32C-016 (5) 88 MAIN ST-NORTHAMPTON BP-2018-1306 GIS#; COMMONWEALTH OF MASSACHUSETTS Mao-.Block: 32C-016 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Cateeorv'renovation BUILDING PERMIT Permit# BP-2018-1306 Proiect# JS-2018-002326 Est.Cost: $75500.00 Fee: $529.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: JOHN KOSAKOWSKI 095492 Lot Size(so.R.): 4965.84 Owner: OIAN ZHU LI zonine�CB(100m/ Applicant: JOHN KOSAKOWSKI AT. 88 MAIN ST- NORTHAMPTON Applicant Address: Phone: Insurance: 113 LOUDVILLE RD (413) 200-7060 WC EASTHAMPTONMA01027 ISSUED ON:612212018 0:00:00 TO PERFORM THE FOLLOWING WORKRENOVATE TO CONVERT EXISTING SPACE INTO A RESTAURANT POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Sienature: FeeType: Date Paid: Amount: Building 6/22/2018 0:00:00 $529.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner File#BP-2018-1306 APPLICANT/CONTACT PERSON JOHN] JSAKOWSKI ADDRESS/PHONE 113 LOUDVILLE RD EASTHAMPTCD ;413)200-7060 PROPERTY LOCATION 88 MAIN ST-Nl RTHAMPTON MAP 32C PARCEL 016 001 ZONE CB(100)/ THIS SECTION FOR OFFIS IAL USE ONLY: PERMIT APPLICA TION CHECKLIST ENC SED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid T eof Construction: RENOVATE TO CONVE T EXI SPACE INTO A RESTAURANT New Construction Non Structural interior renovations Addition to E istine Accessory Structure Building Plans Included' Owner/Statement or License 095492 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFOYjMMATION PRESENTED: _eApproved_Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Platt AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit - Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition Delay n Signature of Bolding Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. w Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. Vemuml.7 Commercial Building Permit May 15,2000 4 Department use only C ty of Northampton S(atds'rofps" =- 5Bi iilding Department CurbG efiveway Permit 12 Main StreetSewer7S9ptIcAv00gbility Room 700 VJ'at�rtiYell AvalfaMllty DEPT OF BUILDING INSPECTIONS. NORTHAMPTON.MA 0100 ortampton, MA 01060 7wo'Sets of Structural Piens phone 413-587-1240 Fax 413-587-1272 Plotisea Plana 1, . .. OtherrSpecify APPLICATION TO CONSTRUCT, REPAIR,RENOVATE,CHANGE THE USE OR OCCUPANCY OF,OR DEMOLISH ANY BUILDING OTHER THAN A ONE OR TWO FAMILY DWELLING ///J SECTION 1 -SITE INFORMATION Gll/r-I �^ / /11�J 1.1 Property Address: This section to be completed by officep a Me.n Sr. _ Map NC Lot Q 1 Cif Unit /t/O RreA.1Jiav ) MA d/M) Zone Overlay District -- --- - - - -- Elm SL District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Ow er of Recorl Name tU� nnt) Current Mailing Address 9 r� 2 � ( Signature Telephone 2.2 An n ed A e 4'l'r� I L r a D. Name(Pont) Cu21- Address rre O ,f •i/r/( D. B (O6U sig �C Telephone qt 5 31 .1D 3 SECTION 3-ESTIMATED CONST CTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by peunit applicant 1. Building �6 10 (a)Building Permit Fee 2. Electrical SOfl (b)Estimated Total Cost of 7s .SOC Construction from 6 3. Plumbing /o11 sO t7 Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total=(1 +2+3+4+5) 500 Check Number This Section For Official Use Only Building Permit Number Dale Issued Signature: Building Commissioner/Inspector of Buildings Date Version L7 Commercial Building Permit May 15,2000 SECTION 4 CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC FEET OF ENCLOSED SPACE D" Accessory Alterations El Existing Wall Signs E DemL7olition❑ Repairs Additions Accessory Building❑ Exterior Alteration ❑ Existing Ground Sign R New Signs❑ Roofing[I Change of Use❑ Other ❑ Brief Description !Enter a brief description here. / Of Proposed Work: y�/2rort f, �9lhrsoayr (4,4// ') x'j 7d —7 14r4SECTION 5-USE GROUP AND CONSTRUCTION TYPE USE GROUP(Check as applicable) CONSTRUCTION TYPE A Assembly A-1 ❑ A-2 ZU A-3 ❑ 1A ❑ A-4 ❑ A-5 1B ❑ B Business %q' /// —B 2A ❑ E Educational ❑ 2B ❑ F Factory ❑ F-1 ❑ F-2 ❑ 2C ❑ H High Hazard ❑ 3A ❑ I Institutional ❑ 1-1 ❑ 1-2 ❑ 1-3 ❑ 3B M Mercantile ❑ 4 ❑ R Residential ❑ R-1 ❑ R-2 ❑ R-3 ❑ 5A ❑ S Storage ❑ S-1 ❑ S-2 ❑ 5B ❑ U Utility ❑ Specify: _. .. .. . _ M Mixed Use ❑ Specify: .,..._ S Special Use ❑ Specify: '.. COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS,ADDITIONS AND/OR CHANGE IN USE Existing Use Group: ___. _. . _. Proposed Use Group: Existing Hazard Index 780 CMR 34):.. . _._ _ Proposed Hazard Index 780 CMR 34): SECTION B BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY Floor Area per Floor(st) //ios� ti 1 ,�2rf^raNr S$o F J 2^' /71 Yic4R .. _. ��� ?• 2^e fi�Vz /�85 4 1 P 3rd 4e _ 4m Total Area(sf) a.") 57 Total Proposed New Construction(sf) ?,33S Total Height(ft) /exd O. Total Height ft 7.Water pply(M.G.L.c.40,§54) 7.1 Flood Zone Information: 7.3 Sewage Posed System: Public am Private ❑ Zone' Outside Flood Zone[ Municipal �On site disposal system❑ Version L7 Commercial Building Permit May 15,2000 8. NORTHAMPTON ZONING Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage 3� . . Setbacks Front Side L R:11- L:.._. R: Rear Building Heigh[ �3r Bldg.Square Footage - -_-- Open Space Footage % (Lot area minus bldg&paved - kin d #of Parkin o Spaces Fill: .. Q. .mnme&L«acon A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DONT KNOW O YES Q IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DONT KNOW O YES O IF YES: enter Book Page! and/or Document N. B. Does the site contain a brook, body of water or wetlands? NO Q-DONT KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained © , Date Issued: C. Do any signs exist on the property? YES (2� NO O IF YES, describe size, type and location: l`rSCY1 'ft RAi' .Qgo✓t tva.wya.r. D. Are there any proposed changes to or additions of signs intended for the property? YES © NO Q IF YES, describe size, type and location: E. Will the construction activity disturb(Gearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES © NO a IF YES,then a Northampton Stoml Water Management Permit from the DPW is required. Verslovil.7 Covvmmisl Building Pamir May 15,4000 SECTION 10-STRUCTURAL PEER REVIEW(190 CMR 110.11) 1 kidsperldent Structural *rWw Struckenal ParRvAaw Required Y. No 0 SECTION 11 OWNER MAUT"ORIZKTION-TOM COMPLETED BR EN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT L as Omer of the wMed prop" hereby authorize to act on d by this biAdng P—It applastion #I:vxt:7 a ret; ------- Ons LP uOmadAMhedzed Agent hereby declare that Na slidernards and InforrmIlDn on the foregoing applicatton an true and socurate,to the beat Of MY MWAIN190 and bekE Sir" pridlime SECTION 14-CONSTRUCTION SERVICES 110.1 Liamod Constr"ll"SILAINIM"r. NotApplicable ❑ Ucense NmW Owa _%3,�_ 7bfsc_ 71 -/7/ Teavilon, SECTION 1S-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.o.152,1 2SC(l)) Workers Con"reatiDn Insurance aMdawk nnust be carnplated and subrrAted with this appifoallon.Fallum to Provide 11110 In the Serial of Ila Issuance,«Sr emit. Signed Arid"Allached Yet No The Commonwealth of Massachusetts Department of Industrial Accidents 7 Congress Street,Suite Boston,MA 02114-2017 www.massgov/dia V11furkers'Campensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Infrmation Please Print Legibly Name(Business/Organirstion/Individmi): ACh. A Address: Ivy G-c9ae�fi rV C City/State/Zip: Cf/.c o xrt cD/�o X I Phone#: `7/y- Soo - 7060 Are you an employer?Check the appropriate box: Type of project(required): I.E24m a employer with / PI7employees(full aMlor parttime).. 7. [.]'New construction 2.❑lemesole proprietor or partnership and have no employees working hansom 8. [g/Remodeling a nycapacity.[Nowmkmx cmnp.insurance required] 3.❑I am a homeowner doing all work myself Mo workm'comp.insurance required.]' 9. Demolition 4❑I am a homeowner and will be hiring contractors to conduct all work on my property. 1 will 10❑Building addition ensure that all contractors either have workers'compensation maummen a are sole 11.[ffElectrlcal repairs or additions propmetots with no employees 12.[tg'Plumbing repairs or additions 5 O 1 am a general contractor and I have hired the sub-contractors listed on the attached short 13.0 Roof repairs These subcontractors have employees end have workers'comp.insurance. 6.❑we arc a corporation and its officers have exercised their right of exemption per MGL c. 14.❑Other 152,§I(4),and we have no employees.(No workers camp.connote required.] Any applicant that checks box 41 most also Fill ouuhe section below showing their workers'compensation policy information. t Homeowners who submit his affidavit indicating they are doing all work and then hire outside contractors most sobmit a new affidavit indicating such. lContracton that check this box must attached an additional sheet showing the name of the subcontractors and state whether or not hose entities have employees. Ifthe subcontractors have employes,they must provide their workers omp.policy number. I am an employer that is providing woryers'compemaaon insurance for my employees. Below is the polity and job site information. ,yi- M 6ay1ZC( �,— Insurance Company Name: tG Policy#or Self-ins.Liic.#: �' r V tet Expiration Date: 6/S/aa 9 Job Site Address: a� MAry ?1 --R----2 ✓ City/State/Zip: 01040 Attach a copy of the workers'compensation policy dedar 'on page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby cc der the pains and penaaies ofperjury that the information provided above is true and correct. Sturman: �Nlflyz Date Ph #' 7 �bD -706n Oficial use only. Do not write in this area,to be completed by city or town official. City or Towa: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: City of Northampton 212 Main Street,Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. Address of the work: �? Mme, �'T• , y� M/9 The debris will be transported by: jell iz The debris will be received by: �n✓F lt�ack/s s /RwkiNq Building permit number: / Name of Permit Applicant �✓°yam �Jd�dN �� Date Signature of Permit Applicant City of Northampton Massachusetts L 282dH.'@SNT OF BUS LDSI ZBSPSCTZ�I& 212 )lain St t a 16avicipal Badding Nomthiapt. HA 01060 Louis Hasbrouck Fax 413-587-1272 Chuck Miller Building Commissioner Phone 413-587-1240 Assistant Commissioner CONSTRUCTION CONTROL DOCUMENT (Fm piefeaaihn8l E Arctdtects resPonai6b for EMiry filyir ) Project Title VnkWama Raollk, Date 'O�2'' 2018 Project Location. 86 Ma'"sr`aca.rioreisnpto MA Map. 3Y Par;el cfe Zane o Scope of Project lorr"aagn of an existing au,vpe u for the use of a new matauraw to accordance with the Eighth edition Massachusetts State Building Code 780 CMR Section 107 6. 1 JO 'earxe.A 4 Mass Registration'# 50385 Being a registered professional Engineer,Archited hereby CERTIFIES that I have prepared or directly supervised the preparation of all design plans, computations and spedfications concerning. [A ENTIRE PROJECT For the above named project and that to the best of my knowledge such plans.. computations and specs icauons meet the applicable provisions of the Massachusetts State Building Codeall acceptable engineering practices and all applicable Laws for the proposed project. Furthermore. I understand and AGREE that I shall perform the necessary professional services to determine that the above mentioned portions of the work proceed in accordance with the documents approved for the building permit and shall be responsible for the folowino as specified in Section 10.7.8.2.2 1. Review of shop drawingswrtskes and other submittals of the contractor as required by the construction documents as submitted for the building permit and approval for the conforcnance to the design concept. 2. Review and approval of the quality control procedures for all code-required controlled materials 1. Be present at intervals appropriate to the stage of construcbon to become generally familiar with the progress and quality of the work and to determine in general. rf the work is being performed In a matter consistent with the construction documents I Shall submit periodically, in a form acceptable to the building official. a progress report together with pertinent Comments. Upon completion of the work. I shall submit to the building official a final report as to the satisfactory oompleuari and readiness of the project for occupancy. �xEuf k Signature and Seal of Registered Professional .,A Irw JWy Barter AIA r'— 21 Day of .lune 2p to ,. Y' Quote 01/12/2018 To: Project: From: Yokohama Ramen Yokohama Ramen-Andy JFK Restaurant Equipment Supply Andy 55 Canal Street 88 Main Street NEW YORK, NY 10002-5304 Northampton, MA 01060 646-613-1898 (Contact) 203-232-7252 (Contact) Job Reference Number.306 Item Qty Description 1 3 ea ELECTRIC FLOOR FRYER Model No. IFS-40-E Fryer, electric,floor model,401b.capacity, immersed electrical elements,snap action thermostat, Includes: wire mesh crumb screen &(2) nickel-plated baskets, stainless steel front, door, sides, basket hanger&frypot, 6" legs, 14.0 kW, cETLus,CSA-Sanitation,CE 3 ea Limited one year parts and labor warranty,standard 3 ea 208v/60/3-ph,39.0 amps, 14.0 kW,standard ITEM TOTAL: $4,950.00 2 2 ea STOCK POT RANGE,18",2 COIL ELEMENTS Model No. ISPA-18-2-E ® Stock Pot Range, electric, 18", (2)coil elements,Independently t controlled coils, infinite heat control,open front cabinet, bottom \( shelf,stainless steel top,front, sides &cabinet,6" legs, adjustable * feet, cETLus,ETL-Sanitation 2 ea Limited one year parts and labor warranty,standard 2 ea 208v/3-ph,12.0 kW,44.0 amps,standard ITEM TOTAL: $5,570.00 3 1 ea RANGE,36",6 ROUND SOLID BURNERS Model No. M-6-E IMRestaurant Range,electric, 36", (6) round elements,solid top, standard oven, (1) chrome rack, splatter screen, infinite heat controls, porcelain oven interior, stainless steel front, sides, backguard, landing ledge & kick plate, 6" legs,adjustable feet, cETLus, ETL-Sanitation,CE 1 ea Limited one year parts and labor warranty,standard 1 ea 208v/60/1-ph,84.0 amps, 17.3 kW,standard 1 ea Stainless steel backguard with shelf standard ITEM TOTAL: $2,150.00 4 lea MEGA TOP SANDWICH/SALAD PREPARATION REFRIGERATOR Model No. BST-60-24 Mega Top Sandwich Unit,two-section, 18.6 cu.ft., rear mounted self- contained refrigeration, self closing stainless steel door,(2) adjustable plastic coated steel shelves, (24) 1/6 size pan capacity,thermostat ' temperature control,430 stainless steel exterior and 304 stainless steel Interior, (4)casters (2 front locking), R134A refrigerant, 1/2 HP, Yokohama Ramen-Andy Yokohama Ramen Page 1 of 3 JFK Restaurant Equipment Supply 01/11/1018 Item Qty Description r- 115v/60/1,NEMA 5-15P,cETLus,NSF 1 ea 1 Year parts&labor, 5 year compressor warranty, standard ITEM TOTAL: $1,625.00 5 lea WORKTABLE Model No.SG-3036 S� o,S/G 30'X36"WORK TABLE ITEM TOTAL: $100.00 6 lea WORKTABLE Model No.SG-3060 -Z o,S/G 30"X60"WORK TABLE ITEM TOTAL: $135.00 7 2e OVERSHELF,TABLE-MOUNTED Model No. DOS-1860 'rkP ,DOUBLE OVER SHELF 18"H 60"SS ITEMTOTAL: $300.00 8 1 as SINK,(3)THREE COMPARTMENT Model No. 2424-3DB 120' L Three Compartment Sink, Bowl 24"x24"With 2 Drain Bowl ITEM TOTAL: $725.00 9 2 ea WALL/SPLASH MOUNT FAUCET Model No. 14-812L Krowne Royal Series Faucet, splash mount,8" centers, 12"swing r - -4.0 spout, low lead compliant, NSF 2 ea 1 year parts &labor warranty, standard ITEM TOTAL: $190.00 10 1 ea DISHTABLE,CLEAN STRAIGHT Model No. DCT-3L $ift, DISHTABLE CLEAN, LEFT,30" ITEM TOTAL: $295.00 11 lea DISHTABLE,SOILED Madel No. DST-60R i5c5ih11.o(fly, o5i)j,DISHTABLE SOILED, RIGHT,60" ITEM TOTAL: $600.00 12 1 ea ICE CUBER WITH BIN Model No. UD-0190A NEO" Undercounter Ice Maker, cube-style,air-cooled,self contained, 26"W x 28"D x 38-1/2"H, production capacity up to 198 lb/24 hours at 70°/50°(140 IS AHRI certified at 90°/70"),90 lb ice storage capacity, electronic controls,dice size cubes, NSF, cETLus, ENERGY STAR® lea WARRANTY-ICE-SC 3 year parts&labor(Machine), 5 year parts& labor (Evaporator(,5 year parts (Compressor),standard 1 ea (-161) 115v/60/1-ph, 6.0 amps,cord with NEMA 5-15P ITEMTOTAL: $1,795.00 13 2 ea SINK,HAND Madel No. H53-1715 Yokohama Ramen-Andy Yokohama Ramen Page 2 of 3 JFK Restaurant Equipment Supply 01/11/1018 Item Qty Description Wall Mounted Hand Sink With SideSplash ITEM TOTAL: $190.00 14 l ea MOP SINK Model No. MS-2424 # Lp , MOP SINK, PLASTIC ITEM TOTAL: $195.00 15 2e ADAPTER PLATE Model No.ADAPTER Heavy gauge 5 HOLE ADAPTER 5-1/4" ID, FOR PASTA COOKER ITEM TOTAL: $300.00 16 lea CABINET Model No. C-60 Cabinet 60"x30" ITEM TOTAL: $625.00 Merchandise $19,745.00 Tax 8.875% $1,752.37 Total $21,497.37 Thank You For Your Business Remarks: No Refund, All Equipment has standard mfg.warranty. 50%Deposit, Balance Is Due At Time Of Pick-Up Or Before Delivery. All Returns are subject to a 25%restocking fee plus any freight charges.Unused merchandise returned with the original pack within 7 days of purchases with original receipt will be exchange or store credit only. All parts&custorn items&special order no cancellations or returns or exchange. All Deliveries Are Tailgate Only.And Plus Freight Charges. *****Extra 3%Sub-Charge For Pay By Credit Card***** Yokohama Ramen-Andy Yokohama Ramen Page 3 of 3 } �.�..._.�...___...�: - _ W:�-- s rp }i �' m � � �_ � N �� s� a � - ��ll"F�� � 0. � _ ��� �f � � �� - --- --.�^ -A d 9SC.( �£.4 — c`z� flJj�-� —��'� `� l6 7✓fU "?r�x1�`if� � o s Jill In Page 1 of 4 Thanks John. j Please see attached and let me know if you have any questions. (ALL 1.866.431.8335 aaaaaal VIIIILATIINIIIIII,1011 Ventilation:Direct YOUR DIRECT SOURCE FOR VENTILATION PRODUCTS Thursday, May 31, Quote#: 3427386 Xiu Zhen Li 2018 To: From: Ship-To: William Bridges Xiu Zhen Li Ventilation Direct 88 Main Street 14460 New Falls of Neuse Rd NORTHAMPTON, MA 01060 Suite 149-293 Raleigh, NC 27614 Local: (919) 573-1522 Toll Free: (866)433-8335 Fax: (919) 573-1523 infoCEDventi lationdi rect.com C Ventilation Direct proposes to fumish the following equipment.Production of listed items will commence upon receipt of an approved proposal,a purchase order,an approved submittal,and approved credit. EQUIPMENT Hood#1 -Job#3427386 5424W-2-PSP-F-15ft 0"Long Exhaust-Only Wall Canopy Hood with Front Perforated Supply Plenum with x1 Built-in 3"Back Standoff -430 SS Where Exposed x1 -Utility Cabinet on the Left Side 12.00"Width x 54.00"Length x 24,00"Height A -FILTER-16"tall x 16"wide Kleen-Gard Stainless Steel Baffle Filter with Handles and Bottom Hanging x11 Hook,UL Classified -L55 Series E26 Canopy Light Fixture-High Temp Assembly,Includes Clear Thermal and Shock x5 Resistant Globe(1-55 Fixture),Bulbs By Others -EXHAUST RISER-Factory installed 14"Diameter X 4"Height x2 -SUPPLY RISER-12"x 28"Supply Riser with Volume Dampers x4 -112 Pint Grease Cup New Style,Flanged Slotted x2 -FIELD WRAPPER 26.00'High Front,Left x1 -Electrical Package Installation in Utility Cabinet by Plant x1 -BACKSPLASH 80.00"High X 193.00"Long 430 SS Vertical(Includes End Caps&Divider Bars) x1 -RIGHT END STANDOFF 1"Wide 54"Long Insulated xi -RIGHT SIDESPLASH 80.00"High X 54.00'Long 430 SS Vertical(Includes End Caps&Divider Bars) x1 -INSULATION FOR BACK OF HOOD x1 Hood#1 Total Prlca: $5,088.09 Fire System#1 *FINAL HOOK UP,TESTS and PERMITS NOT INCLUDED'-Job#3427386 https://3c-lxa.mail.com/mail/client/mailbody/tmai1533c592411c715a/true 5/31/2018 Page 3 of 4 -Thermistor CABLE-162 AWG GREEN WH ITE,plenum rated.USED for thermistor dud stat Per Foot x50 Price. CElectrical System#1 Total Price: $1,003.75 Duct Run#1 (Pi)DW1445ASY Single Wall Dud 45 Degree Elbow, 14"Dud,Assembly, xi (P2)DW1445ASY Single Wall Dud 45 Degree Elbow, 14"Dud,Assembly. xi (P3)DW1435LT Single Wall Dud 14"diameter,35"long,flange at both ends.Stainless Steel. xi (P4)DW144WDKIT Single Wall Dud Adjustable, 14"diameter,4T5"long,flange at one end With a 14" xi Adjustable Collar-Stainless Steel. (PS)DM42514TP Dud to Curb Transition,2425"Curb to 14"Dud,16 GA Aluminized.Misc. non- xi standard transition plate. (P6)DW1445ASY Single Wall Dud 45 Degree Elbow, 14"Dud,Assembly. xi (P7)DW1445ASY Single Wall Dud 45 Degree Elbow, 14"Duct,Assembly. x1 (PB)DW1435LT Single Wall Dud 14"diameter,35"long,flange at both ends.Stainless Steel. xi (P9)DW1448AJDKIT Single Wall Dud Adjustable, 14"diameter,47.5"long,flange at one end With a 14" xi Adjustable Collar-Stainless Steel. (P10)DM42514TP Duct to Curb Transition,24.25"Curb to 14"Dud, 16 GA Aluminized.Misc.non- xl standard transition plate. 3M-2000PLUS Dud-3M Fire Barrier 2000 Plus Silicone-Used as sealant to Seal Dud Joints. x2 DW14CLASY Duct'V'Clamp With new design 14 Ga Brackets, 14"Dud,Assembly. x8 Duct Run#1 Total Price: $943.72 Subtotal: $14.53646 Shipping: Freight lnduded Tax: Not Included CTotal: USD$14,536.46 Ventilation Direct . . . . . . .. . .. ... ... ... . . . . . . . . . . . . . . . .. . . . . . . . . . Will Bridges Technical Sales p 866.433.8335 p 919.573.1522 1 f 919.573.1523 ventilationdirectcom From:John Kosakowski <acheva@mail.com> Date:Thursday, May 31, 2018 at 11:00 AM To: William Bridges<william.bridges@ventilationdirect.com> Subject: Re: <no subject> Sent: Thursday, May 31, 2018 at 10:46 AM From: "William Bridges" <william.bridges@ventilationdirect.com> To: "acheva@mail.com" <acheva@mail.com> Subject: <no subject> L Ventilation Direct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Will Bridges I Technical Sales https://3c-lxa.mail.com/mail/client/mailbody/tmail 533c592411 c715a/true 5/31/2018 Page 2 of 4 ANSUL-3.013.0-MANIFOLD Ansul 6 gallon Manifolded Wall Mounted Fire System(includes pre-piped hood A (s)and detection). Includes piping for hood. 1. Fire System#1 Total Price: 81,11535 Fan#1 VXD85-Exhaust Fan-Job#3427386 VXD85 High Speed Direct Drive Centrifugal Upblast Exhaust Fan with speed control(speed control x1 included for single phase only),disconnect switch and 15-3/4"wheel. Exhaust Fan handles 1875 CFM @-0,700"we ESP.Fan runs at 1247 RPM. Exhaust Motor:0 750 HE 1 Phs, 115 V,601-1z,9.8 FLA,ODP(Open Drip Proof) -Grease Cup for kitchen-duty centrifugal exhaust fans,Box Dimensions 17-1/8 L X 5-1/16 W X 3-3/4 H(18 xi GA.)(Includes Down Spout) -Curb CRB23X20E On Fan#1 Flat Curb xi -Hinged Base for Curb.Standard Hinge attached to curb.Used on Fans with wheels 20 inches or smaller. xi 12 GA Galvanized. -Vented Base for Curb xi Fan Total Price: 8760.36 Fan#2 VXD85-Exhaust Fan-Job NU27386 VXD85 High Speed Direct Drive Centrifugal Upblast Exhaust Fan with speed control(speed control xi induced for single phase only),disconnect switch and 15-3/4"wheel. Exhaust Fan handles 1875 CFM @-0,700"we ESP,Fan runs at 1247 RPM, Exhaust Motor:0.750 HP,1 Phs, 115 V,6011z.9.8 FLA,ODP(Open Drip Prool) -Grease Cup for kilchenduty,centrifugal exhaust fans,Box Dimensions 17-118 L X 5-1/16 W X 3-314 H in x1 GA.)(includes Dawn Spout) -Curb CRB23X20E On Fan#2 Flat Curb xt -Hinged Base for Curb.Standard Hinge attached to curb. Used on Fans with wheels 20 inches or smaller. x1 12 GA Galvanized. Vented Base for Curb x1 Fan Total Price: 8760.36 Fan#3 V2D.250-Gifi-Heater-Job#3427386 V2D.250-G15 Direct Gas Fired Heated Make Up Air Unit with 15"Blazer xt Supply Fan handles 3000 CFM @ 0 400"we ESP,Fan runs at 741 RPM. Heater supplies 202575 BTUs,65-F Temperature Rise.(Fuel:Natural Gas] Supply Motor: 1.500 HP, 1 Phase,115 V,60Hz, 13.6 FIA.ODP(Open Drip Proot) Down Discharge-Air Flow Right->Left -Sloped Filtered Intake for Sae#2 Modular Heater,26.813"Wide X 53.625"Long X 31.313"High.InGutles x1 2"MV EZ Kleen Metal Mesh Filters. -RTC Solutions"40-90"F Discharge Temp Control x1 -Gas Manifold for DF2 GM-BTU 0-825001 -7 in.w c.-14 in.w.c.,No Insurance Requirement(ANSI), A BV250-88 -Cooling Interlock Relay.24VAC Coil. 120V Contacts.Locks out burner circuit when AC is energized. x1 -Motorized Back Draft Damper 22.75"X 24"for Sae 2 Standard 8 Modular Heater Units w/Extended Shaft, x1 Standard Galvanized Construction,3/4"Rear Flange,Low Leakage, LF120S Actuator Included -Low Fire Start.Allows lite burner circuit to energize when the modulation control is in a law fire position. x1 -Gas Pressure Gauge,0-35",2.5"Diameter,1/4"Thread Size x1 -Gas Pressure Gauge,-510♦15 Inches Wc.,2.5"Diameter,1/4"Thread Size A -Curb CRB31X79X20INS Insulated On Fan#3 Flat Curb x1 Fan Total Price: 84,864.93 Electrical System#1 -Job#3427386 SC-121110FP 120V 1 Phase w/control for 2 Exhaust Fans, 1 Supply Fan,Exhaust on in Fire,Lights out in x1 r/ Fire Farts)OrVOH Thermostatically Controlled.Room temperature sensor shipped loose for field installation.Includes 2 Dud Thermostat kits. -Digital Prewire Lighting Relay Kt.Includes hood lighting relay 8 terminal blocks.Allows for up to 140OW x1 of lighting each. https://3c-lxa.mail.com/mail/client/mailbody/tmail533c592411015ahrue 5/31/2018 Page 1 of 4 Thanks John. Please see attached and let me know if you have any questions. CALL 1866.433.833S VENTILATIONDIRECT.COM Ve 1datbi(1ciDi ed YOUR DIRECT SOURCE FOR VENTILATION PRODUCTS Thursday, May 31, Quote#: 3427386 Xiu Zhen Li 2016 To: From: Ship-To: William Bridges Xiu Zhen Li Ventilation Direct 88 Main Street 14460 New Falls of Neuse Rd NORTHAMPTON, MA 01060 Suite 149-293 Raleigh, NC 27614 Local: (919) 573-1522 Toll Free: (866)433-8335 Fax: (919) 573-1523 Infoaventilationd i rect.com Ventilation Direct proposes to furnish the fallowing equipment. Production of listed items will commence upon receipt of an approved proposal,a purchase order,an approved submittal,and approved credit. EQUIPMENT Hoed#1-Job#3427386 5424VX-2-PSP-F-15tt 0"Long Exhaust-Only Wall Canopy Hood with Front Perforated Supply Plenum with x1 Built-in 3"Back Standoff -430 SS Where Exposed xt -Utility Cabinet on the Left Side 12.00'Width x 54.00"Length x 24.00"Height xt -FILTER-16"tall x 16"wide Kleen-Gard Stainless Steel Baffle Filter with Handles and Bottom Hanging x11 Hook,UL Classified -L55 Series E26 Canopy Light Fixture-High Temp Assembly,Includes Clear Thermal and Shock x5 Resistant Globe(L55 Future),Bulbs By Others EXHAUST RISER-Factory installed 14"Diameter X 4"Height X2 -SUPPLY RISER-12"x 28"Supply Riser with Volume Dampers x4 -1¢Pint Grease Cup New Style, Flanged Slotted x2 -FIELD WRAPPER 26.00"High Front,Left xi -Electrical Package installation in Utility Cabinet by Plant. x1 -BACKSPLASH 80.00"High X 193.00"Long 430 SS Vertical(includes End Caps 8 Divider Bars) xi -RIGHT END STANDOFF 1"Wide 54"Long Insulated x1 -RIGHT SIDESPLASH 80.00'High X 54.00"Long 430 SS Vertical flndudes End Caps 8 Divider Bars) A C -INSULATION FOR BACK OF HOOD xi Hood 01 Total Price: 65,088.08 Fire System#1 'FINAL HOOK UP,TESTS and PERMITS NOT INCLUDED'-Job 93427386 https:H3c-lxa.mail.com/mail/client/mailbody/tmai1533c59241lc715a/true 5/31/2018