Loading...
CS 1st Foor Girder CalcsCS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 6 7-26-16 8:50am 1 of 2 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG9 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 2.8 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 5.50" 8' 11.50" 27 7 Live Replacement Uniform (PLF) Top 0' 5.50" 17' 0.00" 27 7 Live Replacement Uniform (PLF) Top 8' 11.50" 17' 0.00" 27 7 Live 1 2 0 5 8 16 6 8 17 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 5.500" Wall SPF Plate (425psi) N/A 1.500" 568# -- 2 17' 0.000" Wall SPF Plate (425psi) N/A 1.500" 567# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 435# 133# 2 435# 132# Design spans 0' 5.500" (left cant) 16' 3.875" Product: 11-7/8" AJS 20 1 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2313.'# 4400.'# 52% 8.62' Total Load D+L Shear 567.# 1490.# 38% 0.46' Total Load D+L Cant. Shear, Lt 1.# 1341.# 0% 0.45' Total Load D End Reaction 568.# 1215.# 46% 0.46' Total Load D+L TL Deflection 0.3153" 0.8161" L/621 8.62' Total Load D+L LL Deflection 0.2421" 0.5441" L/809 8.62' Total Load L TL Defl., Lt. -0.0253" 0.2000" 2L/434 0' Total Load D+L LL Defl., Lt. -0.0194" 0.2000" 2L/566 0' Total Load L Control: Pos. Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Left cantilever allowable shear is for joist only CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 6 7-26-16 8:50am 2 of 2 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG10 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 0' 5.50" 0 57 Live Replacement Uniform (PLF) Top 0' 2.75" 0' 5.50" 804 208 Live Replacement Uniform (PLF) Top 0' 5.50" 2' 5.50" 804 208 Live Replacement Uniform (PLF) Top 0' 5.50" 8' 11.50" 27 7 Live Replacement Uniform (PLF) Top 0' 5.50" 8' 11.50" 27 7 Live Replacement Uniform (PLF) Top 0' 5.50" 8' 11.50" 0 57 Live Replacement Uniform (PLF) Top 2' 5.50" 8' 11.50" 85 0 Snow Replacement Uniform (PLF) Top 2' 5.50" 8' 11.50" 390 203 Live Point (LBS) Top 2' 3.75" 7 514 Live Point (LBS) Top 2' 3.75" 834 0 Snow 1 2 0 5 8 8 6 0 8 11 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 5.500" Wall SPF Plate (425psi) N/A 5.825" 4332# -- 2 8' 11.500" Wall SPF Plate (425psi) N/A 4.237" 3151# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 2717# 840# 1615# 2 1902# 516# 1249# Design spans 0' 5.500" (left cant) 8' 1.375" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS Minimum 5.82" bearing required at bearing # 1 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 6870.'# 10637.'# 64% 4.11' Even Spans D+L Negative Moment 33.'# 10637.'# 0% 0.46' Total Load D+L Shear 2942.# 3948.# 74% 0.47' Total Load D+L TL Deflection 0.1705" 0.4057" L/571 4.52' Even Spans D+0.75(L+S) LL Deflection 0.1019" 0.2705" L/955 4.52' Even Spans 0.75(L+S) TL Defl., Lt. -0.0324" 0.2000" 2L/339 0' Even Spans D+0.75(L+S) LL Defl., Lt. -0.0195" 0.2000" 2L/564 0' Even Spans 0.75(L+S) Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160%