Loading...
16A-020 (16) 205 FAIRWAY VLG BP-2019-0089 GIs#: COMMONWEALTH OF MASSACHUSETTS Man.Block: 16A-020 CITY OF NORTHAMPTON Lot:.000 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Categorv, SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2019-0089 Project# JS-2019-000139 Est.Cost: $24900.00 Fee $75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: VALLEY SOLAR LLC 077279 Lot Size(sa.ft.): Owner: ANDREW DONALD G& zoomw URA(102)/WP(17)/WSP(15)/ Applicant. VALLEY SOLAR LLC AT: 205 FAIRWAY VLG Applicant Address: Phone: Insurance: PO BOX 60627 (413) 584-8844 WC FLORENCEMA01062 ISSUED ON.712312018 0:00.00 TO PERFORM THE FOLLOWING WORK:18 PANEL ROOF MOUNTED SOLAR 6.57 KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy S enature• FeeType: Date Paid: Amount: Building 723/2018 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner 1 Department use only rNortcry City of Northampton Status of Permit: Building Department Curb Cut/Driveway,Permit t, r 212 Main Street Sewer/Septic Availability hampton, Room 100 Water/Well Availability MA 01060 Two Sets of Structural Plans phone 413-587-1240 Fax 413-587-1272 Plol/Site Plans Other Specify APPLICATION TO CONSTRUCT,A LISH A ONE OR TWO FAMILY DWELLING SECTION I -SITE INFORMATION &a 1 — / 1.1 Property Address l: JUL 2 0 2018 his section W be completed by office a05 �QIrI tJQ Ulll ()T Map Lot n,30 Unit Leed J, �n N53 J DEPT OF RTHAMDINCINSpECTIONe C NORTHAMPTON,INS Overlay District Elm St District Ca District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: DbnQLOCAncl Sandra AncAreLy a air oflla Name(Print) Current! ailingAddres - 4,Z -Lfs- Teiepnone Signature ti 2.2 Aufficirrilt2d.Ai Valley Solar LLC PO Box 60627, Florence, MA 01062 Name(Pring Ganem Mailing Address. 413-584-8844 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed bermit applicant 1. Building (a)Building Permit Fee 2. Electrical (b)Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) ?7 5.Fire Protection 6. Total=(1 +2+3+4+5) 1 Check Number o'1 /y This Section For Official Use Only Building Permit Number Date Issued' aa Signature: ` °�''t'L. 7120(1g Building Gommissioner/Inspeclor of Buildings Date Ihasbrouck @ northamptonma.gov info�a valleysolar.solar EMAIL ADDRESS (REQUIRED; CON ACTO ) f Section 4. :ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning Th.,column ,,be filled In by Banding ixpanmenf LotSize Frontage Setbacks Front Sid. L: R: L: R Rear Building Height Bldg. Square Footage Open Space Footage lL.frna minus bldg&pnved arkin #ofParking Spaces Fill: me&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DONT KNOW O YES O IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DONT KNOW O YES O IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO O DONT KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Downy signs exist on the property? YES O NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO O IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavafiou,or filling)over I acre or is it pan of a common plan that will disturb over 1 acre? YES O NO O IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check II applicable1 New House ❑ Addition ❑ Replacement Wlnclows Alteration(s) Roofing Dr Doors D Accessory Bldg. ❑ Demolition ❑ New Signs (OI Decks (p Siding Other[ Solar Brief Descnpption f Proposetl r n �I Work. I(17+ol11a4rIm l7 Il I nnP 42f O0 Lr Uni nrraw. sgwrn ,51ze6.5T1 Alteration of existing bedroom_Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet so.If New house and or addition to existing houi complete the followina: a. Use of building: One Fari Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? I. Method of heating? Fireplaces or Woodsloves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands?_Yes No. Is construction within 100 yr. floodplain_Yes_No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank_ City Sewer_ Private well_ City water Supply_ SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, HCl�rn And(ek) as Owner of the subject prop rty hereby authorize Valley Solar LLC to act on my behalf,in all matters relative to work authorized by this building permit application. Signi of Owner Gf.[ Date Valley Solar LLC as GwcsNAulhorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. p Print Name Signature of CwnerlAgent Date a SECTION S-CONSTRUCTION SERVICES 8.1 Licensed Construe on Suoervlsor: ` ` 1� ..r���✓� Not Applicable ❑ Noma of Licanae Hold., SteVtX1 PC Si,r�-cI` lJ' 1 License Number Q,GS ernes RqRDSouM6mPton, m41 oral3 Cl-)- M 9 P-qq Add Expiration Date i 1413-5'0 -18S4W 61� {ao2-� re SignatuTelephone 9.Reaistered Home Improvement Contractor: Not Applicable ❑ Company Name Registration Number Valley Solar LLC 186338 Address Expiration Date PO Box 60627, Florence MA 01062 Telephone 413-584-8844 10/27/18 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152, 225C(5)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit vnll result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... No...... ❑ - - The Commonwealth of Massachusetts Department of Industrial Accidents 1 Congress Street, Suite 100 Boston, MA 02114-2017 wllnttinaJF.gi t'lidia \Corkers'Compensation Insurance.Affidavit: Builders/Conti'actors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING.AUTHORITY. Applicant inf rmation Please PrintLegibly Nance (Busncss/Olyanrzanon/Ind...doa):Valley Solar LLC Address:340 Riverside Dr., PO Box 60627 City/Static/Zip:Florence, MA O1062 Phone#:413-584-8844 \rr you an employer?Chani No apprnpnnle bot,: Type of project(required): I. ✓❑ an,a emnlover with 6 .nni lPolliodrorynrl-rimcl' 7. F1 New Coltinvetion 2❑Ian :ole propricmr or pnrmcrship and m Locmployce moiling Iii 8, ❑ m Reodeling aw,machy.INneorkot loan,. smmneccreCnigdl 3❑lan,, eir,00a'ncrdomgallonica in)sNf IN.,vob... comp.humanccmemrtd.l' 1 ❑Bunting ion 5.0 l am a lmmeo,vnor and-11 be hilm trnoors m eoddnaua work odor Iwill !0❑Building addition genu ypmperly rt,thin aommcmrsolhcr lla,c enlxerz'rolnpoll:ak,n m:arancc orarc.om ILE]Electrical repairs or additions prdnde,ors"ah no cowle"c.. 12E]Plumbin g,epiro,ur additions SIhma allb—ommraonramu dir Hired mesao-cak no, nlml nm dnacho-1 zhet. 13.❑Runfropairs Th—wbwnoauoa l,nc rn,ploy and hive ovdmz nnP_ ,minocc 6Wc arc a c corporationand roernccaInv :<enooic+cd,nemla pNIGLc 14.Q Other Solar I s_5 hal,and an,pldynes.INd eorl:ers olno annall mmr.noc aqui,nd.7 nya,dcvidimaheek:hnsalcompadvmlodpoi... ..... rHon mhos,binnm ban otndoindicating mm oy adoing all work and then him ouraldc connaa .n mnmaaabmnn dlee andmt indicating sudl. !Conan.,that check this Lux oras mmehed an addnlmwLheel elmxang the name orthe wogddai emu and na¢,.I¢ther or not Ihos<mitic hag anplot,ws ICJ¢subrn mors hhvr clnplupti.theym apmadd lhan aliko,'con,.pohcnnoall- /am an ernplol'ei that is providing norkers'conrpennatlmr irnuranre fm'nm employees. Befmv is t/repalicy and tol ire information. Insurance Company Name Berkley Insurance Pali y 4 of Selparis Lic,i MAARP301229 Eapirztiun Dalt, 2/1/2019 Joh Sire Address. 205 Fairway Village ray:Slate/4, Leeds, MA 01053 Attach a copy of the workers'compensation policy declaration page(showing the policy number and eaph ation date). Failure to seao'e coverage as required under MGL c. 152. §25A is a ain,inal violation punishable by a fine up at SL500 00 and/or one-year Imprisonment,as well as civil penalties in the for of a STOP WORK ORDER and a fine ofup to 5250.00 a day against the violator. A copy of dais statement may be forwarded to the Office of Investigations of the DIA for insurance mexrage verification. 1 da hereby certify ////d//re�g acus and p/end/rtltics of perj the inforvnntiarr provided above is ave rtud rat/'rf,cr. Signature 7/x //' p. U�% L7/ / .413-58444 Phone#. Official use wily. Do not write in this are.,to be completed br cior or anon affciaf City ar Town: Permil/License It Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.Cim/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contac[Person: Phone 4: City of Northampton a s , ` Massachusetts t: LB.PAR�T OF BUILDING INSPECTIONS 212 Main Stret *Municipal Building ® Cm Northampton, t 01060 Debris Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. The debris from construction work being performed at: 205 Fairway Village Leeds, MA 01053 (Please print house number and street name) Is to be disposed of at: Valley Recycling. (235 Easthampton Rd, MA 01060) (Please print name and location of facility) Or will be disposed of in a dumpster onsite rented or leased from: Valley Solar. (POB 60627, MA 01062) (Company Name and Addresrs))� — I./, Signature of Permit Applicant or Owner Date If, for any reason, the debris will not be disposed of as indicated, the Applicant or Owner shall notify the Building Department as to the location where the debris will be disposed. 15 V�iir7 FUSION Lansd2 S. Broad 4 F r ale, PA 194466 (2 15)361-8040 July 19, 2018 Valley Solar 340 Riverside Or Northampton, MAO 1062 RE: Wyner Residence 205 Fairway Villagge,Leeds, MA 01053 Client Project#: 205WYNE PFE Project#. 183158 On behalf of Valley Solar, Penn Fusion Engineering LLC(PEE)performed a structural analysis of the roof at the above referenced location.The purpose of our analysis was to determine if the existing roof system is structurally sufficient to support the new photovoltaic moudles in addition to the code required design loads.Our analysis is based on the information provided by Valley Solar and is isolated only to the areas where the modules are intended to be placed. System Specifications: Total System Size. 6.57 kW/DC Panel Specs: (I8)LG Solar- LG365Q1 C-A5 Inverter Specs: (18) Enph ase - IQ6+ Racking System: Snap N Rack - Series 100 J The modules are to be located on the Following roof plane: Mounting Rafter Rafter Horizontal Collar Collar The Sheathing Shingle Number of Ceiling Plane Size Spacing Span Ties Spacing Type Shingle Layers Profile I Truss 24" 24ft.Gin. N/A 0" COX 1/2" Asphalt I Flat Shingles The roof design has been analyzed in accordance with the 2015 International Residential Code and Massachusettes Amendments 9th Edition with design loads as follows'. Ground Snow(PT 40 psf Wind Speed(V): 120 mph Mounting Plane 1 It has been determined by this office that the roof,as specified above, is adequate to support the new PV modules in addition to the code required design loading. Attach the module rail brackets to the roof with 5/16"lag bolts at 48 on center maximum. Provide a minimum of 2"of penetration into the wood members. This office has determined that the installation of the PV System as specified above will meet the structural requirements of the 2015 Internacional Residential Code with Massachusettes Amendments 9th Edition and ASCE]-10 when installed in accordance with the manufacture's instructions. If you have any questions regarding this analysis, please feel free to contact us. OF br454.9 Rest Re Penn Fusioncion Engineering LLC lt)Vk J Andrew D. Leone, P.E. 41 Principal ryrc SSr[hA- ENG' B [ Y � 3 SOLAR AC COMBINER BOX IN) REVENUE GRADE METER(N) MAIN ELECTRICAL PANEL E) 8 �Rm 4 hit 4 (]B) NPHASE IQ6PLU5 MIRCCANVERTERS IN) URLITY METER(E) pp (9B)LG 365(IIGA5 SOLAR PV PANELS(N) [h AC DISCONNECT SWITCH(N) R N B9 ad ig Poiect Components: 4� Racking Snap IN Rack-Sal es 100 0 s a e V I Panels'(18)LG365Q10-AS o sa a S Micro-Inverters:(18)Enphase IQ6plus-72-2-US sg External wall of building'. UtIIHv Client AIR' AC disconnect switchj%z 1 gUtility meter Donald Andrew 38 e 205 Fairway Village A _$ nternalwell of build.ng. Leeds MA 01053 e AC Combiner e Main electrical Panel a I. Revenue Grade Production Meter ¢g Y (E)Existing $a (N)New £p s � 9 _ b p u s e !! s p 11 V 11 ILV Y e � B A all¢ uo 10821413 saoare a a oala — y ao m.soan lMonn.mp� PLOT LINES srtE woaEss ms—1.2, a6w vim " S lar Mnu,66iemasen.6eaa 6a rmw:IMyseY"Soln SVSiEM SIZE 65 I M�— @ Eauloment Schedule O Conduit&Conductor Schedule L � Label'na Schedule 11 1 PV ARRAY(Series 100) 1.SOLAR PV AC COMBINER BOX 1.(1)N6 CU RACK BOND GEC.IN FREE-AIR. 2SOLAR PV AC PRODUCTION METER E . Snap N Rack Roof Mount System 2.(2)2-wire O Cable,listed wlmicroinverters. y 2 SOLAR PV MODULE(LG365QiC-A51 E 3.PV SYSTEM AO DISCONNECT Outdoor rated -- 4.WARNING BUSBAR IS ENERGIZED FROM 2 (18) LG 365W panels 3.EH#12 CU THHN-2.(3); 6 CU bare ESC.IN SOURCES UTILITY GRID AND PHOTOVOLTAIC 3 DCIAC MICROINVERTER(IQ6t-72-2-US) 1/2'"MC SYSTEM (18) OX(D86-3R 4.(3)ifd AL SER.(1)#6 CU ESC. IN illMC p 4.J-BOX(0]86-3R5) 5.(3)II4 AL SER.(1)#6 CU EGG.IN illi"MC S.WARNING!INVERTER OUTPUT CONNECTION DO Soladeck Pass-through enclosure i NOT RELOCATE THIS OVERCURRENT DEVICE 6.(3)2d)AL SER. _ 6.SOLAR PV WARNING'UTILITY METER 5 AC COMBINER(MM1-120-B) 1.House GEC Enphase EnvoyS production ROM.20A Breaker/branch r ENERGIZED BY 2 SOURCES a 6-A 20VACNECT(DU222RB) =u 3 30A 240VAC IOME(adjacent to utility meter) GENERATION Grade METER(GE I-2100 Revenue Grade Meter B B SERVICE PANEL �� " \� 200A MAIN,200A BUS,30A Inverter OCPD b TolFrom 3 s s 9 UTILITY METER Ufliry @ 120/240V,1PH,3W T - € I� Q K� --------------------- --- -------- ----- z gg B y 5A ----- 1 I w¢ WU at I 9 I eapaas c 4 ap I x Wrt _ j§ I I w° 9 I i> I I I 9. 4F I 1 1 I S a g OCPD calculations: T �� Bmakert suetl a..c ngro mnllnuous outpN currtntr 125 (NEC 21019(A)(1)!A).'CBs M1ficm'mener Max OWpu1=1 PA F 3 x1ax125=26.925AThemfore36AOCPDmqulmd — It x x " ROOF ARRAY x " a HOUSE INTERIOR _ €g ———————————————— _-------__—__—_ -----_--_----_—___ (0 LG 0 . • . l,:r:,cl)od M . ON LG NeON R mmm P �)N .RIi I i, il.^1,1p Fk 11 .l1 n!,'1 ll lil 1-o11 60 cell f I I d II ;nl r l .I r l : o�E �' i!_1 o r I 1 10 1 1101111 .I IL J I r Inc YO . .- ._ ._.. IF [ nio,i J ..nr,r11 1 Ld I i Il'lfk IF I'll, 11 111ii nine1, F 11aatlIf"I l IF Irddrfi ,o(s. Enhanced Warranty •• High Powerl Output -M1si I f r I. I Aesthetic Roof �® Outstanding Durability I r • I . Better Performance on a Sunny Day Near Zero LID(Light Induced Degradation) G� r � li I IF LG NeON R Mechanical Properties Electrical Properties(STC•) Ccik M d le 365 4J1 Vrndor M um Power(Pmar) r m .- 11Tj,, Mop . _ - Voltage(V , )CeMPP Cm [(Im") ' olmorvons 0.,wv n) Ir. ." OP I-- (Voc). -- _ Sao,,C.curt Corm,0") 1, load M dole Efficient, Roar1oad a. - - OP abng Temperature , We'9dt F' __. _. Ma+mum Spm�n Volpge Conn er lnrlmu M rnIt—,Fuse Racing Innalnn Rnx 1 Sr .e a�b. p Tolerance(%) -. I enytM1 of Cubluc - '"' i Electrical Properties(NOCT•) Certifications and Warranty ,__ Modnlo 365 _nre Rrur,unr I � .., Mnx n Pnu r(Prnax) _ tut P.Val"',(0ep, _ MPP Cw rent olla") " OPin Crnrt Voltage ModuleF .lmm�ntrylBAJ �.� _ Fir,Re -fence 0.11(CANADA) I, Produo warranty o�rwc wa.l ann re Pm,, Dimensions(mm/in) Temperature Characteristics 1 -I WICT PmPP Va Characteristic Curves )I f eeea I ® LG o• o 0 The high-poweredsmart grid ready ��„„ '.. . P t§r.a.ae � . ._;"' and , i . ,.n,.1 Wit dramatically simplify the installation process while S` t� aS.S a 9 13,.- ` achieving the highest efficiency for module-level jy'gVr 7 ` f ; power electronics_ Part of the Enphase IQ System,the IQ 6 and IQ 6+ Micro integrate seamlessly with the Enphase IQ Envoy", Enphase Q Aggregator'", Enphase IQ Battery", and the Enphase Enlighten'" monitoring and analysis software- The IQ 5 and IQ 5+ Micro extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install L i9htv,,,ht aid sl,,pl, r ast ennsthllaboo ri Ii Improved two-wac rahLng Halt ,,ap,d shutdown.,,pliant an G 2014 &2-17, r Productive and Reliable Orr mvz,C for high pcweied 1,0 "elland 72-cele module= More than a million ho:us of tesrinq �* Class II double-nsulsed enclosure ULlisred Smart Grid Ready Complies with fixed power tach',voltage znd frequency rid,-through ,gnucmerrts Fematcly cpcares m respond to iiangln9 gn I requaements 1o.... chic for vary a,gild Urofl,l N11'111 ARul L1151i lo learn more about Enphase offerings,vsit enphase.com E N P H A S E EnphaseIQ 6 and IQ 6+ Microinverters INPUT DATA (DC) E 6-60-2-US IQ6PLU5-72-2-US ..0 It .ed moa l 0ngs2 l95N1 130W; <'35W-40C1N+ „gym ipVtib0liv 60-ce1111 lIxFonly 6p-DellarFj ,It PV morlole:. Mammunnu pul Dc'OVIa,, 48%, 6)V Peek powenrack'n9 xmltage DV-3:V V .15V Jperating =_n0e 16V 4a V 16V-62V Mn or Max alartvc lagr' 22V/48V '11V;o2V Max DC s hart circuitc ,rent(module Isc1 154 1sA �,ci.oltagr class llC if,, II II DCport backfeedander single faalt 0A 0A PV- l nfiquraforl 1x1 m0 Ic0ed anav;f edl1- 11DC11t _.,. reg..red, AVrideV Icl Tire,ex EApe: 1 I - cait OUTPUT DATA(AC) IQ 6 Microinverter IQ 6+MICrO1rlVerter Pgek Oetpat paver 24C VA 290VA MaAIFmM continuous oelput pe:vei 13P VA 280 VA N fn,,,I R-Ll voltage/range' 2T,V 121126CV 1108 it 181229V 240Vl2)1-t,4V /LNV If322'1 Maxmam ca,rfl, us cutput current 096A lilA II/A LE5A Neminal Oecuenry 60 He all H, I xtend,d 0e0uency r airy, 4T 58 14 47.0x 11, Poereriacto: avet,dpower 10 ID Mar `s Pert A L 11- anfhc t plcypr,) I dAci 14(202 VAGI 12c2 VAP Ov,r v0ltage class AC port III 81 A C port u a c kfeefi tm it er s og l e fault It 0A Power taVor(adlustablel 0leadmg OJ lagging 0 7leadrl 27agyng EFFICIENCY Iu1240 V W208 V 21240 V py08 V CEG weighted efaclency 970 9704 9702, 97U MECHANICAL DATA Ambient lemp,ratu[e range 4o°Cto+651 C R'Otive mri,dil. range 4e to'C 1 ( derssingl ..oaneclof lype MC,11(3ckin9 Eue Dlmensrarti lW,HxD) 219n-m r 191 mm x 37g nun iwlrho11 brackea r.,ignt 1 29 F9 G'8416.) _uolmg Nehral convection uoff,,, Approved fw wet lecano:v ve. FD1lul cn tL grew PD3 Lndpscre Class II double-inaalau, Fnvl real c,t,,o , J✓ elating NEMA',pe 6:out door FEATURES .,.mma..... on Power me Manolry Fnllghtcn Ma,t,,, aad M/ IC:hI'Invt ,nptlnns _t mpzflbie wnr EphaIF,10 Grvol Discoanccfmg it The At'arid DCepnilectxrs nave been evaluated and a ppmvod by UL for use asthe le ad-Lr+ak dlwaraed r,,,, ad by NEC 690. C:.crpllance CA Pule 21 IDI 1741 SAI IT 62109 I 1 L 741'1 FEC 1,1 FCC Part IF,Clase R, ICES-0003Class R, CAN/CSA-CD LW; 171-01 ih:I Frt J E u_Gs@d ',air Sial b pment and_( v.FIE NF 111 and NEC2cl 7 F,J n69oJ2.Ir,dC2ri-2015R 1,69-b8 Rapid 1 II ofP'/ nom' ° I-I and DC 1 11,411, ,,.r.r t,11-1accord .......V-tuel jr r. . l N fF,fxjrIedDC-AI I o See'Im c -nVavbil ty:alctlele at ', ✓cfjip 1 1 e t, i,v LI. _noJ,l P 1b!I_y. N nalvcltaye 10,e,t, d d brx,ondnon 'I regd,,,it of ihr„tl TC learn more about Enphase offerings,vlstt enphase.com _-`TENPHASE REVISION'. SNAPNRACK SERIES 100 RACKING SYSTEM TYPICAL ROOF LAYOUT NOTES: -STANDARD LAG BOLT SPK ASSUMES — — -- 5/16" LAG BOLTS WITH 2.5" EMBEDMENT IROOF STRUCTURAL --- MEMBERS/RAFTERS TORQUE ALL A" HARDWARE TO THE FOLLOWING: ROOF RAFTERS OR -SILVER S.S. 10-16 FT-IBS STRUCTURAL MEMBERS -BLACK S.S. 7-9 FT-LBS RAIL CAN MOUNT TO EITHER SIDE OF POST(UPSLOPE vs. DOWNSLOPE) - FOR UNEVEN ROOF SURFACES, USE MID CL ACK MODULE UP TO TWO LEVELING SPACERS PER L MID CLAMPS MODULE OVERHANG FOOT OR STANDOFF. SEE DRAWING I j'� (NOTANUFACTURERS EXCEED 30% "STANDARD RAIL LEVELING" FOR RE COMMENDATION ) DETAILS AND LIMITATIONS RECOMMENDATIONS) r i ' NODULE OVERHANG STANDOFFS ARE BOLTED INTO ROOF RAFTERS OR - STRUCTURAL MEMBER "RAIL SPAN' DISTANCE BETWEEN ROOF ATTACHMENTS "RAIL END OVERHANG"(NOT TO EXCEED ' 34%OF ACCEPTABLE RAIL SPAN) . _. NUIINSTREPM ENERGY CORP. OESIONER. 6MCPNaeler6 SCALE: DNS PART NUM9ER. OESLRIPTION. REV DRAFTER. 0Ryan .NATE 5100 D05 SERIES 100TVPIGAL LAYOUT F 61V' M®ouEBoag Sgm�auu® APPROVED BY _ 120113