Loading...
16A-020 704 FAIRWAY VILLAGE BP-2019-0266 GIS#: COMMONWEALTH OF MASSACHUSETTS Man:Block: 16A-020 CITY OF NORTHAMPTON Lot: -000 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Categoor: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2019-0266 Project# JS-2019-000437 Est.Cost: $42960.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: VALLEY SOLAR LLC 077279 Lot Size(sq. ft.): Owner: VIIELE CLAUDIA Zoning:URA(102)/WP(17)//WSP(15)/ Applicant: VALLEY SOLAR LLC AT. 704 FAIRWAY VILLAGE Applicant Address: Phone: Insurance: PO BOX 60627 (413) 584-8844 FLORENCEMA01062 ISSUED ON.91612018 0:00:00 TO PERFORM THE FOLLOWING WORK.-ROOF MOUNTED SOLAR, 34 PANELS 12.775 KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Sienature: FeeType: Date Paid: Amount: Building 9/6/2018 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner Sol� r File#BP-2019-0266 APPLICANT/CONTACT PERSON VALLEY SOLAR LLC ADDRESS/PHONE PO BOX 60627 FLORENCE (413) 584-8844 AU "�eS�7`�G'� � PROPERTY LOCATION 704 FAIRWAY VILLAGE MAP 16A PARCEL 020 000 ZONE URA(102)/WP(17)/WSP(15)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Buildinp,Permit Filled out Fee Paid Typeof Construction: ROOF MOUNTED SOLAR 34 PANELS 12.775 KW New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 077279 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: ��pproved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition Delay G 9SlS Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. ` t ' Department use only ,X,v City of Northampton Status of Permit: Building Department Curb CuUDriveway Permit 212 Main Street Sewer/Septic Availability Room 100 Water/Well Availability Northampton, MA 01060 Two Sets of Structural Plans < phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A(�ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office q04 facu--0-9 V I(ICL v P Map Lot jooA D Unit & ds, OI R 0(0S ) Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: I to P TCA1rU,-)QAU It✓t6 CAQ,� ScIY1a(3' Name(Print) Current Mailing Add r ss: U (TI -- I R- 5)b Telephone Signature i 2.2 Authorized Agent: Valley Solar LLC PO Box 60627, Florence, MA 01062 Name(Print) Current Mailing Address: 5;4z� 413-584-8844 Signature Telephone SECTION 3 -ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only com leted by permit applicant 1. Building (a) Building Permit Fee 2. Electrical (b) Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total = (1 +2+ 3+4+ 5) Check Number This Section For Official Use Only Building Permit Number: Date Issued: Signature: Building Commissioner/Inspector of Buildings Date Ihasbrouck @ northamptonma.gov info(C_vallepolar.solar EMAIL ADDRESS (REQUIRED; 91. CONTRACTOR) Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DONT KNOW O YES Q IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DONT KNOW O YES Q IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO O DONT KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES O NO O IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES, then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors l] Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [Q Siding [O] Other[X Solar Brief Descr tion of Proposed Z �f K UJ Ix 54SMr4l ✓1 W Work: I RI/)I�Q-1Inn q t13�, �Iia nth s6to r pVi1Q Irra- V_I i Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a.If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, 0,I OIL6(3, y Itt as Owner of the subject property hereby authorize Valley Solar LLC to act on my behalf, in all afters rela ive to wqr authorized by this building permit application. Signature of Owner Date Valley Solar LLC as Q u"/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Q Print Name s 3 Signature of Owner/Agent Date r ? SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: ` 1 ' Not Applicable ❑ Name of License Holder: License Number 3-G S Lc-)mel c, \rA caukis CS-0 7T r a-'j G AddressExpiration Date N/� - Signature f VTelephone 612111 g 9. Registered Home Improvement Contractor: Not Applicable ❑ Company Name Registration Number Valley Solar LLC 186338 Address Expiration Date PO Box 60627, Florence, MA 01062 Telephone 413-584-8844 10/27/18 SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L. c. 152,§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes.......V No...... ❑ The Commonwealth of Massachusetts Department of industrial Accidents 1 Congress Street, Suite 100 i 1 Boston, MA 02114-2017 ww11u tnass.gov/dia \Vw-kers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers. TO BE FILED WiTH THE PERMITTiNG AUTHORITY. Applicant Information Please Print Leeibly Name (Business/Organization/Individual):Valley Solar LLC Address:340 Riverside Dr., PO Box 60627 City/State/Zip:Florence, MA 01062 Phone#:413-584-8844 Are you an employer?Check the appropriate box: Type of project(required): 1.2 1 am a employer with 6 employees(full and/or part-time).* 7. ❑New construction 1[]1 ant a sole proprietor or partnership and have no employees working for me in 8. []Remodeling any capacity.[No workers'comp.insurance required.] 9. El Demolition 3.[]l ant a homeowner doing all work myself.(No workns'comp.insurance required.]t 10 Q Building addition 4.❑i am a homeowner and will be hiring contractors to conduct all work on illy property. t will ensure that all contractorseither have workers'compensation insurance or are sole I I.r_1 Electrical repairs or additions proprietors with no employees. 12.[]Plumbing repairs or additions 5.❑i am a general contractor and I have hired the sub-contractors listed int the attached sheet. These sub-contractors have employees and have workers'com14.�r Other-Solarp.insurance.. 13.❑Roof repairs 6,[:]We arc a corporation and its officers have exercised their right of exemption per MGL C. 152.§ (4),and we have no employees.(No workers'comp.insurance required.] 'Any applicant that checks box R I must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they arc doing all work and then hire outside contractors must submit a new affidavit indicating such. Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees.they must provide their workers'comp,policy number. 1 atm an employer that is providing workers'compensation insuiwtice fo►•my employees. Below is the policy and job site information. Insurance Company Name:Berkley Insurance Policy#or Self--ins.Lic.#:MAARP301229 Expiration Date: 2/1/2019 Job Site Address: 704 Fairway Village City/State/Zip: L.eeds,MA 01053 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under ViGL c. 152, §25A is a criminal violation punishable by a fine up to S1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the Violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under,4firge pains and penalties of pert' the information provided above is tr•ug and torr'ct. J Signature: /` Date: L/ � C� / / V Phone#:413-584-68'44' :413-584- 844 Official use onit�. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: City of Northampton Massachusetts Ate. ti "3 DEPARTMENT OF BUILDING INSPECTIONS y 212 Main Street •Municipal Building Northampton, MA 01060 Debris Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. The debris from construction work being performed at: 704 Fairway Village (Please print house number and street name) Is to be disposed of at: Valley Recycling. (235 Easthampton Rd, MA 01060) (Please print name and location of facility) Or will be disposed of in a dumpster onsite rented or leased from: Valley Solar. (POB 60627, MA 01062) (Company Name and Address) Signature 6VPermit Applicant or Owner Date If, for any reason, the debris will not be disposed of as indicated, the Applicant or Owner shall notify the Building Department as to the location where the debris will be disposed. F152 S. Broad St. 1J.71�✓t�l Lansdale, PA 19446 (21 5)361-8040 August 30, 2018 Valley Solar 340 Riverside Dr Northampton, MA 01062 RE: Viele Residence 704 Fariway Village, Leeds, MA 01053 Client Project#: 4524VIE PFE Project#: 183839 On behalf of Valley Solar, PennFusion Engineering LLC(PFE) performed a structural analysis of the roof at the above referenced location. The purpose of our analysis was to determine if the existing roof system is structurally sufficient to support the new photovoltaic moudles in addition to the code required design loads. Our analysis is based on the information provided by Valley Solar and is isolated only to the areas where the modules are intended to be placed. System Specifications: Total System Size: 12.41 kW/DC Panel Specs: (34) LG Solar- LG365Q1 C-A5 Inverter Specs: (34) Enphase- IQ6+ Racking System: SnapNRack -Series 100 LIL The modules are to be located on the following roof planes: Mounting Rafter Rafter Horizontal Collar Collar Tie Sheathing Shingle Number of Ceiling Plane Size Spacing Span Ties Spacing Type Shingle Layers Profile 1 Truss 24" 24ft. 3in. N/A 0" CDX 112" Asphalt 1 Flat Shingles 2 Truss 24" 14ft. 6in. N/A 0" CDX 1/2" Asphalt 1 Flat Shingles The roof design has been analyzed in accordance with the 2015 International Residential Code and Massachusettes Amendments 9th Edition with design loads as follows: Ground Snow(Pg): 40 psf Wind Speed (V): 117 mph Mounting Plane 1 It has been determined by this office that the roof, as specified above, is adequate to support the new PV modules in addition to the code required design loading. Attach the module rail brackets to the roof with 5/16" lag bolts at 48 on center maximum. Provide a minimum of 2" of penetration into the wood members. Mounting Plane 2 It has been determined by this office that the roof, as specified above, is adequate to support the new PV modules in addition to the code required design loading. Attach the module rail brackets to the roof with 5/16" lag bolts at 48 on center maximum. Provide a minimum of 2"of penetration into the wood members. This office has determined that the installation of the PV System as specified above will meet the structural requirements of the 2015 International Residential Code with Massachusettes Amendments 9th Edition and ASCE7-10 when installed in accordance with the manufacture's instructions. If you have any questions regarding this analysis, please feel free to contact us. J' -A OF P,fA,. Best Regards, Penn Fusion Engineering LLC O ANDRE-el DQVE%C `-" O LEO\E NO 53041,- Andrew D. Leone, P.E. .a Principal Is SSS -AL � � REVENUE GRADE METER(N) ° ° R MAIN ELECTRICAL PANEL(E) U w (12)LG 365Q1C-A5 SOLAR PV PANELS(N) y SOLAR AC COMBINER BOX(N) (12)ENPHASE IQ6PLUS MIRC04NVERTERS(N) ° - � U UTILITY METER(E) o ° ° A>o_ AC DISCONNECT SWITCH(N v ¢o 51 1 oaN r J r (22)ENPHASE IQ6PLUS MIRC04NVERTERS(N)— (22) N)(22)LG 365Q1C-A5 SOLAR PV PANELS(N) <o zQ w a w w t 70 t > 70w m e m; N �a Z g g w H Proiect Components: rn PV Solar Arr_. P Racking:Snap N Rack Series 100 Panels:(34)LG365Q1C-A5 Micro-Inverters:(34)Enphase IQ6plus-72-2-US Utility Client: ° E m N External wall of building: Claudia Viele AC disconnect switchz° r–m Utility meter o> 704 Fairway Village tY a Leeds MA 01053 Internal wall of building: m AC Combiner o° Main electrical Panel N Revenue Grade Production Meter a fn zm (E)Existing (N)New �o a� TMs plan Is ffxr propdeteryw product of Vetley Home/mprovemw t fnc.(VHI),d is delivered for Me Ilmltetl entl exclusive purpose of supporting the contract bid of VHl,end customer agrees that the elements oWs plan sbelf not be repubhow or prey twin any iomr for the purpose of enebling or supporo'ng the worN of wripehrg prgecf convecfwa xdhout Me permissbn of,end compensetbn paid fo.VHI. C O O p M � O O C (D f 7 � M � O X 0 d O 7 a .y F'ti s 1 e ye r N S s:. tea, i y .t' Valley Solar LLC 340 Riverside Drive SITE NAME Claudia Viele SCALE.SEE VIEW SHEET NUMBER PO Box 60627 1 Northampton PLOT LINES SITE ADDRESS 704 Fairway Village DATE'.Wedre y. MA 01062 1 413.584.8844 Leeds,MA 1 5 haat 2018 www.ValleySolar.Solar SYSTEM SIZE 12.24 kWDC/9.52kWAC LR.B DRAwNLW By Labelina Schedule Eauioment Schedule0 F] Inverter Trip Settinas: M Inverter TRIP settings are set in the inverter per the ISO NE g P 1.PV ARRAY(Series 100) 1 CAUTION!AC VOLTAGE SRD and ESB 756 Section 7.6.11. Snap N Rack Roof Mount System 2 WARNING!PHOTOVOLTAIC POWER SOURCE DEVICE DEFAULT DEFAULT Pickups and 2.SOLAR PV MODULE(LG365Q1C-A5) 3 SOLAR PV AC COMBINER BOX PICKUP CLEARING TIME Clearing Times (34) LG 365W panels s m a 4 SOLAR PV AC PRODUCTION METER 3 DC/AC MICROINVERTER(IQ6+-72-2-US) 8 5 PV SYSTEM AC DISCONNECT Rated AC Output Current:31.59AAC SETTING (seconds) Adhere to (34)Enphase IQ6+ $ Nominal Operating Voltage:240V AC (simplified defaults Required 4.J BOX(0786-3R5) a s o from section 7.6.11) w o a lts(Yes/ Soladeck Pass-through enclosure (reflective) No): 5.AC COMBINER(XAM1-120-B) 7 WARNING!ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH Under Frequency 56.5 Hz 0.16 YES Enphase Envoy S production RGM,20A Breaker/branch v LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN 6 AC DISCONNECT(DU222RB) 3 POSITION (81 U) 60A 240VAC(adjacent to utility meter) m m y 8 WARNING BUSBAR IS ENERGIZED FROM 2 SOURCES UTILITY Under Frequency 58.5 Hz 300 YES 7.GENERATION METER(GE 1-210+) m—N�N GRID AND PHOTOVOLTAIC SYSTEM (Btu) ° ( ) Revenue Grade Meter 9 WARNING!INVERTER OUTPUT CONNECTION DO NOT Over Frequency 61.2 Hz 300 YES 8.SERVICE PANEL o a Op £ RELOCATE THIS OVERCURRENT DEVICE (810) 200A MAIN,200A BUS,40A Inverter OCPD v LL 10 SOLAR PV 9.UTILITY METER(221 121 57) v a 11 WARNING!UTILITY METER ENERGIZED BY 2 SOURCES Over Frequency 62.0 Hz 0.16 YES o N 120/240V,1 PH,3W (81 O) a ————————————————————— a � Under Voltage 50%of Nominal 1.1 YES AC Disco urchin 10' in (27) of the utllllg meter \ o w a I I Under Voltage 88%of Nominal 2 YES Q w (27) To/From a _ n � Q W� } 11 2 IL I E I o Over Voltage(59) 110%of Nominal 2 YES Utility N v u 2 Over Voltage(59) 120%of Nominal 0.16 YES �I\ q N BRANCH CIRCUIT IX I UTILITY § IN BRANCH CIRCUIT s �� � t00kWh <Q $ I H •H H +H Hi ♦H I AC Disco Q Q �c I N N N H H N N N I W❑ 131 M3 AL Ilj 2 Q H I 1 xHHW-s I z V a 1 (3) 10 Lt N L2 8 _ I ( 1Lis 5 J 3 ell- 8 IN me W LU MICROINVERTERS I o $ I IN BRANCH CIRCUIT w m � b 4 I o EN 6 I I - H Rr3M I m o o n I N N N N N N I I _ r t00kWh m I W e J m I I 10 5 MAIN SERVICE PANEL 1 iV d u I ").cu -HHN I I A°couer+ER BOX p I 12 GEC ( I Houee GEG I R o I 1 I B45EMENT _ > MBRANCH CIRC I - Ia I _ _ + IN BRANCH CIRCUIT - t I L------ --- ----------------J �I �ii I (2)Y12 - I (3)- a —2 In .0 um OCPD Calculations: .� N N N N Nt N ° I (2)#12 ecc cu as'w°E Breakers sized according to Continuous output current x 1.25 ^,y a ( I 2 cu Ecc (NEC 210.19(A)(1)(a)).IQ6+Microinverter Max Output=1.17A �� a m (1 (NEC s I H n H r EGC x 34 x1.25=39.78A Therefore 40A OCPD required ( a yr (9 LG . Life's Good i mom 000011100� NOON ,0000■ 000000000M LG NeON R The LG NeON®R is a high-power luxury solar panel featuring O ���� newly developed Back Contact TechnologyT"".The advanced I C q US6 cell structure locates all of the module's electrodes on the pVE back side of the panel,minimizing power loss and boosting efficiency. Enhanced Warranties •� High Power Output LG offers a 25-year product warranty for LG NeONO R in The LG NeOW R has been designed to significantly addition to an enhanced performance warranty.After 25 enhance its output,making it efficient even in limited years,LG NeON®R is guaranteed to produce at least 88.4% spaces, of its initial power output. Roof Aesthetics ® Outstanding Durability LG NeON`,R has been designed with aesthetics in mind: With its newly reinforced frame design,LG NeON"R can the lack of any electrodes on the front creates an endure a front load up to 6000 Pa,and a rear load up to improved,modern aesthetic. 5400 Pa. %•� Improved Performance on Sunny Days Near Zero LID (Light Induced Degradation) LG NeON R now performs better on sunny days,thanks to16 The n-type cells used in LG NeON11 R have almost no its improved temperature coefficient. boron.This leads to less LID right after installation. About LG Electronics LG Electronics is a global player who has been committed to expanding its capacity,based on solar energy business as its future growth engine.We embarked on a solar energy source research program in 1985, supported by LG Group's rich experience in semi-conductor,LCD,chemistry,and materials industry.We successfully released first Mono X®series to the market in 2010,which were exported to 32 countries in the following 2 years,thereafter.In 2013,NeONTM(previously known as Mono X®NeON)&2015 NeON2 with CELLO technology won"Intersolar Award",which proved LG is the leader of innovation in the industry. LG NeON ' R MM Mechanical Properties Electrical Properties(STC*) Cells 6 x 10 Module 365 Cell Vendor LG Maximum Power(Pmax) _365 Cell Type_ Monocrystalline/N-type MPP Voltage(Vmpp) 36.7 Cell Dimensions 161.7 x 161.7 mm/6 inches MPP Current(Impp) 9.95 Dimensions(L x W x H) 1700 x 1016 x 40 mm _ — Open Circuit Voltage(Voc) 42.8 - -__— x -----inch Short Circuit Current(Isc) 10.8 Front Load _ 6,0O01"a/125 psf Module Efficiency 21.1 Rear Load i___ 5,4001"a/113 psf Operating Temperature -40-+90 Weight -- 18.5 kg/40_79 Ib _ Maximum System Voltage 1000 Connector Type _ MC4 Maximum Series Fuse Rating i 20 Junction Box — _ IP68 with 3 Bypass Diodes Power Tolerance(%) 0-+3 — Length of Cables _—_—_ 1000 mm x 2 ea •STC(Standard Tet Condition)Irradiance 1,000 W/m',Ambient Temperature 25 T,AM 15 Glass Tempered Glass with AR Coating The nameplate po ie.r output is measured and determined by LG Electronics at its sole and absolute discretion. -- 'The typical charge in module efficiency at 200 W/m'in relation to 1000 W/m'is-2.0%. Frame— T Anodized Aluminium Electrical Properties(NOCT*) Certifications and Warranty _Module _365 Certifications IEC 61215,IEC 61730-1/-2 Maximum Power(Pmax) 275 UL 1703 --, --� MPP Voltage(Vmpp)_ --__ ----=—__36.6 — _- - IEC 61701(Salt mist corrosion test) MPP Current(Impp) — 7.51 IEC 62_716(Ammonia corrosion test) Open Circuit Voltage(Voc) — _-- —40.2 --— — I50 9001 Short Circuit Current(Isc) 8.70 Module Fire Performance(USA) Type 1 NOCT(Nominal Operating Cell Temperature)Irradiance 800 Win',ambient temperature 20 Y,wind speed 1 m/s Fire Resistance Class(CANADA) Class C(ULC/ORD C1703) Product Warranty 25 years Output Warranty of Pmax Linear warranty** Dimensions(mm/in) ^7)1st year 98%,2)After 1st year 0 4%annual degradation,3)25 years 88.4% Temperature Characteristics NOCT 44 t 3'C Pmpp -0.30%/'C S Voc -0.24%/'C Isc 0.04%/'C Characteristic Curves - --vom"e lv) 'The distance between the renter of the mounting/grounding holes. LG North Amenca Solar Business Team Product specifications are subject to change without notice. �,L° LG Electronics U.S.A.Inc DS-TI-72-W-G-P-EN-60630 Y Lifes Good 1000 Sylvan Ave,Englewood Cliffs,N107632 Copyright©2017 LG Electronics.All rights reserved Innovation for a Better Life LY Contact Ig.solara(Nge.mm 01/01!2017 www.igsolarusa.com a The high-powered smart grid-ready Enphase Enphase IQ 6 Micro' and Enphase IQ 6+ MicroT" IQ 6 and IQ 6+ dramatically simplify the installation process while achieving the highest efficiency for module-level M icroinverters power electronics. Part of the Enphase IQ System,the IQ 6 and IQ 6+ Micro integrate seamlessly with the Enphase IQ Envoy"", Enphase Q Aggregator'", Enphase IQ BatteryT", and the Enphase Enlighten'" monitoring and analysis software. The IQ 6 and IQ 6+ Micro extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install Lightweight and simple ig Faster installation with improved two-wire cabling k Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing w ' "t Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with fixed power factor,voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) U� *The IQ 6+Micro is required to support 72-cell modules "'� ENPHASE To learn more about Enphase offerings,visit enphase.com %./ Enphase IQ 6 and IQ 6+ Microinverters INPUT DATA(DC) IQ6-60-2-US IQ6PLUS-72-2-US Commonly used module pairings' 195W-330W+ 235W-400W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 62V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16V-62V Min/Max start voltage 22V/48V 22 V/62 V Max DC short circuit current(module Isc) 15A 15A Overvoltage class DC port II II DC port backfeed under single fault 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 6 Microinverter IQ 6+Microinverter Peak output power 240 VA 290 VA Maximum continuous output power 230 VA 280 VA Nominal(L-L)voltage/rangez 240 V/211-264 V 208 V/183-229 V 240 V/211-264 V 208 V/183-229 V Maximum continuous output current 0.96 A 1.11 A 1.17 A 1.35 A Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz Power factor at rated power 1.0 1.0 Maximum units per 20 A(L-L)branch circuit 16(240 VAC) 13(240 VAC) 14(208 VAC) 11 (208 VAC) Overvoltage class AC port III 111 AC port backfeed under single fault 0 A 0 A Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type MC4 locking type Dimensions(WxHxD) 219 mm x 191 mm x 37.9 mm(without bracket) Weight 1.29 kg(2.84 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power line Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690- Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. To learn more about Enphase offerings,visit enphase.com (�)2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. �./ E N P H A S E. 2018-01-25 REVISION: SNAPNRACK SERIES 100 RACKING SYSTEM TYPICAL ROOF LAYOUT _ NOTES: -STANDARD LAG BOLT SPEC ASSUMES — 5/16" LAG BOLTS WITH 2.5" _ EMBEDMENT IN ROOF STRUCTURAL MEMBERS/RAFTERS -TORQUE ALL5' HARDWARE TO THE FOLLOWING: ROOF RAFTERS OR - SILVER S.S. 10-16 FT-LBS STRUCTURAL MEMBERS - BLACK S.S. 7-9 FT-LBS RAIL CAN MOUNT TO EITHER SIDE OF POST(UPSLOPE vs. DOWNSLOPE) - FOR UNEVEN ROOF SURFACES, USE SNAPNRACK MODULE UP TO TWO LEVELING SPACERS PER L ` I MID CLAMPS MODULE TO OVERHEXCEEANG FOOT OR STANDOFF. SEE DRAWING "STANDARD RAIL LEVELING" FOR OR MANUFACTURER'S DETAILS AND LIMITATIONS RECOMMENDATIONS) // / MODULE OVERHANG STANDOFFS ARE BOLTED INTO ROOF RAFTERS OR STRUCTURAL MEMBER I / ZZ /// / / zz /// "RAIL SPAN" // /// DISTANCE BETWEEN ROOF ATTACHMENTS "RAIL END OVERHANG" (NOT TO EXCEED 34%OF ACCEPTABLE RAIL SPAN) MAINSTREAM ENERGY CORP. DESIGNER: G McPheeters SCALE: DNS PART NUMBER' DESCRIPTION: REV ��p�J�Q�- m DRAFTER: D Ryan S100 D05 SERIES 100 TYPICAL LAYOUT F (1}�OOlIQ94fl09�f m. m APPROVED BY: DATE: 120113