CS Roof Girder CalcsCS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 1 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG1 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: -3.50 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/240 live, L/180 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 4' 0.00" 0 61 Live Replacement Uniform (PLF) Top 0' 0.00" 4' 0.00" 0 61 Live Replacement Uniform (PLF) Top 0' 0.00" 4' 0.00" 149 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 4' 0.00" 149 0 Snow Replacement Uniform (PLF) Top 4' 0.00" 4' 2.75" 0 59 Live Replacement Uniform (PLF) Top 4' 0.00" 4' 2.75" 0 63 Live Replacement Uniform (PLF) Top 4' 0.00" 4' 2.75" 145 0 Snow Replacement Uniform (PLF) Top 4' 0.00" 4' 2.75" 155 0 Snow Replacement Uniform (PLF) Top 4' 2.75" 4' 8.63" 0 59 Live Replacement Uniform (PLF) Top 4' 2.75" 4' 8.63" 0 61 Live Replacement Uniform (PLF) Top 4' 2.75" 4' 8.63" 145 0 Snow Replacement Uniform (PLF) Top 4' 2.75" 4' 8.63" 149 0 Snow Replacement Uniform (PLF) Top 4' 8.63" 5' 8.63" 0 56 Live Replacement Uniform (PLF) Top 4' 8.63" 5' 8.63" 0 56 Live Replacement Uniform (PLF) Top 4' 8.63" 5' 8.63" 136 0 Snow Replacement Uniform (PLF) Top 4' 8.63" 5' 8.63" 136 0 Snow Replacement Uniform (PLF) Top 5' 8.63" 6' 8.63" 0 48 Live Replacement Uniform (PLF) Top 5' 8.63" 6' 8.63" 0 48 Live Replacement Uniform (PLF) Top 5' 8.63" 6' 8.63" 119 0 Snow Replacement Uniform (PLF) Top 5' 8.63" 6' 8.63" 119 0 Snow Replacement Uniform (PLF) Top 6' 8.63" 7' 8.63" 0 41 Live Replacement Uniform (PLF) Top 6' 8.63" 7' 8.63" 0 41 Live Replacement Uniform (PLF) Top 6' 8.63" 7' 8.63" 101 0 Snow Replacement Uniform (PLF) Top 6' 8.63" 7' 8.63" 101 0 Snow Replacement Uniform (PLF) Top 7' 8.63" 8' 8.63" 0 34 Live Replacement Uniform (PLF) Top 7' 8.63" 8' 8.63" 0 34 Live Replacement Uniform (PLF) Top 7' 8.63" 8' 8.63" 84 0 Snow Replacement Uniform (PLF) Top 7' 8.63" 8' 8.63" 84 0 Snow Replacement Uniform (PLF) Top 8' 8.63" 9' 8.63" 0 27 Live Replacement Uniform (PLF) Top 8' 8.63" 9' 8.63" 0 27 Live Replacement Uniform (PLF) Top 8' 8.63" 9' 8.63" 66 0 Snow Replacement Uniform (PLF) Top 8' 8.63" 9' 8.63" 66 0 Snow Replacement Uniform (PLF) Top 9' 8.63" 10' 8.63" 0 20 Live Replacement Uniform (PLF) Top 9' 8.63" 10' 8.63" 0 20 Live Replacement Uniform (PLF) Top 9' 8.63" 10' 8.63" 49 0 Snow Replacement Uniform (PLF) Top 9' 8.63" 10' 8.63" 49 0 Snow Replacement Uniform (PLF) Top 10' 8.63" 11' 8.63" 0 13 Live Replacement Uniform (PLF) Top 10' 8.63" 11' 8.63" 0 13 Live Replacement Uniform (PLF) Top 10' 8.63" 11' 8.63" 31 0 Snow Replacement Uniform (PLF) Top 10' 8.63" 11' 8.63" 31 0 Snow Replacement Uniform (PLF) Top 11' 8.63" 12' 2.63" 0 7 Live Replacement Uniform (PLF) Top 11' 8.63" 12' 2.63" 0 7 Live Replacement Uniform (PLF) Top 11' 8.63" 12' 2.63" 18 0 Snow Replacement Uniform (PLF) Top 11' 8.63" 12' 2.63" 18 0 Snow Replacement Uniform (PLF) Top 12' 2.63" 13' 0.00" 0 2 Live Replacement Uniform (PLF) Top 12' 2.63" 13' 0.00" 0 2 Live Replacement Uniform (PLF) Top 12' 2.63" 13' 0.00" 7 0 Snow Replacement Uniform (PLF) Top 12' 2.63" 13' 0.00" 7 0 Snow 1 2 3 4 2 12 8 2 8 0 6 12 13 0 0 CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 2 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 384# -- 2 4' 2.750" Wall SPF Plate (425psi) N/A 3.672" 2731# -- 3 12' 5.250" Wall SPF Plate (425psi) N/A 1.500" 508# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1# 268# 116# 2 5# 1880# 852# 3 1# 340# 168# Design spans 4' 0.063" 8' 6.625" 0' 7.000" (right cant) Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1170.'# 12233.'# 9% 8.71' Total Load D+S Negative Moment 1701.'# 12233.'# 13% 4.23' Total Load D+S Shear 1013.# 4541.# 22% 4.24' Total Load D+S TL Deflection 0.0268" 0.5701" L/999+ 8.71' Total Load D+S LL Deflection 0.0183" 0.4276" L/999+ 8.71' Total Load S TL Defl., Rt. -0.0062" 0.2000" 2L/999+ 13' Total Load D+S LL Defl., Rt. -0.0042" 0.2000" 2L/999+ 13' Total Load S Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 3 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG2 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 14.2 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 7' 2.75" 0 69 Live Replacement Uniform (PLF) Top 0' 0.00" 7' 2.75" 170 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 15' 5.75" 0 69 Live Replacement Uniform (PLF) Top 0' 0.00" 15' 5.75" 170 0 Snow Replacement Uniform (PLF) Top 7' 2.75" 15' 5.75" 0 70 Live Replacement Uniform (PLF) Top 7' 2.75" 15' 5.75" 171 0 Snow 1 2 15 5 12 15 5 12 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 2.432" 3618# -- 2 15' 5.750" Wall SPF Plate (425psi) N/A 2.436" 3624# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 7# 2498# 1119# 2 7# 2502# 1122# Design spans 14' 8.500" Product: 1-3/4x14 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 13315.'# 33390.'# 39% 7.74' Total Load D+S Shear 3048.# 10706.# 28% 14.36' Total Load D+S TL Deflection 0.3239" 0.7354" L/544 7.74' Total Load D+S LL Deflection 0.2236" 0.4903" L/789 7.74' Total Load S Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 4 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG3 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 9.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 2' 3.00" 0 51 Live Replacement Uniform (PLF) Top 0' 0.00" 2' 3.00" 174 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 9' 0.00" 0 45 Live Replacement Uniform (PLF) Top 0' 0.00" 9' 0.00" 148 0 Snow Replacement Uniform (PLF) Top 2' 3.00" 9' 0.00" 1 64 Live Replacement Uniform (PLF) Top 2' 3.00" 9' 0.00" 212 0 Snow 1 2 9 0 0 9 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 1972# -- 2 9' 0.000" Wall SPF Plate (425psi) N/A 1.500" 2051# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 4# 1485# 487# 2 4# 1545# 507# Design spans 8' 7.750" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 4407.'# 16051.'# 27% 4.5' Total Load D+S Shear 1673.# 7265.# 23% 8.39' Total Load D+S TL Deflection 0.1183" 0.4323" L/876 4.5' Total Load D+S LL Deflection 0.0891" 0.2882" L/999+ 4.5' Total Load S Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 5 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG4 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 2.47 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/240 live, L/180 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 1' 1.25" 0 1 Live Replacement Uniform (PLF) Top 0' 0.00" 1' 1.25" 5 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 1' 1.25" 1 63 Live Replacement Uniform (PLF) Top 0' 0.00" 1' 1.25" 209 0 Snow Replacement Uniform (PLF) Top 1' 1.25" 1' 9.75" 0 5 Live Replacement Uniform (PLF) Top 1' 1.25" 1' 9.75" 13 0 Snow Replacement Uniform (PLF) Top 1' 1.25" 2' 6.25" 0 3 Live Replacement Uniform (PLF) Top 1' 1.25" 2' 6.25" 6 0 Snow Replacement Uniform (PLF) Top 1' 9.75" 3' 2.69" 0 9 Live Replacement Uniform (PLF) Top 1' 9.75" 3' 2.69" 22 0 Snow Replacement Uniform (PLF) Top 2' 6.25" 3' 11.19" 0 8 Live Replacement Uniform (PLF) Top 2' 6.25" 3' 11.19" 19 0 Snow Replacement Uniform (PLF) Top 3' 2.69" 4' 7.69" 0 14 Live Replacement Uniform (PLF) Top 3' 2.69" 4' 7.69" 34 0 Snow Replacement Uniform (PLF) Top 3' 11.19" 5' 4.19" 0 13 Live Replacement Uniform (PLF) Top 3' 11.19" 5' 4.19" 31 0 Snow Replacement Uniform (PLF) Top 4' 7.69" 6' 0.63" 0 19 Live Replacement Uniform (PLF) Top 4' 7.69" 6' 0.63" 47 0 Snow Replacement Uniform (PLF) Top 5' 4.19" 6' 0.13" 0 16 Live Replacement Uniform (PLF) Top 5' 4.19" 6' 0.13" 40 0 Snow Replacement Uniform (PLF) Top 6' 0.13" 6' 4.00" 0 18 Live Replacement Uniform (PLF) Top 6' 0.13" 6' 4.00" 44 0 Snow Replacement Uniform (PLF) Top 6' 0.63" 7' 5.63" 0 24 Live Replacement Uniform (PLF) Top 6' 0.63" 7' 5.63" 59 0 Snow Replacement Uniform (PLF) Top 6' 4.00" 7' 9.00" 0 21 Live Replacement Uniform (PLF) Top 6' 4.00" 7' 9.00" 52 0 Snow Replacement Uniform (PLF) Top 7' 5.63" 8' 10.63" 0 29 Live Replacement Uniform (PLF) Top 7' 5.63" 8' 10.63" 72 0 Snow Replacement Uniform (PLF) Top 7' 9.00" 9' 1.94" 0 26 Live Replacement Uniform (PLF) Top 7' 9.00" 9' 1.94" 64 0 Snow Replacement Uniform (PLF) Top 8' 10.63" 10' 3.56" 0 34 Live Replacement Uniform (PLF) Top 8' 10.63" 10' 3.56" 84 0 Snow Replacement Uniform (PLF) Top 9' 1.94" 10' 6.94" 0 31 Live Replacement Uniform (PLF) Top 9' 1.94" 10' 6.94" 77 0 Snow Replacement Uniform (PLF) Top 10' 3.56" 11' 8.56" 0 39 Live Replacement Uniform (PLF) Top 10' 3.56" 11' 8.56" 96 0 Snow Replacement Uniform (PLF) Top 10' 6.94" 11' 8.56" 0 36 Live Replacement Uniform (PLF) Top 10' 6.94" 11' 8.56" 88 0 Snow Replacement Uniform (PLF) Top 11' 8.56" 12' 0.25" 0 38 Live Replacement Uniform (PLF) Top 11' 8.56" 12' 0.25" 94 0 Snow Replacement Uniform (PLF) Top 11' 8.56" 12' 6.44" 2 1 Live Replacement Uniform (PLF) Top 12' 0.25" 12' 6.44" 0 40 Live Replacement Uniform (PLF) Top 12' 0.25" 12' 6.44" 97 0 Snow 1 2 0 9 9 10 11 0 0 9 14 12 6 7 2 7 0 CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 6 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 9.562" Wall SPF Plate (425psi) N/A 1.500" 879# -- 2 11' 8.562" Wall SPF Plate (425psi) N/A 1.500" 1104# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 2# 612# 267# 2 3# 753# 351# Design spans 0' 9.750" (left cant) 11' 1.750" 0' 5.375" (right cant) Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2201.'# 12233.'# 17% 6.8' Total Load D+S Negative Moment 91.'# 12233.'# 0% 0.8' Total Load D+S Shear 762.# 4541.# 16% 11.17' Total Load D+S TL Deflection 0.0983" 0.7431" L/999+ 6.34' Total Load D+S LL Deflection 0.0663" 0.5573" L/999+ 6.34' Total Load S TL Defl., Lt. -0.0211" 0.2000" 2L/924 0' Total Load D+S LL Defl., Lt. -0.0142" 0.2000" 2L/999+ 0' Total Load S TL Defl., Rt. -0.0134" 0.2000" 2L/801 12.54' Total Load D+S LL Defl., Rt. -0.0091" 0.2000" 2L/999+ 12.54' Total Load S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 7 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG5 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 2.47 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/240 live, L/180 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 1' 1.25" 0 1 Live Replacement Uniform (PLF) Top 0' 0.00" 1' 1.25" 5 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 1' 1.25" 1 63 Live Replacement Uniform (PLF) Top 0' 0.00" 1' 1.25" 209 0 Snow Replacement Uniform (PLF) Top 1' 1.25" 1' 9.19" 1 64 Live Replacement Uniform (PLF) Top 1' 1.25" 1' 9.19" 214 0 Snow Replacement Uniform (PLF) Top 1' 1.25" 1' 9.75" 0 5 Live Replacement Uniform (PLF) Top 1' 1.25" 1' 9.75" 13 0 Snow Replacement Uniform (PLF) Top 1' 9.19" 3' 2.19" 0 5 Live Replacement Uniform (PLF) Top 1' 9.19" 3' 2.19" 12 0 Snow Replacement Uniform (PLF) Top 1' 9.75" 3' 2.69" 0 9 Live Replacement Uniform (PLF) Top 1' 9.75" 3' 2.69" 22 0 Snow Replacement Uniform (PLF) Top 3' 2.19" 4' 7.13" 0 10 Live Replacement Uniform (PLF) Top 3' 2.19" 4' 7.13" 24 0 Snow Replacement Uniform (PLF) Top 3' 2.69" 4' 7.69" 0 14 Live Replacement Uniform (PLF) Top 3' 2.69" 4' 7.69" 34 0 Snow Replacement Uniform (PLF) Top 4' 7.13" 6' 0.13" 0 15 Live Replacement Uniform (PLF) Top 4' 7.13" 6' 0.13" 37 0 Snow Replacement Uniform (PLF) Top 4' 7.69" 6' 0.63" 0 19 Live Replacement Uniform (PLF) Top 4' 7.69" 6' 0.63" 47 0 Snow Replacement Uniform (PLF) Top 6' 0.13" 7' 5.13" 0 20 Live Replacement Uniform (PLF) Top 6' 0.13" 7' 5.13" 49 0 Snow Replacement Uniform (PLF) Top 6' 0.63" 7' 5.63" 0 24 Live Replacement Uniform (PLF) Top 6' 0.63" 7' 5.63" 59 0 Snow Replacement Uniform (PLF) Top 7' 5.13" 8' 10.06" 0 25 Live Replacement Uniform (PLF) Top 7' 5.13" 8' 10.06" 61 0 Snow Replacement Uniform (PLF) Top 7' 5.63" 8' 10.63" 0 29 Live Replacement Uniform (PLF) Top 7' 5.63" 8' 10.63" 72 0 Snow Replacement Uniform (PLF) Top 8' 10.06" 10' 3.06" 0 30 Live Replacement Uniform (PLF) Top 8' 10.06" 10' 3.06" 74 0 Snow Replacement Uniform (PLF) Top 8' 10.63" 10' 3.56" 0 34 Live Replacement Uniform (PLF) Top 8' 10.63" 10' 3.56" 84 0 Snow Replacement Uniform (PLF) Top 10' 3.06" 11' 8.00" 0 35 Live Replacement Uniform (PLF) Top 10' 3.06" 11' 8.00" 86 0 Snow Replacement Uniform (PLF) Top 10' 3.56" 11' 8.56" 0 39 Live Replacement Uniform (PLF) Top 10' 3.56" 11' 8.56" 96 0 Snow Replacement Uniform (PLF) Top 11' 8.00" 12' 0.25" 0 38 Live Replacement Uniform (PLF) Top 11' 8.00" 12' 0.25" 94 0 Snow Replacement Uniform (PLF) Top 11' 8.56" 12' 6.44" 0 43 Live Replacement Uniform (PLF) Top 11' 8.56" 12' 6.44" 106 0 Snow Replacement Uniform (PLF) Top 12' 0.25" 12' 6.44" 0 40 Live Replacement Uniform (PLF) Top 12' 0.25" 12' 6.44" 97 0 Snow 1 2 0 9 9 11 8 14 12 6 7 2 7 0 CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 8 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 9.562" Wall SPF Plate (425psi) N/A 1.500" 1095# -- 2 12' 6.438" Wall SPF Plate (425psi) N/A 1.527" 1135# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 2# 774# 321# 2 2# 777# 358# Design spans 0' 9.750" (left cant) 11' 7.125" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2536.'# 12233.'# 20% 7.41' Total Load D+S Negative Moment 91.'# 12233.'# 0% 0.8' Total Load D+S Shear 844.# 4541.# 18% 11.58' Total Load D+S TL Deflection 0.1233" 0.7729" L/999+ 6.47' Total Load D+S LL Deflection 0.0837" 0.5797" L/999+ 6.47' Total Load S TL Defl., Lt. -0.0260" 0.2000" 2L/750 0' Total Load D+S LL Defl., Lt. -0.0176" 0.2000" 2L/999+ 0' Total Load S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 9 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG6 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.8 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 2' 0.00" 0 27 Live Replacement Uniform (PLF) Top 0' 0.00" 2' 0.00" 75 0 Snow Replacement Uniform (PLF) Top 2' 0.00" 4' 0.00" 0 47 Live Replacement Uniform (PLF) Top 2' 0.00" 4' 0.00" 117 0 Snow 1 2 3 1 9 4 2 2 12 4 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Girder SPF Plate (425psi) N/A N/A 43# -- 2 1' 9.250" Wall SPF Plate (425psi) N/A 1.500" 308# -- 3 4' 0.000" Girder SPF Plate (425psi) N/A N/A 138# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 0# 30# 13# 2 1# 212# 96# 3 0# 94# 44# Design spans 1' 6.250" 1' 11.750" Product: Spruce-Pine-Fir #2 2 x 12 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 56.'# 5306.'# 1% 2.96' Total Load D+S Negative Moment 60.'# 5306.'# 1% 1.77' Total Load D+S Shear 40.# 3493.# 1% 1.78' Total Load D+S LL Deflection 0.0010" 0.0660" L/999+ 2.86' Total Load S TL Deflection 0.0010" 0.0990" L/999+ 2.86' Total Load D+S Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 10 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG7 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.8 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 2' 0.00" 0 48 Live Replacement Uniform (PLF) Top 0' 0.00" 2' 0.00" 118 0 Snow Replacement Uniform (PLF) Top 2' 0.00" 4' 0.00" 5 2 Live 1 2 3 2 2 12 1 9 4 4 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Girder SPF Plate (425psi) N/A N/A 145# -- 2 2' 2.750" Wall SPF Plate (425psi) N/A 1.500" 197# -- 3 4' 0.000" Girder SPF Plate (425psi) N/A N/A -- -23# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 0# 100# 46# 2 6# 128# 69# 3 3# -19# -3# Design spans 1' 11.750" 1' 6.250" Product: Spruce-Pine-Fir #2 2 x 12 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 61.'# 5306.'# 1% 1.04' Total Load D+S Negative Moment 47.'# 5306.'# 0% 2.23' Total Load D+S Shear 35.# 3493.# 0% 1.34' Total Load D+S LL Deflection 0.0010" 0.0660" L/999+ 1.14' Total Load S TL Deflection 0.0010" 0.0990" L/999+ 1.14' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 11 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG8 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 3.12 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/240 live, L/180 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.8 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 1' 1.81" 27 8 Snow Replacement Uniform (PLF) Top 0' 0.00" 1' 5.69" 22 7 Snow Replacement Uniform (PLF) Top 1' 1.81" 2' 5.19" 0 2 Live Replacement Uniform (PLF) Top 1' 1.81" 2' 5.19" 11 0 Snow Replacement Uniform (PLF) Top 1' 5.69" 3' 0.88" 0 4 Live Replacement Uniform (PLF) Top 1' 5.69" 3' 0.88" 18 0 Snow Replacement Uniform (PLF) Top 2' 5.19" 3' 8.56" 0 6 Live Replacement Uniform (PLF) Top 2' 5.19" 3' 8.56" 24 0 Snow Replacement Uniform (PLF) Top 3' 0.88" 4' 8.06" 0 9 Live Replacement Uniform (PLF) Top 3' 0.88" 4' 8.06" 32 0 Snow Replacement Uniform (PLF) Top 3' 8.56" 4' 11.94" 0 10 Live Replacement Uniform (PLF) Top 3' 8.56" 4' 11.94" 36 0 Snow Replacement Uniform (PLF) Top 4' 8.06" 6' 3.31" 0 14 Live Replacement Uniform (PLF) Top 4' 8.06" 6' 3.31" 47 0 Snow Replacement Uniform (PLF) Top 4' 11.94" 6' 3.31" 0 14 Live Replacement Uniform (PLF) Top 4' 11.94" 6' 3.31" 47 0 Snow Replacement Uniform (PLF) Top 6' 3.31" 7' 6.69" 0 18 Live Replacement Uniform (PLF) Top 6' 3.31" 7' 6.69" 59 0 Snow Replacement Uniform (PLF) Top 6' 3.31" 7' 10.50" 0 18 Live Replacement Uniform (PLF) Top 6' 3.31" 7' 10.50" 61 0 Snow Replacement Uniform (PLF) Top 7' 6.69" 8' 10.00" 0 21 Live Replacement Uniform (PLF) Top 7' 6.69" 8' 10.00" 70 0 Snow Replacement Uniform (PLF) Top 7' 10.50" 9' 5.69" 0 22 Live Replacement Uniform (PLF) Top 7' 10.50" 9' 5.69" 74 0 Snow Replacement Uniform (PLF) Top 8' 10.00" 10' 1.38" 0 25 Live Replacement Uniform (PLF) Top 8' 10.00" 10' 1.38" 81 0 Snow Replacement Uniform (PLF) Top 9' 5.69" 11' 0.94" 0 27 Live Replacement Uniform (PLF) Top 9' 5.69" 11' 0.94" 88 0 Snow Replacement Uniform (PLF) Top 10' 1.38" 11' 4.75" 0 28 Live Replacement Uniform (PLF) Top 10' 1.38" 11' 4.75" 92 0 Snow Replacement Uniform (PLF) Top 11' 0.94" 12' 11.63" 0 31 Live Replacement Uniform (PLF) Top 11' 0.94" 12' 11.63" 102 0 Snow Replacement Uniform (PLF) Top 11' 4.75" 12' 11.63" 0 32 Live Replacement Uniform (PLF) Top 11' 4.75" 12' 11.63" 103 0 Snow 1 2 12 11 10 12 11 10 3 4 7Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 682# -- 2 12' 11.625" Girder SPF Plate (425psi) N/A N/A 1221# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1# 491# 192# 2 3# 897# 324# Design spans 12' 8.438" CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 12 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Product: Spruce-Pine-Fir #2 2 x 12 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2941.'# 5306.'# 55% 7.55' Total Load D+S Shear 931.# 3493.# 26% 12.06' Total Load D+S LL Deflection 0.1221" 0.6350" L/999+ 6.53' Total Load S TL Deflection 0.1676" 0.8467" L/909 6.53' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 13 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG9 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: -3.12 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/240 live, L/180 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.8 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 1' 6.88" 0 32 Live Replacement Uniform (PLF) Top 0' 0.00" 1' 6.88" 103 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 1' 10.69" 0 31 Live Replacement Uniform (PLF) Top 0' 0.00" 1' 10.69" 102 0 Snow Replacement Uniform (PLF) Top 1' 6.88" 2' 10.25" 0 28 Live Replacement Uniform (PLF) Top 1' 6.88" 2' 10.25" 92 0 Snow Replacement Uniform (PLF) Top 1' 10.69" 3' 5.94" 0 27 Live Replacement Uniform (PLF) Top 1' 10.69" 3' 5.94" 88 0 Snow Replacement Uniform (PLF) Top 2' 10.25" 4' 1.63" 0 25 Live Replacement Uniform (PLF) Top 2' 10.25" 4' 1.63" 81 0 Snow Replacement Uniform (PLF) Top 3' 5.94" 5' 1.13" 0 22 Live Replacement Uniform (PLF) Top 3' 5.94" 5' 1.13" 74 0 Snow Replacement Uniform (PLF) Top 4' 1.63" 5' 4.94" 0 21 Live Replacement Uniform (PLF) Top 4' 1.63" 5' 4.94" 70 0 Snow Replacement Uniform (PLF) Top 5' 1.13" 6' 8.31" 0 18 Live Replacement Uniform (PLF) Top 5' 1.13" 6' 8.31" 61 0 Snow Replacement Uniform (PLF) Top 5' 4.94" 6' 8.31" 0 18 Live Replacement Uniform (PLF) Top 5' 4.94" 6' 8.31" 59 0 Snow Replacement Uniform (PLF) Top 6' 8.31" 7' 11.69" 0 14 Live Replacement Uniform (PLF) Top 6' 8.31" 7' 11.69" 47 0 Snow Replacement Uniform (PLF) Top 6' 8.31" 8' 3.56" 0 14 Live Replacement Uniform (PLF) Top 6' 8.31" 8' 3.56" 47 0 Snow Replacement Uniform (PLF) Top 7' 11.69" 9' 3.06" 0 10 Live Replacement Uniform (PLF) Top 7' 11.69" 9' 3.06" 36 0 Snow Replacement Uniform (PLF) Top 8' 3.56" 9' 10.75" 0 9 Live Replacement Uniform (PLF) Top 8' 3.56" 9' 10.75" 32 0 Snow Replacement Uniform (PLF) Top 9' 3.06" 10' 6.44" 0 6 Live Replacement Uniform (PLF) Top 9' 3.06" 10' 6.44" 24 0 Snow Replacement Uniform (PLF) Top 9' 10.75" 11' 5.94" 0 4 Live Replacement Uniform (PLF) Top 9' 10.75" 11' 5.94" 18 0 Snow Replacement Uniform (PLF) Top 10' 6.44" 11' 9.81" 0 2 Live Replacement Uniform (PLF) Top 10' 6.44" 11' 9.81" 11 0 Snow Replacement Uniform (PLF) Top 11' 5.94" 12' 11.63" 22 7 Snow Replacement Uniform (PLF) Top 11' 9.81" 12' 11.63" 27 8 Snow 1 2 12 11 10 12 11 10 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Girder SPF Plate (425psi) N/A N/A 1221# -- 2 12' 11.625" Wall SPF Plate (425psi) N/A 1.500" 682# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 3# 897# 324# 2 1# 491# 192# Design spans 12' 8.438" CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 14 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Product: Spruce-Pine-Fir #2 2 x 12 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2941.'# 5306.'# 55% 5.42' Total Load D+S Shear 931.# 3493.# 26% 0.3' Total Load D+S LL Deflection 0.1221" 0.6350" L/999+ 6.44' Total Load S TL Deflection 0.1676" 0.8467" L/909 6.44' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 15 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG10 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 10.2 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 11' 0.00" 1 135 Live Replacement Uniform (PLF) Top 0' 0.00" 11' 0.00" 336 0 Snow 1 2 11 0 0 11 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 2460# -- 2 11' 0.000" Wall SPF Plate (425psi) N/A 1.500" 2460# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 5# 1716# 744# 2 5# 1716# 744# Design spans 10' 2.750" Product: Spruce-Pine-Fir #2 2 x 12 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 6292.'# 9154.'# 68% 5.5' Total Load D+S Shear 2009.# 5240.# 38% 10.1' Total Load D+S LL Deflection 0.1106" 0.3410" L/999+ 5.5' Total Load S TL Deflection 0.1585" 0.5115" L/774 5.5' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 15 % This member has been designed in accordance with NDS 2005 CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 16 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG11 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 21.3 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 8' 1.00" 1 135 Live Replacement Uniform (PLF) Top 0' 0.00" 8' 1.00" 336 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 9' 8.50" 0 15 Live Replacement Uniform (PLF) Top 0' 0.00" 9' 8.50" 51 0 Snow Replacement Uniform (PLF) Top 8' 1.00" 12' 11.25" 0 19 Live Replacement Uniform (PLF) Top 8' 1.00" 12' 11.25" 91 0 Snow Replacement Uniform (PLF) Top 9' 8.50" 15' 9.25" 0 9 Live Replacement Uniform (PLF) Top 9' 8.50" 15' 9.25" 33 0 Snow Replacement Uniform (PLF) Top 12' 11.25" 17' 8.50" 0 19 Live Replacement Uniform (PLF) Top 12' 11.25" 17' 8.50" 90 0 Snow Replacement Uniform (PLF) Top 15' 9.25" 19' 11.13" 0 28 Live Replacement Uniform (PLF) Top 15' 9.25" 19' 11.13" 89 0 Snow Replacement Uniform (PLF) Top 17' 8.50" 19' 11.13" 0 19 Live Replacement Uniform (PLF) Top 17' 8.50" 19' 11.13" 90 0 Snow 1 2 19 11 2 19 11 2 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.827" 4076# -- 2 19' 11.125" Wall SPF Plate (425psi) N/A 1.500" 2528# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 8# 2839# 1237# 2 5# 1796# 733# Design spans 19' 2.125" Product: 1-3/4x14 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 14865.'# 52088.'# 28% 8.06' Total Load D+S Shear 3426.# 16060.# 21% 0.4' Total Load D+S TL Deflection 0.4013" 0.9589" L/573 9.7' Total Load D+S LL Deflection 0.2817" 0.6392" L/816 9.7' Total Load S Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 17 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG13 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: -5.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/240 live, L/180 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 3.4 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 6' 5.50" 2 1 Snow Replacement Uniform (PLF) Top 0' 0.00" 6' 5.50" 23 7 Snow Point (LBS) Top 0' 4.63" 112 54 Snow Point (LBS) Top 6' 5.50" 112 54 Snow 1 2 6 5 8 1 0 0 7 5 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 278# -- 2 6' 5.500" Wall SPF Plate (425psi) N/A 1.500" 282# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Snow Dead 1 189# 89# 2 189# 93# Design spans 6' 6.938" 1' 1.000" (right cant) Product: Spruce-Pine-Fir #2 2 x 12 1 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 170.'# 2653.'# 6% 3.42' Total Load D+S Negative Moment 2.'# 2076.'# 0% 6.46' Total Load D Shear 72.# 1747.# 4% 5.55' Total Load D+S LL Deflection 0.0037" 0.3290" L/999+ 3.42' Total Load S TL Deflection 0.0053" 0.4387" L/999+ 3.42' Total Load D+S LL Defl., Rt. -0.0019" 0.2000" 2L/999+ 7.46' Total Load S TL Defl., Rt. -0.0028" 0.2000" 2L/999+ 7.46' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 18 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG14 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 5.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/240 live, L/180 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 3.4 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 1' 0.00" 7' 5.50" 2 1 Snow Replacement Uniform (PLF) Top 1' 0.00" 7' 5.50" 23 7 Snow Point (LBS) Top 1' 0.00" 112 54 Snow Point (LBS) Top 7' 0.88" 112 54 Snow 1 2 1 0 0 6 5 8 7 5 8 3 1 5Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 1' 0.000" Wall SPF Plate (425psi) N/A 1.500" 282# -- 2 7' 5.500" Wall SPF Plate (425psi) N/A 1.500" 278# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Snow Dead 1 189# 93# 2 189# 89# Design spans 1' 1.000" (left cant) 6' 6.938" Product: Spruce-Pine-Fir #2 2 x 12 1 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 170.'# 2653.'# 6% 4.04' Total Load D+S Negative Moment 2.'# 2076.'# 0% 1' Total Load D Shear 72.# 1747.# 4% 1.01' Total Load D+S LL Deflection 0.0037" 0.3290" L/999+ 4.04' Total Load S TL Deflection 0.0053" 0.4387" L/999+ 4.04' Total Load D+S LL Defl., Lt. -0.0019" 0.2000" 2L/999+ 0' Total Load S TL Defl., Lt. -0.0028" 0.2000" 2L/999+ 0' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 19 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG16 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 12.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/240 live, L/180 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.8 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 0' 9.00" 23 7 Snow Replacement Uniform (PLF) Top 0' 0.00" 1' 0.00" 23 7 Snow Replacement Uniform (PLF) Top 0' 9.00" 6' 9.00" 4 1 Snow Replacement Uniform (PLF) Top 1' 0.00" 10' 6.00" 23 7 Snow Replacement Uniform (PLF) Top 6' 9.00" 10' 6.00" 23 7 Snow Point (LBS) Top 0' 8.13" -20 0 Snow Point (LBS) Top 0' 8.13" 3 -0 Live Point (LBS) Top 6' 10.50" 0 17 Live Point (LBS) Top 6' 10.50" 41 0 Snow 1 2 10 6 0 10 6 0 10 6 0Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 267# -- 2 10' 6.000" Wall SPF Plate (425psi) N/A 1.500" 348# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 3# 167# 114# 2 0# 215# 134# Design spans 13' 9.438" Product: Spruce-Pine-Fir #2 2 x 12 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 754.'# 5306.'# 14% 5.73' Total Load D+S Shear 197.# 3493.# 5% 9.63' Total Load D+S LL Deflection 0.0314" 0.6894" L/999+ 5.24' Total Load S TL Deflection 0.0516" 0.9192" L/999+ 5.24' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 20 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG17 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 12.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/240 live, L/180 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.8 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 6' 9.00" 23 7 Snow Replacement Uniform (PLF) Top 0' 0.00" 9' 11.75" 23 7 Snow Replacement Uniform (PLF) Top 6' 9.00" 9' 11.75" 4 1 Snow Point (LBS) Top 6' 7.50" 0 49 Live Point (LBS) Top 6' 7.50" 97 0 Snow 1 2 9 11 12 9 11 12 9 11 12Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 381# -- 2 9' 11.750" Wall SPF Plate (425psi) N/A 1.500" 381# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 0# 238# 144# 2 0# 235# 146# Design spans 13' 0.250" Product: Spruce-Pine-Fir #2 2 x 12 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 967.'# 5306.'# 18% 5.45' Total Load D+S Shear 237.# 3493.# 6% 8.67' Total Load D+S LL Deflection 0.0367" 0.6511" L/999+ 4.99' Total Load S TL Deflection 0.0588" 0.8682" L/999+ 4.99' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 21 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG18 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: -12.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/240 live, L/180 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.8 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 3' 2.75" 4 1 Snow Replacement Uniform (PLF) Top 0' 0.00" 9' 11.75" 23 7 Snow Replacement Uniform (PLF) Top 3' 2.75" 9' 11.75" 23 7 Snow Point (LBS) Top 3' 3.63" 0 52 Live Point (LBS) Top 3' 3.63" 100 0 Snow 1 2 9 11 12 9 11 12 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 385# -- 2 9' 11.750" Wall SPF Plate (425psi) N/A 1.500" 382# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 0# 237# 148# 2 0# 238# 144# Design spans 13' 0.250" Product: Spruce-Pine-Fir #2 2 x 12 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 972.'# 5306.'# 18% 4.53' Total Load D+S Shear 240.# 3493.# 6% 0.39' Total Load D+S LL Deflection 0.0369" 0.6511" L/999+ 4.99' Total Load S TL Deflection 0.0591" 0.8682" L/999+ 4.99' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 22 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG19 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 5.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/240 live, L/180 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.8 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 8' 0.00" 23 7 Snow Replacement Uniform (PLF) Top 0' 0.00" 10' 5.50" 23 7 Snow Replacement Uniform (PLF) Top 8' 0.00" 10' 5.50" 5 1 Snow Replacement Uniform (PLF) Top 8' 0.00" 10' 5.50" 0 53 Live Replacement Uniform (PLF) Top 8' 0.00" 10' 5.50" 174 0 Snow Point (LBS) Top 0' 4.63" 0 0 Snow Point (LBS) Top 8' 0.00" 3 367 Live Point (LBS) Top 8' 0.00" 917 0 Snow 1 2 10 5 8 10 5 8 4 4 5Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 653# -- 2 10' 5.500" Wall SPF Plate (425psi) N/A 1.500" 1725# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1# 457# 196# 2 3# 1235# 490# Design spans 10' 5.938" Product: Spruce-Pine-Fir #2 2 x 12 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2984.'# 5306.'# 56% 8' Total Load D+S Shear 1354.# 3493.# 38% 9.59' Total Load D+S LL Deflection 0.0728" 0.5248" L/999+ 5.71' Total Load S TL Deflection 0.1029" 0.6997" L/999+ 5.71' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 10 7-26-16 8:01am 23 of 23 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG20 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: -12.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/240 live, L/180 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.8 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 2' 5.50" -23 -7 Snow Replacement Uniform (PLF) Top 0' 0.00" 2' 5.50" 5 1 Snow Replacement Uniform (PLF) Top 0' 0.00" 2' 5.50" 0 53 Live Replacement Uniform (PLF) Top 0' 0.00" 2' 5.50" 71 20 Snow Replacement Uniform (PLF) Top 0' 0.00" 2' 5.50" 174 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 10' 5.50" 23 7 Snow Replacement Uniform (PLF) Top 2' 5.50" 10' 5.50" 23 7 Snow Point (LBS) Top 2' 5.50" 3 367 Live Point (LBS) Top 2' 5.50" 917 0 Snow Point (LBS) Top 10' 0.88" 0 0 Snow Point (LBS) Top 10' 0.88" 0 0 Snow 1 2 10 5 8 10 5 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.536" 1959# -35# 2 10' 5.500" Wall SPF Plate (425psi) N/A 1.500" 703# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 3# 1368# 591# 2 1# 473# 236# Design spans 13' 8.375" Product: Spruce-Pine-Fir #2 2 x 12 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 3210.'# 5306.'# 60% 2.46' Total Load D+S Negative Moment 23.'# 5306.'# 0% 1.84' Total Load D+S Shear 1123.# 3493.# 32% 0.39' Total Load D+S LL Deflection 0.1302" 0.6850" L/999+ 4.74' Total Load S TL Deflection 0.1883" 0.9133" L/872 4.74' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005