18C-045 (13) 72 HATFIELD ST 18C-045 SM-2019-0027 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON SIS# I29 18C �► Block: 045 001 SHEETMETAL PERMIT Permit: SHEETMETAL Category: SHEETMETAL J Permit# SM-2019-0027 PERMISSIONIS HEREBY GRANTED TO: Project# JS 2i71�i�o425s3 Est,Gast: JI3,SO6.0 � Contractor. License: Expires: pee Chatgedt$So 00 ROCK VALLEY HVAC Sheetmetal-2626 04/28/2020 Balance $.00 Owner: Larry Audette I#ofFixtures: Applicant: ROCK VALLEY HVAC I31ge# AT: 72 HATFIELD ST 18C-045 Use Group CoonstClass ISSUED ON. 19-Oct-2018 AMENDED ON.- EXPIRES ON.- TO PERFORM THE FOLLOWING WORK: INSTALL HVAC FOR UNIT B THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2019-001381 18-Oct-18 1158 $50.00 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck. northamptonma.gov GeoTMS®2018 Des Lauriers Municipal Solutions,Inc. File#SM-2019-0027 APPLICANT/CONTACT PERSON ROCK VALLEY HVAC ADDRESS/PHONE 7 APPLEWOOD LN (413)535-7804 PROPERTY LOCATION 72 HATFIELD ST 18C-045 MAP 18C PARCEL 045 001 ZONE 1JRB{100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Tvoeof Construction: INSTALL HVAC FOR UNIT B New Construction Non Structural interior renovations__ Addition to Existing Accessoa Structure BuildingPlans_Included: Owner/Statement or License 2626 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact the Office of Planning&Development for more information. Commonwealth of Massachusetts Sheet Metal Permit /� Date: 10/17/2018 Permit# S�'1 ' P Estimated Job Cost: $13,500.00 R E C E 1 V Ete: $ 5"10Plans Submitted: YES NO Plans I evie ed: YES NO OCT 18 2018 Business License# Applic t L cense# DEPT OF BUILDIN "w r/Job Location Information: BUS1neSS Information: NORTHAMPTO16�Y9a0 Name: Rock Valley HVAC (Jesse Fortier) Name: L.P. Audette Builders Street: PO Box 1162 Street: 72B Hatfield Street City/Town: Easthampton City/Town:Northampton Telephone: (413)535-7804 Telephone: (413) 539-7381 Photo I.D. required/Copy of Photo I.D. attached: YES f NO staff nidal J-1 /M-1-unrestricted license J-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft./2-stories or less Residential: 1-2 family ✓ Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. ✓ over 10,000 sq. ft. Number of Stories:I Sheet metal work to be completed: New Work: ✓ Renovation: HVAC ✓ Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: Provide and install complete HVAC system, fabricate and install custom fabricated sheet metal duct system. All ductwork to be sealed and insulated to energy star standards and installed in conditioned space. All equipment and ductwork sized according to Manual J 8d'edition heat load calculation. Equipment specs-American Standard equipment Furnace model#S9V2B040U3VSA, Cased Coil model #4TXCB003DS3,AC unit model#4A7A4018LL AHRI reference#201812597. INSURANCE COVERAGE: I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch. 112 Yes UNo ❑ If you have checked Yes,indicate the type of coverage by checking the appropriate box below: A liability insurance policy Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER:I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this pennit application waives this requirement. Check One Only Owner Agent ❑ Signature of Owner or Owner's Agent By checking this boxy,I hereby certify that all of the details and information 1 have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES V""NO Progress Inspections Date Comments Final Inspection Date Comments 1isctense: By Maer Title ❑ Master-Restricted City/Town ❑ Joumeyperson Signature of Licensee Permit# ❑ Journeyperson-Restricted License Number: Fee$ ❑ Check at www.mass.gov/dpl Inspector Signature of Permit Approval b. Rock Valley Proect Summa J° J Summary Date: October 1,2018 Entire House By. Rock Valley HVAC Inc. P.O.Box 1162,EaslhamptoR MA 01027 Phors:(413)5357804 Email:Rodwalleytwao@yahoo.eom web:wwwrockvalleytuar-MM Prooect Information For. L.P.Audette Builders 72B Hatfield Street,Northampton,Ma 01060 Phone:(413)539-7381 Notes: Email:audla1950@gmail.com Design Information Weather. Greenfield(Worcester Dd),MA,US Winter Design Conditions Summer Design Conditions Outside db 2 OF Outside db 85 OF Inside db 72 OF Inside db 68 OF Design TD 74 OF Design TD 17 OF Daily range M Relative humidity 50 % Moisture difference 42 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23401 Btuh Structure 9016 Btuh 0 Btuh Ducts 0 Btuh Central vent(0 dm) 0 Btuh Central vent(0 dm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23401 Btuh Use manufacturer's data n Rate/swin multiplier 0.90 Infiltration Equipmengsensble load 8114 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 1 (Tight) Structure 664 Btuh Ducts 0 Btuh g g Central vent(0 dm) 0 Btuh Area 2985 2985 (�) (ftp Equipment latent load 664 Btuh Molume(M 17800 17800 Air changes/hour 0.15 0.08 Equipment Total Load(Sen+Lat) 8779 Btuh Equiv.AVF(dm) 45 24 Req.total capacity at 0.70 SHR 1.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make ModTradel Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating Input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual airflow 636 cfm Actual airflow 636 cfm Airflowfactor 0.027 cfm/Btuh Airflowfactor 0.071 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.93 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. v - ^-wrtl htsoft- 2018-Oct-1708:27:07 r+� s w^�11-- RigWS�Udversal2018 18.0.31 RSU24598 Page 1 roues Loads172B Hatfield Streetnp Calc=MJ8 Frort Door laces:N N Basement Q 72A "' r 72B Job#: Rock Valley HVAC Inc. Scale: 1 : 83 Performed for. Page 3 LP Audette Buiders P.O.Box 1162 taghtSude®U'"asal 2018 72B Hatfield Street Easthampton,MA01027 18.0.31-17 08:598 Northampton,Ma 01060 P 2018-Oct-17 field S50 Phase:(413)5317381 Phone:(413)535-7804 ...at LoadsV2B Hatfield Stieet.rup awe:(413) raican www.rockvalleyhvaccom Rodcvalleyhvac@yahoo.com +r o i N jr`oc>r 4 Zx-V'.-(e-\ First Floor 7a V 1/2 bath Bath Kitchen/Din Kit/Din Q S tains Living Room LR2 u Clos Entryway Foyer wash a n Job M Rock Valley HVAC Inc. Scale: 1 : 83 Performed for. Page 1 LPAudette Builders P.O.Box 1162 t3ghtSuite®Universal 2018 24598 72B Hatfield Street Easthampton,MA01027 18.0.31 RSU8:27: Northampton,Ma01060 p 2018-Oct-17 08:27:49 Phone:(413)539-7381 Phone:(413)535-7804 ...atLoedsv28 Hatfield street.rup Phon1950@g39-73 1 www.rockvalleyhvacoom Rockvalleyhva @yahoo.00m �_,j � � _ ,..F •� fi> N r o� �l�l S c-•`l l�Y Second Floor -7� '✓ C-3 CIO do 2 Bath 3 Bed Bed 2 Bath 2 cs Master We Master We 2 Str 3 FHall Hall 2 str 4 18 Master bed Master bed 2 Master Bath Master Bath 2 C OF Job#: Rock Valley HVAC Inc. Scale: 1 : 83 Performed for. Page 2 L P Audette Buiders P.O.Box 1162 RghtSuie®Universal 2018 728 Hatfield Street Easthampton,MA01027 18.0.31 RSU24598 Northampton,Ma01060 Phone: 413 535-78042018-0ct-170827:50 Phone:(413)539-7381 at Loads\726 Hatfield Street.rup auda1950@gnai.com www.rockvalleyhvacoorrl Rodcvalleyhvac@yahao.00m rr, �r< s A This combination qualifies for a Federal Energy Efficiency tax Credit when placed in service between Feb 17,2009 and Dec 31, 2016. 1 www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number:201812597 Date: 10-17-2018 Model Status:Active AHRI Type: RCU-A-CB Series:SILVER 14 Outdoor Unit Brand Name:AMERICAN STANDARD Outdoor Unit Model Number (Condenser or Single Package):4A7A4018L1 Indoor Unit Model Number(Evaporator and/or Air Handler):4TXCB003DS3 Furnace Model Number:S9V2B040U3VSA Region: All(AK,AL,AR,AZ,CA,CO,CT,DC,DE, FL,GA, HI,ID, IL,IA, IN,KS,KY,LA,MA,MD, ME,MI,MN,MO,MS, MT,NC,ND,NE, NH,NJ,NM,NV, NY,OH,OK,OR,PA, RI,SC,SD,TN,TX, UT,VA,VT,WA,WV,WI,WY, U.S. Territories) Region Note: Central air conditioners manufactured prior to January 1,2015 are eligible to be installed in all regions until June 30,2016.Beginning July 1,2016 central air conditioners can only be installed in region(s)for which they meet the regional efficiency requirement. The manufacturer of this AMERICAN STANDARD product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of ANSI/AHRI 210/240 with Addenda 1 and 2,Performance Rating of Unitary Air-Conditioning&Air-Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored,independent,third party testing: Cooling Capacity(A2)-Single or High Stage(95F),btuh: 18900 SEER: 16.00 EER(A2)-Single or High Stage(95F) : 13.00 t"Active°Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale;OR new models that are being marketed but are not yet being produced."Production Stopped"Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re-rate. The new published rating is shown along with the previous(i.e.WAS)rating. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; .■ `' entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make lite better- and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right ©2018Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 131842530653550463