any faulty parts found are repaired or replaced.Check for rust,paint loss and touch-up if necessary with paint.Check for welded areas and verify integrity.Check periodically resilient surfacing for appropriate depth and remove extraneous materials that could cause Injury,infection,or disease. Maintain detailed Installation, Inspection,maintenance,and repair records for each public-use playground equipment. lssued/Revised: 04/12/11 SHEET 1 OF 3 buramax 62026 DURAMAX PIPE WALL 043 -� 3 1/2"O.D. DECK CLAMP I I I 3 1/2"D.D.POSTS (SOLD SEPARATELY) I I I t 1 I I I 001 t t 1 I I I f I I I I I 1 I 1 I 1 i I I i i PIPE WALL DECK t I I t r I (SOLD SEPERATELY) 1 I i I 1 I � 026 PIPE WALL ASSEMBLY Issued/Revised: 04/12111 SHEET 2 OF 3 0INCH 1 2 3 4 5 6 lei,►,t. �, I,►,1111L. �,►�I,►,�,►,I�►,�, I,►, ,►,I.►. ,►,If►,�,,,I,,,�,�,1,►,�,►.I.►,�f►,l If 1111 1 11111111111111 1 111111111111111111111111 111111111111111 11111 111111 111 Il If 11 111 IT IIIIIIIIII I 1111111 1111111111 111 It 111111 11111 1 pill If OCM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 62026 DURA MAX PIPE WALL DECK CLAMP 318"x 1 1/2'P.B.H.C.S. TYP. w/PATCH(812053) 3/8'HEAVY DRILL USING HEX NUT 1/4'DRILL BIT (804200) TO RECEIVE 3!8`FLAT WASHER DRIVE RIVET (817410) UPRIGHT POST ENCLOSURE TYP. OR BARRIER 1/4"x 3/4' DRIVE RIVET (168449) 3/8`BARREL NUT(804804) DECK CLAMP gQ1 3/8"x 1 1/2'P.B.H.C.S. w/PATCH(B12053) 043 PLATFORM NOTE: HANDHOLD TOP EDGE OF PIPE WALL MUST BE 38"[965mm] OR GREATER ABOVE ELEVATED PLATFORM SURFACE FOR USE BY 5-12 YEAR OLDS. for 3/8`FLATWASHER t7%%Pr (1 1/4"O.D.) TOP EDGE OF PIPE WALL MUST BE 29"[736mm] a.Vz a (817424) OR GREATER ABOVE ELEVATED PLATFORM SURFACE FOR USE BY 2-5 YEAR OLDS. I 3/8"LOCK NUT (804353) I/8'FLATWASHER 3/8`X 1'P.B.H.C.S. (1 1/4`O.D.) w/PATCH(812050) (817424) 026 I$Su@d/RevLwd: 04/12/11 SHEET 3 OF 3 0 WK UZ buramax 62432 S TORE PANEL PARTS LIST o. PART DESCRIPTION REQ'D NUMBER Duramax Store Panel 1 306751 DNA Store Panel Counter 1 302608 06-6i-free Angle Bracket 3 302334 3 1/2"O.D.Panel Clamp 4 302567 Hardware Complete 1 302613 1/4"x 314"Drive Rivet 4 168449` 318 Barrel Nut 10 _804804 318'Fiatwasher 10 817410` 318"Heavy Hex Nut 4 804200` 318"x 1 112"P.B.H.C.S,w/Patch $ 812053` 318"x 3N"P.B.H.C.S.w/Patch 6 812052` Unless Otherwise Specified,All Units of Measure are Each 'Included in Hardware Warning:Small parts and hardware Items may present a potential choking hazard. Promptly remove all unused parts from play area. Any bolt end protruding more than two full threads beyond the face of the nut causes risk of clothing entanglement Promptly cut-off flush,file smooth,and treat to prevent corrosion. Note:Peen Tee-Nuts and Fletwashers to match radius of pipe after assembly Is complete. Note:Loctite(supplied by others)should be used on all threaded hardware. INSTALLATION INSTRUCT/ONS: NOTE:This Panel Is for ground-level use only.Do not use as a deck barrier. 1.Attach Panel Clamps to Storerfable Panel using the 318"x 1 112"P.B.H.C.S.w/Patch with 318"Flat Washers and 318"Barrel Nuts as shown on assembly drawing. 2.Fasten Panel Clamps to Upright Posts(refer to separate Panel Clamp fastening detall). IMPORTANTI Avoid creating any gaps between the components,which fall between 3-112"and 9".It has been shown that such gaps create entrapment points,which can trap a child and cause Injury. 3.Plumb the StorelTable Panel and tighten Panel Clamp fasteners. 4.Attach Store Panel Counter to StorelTable Panel using 90°angle brackets,318"X 314"Hex-pin bolts,and Barret nuts as shown in the assembly drawing.Note that bolts should always go to the bracket side. 5.When the structure Is finished and satisfactory.Install Drive Rivets in all clamps to ensure damps cannot slide down posts. See Panel Clamps sub-assembly sheet. It Is very Important that all Drive Rivets be Installed prior to allowing use of the equipment,as clamps are not designed to support substantial weight without them._ 6.Eliminate sharp points and sharp edges(burring)on installed hardware like bolts,nuts,etc.Install resilient surfacing material within the use zone of play structure In accordance with ASTM specifications F1292 appropriate for the fail height of each structure.Refer to the Safety Guidelines. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and tighten as necessary.Always check all parts for breakage or wear,and immediately put equipment out of service until any faulty parts found are repaired or replaced.Check for rust,paint peeling and touch-up If necessary with paint.Check for welded areas and verify Integrity.Check for cracks,gouges or breakage on plastic, check for integrity of the plastic,keep plastic dean of any extraneous substance,verify that any deformation does not create entrapment as specified on ASTM F1487-98 section 6.Check periodically resilient surfacing for appropriate depth and remove extraneous materials that could cause Injury,infection,or disease.Maintain detailed installation„Inspection,maintenance,and repair records for each publause playground equipment. Issued/Revised: 04111111 SHEET 1 OF 2 buramax 62032 STORE PANEL 3 1i2"0.D.POST (SOLD SEPARATELY) 3 12"O.D.PANEL ( CLAMP(302567)TYP. I I STORE PANEL COUNTER(302608) I I ( I I ' ! i I I I I I I I \ ( I � I I ! I ! LJ - DURAMAX STORE 3/8`X 1 1/2'P.B.H.C.S. PANEL(306751) w/PATCH(812053)TYP. 3/8"FLATWASHER (817410)TYP. 90`ANGLE BRACKET (302334)TYP. 3/8"FLATWASHER NOTE: (817410)TYP. THIS COMPONENT IS USED 31W X 314"P.B.H.C.S. AT GROUND LEVEL ONLY. w/PATCH(812052)TYP. ELEVATION VEIN 318"BARREL NUT (804804)TYP. Issued/Revised: 04/11/11 SHEET 2 OF 2 Duramax 62041 FIREMAN'S POLE (2'8" 34" and 4' DECK) Parts List DESCRIPTION QTY PART NUMBER ENTRY ARCHWAY WITH SOCKET 1 313655 FIREMAN'S POLE 1 302771 3 1/2"O.D.DECK CLAMP 2 301731 HARDWARE COMPLETE 1 302777 3/8"x 1"P.B.H.C.S.w/PATCH 2 812050 318"x 1 1/2"P.B.H.C.S.w/PATCH 5 812053 3/8"FLAT WASHER 3 817410 3/8-FLAT WASHER(1 1/4"O.D.) 4 817424 3/8"LOCK NUT 2 804353 3/8"BARREL NUT 3 804804 318"HEAVY HEX NUT 2 804200 114"x 3/4"DRIVE RIVET 2 168449 Unless Otherwise Specified,AN Units of Measure are Each 'Items listed below Hardware Complete line are included with Hardware Complete Number Waming:During Installation,Hardware And Small Parts Are Choking Hazards For Young Children.Store Unused Parts Appropriately Until Assembly is Completed.Once Assembly Is Completed,Remove Any Unused Parts From The Play Environment And DisposelSeve Them In A Secure Location.Any bolt end protruding more than two tug threads beyond the face of the nut causes risk of clothing entanglement Promptly cut-off flush,file smooth,and treat to prevent corrosion. Note:Peen Tee-Nuts and Flatwashers to match radius of pipe after assembly Is complete. Note:Loctite(supplied by others)should be used on any non-patch hardware. INSTALLA77ON INSTRUCTIONS: 1. Determine which deck is to receive the Fireman's Pole. Refer to your Top View drawing for location. 2. Dig footing holes for Fireman's Pole 6 Post locations in Top View.Note:Depth shown is for 4'deck,increase depth for lower deck height or cut-off pole accordingly. 3. Using a 7116'drill bit,ream out any excess"Plastisol"coating from all holes used on the Deck.Be careful not to expose the steel. 4. Using Detail-001 and Elevation View,locate and fasten two Deck Clamps to Upright Posts using 3/8"x 1-1/2"P.B.H.C.S. w/Patch,and 318'Heavy Hex Nut 5. Using Detail-797,attach Entry Amway to Upright Posts using Deck Clamps and fasten with 3t8'x 1-1/2"P.B.H.C.S w/Patch,3/8"Flat Washer,and 3/8"Barrel Nut. 6. Using Detail-026,attach Entry Archway to front of deck using 3/8"x 1"P.B.H.C.S,w/Patch,3/8'Flat Washer(1-1/4'O.D.), and 3/8'Lock Nut, IMPORTANT! Avoid creating any gaps between the components which fall between 3-1/2"and 8". It has been shown that such gaps create entrapment points which can trap a child and cause injury. IssuedlReVmed: 12/15/2015 SHEET 1 OF 5 Duramax 62041 FIREMAN'S POLE (2'8", 34'; and 4' DECK) 7. Place Fireman's Pole into dug hole,and attach swaged end into Entry Archway socket with 3/8"x 1 1/2'P.B.H.C.S w/Patch, 3/8'Flat Washer,and 318"Barrel Nut as shown In Detail-066. 8. Plumb and level the entire assembly and tighten all fasteners. 9. Pour concrete footings within 4"to the top and taper away from posts for water drainage.Allow to cure at least 48 hours before use. 10. When the structure is finished and satisfactory,install Drive Rivets in all damps to ensure clamps cannot slide dowq posts. See Ring Clamp subassembly sheets. b is very Important that all Drive Rivets be Installed prior to allowing use of the egulpment as clamps are not designed to support substantial weight Wthout them. Install resilient surfacing material within the use zone of play structure In accordance with ASTM specifications F1292 appropriate for the fall height of each structure. Refer to the Safety Guidelines. Eliminate sharp points and sharp edges(burring)on installed hardware like bolts, nuts,etc. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and tighten as necessary.Always check all parts for breakage or wear,and immediately put equipment out of service until any faulty parts found are repaired or replaced.Also Check all metal parts for rust,paint loss and touch-up if necessary with paint.Check forwekted areas and verify integrity. Check periodically resilient surfacing for appropriate depth and remove extraneous materials that could cause injury,infection,or disease.Maintain detailed installation,inspection, maintenance,and repair records for each public-use playground equipment." Isst"Revised 12115/2015 SHEET 2 OF 5 ......... .............. 11111 Duramax 62041 FIREMAN'S POLE (2'8'; 3'4'; and 4' DECK) r oss;� ENTRY ARCHWAY w/ SOCKET(313655) ooi� I I 1l2"O.D.DECK FIREMAN'SS2POLE I I ( CLAMP(301731) ol 1 GAP BETWEEN UPRIGHT AND r SHALL BERLESS THAN 3 1/2" I i 1 I `026 I II � II II II II LJ FINISHED ASSEMBLY COMPONENTS SHOWN IN HIDDEN LINES ARE SOLD SEPARATELY O =INSTALLATION DETAIL Issued/Revised: 12/15/2015 SHEET 3 OF 5 Duramax 62041 FIREMAN'S POLE (2'8'; 3'4'; and 4' DECK) 36 in [91.44 cm] 018 in [45.72 cm] REF. N ` .__� 201/8 in [51.09 cm] 014 in 18 in 135.56 cm] [45.72 cm] PLAN VIEW CONCRETE REQUIRED 0.07 CUBIC YARDS (0.05 CUBIC METERS] Fa F� i { 63 114 in 1 i 3 in [160.65 cm] I I 39 518 In 17.69 cm] ' 1100.59 cm] HOLD DECK HEIGHT 10 in I ! I 125.40 cm] I 1 RESILIENT SURFACE 30 in [76.20 cm] _ BRICK OR EQUIVALENT ELEVA77ON VIEW Issued/Revised: 12115/2015 SHEET 4 OF 5 Hl�l�f���l���l���l�l�f ��l�l�f�� I,I�I���l��lil�l��il.i� l���l�� f���[���I��� I���I���I�� I�� OCM 1 2 3 4 5 6 7 8 8 10 11 12 13 14 15 62041 FIREMAN'S POLE (2'8'; 3'4'; and 4' DECK) UPRIGHT COMPONENT POST 3/8"HEAVY HEX NUT (804200) DECK CLAMP DECK 3J8"x 1"P.B.H.C.S. w/PATCH(812050) DRILL USING • 1/4"DRILL BIT TO RECEIVE DRIVE RIVET V 1/4"x 3J4" tVE 318"x 1/2" 31W L CK NUT RIVET(168449) P.B.H.C.S.w1PATCH 318"FLA WAS ER (804353) (812053) (1 114"O.D.)(817424) x,026 '",00l� 3/8"x 1 112" P.B.H.C.S.w/PATCH (812053 NOTE:BEND THE WASHER TO 3/8"FLAT WASHER MATCH THE CURVATURE OF 817410) THE OVERHEAD EXTENSION PIPE 318"x 1 1/2" P.B.H.C.S_w/PATCH (812053 ENCLOSURE 3/8"FLAT WASHER ,(817410) r' CLAMP t SWAGED i PIPE PIPE tt 318"BARRE NUT (804804) r 318"BARREL N T (804804) :T9 lssuecVRevised 12/15/2015 SHEET 5 OF 5 ILI \ \ ® / 114 il buramax 62101 EXTRA LARGE KICKPLA TE PARTS LIST No. PART DESCRIPTION REQD NUMBER Extra Large Mckplate(25 1/2'x 29') 1 305752 Hardware Complete 1 302183 3/8'x 314"P.B.H.C.S.w/Patch 4 812052" 3/8"Lock Nut 4 804353' 3/8"Flatwasher 1 114"(3,13.) 8 1 817424' Unless Otherwise Spec/lied,Alt Units of Measure are Each 'Included in Hardware Warning:Small parts and hardware items may present a potential choking hazard. Promptly remove all unused parts from play area. Any bolt end protruding more than two full threads beyond the face of the nut causes risk of clothing entanglement. Promptly cut-off flush,file smooth,and treat to prevent corrosion. Note:Peen Tee-Nuts and Flatwashers to match radius ofplpe after assembly Is complete. Note:Loctite(supplied by others)should be used on any non-patch hardware. INSTALLATION INSTRUCTIONS: 1. Refer to the main drawing to locate decks,which are spaced 24"apart. These will require Kickpiate(s), Attach Kickplates after decks have been Installed,but before deck clamps have been pinned,In case adjustment In deck heights Is required to match up holes in deck flanges with holes In Kickplate. 2. Attach Kickplate to decks using 3/8"x 3/4'P.B.H.C.S.with Patch with 3/8'(1 1/4'O.D.)Flat Washers and 31W Lock Nuts2. 3. Eliminate sharp points and sharp edges(burring)on Installed Hardware like Bolts,Nuts,etc. Install resilient surfacing material within the use zone of play structure in accordance with ASTM specifications F1292 appropriate for the fall height of each structure.Refer to the Safety Guidelines. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and tighten as necessary.Always check all parts for breakage or wear,and Immediately put equipment out of service until any faulty parts found are repaired or replaced. Check for rust,paint loss and touch-up if necessary with paint. Check periodically resilient surfacing for appropriate depth and remove extraneous materials that could cause Injury,infection,or disease. Maintain detailed installation,inspection,maintenance,and repair records for each publio-use playground equipment. issued/Revised: 7/23/15 SHEET 1 OF 2 buramax 62 101 EXTRA LARGE KICKPLA TE FINISHED ASSEMBLY TYPICAL I''I POSTS$DECKS 1 I (SOLD SEPARATELY) 1 t i t I i 1 I I I I � 1 / 4" 1 I KICK PLATE I I `�°.� �� � J (302932) I I I 1 i 1 L J 318'X 3/4'P.B.H.C.S. wIPATCH(812052) w/3/8"FLATWASHER (1 1W O.D.)(817424)TYP. DETAIL 'A' 3/8"LOCK NUT (804353) w/3/B"FLATWASIiER (1 1/4'O.D.) Dot— (817424)TYP. NOTE:ANY SHARP EDGES ON THE KICKPLATE MUST BE FILED.ENSURE THAT NO CORNEERS PROTRUDE FROM DECK FLANGE SURFACE AFTER KICKPLATE HAS BEEN BOLTED SECURELY. Issued/Revised: 7/23/15 SHEET 2 OF 2 buramax 62127r 62128, 62129, & 62130 HURRICANE SPIRAL SLIDE PARTS LIST NUMBER REQUIRED PART DESCRIPTION 62127 62128 62129 62130 NUMBER Spiral Slide1 1 1 1 168262 .._..... .. Spiral Slide Hood 1 _ 1 1 1 301198 Extension Platform 48" 1 0 0 0 302210 Extension Platform 56' 0 1 0 0 302317 Extension Platform 64" 00 1 0 302195 Extension Platform 72" 0�. 0 0 1 306942 Barrier 2 0 0 0 308050 Barrier 0 2 0 0 308055 Barrier 0 0 2 0 308060 Barrier 0 0 0 2 308065 PlVe ss Enclosure Support A 'y w 2 2 307933 Harxihold Assern .n _ _2 2 2 2 308401 Foothuck 1 1 0 1 200033 Footbuck 0 0 1 0 176384 Ground Socket 1 1 0 1 168601 Ground Socket 0 Q_-_ 1 0 _ 302217 Decklam Cp 4 4 4 ! 4 301731 Hamuere Complete 1 1 1 [ 1 302786 318"x 314"P.B.H.C.S,wt Patch 2 2 2 f 2 812052' 318"x 1"P.B.H.C.S.wl Patch 2 2 2 2 812056- 3V x 1 114'P.B.H.C.S.w/Patch 4 4 4 4 812051' 318"x 1 112"P.B.H.C.S.wl Patch 14 14 14 14 812053' 31W x 1314*P.B.H.C.S.wl Patch 4 4 4 ' 4 812054' 31W T-Nut 4 4 d 4 804556' 31W Lock Washer 13 1313 13 817334' -- —-- 318'FlacWasher � �. 6 6 6 _ 6 - 817410' 318"(1 114"OM.)Flat Washer 7 7 7 7 817424' 318'lock Nut _,_... . 2 _ 2 2 2 �� Hay H 318" evex Nut 4 _.. _..4_._ 4 I— 4 8042W 318'x 3 114'B.H.CS. 1 1 1 1 811060' 112'x 3112"Hex Bolt 2 2 2 2 801213' A 112'tock Washer 2 2 2 2 817342' 1/2`Hex Nut 2 2 2 2 804055' 318"Barrel Nut 4 4 4 4 804804' 114'x 314'Drive Rivet 4 4 4 4 168449' Unless Otherwise Specified,All Units ofMessure are Each "Included in Hardware Warning:Small parts and hardware items may present a potential choking hazard. Promptly remove all unused parts from play area. Any bolt end protruding more than two full threads beyond the face of the nut causes risk of clothing entanglement. Promptly cut-off flush,file smooth,and treat to prevent corrosion. Note:Aeon Tee-Nuts and Flatwashers to match radius of pipe after assembly/s complete. Note:Loctite(supplied by others)should be used on all threaded hardware. Issued[Revised: 11/15/13 SHEET 1 OF 7 buramax 62127, 62128, 62129, & 62130 HURRICANE SPIRAL SLIDE INSTALLATION INSTRUCTIONS: 1. Dig footings at locations shown In footing diagram.Note:hole for slide mast must be 36"diameter. 2. Using a 7/16"drill bit,ream out any excess Plastlsot-coating from all holes to be used In the Extension Platform.Be careful not to expose the steel. 3. Fasten the(4)Pipe Clamps to the main 3112"O.D.Upright posts supporting the adjacent deck on the main structure.Refer to the Elevation View for proper damp location.Do not fully tighten fasteners. 4. Attach the Tab Assemblies to Upper Deck Clamps using detail 236;Attach Support Assemblies to lower Deck Clamps using detail 236. 5. Fasten the Extension Platform to the adjacent main structure deck using(2)3/8'x 1"P.B.C.H.S.W/Patch,3/8'Wide Flat Washers,and 3/8"Lock Nuts as shown in detail 233.Do not fully tighten fasteners. 6. Fasten the Exit Support Bracket to the Exit Segment of the Hurricane Spiral Slide Bed way using 3/8"x 314'P.B.H.C.S.W/ Patch with 3/8'Flat Washers as shown in detail 024.Fasten the Ground Socket to the slide with 1/2"x 31/2"Hex Head bolts, 1/2'Lock Washers and 112"Hex Nuts as shown In detail 023.Fully tighten fasteners. 7. Place the assembled Hurricane Spiral Slide Into the footing holes and attach It to the Extension Platform using 318"x1 1/4" P.B.H.C.S W/Patch and 318"Wide Flat Washers as shown In detail 136.Attach the Hurricane Spiral Slide Hood to the Hurricane Spiral Slide using a 318"x 3 1/4"P.B.H.C.S.W/Patch with a 318"Wide Flat Washer.See detail 253.Fasten the Hurricane Spiral Slide Hood to the Extension Platform with 3/8"x1 114"P.B.H.C.S.W/Patch and 318"Wide Flat Washers. See detail 255.Do not fully tighten fasteners. 8. Attach Barriers to Support Assembly using details 178 and 237.Attach Pipe Enclosure to Hood using detail 254. 9. Plumb and level the entire assembly and tighten all fasteners. 10. Pour concrete footings within 4"to the trop and taper away from the posts to slow water drainage.Allow curing at least 48 hours before use. 11. When the structure Is finished and satisfactory,Install Drive Rivets to all damps to ensure camps cannot slide down posts. See Pipe Clamps sub-assembly sheeL it is very important that all Drive Rivets be Installed prior to allowing use of equipment as clamps aro not designed to support substantial weight without them. Eliminate sharp points and sharp edges(burring)on Installed hardware like bolls,nuts,eta Install resilient surfacing material within the use zone of play structure In accordance with ASTM specifications F1292 appropriate for the fail height of each structure.Refer to the Safety Guidelines. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and tighten as necessary.Always check all parts for breakage or wear,and immediately put equipment out of service until any faulty parts found are repaired or replaced.Check for rust or paint loss and touch-up if necessary with paint.Check welded areas and verify Integrity.Check Ptastlsat-coating for bare spots and touch-up with Piastisol if necessary.Clear any trapped debris from deck perforations.Check for cracks,gouges,or breakage on plastic, check for Integrity of the plastic,keep plastic clean of any extraneous substances,verify that any deformation does not create entrapment as specified on ASTM F1487 section 6.Check periodically resllint surfacing for appropriate depth and remove extraneous materials that could cause injury,infection,or disease.Maintain detailed installation,Inspection,maintenance,and repair records for each public-use playground equipment- Issued/Revised: 11/15/13 SHEET 2 OF 7 buramax 62127, 62128, 62129, & 62130 HURRICANE SPIRAL SLIDE TAB ASSY r 2,54 PIPE ENCLOSURE 236 �-- ONE-PIECE 001 178 t SPIRAL SLICE W/HOOD ENCLOSURE SUPPORT # ASSY f_ 253 1 i t ' 237 — t 3 255 t � t 233 136 023 FINISHED ASSEMBLY 62127 SHOWN 62128,62129,&62130 SIMILAR Issued/ReAsed: 11/15113 SHEET 3 OF 7 buramax 6212762128 , 62129, & 62134 HURRICANE SPIRAL SLIDE DIM'A" 23 114"[590mmj SEE CHART PART# DIM"A' 3 112"O.D.POSTS&DECK ��``~ � 62127 59 314"[1b17mm] (SOLD SEPARATELY) A` 6'[152mmj 62128 59 3f4"[1517mmj �� 62129 59 3/4"[1517mmj t� 62130 46 318"11178mmj 36"[914mmj ..J I 1 PLAN VIEW EXIT HEIGHT CHART 62127 SHOWN STANDARDD EXIT HEIGHT from SURFACING 62128,62129,&62130 SIMILAR ASTM 7"TO 15' CSA 175mm TO 380mm EN 350mm OR LESS 47 7/8"[1216mmj 1 1 48"[1219mm] ! SEE EXIT ; } HEIGHT ; t CHART ; 10"[254mm1 RESILIENT SURFACE; 30"[762mmj �- f r •. .I 14"[308mmj DIA. 18'1457mmj FOR FOOTBUCK I 18"[457mml FOR UPRIGHTS DIAMETER 36'[914mmj DIAMETER FOR SLIDE ELEVATION VIEW MAST FRONT VIEW 62127 SHOWN 62127 SHOWN 62128,62129,&62130 SIMILAR 62128,62129,&62130 SIMILAR Issued/Revised: 11/15113 SHEET 4 OF 7 0INCH 1 2 3 4 5 6 ��I�►�i���l�►.I.►.I.►.I.►���►�I�I�I���i���l�►�I�I�f,►�������►�I�I�I,►�������►�I��,IL �������►,ISI OCM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 62127, 62128, 62129, & 62130 HURRICANE SPIRAL SLIDE DECK CLAMP 1YP. ROTOMOLDED SLIDE 3/8"HEAVY DRILL USING GROUND SOCKET HEX NUT 1/4"DRILL BIT MUST BE 318"AWAY (844200) TO RECEIVE FROM SLIDE BEFORE NOTE: FIELD DRILL DRIVE RIVET DRILLING HOLES I 9/16'DIA HOLE IN MAST IN MAST BEFORE ERECTION.USE GROUND SOCKET HOLE 112"HEX NUT AS A TEMPLATE (804055) UPRIGHT POST 1/2"LOCKWAHER TYP. (817342) 114•x 3/4" OVERSIZED 1/2'x 3 1/2"HEX HEAD DRIVE RIVET HOLES (168449) BOLT(801213) GROUND SOCKET apt 3/8"x 1 1/2"P.B.H.C.S. wt PATCH(812053) 023 SLIDE PLATFORM tE 318"FLATWASHER (1 1!4'0.0.)(817424) 3/8"LOCKw 17�)318'X 3/4"P.B.H.C.S. W/PATCH(812052) S. R wtPATCH(812051) azo S Issued/Revised: 11/15/13 SHEET 5 OF 7 0INCH 1 2 3 4 5 6 "1411 lll 1141 0CM 1 2 4 5 6 7 8 9 10 11 12 13 14 15 62127, 62128, 62129, & 62130 HURRICANE SPIRAL SLIDE EXTENSION 3/8'x 1 1/2'P.B.H.C.S. DECK r PLATFORM JW03ATCH(812053) 1 31W LOCKWASHER (817334) a • 318"T-NUT 3/8'x 1"P.B.H.C.S. (804556) W/PATCH(812050) 3/8"FLATWASHER (817424) 3/8"LOCKNUT (804353) ATTACHMENT HANDRAIL OR ENCLOSURE 233 17$ - 318"x 1 1/2"P.B.H.C.S. w/PATCH(812053) NOTE:AFTER INSTALLATION IS COMPLETED, PEEN TEE 3/8"x 1 1/2"P.B.H.C.S. NUT TO MATCH RADIUS 3/8"FLAT WASHER w/PATCH(812053) OF PIPE. '� (817410) SUPPORT OR TAB ASSEMBLY 3B"BARREL 318"LOCKWASHER NUT(804804) PCLAMP DECK (817334) 318'TEE NUT (804556) 236 237 (ssued/Revised: 11/15/13 SHEET 6 OF 7 0INCH 1 2 3 4 I I 5 6 II I I I I I I I 1 I t I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I I I I I I 1111 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I II I 111111114 1111111111111141 111111111141111111111111111111 1111111111 If 111 1111 1111111111111111 11 till M I 1111111 IT oil 111111 110114111 1111 T 1111111 11"F OCM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 62127, 62128, 62129, & 62130 HURRICANE SPIRAL SLIDE HOOD HOOD SLIDE 318"FLATWASHER 3/8"LOCK DASHER (817424) (817334) 3/8"LOCKWASHER :tk (817334) 3/8'x 13/4"B.H.C.S. (8 t 2054) BARRIER 3/8"X 3 114"B.H.C.S 253 (811060) 254 HOOD PLATFORM 3/8"LOCKWASHER (817334) 3/8'FLATWASHER 3/8"x 1 1/4"P.B.H.C.3, (817426) (812051) z5� Issued/Re*W: 11/15/13 SHEET 7 OF 7 Z9 : : az : buramax 62 168 PLA YtNHEEL FOR 3 1/2"O.D. POST PARTS LIST No. PART DESCRIPTION REQ'D NUMBER Steering Wheel Assembly t 1 306869 31/2"O.D.Half Clamp 2 301765 Hardware Complele 1 178780 114"x 314`Drive Rivet 2 168449` 318"Rat Washer 4 817410` 318"Heavy Hex Nut 4 &)4200- 1/4"x 112"Drive Rivet 1 805301' 318"x 1 1!2"P.B.H.0 S.wl Patch 4 812053` Unless Otherwise Speciffed,All Units of Measure are Each "Included in Hardware Warning:Smalt parts and hardware Items may present a potential choking hazard Promptly remove all unused parts from play area_ Any bolt end protruding more than two full threads beyond the face of the nut causes risk of clothing entanglement Promptly cut-off flush,fits smooth,and treat to prevent corrosion. Note:Peen Tee-Nuts and Fletwashers to match radius of pipe after assembly is complete. Note:Loctite(supplied by others)should be used on any non-patch hardware. INSTALLATION INSTRUCTIONS: 1. Attach Steering Wheel to a pre-existing Upright Post using Half-Clamp,318"x i-112"P.B.H_C.S.w/Patch with 318"Flat Washers and 3/8"Heavy Hex Nuts as shown in the assembly diagram. 2. When the assembly Is finished and satisfactory,Install Drive Rivets in all damps to ensure damps cannot slide down posts. Also eliminate sharp points and sharp edges(burring)on Installed hardware like bolts,nuts,etc. See Clamp sub-assembly sheet.It is very important that all Drive Rivets be Installed before allowing use of the equipment as damps are not designed to support substantial weight without them. Install resilient surfacing material within the use zone of play structure In accordance with ASTM specifications F1292 appropriate for the fall height of each structure.Refer to the Safety Guidelines. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and tighten as necessary.Always check a l parts for breakage or wear,and Immediately put equipment out of service until any faulty parts found are repaired or replaced. Also Check all metal parts for rust,paint loss and touch-up If necessary with paint.Check for welded areas and verify Integrity.Check periodically resilient surfacing for appropriate depth and remove extraneous materials that could cause injury, infection,or disease.Maintain detailed Installation, Inspection,maintenance,and repair records for each pubilc-use playground equipment. tssued/Re*ed: 03/28/11 SHEET 1 OF 2 buramax 62168 PLA MHEEL FOR 31/2"O.D. POST TYPICAL ASSEMBLY POST(SOLD TYPICAL 318" SEPARATELY) HEAVY HEX NUT �r 1/4"x314" � DRIVE RIVET (1 68W449)TYP. ci 3 112"0.D- HALF 12"O.D_HALF CLAMP ' STEERING \ J WHEEL 114 x 112' DRIVE RIVET (805301)TYP. TYPICAL 1117 P.B.H.C.S.w/PATCH wl 3i8"FIAT WASHER Issued/Raised: 03/28/11 SHEET 2 OF 2 buramax 62243 Leg Lift PARTS LIST No. I PART DESCRIPTION REQ`D NUMBER Leo Lift Bracket t 305626 31/2"O.D.Haff Clamp 1 _� 301765 Hantmr+e to 1 1 305629 1l4"x 314"Drive Rivet ? 1 168+149• 3/8'Fiat Washer _ _ 2 817410' 318'x/ 114°P.B.H.C.S.w/Patch 2 812051' 318'Heavy Hex Nut 2 1 804200` Unless Otherwise SpecNled,An Units of Measure are Each 'Included In Hardware Warning.Small parts and hardware Items may present a potential choking hazard. Promptly remove all unused parts from play area. Any bolt end protruding more than two full threads beyond the face of the nut causes risk of clothing entanglement Promptly cut-off Bush, file smooth,and treat to prevent corrosion. Note:Peen Tee-Nuts and Flatwashers to match radius of pipe after assembly Is compleft Note:Loctite(supplied by others)should be used on any non-patch hardware. INSTALLATION INSTRUCTIONS: 1.Attach the Leg Lift to Up-Right Post at the designed location using Half Clamp,3/8'x 1 1/4"P.B.H.C.S.w/Patch,3/8'Fiat Washers and 3/8"Heavy Hex Nuts as shown In the assembly diagram.(Note that 60"height can be adjusted up or down depending on Intended age group.) 2.When the assembly Is finished and satisfactory,instal Drive Rivets In all damps to ensure damps cannot slide down posts. See Clamp subassembly sheet. It is very important that all Drive Rivets be Installed before allowing use of the equipment as clamps are not designed to support substantial welght without them.Also eliminate sharp points and sharp edges(burring)on Installed hardware Oke bolts,nuts,etc. Install resilient surfacing material within the use zone of play structure in accordance with ASTM specifications F1292 appropriate for the fall height of each structure. Refer to the Safety Guidelines. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and tighten as necessary.Always check all parts for breakage or wear,and Immediately put equipment out of service until any faulty parts found are repaired or replaced. Also Check all metal parts for rust, paint loss and touch-up If necessary with paint.Check for welded areas and verify Integrity.Check periodically resilient surfacing for appropriate depth and remove extraneous materials that could cause injury,Infection,or disease.Maintain detailed Installation,inspection, maintenance,and repair records for each public-use playground equipment. Issued/Revised: 03/15/13 SHEET 1 OF 4 buramax 62243 Leg Lift r� l l l I l I 31n•O.D.HALF l I CLAMP LEG LIFT BRACKET I l l ( l I l I ( l l l I I l I 3 1/2"O.D.UPRIGHT POST l (SOLD SEPARATELY) l l l l l l I l FINISHED ASSEMBLY IssuedlRevised: 03115/13 SHEET 2 OF 4 buramax 62243 Leg Lift I I I I i I I ! { I l I I I I I I I i I 60"[1524mm] I I ( I ( I ( I I I I I I I I I I I I i I _ RESILIENT SURFACING I I MIN.10"[254mm) I i 30"[762mml L'j. 18"[457mml DIAMETER ELEVATION VIEW IssuedlRevised: 03/15113 SHEET 3 OF 4 buramax 62243 Leg Lift 318"HEAVY HEX NUT 1/4"x 314"DRIVE r \ (804200) RIVET(168449) 1 ~ —' I 1 I I 1 ( � I� 318"FLAT WASHER (817410) I I i I I I I 3/8"x 1 1/4"P.B.H.C.S. 1 I W/PATCH(812051) I 1 I I ( ( I I I 1 ( f I 1 1 i I l I 1 1 1 I 1 I 1 I i I LEG LIFT ASSEMBLY Issued/Revised: 03/15/13 SHEET 4 OF 4 Duramax 62267 LOOP POLE (34"t DECK) Parts List DESCRIPTION QTY PART NUMBER ENTRY ARCHWAY WITH SOCKET 1 313655 LOOP POLE 1 306143 3 1/2'O.D.DECK CLAMP 2 301731 HARDWARE COMPLETE 1 306116 3/8"x 1"P.B.H.C.S.w/PATCH 2 812050 3/8"x 1 1/2"P.B.H.C.S.w/PATCH 5 812053 3/8"FLAT WASHER 3 817410 3/8'FLAT WASHER(1 1/4'O.D.) 4 817424 3/8'LOCK NUT 2 804353 3/8"BARREL NUT 3 804804 318"HEAVY HEX NUT 2 804200 1/4"x 3/4'DRIVE RIVET 2 168449 Unless Otherwise Specified.All Units of Measure are Each 'Items listed below Hardware Complete line are included with Hardware Complete Number Warning:During Installation,Hardware And Small Parts Are Choking Hazards For Young Children.Store Unused Parts Appropriately Until Assembly is Completed.Once Assembly is Completed,Remove Any Unused Parts From The Play Environment And Dispose/Save Them In A Secure Location.Any bolt end protruding more then two full threads beyond the face of the nut causes risk of clothing entanglement. Promptly cut-off flush,file smooth,and treat to prevent corrosion. Note:Peen Tee-Nuts and Fiatwashers to match radius of pipe after assembly is complete. Note.Loctite(supplied by others)should be used on any non-patch hardware. INSTALLATION INSTRUCTIONS: 1. Determine which Deck is to receive the Loop Pole_Refer to your Top View drawing for location_ 2. Dig footing holes for Loop Pole$Posts at locations noted on Top View. 3. Using a 7/16'drill bit,ream out any excess'Plastisol'coating from all holes used on the Deck.Be careful not to expose the steel. 4. Using Detail-001 and Elevation View,locate and fasten two Deck Clamps to Upright Posts using 3/8'x 1-112"P.B.H.C.S. w/Patch.and 3/8'Heavy Hex Nut. 5. Using Detail-797,attach Entry Amway to Upright Posts using Deck Clamps and fasten with 3/8'x 1-1/2'P.B.H.C.S w/Patch,3/8"Flat Washer,and 3/8"Barrel Nut. 6. Using Detail-026,insert Entry Archway tab through slot on top of Deck and fasten to flange using 318"x 1"P.B.H.C.S. w/Patch,3/8"Flat Washer(1-1/4"O.D.),and 3/8"Lock Nut. IMPORTANT! Avoid creating any gaps between the components which fall between 3-1/2"and 9". it has been shown that such gaps create entrapment points which can trap a child and cause injury. lssuedlRevised: 12/21/2015 SHEET 1 OF 5 Duramax 62267 LOOP POLE (3141' DECK) 7. Place Loop Pale Into dug hole and attach the swaged end to the socket on top of the Entry Archway using 3/8"x 1 1/2" P.B.H.C.S w/Patch,318"Flat Washer,and 3/8"Barrel Nut as shown in Detail-066. 8, Plumb and levet the entire assembly and tighten all fasteners. 9. Pour concrete footings within 4"to the top and taper away from posts for water drainage.Allow to cure at least 48 hours before use. % When the structure is finished and satisfactory,install Drive Rivets in all clamps to ensure clamps cannot slide dawn posts. See Ring Clamp subassembly sheets. It is very Important that alt Drive Rlvets be Installed Amor to allowing use of the eVipment, as clamps are not deslaned to support substantial welaht without them. Install resilient surfacing material within the use zone of play structure in accordance with ASTM specifications F1292 appropriate for the fall height of each structure. Refer to the Safety Guidelines. Eliminate sharp points and sharp edges(burring)on installed hardware like bolts,nuts,etc. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and tighten as necessary.Always check all parts for breakage or wear,and immediately put equipment out of service until any faulty parts found are repaired or replaced.Also Check all metal parts for rust,paint loss and touch-up if necessary with paint.Check for welded areas and verify Integrity.Check periodically resilient surfacing for appropriate depth and remove extraneous materials that could cause injury,infection,or disease.Maintain detailed installation,Inspection, maintenance,and repair records for each public-use playground equipment. lssued(Revised: 12/2112015 SHEET 2 OF 5 buramax 62267 LOOP POLE (3'4" DECK) R ENTRY ARCHWAY WITH SOCKET(313655 X797 (;001;: ! LOOP(3361�� ( I CLAMP(3017 1) ( 1 ( GAP BETWEEN UPRIGHT I AND ENTRY ARCHWAY 1. SHALL BE LESS THAN 3 112" I � 026 ! 1 it ( it II LJ FINISHED ASSEMBLY COMPONENTS SHOWN IN HIDDEN LINES ARE SOLD SEPARATELY a =INSTALLATION DETAIL Issued/Revised: 12/21/2015 SHEET 3 OF 5 Duramax 62267 LOOP POLE (34" DECK) 36 in 191.44 c►n] 018 in [45.72 cm] `� \ REF. t "f t 19 112 in [49.45 cm] 014 in 18 in [35.56 cm] [45.72 cm] PLAN VIEW CONCRETE REQUIRED 0.07 CUBIC YARDS (0.05 CUBIC METERS) 3 in (7.69 cm] HOLD I I I 39 5/8 in 1100.59 cm] I I I I 103 1/4 in 1262.25 cm] li II I � � I 40 in ( I I [101.60 cm] loin I I ( I [25.40 cm] II li RESILIENT SURFACE 30 in I, til I; I•�" I ( [76.20 cm] I • •I I� ,�'1 I�� ( � -i •' •I ql� J L aL BRICK OR EQUIVALENT ELEVATION VIEW IssuedJRevised 12/21/2015 SHEET 4 OF 5 INCH 1111. 11 If III IT 11 1111f 111111111111111111111 1 111 fill 11111111111111111111111 11111filill OCM 1 2 3 4 5 B 7 8 9 10 11 12 13 14 15 62267 LOOP POLE (3'4" DECK) COMPONENT UPRIGHT POST 318"HEAVY HEX NUT (804200) DECK CLAMP I DECK 318 x 1"P.B.H.C.S. w/PATCH(812050) • DRILL USING 1/4"DRILL BIT TO RECEIVE DRIVE RIVET V 3/8"x 1/2" 3!8"FLWAS ER 318"L CK NUT A 1/4"x 314" RIVE P.B.H.C.S.w/PATCH (1 i/4" A0. (817424) (804353) RIVET(168449) (812053) 00i') 026 318'x 1 1/2" P.B.H.C.S.w/PATCH (812053 NOTE: BEND THE WASHER TO 3/8"FLAT WASHER MATCH THE CURVATURE OF 817410) THE OVERHEAD EXTENSION PIPE 318"x 1 1/2" P.B.H.C.S.w/PATCH (812053 ENCLOSURE 3/8"FLAT WASHER (817410) } CLAMP 1 SWAGED PIPE PIPE 3/8"BARRE NUT (804804) 066 318"BARREL N T (80480-0) .797j Issued/Revised: 12121/2015 SHEET 5 OF 5 � \ « �S : § ° � ) d �: �G�\ �d z �����_ ��_���_ : d d �_ ` w : w > ���� } : e « a « a � > _ , r : § > � a ' _ : � : w m : > . : . + � � � } ° < � � ( ( ( � ( � ® . � � _ / , « d : : . , y , : y = ( . g< ( : < : : z : � : _ �® : r : � , : ! . , � � \ ^ \ buramax 62345 RETURN STEP PARTS LIST No. PART DESCRIPTION REQU NUMBER Return Step, 1 308825 Small Kick Plate 1 305741 _ Support Plpe_ � _ 2 _ 168470 Hardware Co lets 1 307321 318`Lock Nut 4 804353' 318"Tea Nut 2 804556` 3/8"x 1"P.B.H.C.S.w/Patch 4 812050` 318"x 1314"P.B.H.C.S.w/Patch 2 812054' 31W Lock Washer 2 817334' 3/8"Flat Washer 1 f4"­6.13.) 10 817424` Unless Otherwise Speclfled,All Units of Measure are Each 'Included In Hardware Warning:Small parts and hardware Items may present a potential choking hazard. Promptly remove all unused parts from play area. Any bolt end protruding more than two full threads beyond the face of the nut causes risk of clothing entanglement. Promptly cut-off flush,file smooth,and treat to prevent corrosion. Note:Peen Tee-Nuts and Pletwashers to match radius ofp*after assembly is complete. Note:Loctite(supplied by others)should be used on any non-patch hardware. INSTALLA77ON INSTRUCTIONS: 1.Locate the Triangle Transfer Point to attach the Return Step. 2.Dig Holes to receive the Support Pipes according to dimensions shown In Plan View.Footing Dimension Is specified In Elevation View. 3.Attach the Small Kick Plate to the Modular Platform using 3/8"x 1"P.13,1-I.C.S.w/Patch,3/8"Flat Washer(1 1W O.D.)and 318"Lock Nut as shown In Detail 106.Note that the Small Fick Plate receded area goes on top and attaches behind deck or platform. 4.Attach the Return Step to the lower part of Small Kick Plate using the same hardware and Detail as In step 3.(Detail 106) S.Attach the Support Pipes to the lower slats on the sides of the Return Step with 3/8'x 1314"P.B.H.C.S. w/Patch,318"lock Washer,318"Rat Washer(1 '/,"O.D.),and 318'Tee Nut.See Detail 124. 6.Plumb and level the entire assembly.Pour concrete footings within 4"to the top and taper away from supports to allow drainage.Alow to cure at least 48 hours before use. 7.Eliminate sharp points and sharp edges(burring)on installed hardware like bolts, nuts etc.Install resilient surfacing material within the use zone of play structure In accordance with ASTM specifications F1292 appropriate for the fall height of each structure.Refer to the Safety Guidelines. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and lighten as necessary,also check If the entrapments and protrusions still satisfactory.Always check all metal parts for paint peeling,corrosion and touch up if necessary.Check all parts for crack, breakage or wear,and Immediately put equipment out of service until any faulty parts found are repaired or replaced.Check pertodlcally resilient surfacing for appropriate depth and remove extraneous materials that could cause Injury,Infection,or disease.Maintain detailed installation,inspection,maintenance,and repair records for each public use playground equipment Issued/Revised: 03/11111 SHEET 1 OF 4 buramax 62345 RETURN STEP TRIANGULAR TRANSFER AND HANDHOLD SOLD SEPARATELY SMALL KICK PLATE � � { (305741) 106 r( 'r II I i { { I I U ! I ( I U TRANSFER STEP (308$25) SUPPORT PIPE 124 (168470) FINISHED ASSEMBLY Q-INSTALLATION DETAIL Issued/Revised: 03/11/11 SHEET 2 OF 4 buramax 62345 RETURN 5 TEP �� �� 1(]°000°000000 00°000° N- 0 0000000 0000 ( O 00000000 000 19 3/16"[487mm] I000000000 00 0000000000 0 000000000 00 1 0000�0q0°00 00p 000°oo°Qgo°o�Q 08 ° o° 38 5/16"[974mm] ' 080000 O0pp°o p O 0000 p�00 p0 0 Qo0° 0p0�0 00000 OOD Po 0 p00 O � O 0°O °00 f 014"[0356mm] 19 118"[486mm] (3 PLCS) 38 5116"[973mm] PLAN VIEW CONCRETE REQUIRED: .20 CUBIC YARDS [.15 CUBIC METERS] III I I 16'[406mm] 8"[203mm] 10"(254mm)MIN. 111 I I III ( ( I I RESILIENT SURFACE 30"[762mm] III I • ``' `t W LJ ... 1 14"[356mm] -`I DIA.TYP. ELEVATION VIEW Issued/Revised: 03/11111 SHEET 3 OF 4 0INCH 1 2 3 4 5 6 111JI1,111,11111dil, f, �,�,I, �,�,(,►,�, �, �,►,�,�,�, I,I��,I,�I��11,I,I��,I,I�I�11IJ 11111111 1111111,111,11 It'll 1111 It 111111 111111 1111111111111114111 111111111 T 111111111....I....i,mFT9m7 OCM 1 2 3 4 5 8 7 8 9 10 11 12 13 14 15 62345 RETURN STEP 318"LOCKNUT TOP DECK PLATFORM (804353) 3/8"T-NUT (8040 W FLATWASHER i (817424)(1 114'O,D.) 318"LOCKWASHER r (817334) SUPPORT J RUNG 3/8"x 1"P.B.H.C.S. 318'x 1 3/4"P.B.H.C.S. KICKPLATE w/PATCH(812050) w/PATCH(8 12054) 3/8'FLATWASHER (1 114`O.D.)(817424) 706 124 Issued/Re*ed: 03/11/11 SHEET 4 OF 4 Duramax 62348 Triangle Transfer Point (2`-8') Parts List ITEM DESCRIPTION 62348 62349 62350 PART NUMBER 1 ATTACHMENT RAIL 2 2 2 312705 2 STAIRS(1'-4'RISE) 1 0 0 307252 2 STAIRS(2'-(r RISE) 0 1 0 307274 2 STAIRS(2'-8"RISE) 0 0 1 307281 3 HANDRAIL 2 0 0 312656 3 HANDRAIL 0 2 0 312659 3 HANDRAIL 0 0 2 312662 4 PLATFORM 1 1 1 309853 5 UPRIGHT ASSY 1 1 1 160562 6 HANDHOLD 1 1 1 306838 3 1/2"O.D.DECK CLAMP 2 2 2 301731 —HARDWARE COMPLETE— 1 1 1 312708 1/4"x 3/4"DRIVE RIVET 2 2 2 168449 3/8" HEAVY HEX NUT 2 2 2 804200 318"LOCK NUT 4 4 4 804353 318"BARREL NUT 2 2 2 804804 3/8"x 314"P.B.H.C.S.wIPATCH 3 3 3 812052 3/8"x 1'P_B.H.C.S.wlPATCH 2 2 2 812050 3/8"x 1 1/4"P.B.H.C.S.w/PATCH 2 2 2 812051 3/8"x 1 112"P.B.H.C.S.-/PATCH 4 4 4 812053 3/8"x 1 3/4"P.B.H.C.S.w/PATCH 4 4 4 812054 3/8"x 2 114"P.B.H.C.S.w/PATCH 1 1 1 812056 3/8"x 2 112"P.B.H.C.S.w/PATCH 4 4 4 812057 3/8"LOCKWASHER 12 12 12 817334 3/8"FLAT WASHER 2 2 2 817410 318"FLAT WASHER(1 1/4"O.D.) 8 8 8 817424 318"T-NUT 12 1 12 1 12 804556 112"FLAT WASHER 4 1 4 1 4 817412 Unless Otherwise Specified,Ail Units of Measure are Each Items listed below Hardware Complete line are included with Hardware Complete Number Warning.During Installation,Hardware And Small Paris Are Choking Hazards For Young Children.Store Unused Parts Appropriately Until Assembly Is Completed.Once Assembly Is Completed,Remove Any Unused Parts From The Play Environment And 01spose/Save Them in A Secure Location.Any bolt end protruding more than two full threads beyond the face of the nut causes risk of clothing entanglement Promptly cut-of flush,R/e smooth,and treat to prevent corrosion. Note.Peen Tee-Nuts and Flatwashers to match radius of pipe after assembly Is complete. Note:Loctite(supplied by other)should be used on any non-patch hardware. INSTALLATION INSTRUCTIONS: 1.Determine wNch deck is to receive the Transfer Module,refer to your overhead drawing for location.Dig footing holes at location and depth shown. lssued[Revised: 10/3/2013 SHEET 1 OF 6 Duramax 62348 Triangle Transfer Paint (2'-8') 2. Loosely attach 3 112'O.Q. Deck Clamp to Uprights at noted height using Detail 001.Fasten Attachment Rails to the clamp as shown in Detail 043. 3.Attach Upright Assembly to underside of Platform using 3/8'x 3/4"P.B.H.C.S.wfPatch,3/8"Lock Washer,and 3/8"T-Nuts as shorn in Detail 247.Connect Smashed Pipes to bottom edge of the Platform Step using 3/B"x 1"P.B.H.C.S.w/Patch,3/8"Flat Washers(1 114"O.Q.)and 3/8"Lock Nuts as shown in Detail 554. 4.Attach the Handhold to side of the Platform using 318'x 2 114"P.B.H.0 S_ w/Patch,3/8"Lock Washers and 3/8"T-Nuts as shown in Detail 125. 5.Position assembly In dug holes and match holes in Stairs to holes in deck and Platform and fasten as shown in Detail 147 at the deck and Detail 600 at the Platform. 6.Then, placing Handrails into dug holes, Attach Handrails to side of steps using 3/8"x 1 3/4"P.B.H.C.S.w/Petch,3/8"Lock Washers, 112"Flat Washers, and 318'T-Nuts as shown in Detail 599 and attach to Attachment rails using 318"x 2 1/2" P.B.H.C.S. w/Patch,3/8'Lock Washers, 112"Flat Washers,and 318"T-Nuts as shown in Detail 145. 7-When the entire assembly is plumb and level,tighten all fasteners and pour concrete footings within 4"to the top and taper away from support posts to allow water drainage. Allow to cure at least 48 hours before use. IMPORTANTI Avoid creating any gaps between the components which fall between 3-112"and 9". It has been shown that such gaps create entrapment points which can trap a child and cause Injury. When the structure is finished and satisfactory,install Drive Rivets in all clamps to ensure clamps cannot slide down posts.See Ring Clamp subassembly sheets.h is very Important that all Drive Rivets be Installed prior to allowing use of the equipment:as clamps are not designed to support substantial weight without them. Install resilient surfacing material within the use zone of play structure in accordance with ASTM specifications F1292 appropriate for the fall height of each structure. Refer to the Safety Guidelines. Eliminate sharp points and sharp edges(burring)on installed hardware like bolts,nuts.etc. Note:To cushion accidental falls by children,Park Structures strongly recommends that the area under and around the play structure must be covered with a resilient material,such as sand,mulch,etc.,to a minimum depth of 10"for sand. Approved rubber safety matting can also be used.For details,please refer to your Safety Guidelines,provided within the assembly instruction packet. MAINTENANCE PROCEDURE. Periodically check hardware for tightness,and tighten as necessary. Always check parts for breakage or wear.and immediately put equipment out of service until any faulty parts are repaired or replaced. Check for rust,paint loss,and touch up if necessary with paint. Check for welded areas and verify integrity. Check all decks for peeling of Plastisol coating and touch up with Piastisol if necessary. Check for obstructed holes on deck,clean if necessary. Check for openings on plastic junctions and use clear silicone to fill. Check for cracks,gouges,or breakage on plastic. Check for integrity of plastic and keep plastic keep of any extraneous substances. Verify that any deformation does not create entrapment as specified on ASTM F1487 section B. Periodically check resilient surfacing for appropriate depth,and remove extraneous materials that could cause injury,infection,or disease. Maintain detailed installation,inspection,maintenance,and repair records for each public-use playground equipment Issued/Revised: 10/3/2013 SHEET 2 OF 6 Duramax 62348 Triangle Transfer Point (2'--8') 043 001 I I 1 145 I I ( I 3 I I ( 147 I 2 I I iy 4 600 I ( I II II II II LJ 599 125 5 247 UNDERNEATH FINISHED ASSEMBLY 62349 SHOWN O =INSTALLATION DETAIL Issued/Revised 10/3/2013 SHEET 3 OF 6 Duramax 62348 Triangle Transfer Point (2'-8') 36 in [91.44 cm] 14-11 26 3/4 n .8. (67.92 cm] PLAN VIEW � •c- 37 1/8 in (94.23 cm) 14 9118 in ..�„ 078 in (37.06 cmi 4 5/8 in [45.72 cm] [11.76 cm] 014 in 21 1/16 in (53.42 cm) [35.56 cm) 5 PLCS. 281/2 in (67.37 cm] Dimension Table Product Deck Height Dim.A Dim.B Dim.C 62348 32 in an 49 5/8 in(126.05 cm 12 1/2 in 31.67 art 27 1/8 in 68.89 cm 62349 40 in cm 64 5/16 [163.37 cm 27 3/16 in[68.99 cm] 41 13/16 in[106.21 cm] 62350 48 In 121.92 cmT 79 in[200.6F—cm—j- 41 11116 in 106.27 an 56 1 In 143.52 cm fi fi ( ) 40 1/2 in I I [102.87 cm] II II ELEVATION VIEW I ( I I DECK HEIGHT I —� RESILIENT SURFACE 30 in ,. [78.20 cm] 10 in "{ 125.40 cm] MIN. Issued/Revised: 10/3/2013 SHEET 4 of 6 INCH d,1. I. �I.1�J� 111111111111,toil,14111111111 Ip I I;III ,III 1111111111111 1111111111111111 111IM1111111 1111111 If I I I III III T I I If 1"1111i T It 11111111111111111111117 0cm 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 62348 Triangle Transfer Point (2'--8') UPRIGHT 3/8"LOCK NUT 3/8"HEAVY HEX NUT POST (804353) 3/8"FLAT WASHER (804200) (1 114"0.D.)(817424) DECK CLAMP 3/8"FLAT WASHER (1 1/4"O.D.)(817424) DRILL USING 1/4"DRILL BET TO RECEIVE DRIVE RIVET PLATFORM 1/4"x 3/4" IVE RIVET(168449) 318"x 1"P.B.H.C.S. _ W/PATCH(812050) 1 m t r• 600'1 318"LOCKWASHER 3/8"T—NUT(804556) (817 34) 3/8"T—NUT(804556) 3/8"LOCKWASHER (817334) 318"x 2 1/2" P.B_H.C.S.W/PATCH (812057) n. HANDRAIL 1 1� IssuedlRevised: 10/3/2013 SHEET 5 OF 6 Q INCH i1 i � i � 1 i 11JI i 1 I,►,�,►� ,►,�,►, .1,1.1, .1,�.I' lI.111, ,1,1,1 , ,�,I, ,1,x,1, ,►,�,1, 11��11 ►.I,I. ,1,1,►, 111m,1111iII111111 111 14 0cm 1 2 3 4 5 6 7 8 8 10 11 i2 13 14 15 62348 Triangle Transfer Point (2`--8') 318'LOCK NUT 3/8"FLAT WASHER (804353) 17410) 3/8"FLAT WASHER (1 1/4"0.D,)(817424) ENCLOSURE 3/8"FLAT WASHER (1 114"O.D. (817424 DECK PLATE DECK CLAMP 318"x 1 1/4' P.B.H.C_S.w1PATCH (812051) STAIRS F318"BARREL NUT 147 804804) 1_ ,i 318"T-NUT(804556) 3/8"T-NUT(804556) HANDHOLD PLATFORM 318'LOCKWASHER PLATFORM (817334) SUPPORT PLATFORM 3/8"LOCKWAS ER (817334) 318"x 2 /4' P.B.H.C.S.wIPATCH 3/8x3/4"P. .H.C.S. (812056) w/PATCH(812052) (;247; �125;r Issued/Revised: 10/3/2013 SHEET 6 OF 6 Duramax 63923 COIL CLIMBER (4#8" DECK) Parts List DESCRIPTION QTY PART NUMBER ENTRY ARCHWAY WITH SOCKET 1 313655 COIL CLIMBER 1 306128 3 1/2'0.D.DECK CLAMP 2 301731 HARDWARE COMPLETE 1 307159 3/8"x 1'P.B.H.C.S.w/PATCH 2 812050 3/8"x 1 11/2"P.B.H.C.S.wlPATCH 5 812053 318"FLAT WASHER 3 817410 318"FLAT WASHER(1 114"O.D.) 4 817424 31W LOCK NUT 2 804353 3/8"BARREL NUT 3 804804 3/8"HEAVY HEX NUT 2 804200 1/4"x 314"DRIVE RIVET 2 168449 112"ANCHOR ROD 1 135038 Unless Otherwise Specified,All Units of Measure are Each 'Items listed below Hardware Complete fine are included with Hardware Complete Number Warning:During Installation,Hardware And Small Parts Are Choking Hazards For Young Children.Store Unused Parts Appropriately Until Assembly/s Completed.Once Assembly/s Compfated,Remove Any Unused Parts From The Play EnvlronmentAnd DlsposelSave Them In A Secure Locadon.Any bolt and protruding more than two full threads beyond the face of the nut causes risk of clothing entanglement Promptly cut-of Rush,file smooth,and treat to prevent corms/on. Note:Peen Tee-Nuts and F►etwashers to match radius of pipe aRerassembly Is complete. Note:Loctite(supplied by others)should be used on any non-patch hardware. INSTALLATION INSTRUCTIONS: 1. Determine which Deck is to receive the Coil Climber.Refer to your Top View drawing for location. 2. Dig footing holes for Coll Climber&Posts at locations noted on Top View. 3. Using a 7116"drill bit,ream out any excess"Plastisol"coating from all holes used on the Deck.Be careful not to expose the steel. 4. Using Detail-001 and Elevation View,locate and fasten two Deck Clamps to Upright Posts using 3/8'x 1-112"P.B.H.C.S. w/Patch,and 318"Heavy Hex Nut. 5. Using Detail-797,attach Entry Archway to Upright Posts using Deck Clamps and fasten with 318"x 1-1/2"P-B.N.C_S w/Patch,3/8"Flat Washer,and 3/8"Barrel Nut. 6. Using Detail-026,Insert Entry Archway tab through slot on top of Deck and fasten to flange using 3/8"x 1"P.B.H.C.S. w/Patch,3/8"Flat Washer(1-1/4"O.D.),and 318"lock Nut. IMPORTANT! Avoid creating any gaps between the components which fall between 3-1/2"and 9". It has been shown that such gaps create entrapment points which can trap a child and cause Injury. Issued/Revised: 12/14/2015 SHEET 1 OF 5 Quramax 63923 COIL CLIMBER (4'8" DECK) 7. Insert Anchor Rod into hole in bottom of Coil Climber and place It Into dug hole.Attach swaged end of Coil Climber to Entry Archway with 3/8"x 1 112"P.B.H.C.S w/Patch,318"Flat Washer,and 318"Barrel Nut as shown in DetatW66. 8. Plumb and level the entire assembly and tighten all fasteners. 8. Pour concrete footings within 4"to the top and taper away from posts for water drainage.Allow to cure at least 48 hours before use. 10. When the structure is finished and satisfactory,install Drive Rivets in all clamps to ensure clamps cannot slide down posts. See Ring Clamp subassembly sheets.It Is very important that aN Drive Rivets be Installed prior to allowing use of the equipment, as clamps are not designed to support substantial weight wHhout them. Install resilient surfacing material within the use zone of play structure in accordance with ASTM specifications F1292 appropriate for the fail height of each structure. Refer to the Safety Guidelines. Eliminate sharp points and sharp edges(butting)on installed hardware like bolts, nuts,etc. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and tighten as necessary.Always check all parts for breakage or wear,and immediately put equipment out of service until any faulty parts found are repaired or replaced.Also Check all metal parts for rust,paint loss and touch-up if necessary with paint.Check forwetded areas and verify integrity. Check periodically resilient surfacing for appropriate depth and remove extraneous materials that could cause injury,infection,or disease.Maintain detailed installation,inspection. maintenance,and repair records for each public-use playground equipment. lssued/Re*,ed: 12/14/2015 SHEET 2 OF 5 buramax 63923 COIL CLIMBER (4`8" DECK) ENTRY ARCHWAY WITH SOCKET(313655) f^ 797; r 'OQ1 I I 112'O.D.DECK CLAMP(301731) I ) 11 I GAP BETWEEN UPRIGHT COIL CLIMBER i �`�r AND ENTRY ARCHWAY (306128) I I �JJ SHALL BE LESS THAN 3 1/2" \� r o2s_ II II II II II II II II lJ FINISHED ASSEMBLY COMPONENTS SHOWN IN HIDDEN LINES ARE SOLD SEPARATELY 0 =INSTALLATION DETAIL Issued[Revised 12/14/2015 SHEET 3 OF 5 Duratmax 63923 COIL CLIMBER (4`S" DECK) 36 in "[91.44 cm] 018 in I��1 [45.72 cm) REF. 1 19 12 in [49.45 cm] 014 in lain [35.56 cm) [45.72 cm) PLAN VIEW CONCRETE REQUIRED 0.07 CUBIC YARDS — [0.05 CUBIC METERS] Fi fi 3 In [7.69 cm]' 39 5/8 in HOLD I I [100.59 cm] 118 114 in [302.89 cm] I ) ( i 56 in [142.24 cm) I I I 10 In [25.40 cm] RESILIENT SURFACE 30 in [76.20 cm) , 6, 1 L AL'J ANCHOR ROD BRICK OR EQUIVALENT ELEVATION VIEW Issued[Revised 12114/2015 SHEET 4 OF 5 q INCH 1ilt1,X11, ,1,�,1,�,f,�,�,�,1,l,�,l,i,�,�,1,1111111,1,1,1,I'll I.I.1.1.1,1,1.1.1.1.1.1.1,1.IJ OCM 1 2 3 4 5 6 7 8 9 10 11 112 13 14 15 63923 COIL CLIMBER (418" DECK) UPRIGHT COMPONENT POST 318"HEAVY HEX NUT (804200) DECK CLAMP DECK 3/8"x 1"P.B.H.C.S. w/PATCH (812050) DRILL USING f • 1/4"DRILL BIT TO RECEIVE M DRIVE RIVET 4kL 318"x 1/2* 1/4"x 314" RIVE P.B.H.C.S.w/PATCH 3/8"FLA WAS ERV 3/8'L CK NUT RIVET(188449) (812053) (1 1/4"O.O.)(817424) ,," ��, (804353) '001 ; 3/8"x 1 1/2' P.B.H.C.S.w/PATCH (812053 NOTE: BEND THE WASHER TO 3/8"FLAT WASHER MATCH THE CURVATURE OF 817410) THE OVERHEAD EXTENSION PIPE 31W x 1 112" P.B.H.C.S.w/PATCH ENCLOSURE(812053 3/8"FLAT WASHER (817410) CLAMP t SWAGED !) PIPE PIPE O 3/8"BARRE NUT (804804) j -, 3/8"BARREL N T (804804) :797; IssuedlRevised 12/14/2015 SHEET 5 OF 5 t { 1Al VI bj buramax 63994 Bench Seat PARTS LIST No. PART DESCRIPTION REal) ! NUMBER Plastic Panel Seat for two 1 302366 1 518'O.D.Seat Support Beam 1 303237 3 1/2'O.D.Half Clamp 2 301765 Hardware Complete 1 ( 306918 114"x 3i4'Drive Rivet 2 168449' 318"Barrel Ntd 4 844804 318'Flat Washer 12 817410' 3/8"Heavy Hex Nut 4 804200' 318'x 1 112"P._B.H.C.S w/Patch � 4 _ 812-05-3- 3/8 x 112 P.B.H.C.S w1 Patch 1 4 812049' Unless Otherwise Specified,All Units of 1lleasure are Each "Included in Hardware Warning:Small parts and hardware items may present a potential choking hazard. Promptly remove all unused parts from play area. Any bolt end protruding more than two full threads beyond the face of the nut causes risk ofctothing entanglement. Promptly cut-off flush,file smooth,and treat to prevent corrosion. !Vote:Peen Tee-Nuts and Fletwashers to match radius of pipe after assembly Is complete. Note:Loctite(supplied by others)should be used on all threaded hardware. INSTALLATION INSTRUCTIONS: 1.Locate,measure,and dig footings for uprights. Refer to your overhead drawings for correct locations. 2,Using Detail 121 attach Seat Panel to Seat Support Beam with 318"x 1/2'P.B,H,C.S.w/Patch(812052),3/8'Fiat Washer (812052),and 3/8"Barrel Nut(804804). NOTE:Counterbored holes to receive Barrel Nut 3.Using Detail 122 attach assembled Seat to Half Clamps with 3/8"x 1-112"P.B.H.C.S.w/Patch(812053),318' Rat Washer (812052),and 318"Heavy Hex Nut(804200). Refer to Elevation View for correct height of clamps. 4.Plumb and level the entire assembly and tighten all fasteners. 5.Pour concrete footings within 4"to the top and taper away from posts for water drainage.Allow to cure at least 48 hours before use. 6.When the structure Is finished and satisfactory,install 114"x 3/4'Drive Rivets in all Clamps to ensure Clamps cannot slide down posts,referring to Typ. Clamp Detail.Eliminate sharp points and sharp edges(burring)on Installed hardware tike bolts, nuts etc.it is vatic!Important that all Drive Rivets be installed prior to allowing use of equipment,as clamps are not designed to support substantial welg►ht without them. Install resilient surfacing material within the use zone of play structure In accordance with ASTM specifications F1292 appropriate for the fall height of each structure.Refer to the Safety Guidelines. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and tighten as necessary.Always check parts for breakage or wear,and immediately put equipment out of service until any faulty parts are repaired or replaced.Check for rust,paint loss,and touch up If necessary with paint Check for openings on plastic junctions and use clear siilcone to fill.Check for cracks,gouges,or breakage on plastic. Check for Integrity of plastic and keep plastic keep of any extraneous substances.Verify that any deformation does not create entrapment as specified on ASTM F1487 section 6.Periodically check resilient surfacing for appropriate depth,and remove extraneous materials that could cause injury,infection,or disease.Maintain detailed installation,inspection,maintenance,and repair records for each pubtlo-use playground structure. IssuedRevised: 04/14111 SHEET 1 OF 4 buramax 63994 Bench Seat 3112"UPRIGHTS SOLD SEPARATELY 121 e 0 ¢ 3 1/2'O.D.HALF CLAMP(301765) SEAT PANEL (302366) 122 SEAT SUPPORT BEAM(303237) FINISHED ASSEMBLY O =INSTALLATION DETAIL Issued/Revised: 04/14/11 SHEET 2 OF 4 buramax 53994 Bench Seat 36"[914mm] PLAN WEW \ ) o o \ ELEVATION VIEW 13"[330mm] f 1 I I f RESILIENT SURFACE f I MIN.10*[254mm] I ( f I 30"(762mm] • + eI f � f � _ d-I I •a• � d f I a f i �I i• •f f• I7� L J i dL Ji L L� -°! — J 14"[355mm] DIAMETER I-- REF. Issued/Revis : 04/14/11 SHEET 3 OF 4 0INCH 1 23 f 4 5 ii 6 tltitlt1tlt1t'111111{,1tItitl11t{t1t1lltlt1tltl1l11tlt11111,111 111 ll It 111 0CM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 63994 Bench Seat 318"x 1 112"P.B.H.C.S. 318"BARREL w/PATCH(812053) NUT(804804) SEAT PANEL 114"x 314"DRIVE RIVET(168449) 3/8"FLATWASHER 3/8'FLATWASHER p.� (817410) 1 (817410) HALF 318"HEAVY HEX CLAMP SUPPORT NUT(804200) BEAM X21 3!8'FLATWASHER �Q2 318'X 112"P.B.H.C.S. (817410) w/PATCH(812049) NsuedAevised: 04/14/11 SHEET 4 OF 4 buramax 63995 CURVY CANOPY PARTS LIST No. PART DESCRIPTION REQ D NUMBER Curvy Canopy 1 306928 Hardware Com tete 1 302069 #14 x 3"Self-q#ging Screw 4 809698` 114'Washer 4 817408• Unless Otherwise Specified,All Unita of Measure are Each 'Included In Hardware Warning:Small parts and hardware items may present a potential choking hazard. Promptly remove all unused parts from play area. Any bott and protruding more than two full threads beyond the face of the nut causes risk of clothing entanglement. Promptly cut-off flush,file smooth,and treat to prevent corrosion. Note:Peen Tee-Nuts and Pletwashers to match radius of pipe affer assembly is complete. Note:Loctite(supplied by others)should be used on any non-patch hardware. INSTALLATION INSTRUCTIONS: 1.Refer to your overhead drawing to locate the four posts,which will receive the Plastic Square Roof. All 4 posts must be at the same height,with a minimum 72'clearance over any deck below. As the posts are not Included in this package,they must be Installed per separate Instructions prior to Installing this roof. 2.Lower the roof over the posts so that the tops of posts extend Into the Inner holes as shown In the assembly drawing and level. Lower Arch of roof should be at least 72"above the deck surface. Raise roof accordingly to ensure this minimum for adequate head clearance. 3.Using the indentations as templates,field drill 3/16'diameter hole to receive self-drilling screw. 4.Use 5/16"magnetic socket driver on the end of a variable speed drill or hand-ratchet to drive a Self-Drilling Screw through the plastic of the roof and the wall of the upright post for each comer at the location shown In the posts fastening detail until all four comers are secured.Detail 135. 5.Eliminate sharp points and sharp edges(burring)on installed hardware like bolts,nuts,etc. 6.Install resilient surfacing material within the use zone of play structure,In accordance with ASTM specifications F1292 appropriate for the fall height of each structure. Refer to the Safety Guidelines. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and tighten as necessary.Check all plastic parts for breakage or wear,and immediately put equipment out of service until any faulty parts found are repaired or replaced. Check for cracks or breakage on plastic,check for openings on plastic junctions.Check periodically resilient surfacing for appropriate depth and remove extraneous materials that could cause injury,infection,or disease.Maintain detailed installation,Inspection,maintenance,and repalr records for each public-use playground equipment. Issued/Revised: 03/10/11 SHEET 1 OF 4 buramax 63995 CURVY CANOPY CURVY CANOPY (306926) II It tl tt 123 ii � i it UNDERNEATH � 1 tl ii it It t 1 :- II -1 11 II II 11 ii ii 11 II tl 11 II tl 11 1 1 I t 1 1 -- t t t t t DECK AND POSTS II tl II tt It It SOLD SEPARATELY LJ LJ 11 II U FINISHED ASSEMBLY a =INSTALLATION DETAIL IssuedlRevised: 03/10/11 SHEET 2 OF 4 buramax 63995 CURVY CANOPY ---- 65 5116'[1659mm] 65 5116"[1659mm] t TOP VIEW MIN.72" [1829mm] L...1 O£CK HEIGHT t 10"[254mm] 30"[762mm) T �.: L.' •� ELEVATION VIEW IssuedlRevised: 03/10/11 SHEET 3 of 4 IOINCH 1 2 3 II 4 ! II 5 6 Lt�l�l�Ilt�l�,l�i Il�I�tIFI1�k�E�lll�ll��I�tllll�l�l'I�I�III�IIIflltll�1�111'IIE�1,�(�1�(,EIl�I�i�i� OCM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 63995 CURVY CANOPY CURVY CANOPY #14 x 3"SELF DRILLING SCREW (ea9sse� 1f4"FLATVVASHER (817408) FIELD DRILL 3/16"DIA.HOLE 3 1/2"O.D. SELF-TAPPING POST SCREW 135 IsswcIRevW. 03/10/11 SHEET 4 OF 4 Quramax 69046 (Z-0r), 69047 (Z-8113'-4t), 69048 (4'-0'), 69049 (4'-81; 5=4"), 69050 (6'-O') Vertical Access Ladder Parts List DESCRIPTION 69048 69047 69048 69049 69050 PART NUMBER 3 1/2"O.O. DECK CLAMP 2 2 2 2 2 301731 VERTICAL ACCESS LADDER,2' 1 0 0 0 0 309816 VERTICAL ACCESS LADDER,2'-8" 0 1 0 0 0 309820 VERTICAL ACCESS LADDER,4' 0 0 1 0 0 309823 VERTICAL ACCESS LADDER,4'-8" 0 0 0 1 0 309825 VERTICAL ACCESS LADDER,6' 0 0 0 0 1 309829 SPLIT ENTRANCE 2 2 2 2 2 313623 HARDWARE COMPLETE 1 0 1 0 1 309849 HARDWARE COMPLETE 0 1 0 1 0 309850 8'EXTENSION 0 2 0 2 0 307623- 114"x 3/4'DRIVE RIVET 2 2 2 2 2 168449' 3/8'x 1 1/4"P.B.H.C.S.w/PATCH 2 2 2 2 2 812051 3/8'x 1 i/2"P.B.H.C.S.w/PATCH 4 4 4 4 4 812053' 3/8"x 2"HEX HEAD BOLT 0 2 0 2 0 801007' 3/8"LOCK WASHER 0 2 0 2 0 817334' 3/8'FLAT WASHER 4 4 4 4 4 817410' 3/8'FLAT WASHER(1 114"O.D_) 2 2 2 2 2 817424' 3/8"HEX NUT 0 2 0 2 0 804053` 3/8"HEAVY HEX NUT 2 2 2 1 2 2 804200` 3/8'LOCK NUT 2 2 2 2 1 2 804353' 3/8"BARREL NUT 2 2 2 1 2 1 2 804804' Unless Otherwise Speed,All Units of Measure are Each 'Items fisted below Hardware Complete line are included With Hardware Complete Number Warning:During Installation,Hardware And Small Parts Are Choking Hazards For Young Children.Store Unused Parts Appropriately Until Assembly Is Completed.Once Assembly Is Completed,Remove Any Unused Parts From The Play EnvironmentAnd Disposa/Save Them in A Secure Location.Any bolt and protruding more than two full threads beyond the face of the nut causes risk of clothing entanglement. Promptly cut-off flush,fl/e smooth,and treat to prevent corrosion. Note:Peen Tee-Nuts and Flatwashens to match radius of pipe after assembly is complete. Note:Loctfte(supplied by others)should be used on any non-patch hardware. INSTALLATION INSTRUCTIONS: 1.Select the appropriate deck to receive the Vertical Access Ladder.Dig footing holes at appropriate locations and position the lower ends of the Ladder into footing holes. 2.Attach 3 1/2'O.D.Deck Clamp to upright using 3/8"x 1 1/2"P.B.H.C.S.w/Patch,and 3/8"Heavy Hex Nut.Refer to Elevation View for Clamp height and location. See Detail 001. 3.Attach Split Entrance to 3 1/2"O.D.Deck Clamp using 3/8"x 1 1/2'P.B.H.C.S_w/Patch,3/8'Flat Washer,and 3/8"Barrel Nut See Detail 797. 4.Insert smashed end of Split Entrance through the slot on top of the Deck.Attach Vertical Ladder to Deck flange and Split Entrance smashed end using 3/8"x 1 1/4"P.B.H.C.S.w/Patch,3/8"Flat Washer,3/8"Flat Washer(1-1/4"O.D.),and 3/8'Locknut as shown in Detail 439. Issued(Revised: 11/19/2015 SHEET 1 OF 4 Duram,ax 69046 (2'--0`g, 69047 (Z-81F X-4'), 69048 (4'-0'), 69049 (4'-8'; 5'-44'), 69050 (6'-0'} Vertical Access Ladder IMPORTANTI Avoid creating any gaps between the components which fall between 3-112"and 9". It has been shown that such gaps create entrapment points which can trap a child and cause Injury. 5,Vertical Access Ladders at 3'-4"and 6-4'deck heights require an extension.Attach extension to legs of ladder using 3B'z 2"Hex Head Boit,3/8`Lockwasher,and 3/8'Hex Nut.See Detail 095. 6.Plumb and level the entire Vertical Ladder Assembly and tighten all fasteners_Pour concrete footing to within 4"to the top and taper away from posts to allow water drainage.Allow to cure at least 48 hours before use. 7_When the structure is finished and satisfactory,install Drive Rivets in all clamps to ensure clamps cannot slidp,down posts. See Ring Clamp subassembly sheets.!f Is very lm1sortaCtt that all Drive Rivets be installed prior to allowing use o;the egu4pment,as clamps ane not deslttned to support substantial welaht without them.Install resilient surfacing material within the use zone of play structure in accordance with ASTM specifications F1292 appropriate for the fall height of each structure. Refer to the Safety Guidelines. Eliminate sharp points and sharp edges(burring)on installed hardware like bolts,nuts,etc. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and tighten as necessary.Always check all parts for breakage or wear,and immediately put equipment out of service until any faulty parts found are repaired or replaced. Also Check all metal parts for rust,paint loss and touch-up if necessary with paint.Check for welded areas and verify integrity_Check periodically resilient surfacing for appropriate depth and remove extraneous materials that could cause injury,infection,or disease. Maintain detailed installation,inspection, maintenance,and repair records for each public-use playground equipment. 797. C SPLIT ENTRANCE (313623) I � I ( I 31 "O.O. DECK I I ( I CLAMP(301731) Ir I x,'439: I 1►J`. I I VERTICAL ACCESS LADDER (309829) I II L ( I II ONLY ON 3'-4'AND l J 5'-4"HEIGHTS O =INSTALLATION DETAIL FINISHED ASSEMBLY COMPONENTS SHOWN IN 8'VERISON SHOWN HIDDEN LINES ARE SOLD SEPARATELY IssuedlRevised. 11/19/2015 SHEET 2 OF 4 Duramax 69046 (Z-0'), 69047 (2'-8';3'-4'), 69048 (4'-0'9, 69049 (4'-8'; 5'4'9, 69050 (6'-0') Vertical access Ladder 36 in [91.44 cm] Sin � \ (12.78 cm] � 1 018 in 014in � � / [45.72 cm] [35.56 cmJ REF TYP. 18 7/8 in 8 1/16 in 150.46 cm) 120.48 cm) PLAN VIEW 14 11/16 in [37.30 cm] 44 �a I I I ( 2 15/16 in CONCRETE REQUIRED: 39 9/16 in ( [7•5cm] 0.14 CUBIC YARDS [100.50 cm] ( I I I [0.10 CUBIC METERS] I I I f DECK HEIGHT I I ( I II II 10 in [25.40 cm) I ( RESILIENT I I SURFACE 30 in [76.20 cm) 20 in } �:• [50.80 cm] ELEVATION VIEW BRICK OR EQUIVALENT Issued/Revised: 11/19/2015 SHEET 3 OF 4 1INCH I I I I,�,I, ,I���I� �I,�,I, , ,�,i, 1 11 OCM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 69046 (2'-0'), 69047' (2'-8',3 '-4'), 69048 (4'-0'), 69049 (4'-8';5'-4'), 69050 (W-0') Vertical Access Ladder LEG(PIPE DIA.) BOLT REQUIRED 1 5116'[3.3 cm) 3/8"x 2"HEX HEAD (801007) UPRIGHT 1 518"14.1 cm] 318"x 2 112"HEX 318"HEAVY HEX NUT POST HEAD(801009) (804200) 1 7/8'[4.7 cm] 3/8"x 3"HEX HEAD LEG,SEE CHART (801011) DKK FOR SIZE 23!8"[8 0 cm) 318"x 3 1/2"HEX CLAMP HEAD(801013) 2 7/8"[7.3 cm) 3/8"x 4"HEX HEAD (801015) DRILL USING 318" EX NUT 1/4"DRILL BTT (804Q53) TO RECEIVE DRIVE RIVET SEE CHART 3/8"LOC ASHER FOR SIZE (817334) 1/4"x 314"D IVE 3/8"x 1 1/2" RIVET(168449) P.B.H.C_S.w/PATCH EXTENSION (812053) /\001,# 3/8'x 1 1/2' P.B.H.C.S_w/PATCH (812053 318" FLAT WASHER ENTRY 817410) ARCHWAY ENCLOSURE 318'FLAT WASHER (817410) CLAMP ;ASHER 318'LOCK N(804353) 3/8"FLADDER (1 114"O.D.)(817424) 3/8"BARREL N T (804804) (43911 /797 Issued/Revised 11/1912015 SHEET 4 OF 4 buramax 69302 SQUARE DECK 69303 TRIANGLE DECK Parts List DESCRIPTION 69302 69303 PART NUMBER SQUARE DECK 1 0 312807 TRIANGLE DECK 0 1 312811 HARDWARE COMPLETE 1 0 312641 HARDWARE COMPLETE 0 1 312864 3/8"x 3/4"P.B.H.C.S.w/PATCH 2 2 812052' 3/8"x 1 114"P.B.H.C.S.w/PATCH 4 3 812D51' 3/8"LOCK WASHER 2 2 817334` 3/8"FLAT WASHER(1 1/4"O.D.) 6 5 817424' 318"T-NUT 2 1 2 804556• Unless Otherwise Specified,AN Units of Measure are Each 'Hems listed below Hardware Complete line are included with Hardware Complete Number Warning:During Installation,Hardware And Small Parts Are Choking Hazards For Young Children.Store Unused Parts Appropriately Until Assembly Is Completed.Once Assembly is Completed,Remove Any Unused Parts From The Play Environment And Dispose/Save Them In A Secure Location.Any bolt end protruding more than two full threads beyond the face of tate nut causes risk of clothing entanglement. Promptly cut-of/flush,i91e smooth,and treat to prevent corrosion. Note:Peon Tee-Nuts and Flatwashers to match radius of pipe after assembly/s complete. Note:Loctite(supplied by others)should be used on any non-patch hardware. INSTALLATION INSTRUCTIONS: 1.Place Uprights in dug holes at appropriate height per Upright instructions.Get the height required for the deck from the Plan View Diagram. 2.Using a 7/16"drill bit, ream out any excess'Plastisol"coating from all holes used on the Deck Be careful not to expost the steel. 3.Attach Deck to Uprights using 318"x 1 114"P.B.H.C.S.w/Patch and 318"Flat Washer(1 1/4"O.D.), See Detail 717. 4.Attach side-by-side Decks to one another using 3/8"x 3/4"P.B.H.C.S.w/Patch,3/8"Lock Washer.3/8"Flat Washer(1 1/4"O.D.),and 3/8"T-Nut,See Detail 061. 5.When all decks are completed and correct,pour concrete footings within 4'to the top and taper away from support posts to allow water drainage.Allow curing at least 48 hours before use. 6.When structure is finished and satisfactory,eliminate sharp points and sharp edges(burring)on installed hardware like bolts,nuts,etc. Install resilient surfacing material within the use zone of play structure in accordance with ASTM specifications F1292 appropriate for the fall height of each structure.Refer to the Safety Guidelines. Note:To cushion accidental fads by children,Paris Structures strongly recommends that the area under and around the play structure must be covered with a resilient material,such as sand,mulch,etc.to a minimum depth of 10"for sand.Approved rubber safety matting can also be used.For details, please refer to your Safety Guidelines,provided within the assembly instructions packet. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and tighten as necessary.Always check all parts for breakage or wear,and immediately put equipment out of service until any faulty parts found are repaired or replaced.Also Check all metal parts for rust,paint loss and touch-up if necessary with paint Check for welded areas and verify integrity.Check periodically resilient surfacing for appropriate depth and remove extraneous materials that could cause injury,infection,or disease.Maintain detailed installation,inspection, maintenance,and repair records for each public-use playground equipment, lmed/Reviwd: 5/27/2014 SHEET 1 OF 4 i Duramax 69302 SQUARE DECK 69303 TRIANGLE DECK �a SQU II II II II II jj I I ( �DECK j it it II II II it II II i I I j I I I I I ( I I TRIANGLE DECK I I i (312811) I ( I I i f 7,7:; I I 1I I I I I I UNDERNEATH I I I II II II � I II ! I II II II I ! <'71r� l I i I I I I UNDERNEATH I I I I I I I I lJ I I lJ lJ II SQUARE DECK II LJ TRIANGLE DECK 0 =INSTALLATION DETAIL COMPONENTS SHOWN IN FINISHED ASSEMBLY HIDDEN LINES ARE SOLD SEPARATELY Issued/Revised. 5/27/2014 SHEET 2 OF 4 Duramax 69302 SQUARE DECK 69303 TRIANGLE DECK 36 in [91.47 cm] 36 in (91.47 cm] f � 50 15118 in 9518 in [129.32 cm] [45.72 cm] REF. PLAN VIEW ri ri 11 II II II II II II it II II it II Il II 48.n 1121.92 cm] I I I 10 in I ( I I [25.40 cm] RESILIENT SURFACE 30 in ,� [7&20 cm] F., C.�.I I I 20 in (50.80 cm) BRICK OR EQUIVALENT—✓ ELEVATION VIEW 69302 SHOWN (swed/Revised: 5/27/2014 SHEET 3 OF 4 q INCH I#I11(t(t,t�rlttltfftlr 1r�t�tlId.�tt(rlr!rlr tlrItlt I tlrlrI'll[]I.I I I rlrIr 111.1rltlt I.IJ.III 111111 111111111 MI 1I oil I kill I Iloilo 11111 oil 1111111111 1111 1911TH 111111111141 it still 11111111 11 111ti I III 111111111111111 1 If 111111 111 OCM 1 2 3 4 6 6 7 8 8 10 11 12 i3 14 16 69342 SQUARE DECK 69303 TRIANGLE DECK DECK—\ DEMCKS 318'T-NUT(804556) s ••• UPRIGHT • 3/8'LOCKWASHER (817334 318'x 1 114 P.B.H.C.S.w1PATCH (812051) 3/8"F T WASHER (1 114'O.D.)(817424) 318"x 3/4' ,B.H.C.S. 3/8"FLAT WASHER w1PATCH(812052) (11/4-O.D.)(817424) F 11 Issued/Revised 5/27/2014 SHEET 4 OF 4 I Duramax 69307 (24'); 69308 (32'); 69309 (40'); 69310 (48'); 69311 (56'); 69318 (64'); 69319 72" INCLINED WALL CLIMBER Parts List DESCRIPTION 69307 69308 69309 69310 69311 69318 69319 PART NUMBER 3 1/2"O.D.DECK CLAMP 2 2 2 2 2 2 2 301731 INCLINED WALL FRAME 24" 1 0 0 0 0 0 0 312867 INCLINED WALL FRAME 32" 0 1 0 0 0 0 0 312869 INCLINED WALL FRAME 40" 0 0 1 0 0 0 0 312871 INCLINED WALL FRAME 48" 0 0 0 1 0 0 0 312873 INCLINED WALL FRAME 56" 0 0 0 0 1 0 0 312875 INCLINED WALL FRAME 64" 0 0 0 0 0 1 0 312877 INCLINED WALL FRAME 72" 0 0 0 0 0 0 1 312879 INCLINED WALL 24" 1 0 0 0 0 0 0 312882 INCLINED WALL 32" 0 1 0 0 0 0 0 312883 INCLINED WALL 40" 0 0 1 0 0 0 0 312884 INCLINED WALL 48' 0 0 0 1 0 0 0 312885 INCLINED WALL 56" 0 0 0 0 1 0 0 312886 INCLINED WALL 64" 0 0 0 0 0 1 0 312887 INCLINED WALL 72' 0 0 0 0 0 0 1 312888 SPLIT ENTRANCE 2 2 2 2 2 2 2 313623 HARDWARE COMPLETE 1 0 0 0 0 0 0 312921 HARDWARE COMPLETE 0 1 0 0 0 0 0 312922 HARDWARE COMPLETE 0 0 1 0 0 0 0 312923 HARDWARE COMPLETE 0 0 0 1 0 0 0 312924 HARDWARE COMPLETE 0 0 0 0 1 0 0 312925 HARDWARE COMPLETE 0 0 0 0 0 1 0 312926 HARDWARE COMPLETE 0 0 0 0 0 0 1 312927 1/4'x 3/4"DRIVE RIVET 2 2 2 2 2 2 2 168449' 3/8"x 1 1/2"P.B,H.C.S.wIPATCH 10 12 12 14 16 18 20 812053` 318'x 1 3/4"P,B.KC.S.w/PATCH 2 2 2 2 2 2 2 812054' 318"LOCKWASHER 8 10 10 12 14 16 18 817334' 3t8"FLAT WASHER 2 2 2 2 2 2 2 817410' 3/8"HEAVY HEX NUT 2 2 2 2 2 2 2 804200` 3/8'T-NUT 2 2 2 2 2 2 2 804556• 3/8'BARREL NUT 8 10 10 12 F14 1 16 18 604804' Unless Otherwise Specified,Aft Units of Measure are Each 'Items listed below Hardware Complete line are included with Hardware Complete Number Warning:During installation,Hardware And Small Parts Are Choking Hazards For Young Children.Store Unused Parts Appropriately Unto Assembly is Completed.Once Assembly is Completed,Renmve Any Unused Parts From The Play Environment And DlsposeelSave Them In A Secure Location.Any bolt end protruding more than two full threads beyond the face or the nut causes risk of clothing entanglement Pmmpt/y cut-off flush,Me smooth,and treat to prevent corrosion. Note:Peen Tee-Nuts and Fletwashers to match radius of pipe after assembly is complete. Note:Loctite(supplied by others)should be used on any non-patch hardware. IssuedlRevW. 11/23/2015 SHEET 1 OF 5 Duramax 69307 (24'); 69308 (32'); 69309 (40'); 69310 (48"); 69311 (56'); 69318 (64'); 69319 2' INCLINE© WALL LIMBER 1NSTAU AT70N INSTRUCTIONS: 1. Determine which deck to receive the Inclined Wall Climber. Refer to Plan View drawing for location. 2_Dig footing holes at locations shown in Plan View. 3.Using a 7/16'-drill bit,ream out any excess"Plastisol"coating from all holes used on the Deck. Be careful not to expose the steel. 4.Using Detail-001 and Elevation View,locate and fasten two Deck Clamps to Upright Posts using 318"x 1-112"P.B.H.C.S.w/Patch,and 3/8"Heavy Hex Nut. 5.Using Detail-797,attach Split Entrance m Upright Posts using Deck Clamps and fasten with 318"x 1-112"P.B.H.C.S.w/Patch,3/8"Flat Washer,and 3/8"Barrel Nut 6. Using Detail-725,attach Frame and Split Entrance smashed ends to Deck with 3B"T-Nut,3/8"Lock Washer, and 318"x 1-314"P.B_H.C.S.w/Patch. IMPORTANTI Avoid creating any gaps between the components which fall between 3.112"and 9".It has been shown that such gaps create entrapment points which can trap a child and cause injury. 7.Attach HDPE climbing wall to frame using 318"x 1-112"P B H.C.S.w/Patch.318"Lockwasher,and 3/8"Barrel Nut as shown in Detail-276. 8. Plumb and level the entire assembly and tighten all fasteners. 9. Pour concrete footings within 4"to the top and taper away from posts for water drainage.Allow to cure at Feast 48-,hours before use 10.When the structure is finished and satisfactory,install 1/4"x 3/4"Drive Rivets in all Clamps to ensure Clamps cannot slide down posts, referring to Typ.Clamp Detail.Eliminate sharp points and sharp edges(burring)on installed hardware like bolts,nuts,etc.if/s very important that all Drive Rivets be installed prior to allowing use of equipment as clamps are not designed to support substantial weight without them. Install resilient surfacing material within the use zone of play structure in accordance with ASTM specifications F1292 appropriate for the fall height of each structure.Refer to the Safety Guidelines. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and tighten as necessary.Always check all parts for breakage or wear,and immediately put equipment out of service until any faulty parts found are repaired or replaced.Also Check all metal parts for rust,paint toss and touch-up if necessary with paint.Check for welded areas and verify integrity.Check periodically resilient surfacing for appropriate depth and remove extraneous materials that could cause injury,infection,or disease. Maintain detailed installation, inspection, maintenance,and repair records for each public-use playground equipment. Issued/Revised: 11/23/2015 SHEET 2 OF 5 buramax 69307 (24'); 69308 (32'); 69309 (40'); 69310 (48" ; 69311 (56'); 69318 64' 69319 72 INCLINED WALL CLIMBER 7s7 . l I SPLTf ENTRANCE (313623) / ( I ( I 3 1/2'O.D,DECK I CLAMP(301731) I I I 01 I I I -j I . INCLINED WALL 32 • ( 312883) 00 0 I I I ( I 0 (30 I I I II INCLINED WALL FRAME I I (312883) l�J 0=INSTALLATION DETAIL FINISHED ASSEMBLY COMPONENTS SHOWN IN 69308 SHOWN HIDDEN LINES ARE SOLD SEPARATELY IssuedMevised: 11/23/2015 SHEET 3 OF 5 Duramax 69307 (2417; 69368 {32 ); 69349 (4(� ), 69310' (48'); 69311 (56'); 69318 64' 69319 721 �' INCLINED WALL LIMBER 36 in [91=44 cm] 018 in 419 [45.72 cm] REF. CONCRETE REQUIRED `0.14 CUBIC YARDSDEM."A"0.10[CUBIC METERS] 014 in 8 9116 in in [35.56 cm] [21.70 cm] [48.26 cm] T'P, PLAN VIEW DIMENSION"A" 14 11116 in MODEL DECK HEIGHT DIM."A" [37.30 cm] 69307 24" 9"[229 mm 69308 32" 1 0 mm 69309 40" 15"[377 mm] I ( I J 69310 48" 18 451 mm 693111 56" 201/2` 525 mm 69318 64" 23 1/2` 599 mm I I I I ( 69319 [1100 72" 26 1/2"[673 mm] 9116 in I I I 0.50 cm] II it 215,16 in I [7.54 cm] I I I I 1I ( DECK 10 in I I v I ' HEIGHT I 1 I 125.40 cm] RESILIENT SURFACE I I I I 30 in t + [76.20 cm] 20 in (50.80 cm] ELEVATION VIEYS/ MICK OR EQUIVALENT 69307 SHOWN Issued/Revised: 11/23/20315 SHEET 4 OF 5 �INCH11111 111 OCM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 69307 (2469308 (32 )," - 69309 40'); 69310 (48'); 69311 8 56" "6931 64" 69319 72" INCLINED WALL CLIMBER UPRIGHT 318"HEAVY HEX NUT POST (804200) DECK FRAME 3/8"BARREL NUT CLAMP (804804) DRILL USING 1/4"DRILL BIT 318"x 1 /2" TO RECEIVE P.B.H.C.S. w/PATCH DRIVE RIVET (812053) 1/4"x 3/4" I VE 3/8"x 1 1/2* RIVET(168449) P.B.H.C.S.w/PATCM 2�f HDPE x`0011 (812053) 3/8"LOC ASHER-.1 PANEL (817334) SPLIT ENTRANCE 3/8"x 1 1/2" P.B.H.C.S.w1PATCH (812053 3/8"FLAT WASHER 817410) IMPORTANT: INSTALL SPLIT 3/8"T-NUT(804558) ENTRANCE TO INSIDE EDGE OF DECK SLOT ENCLOSURE 318"LOCKWASHER CLAMP (817334) I FSE 3/8"x 1 3/4" 3/8"BARREL N P.B.H.C.S.w/PATCH (804804) (812054) <'725) (797",> IssuedlRevised: 11/23/2015 SHEET 5 OF 5 ,:. . �, s.. ,� ,` .. �� r Y t t � i 1 fa � x _. -, Duramax 69331 4' Single Velocity Slide69332 5'-4" Single Velocity Slide69333 8 Single Velocity Slide69333 8 Single Velocity Slide 69333 8 Single Velocity Slide Parts List DESCRIPTION 69331 69332 169333 PART NUMBER 4'SINGLE VELOCITY SLIDE 1 0 1 0 176186 5'-4"SINGLE VELOCITY SLIDE 0 1 0 176187 8'SINGLE VELOCITY SLIDE 0 0 1 176689 FOOTBUCK 1 0 0 176385 FOOTBUCK 0 1 1 168608 SUPPORT PIPE ASSY 0 0 1 177159 3 112"O.D. PIPE CLAMP 2 2 2 301727 HOOD PIPE ASSY 2 2 2 304278 SINGLE SLIDEHOOD 1 1 1 312932 HARDWARE COMPLETE 1 1 0 301587 HARDWARE COMPLETE 0 0 1 312242 6'EXTENSION 0 0 1 151080" 1/4"x 3/4"DRIVE RIVET 2 2 2 168449' 318"x 318"SET SCREW 2 2 2 811549' 3/8"x 3/4"P.B.H.C.S, w/PATCH 2 2 2 812052" 3/8'x 1"P.B.H_C.S,w/PATCH 0 0 2 812050* 3/8'x 1 1/4*P.B.H,C.S.w/PATCH 2 2 2 812051` 318"x 1 1/2"P.B.H.C.S,w/PATCH 2 2 2 812053' 3/8'x 2"THREADED ROD 2 2 2 803560' 318"x 2 1/2'P.B.H.C.S.w/PATCH 2 2 2 812057" 3/8"x 3 1/2"HEX HEAD BOLT 0 0 1 801013* 318"LOCKWASHER 2 2 5 817334" 3/8"FLAT WASHER(1"O.D.) 2 2 2 817401' 3/8*FLAT WASHER 2 2 4 817410' 3/8'FLAT WASHER(1 1/4"O.D.) 2 2 2 817424' 3/8"HEX NUT 0 01 804053* 318'HEAVY HEX NUT 2 2 2 804200* Unless Otherwise Speed,All Units of Measure are Each *Items fisted below Hardware Complete line ere included with Hardware Complete Number Warning.During lnstallatfon,Hardware And Small Parts Are Choking Hazards For Young Children.Stone Unused Parts Appropriately Until Assembly Is Completed.Once Assembly is Completed,Remove Any Unused Parts From The Play Environment And Dispose/Save Them In A Secure Location.Any bolt end protruding more than two full threads beyond the face of the nut causes risk of clothing entanglement. Promptly cut-off ffush,We smooth,and treat to prevent corrosion. Note:Peen Tea-Nuts and Ftatwashers to match radius of pipe after assembly is complete. Note:Loctite(supplied by others)should be used on any non-patch hardware. Issued/Revised: 1/20/2016 SHEET 1 OF 10 D u ramax 69331 4' Single Velocity Slide69332 5`-4" Single Velocity . Slide69333 8' Singrle Velocity Slide69333 8' Single Velocity Slide 69333 8 Single Velocity Slide INSTALLATION INSTRUCTIONS: 1.Determine which deck is to receive the slide and dig footing at location shown in Top View.Refer to the Elevation View for footing depth. 2.Attach Pipe Clamps to uprights using 3/8"x 1 1/2"P.B.H.C.S.w/Patch and 318"Heavy Hex Nut as shown in Detail 041.Refer to Elevation View for clamp height and orientation. 3.Attach the Hood Pipe Ass y to Single Slide Hood using 3/8'Threaded Rod See Detail 705. 4.Place Slide Hood Pipes from Single Slide Flood into Pipe Clamps and set in place with 3/8"x 3/4"Set Screw_See Detail 041. 5.Attach Foot Buck to Single Velocity Slide with 3/8"x 314"P,B.H.C.S,w/Patch,3/8"Lock Washer,and 318'Flatwasher.See Detail 024. 6.If installing 69333,attach 6"Extension to Support Post Ass'y using 3/8"x 31/2"Hex Head,3/8"Lock Washer,and 3/8"Hex Nut.See Detail 171. 7.When installing 69333,attach Support PostAssy with 6"Extension to Slide using 3/8"x 1"P.B.H.C.S.w/PATCH, 3/8"Lock Washer, and 3/8'Flat Washer.See Detail 172. 8.Place Foot Buck into tooting holes and attach Single Velocity Slide to Single Slide Hood to using 3/8"x 2 112'P.B.H.C.S.w/Patch and 3/8"Flat Washer(1'O.D.).See Detail 708. 9,Attach Single Velocity Slide to deck using 3/8"x 1 1/4"P.B.H.C.S.w/Patch and 3/8"Flat Washer.See Detail 136. 10.When the Slide is plumb and level,tighten all fasteners and pour concrete footings within 4"to the top and taper away from supports to allow drainage.Allow to cure at least 48 hours before use. IMPORTANTI Avoid creatine{any gaps between the components which fall between 3-112"and 9".It has been shown that such gaps creatia entrapment points which can trap a child and cause Injury. 11.When structure is finished and satisfactory,tighten all fasteners and install Drive Rivets in all clamps to ensure clamps cannot slide down posts.See Pipe Clamp sub-assembly sheet.It is yefy important that aft Drive Rivets be installed prior to&►lowing use of ee ufpment,as clamps are not designed to support subsianda/weight without them.Also Eliminate sharp points and sharp edges(burring)on installed hardware like bolts.nuts,etc.install resilient surfacing material within the use zone of play structure in accordance with ASTM specifications F1292 appropriate for the fall height of each structure_Refer to the Safety Guidelines. MAINTENANCE PROCEDURE: Periodically check hardware for tightness,and tighten as necessary.Always check all parts for breakage or wear,and immediately put equipment out of service until any faulty parts found are repaired of rgptaced.Also Check all metal parts for rust,paint loss and touch-up if necessary with paint.Check for welded areas and verify integrity.Check periodically resilient surfacing for appropriate depth and remove extraneous materials that could cause injury,infection,or disease.Maintain detailed installation,inspection, maintenance,and repair records for each public-use playground equipment. Issue&Revised: 1/20/2016 SHEET 2 01710 D u ramax 69331 4' Single Velocity Slide69332 5'-4" Single Velocity Slide69333 8' Single Velocity S/ide69333 8' Single Velocity Slide 69333 8 Single Velocity Slide HOOD PIPE ASSY (3Q4278) 1+705; t UNDERNEATH NGLE SLIDEHOOD (312932) CLAMP(30 727) I � I F I X708, f BEHIND II I 4'SINGLE VELOCITY SLIDE (176186) it I UNDERNEATH I I I I I ll LJ FCXMWCK (176385)-/ UNDERNEATH UNDERNEATH 0 =INSTALLATION DETAIL FINISHED ASSEMBLY COMPONENTS SHOWN IN 69331 SHOWN HIDDEN LINES ARE SOLD SEPARATELY Issued/Revised 1/20/2016 SHEET 3 OF 10 i i i b u ramax 69331 4' Single Velocity Slide69332 5'-4" Single Velocity S/ide69333 8 Sin le Velocity S/ide69333 8 Single Velocity Slide 69333 8' Single lVelocitySlide UNDERNEATH f HOOD PIPE ASSY (304278) { I . SIN LE SLIDEHOOD 3 112"O.D.PIPE ( (312932) CLAMP(301727) I I I BEHIND o I � r I I 5'4"SINGLE VELOCITY SLIDE (176187) UNDERNEATH II ll ` ff LJ FOOTBUCK (0�2;� (168608) UNDERNEATH FINISHED ASSEMBLY COMPONENTS SHOWN IN O=INSTALLATION DETAIL 69332 SHOWN HIDDEN LINES ARE SOLD SEPARATELY Issued/Revised 1/20/2016 SHEET4 OF 10 Duramax 69331 4' Single Velocity Slide69332 5`-4" Single Velocity Slide69333 8 Sin le Velocity Slide69333 8 Single Velocity Slide 69333 8' Single Velocity Slide (041HOOD PIPE ASSY (304278) UNDERNEATH a INGLE SLIDEHOOD (312932) 3 1/2"D.D.PIPE I CLAMP(301727) I I g BEHIND I I B'SINGLE VELOCITY SLIDE 1xf i (176689) UNDERNEATH I ( I 11 II I ) II II II I I LJ II II LJ 172 SUPPORT PIPE ASSY -—'� (177159) UNDERNEATH 6"EXIHVSION (151080) 171 UNDERNEATH UNDERNEATH 024,E FOOTBUO( UNDERNEATH (168608) INSTALLATION DETAIL FINISHED ASSEMBLY COMPONENTS SHOWN IN 69333 SHOWN HIDDEN LINES ARE SOLD SEPARATELY lssued/Revised- 1/20/2016 SHEETS 0F10 buramax 69331 4' Single Velocity Slide69332 5'4" Single Velocity Slide69333 8' Single Velocity Slide69333 8' Single Velocity Slide 69333 8 Single Velocity Slide I \ 1 17 314 in [45.09 cm] 36 in [91.44 cm] / t 014 in t [35.56 cm) t fl 016 in (45.72 cm] 64 71 in REF. [164.71 cm) PLAN VIEW CONCRETE REQUIRED 0.086 CUBIC YARDS F 0.050[CUBIC METERS] NOTE: BEDWAY MUST NOT EXCEED 50"DOWNWARD ANGLE PER ASTM 38 112 in I AND GSA STANDARD. [97.79 cm] EXIT HEIGHT CHART-for-69331 I STANDARD EXIT HEIGHT from SURFACING ASTM T'TO 15' CSA 175mm TO 380mm I EN 350mm OR LESS 48 in I I (121'92 cm] I ( REFER TO EXIT HEIGHT CHART I I 10 in I 125.40 cm) it I I RESIDENT SURFACE 30 in [76.20 cm) I I 19 1/2 in tt I •w (49.56 cm] BRICK OR EQUIVALENT ELEVATION VIEW 69331 SHOWN Issued/Revised 1/2012016 SHEET 6 OF 10 Duramax 69339 4' Single Velocity Slide69332 5'4" Single Velocity Slide69333 8' Single Velocity Slide69333 8' Single Velocity Slide 69333 8' Single Velocity Slide 18 in [45.72 cm] 36 in [91.44 cm] /\ 014 in [35.56 cm] 018 in [45.72 cm] 82 13/18 in REF. [210.42 cm] PLAN VIEW CONCRETE REQUIRED Fj 0.066 CUBIC YARDS 0.050[CUBIC METERS] NOTE: BEDWAY MUST NOT EXCEED 50"DOWNWARD ANGLE PER ASTM 38 1/2 in AND CSA STANDARD. [97.79 cm) EXIT HEIGHT CHART-for-69332 STANDARD EXIT HEIGHT from SURFACING ASTM 7"TO 15" I CSA 175mm TO 380mm Itt EN 350mm OR LESS II 641n 1162.58 cmj ( I REFER TO EXIT HEIGHT CHART 10 in ( ( [25.40 cm] RESILIENT SURFACE 30 in [76.20 cmj } :•j I ti..� t 20 in [50.80 cm] J BRICK OR EQUIVALENT ELEVATION VIEW 69332 SHOWN Issued/Revised: 1/20/2016 SHEET 7 OF 10 Duramax 693314' Single Velocity Slide 69332 5'-4" Single Velocity Slide69333 8' Single Velocity Slide69333 8' Single Velocity Slide 69333 8' Single Velocity Slide 36 in [91.44 cm] 18 in [45.72 cm] 27 1 t8 in Q�18 in 5556 c [45.72 cm] [68.87 cm] [35.56 cm] REF. (2 PLCS) 122 1/2 in [311.15 cm] PLAN VIEW CONCRETE REQUIRED 0.132 CUBIC YARDS 0.100[CUBIC METERS] F NOTE:BEDWAY MUST NOT EXCEED 38112 in 50'DOWNWARD ANGLE PER ASTM AND CSA STANDARD. [97.79 cm] EXIT HEIGHT CHART_for 69333 STANDARD EXIT HEIGHT from SURFACING ASTM 7"TO 15" ( ► CSA 17Smm TO 380mm III EN 350mm OR LESS ( I 96 in t 1243.84 cm] j I I REFER TO EXIT ( I HEIGHT CHART 10 in I [25.40 cm] RESILIENT SURFACE 30 in [76.20 cm] I s ) 20 in ELEVATION VIEW BRICK OR EQUIVALENT [50.80 cm] 69333 SHOWN IssuedlRevised: 1/20/2016 SHEET 8 OF 10 4 qIINCH l,1.1,I��,I,�, ,I,i,�,I,1,I,I, ,I,I,1 1I,i,i,l�1,I,I,I,I im I III I III III 11111111111111111 Iloilo 14 11 11IM11111111111111 III I I 111 1111141111 11111 1111111 1111 loll III I III III pTrrfrT OCM 1 2 3 4 5 6 7 8 8 10 11 12 13 14 15 69331 4' Single Velocity Slide69332 5'-4" Single Velocity Slide69333 8' Single Velocity Slide69333 8' Single Velocity Slide 69333 8' Single Velocity Slide SLIDE 318"x 1 112" 1/4"x 3/4"DRIVE P.B.H.C.S.w/PATCH RIVET(168449) (812053 318"HEAVY HEX NUT 3/8"FLAT WASHER (804200 817410) 3/8"x 3/8"SET SCREW(811549) /8"LOCKWASHER (817334) FOOTBUCK 3/8"x 3 "P.B.H.C.S. COMPONENT w/PATCH(812052) <\041 024) SUPPORT POST 3/8"FLAT WASHER DECK 3/8'LOCKWASHER (1 1/4 O,D.)(817424) 316'HEX (817334) UT (804053) SLIDE 3/8"x 1/4" 3/8"x 3 1 'HEX P.B.H.C.S.w/PATCH HEAD BOLT(80 1013) (812051) EXTENSION </1 36 171/1 Issued/Revised: 1/20/2016 SHEET 9 OF 10 INCH I M I 1111111111 111 IT loll loll loll 1111111 11111111 oil III I M To I III 111 11111111]111111111111141111111111111 if 111 11111 m oil 16 11 111116111111111 loll 111111 11 OCM 1 2 3 4 5 6 7 8 8 10 11 12 13 14 15 69331 4' Single Velocity Slide69332 5'-4" Single Velocity Slide69333 8' Sm Velocity Slide69333 8' Single Velocity Slide 99"333 8' Single Velocity Slide SLIDE HOOD SLIDE 318"FLAT WASHER (817410) SUPPORT POST SLIDE HOOD PIPE 318'LOCKWASHER (817334) 318"x 2' HREADED 3/8"x 1"P.B.H.C.S. ROD(803560) w/PATCH(812050) 172 705;' SLIDE 3/8'FLAT WASHER (1'O.D.)(817401) SLIDE HOOD 318"x 2 112" P.B.H.C.S.w/PATCH (812057) _ t fsswd/Revised: 1/20/2016 SHEET 10 OF 10 fDPW Parks and Cemetary This play egoipien1 is Drawn By r� p�y'y �{ Total Prey Components 12 rocommended for TiHanie Brown !� C' �" Eleveed Prey components 7 user cappcky idge Street children apes: scale: 114"=1'-0" rthhampton MA 01060 5 12 This drawing an be Dale. �l l u u es, Eleveled Play Componenta Accessible by Rsmp 0 Req. 0 15-25 eared only when i1 06/20/17 Elevated Components Accesslble by Transfer 7 Req. 4 CrMW Fall H019M Minimum Area Re an 11'x 1 T formal Quote Number 401 Chestnut et,ate.419 New England Recreaion Group 26'-B"x 25'-1p1"� 642-108618 Chaasnooga,TN 37402 Accessible Ground Levey Components Shown z Req. 2 e' Il00-727-1907 r www.pleyendpuk.com Different Types of Ground Level Components 2 Rep. 2 Q � -YEN. I "c[• Order 7339611 FOOTINGS ORDINATE TABLE HOLEI X Y DIAG 1 —1'-8 1/2" —4'-6" 4'-10" Y 2 —1'-3" —2'-3 1 2" 2'-7 1/2' 7O 12 14 20 23 3 —1'-3" —0'-8 1/2 1'-5" 4 0'-0" —6'-0" 6'-0" X 21 5 0'-0" —3'-0" 3'—O" 3 B 11 17 B O 6 0'-0" 0'-0" 0'-0" 1 -6 19 O 24 7 ' " 1'-7 1/2 2'-2 1/2 " 2B A 10 AQ 16 PEI 18 8 1'-6" —11'-5" 11'-6" 9 3'-0" —6'-0" 6'-8 1/2" 10 22O 10 3'-0" —3'-0" 4'73" 11 3'-0" 0'-0" 3'-0" 4O9 AQ 15 Ao 13 4'-6" —7'0751 2" 388110"2 13O 14 5'-4" 0'-5" 5'-4" 25 K 15 6'-0" —6'-27'-0 16 6'-0" —3'— 17 6'-0" 0'-0 18 7'-0 1/2" —2'-7 8O 26 B 19 7'-0 1/2" —0'-4 20 7'-5" 0'-1 FOOTINGS TABLE 21 8'-3" —1'-3" 8'-4 1/2- TYPE 2"TYPE DIAMETER SIDE DEPTH QTY. 22 8'-7" —4'-6" 9'-8 1/2" A 1'-6" 45.72cm 2'-6" 76.20cm 11 23 9'-8 1/2" 0'-10" 9'-9" B 1'-2" 35.56cm 2'-6" 76.20cm 13 24 10'-1 1/2" —0'-9 1/2" 10'-2" J 1'-0" 30.48cm 2'-0" 60.96cm 1 25 10'-8" —9'-0 1/2- 14'-0" K 3'-0" 91.44cm 2'-6" 76.20cm 1 26 10'-9" —11'-3" 15'-6 1/2" it u g1e manufetturer's opinion that the structuro shown herein complies with current ads standards eonaming accessiblity 9used w"h proper accessible surfacing and together with other necessary ground level play equipmea IMPORTANT:Never Instal play equipment over hard,unreswaftt surfaces such a$asphah,concrete,or compacted earth.It is the owner's responsbhty to ensure the"minimum area required"contains an appropriate amount of resilient maletkal to cushion accidental fsb. r DPW Parks and Cemetery This play*%Apmeht is one—ay Total Play Components 12 recommended for playa pa rk Elevated Play Cor ponents 7 User Capacity Bridge Street children ages: scale: 114"=1'-0" Titfanie Brown .�..}}r } y�� /^\ N"thhairnp MA 01060 07.12 This drawing can be Date: Aruc u C"7* EJeveled Play Components Accessible by Ramp 0 Req. 0 1525 scaled only when in 06120117 .pt.'rcv"r— Elevated Components Accessible by Transfer 7 Req. 1 Crit"FM Height an 11"x 17"format Quote Number: 401 Chestnut St.8%.410 Minimum Area Required: an TN 37401 Accessible Ground Level Componenla Shown 2 Req. 2 84' New England Recreaion Group 26'-8"x 25'-11" 642-108618 e00.727-1ea7I www.gsrsndoart.wm Different Types of Ground Level Components 2 Req, 2 VVaV1��ii I,S'O n•r sn*c�s 0 0 1 Order 7339611 TOTAL SURFACING AREA — 7'-9" REQUIRED 565 SQ FT 90 LINEAR FT LOOP POLE 7'-8" 8" KICKPLATE CLIMBER PIPE 62015 62267 20" g 2 O IKPLATE TRIANGLE VERTICAL ACCESS LADDER TRANSFER POiN 8 KICKPLATE ATE 69047 W�A62348 DH0LD RETUR INCLINE WAL \ STEP CLIMBER I��t 3'4 2'8'r 1'4" 2345 69309 FIREMAN'S 4' 4'8" 5� 25'-11 6204 f f PL62168EL LEG LIFTPIPE WALL 62243 6'41. 62026 BENCH SEAT COIL (BELOW) CLIMBER 63994 63923 STORE PANEL (620032 HURRICANE SPIRAL SLIDE SINGLE B" KICKPLATE 52129 VELOCITY SLIDE 62015 CURVY CANOPY 69331 8" KICKPLATE 63995 62015 R It is the manutecturefs opinion that the structure shown harem cDrrvks with current ads standards concemmg accessibility if used wan proper accessible surfacing and together Mn other necassary ground level play equpmenl IM PORTANTP Never install play equipment over hard,unreskient surfaces such as asphsh,concrete,or compacted earth. It is the ownefs responsibility to ensure the"mintmum area required"contains an appropriate amount of resilient material to cushion accidental fake. 3 L A r ' TMs equipment is ^.a Q Total Play Components 12 rNorthhampton PW Parks and Cemetary mwnrnen for Qf°Wn 9y. ay&p r C Elevated Fl Components 7 user Capacity ridge Street children eyes: Sub: 1/4"=1'-0" Tiffanie Brown /`� ay MA 01060 5 12 This drawing an be Datestructures, ( Elevated Play Components Accessible by Ramp 0 Req. 0 15-25 scaled only when in 06/20/17 •rt�to"�...... \�t�// Elevated Components Accessible by Transfer 7 Req. 4 Critical Fent Hew;"! an 11'x 17"format Quote Number e01 Chestnut SL,Ste.41D New England Recreaion Grose Minnnum Area Required: Accessible Ground Level ComponeMr.Shown 2 Req, 2 6-4 - New P 26'-8"X 25'-11" 642-108618 7-1907naoye.TN snot 5caa27-ta07 r www p4yaneperk.com Different Types of Ground Level Components 2 Req. 2 ISO V Ar Inrt"a a. . 26'-B" Order 7339611 TOTAL SURFACING AREA 7'-9" REQUIRED 565 SQ FT 90 LINEAR FT 7'-8" 15ATT9 15ATT8 15ATTA 1111 �y 4� 2'8� 1'4" 1'1'1 15ATT6 15ATT5 4' 4'a" 5 25'-11" l5ATT4 15ATTD 15ATTC 6'4" 15ATT7 15ATT6 If is the menutach"r's opinion that the swucture shown herein complies with current ads standards conceming accessibility q used with proper accessible surfacing and together with other necessary ground level play equipment. IMPQRTANT',Never install play equipment over hard,unresleent surfaces such as asphalt,concrete,.or compacted earth it m the owner's responsibility to ensure the minimum area required'contains an appropriate amount of resiReM material to c sh1w accidental fab. L J 'i 3 4 4'%� f'i^tom � .. L�'-- fYy�..e >Y �° a o- � ; f T,